J-9_Gadsden_Facility_Report_2014_00425_Final_Vol2_Part1.pdf
PDF 10 MB Posted
- Attached to
- GADSDEN JCC W/ OA CTS
- Solicitation number
- 1630J3-18-R-00003
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Gadsden_RFP_Q&As.docx | DOCX document | |
| Gadsden_RFP_Revised_Section_B.docx | DOCX document | |
| J-4_Staffing_Chart.docx | DOCX document | |
| 1630J3-18-R-00003-0003_-_Gadsden_RFP.pdf | ||
| Gadsden_Amendment_0002_Sol_1630J3-18-R-00003.pdf | ||
| Sol_1630J3-18-R-00003_Amd_0001_Gadsden.pdf | ||
| Sol_1630J3-18-R-00003.pdf | ||
| J-4_Staffing_Chart.docx | DOCX document | |
| J-1_Cost_Detail_Template.docx | DOCX document | |
| J-7_Past_Performance_Questionnaire.docx | DOCX document | |
| J-9_Gadsden_Facility_Report_2014_00425_Final_Vol1_Part1.pdf | ||
| J-5_Career_Technical_Skills_Training.pdf | ||
| J-10_MasterPropertyRpt[1].pdf | ||
| J-8_Standard_Form_1413_-_Statement_and_Acknowledgement.docx | DOCX document | |
| J-11_Inventory_of_Estimate_of_Expendables_2018.pdf | ||
| J-6_Subcontracting_Plan_Summary_Sheet.docx | DOCX document | |
| J-3_Financial_Display_By_Year.docx | DOCX document | |
| J-12_Gadsden_Utilities_2018.pdf | ||
| J-2_Statement_of_Financial_Cabability.docx | DOCX document |
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GADSDEN
Job Corps Center Gadsden, AL
Facility Planning Report Volume II
Supporting Data
Final January 2015
Department of Labor/ Office of Job Corps
GADSDEN
Job Corps Center Gadsden, AL
Facility Planning Report Volume II
Supporting Data
Final January 2015
View of Buildings 6 and 9
VOLUME I - PLANNING STRATEGY
Acronyms and Abbreviations Defi nition of Terms Executive Summary Existing Site Plan Center Statistics Facility Survey Assessment Results and Recommendations
1.0 INTRODUCTION
• Objective and Scope
• Report Contents
2.0 EXISTING CONDITIONS
• Background
• Ownership
• General Site Conditions
• General Building Conditions
• Preventive Maintenance
• Facility Assessment by Function
• Environmental Management
• Resource Use/Conservation
• Sustainability
• Accessibility Standards
• Completed and Current Projects
• Health and Life Safety Issues
• Defi ciency Summary
3.0 PLANNING ANALYSIS
• Space Utilization Analysis
• Federal Real Property Asset Management
• Defi ciency Analysis
• Facility Condition Summary
• Building Condition by Function
• Planning Analysis Results and Conclusions
4.0 RECOMMENDATIONS
• Status of Previous Plan
• Proposed Plan
• Funded Not Corrected (FNC) Defi ciencies
• Summary of Proposed Plan
• Proposed Site Plan
• Implementation Plan
• Summary List of National Projects
• Project Data Sheets
VOLUME II - SUPPORTING DATA
Acronyms and Abbreviations Defi nition of Terms Executive Summary
1.0 SITE LAYOUT AND PLANS
• Location Map
• Exisiting Site Plan
2.0 DESCRIPTIONS
• Buildings and Structures
• Space Utilization By Function
• NSF by Building
• Environmental Management Report
• Radon Report
• Site Descriptions
• Building Descriptions
3.0 DEFICIENCIES
APPENDICES - CORRESPONDENCE AND REPORTS
Appendix A.
• Center Review Meeting Minutes
• Survey Brief
• Student Questionnaire
Appendix B.
• Life Safety Defi ciencies and List
Appendix C.
• O&M Defi ciencies List
Appendix D.
• Active Warranty List
Appendix E.
• FRPC Performance Measures Matrix
Acronyms and Abbreviations
ACRONYMS AND ABBREVIATIONS
A Amperage ABAAS Architectural Barriers Act Accessibility Standard ACM Asbestos-Containing Materials AFUE Annual Fuel Utilization Efficiency AHU Air Handling Unit ANSI American National Standards Institute ARRA American Recovery and Reinvestment Act of 2009 BTU British Thermal Units\ CAA Clean Air Act CCF Hundred Cubic Feet CCTV Closed Circuit Television CDC Child Development Center CDC Centers for Disease Control and Prevention CDP Career Development Period CDSS Career Development Service System CFL Compact Fluorescent Light Bulbs CFM Cubic Feet per Minute CIS Center Information System CMA Certified Medical Assistant CMMS Computerized Maintenance Management System CMU Concrete Masonry Unit CAN Certified Nursing Assistant CO Carbon Monoxide CO Contracting Officer COR Contracting Officer’s Representative CPP Career Preparation Period CRA Construction, Rehabilitation, and Acquisition CTP Career Transition Period CTS Career Transition Services
CTST Career Technical Skills Training (formerly Vocational Skills Training [VST])
CW Cold Water CWA Clean Water Act DDC Direct Digital Controls DFAM Division of Facilities and Asset Management DOL Department of Labor EISA Energy Independence and Security Act of 2007 EMT Emergency Medical Technician
EMT Electrical Metal Tubing (Conduit) EO Executive Order EPA U.S. Environmental Protection Agency EPCRA Emergency Planning and Community Right-to-Know Act (1986) EPMD Ethylene Propylene Diene Terpolymer ESC Engineering Support Contractor ESCIS Engineering Support Contractor Information System ESL English as a Second Language oF Degrees Fahrenheit FACP Fire Alarm Control/Annunciator Panel fc Foot Candle FNC Funded Not Corrected FOP Financial Operating Plan FRPC Federal Real Property Council FY Fiscal Year GAO General Accounting Office GED General Educational Development GFCI Ground Fault Circuit Interrupter gph Gallons per Hour GSA General Services Administration GSF Gross Square Feet HID High Intensity Discharge HP Horsepower HSD High School Diploma HTW Hazard and Toxic Waste HVAC Heating, Ventilating, and Air Conditioning HW Hot Water IBC International Building Code IMC International Mechanical Code ION Inventory of Needs IPC International Plumbing code KBTU Thousand British Thermal Unit/Gross Square Foot/Year kV Kilovolt kVA Kilovolt-Amps kw Kilowatt JCC Job Corps Center JCDC Job Corps Data Center JCH Job Corps Handbook kWh Kilowatt Hours LAN Local Area Network LED Light Emitting Diode LF Linear Feet MBH Thousand BTUs per Hour MBTU Thousand British Thermal Unit MWH Megawatt Hour MC Mission Critical MCF Million Cubic Feet MDNC Mission Dependent, Not Critical MDP Main Distribution Panel MLO Main Lug Only m/s Meters/Second MTS Manual Transfer Switch NEC National Electric Code NEMA National Electrical Manufacturers Association NEPA National Environmental Protection Act NFPA National Fire Protection Association NMD Not Mission Dependent NSF Net Square Feet OA Outreach and Admissions OBS On Board Strength OCM Office of Contract Management OIG Office of Inspector General O&M Operations and Maintenance OSHA Occupational Safety and Health Administration PA Public Address pCi Picocurie PV Photovoltaic PVC Polyvinyl Chloride RCRA Resource Conservation and Recovery Act RTU Rooftop Unit SGA Student Government Association SHPO State Historic Preservation Office SF Square Feet SPCC Spill Prevention, Control and Countermeasure SST Social Skills Training T5 Fluorescent Lighting Designation (High Efficiency)
T8 Fluorescent Lighting Designation T12 Fluorescent Lighting Designation (Low Efficiency TSCA Toxic Substances Control Act of 1976 TV Television TVSS Transient Voltage Surge Suppression UEV Unevaluated UFAS Uniform Federal Accessibility Standards UL Underwriters Laboratories USDA U. S. Department of Agriculture V Volt VCR Video Cassette Recorder VST Vocational Skills Training W Watt WAN Wide Area Network WBL Work-Based Learning WIA Workforce Investment Act WIB Workforce Investment Board
Defi nition of Terms
DEFINITION OF TERMS
Accessibility: The degree to which a product, device, service, or environment is available to as many people as possible. Accessibility can be viewed as the "ability to access" and benefit from some system or entity. The Federal Government is required to comply with published law (Architectural Barriers Act (ABA) of 1968 , American Disabilities Act of 1990), regulations and related standards. Accessibility laws and standards have evolved over the past 12 years. DOL now follows ABA Accessibility Standards for Federal Facilities (ABAAS) adopted by the General Services Administration.
Annual Operating Cost: This FRPC performance measure reflects the cost to operate each used asset and consists of lease costs as well as costs related to recurring maintenance, utilities, janitorial, and roads and grounds expenses (Source: FRPC 2012).
Building: In accordance with the FRPC 2012 Guidance for Real Property Inventory Reporting, a building includes an enclosure for human occupancy that serves a variety of functions (food service, education, recreation, medical/dental, storage, administration) and is likely to have full utility services (heating, cooling, etc.). A building typically is over 400 square feet.
Building Condition Rating by Function: Each building is assigned a building condition based on the physical condition of the building and the impact on the functional use of the facility. Three ratings are possible:
Good: The facility condition is not impacting the facility function. A facility can have deficiencies and still be considered good.
Fair: The facility condition is impacting the facility function and deficiencies are limited to less than 30% of the replacement value. Correction of the deficiencies would allow the facility to return to a good status.
Poor: The facility condition is significantly impacting the facility function and/or deficiencies are more than 30% of the replacement value. Generally a poor rating indicates a “gut renovation or total replacement/demolition would be required.
Building/Structure Ratings: Each building is rated according to three ratings (good, fair, and poor) based on evaluations of the structure, exterior, interior, mechanical, and electrical elements. Three ratings are possible:
Good: The facility condition is not impacting the facility function. A facility can have deficiencies and still be considered good.
Fair: The facility condition is impacting the facility function and deficiencies are limited to less than 30% of the replacement value. Correction of the deficiencies would allow the facility to return to a good status.
Poor: The facility condition is significantly impacting the facility function and/or deficiencies are more than 30% of the replacement value. Generally a poor rating indicates a “gut renovation or total replacement/demolition would be required
Construction Type: The International Building Code (IBC) construction classifications include the following:
Type I and II. Those types of construction in which building elements are of noncombustible materials, except as permitted in Section 603 and elsewhere in the code.
Type II and III. Any type of construction where the exterior walls are of noncombustible material and the interior building elements are of any material permitted by the code.
Type IV. This type (heavy timber, HT) is where the exterior walls are of noncombustible material and the interior building elements are of solid or laminated wood without concealed spaces.
Type V. That type of construction where structural elements, exterior walls, and interior walls are of any materials permitted by the code.
Contract Strength: The authorized number of students at a Center in accordance with the contract between the Region and Center Operator.
Deficiency: A deficiency at a Center represents the spectrum of conditions related to the Center’s mission and/or its physical, functional, or operational features do not meet related goals, standards, codes, or other measures of acceptability. Each deficiency at a JCC or CCC initially is categorized as one of the following three deficiencies: Program, Site, or Building:
Program: Program deficiencies address issues such as square footage shortages or the omission of amenities required or standard for the proper operation of a particular Job Corps function.
Site: Site deficiencies indicate adverse site and infrastructure conditions which negatively impact operations and environment (e.g., site lighting, sidewalks, roads, etc.)
Building: Building deficiencies indicate adverse conditions at the building level.
This element includes the substructure, shell, interior, services (plumbing, HVAC, fire protection, and electrical), and equipment and furnishings.
Deficiency Classifications (I to IV): Deficiency classifications are defined as follows:
Class IA - Deficiencies which address imminent life safety and health hazards.
Class II - Deficiencies which address code violations, however, do not represent imminent life safety and health hazards.
A - Deficiencies which violate code (Federal, State or Local) and may result in an interruption of center operations if not corrected.
B - Deficiencies which violate code (Federal, State or Local) and have no immediate impact on center operations if not corrected.
C- Deficiencies which are not in compliance for accessibility in accordance with the Architectural Barriers Act (ABA), Americans with Disabilities Act (ADA), Uniform Federal Accessibility Standards (UFAS), or other applicable standards.
Class III - Deficiencies which address facility repair, replacement or maintenance.
A - Deficiencies which if not corrected may result in an interruption of center operations.
B - Deficiencies which if not corrected will have minimal impact on center operations or can be mitigated through temporary measures until the deficiency is corrected.
Class IV – Deficiencies which address programmatic needs.
A - Deficiencies which if corrected produce substantial improvements in the quality of the learning and living environment.
B - Deficiencies which if corrected are desirable enhancements.
Deficiency Funding Status: The status of the deficiency included the following categories:
Funded deficiencies report indicates the funding year for funded Regional projects, which have dollar amounts shown, or deficiencies assigned to funded National and Regional projects without dollar amounts. Major Regional projects are equivalent to National projects but assigned to the Federal agency (e.g., U.S.
Department of Agriculture) that acts as the Center operator. All operations and maintenance (O&M) deficiencies are treated as funded through the Center Operators O&M contract within the Region.
Proposed deficiencies have been assigned to a proposed future National project.
Unfunded deficiencies are Regional projects unless or until they are assigned to a National project.
Deficiency Status: The deficiency status is tracked and updated during the three-year facility survey cycle, or as such deficiencies are corrected and reported. The status includes:
Uncorrected: Once a deficiency is identified, documented, reported, and assigned for correction, the deficiency remains uncorrected until such time that the deficiency is corrected, reported, and verified.
Corrected: A corrected deficiency is one that has been assigned, funded, corrected, reported, and verified. Typically, the ESC verifies completion of the deficiency through the facility survey or site visit. The Center also may report completion and provide verifiable evidence of the correction, subject to review by the ESC.
Funded Not Corrected: A deficiency that has been approved and authorized as a regional project through the CRA budget, emergency or supplemental funding, or the Life Safety Memo. Note: the funding may not have reached the Center yet as the first steps are a FOP allocation by the National Office and a contract modification by the Region.
No Longer Needed: A no longer needed deficiency is one that has been approved and funded as a Regional project, but due to subsequent circumstances, has been reported by the Center as no longer being required to be accomplished. This type of deficiency is verified and confirmed by the ESC and removed from the Funded Not Corrected deficiency category. The Center should take action with its Region to return the funds.
Facility Condition Index: This performance measure reflects the condition of each asset by comparing the current repair needs to the replacement value of the asset. The index is expressed as a percentage, with 100% being a facility with no repair needs.
Gross Square Foot: The sum of all areas on all floors of a building included within the outside faces of its exterior walls, including all vertical penetration areas, for circulation and shaft areas that connect one floor to another. Gross Area is computed by physically measuring or scaling measurements from the outside faces of exterior walls, disregarding cornices, pilasters, buttresses, etc., that extend beyond the wall faces. Exclude areas having less than a 3-foot clear ceiling height unless the criteria of a separate structure are met. Measured in terms of Gross Square Feet (GSF): GSF = Net Usable Area + Structural Space (Source: http://nces.ed.gov/pubs2006/ficm/).
Mission Dependency: The value an asset brings to the performance of the mission as determined by the governing agency. Specific elements of this category include (FRPC 2012):
Mission Critical - – Without constructed asset or parcel of land, mission is compromised.
Mission Dependent, Not critical (MDNC) - Does not fit into Mission Critical or Not Mission Dependent categories.
Not Mission Dependent (NMD) – Mission unaffected
Ownership (Owned vs Leased): If the property is owned, the Federal Government has fee simple interest for the real property asset. If the property is leased, the rights to use the asset are assigned to the Federal Government by a private entity or a non-Federal Government entity for a defined period of time in return for rental payments (FRPC 2012).
National Project: Generally large and complex projects that require professionally prepared drawings and specifications that are time phased (design and construction) and contracted by the DOL National Office.
Net Square Foot: The sum of all areas on all floors of a building assigned to, or available for assignment to, an occupant or specific use. This value is computed by physically measuring or scaling measurements from the inside faces of surfaces that form the boundaries of the designated areas. Exclude areas having less than a 3-foot clear ceiling height unless the criteria of a separate structure are met. Included should be major space use categories for assignable space (e.g., dormitories, education, recreation, etc.) that are used to accomplish the institution’s mission. Net Square foot: NASF = Sum of Areas Designated by the Major Space Use Categories (Source: http://nces.ed.gov/pubs2006/ficm/).
On Board Strength (OBS): The actual number of students on Center on a day to day basis.
Preventive Maintenance: The care and servicing by personnel for the purpose of maintaining equipment and facilities in satisfactory operating condition by providing for systematic inspection, detection, and correction of incipient failures either before they occur or before they develop into major defects (Source: Dictionary of Military and Associated Terms, US DOD 2005).
Property Type: Indicates the asset as one of the following categories of real property:
land, building, structure.
Property Use: Since the elements defined by the FRPC do not match the space use codes employed in ESCIS, a mapping procedure will be created to align the definitions.
In the report, the Federal Real Property Council (FRPC) classifications will be printed for display. The information is available through the property registration field of Engineering Support Contractor Information System (ESCIS), and the current ESCIS designations will be correlated to the FRPC designations as follows:
ESCIS FRPC
Dormitory Dormitories/Barracks Food Service Other Institutional Uses Education School Recreation Other Institutional Uses Medical/Dental Other Institutional Uses Storage Warehouse Administration Office Structure * Storage, Service, Utility
Systems, or Other Land Institutional
* Each structure will be entered manually from the ESCIS database into one of four FRPC categories listed opposite the term “structure”.
Replacement Value: The cost of replacing the existing constructed asset at today’s building standards. It is the amount required to construct an asset of similar size and in the same location at today’s construction standards. The replacement value reported must be greater than zero (FRPC 2012).
Regional Office Project: Generally smaller projects where the funds will be transferred to the region for center execution.
Structure: In accordance with the FRPC 2012 Guidance for Real Property Inventory Reporting, a structure serves to provide storage, service, utility systems and is not likely to have full utilities (heating, cooling, etc.). A structure typically is less than 400 square feet.
Sustainability: Formally known as the World Commission on Environment and Development, the Brundtland Commission's mission in the 1980s was to unite countries to pursue sustainable development. The Commission defined sustainability as the “development which meets the needs of current generations without compromising the ability of future generations to meet their own needs".
Sustainability also is defined as the creation or enhancement of environmental, economic, and social-cultural balance, as realized through business activities, individual actions, and community engagement. Sustainability addresses approaches, methods and practices that optimize the use of energy, water, and materials while reducing greenhouse gas emissions.”
Utilization: This performance measure assesses the degree to which each asset is utilized and is expressed as a percentage. It is calculated on a square footage basis, comparing the square footage used to the “design square footage” based on contract strength (Source: FRPC 2012).
Executive Summary
The facility survey for the Gadsden JCC was completed August 18 to August 22, 2014.
The information presented in Volume II, Supporting Data, represents the current status of the campus.
The information includes the following:
Existing site layout Overall status of existing building and structures Space utilization by building and function compared to recommended standards Status of environmental elements of the Center’s operations Details on the site and buildings and structures based on architectural, electrical, and mechanical survey and supporting documentation Presentation of the status of historical deficiencies and compilation of deficiencies documented through this survey Supporting documentation, as presented in the appendices of the center review meeting; survey brief and student questionnaire; life safety IA/IIA transmittal;
active warranties; and Federal Real Property Council (FRPC) Measures Matrix
Section 1.0 of this volume addresses site layout and plans while Section 2.0 presents details on the buildings and structures. Section 3.0 presents historic deficiencies and their status as well as new ones identified in this survey. The appendices provide additional information as noted below:
Appendix A. Survey Brief Questionnaire Appendix B. Life Safety Deficiencies and List Appendix C. O&M Deficiencies List Appendix D. Active Warranty Report Appendix E. FRPC Performance Measures Matrix
EXECUTIVE SUMMARY
1.0 - Site Layout and Plans
GADSDEN
JOB CORPS CENTER
GADSDEN, ALABAMA
GADSDEN JCC
10 MI5 0
2.0 - Descriptions
2.0 DESCRIPTIONS
In this section, the following information on the Center and its buildings and structures is presented in tabular format:
Building and Structures – This table indicates the building type, asset number, name, use group, gross square footage (GSF), construction year, number of floors, number of sleeping room and number of beds, construction type (noted as numerical values instead of code-specified Roman numerals), status (active or closed), and overall condition. The possible International Building Code (IBC) construction classifications include the following:
Type I and II. Those types of construction in which building elements are of noncombustible materials, except as permitted in Section 603 and elsewhere in the code.
Type III. This type of construction is where the exterior walls are of noncombustible material and the interior building elements are of any material permitted by the code.
Type IV. This type (heavy timber, HT) is where the exterior walls are of noncombustible material and the interior building elements are of solid or laminated wood without concealed spaces. Fire-retardant-treated wood framing complying with IBC section 2303.2 shall be permitted within exterior wall construction with a 2-hour rating or less.
Type V. That type of construction where structural elements, exterior walls, and interior walls are of any materials permitted by the code.
The overall building/structure condition is rated in one of three categories: good, fair, or poor.
Space Utilization by Function - This table compares the DOL recommended net square footage per enrollee and for the total function (e.g., housing, education, food service, recreation, medical/dental, administration, storage/support) to the actual values.
Net Square Footage by Building - This table compares the DOL recommended net square footage for the buildings with the function (e.g., housing, education, food service, recreation, medical/dental, storage/support) to the actual values and presents a percentage difference in the two values. In some instances, a recommended value is not available for sub-elements of a function; therefore, the recommended value is shown as “0”.
Environmental Management Report – This table summarizes regulatory related solid and hazardous waste information in accordance with the Resource Conservation and Recovery Act (RCRA) and the presence or absence of hazardous material storage facilities in accordance with Emergency Planning and Community Right-to-Know Act of
1986 (EPCRA). An inventory of petroleum storage tanks is noted as well as asbestos and polychlorinated biphenyls (PCBs) in accordance with the Clean Water Act (CWA) and Toxic Substance Control Act (TSCA), respectively. In addition, this report statuses air quality as required under the Clean Air Act (CAA).Any radon testing of buildings also is documented.
Site Descriptions – Tabular information is documented for the site. Among the data presented are the topography; total number of buildings and structures; roads, parking and sidewalks; fencing; site utilities; storage tanks; accessibility; historic preservation;
natural hazards; and sustainability. The overall condition of the site is rated in one of three categories: good, fair, or poor.
Building Descriptions – Tabular information, as well as photographs and floor plan drawings, are provided for each building or structure, as appropriate, in the following categories: real estate; accessibility; building envelope; interior finishes; vertical circulation; heating, ventilation and air conditioning (HVAC); plumbing; fire protection;
electrical services; fire alarms; carbon monoxide detection; communication; and building metering. The overall condition of the building and its five key subsystems (structure, exterior, interior, mechanical, and electrical) are rated in one of three categories: good, fair, or poor. If applicable, recommendations for renovation or demolition are provided.
BUILDINGS AND STRUCTURES
00425 GADSDEN 01/26/2015
1Page: of Date:
0001 - ADMIN/EDUCATION/WELLNESS
0002 - COUNSELOR
0003 - MALE DORMITORY
0004 - FEMALE DORMITORY
0005 - DRIVER'S EDUCATION
0006 - EDUCATION
0009 - CAFETERIA/CULINARY ARTS
0010 - GUARD HOUSE
0011 - VACANT
0013 - ACADEMIC
0014 - PHYSICAL FITNESS CENTER
0006A - COVERED WALKWAY (12 Ft x 46 Ft) 0009A - COVERED WALKWAY (12 Ft x 70 Ft) 0009B - COVERED PATIO (15 Ft x 59 Ft) A - GAZEBO (9 Ft x 9 Ft) B - GAZEBO (9 Ft x 9 Ft)
Name GSF
14,610 2,210
22,760 28,540
13,250 7,000
1,390 1,467
11,463
Active Active Active Active Active Active Active Active Active Active Active Active
Active
Active Active Active
StatusType
Building Building Building Building Building Building Building Building Building Building Building Structure
Structure
Structure Structure Structure
Use Group Built Flrs Const
Business Business Residential Residential Business Business Assembly Business Business Business Assembly Assembly
Assembly
Assembly Assembly Assembly
Good Good Good Good Good Good Good Good Good Good Good Good
Good
Good Good Good
ConditionAsset Number
0042500003 0042500011 0042500008 0042500009 0042500010 0042500005 0042500004 0042500002 0042500012 0042500014 0042508104 0042508106
0042508107
0042508108 0042508103 0042508105
11 103,435
5 2,439
16 105,874
Buildings
Structures
Total
GSF
GSF
GSF
Summary
01/26/2015
Space Utilization By Function 00425 Gadsden Page: 1 of Date:
HOUSING
EDUCATION
FOOD SERVICE
SUGGESTED
NSF/
ENROLLEE
SUGGESTED
TOTAL
NSF
ACTUAL
TOTAL
NSF
TYPE OF SPACE
SUB TOTAL
SUB TOTAL
SUB TOTAL
Resident Men Resident Women Total Residents
Residents 236 Non Residents 24
260Total Students
(236)
(260)
(260)
DIFFERENCE
25,488
16,490
4,680
31,667
17,437
4,027
Lounge Other Shower/Toilet Sleeping excl. SPD( rooms; beds) Storage
Academic (260) Non-Academic
30 -- Advanced Career Training 24 -- Carpentry + 30 -- Cert. Nursing Asst.
30 -- Food Service + 30 -- Hotel/Motel Clerk 20 -- Human Services Worker 30 -- Office Administration 60 -- Security Services
Vocational Theory (54)
Dining (2 Servings) Food Preparation Food Storage
2,835 4,236 2,734
20,262 1,600
4,215 3,927
2,721 1,116
1,113
1,872 1,724
2,360 1,888 2,832
16,992 1,416
2,600 2,600
1,800 1,200 1,800
1,350 2,100
2,080 1,560 1,040
2,348
-98 3,270
1,615 1,327
-70 -84
-822 -106 -822
-1,151
-74
-208 -609
Vocations
6,179
-653
01/26/2015
Space Utilization By Function 00425 Gadsden Page: 2 of Date:
RECREATION
MEDICAL/DENTAL
ADMINISTRATION
STORAGE/SUPPORT
VACANT
SUGGESTED
NSF/
ENROLLEE
SUGGESTED
TOTAL
NSF
ACTUAL
TOTAL
NSF
TYPE OF SPACE
SUB TOTAL
SUB TOTAL
SUB TOTAL
SUB TOTAL
SUB TOTAL
TOTAL 271.05 70,473 75,162
(260)
(260)
(260)
(260)
(0)
DIFFERENCE
103,435
0.73
TOTAL GSF
NET TO GROSS RATIO
12,160
1,255
5,200
12,752
1,400
4,451
2,173
1,255
Canteen Gymnasium Hair Salon Lounges Meeting Room Men's Exercise Room Miscellaneous Recreation Pool Hall Recreation Office Recreation Storage Women's Exercise Room
Medical Only
Administration
Operations & Maintenance Warehouse
Vacant
4.83
7,832
1,484
1,400
4,451
1,288
1,255
2,080 3,120
7,832
1,484
-749
-1,195 -1,832
1,255
RESIDENT
NON-RESIDENT
(236)
(24) 15
50 11,800
-749
-3,027
4,689
Net Square Footage By Building Date: 01/26/2015 Page: 1
Center: GADSDEN (00425) of 4
HOUSING
Sleeping excl. SPD
Lounge
Storage
Shower/Toilet
Other
Function Suggested
NSF
11,062 9,200
2,835
1,600
1,520 1,214
3,906
0004 - FEMALE DORMITORY
0003 - MALE DORMITORY
0003 - MALE DORMITORY
0003 - MALE DORMITORY
0003 - MALE DORMITORY
0004 - FEMALE DORMITORY
0003 - MALE DORMITORY
0004 - FEMALE DORMITORY
Bldg Name Actual NSF Difference
20,262
2,835
1,600
2,734
4,236
Sub Total: 31,667
16,992
2,360
1,416
2,832
1,888
25,488
3,270
-98
2,348
( 236
6,179 rooms; beds rooms; beds
Page: 2
Center: GADSDEN (00425) of 4
EDUCATION
Academic
Vocational Theory (54)
Carpentry
Security Services
Food Service
Non-Academic
Hotel/Motel Clerk
Advanced Career Training
Office Administration
Cert. Nursing Asst.
Human Services Worker
Function Suggested
NSF
1,222
2,721
1,095
1,113
1,116
0006 - EDUCATION
0006 - EDUCATION
0006 - EDUCATION
0006 - EDUCATION
0006 - EDUCATION
0006 - EDUCATION
0006 - EDUCATION
0006 - EDUCATION
0001 - ADMIN/EDUCATION/WELLNESS
0014 - PHYSICAL FITNESS CENTER
0009 - CAFETERIA/CULINARY ARTS
0001 - ADMIN/EDUCATION/WELLNESS
0002 - COUNSELOR
0002 - COUNSELOR
0003 - MALE DORMITORY
0001 - ADMIN/EDUCATION/WELLNESS
0001 - ADMIN/EDUCATION/WELLNESS
0005 - DRIVER'S EDUCATION
0004 - FEMALE DORMITORY
0006 - EDUCATION
0013 - ACADEMIC
0001 - ADMIN/EDUCATION/WELLNESS
0006 - EDUCATION
0006 - EDUCATION
Bldg Name Actual NSF Difference
4,215
2,721
3,927
1,113
1,116
Sub Total: 17,437
2,600
1,800
2,100
1,800
2,600
1,350
1,200
16,490
1,615
-74
-1,151
-822
1,327
-70
-822
-84
-106
( 260
Page: 3
Center: GADSDEN (00425) of 4
FOOD SERVICE
RECREATION
MEDICAL/DENTAL
Dining (2 Servings)
Food Preparation
Food Storage
Gymnasium
Lounges
Miscellaneous Recreation
Pool Hall
Canteen
Hair Salon
Meeting Room
Men's Exercise Room
Women's Exercise Room
Recreation Storage
Recreation Office
Medical Only
Function Suggested
NSF
1,872
1,724
7,832
1,484
1,400
0009 - CAFETERIA/CULINARY ARTS
0009 - CAFETERIA/CULINARY ARTS
0009 - CAFETERIA/CULINARY ARTS
0014 - PHYSICAL FITNESS CENTER
0004 - FEMALE DORMITORY
0014 - PHYSICAL FITNESS CENTER
0004 - FEMALE DORMITORY
0004 - FEMALE DORMITORY
0004 - FEMALE DORMITORY
0004 - FEMALE DORMITORY
0014 - PHYSICAL FITNESS CENTER
0014 - PHYSICAL FITNESS CENTER
0004 - FEMALE DORMITORY
0014 - PHYSICAL FITNESS CENTER
0004 - FEMALE DORMITORY
0014 - PHYSICAL FITNESS CENTER
0001 - ADMIN/EDUCATION/WELLNESS
Bldg Name Actual NSF Difference
1,872
1,724
7,832
1,484
1,400
Sub Total:
Sub Total:
Sub Total:
4,027
12,752
1,400
2,080
1,560
1,040
1,255
4,680
12,160
1,255
-208
-609
-653
Page: 4
Center: GADSDEN (00425) of 4
ADMINISTRATION
STORAGE/SUPPORT
VACANT
Administration
Warehouse
Operations & Maintenance
Vacant
Function Suggested
NSF
4,265
1,255
0010 - GUARD HOUSE
0001 - ADMIN/EDUCATION/WELLNESS
0001 - ADMIN/EDUCATION/WELLNESS
0004 - FEMALE DORMITORY
0001 - ADMIN/EDUCATION/WELLNESS
0011 - VACANT
Bldg Name Actual NSF Difference
4,451
1,288
1,255
Sub Total:
Sub Total:
Sub Total:
4,451
2,173
1,255
5,200
3,120
2,080
5,200
5,200
-749
-1,832
-1,195
1,255
-749
-3,027
1,255
Environmental Management Report Center: GADSDEN (00425)
Page: 1 Date: 01/26/2015 of 1
SOLID & HAZARDOUS WASTE MANAGEMENT (RCRA)
Commercial Waste Service
HAZARDOUS MATERIALS STORAGE (EPCRA)
N/A N/A
N/A No
PETROLEUM UNDERGROUND STORAGE TANKS (RCRA)
N/A0
PETROLEUM ABOVEGROUND STORAGE TANKS (CWA)
ASBESTOS AND PCB MANAGEMENT (TSCA)
AIR POLLUTION CONTROL (CAA)
N/A None
Attainment
Solid Waste Disposal :
Hazardous Waste Generator :
Hazardous Waste ID :
Generator Classification :
Hazadous Materials Storage :
Hazardous Materials ID :
HazMat Storage Area :
HazMat Spill Response Plan :
Number of Regulated USTs :
Number of Un-regulated USTs :
Local Hazardous Use Permit :
LEPC Notification :
EPA Generator ID Number :
Hazardous Waste Disposal :
RCRA Compliance
ID LocationFuel Type Capacity
Number of ASTs :
Asbestos Survey Date :
Asbestos Type :
Asbestos Coordinator :
Coordinator Training Date:
Custodial/Maintenance Training :
AHERA Regulated :
Management Plan Approval :
PCB Transformer Testing :
PCB Transformers :
PCB-Contaminated Transformers :
Transformers Labelled :
Regional Air Quality :
Permitted Air Pollution Source :
Source Description :
Browning Ferris Industries, Inc.
No N/A
N/A N/A N/A
N/A
N/A N/A
Overfill Leak Corrosion
SPCC Plan Required : SPCC Plan Completed :
No N/A
No Survey Performed None
No No N/A No No
ID Fuel Type Capacity Location Overfill
Prevention Secondary ContainmentTank Status
Tank Status Prevention/Detection
Radon
Date: 01/26/2015Center : Gadsden (00425) Page: 1 of 1
0001 - ADMIN/EDUCATION/WELLNESS
0002 - COUNSELOR
0003 - MALE DORMITORY
0004 - FEMALE DORMITORY
0005 - DRIVER'S EDUCATION
0006 - EDUCATION
0009 - CAFETERIA/CULINARY ARTS
0010 - GUARD HOUSE
0011 - VACANT
0013 - ACADEMIC
0014 - PHYSICAL FITNESS CENTER
Bldg Name
09/28/2001
09/28/2001
09/28/2001
09/28/2001
09/28/2001
Test Date
Yes
No
Yes
Yes
No
Yes
Yes
No
No
N/A
No
Radon Testing
< 4 pCi
< 4 pCi
< 4 pCi
< 4 pCi
< 4 pCi
Test Result
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Mitigation Mitigation Date
RADON EXPLANATORY NOTES
The US Environmental Protection Agency (EPA) has established a radon action level of 4.0 picoCuries per liter (pCi/L). Occupied buildings with radon concentrations less than 4.0 pCi/L do not require radon mitigation; un-occupied buildings, or those buildings which are occupied only infrequently for brief periods of time, also do not require radon mitigation. Occupied buildings with radon concentrations greater than
4.0 pCi/L require radon mitigation and verification of radon reductions as soon as possible, with priority given to dormitories and student recreation buildings. Occupied buildings with radon concentrations greater than 20.0 pCi/L should be considered significant radon exposure hazards, and priority for mitigation should be given to buildings with these highly elevated radon concentrations.
Radon mitigation techniques include: (1) adjustment of the building HVAC system to create a positive pressure within the building; (2) sealing of foundation wall cracks, penetrations, or other openings;
(3) sealing crawlspace openings and sump pits; (4) installing an active subslab depressurization (ASD) system.
Site Description
Aerial view of Gadsdedn JCC
Page: 1 Date: 01/26/2015 of 4
Comments:
Paving Type for Roads & Parking
The road leading to Building 2 has a sinkhole.
Paving Type for Sidewalks
Asphalt Concrete
Comments:
Topography Buildings and Structures
Center is not fully enclosed by fencing.
ROADS, PARKING & SIDEWALKS
Water Source Water Authority Service Meter On-Site Treatment Plant
1. Water System
Treatment Type Storage Type Storage Capacity(Gallons)
NoMasterGadsden Water Works and Sewer BoardPublic Water Authority
Source Water Disinfection 0None
The lessor is responsible for maintenance of the water system. Only Physical Fitness Center Building 14 has an individual water meter.
Comments:
Comments:
Fire Hydrants On-Site Water Supply Storage Capacity
(Gallons) Pressure Source FD Response Time (Minutes)
Yes 0 5None Municipal
The Center is provided with fire hydrants for fire protection. A city fire station is one mile away with a response time of five minutes.
Number of Deficiencies = 1
SITE FEATURES
UTILITIES
2. Fire Protection System
Buildings Structures11 5Terraced
Surrounding
Outdoor Recreation
Residential
Basketball None
Northeast corner of Building 1
Northern portion of perimeter
Northern portion of perimeter
Western portion of site
Wrought Iron
Chain Link
Wood
Chain Link
Location Type
Maintenance Responsibility System Capacity Adequate System Condition
Lessor Lessor Yes Good
Separate Loop
No
Ownership Maintenance Responsibility System Capacity Adequate System Condition
Utility Utility Yes Good
Ownership
Roads & Parking Adequate Roads & Parking Condition Sidewalks Adequate Sidewalk Condition Yes Good Yes Good
Number of Deficiencies = 1
Fencing
Other Features
Page: 2 Date: 01/26/2015 of 4
Comments:
Sewage Treatment Flow
Sanitary drain collection is through the Lessor-owned sewer lines to publicly owned sewer lines.
Lessor
Publicly Owned Treatment Works
Lessor
Gravity
Maintenance ResponsibilityOwnership
Comments: A master gas meter is located in the yard near the northeast corner of Cafeteria/Culinary Arts Building 9. Individual buildings are not provided with gas meters.
Alabama Gas Corporation (Alagasco)
Comments:
Electric Company PCB Trans.
Transformer Mounting Transformer Ownership
Systems Ownership Maintenance Responsibility
Alabama Power Company
The primary overhead lines are brought from power poles on Lawier Circle along the campus northern boundary and North Fourth Place along the southern boundary. The system is radial, with multiple points of entry from the north and south. The secondary service to buildings on Center is mostly overhead with pole-mounted transformers.
Three buildings: Building 3-Male Dormitory, Building 4-Female Dormitory, and Building 14-Physical Fitness Center, each have an underground service with a pad-mounted transformer located in the back of the respective building.
All buildings have their own meter located on the exterior walls. Although all buildings are leased except Buildings 3 & 4-Dormitories, Building 10-Guard House, and Building 14-Physical Fitness, all pole- and pad-mounted transformers are owned and maintained by the utility and lessor.
Pole and Pad Utility
Utility Utility
No
12,470/7,200 Volts, 3-Phase
120/240, 120/208 Volts, 3-Phase, 4 WireUnderground
OverheadPrimary Service
Secondary Service
Distribution Characteristics
3. Sanitary Sewer System/ Sewage Treatment Plant
5. Fuel Distribution System Number of Deficiencies = 1
System Capacity Adequate System Condition
Yes Good
4. Storm Water System
Drain Type On-Site Storm Water Management
Surface Run-off, Underground N/A
Ownership Maintenance Responsibility System Capacity Adequate System Condition
Lessor Yes GoodLessor
Gas Company Metering
Master
Ownership Maintenance Responsibility System Capacity Adequate System Condition
Lessor Lessor Yes Good
7. Electrical (Service)
Transformer Maint Resp
Utility,Lessor
System Capacity Adequate System Condition
Yes Good
Generator
None
ATS MTS
No No
6. Central Plant: None
Metering Individual
Page: 3 Date: 01/26/2015 of 4
Comments:
Telephone Company
On-site Line Owner
The Job Corps Data Center (JCDC) provides local telephone service as part of the Job Corps Unified Communications Cluster (Cisco UCM). An ISDN PRI circuit, provided by the local Telco -- Bell South, is procured by the center for all inbound calls and outbound local calls. AT&T provides two T1 circuits for direct internet access and two T1 circuits for production traffic (Citrix, Voice, Testing, etc.) procured by the Networx Contract via the JCDC. All circuits terminate in the main telephone closet (MC) located on Building 1, first floor. Two Cisco routers in the MC transmit data to Cisco switches in each building by fiber optic cables.
The server is backed up by portable UPS modules.JCDC provides and maintains all data communication and VoIP systems on center. The fire alarm systems on leased and center-owned buildings are stand alone. There are CCTV cameras onsite. They are not in use. Male and Female Dormitory Buildings 3 and 4 have CCTV cameras installed in the corridors with color monitor in the RA office and a door alarm at the egress door on each floor.
Satellite TV is provided in the dormitories and cafeteria.
Bell South
Maint. Responsibility
Utility Utility
CCTV Cameras, Color Monitors, Door Alarms
There are no active or abandoned tanks on site.
STORAGE TANKS
Comments:
TypeStatus Location Owner Fuel Type
Capacity (Gallons) Install DateID Reg.
9. Electrical (Communication/Alarm/Security)
Purpose
Yes
Stand-Alone
VOIP
System Capacity Adequate System Condition
GoodYes
8. Electrical (Site Lighting)
Roadways Parking Walkways Building Outdoor Sports
Mounting
Control
Pole Pole Pole Building None
Photocell, Time Clock Photocell, Time Clock Photocell, Time Clock Photocell, Time Clock None
System Ownership Maintenance Responsibility System Capacity Adequate System Condition
Utility, Center, Lessor Utility, Center, Lessor Yes Good
Comments: All pole-mounted lights are owned and maintained by the utility company. Building-mounted exterior lights on leased buildings and on DOL owned buildings are owned and maintained by the lessor and the center respectively.
Number of Deficiencies = 6
Fire Alarm Security
Page: 4 Date: 01/26/2015 of 4
ACCESSIBILITY
Yes
Site information reflects the condition of the main campus on Valley Street. The center also leases a small portion of a building at the Broad Street campus of the Gadsden State Community College; information on this site is not included.
Comments:
NoNoNoNo
Nationally Registered Site
Site Eligible for National Register
Located in Historic District
Archaeological Significance
Earthquake Risk
Low Low LowLow LowIBC Low
LightningEarthquake Def. Authority Flooding Tornado Hurricane Forest
Fire
Number of Deficiencies = 2
Accessible Parking: Accessible Slope:
No
Curb Cuts:
Yes
Ramps:
YesNo
Site Accessible Route:
GENERAL SITE CONDITION
Rating X Good Fair Poor
HISTORIC PRESERVATION
NATURAL HAZARDS
The site condition is not impacting the functional use of the facilities.
The site condition IS impacting the functional use of the facilities.
The site condition IS SIGNIFICANTLY impacting the functional use of the facilities.
Active Energy Use Reduction Program
Active Water Use Reduction Program
Approximate or Measured Waste Recycled
Use of School Dude or CMMS for Preventative Maintenance
Green Purchasing Policy Practiced
Site Stormwater Absorption Measures in Place
Center has Onsite Renewable Energy (PV or Wind)
Center has a Chartered Green Committee & Roster
Center Uses Green Cleaning Practices
SUSTAINABILITY
NO
NO
NO
NO
NO
NO
NO
NO
Building Descriptions and Structures
BUILDING 1 - ADMIN/EDUCATION/WELLNESS
Building Descriptions
Page: 1 of 50
Building: 0001 - ADMIN/EDUCATION/WELLNESS
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Concrete Concrete Tees
Brick Masonry Concrete Panel Window Spandrel Panel
Wall Roof None Rigid
Metal Unit - Metal Frame Storefront - Metal Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership#Floors
Business 14,610 10,324 2 Leased 1964 Not Evaluated
Comments: There is grade level access to both floors.
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
N/A
Yes
Yes
Yes
Yes
Yes
Yes
N/A
Yes
Yes
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2.
Insulation4.
Exterior Doors5. Number of Deficiencies = 1
Material Drainage Year Life
Remaining Type Area Served
Single Ply Gutters and Downspouts 2007 13 Flat Entire Building
3. Roof
Entire Building
Area Served
Page: 2 of 50
Building: 0001 - ADMIN/EDUCATION/WELLNESS
INTERIOR FINISH
Carpet Ceramic Tile Concrete Vinyl Tile Wood
CMU Ceramic Tile Drywall Exposed Structure FRP Plywood Wood Paneling
Aluminum Storefront - Aluminum Frame Wood Unit - Metal Frame
Wood Unit - Wood Frame
VERTICAL CIRCULATION
Concrete Stairs
Awning Unit - Aluminum Frame; Single Glazing; Fixed - Aluminum Frame; Single Glazing;
Fixed - Metal Frame; Single Glazing; Hopper - Aluminum Frame; Single Glazing;
Acoustical Tile Fiberboard
Number of Deficiencies = 4
Windows6.
Floors1.
Interior Walls2. Number of Deficiencies = 1
3. Number of Deficiencies = 1
Interior Doors4.
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Through-the-wall heat pump unit serves the maintenance office on the 1st floor.
Heating is provided by a split system heat pump. The indoor air handler is manufactured by Carrier, model FB4ANF024 that serves the receiving property specialist clerk and copy/mail room.
Heating is provided by two furnaces located in the mechanical room that serve the 1st floor administration offices and the 2nd floor academic and medical areas.
Comments:
Comments:
Comments:
HVAC
Heat1.
Packaged Heat Pump (Air
Source)
Split Heat Pump (Air
Source)
Gas-Fired Furnace
Through-The- Wall Unit
Single Duct
Single Duct
None
Refrigerant
None
Electric
Electric
Electric
Natural
Natural
Mechanical
None
None
None
Offices
Storage
Classrooms and Offices
Ceilings
Page: 3 of 50
Building: 0001 - ADMIN/EDUCATION/WELLNESS
Mechanical Restroom
Ventilation Area Served
Split Direct Expansion (Air
Source)
Packaged Heat Pump (Air
Source)
Split Heat Pump (Air
Source)
Split Direct Expansion (Air
Source)
Packaged Direct
Expansion (Air Source)
Single Duct
Through-The- Wall Unit
Single Duct
Fan Coil
Window Unit
Refrigerant
None
Refrigerant
Refrigerant
None
Electric
Electric
Electric
Electric
Electric
Mechanical
Natural
Mechanical
Natural
Natural
None
None
None
None
None
Classrooms and Offices
Offices
Storage
Electronic Equipment
Room
Classrooms
Exhaust Ventilation
Two DX split -systems provide cooling to the 1st floor administration offices and the 2nd floor academic and medical areas. The outdoor air-cooled condensing units are manufactured by Rheem model RAWE120CAZ with a 10 ton cooling capacity and built in 06/2008 and RAWE241CAZ with a 20 ton cooling capacity and built in 06/2005.
Through-the-wall heat pump unit serves the maintenance office on the 1st floor.
An outdoor heat pump provides cooling to a DX coil in an indoor air handler manufactured by Carrier, model FB4ANF024 that serves the receiving property specialist clerk and copy/mail room.
The server room on 1st floor is served by a split system A/C unit. The condensing unit is located on the roof that provides cooling to an indoor ductless evaporating unit.
Two window units serve the business tech classes. These are no longer in operation and have been abandoned in-place.
Comments:
Comments:
Comments:
Comments:
Comments:
Ventilation2.
System Type
Number of Deficiencies = 2
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
3. Air Conditioning
Page: 4 of 50
Building: 0001 - ADMIN/EDUCATION/WELLNESS
Domestic hot water is provided by an electric water heater located under the counter in the women's toilet and manufactured by Rheem, model 61VP10S, with a 10 gallon capacity and 2 kW input.
Comments:
Cast-Iron None Cast-Iron
Electric Water Cooler Hose Bibb Lavatory Service Sink Sink Urinal Water Closet (Flush Valve) Water Closet (Tank)
Gas (Natural)
None None ABC Type Fire Extinguisher
Comments: This building is a jointly used by the Center and Gadsden State Community College (GSCC). The building electrical service originates from a bank of three pole-mounted transformers and a meter located on the north side of the building. Service terminates in a main distribution panelboard located in the GSCC main electrical room. Two 225A panels located on the second floor serve the admin/education/wellness facilities.
Copper Copper Gas-Fired None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
High Intensity Discharge (HID)
Comments: Exterior building-mounted and surrounding area pole-mounted light fixtures are controlled by time clock and photocells.
Main Distribution Panel 120/208V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
FIRE PROTECTION
ELECTRICAL SERVICES Number of Deficiencies = 3
Exterior Lighting1.
LIGHTING
Page: 5 of 50
Building: 0001 - ADMIN/EDUCATION/WELLNESS
FIRE ALARM
Comments: The fire alarm control/annunciator panel located in the corridor near Center Director's office on the first floor is a Notifier Model SFP-400.
Audible Alarm Control/Annunciator Panel Heat Detector Manual Pull Station Smoke Detector Visual Alarm
Connected to Main System None None None
Telephone Security Public Address Television
Comments: Recorded footcandle levels include natural light contribution.
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
Offices
Storage Rooms
Classrooms
Medical/Dental
Corridors & Stairs
Toilets
Reception
Area Recommended Level
Recorded Level Light Type
Battery Backup Battery Backup
Emergency Exit
Number of Deficiencies = 1
GENERAL BUILDING CONDITION
Rating X Good
Fair Poor
Interior Lighting2.
Emergency /Exit Lighting3. Number of Deficiencies = 1
COMMUNICATION
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
Electric Water Gas No NoYes
BUILDING UTILITY METERING
Structure: Good Exterior: Good Interior: Good Mechanical: Good Electrical: Good
Type Location
CARBON MONOXIDE DETECTION
Detection Required No
Number of Deficiencies = 0
BUILDING 2 - COUNSELOR
Page: 6 of 50
Building: 0002 - COUNSELOR
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Wood Wood
Wood Siding
Wall Roof Batt Batt
Metal Unit - Metal Frame Storefront - Aluminum Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership#Floors
Business 2,210 1,192 1 Owned 1996 Not Evaluated
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
Yes
Yes
Yes
N/A
Yes
Yes
Yes
N/A
No
Yes
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2. Number of Deficiencies = 1
Insulation4.
Exterior Doors5.
Material Drainage Year Life
Remaining Type Area Served
Asphalt Shingles Surface Run-off 1996 2 Hip Entire Building
3. Roof
Page: 7 of 50
Building: 0002 - COUNSELOR
INTERIOR FINISH
Carpet Concrete Vinyl Tile
Drywall
Wood Unit - Metal Frame
Mechanical Restroom
Ventilation Area Served
VERTICAL CIRCULATION
Concrete Stairs Ramp
Comments: There are concrete stairs and a concrete ramp leading to the entries.
Sliding - Metal Frame; Double Glazing;
Acoustical Tile
Exhaust Ventilation
Number of Deficiencies = 1
Windows6.
Floors1.
Interior Walls2.
3.
Interior Doors4.
Heat Source
Heat Distribution
Piping System
Co…