This is an architectural plan document for fire and life-safety corrections at Santiam Correctional Institution (SCI), a state facility operated by the Oregon Department of Corrections located at 4005 Aumsville Highway SE, Salem, Oregon 97317. The project (No. 2026-013) addresses fire and life-safety deficiencies identified by the State Fire Marshal and involves repair and replacement of certain doors, installation of fire/smoke dampers in existing ducts within smoke partitions, and addition of magnetic hold-open devices interconnected to the existing fire alarm system. The facility is a three-story Type I-A construction building with a total area of approximately 71,139 square feet (24,056 sf basement, 23,568 sf ground floor, 23,568 sf second floor), classified as I-3 (Condition 2) correctional center occupancy. The scope includes comprehensive door replacement and upgrading throughout all three levels, with detailed specifications for fire-rated doors, frames, hardware assemblies, and related life-safety improvements documented across multiple sheets including site plan, floor plans for all three levels, schedules, and mechanical and electrical drawings.

The project documents specify fire resistance rating requirements per the 2025 Oregon Structural Specialty Code (OSSC), including 3-hour primary structural frames and bearing walls, 2-hour floor construction, and 1.5-hour roof construction, with automatic sprinkler systems per NFPA 13 (existing), fire alarm systems per OSSC Section 907, and exit access travel distance requirements of maximum 200 feet. The door schedule details over 100 doors across all levels with specifications for width, height, material, finish, fire ratings ranging from 20 to 60 minutes, and hardware requirements. Hardware schedules (HW-00 through HW-10) specify hinges, closers, locksets, gasketing sets, door sweeps, and magnetic hold-open devices. The project architect is Studio 3 Architecture, Inc. (Scott McDonald, AIA), with mechanical and electrical engineering by MFIA, Inc. The plans bear a date of 05/29/2026 and include requirements for third-party fire door inspection to verify compliance with minimum fire ratings, with contractor responsibility for corrections if inspections fail.

View the file

Other files

File Type Posted
Pre-Bid Pictures~11.pdf PDF
Check Off sheet ITB~18.pdf PDF
17813 Summary of Work.pdf PDF
17813_Plan Holder List.pdf PDF
Asbestos and Lead Paint Report.pdf PDF
17813 ITB_GTC_SGC_SPECS.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S SS S

1 11 1 1

1 11 1

S SS S

1 1

1 1

1 1

1 1

1 1

S S

S

S

S SS S

S

S S

1 1

1 1

1 1

1 1

1 1

S S

S S

S

S

S S

S S

S

S S

1 1

1 11

S S

S S

S

S

S S

S S

S

1 1

S

S

DOOR NUMBER

SECTION REFERENCE:

DETAIL REFERENCE:

ELEVATION REFERENCE:

PLAN NOTE DESIGNATION

F

XXXX

XXXX

ROOM

SIM

A2.5X

A

B

C

D

A3.1X

SIM

100 A

X

A5.X

X

A3.1X

WALL TYPE MARK:

ROOM TITLE + NUMER:

WINDOW TYPE:

W-X

ELEVATION DATUM:

As4a

WALL OR PARTITION

CONSTRUCTION TYPE.

SEE LEGEND.

ROOM NAME

ROOM NUMBER

PLAN OR SIDE NOTE

NUMBER

MARK OR DIAGONAL NOTE

NUMBER

REVISION NUMBER

DOOR SIZE OR NUMBER

REFER TO WINDOW

ELEVATIONS SHOWN ON

DRAWINGS A5.1X

100.00' F.F.E.

ELEVATION

ELEVATION DATUM

LOCATION:

FILLED ARROW DENOTES

BUILDING SECTION

OPEN ARROW DENOTES

WALL SECTION/DETAIL

DETAIL NUMBER

SHEET NUMBER

SIDE NOTE IF REQUIRED

ELEVATION NUMBER OR

DESIGNATION AS OCCURS

SHEET NUMBER

DETAIL NUMBER

SHEET NUMBER

SIDE NOTE IF REQUIRED

DETAIL CUT LOCATION IF

SHOWN

SYMBOL LEGEND:

SITE VICINITY IMAGE:

SITE IMAGE:

CODE PLAN LEGEND:

SMOKE BARRIER

1-HOUR FIRE PARTITION FOR CORRIDORS.

20 MINUTE DOORS PER OSSC 716

1-HOUR FIRE BARRIER FOR SHAFTS/STAIRS.

60 MINUTE DOORS PER OSSC 716

EGRESS PATH LOCATIONS.

INCIDENTAL USE AREA- MECHANICAL/ELECTRICAL ROOMS.

• GAS BOILERS- 2 @ 1,500,000 BTU/HR

• 600A ELECTRICAL SERVICE.

INCIDENTAL USE AREA- LAUNDRY ROOM.

STAIR NOT REQUIRED FOR MEANS OF

EGRESS. COMMUNICATING STAIR ONLY.

STAIR

STAIR

STAIRSTAIR

ELEV

INCIDENTAL USE AREA-

LAUNDRY ROOM.

INCIDENTAL USE AREA-

LAUNDRY ROOM.

SLEEPING AREA

MINIMUM 2 SMOKE COMPARTMENTS

PER STORY PER OSSC 408.6

SLEEPING AREA

MINIMUM 2 SMOKE COMPARTMENTS

PER STORY PER OSSC 408.6

STAIR NOT REQUIRED FOR MEANS OF

EGRESS. COMMUNICATING STAIR ONLY.

STAIR

STAIR

STAIRSTAIR

ELEV

STAIR NOT REQUIRED FOR MEANS OF

EGRESS. COMMUNICATING STAIR ONLY.

STAIR

STAIR

STAIRSTAIR

ELEV

INCIDENTAL USE AREA-

LAUNDRY ROOM.

INCIDENTAL USE AREA-

LAUNDRY ROOM.

SLEEPING AREA

MINIMUM 2 SMOKE COMPARTMENTS

PER STORY PER OSSC 408.6

SLEEPING AREA

MINIMUM 2 SMOKE COMPARTMENTS

PER STORY PER OSSC 408.6

AREA OF OFFICE WING +/- 1,475

SF @ 150 SF/OCC = 10 OCC.

TRAVEL DISTANCE TO EXIT = 96 FT

FROM MOST REMOTE POINT.

(OSSC TABLE 1006.2.1).

PROJECT NAME: SANTIAM CORRECTIONAL INSTITUTION - FIRE/LIFE SAFETY CORRECTIONS

ADDRESS: 4005 AUMSVILLE HWY SE, SALEM, OR 97317

PROJECT No: 2026-013

GOVERNING CODES:

• Structural - Life Safety: 2025 Oregon Structural Specialty Code (OSSC)

USE AND OCCUPANCY CLASSIFICATION:

• "I-3" (Condition 2) "Correctional Center" Section 308.4.2

CONSTRUCTION TYPE:

• Type I-A (Assumed)

SPRINKLERS:

• NFPA 13 (Existing)

OCCUPANCY SEPARATIONS: per Section 508.3:

• Project complies with requirements for non-separated uses therefore occupancy separations not required.

ALLOWABLE HEIGHT CALCULATIONS:

• Allowable Height per Table 504.3 = unlimited.

• Actual Building Height to top of parapet = +/- 40 ft. (estimated)

ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE:

• Allowable Number of Stories per Table 504.4 = unlimited.

• Actual Number of Stories = 3 stories.

ALLOWABLE AREA CALCULATIONS:

• Allowable Area per Floor per Table 506.2 = unlimited.

ACTUAL AREA PER FLOOR:

• LEVEL 00: ( Basement ) = 24,056 s.f.

• LEVEL 01: ( Ground Floor ) = 23,568 s.f.

• LEVEL 02: ( Second Floor ) = 23,568 s.f.

• TOTAL: = 71,139 s.f.

FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS IN HOURS per Table 601

• Primary Structural Frame Including Columns, and Girders: 3 hrs

• Bearing Walls, Exterior: 3 hrs

• Bearing Walls, Interior: 3 hrs

• Non-bearing Walls and Partitions, Interior: 0 hrs

• Floor Construction Including supporting beams and joists: 2 hrs

• Roof Construction: 1.5 hrs

Note: All existing structural members, bearing walls, floors, etc. are cast in place concrete of adequate thickness to provide required rating of building elements for the assumed construction type.

FIRE RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION

DISTANCE per Table 705.5

• Exterior Walls: < 5' to property line 1 hrs

• Exterior Walls: > 5' but < 10' to property line 1 hrs

• Exterior Walls: > 10' but < 30' to property line 1 hrs

• Exterior Walls: ≥30' to property line 0 hrs

Note: Fire separation distance is greater than 30 ft for the entire building perimeter.

FIRE PROTECTION SYSTEMS:

• Automatic Sprinkler System required, per OSSC Section 903

• Portable Fire Extinguisers required per OFC Section 906. (Not a Building Code Requirement).

• Fire Alarm System is required per OSSC Section 907, Paragraph 907.2.2.

COMMON PATH OF TRAVEL:

• Common path of travel maximum is 100'-0" per paragraph 1006.2.1.

EXIT ACCESS TRAVEL DISTANCE:

• Maximum travel distance is 200'-0" per table 1017.2.

CORRIDORS:

• 1-Hour Fire Partition per OSSC 1020

EXIT STAIRS & SHAFT ENCLOSURES:

• 1-Hour Fire Barrier per OSSC 713.4 & 1023

CODE REVIEW:

PROJECT SUMMARY:

THIS PROJECT SEEKS TO CORRECT FIRE/LIFE-SAFETY DEFICIENCIES NOTED

BY THE STATE FIRE MARSHAL. SPECIFICALLY, REPAIR AND REPLACEMENT OF

CERTAIN DOORS. ADDITIONALLY, THESE DRAWINGS, ONCE APPROVED

FOR PERMIT, SHALL MEMORIALIZE THE REQUIRED WALL AND DOOR

RATINGS FOR FUTURE REFERENCE. SCOPE ALSO INCLUDES ADDITION OF

FIRE/SMOKE DAMPER FOR EXISTING DUCT IN SMOKE PARTITION AND

MAGNETIC HOLD-OPEN DEVICES INTERCONNECTED TO THE EXISTING

FIRE ALARM SYSTEM.

Copyright © 2025, STUDIO 3 ARCHITECTURE, INC.

SHEET

PROJECT #

DATE:

REVISIONS:

G0.01

S A

N T

IA

M C

O R R E C

T

IO

N A

L I

N S T

IT

U T

IO

N

F

IR

E

L

IF

E S A

F E T Y C

O R R E C

T

IO

N S F

O R

A U

M S V

IL

L E H

W Y S

E S A

L E M

O

R

05/29/2026

2026-013

COVER SHEET

OWNER:

OREGON DEPARTMENT OF CORRECTIONS

Contact: Rachael Halstead-Jeffreys P: 503.779.7937

E: rachael.r.halstead-jeffreys@doc.oregon.gov

ARCHITECT:

STUDIO 3 ARCHITECTURE, Inc.

275 Court Street NE Salem OR 97301 P: 503.390.6500

Project Architect: Scott McDonald, AIA E: Scott@studio3architecture.com W: www.studio3architecture.com

MEP:

MFIA, Inc.

2007 SE Ash Street, Portland, OR 97214 P: 503.234.0548 Mark Denyer, PE

E: mark.denyer@mfia-eng.com

SHEET # SHEET NAME ISSUE DATE REVISION DATE

GENERAL DRAWINGS

G0.01 COVER SHEET 05/29/2026

ARCHITECTURAL DRAWINGS

A1.01 SITE PLAN 05/29/2026

A1.20 LEVEL 00 - FLOOR PLAN 05/29/2026

A1.21 LEVEL 01 - FLOOR PLAN 05/29/2026

A1.22 LEVEL 02 - FLOOR PLAN 05/29/2026

A6.01 SCHEDULES 05/29/2026

MECHANICAL DRAWINGS

M2.00 MECHANICAL FLOOR PLAN 05/29/2026

ELECTRICAL DRAWINGS

E2.00 ELECTRICAL FLOOR PLAN 05/29/2026

E2.01 ELECTRICAL FLOOR PLAN 05/29/2026

SANTIAM CORRECTIONAL INSTITUTION

FIRE & LIFE-SAFETY CORRECTIONS

4005 AUMSVILLE HWY SE, SALEM, OR 97317

PROJECT TEAM:

DRAWINGS LIST:

3/64" = 1'-0"

CODE REVIEW - LEVEL 00

3/64" = 1'-0"

CODE REVIEW - LEVEL 01

3/64" = 1'-0"

CODE REVIEW - LEVEL 02

0' 32' 64'8' 16'

0' 32' 64'8' 16'

0' 32' 64'8' 16'

PR

O

JE

C T

LO

C

AT

IO

N

AU

M

SVILLE HW

Y SE

PARKING LOT

PA

RK

IN

G L O

T

PARKIN

G

LO

T

PARKIN

G

LO

T

BASEBALL FIELD

EX

IS

TI

N G

BU

ILD

IN

G

EX

IS

TI

N G

B U

ILD

IN

G

EX

IS

TI

N G

B U

ILD

IN

G

EX

IS

TI

N G

B U

ILD

IN

G

EXISTIN

G

BUILDIN

G

EXISTIN

BUILDIN

Copyright © 2025, STUDIO 3 ARCHITECTURE, INC.

SHEET

PROJECT #

DATE:

REVISIONS:

A1.01

S A

N T

IA

M C

O R R E C

T

IO

N A

L I

N S T

IT

U T

IO

N

F

IR

E

L

IF

E S A

F E T Y C

O R R E C

T

IO

N S F

O R

A U

M S V

IL

L E H

W Y S

E S A

L E M

O

R

05/29/2026

2026-013

SITE PLAN

1" = 80'-0"

SITE PLAN

N 0' 40' 80' 240'160'15'

NOTE: SITE PLAN SHOWN IN A GENERAL WAY BASED ON SATELLITE IMAGERY.

NO CHANGES TO SITE PLAN ARE PROPOSED.

S SS S

1 11 1 1

1 11 1

S SS S

1 1

1 1

1 1

1 1

1 1

S S

S

S

S SS S

S

S S

FLOOR PLAN NOTES:

1 REPLACE COILING COUNTERTOP DOOR WITH NEW

MANUALLY OPERATED COILING DOOR PER

SPECIFICATIONS. DOOR SHALL HAVE FUSIBLE LINK

AND FIRE ALARM CONNECTION.

2 EXISTING GLASS BLOCK WINDOW ASSEMBLY TO

REMAIN. INSPECT AND PATCH ANY GAPS TO ENSURE

CONTINUITY OF THE SMOKE PARTITION.

3 PATCH HOLE IN PARTITION WITH 5/8" TYPE 'X' GYPSUM

WALLBOARD EACH SIDE AS NEEDED TO ENSURE

CONTINUITY OF PARTITION.

4 PROVIDE INTERNALLY ILLUMINATED EXIT SIGN WITH

BATTERY BACKUP PER ELECTRICAL DRAWINGS (EXCEPT

WHERE ALREADY EXISTING, VERIFY).

5 REMOVE DOOR AND INFILL WALL. PATCH, TEXTURE,

AND PAINT TO MATCH EXISTING WALL.

SEE DETAIL 2/ A6.01

6 PROVIDE TEMPORARY DUST PROTECTION/PARTITION

DURING WORK AT DOOR 157 TO PROTECT THE

DINING AND KITCHEN FACILITIES. COORDINATE

TIMING AND POSITIONING WITH OWNER.

PLAN LEGEND:

SMOKE BARRIER

1-HOUR FIRE PARTITION FOR CORRIDORS.

20 MINUTE DOORS PER OSSC 716

1-HOUR FIRE BARRIER FOR SHAFTS/STAIRS.

60 MINUTE DOORS PER OSSC 716

GENERAL PLAN NOTES:

1. GENERAL NOTES APPLY TO ALL DRAWINGS.

2. DRAWINGS ARE DIAGRAMMATIC ONLY AND SHOULD

NOT BE SCALED. NOTIFY ARCHITECT OF ANY

DISCREPANCIES IMMEDIATELY UPON DISCOVERY.

OBTAIN CLARIFICATION OF DIMENSIONS OR

DISCREPANCIES PRIOR TO PROCEEDING WITH AREA OF

REQUIRED WORK.

3. DIMENSIONS ARE TO FACE OF FRAMING.

DIMENSIONS STATED AS CLEAR ARE TO FACE OF

FINISH.

4. SEE WALL SECTIONS FOR DESCRIPTION OF EXTERIOR

WALL MATERIALS.

5. ALL INTERIOR PARTITIONS TO RECEIVE GLASS FIBER

INSULATION, FULL HEIGHT.

6. COORDINATE LOCATION OF RECESSED OR SEMI-

RECESSED ITEMS TO AVOID BACK TO BACK

INSTALLATION AND TO REDUCE NOISE TRANSFER

THROUGH PARTITIONS.

7. INSTALL WALL BACKING FOR ALL WALL MOUNTED

ITEMS, INCLUDING BUT NOT LIMITED TO THE

FOLLOWING: DOOR STOPS, FIXTURES, WALL

CABINETS, SHELVING, COUNTERS, TOILET

ACCESSORIES, SECURITY EQUIPMENT, TACK BOARDS

AND MARKER BOARDS, HAND RAILS AND WINDOW

COVERING TRACKS.

8. SEPARATE AREAS IN WHICH WORK IS BEING

CONDUCTED FROM OTHER AREAS THAT ARE STILL

OCCUPIED.

A. PROVIDE, ERECT, AND MAINTAIN TEMPORARY

DUSTPROOF PARTITIONS OF SUITABLE

CONSTRUCTION IN LOCATIONS INDICATED ON

DRAWINGS OR AS DIRECTED.

1. GENERAL NOTES APPLY TO ALL DRAWINGS.

2. DRAWINGS ARE DIAGRAMMATIC ONLY AND SHOULD

NOT BE SCALED. NOTIFY ARCHITECT OF ANY

DISCREPANCIES IMMEDIATELY UPON DISCOVERY.

OBTAIN CLARIFICATION OF DIMENSIONS OR

DISCREPANCIES PRIOR TO PROCEEDING WITH AREA OF

REQUIRED WORK.

3. DIMENSIONS ARE TO FACE OF FRAMING.

DIMENSIONS STATED AS CLEAR ARE TO FACE OF

FINISH.

4. SEE WALL SECTIONS FOR DESCRIPTION OF EXTERIOR

WALL MATERIALS.

5. ALL INTERIOR PARTITIONS TO RECEIVE GLASS FIBER

INSULATION, FULL HEIGHT.

6. COORDINATE LOCATION OF RECESSED OR SEMI-

RECESSED ITEMS TO AVOID BACK TO BACK

INSTALLATION AND TO REDUCE NOISE TRANSFER

THROUGH PARTITIONS.

7. INSTALL WALL BACKING FOR ALL WALL MOUNTED

ITEMS, INCLUDING BUT NOT LIMITED TO THE

FOLLOWING: DOOR STOPS, FIXTURES, WALL

CABINETS, SHELVING, COUNTERS, TOILET

ACCESSORIES, SECURITY EQUIPMENT, TACK BOARDS

AND MARKER BOARDS, HAND RAILS AND WINDOW

COVERING TRACKS.

8. SEPARATE AREAS IN WHICH WORK IS BEING

CONDUCTED FROM OTHER AREAS THAT ARE STILL

OCCUPIED.

A. PROVIDE, ERECT, AND MAINTAIN TEMPORARY

DUSTPROOF PARTITIONS OF SUITABLE

CONSTRUCTION IN LOCATIONS INDICATED ON

DRAWINGS OR AS DIRECTED.

9. PROTECT EXISTING WORK TO REMAIN.

A. PREVENT MOVEMENT OF STRUCTURE; PROVIDE

SHORING AND BRACING IF NECESSARY.

B. PERFORM CUTTING TO ACCOMPLISH REMOVALS

NEATLY AND AS SPECIFIED FOR CUTTING NEW

WORK.

C. REPAIR ADJACENT CONSTRUCTION AND FINISHES

DAMAGED DURING REMOVAL WORK.

D. PATCH AS SPECIFIED FOR PATCHING NEW WORK.

10. REMOVE DEBRIS, JUNK, AND TRASH FROM SITE.

11. REMOVE FROM SITE ALL MATERIALS NOT TO BE REUSED

ON SITE; DO NOT BURN OR BURY.

12. LEAVE SITE IN CLEAN CONDITION, READY FOR

SUBSEQUENT WORK.

13. CLEAN UP SPILLAGE AND WIND-BLOWN DEBRIS FROM

PUBLIC AND PRIVATE LANDS.

14. WORK SHOWN ON THESE DRAWINGS IS TO BE

SUPPLIED, FURNISHED, CONSTRUCTED, INSTALLED ALL

AS PER THE GENERAL CONDITIONS AND THE

SPECIFICATIONS: EXCEPTIONS AS DESCRIBED BY THE

FOLLOWING ABBREVIATIONS:

A. OFCI OWNER FURNISHED - CONTRACTOR

INSTALLED.

B. OFOI OWNER FURNISHED - OWNER INSTALLED.

C. NIC OR N.I.C. NOT IN CONTRACT OR NOT A

PART OF THIS CONTRACT.

15. IMPORTANT NOTE- ALL DOORS SHALL BE SECURED BY

THE END OF EACH WORKDAY.

LOBBY / INTAKE

RECORDS

LOCKERS

LAW LIBRARY

OFFICE

MAINT.VEST.

REST.REST.

LAUNDRY

STAIR

OFFICE

OFFICE OFFICE

OFFICE OFFICE

REST. REST.

CONFERENCE

ROOM

I.T.

STOR.

STAIR

ELECTRICAL

ELECTRICAL

MECHANICAL

ROOM

BREAK

OFFICE

OFFICE

OFFICE

OFFICE

RECEPTION

STAIR

STORAGE

BOILER

KITCHEN

FREEZER

FREEZER

DISHWASH

OFFICE

OUTDOOR COURT

OFFICE OFFICE

OUTDOOR COURT

OUTDOOR COURT

OUTDOOR COURT

HR OFFICE

EVIDENCE

ELEV.

10410

DINING

STAFF

120 119 1

STAIR

Copyright © 2025, STUDIO 3 ARCHITECTURE, INC.

SHEET

PROJECT #

DATE:

REVISIONS:

A1.20

S A

N T

IA

M C

O R R E C

T

IO

N A

L I

N S T

IT

U T

IO

N

F

IR

E

L

IF

E S A

F E T Y C

O R R E C

T

IO

N S F

O R

A U

M S V

IL

L E H

W Y S

E S A

L E M

O

R

05/29/2026

2026-013

LEVEL 00 - FLOOR PLAN

3/32" = 1'-0"

LEVEL 00 N

0' 16' 24' 32'4' 8' 12'

1 1

1 1

1 1

S S

S S

S

S

S S

S S

S

S S

S SS S

1 11 1 1

1 11 1

SLEEPING

ROOM

DAY ROOM

OFFICE OFFICE

SLEEPING

ROOM

SLEEPING

ROOM

LAUNDRY

STAIR

SLEEPING

ROOM

OFFICE

STAFF

BREAK

OFFICE

STAIR

OFFICE

ELEV.

VIDEO

CLOTHING OFFICE

SHOWER SHOWER

RECORDS

BREAK

CONTROL

CONTROL

STAIR

SLEEPING

ROOM

DAY ROOM

OFFICE OFFICE

SLEEPING

ROOM

SLEEPING

ROOM

OFFICE OFFICE

LAUNDRY

STAIR

209 229

REST.

SECURITY

GATE

SECURE

LOBBY

LOBBY

OFFICE

211 235

SLEEPING

ROOM

SLEEPING

ROOM

FLOOR PLAN NOTES:

1 REPLACE COILING COUNTERTOP DOOR WITH NEW

MANUALLY OPERATED COILING DOOR PER

SPECIFICATIONS. DOOR SHALL HAVE FUSIBLE LINK

AND FIRE ALARM CONNECTION.

2 EXISTING GLASS BLOCK WINDOW ASSEMBLY TO

REMAIN. INSPECT AND PATCH ANY GAPS TO ENSURE

CONTINUITY OF THE SMOKE PARTITION.

3 PATCH HOLE IN PARTITION WITH 5/8" TYPE 'X' GYPSUM

WALLBOARD EACH SIDE AS NEEDED TO ENSURE

CONTINUITY OF PARTITION.

4 PROVIDE INTERNALLY ILLUMINATED EXIT SIGN WITH

BATTERY BACKUP PER ELECTRICAL DRAWINGS (EXCEPT

WHERE ALREADY EXISTING, VERIFY).

5 REMOVE DOOR AND INFILL WALL. PATCH, TEXTURE,

AND PAINT TO MATCH EXISTING WALL.

SEE DETAIL 2/ A6.01

6 PROVIDE TEMPORARY DUST PROTECTION/PARTITION

DURING WORK AT DOOR 157 TO PROTECT THE

DINING AND KITCHEN FACILITIES. COORDINATE

TIMING AND POSITIONING WITH OWNER.

PLAN LEGEND:

SMOKE BARRIER

1-HOUR FIRE PARTITION FOR CORRIDORS.

20 MINUTE DOORS PER OSSC 716

1-HOUR FIRE BARRIER FOR SHAFTS/STAIRS.

60 MINUTE DOORS PER OSSC 716

GENERAL PLAN NOTES:

1. GENERAL NOTES APPLY TO ALL DRAWINGS.

2. DRAWINGS ARE DIAGRAMMATIC ONLY AND SHOULD

NOT BE SCALED. NOTIFY ARCHITECT OF ANY

DISCREPANCIES IMMEDIATELY UPON DISCOVERY.

OBTAIN CLARIFICATION OF DIMENSIONS OR

DISCREPANCIES PRIOR TO PROCEEDING WITH AREA OF

REQUIRED WORK.

3. DIMENSIONS ARE TO FACE OF FRAMING.

DIMENSIONS STATED AS CLEAR ARE TO FACE OF

FINISH.

4. SEE WALL SECTIONS FOR DESCRIPTION OF EXTERIOR

WALL MATERIALS.

5. ALL INTERIOR PARTITIONS TO RECEIVE GLASS FIBER

INSULATION, FULL HEIGHT.

6. COORDINATE LOCATION OF RECESSED OR SEMI-

RECESSED ITEMS TO AVOID BACK TO BACK

INSTALLATION AND TO REDUCE NOISE TRANSFER

THROUGH PARTITIONS.

7. INSTALL WALL BACKING FOR ALL WALL MOUNTED

ITEMS, INCLUDING BUT NOT LIMITED TO THE

FOLLOWING: DOOR STOPS, FIXTURES, WALL

CABINETS, SHELVING, COUNTERS, TOILET

ACCESSORIES, SECURITY EQUIPMENT, TACK BOARDS

AND MARKER BOARDS, HAND RAILS AND WINDOW

COVERING TRACKS.

8. SEPARATE AREAS IN WHICH WORK IS BEING

CONDUCTED FROM OTHER AREAS THAT ARE STILL

OCCUPIED.

A. PROVIDE, ERECT, AND MAINTAIN TEMPORARY

DUSTPROOF PARTITIONS OF SUITABLE

CONSTRUCTION IN LOCATIONS INDICATED ON

DRAWINGS OR AS DIRECTED.

1. GENERAL NOTES APPLY TO ALL DRAWINGS.

2. DRAWINGS ARE DIAGRAMMATIC ONLY AND SHOULD

NOT BE SCALED. NOTIFY ARCHITECT OF ANY

DISCREPANCIES IMMEDIATELY UPON DISCOVERY.

OBTAIN CLARIFICATION OF DIMENSIONS OR

DISCREPANCIES PRIOR TO PROCEEDING WITH AREA OF

REQUIRED WORK.

3. DIMENSIONS ARE TO FACE OF FRAMING.

DIMENSIONS STATED AS CLEAR ARE TO FACE OF

FINISH.

4. SEE WALL SECTIONS FOR DESCRIPTION OF EXTERIOR

WALL MATERIALS.

5. ALL INTERIOR PARTITIONS TO RECEIVE GLASS FIBER

INSULATION, FULL HEIGHT.

6. COORDINATE LOCATION OF RECESSED OR SEMI-

RECESSED ITEMS TO AVOID BACK TO BACK

INSTALLATION AND TO REDUCE NOISE TRANSFER

THROUGH PARTITIONS.

7. INSTALL WALL BACKING FOR ALL WALL MOUNTED

ITEMS, INCLUDING BUT NOT LIMITED TO THE

FOLLOWING: DOOR STOPS, FIXTURES, WALL

CABINETS, SHELVING, COUNTERS, TOILET

ACCESSORIES, SECURITY EQUIPMENT, TACK BOARDS

AND MARKER BOARDS, HAND RAILS AND WINDOW

COVERING TRACKS.

8. SEPARATE AREAS IN WHICH WORK IS BEING

CONDUCTED FROM OTHER AREAS THAT ARE STILL

OCCUPIED.

A. PROVIDE, ERECT, AND MAINTAIN TEMPORARY

DUSTPROOF PARTITIONS OF SUITABLE

CONSTRUCTION IN LOCATIONS INDICATED ON

DRAWINGS OR AS DIRECTED.

9. PROTECT EXISTING WORK TO REMAIN.

A. PREVENT MOVEMENT OF STRUCTURE; PROVIDE

SHORING AND BRACING IF NECESSARY.

B. PERFORM CUTTING TO ACCOMPLISH REMOVALS

NEATLY AND AS SPECIFIED FOR CUTTING NEW

WORK.

C. REPAIR ADJACENT CONSTRUCTION AND FINISHES

DAMAGED DURING REMOVAL WORK.

D. PATCH AS SPECIFIED FOR PATCHING NEW WORK.

10. REMOVE DEBRIS, JUNK, AND TRASH FROM SITE.

11. REMOVE FROM SITE ALL MATERIALS NOT TO BE REUSED

ON SITE; DO NOT BURN OR BURY.

12. LEAVE SITE IN CLEAN CONDITION, READY FOR

SUBSEQUENT WORK.

13. CLEAN UP SPILLAGE AND WIND-BLOWN DEBRIS FROM

PUBLIC AND PRIVATE LANDS.

14. WORK SHOWN ON THESE DRAWINGS IS TO BE

SUPPLIED, FURNISHED, CONSTRUCTED, INSTALLED ALL

AS PER THE GENERAL CONDITIONS AND THE

SPECIFICATIONS: EXCEPTIONS AS DESCRIBED BY THE

FOLLOWING ABBREVIATIONS:

A. OFCI OWNER FURNISHED - CONTRACTOR

INSTALLED.

B. OFOI OWNER FURNISHED - OWNER INSTALLED.

C. NIC OR N.I.C. NOT IN CONTRACT OR NOT A

PART OF THIS CONTRACT.

15. IMPORTANT NOTE- ALL DOORS SHALL BE SECURED BY

THE END OF EACH WORKDAY.

Copyright © 2025, STUDIO 3 ARCHITECTURE, INC.

SHEET

PROJECT #

DATE:

REVISIONS:

A1.21

S A

N T

IA

M C

O R R E C

T

IO

N A

L I

N S T

IT

U T

IO

N

F

IR

E

L

IF

E S A

F E T Y C

O R R E C

T

IO

N S F

O R

A U

M S V

IL

L E H

W Y S

E S A

L E M

O

R

05/29/2026

2026-013

LEVEL 01 - FLOOR PLAN

3/32" = 1'-0"

LEVEL 01 N

1 1

1 11

S S

S S

S

S

S S

S S

S

1 1

S

S

S SS S

1 11 1 1

1 11 1

1 1

1 1

LAUNDRY

STAIR

SLEEPING

ROOM

SLEEPING

ROOM

CLASSROOM

OFFICE

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

DAY ROOM DAY ROOM

OFFICEOFFICE CHAPEL

STAIR

ELEV.

JAN.

LIBRARY

MEDICAL

LOBBY

DENTAL SHOWER

SHOWER CLOTHING

LAB

EXAM

EXAM

OFFICE

OFFICE

EXAM

MEDICAL

STAIR

OFFICE

OFFICE OFFICE OFFICE

LAUNDRY

STAIR

5 3

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

FLOOR PLAN NOTES:

1 REPLACE COILING COUNTERTOP DOOR WITH NEW

MANUALLY OPERATED COILING DOOR PER

SPECIFICATIONS. DOOR SHALL HAVE FUSIBLE LINK

AND FIRE ALARM CONNECTION.

2 EXISTING GLASS BLOCK WINDOW ASSEMBLY TO

REMAIN. INSPECT AND PATCH ANY GAPS TO ENSURE

CONTINUITY OF THE SMOKE PARTITION.

3 PATCH HOLE IN PARTITION WITH 5/8" TYPE 'X' GYPSUM

WALLBOARD EACH SIDE AS NEEDED TO ENSURE

CONTINUITY OF PARTITION.

4 PROVIDE INTERNALLY ILLUMINATED EXIT SIGN WITH

BATTERY BACKUP PER ELECTRICAL DRAWINGS (EXCEPT

WHERE ALREADY EXISTING, VERIFY).

5 REMOVE DOOR AND INFILL WALL. PATCH, TEXTURE,

AND PAINT TO MATCH EXISTING WALL.

SEE DETAIL 2/ A6.01

6 PROVIDE TEMPORARY DUST PROTECTION/PARTITION

DURING WORK AT DOOR 157 TO PROTECT THE

DINING AND KITCHEN FACILITIES. COORDINATE

TIMING AND POSITIONING WITH OWNER.

PLAN LEGEND:

SMOKE BARRIER

1-HOUR FIRE PARTITION FOR CORRIDORS.

20 MINUTE DOORS PER OSSC 716

1-HOUR FIRE BARRIER FOR SHAFTS/STAIRS.

60 MINUTE DOORS PER OSSC 716

GENERAL PLAN NOTES:

1. GENERAL NOTES APPLY TO ALL DRAWINGS.

2. DRAWINGS ARE DIAGRAMMATIC ONLY AND SHOULD

NOT BE SCALED. NOTIFY ARCHITECT OF ANY

DISCREPANCIES IMMEDIATELY UPON DISCOVERY.

OBTAIN CLARIFICATION OF DIMENSIONS OR

DISCREPANCIES PRIOR TO PROCEEDING WITH AREA OF

REQUIRED WORK.

3. DIMENSIONS ARE TO FACE OF FRAMING.

DIMENSIONS STATED AS CLEAR ARE TO FACE OF

FINISH.

4. SEE WALL SECTIONS FOR DESCRIPTION OF EXTERIOR

WALL MATERIALS.

5. ALL INTERIOR PARTITIONS TO RECEIVE GLASS FIBER

INSULATION, FULL HEIGHT.

6. COORDINATE LOCATION OF RECESSED OR SEMI-

RECESSED ITEMS TO AVOID BACK TO BACK

INSTALLATION AND TO REDUCE NOISE TRANSFER

THROUGH PARTITIONS.

7. INSTALL WALL BACKING FOR ALL WALL MOUNTED

ITEMS, INCLUDING BUT NOT LIMITED TO THE

FOLLOWING: DOOR STOPS, FIXTURES, WALL

CABINETS, SHELVING, COUNTERS, TOILET

ACCESSORIES, SECURITY EQUIPMENT, TACK BOARDS

AND MARKER BOARDS, HAND RAILS AND WINDOW

COVERING TRACKS.

8. SEPARATE AREAS IN WHICH WORK IS BEING

CONDUCTED FROM OTHER AREAS THAT ARE STILL

OCCUPIED.

A. PROVIDE, ERECT, AND MAINTAIN TEMPORARY

DUSTPROOF PARTITIONS OF SUITABLE

CONSTRUCTION IN LOCATIONS INDICATED ON

DRAWINGS OR AS DIRECTED.

1. GENERAL NOTES APPLY TO ALL DRAWINGS.

2. DRAWINGS ARE DIAGRAMMATIC ONLY AND SHOULD

NOT BE SCALED. NOTIFY ARCHITECT OF ANY

DISCREPANCIES IMMEDIATELY UPON DISCOVERY.

OBTAIN CLARIFICATION OF DIMENSIONS OR

DISCREPANCIES PRIOR TO PROCEEDING WITH AREA OF

REQUIRED WORK.

3. DIMENSIONS ARE TO FACE OF FRAMING.

DIMENSIONS STATED AS CLEAR ARE TO FACE OF

FINISH.

4. SEE WALL SECTIONS FOR DESCRIPTION OF EXTERIOR

WALL MATERIALS.

5. ALL INTERIOR PARTITIONS TO RECEIVE GLASS FIBER

INSULATION, FULL HEIGHT.

6. COORDINATE LOCATION OF RECESSED OR SEMI-

RECESSED ITEMS TO AVOID BACK TO BACK

INSTALLATION AND TO REDUCE NOISE TRANSFER

THROUGH PARTITIONS.

7. INSTALL WALL BACKING FOR ALL WALL MOUNTED

ITEMS, INCLUDING BUT NOT LIMITED TO THE

FOLLOWING: DOOR STOPS, FIXTURES, WALL

CABINETS, SHELVING, COUNTERS, TOILET

ACCESSORIES, SECURITY EQUIPMENT, TACK BOARDS

AND MARKER BOARDS, HAND RAILS AND WINDOW

COVERING TRACKS.

8. SEPARATE AREAS IN WHICH WORK IS BEING

CONDUCTED FROM OTHER AREAS THAT ARE STILL

OCCUPIED.

A. PROVIDE, ERECT, AND MAINTAIN TEMPORARY

DUSTPROOF PARTITIONS OF SUITABLE

CONSTRUCTION IN LOCATIONS INDICATED ON

DRAWINGS OR AS DIRECTED.

9. PROTECT EXISTING WORK TO REMAIN.

A. PREVENT MOVEMENT OF STRUCTURE; PROVIDE

SHORING AND BRACING IF NECESSARY.

B. PERFORM CUTTING TO ACCOMPLISH REMOVALS

NEATLY AND AS SPECIFIED FOR CUTTING NEW

WORK.

C. REPAIR ADJACENT CONSTRUCTION AND FINISHES

DAMAGED DURING REMOVAL WORK.

D. PATCH AS SPECIFIED FOR PATCHING NEW WORK.

10. REMOVE DEBRIS, JUNK, AND TRASH FROM SITE.

11. REMOVE FROM SITE ALL MATERIALS NOT TO BE REUSED

ON SITE; DO NOT BURN OR BURY.

12. LEAVE SITE IN CLEAN CONDITION, READY FOR

SUBSEQUENT WORK.

13. CLEAN UP SPILLAGE AND WIND-BLOWN DEBRIS FROM

PUBLIC AND PRIVATE LANDS.

14. WORK SHOWN ON THESE DRAWINGS IS TO BE

SUPPLIED, FURNISHED, CONSTRUCTED, INSTALLED ALL

AS PER THE GENERAL CONDITIONS AND THE

SPECIFICATIONS: EXCEPTIONS AS DESCRIBED BY THE

FOLLOWING ABBREVIATIONS:

A. OFCI OWNER FURNISHED - CONTRACTOR

INSTALLED.

B. OFOI OWNER FURNISHED - OWNER INSTALLED.

C. NIC OR N.I.C. NOT IN CONTRACT OR NOT A

PART OF THIS CONTRACT.

15. IMPORTANT NOTE- ALL DOORS SHALL BE SECURED BY

THE END OF EACH WORKDAY.

Copyright © 2025, STUDIO 3 ARCHITECTURE, INC.

SHEET

PROJECT #

DATE:

REVISIONS:

A1.22

S A

N T

IA

M C

O R R E C

T

IO

N A

L I

N S T

IT

U T

IO

N

F

IR

E

L

IF

E S A

F E T Y C

O R R E C

T

IO

N S F

O R

A U

M S V

IL

L E H

W Y S

E S A

L E M

O

R

05/29/2026

2026-013

LEVEL 02 - FLOOR PLAN

3/32" = 1'-0"

LEVEL 02 N

ATTIC ACCESS

D-1 D-2

H E

IG

H T P

E R S

C H

E D

U

LE

H E

IG

H T P

E R S

C H

E D

U

LE

6"6"

'-0

PAINT DOOR PER

SCHEDULE

TEMPERED FROSTED

GLASS

PAINT DOOR PER

SCHEDULE

SCHEDULE

WIDTH PER

SCHEDULE

WIDTH PER

D-3

H E

IG

H T P

E R S

C H

E D

U

LE

6" 6"

'-0

TEMPERED FROSTED

GLASS

PAINT DOOR PER

SCHEDULE

SCHEDULE

WIDTH PER

D-4

H E

IG

H T

V E R

IF

Y C

O U

N T E R

S C

H E D

U

LE

H E

IG

H T P

E R

WIDTH PER SCHEDULE

HARDWARE SCHEDULE

HW-03:

• 3 HD HINGES (NRP)

• 1 CLOSER

• 1 STOREROOM LOCKSET

• GASKETING SET

• 1 DOOR SWEEP

HW-02:HW-01:

HW-04:

• 1 CLOSER

• GASKETING SET

• 1 DOOR SWEEP

• ALL OTHER EXISTING TO REMAIN (REUSE IF NEW DOOR)

• REMOVE EXISTING LOCKSET AND/OR DEADBOLT

• 1 STOREROOM LOCKSET

• GASKETING SET

• 1 DOOR SWEEP

• COVER PLATES FOR EXISTING DEADBOLT

• ALL OTHER EXISTING TO REMAIN

• GASKETING SET

• 1 DOOR SWEEP

• ALL OTHER EXISTING TO REMAIN

HW-05:

• REUSE ALL EXISTING HARDWARE

HW-06: HW-07:

• 3 HD HINGES (NRP)

• 1 CLOSER

• 1 STOREROOM LOCKSET

• 1 MAGNETIC HOLD-OPEN

• GASKETING SET

• 1 DOOR SWEEP

HW-08:

• 1 CLOSER (REPLACE EXISTING, WHERE OCCURS)

• 1 MAGNETIC HOLD-OPEN

• GASKETING SET

• 1 DOOR SWEEP

• ALL OTHER EXISTING TO REMAIN (REUSE IF NEW DOOR)

HW-09:

• REMOVE EXISTING HOLD-OPEN

• 1 CLOSER (REPLACE EXISTING, WHERE OCCURS)

• 1 MAGNETIC HOLD-OPEN

• GASKETING SET

• 1 DOOR SWEEP

• ALL OTHER EXISTING TO REMAIN (REUSE IF NEW DOOR)

HW-10:

• 1 CLOSER (REPLACE EXISTING, WHERE OCCURS)

• GASKETING SET

• 1 DOOR SWEEP

• 1 KICK PLATE

• ALL OTHER EXISTING TO REMAIN (REUSE IF NEW DOOR)

• 1 CLOSER (REPLACE EXISTING, WHERE OCCURS)

• 1 PASSAGE LOCKSET

• GASKETING SET

• 1 DOOR SWEEP

• ALL OTHER EXISTING TO REMAIN (REUSE IF NEW DOOR)

HW-00:

• ALL HARDWARE BY DOOR MANUFACTURER

0. NO WORK AT THIS DOOR. SHOWN FOR REFERENCE ONLY.

1. EXISTING DOOR & FRAME TO REMAIN.

2. PROVIDE NEW DOOR IN EXISTING FRAME.

3. PROVIDE NEW DOOR & FRAME.

4. EXISTING FIRE-RATED LABEL ON DOOR/FRAME TO BE MAINTAINED.

5. ENSURE DOOR AND FRAME HAVE LABEL OF MINIMUM FIRE RATING AS INDICATED.

6. DOOR IN SMOKE PARTITION TO HAVE CLOSER & SWEEP/GASKETING PER HARDWARE SCHEDULE IF NOT EXISTING.

7. NEW COILING COUNTERTOP DOOR WITH FUSIBLE LINK FOR USE IN SMOKE PARTITION.

GENERAL NOTES:

REMARKS:

• ALL DOOR SIZES ARE APPROXIMATE AND BASED ON CASUAL FIELD OBSERVATIONS. THE CONTRACTOR SHALL FIELD VERIFY ALL DOORS TO BE REPLACED PRIOR TO ORDERING. THERE SHALL BE NO FIELD CUTTING OF DOORS. THE CONTRACTOR SHALL ALSO VERIFY LOCATION OF HINGES OR OTHER ITEMS FOR WHICH THE DOOR MUST BE FACTORY PREPPED.

• THE CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING THAT ALL DOORS AND FRAMES WITH A REQUIRED FIRE RATED LABEL HAVE THOSE LABELS PRESENT (WITH AT LEAST THE MINUTE RATING SHOWN) AT THE CONCLUSION OF THE PROJECT. THE CONTRACTOR SHALL ALSO HIRE A THIRD PARTY FIRE DOOR INSPECTION AGENCY ACCEPTABLE TO THE STATE FIRE MARSHAL TO PRODUCE A COMPLIANCE REPORT INDICATING ALL REQUIRED FIRE RATED DOORS AND FRAMES MEET THE MINIMUM RATING NOTED IN THIS SCHEDULE. IF ANY DOORS FAIL THIS INSPECTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY CORRECTIONS AND REINSPECTIONS EXCEPT WHERE THE NATURE OF THE FAILURE IS OUTSIDE THE SCOPE OF REPAIRS NOTED IN

THESE DRAWINGS.

• ALL EXISTING INTERIOR DOORS THAT HAVE A HARDWARE GROUP INDICATING THE ADDITION OF GASKETING AND A DOOR SWEEP SHALL BE ADJUSTED SUCH THAT THE DOOR MEETS THE PERIMETER GAP REQUIREMENTS OF NFPA 80 AND NFPA 105.

GASKETING SHALL BE UL-LISTED FOR FILLING EXCESSIVE FIRE DOOR GAPS, WHERE REQUIRED. INDIVIDUAL GASKETING AND/OR DOOR SWEEPS MAY BE OMITTED WHERE IMPRACTICAL TO INSTALL IF THE DOOR AS CURRENTLY CONSTRUCTED MEETS NFPA 80

AND NFPA 105 AND CAN PASS THE THIRD PARTY INSPECTION.

• ALL DEMOLISHED OR REMOVED DOOR HARDWARE SHALL REMAIN THE PROPERTY OF THE OWNER. VERIFY WITH OWNER BEFORE

DISCARDING OF ANY OTHER DEMOLISHED ITEMS.

EXISTING CONCRETE WALL.

EXISTING DOOR FRAME TO REMAIN. REMOVE DOOR.

INFILL OPENING WITH METAL STUDS AS SHOWN, 16" O.C. MAX.

PROVIDE MINIMUM OF ONE LAYER 5/8" TYPE 'X' GYPSUM

WALLBOARD EACH SIDE. ADD ADDITIONAL LAYERS OF GYP

BOARD AS REQUIRED SUCH THAT WALL SURFACE ALIGNS FLUSH

WITH EXISTING WALL.

INFILL PROVIDES MINIMUM 1-HOUR FIRE RESISTANCE

RATING PER OSSC TABLE 721.1(2), ITEM 13-1.1

SKIM OVER DOOR FRAME WITH DRYWALL JOINT

COMPOUND, TEXTURE AND PAINT TO MATCH

EXISTING WALL.

INFILL STUD CAVITY WITH GLASS FIBER OR MINERAL FIBER

BATT INSULATION.

DOOR SCHEDULE

DOOR # LOCATION WIDTH HEIGHT THK. MAT'L FINISH ELEV FRAME LABEL HDWRE. REMARKS

100 OFFICE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

101 OFFICE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

102 OFFICE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

103 RECEPTION 4' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) 20 MIN HW-01 1,4

104 STAIRWELL 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) 60 MIN HW-02 1,4

105 BREAK ROOM 3' - 0" 6' - 8" 1 3/4" HM PAINT D-3 (E) 60 MIN HW-03 2,5

106 OFFICE 4' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) 20 MIN HW-01 1,4

107 HALLWAY 4' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

108 LVL 00 - EAST WING 4' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) 20 MIN (E) 0,4

109 CONFERENCE ROOM 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

111 RESTROOM 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

112 RESTROOM 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

114 RESTROOM 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

115 OFFICE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

116 OFFICE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

117 HALLWAY 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

118 OFFICE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

119 OFFICE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

120 OFFICE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

121 OFFICE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

122 OFFICE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

123 BRIEFING ROOM 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - HW-04 1,6

124 LAUNDRY 7' - 6" 3' - 6" MTL - D-4 MTL - HW-00 7

135 STAIRWELL 3' - 0" 6' - 6" 1 3/4" (E) (E) (E) (E) 60 MIN (E) 0,4

136 STAIRWELL 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

137 LAUNDRY 3' - 8" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

138 RESTROOM 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

139 LOBBY / INTAKE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

140 LAUNDRY 3' - 0" 6' - 8" 1 3/4" (E) (E) (E) (E) - HW-04 1,6

141 VESTIBULE 3' - 0" 6' - 8" 1 3/4" HM PAINT D-1 HM - HW-05 3

142 LOBBY / INTAKE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

143 VESTIBULE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

144 MAINTENANCE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

145 LAW LIBRARY 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

146 OFFICE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

147 RECORDS 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

148 LAW LIBRARY 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

150 LOCKERS 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

151 SERVER ROOM 3' - 4" 7' - 0" 1 3/4" HM PAINT D-3 (E) 20 MIN HW-04 2,5

152 STORAGE 3' - 4" 7' - 0" 1 3/4" HM PAINT D-1 (E) 20 MIN HW-04 2,5

153 STAIRWELL 4' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) 60 MIN HW-06 1,4

154 HR OFFICE 3' - 4" 7' - 0" 1 3/4" HM PAINT D-2 (E) 20 MIN HW-04 2,5

155 EVIDENCE ROOM 3' - 4" 7' - 0" 1 3/4" HM PAINT D-2 (E) 20 MIN HW-04 2,5

157 DINING 4' - 0" 7' - 0" 1 3/4" HM PAINT D-3 (E) 20 MIN HW-07 2,5

158 RESTROOM 3' - 0" 6' - 7" 1 3/4" (E) (E) (E) (E) - HW-04 1,6

159 RESTROOM 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

160 OFFICE 3' - 4" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

161 OFFICE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

164 OFFICE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

166 MECHANICAL 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0,6

167 KITCHEN 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

168 STORAGE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

169 BOILER 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

171 KITCHEN 6' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

172 STORAGE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

173 STAIRWELL 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

175 RESTROOM 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

176 RESTROOM 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

177 STORAGE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

178 DINING 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

180 BREAK ROOM 3' - 6" 7' - 0" 1 3/4" HM PAINT D-3 (E) 20 MIN HW-03 2,5

181 ELECTRICAL 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

182 ELECTRICAL 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

183 FREEZER 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

184 OFFICE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

185 OFFICE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

186 FREEZER 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

3/8" = 1'-0"

DOOR ELEVATIONS

0" 4' 8'1' 2'

Copyright © 2025, STUDIO 3 ARCHITECTURE, INC.

SHEET

PROJECT #

DATE:

REVISIONS:

A6.01

S A

N T

IA

M C

O R R E C

T

IO

N A

L I

N S T

IT

U T

IO

N

F

IR

E

L

IF

E S A

F E T Y C

O R R E C

T

IO

N S F

O R

A U

M S V

IL

L E H

W Y S

E S A

L E M

O

R

05/29/2026

2026-013

SCHEDULES

DOOR SCHEDULE

DOOR # LOCATION WIDTH HEIGHT THK. MAT'L FINISH ELEV FRAME LABEL HDWRE. REMARKS

200 LOBBY 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

201 CONTROL 2' - 6" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

202 BREAK ROOM 2' - 6" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

203 CLOSET 2' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

204 SECURITY GATE 3' - 6" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

205 RESTROOM 2' - 6" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

206 RESTROOM 2' - 6" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

207 SECURE LOBBY 3' - 9" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

208 SECURE LOBBY 4' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) 20 MIN (E) 0,4

209 LVL 01 - EAST WING 4' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) 20 MIN HW-08 1,4

210 CLOTHING 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

211 CLOSET 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

212 STAIRWELL 3' - 6" 7' - 0" 1 3/4" (E) (E) (E) (E) 60 MIN (E) 0,4

213 LAUNDRY 3' - 4" 7' - 0" 1 3/4" (E) (E) (E) (E) - HW-04 1,6

216 BREAK ROOM 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

217 BREAK ROOM 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

218 OFFICE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

219 OFFICE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

220 OFFICE 3' - 0" 7' - 0" 1 3/4" HM PAINT D-3 (E) 20 MIN HW-04 2,5

221 VIDEO 3' - 4" 7' - 0" 1 3/4" HM PAINT D-1 (E) 20 MIN HW-04 2,5

222 STAIRWELL 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) 60 MIN HW-06 1,4

223 STAIRWELL 3' - 6" 7' - 0" 1 3/4" HM PAINT D-3 (E) 60 MIN HW-06 2,5

224 STAIRWELL 4' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - HW-01 1

225 CORRIDOR 4' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - HW-01 1

226 I.T. OFFICE 3' - 4" 7' - 0" 1 3/4" HM PAINT D-2 (E) 20 MIN HW-04 2,5

227 FORM ROOM 3' - 4" 7' - 0" 1 3/4" HM PAINT D-2 (E) 20 MIN HW-04 2,5

229 LVL 01 - WEST WING 4' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) 20 MIN HW-08 1,4

230 OFFICE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

231 OFFICE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

232 OFFICE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

233 LAUNDRY 3' - 4" 7' - 0" 1 3/4" (E) (E) (E) (E) - HW-04 1,6

234 STAIRWELL 3' - 6" 7' - 0" 1 3/4" (E) (E) (E) (E) 60 MIN (E) 0,4

235 CLOSET 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

237 MAIL ROOM 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

238 STAIRWELL 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) 60 MIN (E) 0,4

239 STAIRWELL 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) 60 MIN (E) 0,4

240 RECORDS 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

DOOR SCHEDULE

DOOR # LOCATION WIDTH HEIGHT THK. MAT'L FINISH ELEV FRAME LABEL HDWRE. REMARKS

300 MEDICAL 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

301 EXAM 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

302 OFFICE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

303 OFFICE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

304 OFFICE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

305 EXAM 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

306 EXAM 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

307 LAB 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

308 EXAM 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

309 CLOSET 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

310 RESTROOM 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

311 RESTROOM 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

312 HEALTH SERVICES 4' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) 20 MIN HW-09 1,4

313 LVL 02 - EAST WING 4' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) 20 MIN HW-08 1,4

314 CLOTHING 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

316 STAIRWELL 3' - 6" 7' - 0" 1 3/4" (E) (E) (E) (E) 60 MIN (E) 0,4

317 LAUNDRY ROOM 3' - 4" 7' - 0" 1 3/4" HM PAINT D-3 (E) - HW-10 2,6

318 OFFICE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

319 OFFICE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

320 OFFICE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

321 OFFICE 3' - 4" 7' - 0" 1 3/4" HM PAINT D-3 (E) 20 MIN HW-04 2,5

322 JANITOR 3' - 4" 7' - 0" 1 3/4" HM PAINT D-1 (E) 20 MIN HW-03 2,5

323 STAIRWELL 4' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) 60 MIN HW-06 1,4

324 LIBRARY 3' - 4" 7' - 0" 1 3/4" (E) (E) (E) (E) 20 MIN HW-04 1,4

325 LIBRARY 3' - 4" 7' - 0" 1 3/4" HM PAINT D-3 (E) 20 MIN HW-03 2,5

327 LVL 02 - WEST WING 4' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) 20 MIN HW-08 1,4

329 OFFICE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

330 OFFICE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

331 OFFICE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

332 CLASSROOM 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

333 OFFICE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

334 OFFICE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

335 LAUNDRY ROOM 3' - 4" 7' - 0" 1 3/4" HM PAINT D-3 (E) - HW-10 2,6

336 STAIRWELL 3' - 6" 7' - 0" 1 3/4" HM PAINT D-1 (E) 60 MIN HW-03 2,5

339 DENTAL 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

340 STAIRWELL 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) 60 MIN (E) 0,4

341 STAIRWELL 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

342 CLASSROOM 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

343 OFFICE 3' - 0" 7' - 0" 1 3/4" (E) (E) (E) (E) - (E) 0

400 ATTIC 3' - 0" 7' - 0" 1 3/4" HM PAINT D-1 HM 60 MIN HW-03 3,5

3" = 1'-0"

DOOR INFILL DETAIL

0" 6" 1'-0"1" 2" 4"

LOBBY / INTAKE

RECORDS

LOCKERS

LAW LIBRARY

OFFICE

MAINT.VEST.REST.REST.

LAUNDRY

STAIR

OFFICE

OFFICE OFFICE

OFFICE OFFICE REST. REST.

CONFERENCE

ROOM

I.T.

STOR.

STAIR

ELECTRICAL

ELECTRICAL

MECHANICAL

ROOM

BREAK

OFFICE

OFFICE

OFFICE

OFFICERECEPTION

STAIR

OFFICE

OUTDOOR COURT

OFFICE OFFICE

OUTDOOR COURT

OUTDOOR COURT

OUTDOOR COURT

HR OFFICE

EVIDENCE

ELEV.

10410

DINING

STAFF

120 119 11

6 100

CONTACT: Mark Denyer

SA

N

TI

A

M C

O R R E C

TI

O

N A

L

IN

ST

IT

U

TI

O N

F

IR

E

L

IF

E -S

A F E

TY

C O

R R E C

TI

O

N S F

O R

A U

M S V

IL

LE

H W

Y S

E

S A

LE

M

O

R

04/27/2026 2026-013

Copyright © 2025, STUDIO 3 ARCHITECTURE, INC.

SHEET

PROJECT #

DATE:

REVISIONS:

M2.00

MECH SHEET

CONTACT: Mark Denyer

E2.00

ELEC FLOOR PLAN

AutoCAD SHX Text

SLEEPING

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

DAY ROOM

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

SLEEPING

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

SLEEPING

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

LAUNDRY

AutoCAD SHX Text

STAIR

AutoCAD SHX Text

SLEEPING

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

STAFF

AutoCAD SHX Text

BREAK

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

STAIR

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

ELEV.

AutoCAD SHX Text

VIDEO

AutoCAD SHX Text

CLOTHING

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

SHOWER

AutoCAD SHX Text

SHOWER

AutoCAD SHX Text

RECORDS

AutoCAD SHX Text

BREAK

AutoCAD SHX Text

CONTROL

AutoCAD SHX Text

CONTROL

AutoCAD SHX Text

STAIR

AutoCAD SHX Text

SLEEPING

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

DAY ROOM

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

SLEEPING

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

SLEEPING

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

LAUNDRY

AutoCAD SHX Text

STAIR

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

REST.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SECURITY

AutoCAD SHX Text

GATE

AutoCAD SHX Text

AutoCAD SHX Text

SECURE

AutoCAD SHX Text

LOBBY

AutoCAD SHX Text

LOBBY

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SLEEPING

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

SLEEPING

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

LOBBY / INTAKE

AutoCAD SHX Text

RECORDS

AutoCAD SHX Text

LOCKERS

AutoCAD SHX Text

LAW LIBRARY

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

MAINT.

AutoCAD SHX Text

VEST.

AutoCAD SHX Text

REST.

AutoCAD SHX Text

REST.

AutoCAD SHX Text

LAUNDRY

AutoCAD SHX Text

STAIR

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

REST.

AutoCAD SHX Text

REST.

AutoCAD SHX Text

CONFERENCE

AutoCAD SHX Text

ROOM

AutoCAD SHX Text I.T.

AutoCAD SHX Text

STOR.

AutoCAD SHX Text

STAIR

AutoCAD SHX Text

ELECTRICAL

AutoCAD SHX Text

ELECTRICAL

AutoCAD SHX Text

MECHANICAL

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

BREAK

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

RECEPTION

AutoCAD SHX Text

STAIR

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text

BOILER

AutoCAD SHX Text

KITCHEN

AutoCAD SHX Text

FREEZER

AutoCAD SHX Text

FREEZER

AutoCAD SHX Text

DISHWASH

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OUTDOOR COURT

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OUTDOOR COURT

AutoCAD SHX Text

OUTDOOR COURT

AutoCAD SHX Text

OUTDOOR COURT

AutoCAD SHX Text

HR OFFICE

AutoCAD SHX Text

EVIDENCE

AutoCAD SHX Text

ELEV.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DINING

AutoCAD SHX Text

STAFF

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: 3/32''=1'-0''

AutoCAD SHX Text

ELECTRICAL FLOOR PLAN-BASEMENT

AutoCAD SHX Text E2.00

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

PLAN NOTES:

AutoCAD SHX Text

1. PROVIDE EXIT SIGN, AND CONNECT TO LIFE-SAFETY BRANCH CIRCUIT ON GENERATOR POWER. IF LIFE-SAFETY BRANCH PROVIDE EXIT SIGN, AND CONNECT TO LIFE-SAFETY BRANCH CIRCUIT ON GENERATOR POWER. IF LIFE-SAFETY BRANCH CIRCUIT IS NOT AVAILABLE, PROVIDE EXIT SIGN WITH BATTERY BACKUP AND CONNECTED TO UNSWITCHED LOCAL LIGHTING BRANCH CIRCUIT. 2. CONNECT MAGNETIC HOLD TO FIRE ALARM TO RELEASE DURING ALARM CONDITION. CONNECT MAGNETIC HOLD TO FIRE ALARM TO RELEASE DURING ALARM CONDITION. 3. PROVIDE AND INSTALL DUCT DETECTOR AND CONNECT TO FIRE ALARM PANEL. VERIFY EXACT PROVIDE AND INSTALL DUCT DETECTOR AND CONNECT TO FIRE ALARM PANEL. VERIFY EXACT LOCATION OF DUCT WORK WITH MECHANICAL PLANS. 4. NOT USED. NOT USED. 5. EXISTING FIRE ALARM CONTROL PANEL.EXISTING FIRE ALARM CONTROL PANEL.

AutoCAD SHX Text P

AutoCAD SHX Text

FACP

AutoCAD SHX Text (E)

AutoCAD SHX Text

AutoCAD SHX Text M

AutoCAD SHX Text

AutoCAD SHX Text M

AutoCAD SHX Text

AutoCAD SHX Text M

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: 3/32''=1'-0''

AutoCAD SHX Text

ELECTRICAL FLOOR PLAN-LEVEL 1

AutoCAD SHX Text E2.00

AutoCAD SHX Text

AutoCAD SHX Text

GENERAL NOTES:

AutoCAD SHX Text

1. ALL WIRING IN EXPOSED LOCATIONS TO BE RUN IN CONDUIT. EMT IS ACCEPTABLE.ALL WIRING IN EXPOSED LOCATIONS TO BE RUN IN CONDUIT. EMT IS ACCEPTABLE.

AutoCAD SHX Text

WWW.MFIA-ENG.COM

AutoCAD SHX Text

FAX: (503) 234-0677

AutoCAD SHX Text

PHN: (503) 234-0548

AutoCAD SHX Text I

AutoCAD SHX Text N

AutoCAD SHX Text

AutoCAD SHX Text Consulting Engineers

AutoCAD SHX Text 2007 S.E. Ash St.

AutoCAD SHX Text Portland, OR 97214

AutoCAD SHX Text C

AutoCAD SHX Text A

AutoCAD SHX Text I

AutoCAD SHX Text F

AutoCAD SHX Text M

AutoCAD SHX Text

SANTIAM CORRECTIONAL INSTITUTION

AutoCAD SHX Text

FIRE & LIFE-SAFETY CORRECTIONS FOR:

AutoCAD SHX Text

4005 AUMSVILLE HWY SE, SALEM, OR 97317

AutoCAD SHX Text 04/27/2026

AutoCAD SHX Text 2026-013

AutoCAD SHX Text Copyright © 2025, STUDIO 3 ARCHITECTURE, INC.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

PROJECT #

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

REVISIONS:

CONTACT: Mark Denyer

E2.01

ELEC FLOOR PLAN

LEVEL 3

AutoCAD SHX Text

SCALE: 3/32''=1'-0''

AutoCAD SHX Text

ELECTRICAL FLOOR PLAN-LEVEL 3

AutoCAD SHX Text E2.01

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

PLAN NOTES:

AutoCAD SHX Text

1. NOT USED. NOT USED. 2. CONNECT MAGNETIC HOLD TO FIRE ALARM TO RELEASE DURING ALARM CONDITION.CONNECT MAGNETIC HOLD TO FIRE ALARM TO RELEASE DURING ALARM CONDITION.

AutoCAD SHX Text M

AutoCAD SHX Text

AutoCAD SHX Text M

AutoCAD SHX Text

AutoCAD SHX Text M

AutoCAD SHX Text

AutoCAD SHX Text

LAUNDRY

AutoCAD SHX Text

STAIR

AutoCAD SHX Text

SLEEPING

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

SLEEPING

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

CLASSROOM

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

SLEEPING

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

SLEEPING

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

SLEEPING

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

DAY ROOM

AutoCAD SHX Text

DAY ROOM

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

CHAPEL

AutoCAD SHX Text

STAIR

AutoCAD SHX Text

ELEV.

AutoCAD SHX Text

JAN.

AutoCAD SHX Text

LIBRARY

AutoCAD SHX Text

MEDICAL

AutoCAD SHX Text

LOBBY

AutoCAD SHX Text

DENTAL

AutoCAD SHX Text

SHOWER

AutoCAD SHX Text

SHOWER

AutoCAD SHX Text

CLOTHING

AutoCAD SHX Text

LAB

AutoCAD SHX Text

EXAM

AutoCAD SHX Text

EXAM

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

EXAM

AutoCAD SHX Text

MEDICAL

AutoCAD SHX Text

STAIR

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

LAUNDRY

AutoCAD SHX Text

STAIR

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SLEEPING

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

SLEEPING

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

SLEEPING

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

GENERAL NOTES:

AutoCAD SHX Text

1. ALL WIRING IN EXPOSED LOCATIONS TO BE RUN IN CONDUIT. EMT IS ACCEPTABLE.ALL WIRING IN EXPOSED LOCATIONS TO BE RUN IN CONDUIT. EMT IS ACCEPTABLE.

AutoCAD SHX Text

WWW.MFIA-ENG.COM

AutoCAD SHX Text

FAX: (503) 234-0677

AutoCAD SHX Text

PHN: (503) 234-0548

AutoCAD SHX Text I

AutoCAD SHX Text N

AutoCAD SHX Text

AutoCAD SHX Text Consulting Engineers

AutoCAD SHX Text 2007 S.E. Ash St.

AutoCAD SHX Text Portland, OR 97214

AutoCAD SHX Text C

AutoCAD SHX Text A

AutoCAD SHX Text I

AutoCAD SHX Text F

AutoCAD SHX Text M

AutoCAD SHX Text

SANTIAM CORRECTIONAL INSTITUTION

AutoCAD SHX Text

FIRE & LIFE-SAFETY CORRECTIONS FOR:

AutoCAD SHX Text

4005 AUMSVILLE HWY SE, SALEM, OR 97317

AutoCAD SHX Text 04/27/2026

AutoCAD SHX Text 2026-013

AutoCAD SHX Text Copyright © 2025, STUDIO 3 ARCHITECTURE, INC.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

PROJECT #

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

REVISIONS:

Sheets
A1.01 - SITE PLAN
A1.20 - LEVEL 00 - FLOOR PLAN
A1.21 - LEVEL 01 - FLOOR PLAN
A1.22 - LEVEL 02 - FLOOR PLAN
A6.01 - SCHEDULES
G0.01 - COVER SHEET

File details come from the government source that posted it. Updated .