36C24218B0125-011.pdf
PDF 20 MB Posted
- Attached to
- Renovate 6C for Mental Health
- Solicitation number
- 36C24218B0125
About this file
36C24218B0125 S02 - 526-13-102 Mental Health FULL BID SET Drawings.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24219C0071-001.docx | DOCX document | |
| 36C24218B0125-0005000.docx | DOCX document | |
| 36C24218B0125-0004000.docx | DOCX document | |
| 36C24218B0125-0004001.pdf | ||
| 36C24218B0125-0004002.pdf | ||
| 36C24218B0125-0003001.pdf | ||
| 36C24218B0125-0003003.pdf | ||
| 36C24218B0125-0003002.pdf | ||
| 36C24218B0125-0003000.docx | DOCX document | |
| 36C24218B0125-0002000.docx | DOCX document | |
| 36C24218B0125-0001000.docx | DOCX document | |
| 36C24218B0125-012.zip | ZIP file | |
| 36C24218B0125-010.docx | DOCX document | |
| 36C24218B0125-013.docx | DOCX document | |
| 36C24218B0125-000.docx | DOCX document |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WEBB AVENUE
S E
D G
W
IC
K
A
V
E
N
U
E
K I N
G S
B R
I D
G E
R O
A D
SCALE:
" = 1'-0"
FLOOR TILE, MASTIC, AND CARPET TO BE REMOVED.
FLOOR TILE, MASTIC, AND WOOD FLOOR TO BE REMOVED.
FLOOR TILE, MASTIC, AND RUBBER FLOOR TO BE REMOVED.
FLOOR TILE, AND MASTIC TO BE REMOVED.
FLOOR TILE, MASTIC, AND LINOLEUM TO BE REMOVED.
HEPA - FILTERED NEGATIVE AIR MACHINE.
1. Asbestos abatement shall be performed in accordance with the specification and applicable regulations. Personnel holding current New
York State Department of Labor (NYSDOL) and New York City
Department of Environmental Protection (NYCDEP) asbestos handler's certificates shall perform the work. Additionally, the Contractor must employ NYSDOL and NYCDEP certified supervisors to be on the work site for all abatement activities. The contractor must be currently licensed by the NYSDOL. All certificates and licenses are to be readily available for verification by the Veterans Affairs Medical Center.
2. Contractor is responsible for removal and disposal of all asbestos-containing materials and asbestos-contaminated materials within the specified areas.
2. Contractor is responsible for verification of all quantities of asbestos-containing materials.
3. Contractor is responsible for precleaning any existing asbestos contamination, dust and debris within the removal areas.
4. Contractor is responsible for maintaining the integrity of building finishes.
The contractor shall repair any and all damages caused by abatement activities or his personnel.
5. Contractor is solely responsible for all means, methods, techniques, sequences and procedures and for coordinating all portions of the scope of work under this contract.
6. The project shall be filed as a large project with the NYSDOL.
1. A significant portion of the sixth (6th) floor is undergoing a renovation.
Asbestos-containing materials (ACM's) must be removed to allow for the renovation. ACM's include but are not limited to floor tile and mastic.
There are areas where there is carpet, wood, rubber and/or linoleum covering the floor tile. These materials (carpet, wood, rubber and/or linoleum) will also be removed and disposed of as ACM because it is contaminated by the floor tile.
2. The contractor shall construct personal and waste decontamination units outside the work areas for use in asbestos abatement. The decontamination units shall be located contiguous to the 6th floor work area and not remote.
3. The asbestos abatement shall be coordinated to avoid interruptions to the normal activities of the V.A., which may include off hours work
4. All asbestos-containing materials within the contract limits must be removed and disposed of as asbestos-contaminated waste unless specifically excluded in these specifications or on the drawings. The contractor shall remove all walls to access the underlying floor tile.
5. All ACM's shall be removed in accordance with New York State
Department of Labor (NYSDOL) Industrial Code Rule 56 (12 NYCRR 56) and applicable Federal OSHA and EPA regulations. Where there is an overlap the most stringent regulation shall apply.
6. All work area decontamination units (personal and waste) shall be fully framed and sheathed because they will be located in areas of public access.
7. All utilities, mechanical systems and piping shall be locked out and tagged before the contractor is to begin abatement activities.
F
LEAF TYPES
FR 1
FRAME TYPES
FR 2
DOOR SCHEDULE
FG FG2 HG
FR 3 FR 4
F-1
DOOR SCHEDULE
FR 5
F-2V F-V PRA RAGHG2 HG3
FR 6
HG2A HG3A
WINDOW SCHEDULE
GENERAL NOTES:
1. ALL PIPING AND DUCTWORK SHALL BE HUNG FROM BUILDING STRUCTURE ONLY, EXCEPT AS
SPECIFICALLY ALLOWED IN THE SPECIFICATIONS. HVAC CONTRACTOR SHALL PROVIDE
SUPPLEMENTARY STEEL AS NECESSARY TO SUPPORT PIPES AND DUCTS FROM BUILDING
STRUCTURE. THE ARCHITECT AND STRUCTURAL ENGINEER SHALL BE THE SOLE DETERMINANT AS
TO PERMISSIBILITY OF HANGING NEW WORK FROM BUILDING STRUCTURE AND SLABS.
2. PIPING AND DUCTWORK SHALL BE COORDINATED WITH WORK BEING PROVIDED BY OTHER
TRADES.
3. FINAL LOCATION OF ALL CEILING DIFFUSERS, RETURN REGISTERS AND CEILING GRILLES SHALL BE
AS SHOWN ON THE ARCHITECTURAL REFLECTED CEILING PLANS. THE CONTRACTOR SHALL
PROVIDE DUCTWORK AS REQUIRED TO COMPLY WITH THIS. QUANTITIES OF THESE DEVICES SHALL
BE PROVIDED AS SHOWN ON THE "MH" DRAWINGS. ANY DISCREPANCIES BETWEEN THE "MH"
DRAWINGS AND THE ARCHITECTURAL REFLECTED CEILING PLANS SHALL BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT FOR RESOLUTION PRIOR TO BID.
4. WHILE THE DRAWINGS SHALL BE ADHERED TO AS CLOSELY AS POSSIBLE, THE ARCHITECT'S RIGHT
IS RESERVED TO VARY THE RUN AND SIZE OF DUCTS DURING THE PROGRESS OF THE WORK IF
REQUIRED TO MEET CEILING HEIGHTS, TO MEET STRUCTURAL AND FIELD CONDITIONS.
CONTRACTOR SHALL PROVIDE REDRAWING OF SHOP DRAWINGS AS NECESSARY TO
ACCOMMODATE THE ARCHITECT'S REQUIREMENTS, AT NO ADDITIONAL COST TO THE
GOVERNMENT. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR REQUIRED CEILING
HEIGHTS.
5. INSTALL ALL DUCTWORK IN STRICT ADHERENCE TO THE CEILING HEIGHTS INDICATED ON THE
ARCHITECT'S DRAWINGS. CONSULT WITH OTHER CONTRACTORS AND IN CONJUNCTION WITH THE
OTHER CONTRACTORS, ESTABLISH THE NECESSARY SPACE REQUIREMENTS FOR EACH TRADE.
6. THE SHEET METAL DUCTWORK SHALL, WHETHER INDICATED OR NOT, RISE AND/OR DROP AND/OR CHANGE IN SHAPE TO CLEAR ANY AND ALL OTHER DUCTWORK, CONDUITS, LIGHTING FIXTURES, PLUMBING AND HEATING MAINS TO MAINTAIN THE DESIRED CEILING HEIGHTS AND TO PROVIDE
ADEQUATE MAINTENANCE ROOM AND HEADROOM IN MECHANICAL EQUIPMENT ROOMS. THE
DRAWINGS, IN GENERAL, DO NOT SHOW ALL RISES, DROPS AND DUCT TRANSITIONS REQUIRED.
THE DRAWINGS SHOW GENERAL ROUTING REQUIREMENTS ONLY.
7. THE DUCTWORK SHALL BE CONTINUOUS, WITH AIRTIGHT JOINTS AND SEAMS PRESENTING A
SMOOTH SURFACE ON THE INSIDE AND NEATLY FINISHED ON THE OUTSIDE. DUCTS SHALL BE
CONSTRUCTED WITH CURVES AND BENDS SO AS TO EFFECT AN EASY FLOW OF AIR. UNLESS
OTHERWISE SHOWN ON THE DRAWINGS, THE INSIDE RADIUS OF ALL CURVES AND BENDS SHALL
BE NOT LESS THAN WIDTH OF DUCTS IN PLANE OF BEND.
8. ALL RECTANGULAR DUCTWORK, UNLESS OTHERWISE NOTED, SHALL BE BUILT FROM GALVANIZED
SHEET STEEL AND THOROUGHLY BRACED AND STIFFENED. SEE SPECIFICATIONS FOR DUCTS
REQUIRED TO BE FABRICATED OF ALUMINUM AND STAINLESS STEEL.
9. PROVIDE 12" x 12" ACCESS DOORS EVERY 50'-0" RUN OF SUPPLY AND RETURN AIR DUCT FOR CLEANING PURPOSES, EXCEPT IN DUCT ABOVE SOUND CONTROL CEILING. PROVIDE 18" x 18"
ACCESS DOORS, AT EACH FIRE AND FIRE/SMOKE DAMPER, AT EACH MOTORIZED DAMPER, AND
WHEREVER ELSE INDICATED IN THE SPECIFICATION. IF THE DUCT IS TOO SMALL TO PROVIDE AN 18" x 18" ACCESS DOOR, A 12" x 12" ACCESS DOOR SHALL BE PROVIDED.
10. SEE SPECIFICATION FOR DUCTS REQUIRED TO BE LINED. ALSO, LINE DUCTS WHERE SPECIFICALLY
INDICATED ON THE PLANS. DIMENSIONS GIVEN ON PLANS FOR LINED DUCTS ARE CLEAR
DIMENSIONS. INCREASE SIZE OF SHEET METAL DUCT TO PROVIDE THE SPECIFIED CLEAR
DIMENSION WITH ACOUSTICAL LINING ADDED.
11. ALL VALVES, DAMPERS, AND OTHER EQUIPMENT LOCATED ABOVE THE CEILING, WHICH REQUIRE
MAINTENANCE, SHALL BE LOCATED SO AS TO PERMIT MAINTENANCE. IN THE HIGH FLOOR TO
FLOOR AREAS, THIS EQUIPMENT SHALL BE LOCATED AS LOW AS POSSIBLE IN THE CEILING CAVITY
FOR EASIER ACCESS. LOCATE SUCH EQUIPMENT ABOVE ACCESSIBLE CEILINGS TO THE EXTENT
POSSIBLE TO AVOID ACCESS DOORS IN THE CEILING.
12. ALL BIDDERS ARE REQUIRED TO REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF ALL
MEP/FP COMPONENTS FOR FULL INTEGRATION INTO ARCHITECTURAL DESIGN. BIDDERS ARE TO
IMMEDIATELY CALL TO THE ARCHITECT'S ATTENTION ANY DISCREPANCIES IN QUANTITIES, TYPES
AND SCOPE FOR ALL DISCIPLINES/TRADES.
13. SEE ARCHITECTURAL REFLECTED CEILING PLAN (RCP), DRAWINGS AND FLOOR PLANS FOR
LOCATION OF ALL CEILING MOUNTED DEVICES. SEE ARCHITECTURAL DRAWINGS FOR LOCATION
OF ALL WALL MOUNTED DEVICES.
14. SYMBOL AND LEGENDS SHOWN ON THE DRAWING ARE FOR MECHANICAL DRAWINGS ONLY. SEE
ARCHITECTURAL DRAWING AND TRADES DRAWINGS FOR RESPECTIVE SYMBOLS AND LEGENDS.
GENERAL DEMOLITION NOTES
1. DEMOLITION WORK SHALL BE PERFORMED BY WORKMEN EXPERIENCED IN THIS TYPE OF WORK AND SHALL BE CARRIED THROUGH TO COMPLETION WITH DUE REGARD TO THE SAFETY OF ALL BUILDING
OCCUPANTS AND THE EMPLOYEES OF THE CONTRACTOR, WITH AS LITTLE DISTURBANCE AS
POSSIBLE.
2. DEMOLITION OF HVAC ITEMS SHALL BE PERFORMED UNDER THE HVAC CONTRACT.
3. PRIOR TO DEMOLITION TEST THE EXISTING AIR DISTRIBUTION, RETURN AND EXHAUST SYSTEMS.
OBTAIN READING OF AIR FLOWS AND STATIC PRESSURES AT DUCT MAINS SERVICING THE SPACE.
SUBMIT TESTING REPORT TO COTR.
4. LOCATION OF THE EXISTING DUCTWORK & PIPING AS SHOWN ON DRAWINGS IS APPROXIMATE.
5. PROVIDE TEMPORARY SUPPORTS WHERE REQUIRED.
6. DURING DEMOLITION, PROPERLY CAP AND PROTECT ALL DUCTWORK, EQUIPMENT, AND PIPING THAT
WILL REMAIN IN OPERATION.
7. WHERE EXISTING INSULATION TO REMAIN IS DAMAGED BY THE REQUIREMENTS OF THE WORK, REPLACE ANY DAMAGED INSULATION TO MATCH EXISTING.
8. DEMOLISH ALL EQUIPMENT AS INDICATED, FIXTURES AND/OR MISCELLANEOUS ARTICLES IN THEIR
ENTIRETY INCLUDING AUXILIARY EQUIPMENT, PIPING, WIRING, CONDUIT AND DUCTWORK.
9. MATERIALS RESULTING FROM THE DEMOLITION OPERATIONS SHALL NOT BE ALLOWED TO
ACCUMULATE ON THE FLOORS AND ROOF SURFACES, EXTERIOR GRADE SURFACES OR OTHER
PARTS OF THE PREMISES, AND SHALL BE PROMPTLY REMOVED AND DISPOSED OF AWAY FROM THE
PREMISES BEFORE 8:00 AM AND AFTER 4:30 PM.
10. INCLUDE ALL DEMOLITION OF SYSTEMS AND COMPONENTS WHERE SYSTEMS SHALL BE REPLACED
BY NEW WORK. REFER TO THE DRAWINGS AND SPECIFICATIONS FOR THE SCOPE OF NEW AND
RECONNECTED WORK. THE INTENT OF THIS REQUIREMENT IS TO HAVE THE CONTRACTOR
DISCONNECT, DEMOLISH AND REMOVE ALL EXPOSED AND CONCEALED WORK WHERE BEING
REPLACED OR CONNECTED TO THE NEW LAYOUTS.
11. PRIOR TO DEMOLITION COORDINATE ELECTRICAL POWER DISCONNECTION WITH ELECTRICAL
CONTRACTOR.
12. PROTECT ALL HVAC WORK AND WORK OF OTHER TRADES WHICH IS TO REMAIN, FROM DAMAGE
DURING DEMOLITION.
13. ALL PIPING AND DUCTWORK TO REMAIN SHALL HAVE ENDS TERMINATED IN A NEAT MANNER READY
FOR CONNECTION OF NEW WORK. ALL EXPOSED ENDS OF PIPING AND DUCTWORK SHALL BE
CAPPED. SCREWED PIPING SHALL END ON A SCREWED JOINT. FLANGED PIPE SHALL END WITH A FLANGED JOINT. WELDED PIPING SHALL BE MECHANICALLY CUT, CLEANED OF BURRS AND A CAP
WELDED TO THE PIPE. DUCTWORK SHALL BE CAPPED WITH SHEET METAL CONNECTED TO THE
DUCT TO REMAIN.
14. REMOVAL OF EQUIPMENT, PIPING AND DUCTWORK SHALL INCLUDE ALL HANGERS & SUPPORT
ASSOCIATED WITH THE EQUIPMENT, PIPING AND DUCTWORK TO BE REMOVED.
LIMIT OF DEMOLITION
SUPPLY DUCT (UP & DOWN)
EXHAUST DUCT (UP & DOWN)
SQUARE 4-WAY CEILING DIFFUSERS
EXHAUST OR RETURN CEILING REGISTER OR GRILLE
VANED ELBOW & AIR SPLIT TYPE DUCT TAKE-OFF
CONNECT NEW DUCT TO EXISTING DUCT
D
INCLINED RISE, IN DIRECTION OF AIR FLOW
INCLINED DROP, IN DIRECTION OF AIR FLOW
R
RETURN DUCT (UP & DOWN)
SQUARE 3-WAY CEILING DIFFUSERS
SQUARE 2-WAY CEILING DIFFUSERS
SQUARE 1-WAY CEILING DIFFUSERS
FC
10x8
FLEXIBLE CONNECTION, EQUIPMENT,
VANED ELBOW (PROVIDE ALL SQUARE OR
RECTANGULAR ELBOWS WITH VANES EVEN IF
SYMBOL IS MISSING)
VANED ELBOW (SHORT RADIUS)
STANDARD RADIUS ELBOW (LONG RADIUS)
NEW DUCT (INSIDE DIMENSIONS: WIDTH x DEPTH)
EXISTING DUCT TO REMAIN
FIRE DAMPER
FD
VD
DUCT WITH SOUND LINING
MANUAL VOLUME DAMPER
REMOVE EXISTING DUCT
VIBRATION, OR SEISMIC
SUPPLY
RETURN45°
RETURN, NO SPLITTER (45° TAP)
STANDARD BRANCH SUPPLY OR
MANUAL SPLITTER DAMPER
45°
N
COMBINATION FIRE/SMOKE DAMPER
AUTOMATIC CONTROL DAMPER (MODULATING)
DUAL DUCT MIXING BOX
CONVECTOR OR RADIATOR
A/E ARCHITECT / ENGINEER
AAV AUTOMATIC AIR VENT
ACCU AIR-COOLED CONDENSING UNIT
ACD AUTOMATIC CONTROL DAMPER, MODULATING
ACD-TP AUTOMATIC CONTROL DAMPER, TWO
POSITION
AD ACCESS DOOR
A.F.F. ABOVE FINISHED FLOOR
AFMD AIR FLOW MEASURING DEVICE
AHU AIR-HANDLING UNIT
AP ACCESS PANEL
APD AIR PRESSURE DROP
ARCH ARCHITECTURAL
ASVD AUTOMATIC SMOKE VENT DAMPER
(MOTOR OPERATED - NORMALLY CLOSED)
BHP BRAKE HORSEPOWER
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNIT PER HOUR
CFM CUBIC FEET PER MINUTE
CFT CUBIC FEET
CR CEILING REGISTER
CAV CONSTANT AIR VOLUME
GA GAUGE
GPM GALLONS PER MINUTE
GS GALVANIZED STEEL
HAC HOUSEKEEPING AID CLOSET
HB HOSE BIBB
HD HEAD
HP HORSEPOWER
HSTAT HUMIDISTAT
HZ HERTZ
I/O INPUT/OUTPUT
IAQ INDOOR AIR QUALITY
ID INSIDE DIAMETER
IN. INCHES
IN. WG INCHES WATER GAUGE
IS INSECT SCREEN
OA OUTSIDE AIR
OD OUTSIDE DIAMETER
PD PRESSURE DROP
PG PRESSURE GAGE
PPM PARTS PER MILLION
PSI POUNDS PER SQUARE INCH - ABSOLUTE
PSIA POUNDS PER SQUARE INCH - GAGE
PSIG POUNDS PER SQUARE INCH - GAGE
RA RETURN AIR
RAT RETURN AIR TEMPERATURE
RF RETURN FAN
RH RELATIVE HUMIDITY
RR RETURN REGISTER
SA SUPPLY AIR
SAT SUPPLY AIR TEMPERATURE
SD SUPPLY DIFFUSER
SDPR SMOKE DAMPER
SF SUPPLY FAN
SI SQUARE INCHES
SP STATIC PRESSURE
SPS STATIC PRESSURE SENSOR
SQF SQUARE FOOT (FEET)
D DAMPER - AUTOMATIC
DB DECIBELS
Db DRY-BULB TEMPERATURE
DDC DIRECT DIGITAL CONTROLS
DEG DEGREE
DIF DIFFUSER
DIA DIAMETER
DPS DIFFERENTIAL PRESSURE SENSOR
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
ECC ENGINEERING CONTROL CENTER
EF EXHAUST FAN
ER EXHAUST REGISTER
(E) EXISTING
F FAHRENHEIT
F/S DPR COMBINATION FIRE SMOKE DAMPER
FA FREE AREA
FC FLEXIBLE CONNECTION
FD FIRE DAMPER
FPM FEET PER MINUTE
FPS FEET PER SECOND
FS FLOW SWITCH
FT FEET
KW KILOWATT
KWH KILOWATT HOUR
LAT LEAVING AIR TEMPERATURE
LB/HR POUNDS PER HOUR
LF LINEAR FOOT (FEET)
LPR LOW PRESSURE RETURN (STEAM
CONDENSATE)
LPS LOW PRESSURE STEAM
LVR LOUVER
MA MIXED AIR
MAT MIXED AIR TEMPERATURE
MAX MAXIMUM
MB MIXING BOX
MBH 1000 BTUH
MER MECHANICAL EQUIPMENT ROOM
MERV MINIMUM EFFICIENCY REPORTING VALUE
MHP MOTOR HORSEPOWER
MIN MINIMUM
NA NOT APPLICABLE
NC NOISE CRITERIA
N.C. NORMALLY CLOSED
N.O. NORMALLY OPEN
NTS NOT TO SCALE
TAB TESTING, ADJUSTING, BALANCING
TD TEMPERATURE DIFFERENCE
TSP TOTAL STATIC PRESSURE
TSTAT THERMOSTAT
TYP. TYPICAL
VAV VARIABLE AIR VOLUME
VD VOLUME DAMPER (MANUAL OPPOSED BLADE)
Wb WET-BULB (TEMPERATURE)
W/ WITH
WMS WIRE MESH SCREEN
REMOVE EXISTING EQUIPMENT, AIR TERMINALS
WALL MOUNTED THERMOSTAT
DUCT MOUNTED TEMPERATURE SENSOR
F/S DPR
AIR FLOW DIRECTION (POSITIVE PRESSURE)
AIR FLOW DIRECTION (NEGATIVE PRESSURE)
UNDERCUT (ON DOOR)
(WALL TYPE)
SUPPLY TOP REGISTER OR GRILLE (WALL TYPE)
EXHAUST OR RETURN TOP REGISTER OR GRILLE
2 TYP.
1 TYP.
3 TYP.
2 TYP.
1 TYP.
1 TYP.
1 TYP.
1 TYP.
3 TYP.
3 TYP.
2 TYP.
1 TYP.
1 TYP.
CONVECTOR TO REMAIN (TYP)
CONVECTOR TO REMAIN (TYP)CONVECTOR TO REMAIN (TYP)
CONVECTOR TO REMAIN (TYP)CONVECTOR TO REMAIN (TYP)CONVECTOR TO REMAIN (TYP)CONVECTOR TO REMAIN (TYP)
CONVECTOR TO REMAIN (TYP)
CONVECTOR TO REMAIN (TYP)
CONVECTOR TO REMAIN (TYP)
REMOVE CEILING MOUNTED SUPPLY DIFFUSER. TYPICAL FOR ALL DIFFUSERS.
REMOVE CEILING MOUNTED RETURN OR EXHAUST REGISTER. TYPICAL FOR ALL REGISTERS.
REMOVE WALL MOUNTED THERMOSTAT. TYPICAL FOR ALL THERMOSTATS.
DEMOLITION KEY NOTES:
1 1. DEMOLITION OF THERMOSTATS SHALL INCLUDE REMOVAL OF CONTROL WIRING
AND/ OR PNEUMATIC PIPING.
2. SEE DRAWING 100-MD102 FOR DUCTWORK AND MIXING BOXES DEMOLITION.
NOTES:
19"Ø COLD
17"Ø HOT
19"Ø COLD
17"Ø HOT
20x14 EXH
34x20 RET
1 1TYP.
TYP.
1 TYP. 1 TYP.
1 TYP.
1 TYP.
1 TYP.
1 TYP.
1 TYP.
1 TYP.
24"Ø COLD DECK DUCT
TO REMAIN
21"Ø HOT DECK DUCT
TO REMAIN
1 TYP.
1 TYP.
16x12 EXHAUST DUCT
TO REMAIN
EF-31
AH-27
RF-21
x2
R
E T
34x20 RET
28x28 RETURN
DUCT TO REMAIN
2 TYP.
3 TYP.
3 TYP. 3 TYP.
4 TYP.
4 TYP.
5 TYP. 5 TYP.
2 TYP.
3TYP.
4 TYP.
MIXING BOX MB 5-A
(501) TO REMAIN
2 TYP.
17"Ø COLD
15"Ø HOT
12x6 12x6
20x7
20x12 EXH
12x6
12x6 7"Ø
28x16
18x14 16x12 16x10
1 TYP.
1 TYP.
10"Ø
12"Ø
12"Ø
15"Ø
10"Ø12"Ø
12"Ø
15"Ø17"Ø COLD
15"Ø HOT
9"Ø 11"Ø
10"Ø 15"Ø
11"Ø
10"Ø 12"Ø 12"Ø
12"Ø
12"Ø
12"Ø
13"Ø
13"Ø
15"Ø
14x10 10x6 6x6
18x10 14x10 12x10 12x6 6x6
14x10
20x1228x16
16x8
14x8
14x8 12x8
14x6
28x24
38x14 x1 x1 x1 x6
12x6
17"Ø COLD
15"Ø HOT
MIXING BOX MB 4-B
(533) TO REMAIN
FD
FD
REMOVE MIXING BOX MB 4-B (533),
DISCONNECT CONTROL PIPING
FROM THERMOSTAT
REMOVE DUAL DUCT MIXING BOX WITH ALL ASSOCIATED DUCTWORK, CONTROLS, ETC.
REMOVE PNEUMATIC CONTROL PIPING BACK TO MAIN AND CAP. TYPICAL FOR ALL MIXING
BOXES.
REMOVE SUPPLY DUCTWORK WITH ALL ASSOCIATED ACCESSORIES, SUPPORTS UP TO THE
POINTS OF DISCONNECTION AS SHOWN.
REMOVE EXHAUST DUCTWORK WITH ALL ASSOCIATED ACCESSORIES, SUPPORTS UP TO
THE POINTS OF DISCONNECTION AS SHOWN.
REMOVE RETURN DUCTWORK WITH ALL ASSOCIATED ACCESSORIES, SUPPORTS UP TO
THE POINTS OF DISCONNECTION AS SHOWN.
REMOVE WALL MOUNTED THERMOSTATS. DISCONNECT AND REMOVE CONTROL PIPING.
TYPICAL FOR ALL THERMOSTATS.
DISCONNECT CONTROL PIPING TO THE MIXING BOX TO BE REMOVED, KEEP THERMOSTAT
AND CONTROL PIPING TO THE REMAINING MIXING BOX.
DEMOLITION KEY NOTES:
NOTES:
1. PRIOR TO DEMOLITION TEST THE EXISTING AIR DISTRIBUTION, RETURN AND EXHAUST SYSTEMS.
OBTAIN READING OF AIR FLOWS AND STATIC PRESSURES AT DUCT MAINS SERVICING THE SPACE.
SUBMIT TESTING REPORT TO COTR.
2. SEE DRAWING 100-MD101 FOR DEMOLITION OF CEILING MOUNTED DIFFUSERS AND REGISTERS AND
WALL MOUNTED THERMOSTATS.
FDFD
FD
FD
SD-7
(240)
RR-8
(480)
SD-5
(130)
SD-10
(115)
SD-7
(300)
SD-5
(70)
SD-7
(250) SD-5
(50)
SD-9
(30)
SD-3
(310)
SD-9
(100)
SD-9
(80)
SD-10
(150)
SD-9
(100)
SD-6
(140)
SD-5
(80)
RR-8
(540)
SD-6
(190)
SD-5
(90)
SD-5
(80)
SD-5
(90)
SD-5
(100)
RR-5
(130)
RR-7
(340)
SD-13
(170)
SD-2
(270)
SD-2
(270)
SD-10
(180)
SD-2
(205)
ER-2
(95)
RR-3
(315)
RR-18
(130)
RR-18
(130)
SD-13
(130)
SD-1
(110)
SD-1
(120)
RR-1
(110)
SD-2
(250)
SD-6
(180)
SD-12
(60)
SD-6
(150)
SD-1
(140)
RR-4
(80)
SD-3
(320)
SD-9
(80)
SD-9
(80)
ER-2
(95)
SD-13
(220)
SD-14
(260)
SD-14
(280)
SD-3
(330)
SD-14
(270)
SD-14
(270)
SD-9
(100)
SD-11
(230)
ER-4
(100)
ER-3
(40)
ER-4
(85)
RR-4
(100)
RR-5
(150)
ER-4
(120)
RR-18
(80)
RR-19
(180)
RR-20
(360)
RR-1
(175)
RR-22
(810) ER-3
(60)
RR-5
(150)
RR-1
(175)
RR-3
(275)
RR-3
(275)
SD-9
(30)
ER-3
(75)
ER-4
(100)
RR-1
(120)
ER-4
(100)
RR-4
(110)
RR-5
(150)
RR-8
(520)
RR-13
(210)
RR-16
(580)
RR-21
(440)
RR-14
(280)
SD-5
(130)
RR-4
(100)
RR-4
(90)
ER-3
(75)
ER-2
(95)
ER-3
(75)
ER-4
(160)
RR-8
(450)
(E) CONVECTOR (TYP)
ER-3
(75)
ER-3
(75)
(E) CONVECTOR (TYP)(E) CONVECTOR (TYP) (E) CONVECTOR (TYP)
(E) CONVECTOR (TYP)(E) CONVECTOR (TYP)
SD-2
(270)
SD-2
(270)
(E) CONVECTOR (TYP)
SD-3
(370)
SD-2
(270)
SD-2
(270)
SD-2
(270)
SD-2
(270)
SD-3
(370)
SD-3
(370)
SD-3
(370)
SD-2
(240)
SD-2
(240)
SD-2
(240)
SD-2
(270)
SD-2
(240)
SD-2
(270)
SD-2
(270)
SD-2
(270)
SD-2
(270)
SD-2
(205)
SD-3
(380)
SD-3
(380)
SD-2
(280)
SD-3
(300)
SD-2
(280) SD-2
(280)
RR-1
(140)
SD-2
(200)
SD-3
(320)
RR-16
(600)
SD-2
(230)
SD-2
(240) RR-14
(400)
SD-7
(300)
SD-6
(140)
SD-6
(170)
SD-6
(170)
SD-13
(180)
SD-13
(180)
SD-13
(180)
SD-13
(130)
SD-6
(180)
SD-5
(110)
SD-13
(220)
SD-14
(260)
RR-22
(800)
SD-5
(100)
SD-5
(100)
SD-6
(190)
SD-9
(80)
SD-9
(80)
SD-7
(240)
ER-3
(75)
ER-2
(95)
ER-2
(95)
ER-2
(95)
ER-2
(95)
ER-2
(95)
ER-2
(95)
ER-2
(95)
ER-2
(95)
ER-2
(95)
ER-2
(95)
ER-2
(95) ER-2
(95)
ER-2
(95)
ER-2
(95)
ER-2
(95)ER-2
(95)
ER-2
(95)ER-2
(95)
ER-2
(95) RR-1
(175)
RR-1
(175) RR-1
(175)
RR-1
(175) RR-1
(175)
RR-1
(175)
RR-1
(175)
RR-1
(175)
RR-1
(175)RR-1
(175)
RR-1
(175)
RR-1
(175)
RR-1
(145)
RR-1
(145)
RR-1
(145)
RR-1
(145)
RR-3
(275)
RR-3
(275)
RR-16
(600)
RR-4
(100)
RR-4
(100)
SD-5
(50)
RR-4
(90)
SD-13
(150)
SD-13
(150)
SD-13
(170)
RR-22
(720)
RR-7
(300)RR-1
(145)
RR-15
(500)
SD-2
(270)
RR-16
(740)
RR-13
(240)
ER-2
(95)
SD-2
(240)
SD-14
(270)
SD-2
(290)
(E) CONVECTOR (TYP)
(E) CONVECTOR (TYP)
24x24
TRANSFER
GRILLE
RR-4
(80)
SD-12
(90)
SD-3
(380)
SD-3
(380)
ER-2
(95)
SD-9
(30)SD-9
(30)
SD-9
(30)
NOTES:
1. SEE DRAWING 100-MH102 FOR LOCATIONS OF DUCTWORK, DUCT MOUNTED
ACCESSORIES, MIXING BOXES, ETC.
24"Ø COLD
24"Ø
"Ø
H O
T
20x14 EXH
34x20 RET
(E) 24"Ø COLD DECK
DUCT
(E) 21"Ø HOT
DECK DUCT
(E) 16x12
EXHAUST DUCT
(E) EF-31
(E) AH-27
(E) RF-21
34x20 RET
(E) 28x28
RETURN DUCT
20x12 EXH
(E) 24x20
MB-6-A-9
MB-6-A-1
MB-6-A-3
MB-6-A-4
MB-6-A-2
MB-6-A-5
MB-6-A-6
MB-6-A-7
MB-6-A-8
MB-6-A-12MB-6-A-13
MB-6-A-14
MB-6-A-15
MB-6-A-10
MB-6-A-11
MB-6-C-1
MB-6-C-2
MB-6-C-3
MB-6-C-4
MB-6-C-5
MB-6-C-6
MB-6-C-7
MB-6-C-8
MB-6-C-38
MB-6-C-9
MB-6-C-33
MB-6-C-30
MB-6-C-10
MB-6-C-11MB-6-C-12
MB-6-C-13
MB-6-C-14
MB-6-C-15
MB-6-C-16
MB-6-C-24
MB-6-C-25
MB-6-C-17
MB-6-C-26
MB-6-C-22
MB-6-C-21
MB-6-C-18
MB-6-C-34
MB-6-C-35
MB-6-C-37
MB-6-C-23
MB-6-C-19
MB-6-C-20
MB-6-C-28
MB-6-C-39
(E)16x8
12x8 x1
16x6
8"Ø 6"Ø
14x6
6"Ø
14x6
16x6
16x616x6
10"Ø
14x6
16"Ø
(E)15"Ø COLD
4"Ø
12x8 x1
(E) 24"Ø COLD
DECK DUCT
18"Ø
13"Ø11"Ø
8"Ø
6"Ø
6"Ø
12x8
8x8
8x6
14x6
12"Ø10"Ø
14"Ø
10x6
6"Ø x8 x8
10x4 x414 x4 x8
8x8
8x8
14x6
16x8
8x6
14x8 10x8
12x8
14x8
18x12
14x8 x1
12x8
8x6 x8 x6
12x8 x1
12"Ø
11"Ø
MB-6-C-36
16x616x10 12x10
"Ø
C O
LD
17"Ø
24"Ø 22"Ø 20"Ø 19"Ø
12"Ø
15"Ø18"Ø
14"Ø
16x12
15"Ø20"Ø22"Ø 18"Ø
13"Ø 12"Ø14"Ø16"Ø18"Ø20"Ø 20"Ø 12x6
22"Ø22"Ø
10x6
14x8
10x6
8x4
14x8 (E)14x8
8x4 8x4
16x10
10x8
10x6
14x814x10
14x1016x12
10x4
10x610x8
10x4
10x6
(E) 17"Ø COLD
DECK DUCT
(E) 15"Ø HOT
DECK DUCT
x8
16"Ø
13"Ø
14x8
16x8 18x8
8x4
28x16 x1 x1
28x18
28x20
15"Ø
13"Ø 12"Ø10"Ø
10"Ø
20x10
8x6
8x6 x8 x8
12x6 x4 x4
10x4 x1
12x8
10x6
10x6 x4 x414 x4 x4
14x616x1216x1418x1424x14
10x6
24x18
22"Ø
26x20 x6
30x20 x6
14x10
16x6
12x8 x8 x8
10x4
10x8
14x12 x6
16x1018x10
16x8 x6
18x12
22x16
12x4 16x6
14x8 x6 x6
26x18
14x6
26x20
MB-6-C-29
18x8
12x4 x6
28x20
8x6
10x6 14x8 x8
8x4
8x6
6x6 14x8
12x6
10x610x8
8x6 10x4
12x8
6x6
6x6
10x8
10x6
16x10
14x6
10x4
10x4
10x4
12x610x6
10x4
18x10
14x8
16x8 14x8
12x6
10x4
10x6
8x4
16x818x8
10x6 10x4 10x6
10x4
8x4
6"Ø 6"Ø
8"Ø
8"Ø
10"Ø
8x4
14x8
14x6 14x6
8x4
10x48"Ø8"Ø
16x8 6x6
10x8
(E) MB
5-A
(501)
10x6
6x6
6x6
10x4
14x10
14x10
10x10
8x8
10x6
10x4
14x6
MB-6-C-32
16x6
16x6
16x6
16x8
12x8
8x4 10x4
MB-6-A-16
22x6 DUCT
OPENING
W /WMS (530)
36x6 DUCT
OPENING
W /WMS (530)
MB-6-C-42
12x6 DUCT
OPENING
W /WMS (265)
MB-6-C-43
6x6 DUCT
OPENING
W /WMS (100)
MB-6-C-40
12x6 DUCT
OPENING
W /WMS (265)
MB-6-C-41
6x6 DUCT
OPENING
W /WMS (100)
12x8
TO MB-6-A-16
MIXING BOX MB 4-B
(533) TO REMAIN
TO MB-6-C-41
18x12 DUCT
OPENING
W /WMS (530)
14x6 DUCT
OPENING
W /WMS (200)
14x6 DUCT
OPENING
W /WMS (200)
10x8
10x4
16x10 ASVD N.C. (1972)
MB-6-C-27
12x6
12"Ø
16x8
16x12
16x6
16x6
16x10
8x8
15x12 ASVD N.C. (1968)
8x8
4" Ø ALUMINUM DRYER EXHAUST,
TERMINATE 10'-0" ABOVE GROUND
WITH APPROVED VENT HOOD
WHICH HAS A SWING-OUT DAMPER
14x8
14x614x10
12x6
14x6
14x6
12x4
16x8 10x8
10x8
16x10
14x6
14x4
16x10 x1
8x8
16x8
NOTES:
1. RUN SUPPLY COLD DUCTS, SUPPLY HOT DUCTS, MAIN RETURN DUCT, AND MAIN
EXHAUST DUCT THROUGH TRUSSES.
2. INSTALL MIXING BOXES SHALL AT ELEVATION OF BOTTOM OF TRUSS. LOCATE BOXES
TO ALLOW ACCESS THROUGH CEILING FREE OF TRUSS SUPPORT ANGLES.
3. RUN LOW VELOCITY SUPPLY DUCTWORK (DISCHARGE FROM BOXES), RETURN AND
EXHAUST BRANCH DUCTWORK AS CLOSE TO BOTTOM TRUSS CHORD AS POSSIBLE
WHEN CROSSING TRUSSES.
4. COORDINATE INSTALLATION OF DUCTWORK WITH PLUMBING AND ELECTRICAL
CONTRACTORS.
5. SEE DRAWING 100-MH101 FOR LOCATIONS OF CEILING MOUNTED DIFFUSERS AND
REGISTERS AND WALL MOUNTED THERMOSTATS.
8"Ø
8"Ø
10"Ø
6"Ø
14x4
8"Ø
8"Ø
6"Ø
8"Ø
6"Ø
4"Ø
6"Ø
12"Ø
10"Ø
4"Ø
8x6
10"Ø12"Ø12"Ø22"Ø
8x8
8x6
8x4
16x10
8x4
12x6
12x6
12x612x6
10x6
10x4
12x6
6"Ø
6"Ø
6"Ø 8"Ø
18x10
8x4
8x48x6
8x4
13"Ø
8"Ø
8"Ø
6"Ø 6"Ø
10"Ø 10"Ø
6"Ø
6"Ø 8"Ø
10x4
10x4
10x4
10x4
4"Ø
12x6 12x6
12x6
14x6
10x8
8x4
14x4
6"Ø
6"Ø
14x4
6"Ø
6x6
6"Ø x4
14x6
8x6
24x14
10x4
6x6
10x6
8x6 x4
12"Ø
22"Ø HOT
FDFD
FD
FD
10x4
12x6
12x6
8x4
13"Ø x1
14x4 10x8
8x6
14x8
16x6
FD
FD
(E) 50x24
NTS
NOTE:
1.
2.
3.
4.
ALL VANE ELBOWS SHALL BE CONSTRUCTED AND INSTALLED AS DETAILED BY SMACNA.
WHEN W1 DOES NOT EQUAL W2, VANE SHALL BE SINGLE THICKNESS VANE TYPE
REGARDLESS OF W DIMENSION.
ALL SINGLE THICKNESS VANES SHALL HAVE A 2" RADIUS, 1 1/2" MAXIMUM SPACE BETWEEN
VANES AND A 3/4" TRAILING EDGE.
WHEN W EQUALS W2 AND W1 IS GREATER THAN 20" [500mm] VANES SHALL BE DOUBLE VANE
TYPE.
W
W1
NTS
VANE
VANE
NOTE:
1.
2.
THE INTERIOR SURFACE OF ALL RADIUS ELBOWS SHALL BE MADE ROUND.
ALL STANDARD RADIUS ELBOWS CAN BE SUBSTITUTED WITH SHORT RADIUS ELBOWS. ALL
SHORT RADIUS ELBOWS SHALL HAVE VANES. VANES SHALL BE CONSTRUCTED, SUPPORTED
AND FASTENED AS RECOMMENDED BY SMACNA.
R SHALL
EQUAL OR
BE
GREATER
THAN W.
R SHALL
EQUAL OR
BE
GREATER
THAN 1/3W.
W
R
R
2/3W 1/ 3W
R SHALL
EQUAL OR
BE
GREATER
THAN 1/6W.
STANDARD RADIUS OR LONG
RADIUS ELBOW
SHORT RADIUS ELBOW
WITH ONE VANE
SHORT RADIUS ELBOW
WITH TWO VANES
W W
1/2W 1/ 3W
1/6W
R
NTS
AIR SPLIT DUCT TAKE-OFF PLAN VIEW
BRANCH DUCT TAKE-OFF PLAN VIEW
SUPPLY REGISTER TAKE-OFF
PLAN VIEW
AIR
FLOW
AIR
FLOW
A
IR
FL
O
W
SUPPLY REGISTER
OR BRANCH DUCT
TURNING VANES
MAIN
SUPPLY
DUCT
SEE FLOOR PLAN FOR
SPLIT DIMENSION
PROVIDE VOLUME
DAMPER
PROVIDE VOLUME
DAMPER
ADJUSTABLE
METAL ROD
OR LINKAGE
TOP REGISTER
MAIN
SUPPLY
DUCT
VOLUME EXTRACTOR;
ADJUSTABLE FROM FULLY
CLOSED POSITION TO CFM
NOTED ON FLOOR PLANS
AIR
FLOW
AIR
FLOW
1/4 W OR 4"
MIN.
AIR
FLOW
MAIN SUPPLY
DUCT
W
A
IR
FL
O
W
NTS
RIGID DUCT TO AIR TERMINAL
UNIT.
ROUND SHEET METAL DUCT.
MAIN SUPPLY
"D"
45°M
AX.
PLAN VIEW
NTS
SMACNA FIGURE 4-6
45° LEED IN
RIGID DUCT TO AIR TERMINAL
UNIT.
MAIN SUPPLY
PLAN VIEW
FLOW
FL
O
W
NTS
MAIN EXHAUST OR RETURN
PLAN VIEW
AIR
FLOW AIR
FLOW
W
PROVIDE VOLUME DAMPER
AT EACH BRANCH DUCT
1/4W OR 4" MIN.
BRANCH DUCT
VD
NTS
NOTE:
1.
2.
DELETE INSULATION STAND-OFF ON DUCTWORK WITHOUT EXTERIOR INSULATION.
DETAIL SHOWS SINGLE BLADE DAMPER. DAMPER INSTALLATION SHALL BE SIMILAR FOR
MULTI-BLADE DAMPERS & ROUND DAMPERS.
INSULATION SEE
SPECIFICATION
DAMPER BLADE
1/8"
CLEARANCE
ALL AROUND
OUTSIDE END BEARING
INSIDE END BEARING
HANDLE WITH
LOCKING
QUADRANT
INSULATION
STAND-OFF
1/2" ROUND ROD PIN
DUCT
STIFFEN BLADE
AS REQUIRED
SIDE ELEVATION SECTION
SECTION "A-A"
"B" "B"
NTS
NOTES:
1. LATCHES SHALL BE OF THE WEDGE TYPE TO CLOSE DOORS TIGHTLY.
2. HINGES ON THE ACCESS DOORS SHALL HAVE NON-CORROSIVE PINS.
3. SEE SMACNA 2005, FIGURE 9-15
ACCESS PANEL
ACCESS DOOR
CASING
GASKET
HANDLE INSIDE
FLEXIBLE
WASHER
FACTORY
FABRICATED
LATCH
SECTION "B-B"
INSULATION
DUCT
GASKET
INSULATION
INSULATION
"A"
"A"
NTS
HOUSING WELDED
TO DUCT SECTION
ROUND OR
FLAT OVAL
DUCT SECTION
COVER WITH HANDLE
AND CHAIN RETAINER
GASKETED AND
PRESSURE SEALED
NTS
ROUND FLEXIBLE CONNECTION
RECTANGULAR FLEXIBLE CONNECTION
FLANGED CONNECTION
ON FAN SIDE
WASHER 1-1/2" MIN. TO 3" MAX. INSTALLED.
6" NOMINAL WITH MATERIAL TAUT
FLEXIBLE
MATERIAL AS
SPECIFIED
1"x1/8" DRAW BAND
1"x1/8" BAND IRON
BOLT ON 4" CENTERS
5/16" FLANGE
DUCT
SHEET METAL SCREWS ON
12" CENTERS
RIVET ON 4"
CENTERS
SHEET METAL AS
SPECIFIED FOR
DUCTWORK.
1"x1/8" BAND IRON
BOLT ON 4" CENTERS
1" FLANGE & HEMALTERNATE
POSITION
OF BOLT 1 1/2" POCKET SLIP
DUCT
SHEET METAL AS
SPECIFIED FOR
DUCTWORK.
1/2" 1/2" 1 1/2"
1 1/2" MIN. TO 3" MAX. INSTALLED. 6"
NOMINAL WITH MATERIAL TAUTFLANGED
CONNECTION ON
FAN SIDE
WASHER
FLEXIBLE MATERIAL
AS SPECIFIED
NTS
NOTES:
1. RIGID STRAIGHT TERMINAL UNIT INLET LENGTH SHALL BE A MINIMUM OF 3 TIMES THE DIAMETER
OF INLET
2. A FLEXIBLE AIR DUCT CONNECTOR IS NOT MANDATORY FOR INLET TO THIS BOX, BUT ALLOWED
TO ACCOMMODATE MINOR OFFSETS. MAXIMUM LENGTH 3'-0".
3. A BRANCH DUCT SERVING AN INDIVIDUAL BOX MAY BE THE SAME SIZE AS THE BOX INLET, PROVIDED THE EQUIVALENT LENGTH OF THE BRANCH DUCT, AS SHOWN, DOES NOT EXCEED 10
FEET. FOR LONGER LENGTHS, INCREASE THE DUCT SIZE AND PROVIDE A DUCT TRANSITION TO
MAINTAIN THE DUCT STATIC PRESSURE DROP AT OR BELOW 0.2"/100'.
4. FLEXIBLE AIR DUCT CONNECTORS, WHEN USED FROM TERMINAL UNIT SUPPLY AIR DUCT TO
DIFFUSER, SHALL NOT EXCEED 5'-0". USE RIGID ELBOWS FOR CHANGE OF DIRECTION GREATER
THAN 45°.
5. COMPONENT ARRANGEMENT MAY VARY BY MANUFACTURER. PROVIDE INSULATION W/VAPOR
BARRIER FOR CONNECTING DUCT SECTIONS.
AIR TERMINAL UNIT
DIFFUSER (TYP.)
SEE SPECIFICATIONS FOR
CLAMPS AND SEALANT (TYP.)
SEE NOTE 5
SEE NOTE 3
SEE NOTE 2
SEE NOTE 1
H O
T D
E C
K S
U P
P
LY
D U
C T
C O
LD
D
E C
K S
U P
P
LY
D U
C T
SUPPLY DUCT
CONTROL GRID
CEILING
CONTROL GRIDCEILING
SUPPLY DUCT
SIDE VIEW
CEILING DIFFUSERS
ROUND AND/OR SQUARE NECK CEILING DIFFUSER TAKE-OFFS
SIDE VIEW
VOLUME DAMPER
CEILING
DUCT
ROUGH OPENING
PANEL/FRAME
DUCT COLLAR
TAMPER PROOF SCREWS
MULTI-BLADE DAMPER FOR
ROUND NECK DIFFUSER &
OPPOSED BLADE DAMPER FOR
SQUARE NECK DIFFUSER
APPROVED INSERT
1" X 1" X 1/8" 1" X 1" X 1/8" 1 1/2"X1 1/2"X1/8"
2" X 2" X 3/16"
2" X 2" X 1/4"
1 1/2"X1 1/2"X1/8" 2" X 2" X 1/8"
LONGEST
UP TO 18"
31" TO 42"
43" TO 60"
61" TO 84"
19" TO 30"
85" TO 96"
97" & OVER
DIMENSION
OF DUCT
NOTES:
4' - 0"3/8" ROD
4' - 0"3/8" ROD
8' - 0"
6' - 0" 6' - 0"
4' - 0" 4' - 0"
SPACING
NOTE #4
MAXIMUM
8 GA. WIRE
1/4" ROD
1/4" ROD
3/8" ROD
3/8" ROD
HANGERS
ROUND
1" X 1/8" 1" X 1/8" 1" X 1/8"
HANGERS
STRAP
AND HANGER
UNDERSIDE OF BEAM
TRAP
SHELF
HANGERS
TO EXISTING AIR
HANDLING UNIT
FROM EXISTING AIR
HANDLING UNIT
HOT DECK SUPPLY DUCT
COLD DECK SUPPLY DUCT
RETURN DUCT
FROM ROOM6TH FLOOR
INTERSTITIAL SPACE
SUPPLY DUCT
TO ROOM
SUPPLY DUCT
TO ROOM
SUPPLY DUCT
TO ROOM
ROOM SERVED
BY MIXING BOX
ROOM SERVED
BY MIXING BOX
ROOM SERVED
BY MIXING BOX
RETURN DUCT
RETURN DUCT
FROM ROOM
RETURN DUCT
FROM ROOM
TT
T
NTS
NTS
1. ALL DUCTWORK TO BE HUNG FROM BUILDING CONSTRUCTION NOT TO BE SUPPORTED FROM HUNG CEILING.
2. WHEN DUCT AREA EXCEEDS 8 SQ. FT. ANGLE STIFFENERS REQUIRED AROUND CIRCUMFERENCE OVER 4' - 0"
3. FOR DUCTS OVER 48" WIDE, HANGERS SHALL TURN UNDER DUCT AT LEAST 2" AND SHALL BE FASTENED TO THE
BOTTOM AS WELL AS TO THE SIDES OF DUCT.
4. FOR DUCTS WITH CROSS-SECTIONAL AREA OF 4 SQ. FT. OR LESS, HANGERS SHALL BE MORE THAN 8 FT APART; FOR
DUCTS WITH CROSS-SECTIONAL AREA OF MORE THAN 4 SQ. FT. BUT NOT OVER 8 SQ. FT., HANGERS SHALL BE NO MORE THAN 6 FT. APART; FOR DUCTS WITH A CROSS-SECTIONAL AREA OF MORE THAN 8 SQ. FT., HANGERS SHALL NOT BE MORE THAN 4 FT. APART. THE DISTANCES SHALL BE MEASURED LINEARLY ALONG THE DUCT.
5. VERTICAL DUCTS SHALL BE SECURELY SUPPORTED AT EACH FLOOR LEVEL BY CONTINUOUS LENGTHS OF STRUCTURAL ANGLES OF A SIZE AT LEAST EQUIVALENT TO THAT FOR STIFFENING. THE ANGLES SHALL BE FASTENED TO THE OPPOSITE SIDES OF THE DUCT AND SHALL EXTEND ACROSS THE OPENING AND BEAR UPON THE
STRUCTURE OR SLAB ON BOTH SIDES OF THE OPENING.
NTS
420ONE 1 x 18 GA STRAP36
TWO 1/2Ø RODS
TWO 3/8Ø. RODS
ONE 1 x 16 GA STRAP
50 700
ONE 1 x 22 GA STRAP
QUANTITY/SIZEMAX. DUCT Ø
MAX. LOAD
LBS.
MAX.
IN.
SPACING
IN. IN.
NOTE:
TABULATED DATA FROM SMACNA ALLOWS FOR DUCT
REINFORCING AND INSULATION, BUT NO EXTERNAL LOAD.
BAND
OVER 50"Ø
HANGER RODS
BAND OF SAME
SIZE AS HANGER
STRAP
LOAD RATED
FASTENERS
50"Ø & UNDER
DUCT HANGERS
NOT LESS THAN
1" x 1/8"
MIXING BOXES AND THEIR CONTROLLERS SHALL BE FULLY COMPATIBLE WITH AND INTEGRATED
INTO EXISTING BUILDING MANAGEMENT SYSTEM (BMS) BY JOHNSON CONTROLS.
1. FOR MIXING BOXES SERVICING ROOMS IN AREA "A" AND CONNECTED TO UNIT AHU-34:
IN COOLING MODE, AS TEMPERATURE APPROACHES SET POINT 75°F (ADJUSTABLE), COLD AIR
MODULATES FROM MAXIMUM TO A MINIMUM MIX FLOW RATE. AS TEMPERATURE CONTINUE TO
DROP, HOT AIRFLOW MODULATES OPEN AS COLD AIRFLOW CLOSES, MAINTAINING SPACE
TEMPERATURE AT THE PROPER SET POINT: 75°F COOLING (ADJUSTABLE), 70°F HEATING
(ADJUSTABLE).
2. FOR MIXING BOXES SERVICING ROOMS IN AREA "C" AND CONNECTED TO UNIT AHU-27:
IN THIS SEQUENCE COOLING AND HEATING MINIMUM FLOW RATES ARE THE SAME AND MINIMUM
MIX FLOW RATES ARE THE SAME AS MAXIMUMS. THE RESULT IS A CONSTANT AIRFLOW OVER
THE ENTIRE COOLING AND HEATING RANGE. ON A CHANGE IN SPACE TEMPERATURE FROM ITS
SET POINT, THE TEMPERATURE SENSOR LOCATED EITHER IN THE ROOM OR IN THE RETURN AIR
DUCT SHALL MODULATE THE MIXING BOX DAMPERS TO MAINTAIN SPACE TEMPERATURE AT THE
PROPER SET POINT : 75°F COOLING (ADJUSTABLE), 70°F HEATING (ADJUSTABLE).
3. FOR MIXING BOXES SERVICING INTERSTITIAL SPACE:
WHEN THE TEMPERATURE IN INTERSTITIAL SPACE IS ABOVE 60°F, THE MIXING BOX SHALL BE
CLOSED. WHEN THE SPACE TEMPERATURE DROPS TO 60°F THE MIXING BOX SHALL MODULATE
TO MAINTAIN INTERSTITIAL SPACE TEMPERATURE AT SET POINT (ADJUSTABLE).
NOTES:
1. A VERTICAL DAMPER IS SHOWN. HORIZONTAL DAMPER INSTALLATION, IS SIMILAR. FOLLOW
DAMPER MANUFACTURER'S INSTRUCTIONS, INCLUDING FASTENER OPTIONS AND GAGES FOR
SLEEVE AND PERIMETER ANGLES. FIRE DAMPERS MUST BE INSTALLED IN THE PARTITION OR
FLOOR AND NOT OUTSIDE THE PENETRATION.
2. GALVANIZED SLEEVE: GAGE NOT LESS THAN CONNECTING DUCT. FASTEN SLEEVE TO
DAMPER FRAME AND TO PERIMETER ANGLES.
3. PERIMETER ANGLES: GALVANIZED STEEL, NOT LESS THAN 1-1/2"x1-1/2"x14 GAGE, TO PROVIDE
1" MINIMUM OVERLAP OF OPENING ON ALL 4 SIDES.
4. BREAKAWAY DUCT CONNECTION: CONTRACTOR'S OPTION OF TYPES SHOWN IN SMACNA.
5. ACCESS PANELS: SIZE AND LOCATION TO PERMIT SERVICING THE FUSIBLE LINK OR LINKS.
6. PROVIDE 1/4" TO 1/2" CLEARANCE ON HEIGHT AND WIDTH. FILL OPEN SPACE WITH ROCK
WOOL FIRE STOP FIBER.
SLEEVE, NOTE 2
DUCT
CONNECTION
NOTE 4
DAMPER, NOTE 1
DAMPER COLLAR
EXTENSION INTEGRAL
PART OF SLEEVE
SLEEVE, NOTE 2
NOTE 6
FIRE BARRIER
PARTITION OR CHASE
TYPICAL DUCT
INSULATION
PERIMETER ANGLE, NOTE 3
(NOTE FASTENED TO PARTITION)
ACCESS
PANEL,
NOTE 5
6" MAX
TITUS AS STANDARD
TAG AHU TAG AREA SERVED QUANTITY MODEL CONTROL
TYPE
INLET SIZE
OUTLET
SIZE
IN.
UNIT MAX
ALLOWABLE
AIR FLOW
CFM
UNIT MIN
ALLOWABLE
AIR FLOW
CFM
AIR FLOW STATIC PRESSURE NC LEVELS
COLD
DIA
IN.
HOT
DIA
IN.
MAX
CFM
MIN
CFM
INLET
IN.
WG
DOWN
IN.
WG
MIN
IN.
WG
RAD. DISH.
MB-6-C-1 AHU-27 AREA C 1 DMDV VAV 10 10 10x11 1400 145 880 230 1 0.25 0.2 23 17
MB-6-C-2 AHU-27 AREA C 1 DMDV VAV 06 06 6x6 500 50 310 72 1 0.25 0.46 14 14
MB-6-C-3 AHU-27 AREA C 1 DMDV VAV 08 08 7x8 900 90 430 108 1 0.25 0.19 15 14
MB-6-C-4 THRU MB-6-C-8 AHU-27 AREA C 5 DMDV VAV 06 06 6x6 500 50 240 95 1 0.25 0.27 11 11
MB-6-C-9 AHU-27 AREA C 1 DMDV VAV 10 10 10x11 1400 145 640 160 1 0.25 0.11 17 15
MB-6-C-10 THRU MB-6-C-14 AHU-27 AREA C 5 DMDV VAV 06 06 6x6 500 50 240 95 1 0.25 0.27 11 11
MB-6-C-15 AHU-27 AREA C 1 DMDV VAV 08 08 7x8 900 90 410 102 1 0.25 0.17 15 14
MB-6-C-16 AHU-27 AREA C 1 DMDV VAV 06 06 6x6 500 50 260 65 1 0.25 0.32 13 13
MB-6-C-17 AHU-27 AREA C 1 DMDV VAV 08 08 7x8 900 90 450 180 1 0.25 0.21 17 15
MB-6-C-18 AHU-27 AREA C 1 DMDV VAV 10 10 10x11 1400 145 670 165 1 0.25 0.12 17 15
MB-6-C-19 AHU-27 AREA C 1 DMDV VAV 10 10 10x11 1400 145 800 200 1 0.25 0.16 18 15
MB-6-C-20 AHU-27 AREA C 1 DMDV VAV 08 08 7x8 900 90 440 110 1 0.25 0.2 17 15
MB-6-C-21 AHU-27 AREA C 1 DMDV VAV 04 04 6x6 225 30 140 30 1 0.25 0.36 13 12
MB-6-C-22 AHU-27 AREA C 1 DMDV VAV 06 06 6x6 500 50 170 45 1 0.25 0.14 <10 <10
MB-6-C-23 AHU-27 AREA C 1 DMDV VAV 04 04 6x6 225 30 150 35 1 0.25 0.41 14 14
MB-6-C-24 AHU-27 AREA C 1 DMDV VAV 04 04 6x6 225 30 110 30 1 0.25 0.22 11 < 10
MB-6-C-25 AHU-27 AREA C 1 DMDV VAV 04 04 6x6 225 30 120 30 1 0.25 0.27 11 < 10
MB-6-C-26 AHU-27 AREA C 1 DMDV VAV 08 08 7x8 900 90 520 120 1 0.25 0.42 23 21
MB-6-C-27 AHU-27 AREA C 1 DMDV VAV 12 12 11x13 2000 200 1070 300 1 0.25 0.23 24 19
MB-6-C-28 AHU-27 AREA C 1 DMDV VAV 12 12 11x13 2000 200 1120 300 1 0.25 0.25 25 19
MB-6-C-29 AHU-27 AREA C 1 DMDV VAV 10 10 10x11 1400 145 810 145 1 0.25 0.17 18 15
MB-6-C-30 AHU-27 AREA C 1 DMDV VAV 08 08 7x8 900 90 450 150 1 0.25 0.21 17 15
MB-6-C-31 THRU MB-6-C-33 AHU-27 AREA C 3 DMDV VAV 06 06 6x6 500 50 270 95 1 0.25 0.35 13 13
MB-6-C-34 THRU MB-6-C-37 AHU-27 AREA C 4 DMDV VAV 08 08 7x8 900 90 370 95 1 0.25 0.14 14 12
MB-6-C-38 AHU-27 AREA C 1 DMDV VAV 06 06 6x6 500 50 270 95 1 0.25 0.35 13 13
MB-6-C-39 AHU-27 AREA C 1 DMDV VAV 06 06 6x6 500 50 330 60 1 0.25 0.52 14 15
MB-6-C-40 AHU-27 AREA C 1 DMDV VAV 08 08 7x8 900 90 530 90 1 0.25 0.29 18 16
MB-6-C-41 AHU-27 AREA C 1 DMDV VAV 06 06 6x6 500 50 200 50 1 0.25 0.19 10 10
MB-6-C-42 AHU-27 AREA C 1 DMDV VAV 08 08 7x8 900 90 530 90 1 0.25 0.29 18 16
MB-6-C-43 AHU-27 AREA C 1 DMDV VAV 06 06 6x6 500 50 200 50 1 0.25 0.19 10 10
MB-6-A-1 AHU-34 AREA A 1 DMDV VAV 10 10 10x11 1400 145 915 310 1 0.25 0.22 19 17
MB-6-A-2 AHU-34 AREA A 1 DMDV VAV 08 08 7x8 900 90 380 150 1 0.25 0.15 15 12
MB-6-A-3 AHU-34 AREA A 1 DMDV VAV 10 10 10x11 1400 145 840 230 1 0.25 0.18 18 16
MB-6-A-4 AHU-34 AREA A 1 DMDV VAV 08 08 7x8 900 90 470 120 1 0.25 0.22 17 15
MB-6-A-5 AHU-34 AREA A 1 DMDV VAV 04 04 6x6 225 30 150 40 1 0.25 0.41 14 14
MB-6-A-6 AHU-34 AREA A 1 DMDV VAV 06 06 6x6 500 50 280 70 1 0.25 0.37 13 14
MB-6-A-7 AHU-34 AREA A 1 DMDV VAV 06 06 6x6 500 50 340 83 1 0.25 0.55 14 15
MB-6-A-8 AHU-34 AREA A 1 DMDV VAV 08 08 7x8 900 90 360 90 1 0.25 0.13 14 12
MB-6-A-9 AHU-34 AREA A 1 DMDV VAV 08 08 7x8 900 90 480 90 1 0.25 0.23 17 15
MB-6-A-10 AHU-34 AREA A 1 DMDV VAV 06 06 6x6 500 50 350 83 1 0.25 0.58 14 15
MB-6-A-11 AHU-34 AREA A 1 DMDV VAV 08 08 7x8 900 90 540 120 1 0.25 0.3 18 17
MB-6-A-12 THRU MB-6-A-15 AHU-34 AREA A 4 DMDV VAV 06 06 6x6 500 50 270 95 1 0.25 0.35 13 13
MB-6-A-16 AHU-34 AREA A 1 DMDV VAV 08 08 7x8 900 90 530 90 1 0.25 0.29 18 16
ANEMOSTAT AS STANDARD
MARK TYPE
AIR FLOW
MAX APD
IN. WG MOUNTING
PANEL /
FRAME SIZE
IN.
NECK /
ROUGH
OPENING
SIZE
IN.
NC MODEL FINISH REMARKS
MIN
CFM
MAX
CFM
SD-1 S-VENT 80 140 0.11 CEILING 10.3x10.3 8x8 < 30 SV-432 SELECTED BY ARCHITECT MAXIMUM SECURITY
SD-2 S-VENT 150 310 0.11 CEILING 14.2x14.2 12x12 < 30 SV-432 SELECTED BY ARCHITECT MAXIMUM SECURITY
SD-3 S-VENT 320 520 0.11 CEILING 18.3x18.3 16x16 < 30 SV-432 SELECTED BY ARCHITECT MAXIMUM SECURITY
SD-4 S-VENT 530 790 0.11 CEILING 22.3x22.3 20x20 < 30 SV-432 SELECTED BY ARCHITECT MAXIMUM SECURITY
SD-5 PERFORATED 50 130 0.02 CEILING 24x24 6x6 < 20 PD WHITE
SD-6 PERFORATED 131 220 0.01 CEILING 24x24 8x8 < 20 PD WHITE
SD-7 PERFORATED 221 300 0.02 CEILING 24x24 10x10 < 20 PD WHITE
SD-8 PERFORATED 301 500 0.04 CEILING 24x24 12x12 < 20 PD WHITE
SD-9 PERFORATED QUAD CORE 30 100 0.07 CEILING 6x6 < 20 QCP-S SELECTED BY ARCHITECT
SD-10 PERFORATED QUAD CORE 101 190 0.07 CEILING 8x8 < 20 QCP-S SELECTED BY ARCHITECT
SD-11 PERFORATED QUAD CORE 191 300 0.08 CEILING 10x10 22 QCP-S SELECTED BY ARCHITECT
SD-12 PERFORATED 60 125 0.02 CEILING 24x24 6x6 < 20 PLD-MS SELECTED BY ARCHITECT MINIMUM SECURITY
SD-13 PERFORATED 126 220 0.01 CEILING 24x24 8x8 < 20 PLD-MS SELECTED BY ARCHITECT MINIMUM SECURITY
SD-14 PERFORATED 221 345 0.03 CEILING 10x10 < 20 PLD-MS SELECTED BY ARCHITECT MINIMUM SECURITY
SD-15 PERFORATED 346 500 0.04 CEILING 24x24 12x12 23 PLD-MS SELECTED BY ARCHITECT MINIMUM SECURITY
ER-1 S-VENT 50 90 0.10 CEILING 12.3x11.3 10.4x9.4 < 15 SSV-2-C3 STAINLESS STEEL MAXIMUM SECURITY
ER-2 S-VENT 91 140 0.10 CEILING 14.3x13.3 12.4x11.4 < 15 SSV-2-D4 STAINLESS STEEL MAXIMUM SECURITY
ER-3 EXHAUST REGISTER 25 80 0.03 CEILING 8x4 < 20 35/L/0
ER-4 EXHAUST REGISTER 81 180 0.03 CEILING 8x8 < 20 35/L/0
RR-1 S-VENT 114 200 0.10 CEILING 16.3x15.3 14.4x13.4 < 20 SV-2-E5 SELECTED BY ARCHITECT
RR-2 S-VENT 201 270 0.10 CEILING 16.3x15.3 16.4x15.4 < 20 SV-2-F6 SELECTED BY ARCHITECT
RR-3 S-VENT 271 350 0.10 CEILING 20.3x17.3 18.4x17.4 < 20 SV-2-G7 SELECTED BY ARCHITECT
RR-4 PERFORATED 70 120 0.05 CEILING 24x24 8x6 < 20 3PD SELECTED BY ARCHITECT
RR-5 PERFORATED 121 190 0.05 CEILING 24x24 12x6 < 20 3PD SELECTED BY ARCHITECT
RR-6 PERFORATED 191 280 0.05 CEILING 24x24 10x10 < 20 3PD SELECTED BY ARCHITECT
RR-7 PERFORATED 281 420 0.05 CEILING 24x24 12x12 < 20 3PD SELECTED BY ARCHITECT
RR-8 PERFORATED 421 570 0.05 CEILING 24x24 16x12 < 20 3PD SELECTED BY ARCHITECT
RR-9 PERFORATED 571 770 0.05 CEILING 24x24 16x16 < 20 3PD SELECTED BY ARCHITECT
RR-10 PERFORATED 771 1000 0.05 CEILING 24x24 18x18 < 20 3PD SELECTED BY ARCHITECT
RR-11 PERFORATED 50 90 0.10 CEILING 9.5x9.5 6x6 < 20 ASSG-RR SELECTED BY ARCHITECT RISK RESISTANT
RR-12 PERFORATED 91 170 0.10 CEILING 11.5x11.5 8x8 < 20 ASSG-RR SELECTED BY ARCHITECT RISK RESISTANT
RR-13 PERFORATED 171 270 0.10 CEILING 13.5x13.5 10x10 < 20 ASSG-RR SELECTED BY ARCHITECT RISK RESISTANT
RR-14 PERFORATED 271 400 0.10 CEILING 15.5x15.5 12x12 < 20 ASSG-RR SELECTED BY ARCHITECT RISK RESISTANT
RR-15 PERFORATED 401 560 0.10 CEILING 17.5x17.5 14x14 < 20 ASSG-RR SELECTED BY ARCHITECT RISK RESISTANT
RR-16 PERFORATED 561 740 0.10 CEILING 19.5x19.5 16x16 < 20 ASSG-RR SELECTED BY ARCHITECT RISK RESISTANT
RR-17 PERFORATED 741 1040 0.10 CEILING 23.5x23.5 20x20 < 20 ASSG-RR SELECTED BY ARCHITECT RISK RESISTANT
RR-18 PERFORATED 60 150 0.02 CEILING 24x24 6x6 < 20 3RPLD-MS SELECTED BY ARCHITECT MINIMUM SECURITY
RR-19 PERFORATED 151 270 0.03 CEILING 24x24 8x80 < 20 3RPLD-MS SELECTED BY ARCHITECT MINIMUM SECURITY
RR-20 PERFORATED 271 420 0.04 CEILING 24x24 10x10 < 20 3RPLD-MS SELECTED BY ARCHITECT MINIMUM SECURITY
RR-21 PERFORATED 421 600 0.03 CEILING 24x24 12x12 < 20 3RPLD-MS SELECTED BY ARCHITECT MINIMUM SECURITY
RR-22 PERFORATED 601 820 0.04 CEILING 24x24 14x14 < 20 3RPLD-MS SELECTED BY ARCHITECT MINIMUM SECURITY
RR-23 PERFORATED 821 1070 0.04 CEILING 24x24 16x16 < 20 3RPLD-MS SELECTED BY ARCHITECT MINIMUM SECURITY
NOTES:NOTES:
1. PROVIDE HIGH PERFORMANCE INTERNAL MIXING BAFFLE WITH 1:20 MIXING RATIO.
2. ALL PERFORMANCE BASED ON TESTS CONDUCTED IN ACCORDANCE WITH ASHRAE 130-2008 AND AHRI 880-2008.
3. ALL NC LEVELS DETERMINED USING AHRI 885-2008 APPENDIX E.
4. DATA BASED ON 1" INLET STATIC PRESSURE AND 0.25" DOWNSTREAM STATIC PRESSURE.
2. PROVIDE UNIT MOUNTED TOGGLE DISCONNECT, 120/24 V TRANSFORMER, FACTORY MOUNTED DDC CONTROLS (INCLUDING ACTUATOR), CENTER AVERAGING
INLET VELOCITY CENTER AND FOIL FACED HOSPITAL GRADE STERI-LOC INSULATION.
3. DDC CONTROLS SHALL BE CAPABLE OF OPERATING STANDALONE AS WELL AS BTL CERTIFIED BACNET CAPABLE WHEN WIRED FOR BACNET COMMUNICATION.
4. UNITS CONTROLS BY OWNER'S ATC/BAS CONTRACTOR.
5. PROVIDE CLEARANCE AROUND CONTROL BOX PER NEC REQUIREMENTS.
6. CONTRACTOR TO COORDINATE LEFT HAND OR RIGHT HAND CONTROL LOCATION.
7. INLET SIZES ARE NOMINAL, REFERENCE CATALOG FOR EXACT INLET DIMENSIONS.
8. UNITS SHALL BE CAPABLE OF TURNING DOWN TO MINIMUM VELOCITIES OF 250 FPM MAINTAINING THE ACCURACY OF ±5%.
1. ALL BORDER TYPES SHALL BE COORDINATED WITH ARCHITECTURAL DRAWINGS AND APPROVED BY ARCHITECT.
2. FOR EXACT LOCATIONS OF CEILING AIR OUTLETS, SEE ARCHITECTURAL REFLECTED CEILING PLANS. COORDINATION IS REQUIRED
PLUMBING DEMOLITION & ALTERATION NOTES PLUMBING INSTALLATION CRITERIA
EACH BIDDER SHALL VISIT THE SITE AND BECOME INFORMED AS TO THE
CONDITION OF THE PREMISES AND THE EXTENT AND CHARACTER OF WORK
REQUIRED.
1. PROVIDE ROUGH-IN AND FINAL CONNECTIONS FOR ALL PLUMBING
FIXTURES INCLUDING WASTE, VENTS, HOT AND COLD WATER, AND
PROVIDE ALL PLUMBING WORK NECESSARY TO MAKE FXTURES, AND
EQUIPMENT ENTIRELY OPERABLE AND ACCEPTABLE TO LOCAL HEALTH
AND BUILDING OFFICIALS.
2. ALL VISIBLY EXPOSED PIPE TO EQUIPMENT SHALL BE CHROME PLATED
BRASS.
3. PROVIDE INDIVIDUAL SHUT-OFF VALVES FOR ALL PLUMBING FIXTURES AND
EQUIPMENT.
4. PROVIDE TRAPS ON ALL WASTE PIPING FROM PLUMBING FIXTURES AND
EQUIPMENT.
5. COORDINATE POSITION OF SLEEVES AND OPENINGS THROUGH FLOOR
WITH THE GENERAL CONTRACTOR.
6. PROVIDE VACUUM BREAKERS AND CHECK VALVES FOR THE PLUMBING
FIXTURES WHERE AND WHEN REQUIRED BY CODE.
7 ALL PIPING AND EQUIPMENT SHALL BE SUBSTANTIALLY SUPPORTED FROM
THE BUILDING STRUCTURE. HANGER AND SUPPORTS SHALL BE
SPECIFICALLY APPROVED FOR USE IN PLUMBING SYSTEMS.
A. WHERE OVERHEAD CONSTRUCTION DOES NOT PERMIT FASTENING
OF HANGER RODS IN REQUIRED LOCATIONS, PROVIDE ADDITIONAL
STEEL FRAMING AS REQUIRED AND APPROVED.
B. NO PLUMBING PIPING SHALL BE HUNG FROM THE PIPING OF OTHER
TRADES OR DUCTWORK. HANGERS SHALL BE OF HEAVY
CONSTRUCTION SUITABLE FOR THE SIZE OF PIPE TO BE SUPPORTED.
8 ALL HORIZONTAL PIPING RUNS WILL BE AT THE HIGHEST PRACTICAL
ELEVATION AND NOT LESS THAN 6" ABOVE THE FLOOR SO AS TO PROVIDE
CLEARANCE.
1. ALL PLUMBING FIXTURES TO BE REMOVED SHALL BE TURNED OVER TO THE
OWNER. THEY SHALL NOT BE REMOVED FROM THE PREMISES OR DISPOSED
OF WITHOUT THE OWNER'S APPROVAL.
2. ALL PIPING TO BE REMOVED SHALL BE PROPERLY PLUGGED OR CAPPED SO
THAT UPON COMPLETION OF ALL NEW WORK. NO ABANDONED PIPING SHALL
REMAIN AFTER DEMOLITION IS COMPLETED.
3. NO DEAD ENDS SHALL BE LEFT ON ANY PIPING UPON COMPLETION OF THE
PROJECT.
4. EXISTING EXPOSED PIPING NOT TO BE REUSED AND NOT SPECIFICALLY
NOTED OR SHOWN ON DRAWINGS TO BE ABANDONED SHALL BE COMPLETELY
REMOVED.
5. THE EXISTING SYSTEMS SHALL BE LEFT IN PERFECT WORKING ORDER UPON
COMPLETION OF ALL NEW WORK.
6. LOCATIONS AND SIZES OF EXISTING PIPING ARE APPROXIMATE. EXACT SIZES
AND LOCATIONS OF ALL EXISTING PIPING SHALL BE VERIFIED AT THE SITE.
7. NO REMOVED EXISTING PIPING, EQUIPMENT, ETC. SHALL BE REUSED.
8. ALL EXISTING EXPOSED, UNNECESSARY PIPING RELATED TO WORK BEING
DONE SHALL BE COMPLETELY REMOVED.
9. THIS CONTRACTOR SHALL NOT INTERRUPT ANY OF THE SERVICES OF THE
EXISTING FACILITY, NOR INTERFERE WITH THE SERVICES IN ANY WAY WITHOUT
PRIOR POSTED NOTICE OF AT LEAST THE EXPRESS PERMISSION OF THE
OWNER IN WRITING. 72 HOURS & SUCH INTERRUPTIONS AND INTERFERENCES
SHALL BE COORDINATED WITH THE GENERAL MADE AS BRIEF AS POSSIBLE AND
ONLY AT THE TIME CONTRACTOR, OWNER & RESIDENTS & STATED BY THE
OWNER, THE BUILDING IS TO REMAIN OPERATIONAL THROUGHOUT
CONSTRUCTION.
10. UNDER NO CIRCUMSTANCES SHALL THIS CONTRACTOR OR HIS WORKMEN
BE PERMITTED TO USE ANY PART OF THE BUILDING AS A SHOP, EXCEPT PARTS
DESIGNATED BY THE OWNER FOR SUCH PURPOSES.
11. REROUTE OR REMOVE ALL EXISTING PIPING WHERE NECESSARY TO AVOID
NEW EQUIPMENT, STRUCTURAL, MASONRY OR CARPENTRY WORK AS
REQUIRED BY THE PROPOSED ALTERATION.
12. ADD OR REPLACE VALVES OR FITTING AS REQUIRED, INCLUDING THE MAIN
LINES, TO PROVIDE TEMPORARY SERVICE TO ADJACENT AREAS DURING THE
PERIOD OF CONSTRUCTION.
SHUT-OFF VALVE
SYMBOL
PLUMBING SYMBOLS AND ABBREVIATIONS
DESCRIPTION
EXISTING SHUT-OFF VALVE
CLEVIS
HANGER
DOUBLE
LOCKNUTS
THREADED
ROD
NOTES:
1. HANGER, ROD & INSERT SHALL BE
DIPPED IN ZINC CHROMATE
PRIMER PRIOR TO INSTALLATION
2. REFER TO SPECIFICATION FOR
HANGER SPACING AND ROD SIZE.
GALVANIZED METALSHIELD
CLEVIS
HANGER
DOUBLE
LOCKNUTS
C OF
PIPE
LOAD BEARING
CALCIUM SILICATE
INSULATION AT ALL
HANGER POINTS
INSULATED HOT PIPING (ABOVE 16O°F)
INSULATED COLD AND
INSULATED HOT PIPE
E
SHALL NOT BE USED)
(ASBESTOS OR FIBERGLASS
FIRE RESISTIVE MATERIAL
OR OTHER EQUALLY APPROVED
DEPTH WITH MINERAL WOOL
ALL SPACES PACKED FULL
BARE PIPE
C OF
PIPE
HOT WATER RETURN PIPING (HWR)
TEMPERED WATERT T
LAVATORY
WATER CLOSET
1 1/2"
(S/W)
4"
1/2"1 1/2" 1/2"
(V) (CW)
2" -
(HW)
PLUMBING FIXTURE CONNECTION SCHEDULE
LEGEND PLUMBING FIXTURE SOIL/
WASTE
CONNECTION SIZE - INCHES
COLD
WATER
VENT HOT
WATER
REMARKS
P-3
P-2
P-1
1-1/4"
SHOWER 3/4" -3/4"1 1/2"2"
FLOOR MOUNTED
BACK OUTLET
WATER CLOSET 4" 2" -P-1A 1-1/4" IN PATIENT ROOM
LAVATORY 1 1/2" 1/2"1 1/2"P-2A IN PATIENT ROOM
SINK 3/4"P-4 3/4"1 1/2"2"
MOP RECEPTOR 3/4"P-5 3/4"1 1/2"3"
P-6 1 1/2"2"LAUNDRY TUB 3/4" -3/4"
P-3A SHOWER 3/4" IN PATIENT ROOM3/4"1 1/2"2"
(TW)
TEMPERED
WATER
1/2"
AFFWALL 2294.011EC
DESCRIPTION
MODEL: CADET 1674
LUCERN 0356.421P-2 LAVATORY
DESIGNATION
FIXTURE
P-1 WATER CLOSET
MODEL No.
AMERICAN STANDARD
MANUFACTURER
(OR EQUAL)
AMERICAN STANDARD
P-3 STAFF SHOWER
SLOAN OPTIMA ETF-700 SLOAN
SENSOR ACTIVATED ELECTRONIC GOOSENECK HAND
WASHING FAUCET. LAMINAR FLOW SPRAY HEAD EFT-687, 1.5
GPM. SLOAN MIXING VALVE MIX-60A. SHALL BE HARD WIRED.
SLOAN ROYAL 111 SLOAN
AMERICAN STANDARD
VITREOUS CHINA, LOW CONSUMPTION 1.6 GPF., WALL
MOUNTED, COLOR WHITE.
MODEL: REVAL AMERICAN STANDARD "QUICK-CLOSE" SEAT WITH "QUICK-RELEASE" FUNCTIONALITY
FLOOR MOUNTED, REAR DRAIN OUTLET. PROVIDE WITH
PIEZO TOUGH ACTIVATION BUTTON MODEL PBA051-2BA
SINGLE CENTER HOLE WITH OVERFLOW, VITROUS CHINA,
WALL HUNG LAVATORY.
MODEL: Z-1231 ZURN ZURN CONCEALED ARMS CARRIER
ELKAY
MODEL: 201-AGN8AE3-31CP CHICAGO FAUCET
MODEL: LRDAF221955
DECK MOUNTED, 8" FIXED CENTERS, 2.2 GPM, 4"
VANDAL PROOF WRISTBLADE HANDELES HANDLE.
MODEL: TSB-300 FIAT PRODUCTS TERRAZZO RECEPTOR 32"x12". tHE DRAIN BODY PLATE #874
SHALL BE CAST BRASS CADIUM PLATED COMPLETE WITH
CAST BRASS LOCKOUT, TWO NEOPREME GASKETS AND A
COMBINATION REMOVAL, STAINLESS STEEL DOME STRAINER
AND LINT BASKET. THE DOME STRAINER SHLL BE ATTACHED
WITH STAINLESS STEEL PHILLIPS HEAD SCREWS.
MODEL: AP200 AQUA PURE PROVIDE ON STAFF PANTRY SINK. FULL FLOW UNDER SINK
FILTER SYSTEM. HIGH COMPACT SEDIMENT CARTRIDGE.
CARBON MEDIA.
MODEL: CWC151-AST
MODEL: Z-1203 AND Z-1204 ZURN COMBINATION WATER CLOSET CARRIER AND
DRAINAGE FITTING. FEET BOLTED TO
CONSTRUCTION.
SLOAN OPTIMA ETF-700 SLOAN
SENSOR ACTIVATED ELECTRONIC GOOSENECK HAND
WASHING FAUCET. LAMINAR FLOW SPRAY HEAD EFT-687, 1.5
GPM. SLOAN MIXING VALVE MIX-60A.
HEAVY- DUTY LIGATURE RESISTANT SANIWAVE RX UNIT
MADE FROM ANTIMICROBIAL, SOLID SURFACE. VANDAL
RESISTANT PIEZO TOUCH BOTTONS PBA051-2BA
CONTROLLED BY WATER CONTROLLER.
P-1A PATIENT WATER CLOSET
P-2A PATIENT
LAVATORY
WALLGATE BY INTERSAN
MODEL: WHB-200-ADA WALLGATE BY INTERSAN
PRESSURE BALANCING SHOWER SET. EASY-CLEAN SHOWER
HEAD, POLISHED CHROME FINISH, CAST BRASS BODY,
WASHERLESS CERAMIC DISC VALVE CARTRIDGE WITH
VOLUME AND TEMPERATURE CONTROL HOT LIMIT SAFETY
STOP. PRESSURE BALANCING VALVE MAINTAINS OUTPUT
TEMPERATURE IN RESPONSE TO CHANGE IN RELATIVE HOT
AND COLD SUPPLY PRESSURE.
PIPING CONTINUATION
PIPING CONTINUATION
PIPING CONTINUATION
MODEL: SMVA09 PROPORTIONALLY ADJUSTABLE TEMPERATURE CONTROL
WITH BUILT-IN THERMOSTATIC MIXING VALVE. INCLUDES AN
ELECTRONICALLY OPERATED PIEZO ACTIVATION BUTTON.
PIEZO TOUCH BUTTON ACTIVATES SOLENOID VALVE THAT IS
CONTROLLED BY WATER CONTROLLER. PROVIDE WITH
LIGATURERESISTANT SHOWER HEAD MODEL 40691 GAVIN
ENGINEERING BY INTERSAN. HIDDEN WALL ANCHORING FOR
SECURITY. HIGH POLISH CHROME ON BRASS BODY.
P-4 PATIENT SHOWER WALLGATE BY INTERSAN
P-4 SINK
MED DISPENSARY
NOURISMENT
PANTRY
EXAM
STAINLESS STEEL SINK, 22"x19"x5" SINGEL BOWL, TOP
MOUNT, 304 18 GAUGE, SOUND DEADENING FULLY SPRAY
SIDES AND BOTTOM.
P-5 MOP RECEPTOR
CHROME PLATED TYPE FAUCET, STOPS IN SHANKS, SPOUT
WITH HOSE END, BUCKET HOOK AND TOP BRACE,
ADJUSTABLE THREADED FLANGES, AMERICAN STANDARD
#7837.024 VACUUM BREAKER INSTALLED 6'-0" ABOVE FINISHED
FLOOR, WALL ESCUTCHEONS, CHROME PLATED EXPOSED
PIPING.
MODEL: 8345.100 AMERICAN STANDARD
MODEL: SF-1-F FIAT PRODUCTS SINGLE COMPARTMENT LAUNDRY TUB, OVERALL OUTSIDE
DIMENSIONS 20"x23-7/8"x14-3/8"; MOLDED DRAIN, PLASTIC
STOPPER AND TAILPIECE NUT AND WASHER, 4" LEDGE
INTEGRALLY MOLDED AT BACK OF THEUNIT INCLUDES TWO
(2) SOAP DISH LOCATIONS; HOLES 4" ON CENTER SUPPORTED
WITH FACTORY-FURNISHED WHITE BACKED ENAMEL STEEL
ANGLE LEGS.
P-6 LAUNDRY TUB
LAUNDRY SINK FAUCET, 4" CENTERS, 5" PLAIN END SWING
SPOUT REACH, 2.2 GPM..
MODEL: CORALAIS
K-15270
KOHLER
FOR CONTROL OF PATIENT ROOM SHOWERS AND
LAVATORIES VIA SOLENOID VALVES. FULLY PROGRAMABLE
EIGHT CHANNEL ELECTRONIC CONTROLLER TO MANAGE ALL
SANITARY WARE WITHIN TWO ADJACENT ROOMS OR SINGEL
ROOM. WIRING UNDER PLUMBING WORK EXCEPT POWER
WIRING. WATER CONTROL IS CONTROLLED BY HOSPITAL
STAFF ONLY TO CONTROL SHOWERS AND LAVATORIES.
REFER TO ACTUAL BOOK SPECIFICATION FOR FURTHER INFORMATION AND DETAILS SPECIFICATION OF ALL PLUMBING FIXTURES AND ACCESSORIES.
WATER CONTROLLER MODEL: 700 WDC-200
(FOR 2 ROOMS)
MODEL: 700 WDC-400
(FOR 1 ROOM)
WALLGATE BY INTERSAN
EXPOSED WATER CLOSET FLUSHOMETER 1.6 GPF
SHALL BE HARD WIRED.
CONNECT NEW 4" S
TO EXIST 4" S
CONNECT NEW 4" S
TO EXIST 4" S
CONNECT NEW 4" S
TO EXIST 4" S
CONNECT NEW 4" S
TO EXIST 4" S
3" W UP TO FD
4"
3"
4"
CONN. NEW 2"C.W.,
1"H.W. AND 3/4"H.W.R.
TO EXISTING
CONN. NEW
2"C.W., 3/4"H.W. AND
1/2"H.W.R. TO EXISTING
CONN. NEW
3/4"H&C.W. AND
1/2"H.W.R. TO EXISTING
CONN. NEW
3/4"H&C.W. AND
1/2"H.W.R. TO EXISTING
1"3/4"
1/2"
3/4"
1-1/2" 3/4"
2"
2"
1-1/2" V UP
3" W UP
3"
3" W UP TO FD
4" S UP
2" W UP
2" W UP
(2) 1-1/2" V UP
3" W UP TO FD
4" S UP
3" W UP
2" W UP
4"
4"
3" W UP TO FD
2" W UP
1-1/2" V. UP
3"
2"
CONN
2" CW
1-1/4" HW
3/4" HWR
TO EXIST
RISERS
1-1/2" W. UP
2" W. UP
4" S. UP
1-1/2" V. UP
1-1/2" V. UP
3" W UP TO FD
4" S. UP
1-1/2" V. UP
1-1/2" V. UP
1-1/2" W. UP
2" W. UP
2" W. UP
1-1/2" W. UP
3" W. UP TO FD
1-1/2" V. UP
4" S. UP
1-1/2" V. UP
1-1/2" V. UP
4" S. UP
1-1/2" V. UP
4" S. UP
1-1/2" V. UP
1-1/2" V. UP
3" W. UP TO FD
2" W. UP 2" W. UP
3" W. UP TO FD
1-1/2" W. UP 1-1/2" W. UP 1-1/2" W. UP 1-1/2" W. UP
2" W. UP 2" W. UP
2" W. UP
4" S. UP
1-1/2" V. UP
1-1/2" V. UP
1-1/2" V. UP
3" W. UP TO FD
3" W. UP TO FD
2" W UP
1-1/2" W. UP
1-1/2" W. UP
2" W. UP
2" W. UP
4" S. UP4" S. UP
1-1/2" W. UP
3" W. UP TO FD
3" W. UP TO FD
2" W. UP
4" S. UP1-1/2" W. UP
2" W. UP
4" S. UP
1-1/2" W. UP
3" W. UP TO FD
2" W. UP
4" S. UP
1-1/2" W. UP
3" W. UP TO FD
1-1/2" W. UP
2" W. UP
4" S. UP
1-1/2" V. UP
1-1/2" W. UP
3" W. UP TO FD3" W. UP TO FD
1-1/2" W. UP 4" S. UP
1-1/2" V. UPCONN
2" CW
1-1/4" HW
3/4" HWR
TO EXIST
RISERS
2" W. UP
1-1/2" W UP
1-1/2" W UP
2" W UP
2" CW UP
1-1/4" HW UP
3/4" HWR UP
2" CW UP
1-1/4" HW UP
3/4" HWR UP
2" W UP
2" W. UP
4" W. UP
4"S DN
2"V RISE
2"
1 1/2"CW DP
3/4"HW DP
3"S DN
3/4"H&CW DP
4"S DN
2"V RISE
1 1/2"CW DP
3/4"HW DP
2"W DN
3"W DN
(2) 1 1/2"V RISE & DN
3/4"H&CW DP
1 1/2"V RISE
& DN
3/4"H&CW DP
1 1/2"W DN
1 1/2"V RISE
3/4"H&CW DP
2"W DN
EXIST. TOILET
TO REMAIN
4"S DN
2"V RISE
1 1/2"CW DP
CONN. NEW 2"V,
TO EXISTING
NEW 2"C.W., 3/4"H.W.
AND…
This is the start of the file's text. The full file is on GovTribe.