15-WHS - CTAE RMA Permit-Bid Set Drawings 04022026.pdf
PDF 4 MB Posted
- Attached to
- Woodstock HS CTAE RMA
- Solicitation number
- 2026.RMA.13.01
- Issued by
- Cherokee County, Georgia
About this file
This is a Permit/Bid Set of construction drawings issued by Cooper Carry Architects for the Cherokee County School District (CCSD) in Georgia for the Woodstock HS CTAE RMA project located at 2010 Towne Lake Hills S. Drive, Woodstock, Georgia 30189. The project encompasses renovations to create Career, Technical, and Agricultural Education (CTAE) laboratory spaces within the existing Woodstock High School facility, with 22 new instructional units being added to the existing 96 units, totaling 108 instructional units for a facility with 2,100 Full-Time Equivalent (FTE) students. The scope of work includes demolition and renovation of approximately 4,361 square feet of space to accommodate five specialized lab areas: Information Technology/Cybersecurity Lab (1,306 SF), Flight Operations Lab (2,585 SF), Engineering Lab, Radio Studio, Control Room, and TV Studio, along with supporting office, storage, electrical, and IDF spaces. A mandatory Pre-Proposal Conference and site visit is scheduled for 1:30 p.m. on Monday, April 13, 2026, at the Cherokee County School District Support Service Office, 200 Mountain Brook Ct, Canton, Georgia 30115. The construction documents are issued for permitting and bidding purposes as of April 2, 2026.
The project involves comprehensive mechanical, plumbing, electrical, and fire alarm systems design and installation. The construction type is IBC 11B with full sprinkler protection per NFPA 13, and the facility is classified as an Educational occupancy. New ductless split HVAC systems (four units) are specified for targeted climate control, new electrical distribution including a 75 KVA transformer and new panels (LPA, LPB, HPA), LED lighting with occupancy sensors, and complete fire alarm and security systems integration. All work must comply with the International Building Code 2024 with 2026 Georgia amendments, the International Fire Code 2024, NFPA 101 Life Safety Code 2024, and the 2023 National Electrical Code with 2026 Georgia amendments. The MEP engineering is provided by Matheson-Ball & Associates, Inc., and the architectural services by Cooper Carry. Existing building components including mechanical ductwork, casework, and storefront systems are designated to remain and be protected during construction, with selective demolition of existing ceilings, flooring, fixtures, and systems specified in the detailed demolition plans provided throughout the document set.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
191 Peachtree Street NE Suite 2400
Atlanta, GA 30303-1770
(404) 237-2000 coopercarry.com
Principal-in-Charge
Project Manager
Project Architect
Staff Architect
Project No.
Date
Drawing No.
A
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
B C
D E
F G
H J
K L
M N
P
A B
C D
E F
G H
J K
L M
N P
© 2026 COOPER CARRY
ISSUED FOR CONSTRUCTION
GA DEPT OF EDUCATION DATA
FACILITY CODE: 628-1605-1320.01
FTE FOR THIS SITE: 2100
INSTRUCTIONAL UNITS: 108 (96 EXISTING,
22 NEW)
A u to d e s k D o c s /2
W o o d s to c k H
S
C T
A E l a b s /W
O O
D S
T O
C K
H S
C
T A
E L
A B
S V
.r v t
/1
/2
:0
:5
P
M
G0.00
04/02/2026
20260084SOPHIA TARKHAN
BRIAN MITCHELL
CLAIRE COUVILLON
COVER SHEET
WOODSTOCK HS CTAE RMA
2010 TOWNE LAKE HILLS S. DR.
WOODSTOCK, GA 30189
CHEROKEE COUNTY SCHOOL SYSTEM
P R
O
JE
C T
N U
M B
E R
: 2
P
R O
JE
C
T N
A M
E : W
O O
D S
TO
C
K H
S C
TA
E
R M
A S
H E
E T
N U
M B
E R
: G 0.
C O
V E
R S
H E
E T
WOODSTOCK HS CTAE RMA
2010 TOWNE LAKE HILLS S. DRIVE
WOODSTOCK, GA 30189
SCOPE / PROJECT TYPE
PERMIT/BID SET
04/02/2026
MEP ENGINEERS
MATHESON-BALL & ASSOCIATES, INC.
225 REFORMATION PKWY
SUITE 220
CANTON, GA 30144
770-751-0773
WWW.MATHESONBALL.COM
ISSUANCES
No. Drawing Issue Description Date
PERMIT/BID SET 04/02/2026
GENERAL NOTES
A. GENERAL NOTES:
1.THE CONTRACT, ADDENDA, SUPPLEMENTAL CONDITIONS, GENERAL REQUIREMENTS, GENERAL
CONDITIONS, AND TECHNICAL SPECIFICATIONS SHALL TAKE PRECEDENCE OVER THESE GENERAL NOTES.
ANY CONFLICT BETWEEN THESE GENERAL NOTES AND LANGUAGE FOUND IN THE ABOVE DOCUMENTS OR IN THE DRAWINGS OR IN ANY OTHER CONTRACT DOCUMENT SHALL BE BROUGHT TO THE ATTENTION OF
THE ARCHITECT IMMEDIATELY FOR FURTHER CLARIFICATION.
2. CONTRACTOR SHALL PROVIDE COMPLETE SYSTEMS AND ASSEMBLIES THAT INCLUDE ALL COMPONENTS NECESSARY FOR A FULLY FUNCTIONAL ASSEMBLY SATISFYING THE DESIGN INTENT, COMPLY WITH THE
REQUIREMENTS INDICATED IN THE CONTRACT DOCUMENTS AND READY FOR THE INTENDED USE.
REFERENCE CONDITIONS OF THE CONTRACT AND/OR GENERAL REQUIREMENTS FOR ADDITIONAL
INFORMATION.
3. REFERENCE CONDITIONS OF THE CONTRACT AND/OR GENERAL REQUIREMENTS FOR ANY OCCUPANCY
RESTRICTIONS OR REQUIREMENTS DURING CONSTRUCTION.
4. REFERENCE CONDITIONS OF THE CONTRACT AND/OR GENERAL REQUIREMENTS REGARDING
REQUIREMENTS FOR DOCUMENTATION AND REPORTING OF FIELD CONDITIONS BY THE CONTRACTOR AND
COORDINATION WITH THE CONTRACT DOCUMENTS.
5. REFERENCE CONDITIONS OF THE CONTRACT AND/OR GENERAL REQUIREMENTS REGARDING
COORDINATION OF THE WORK OR OTHER SPECIAL COORDINATION REQUIREMENTS.
B. DEFINITIONS:
1. “TYPICAL” OR “TYP.” INDICATES IDENTICAL COMPLETE SYSTEM, ASSEMBLY OR COMPONENT SHALL BE
PROVIDED FOR EACH OCCURRENCE OF THE CONDITION NOTED.
2. “SIMILAR” INDICATES COMPLETE SYSTEM, ASSEMBLY AND COMPONENTS SHALL BE PROVIDED, INCLUDING ANY ADJUSTMENTS REQUIRED DUE TO VARIATION AT A PARTICULAR CONDITION, RESULTING IN COMPARABLE CHARACTERISTICS FOR THE “SIMILAR” CONDITION NOTED. THE ARCHITECT SHALL BE THE
SOLE JUDGE OF A SIMILAR CONDITION’S COMPLIANCE WITH THE DESIGN INTENT.
3. “AS REQUIRED” INDICATES ITEMS OF WORK REQUIRED TO PROVIDE FOR A COMPLETE SYSTEM, ASSEMBLY OR COMPONENT AS INDICATED IN THE CONTRACT DOCUMENTS. ALL COMPONENTS OF THE NOTED SYSTEM SHALL BE PROVIDED, INSTALLED, COMPLETE AND READY FOR THE INTENDED USE.
4. “ALIGN” INDICATES ACCURATELY PROVIDE FINISH FACES OF MATERIALS IN STRAIGHT, TRUE, LEVEL AND/OR PLUMB RELATION TO ADJACENT SURFACES WITHIN TOLERANCES DEFINED IN THE TECHNICAL
SPECIFICATIONS.
5. REFERENCE DIVISION 01 OF THE PROJECT MANUAL FOR ADDITIONAL DEFINITIONS AND CLARIFICATIONS.
C. DRAWINGS
1. DRAWINGS SHALL NOT BE SCALED FOR DETERMINATION OF LENGTHS, FIT, OR QUANTITIES OF MATERIALS, ETC. DIMENSIONS SHOWN ON THE DRAWINGS SHALL INDICATE THE REQUIRED SIZES, CLEARANCES, AND DIMENSIONAL RELATIONSHIPS BETWEEN SYSTEMS, ASSEMBLIES, AND COMPONENTS.
2. THE CONTRACT DOCUMENTS CONSIST OF THIS SET OF DRAWINGS, ADDENDA, BULLETINS,
CONSTRUCTION CHANGE DIRECTIVES, CHANGE ORDERS, THE CONTRACT BETWEEN OWNER AND
CONTRACTOR, CONDITIONS OF THE CONTRACT, AND ANY OTHER INFORMATION WRITTEN AND MUTUALLY
AGREED UPON BETWEEN THE OWNER AND THE CONTRACTOR.
3. THESE DRAWINGS ARE COMPLEMENTARY AND INTERRELATED; WORK OF ANY INDIVIDUAL TRADE IS NOT
NECESSARILY CONFINED TO SPECIFIC DOCUMENTS, CHAPTERS, OR LOCATIONS.
4. COORDINATE LOCATIONS AND/OR ELEVATIONS OF REGISTERS, GRILLES, LOUVERS, DUCTS, UNIT HEATERS, PANELS, ETC. WITH MECHANICAL AND ELECTRICAL CONTRACTORS AND ARCHITECTURAL
DRAWINGS.
5. WHERE A DETAIL IS SHOWN FOR ONE CONDITION, IT SHALL APPLY TO ALL LIKE OR SIMILAR CONDITIONS, EVEN THOUGH NOT SPECIFICALLY MARKED ON THE DRAWINGS.
6. 3-D PERSPECTIVE VIEWS ARE PROVIDED FOR REFERENCE TO ASSIST THE CONTRACTOR IN
UNDERSTANDING THE DESIGN CONCEPT FOR ARCHITECTURAL COMPONENTS AND ARE NOT INTENDED TO SUPERCEDE INFORMATION CONTAINED IN OTHER CONTRACTOR DOCUMENTS RELATING TO THIS WORK.
ISSUES REQUIRING CLARIFICATION AND/OR INTERPRETATION OF THESE PERSPECTIVE VIEWS SHALL BE
DIRECTED TO THE ARCHITECT IN WRITING.
D. DIMENSIONS:
1. DIMENSIONS ARE INDICATED TO THE CENTERLINE OF STRUCTURAL GRID, FACE OF CAST-IN-PLACE CONCRETE PARTITION, FACE OF UNIT MASONRY PARTITION, AND/OR TO THE FINISH FACE OF INTERIOR
PARTITIONS AND PARTITIONS AS SCHEDULED, UNLESS NOTED OTHERWISE.
2. FLOOR ELEVATIONS ARE INDICATED TO THE TOP SURFACE OF THE “STRUCTURAL” SLAB, UNLESS NOTED
OTHERWISE.
3. CEILING HEIGHTS ARE INDICATED FROM FINISHED FLOOR ELEVATIONS TO THE FINISH FACE OF SUSPENDED CEILING SYSTEMS OR FACE OF FINISH MATERIALS, AS INDICATED OR SCHEDULED.
4. DIMENSIONS SHOWN ON THE DRAWINGS SHALL INDICATE THE REQUIRED SIZES, CLEARANCES, AND
DIMENSIONAL RELATIONSHIPS BETWEEN PROJECT SYSTEMS, ASSEMBLIES AND COMPONENTS.
DIMENSIONS SHALL NOT BE DETERMINED BY SCALING THE DRAWINGS.
5. WHERE EQUIPMENT OR COMPONENTS HAVE DIMENSIONAL VARIATION DEPENDENT ON THE SELECTED MANUFACTURER, THE CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE ADJOINING CONSTRUCTION
TO ACCOMMODATE THE SELECTED MANUFACTURER’S REQUIREMENTS.
6. REFERENCE DIVISION 01 OF THE PROJECT MANUAL FOR ADDITIONAL REQUIREMENTS FOR
COORDINATION OF DRAWINGS AND DIMENSIONS.
E. PROJECT NOTES:
1. FIELD VERIFY LOCATION OF UTILITIES WITHIN WALLS TO BE REMOVED.
2. CONTRACTOR TO REPAIR/REPLACE ANY MATERIALS SHOWN TO REMAIN IF DAMAGED DURING
CONSTRUCTION.
3. COORDINATE WITH OWNER WHEN UTILITIES ARE TO BE TURNED OFF.
4. COORDINATE WITH OWNER TO ASSIGN A DEDICATED CONTRACTORS ENTRANCE INTO THE WORK AREA.
5. EXIST. WINDOW BLINDS TO REMAIN. PROTECT FROM DAMAGE.
191 Peachtree Street NE Suite 2400
Atlanta, GA 30303-1770
(404) 237-2000 coopercarry.com
Principal-in-Charge
Project Manager
Project Architect
Staff Architect
Project No.
Date
Drawing No.
A
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
B C
D E
F G
H J
K L
M N
P
A B
C D
E F
G H
J K
L M
N P
© 2026 COOPER CARRY
ISSUED FOR CONSTRUCTION
GA DEPT OF EDUCATION DATA
FACILITY CODE: 628-1605-1320.01
FTE FOR THIS SITE: 2100
INSTRUCTIONAL UNITS: 108 (96 EXISTING,
22 NEW)
A u to d e s k D o c s /2
W o o d s to c k H
S
C T
A E l a b s /W
O O
D S
T O
C K
H S
C
T A
E L
A B
S V
.r v t
/1
/2
:5
:3
P
M
G0.01
04/02/2026
20260084SOPHIA TARKHAN
PROJECT ARCHITECT
CLAIRE COUVILLON
DRAWING INDEX
WOODSTOCK HS CTAE RMA
2010 TOWNE LAKE HILLS S. DR.
WOODSTOCK, GA 30189
CHEROKEE COUNTY SCHOOL SYSTEM
P R
O
JE
C T
N U
M B
E R
: 2
P
R O
JE
C
T N
A M
E : W
O O
D S
TO
C
K H
S C
TA
E
R M
A S
H E
E T
N U
M B
E R
: G 0.
D R
A W
IN
G
IN
D
E X
DRAWING INDEX
SHEET NO. SHEET NAME
GENERAL
G0.00 COVER SHEET
G0.01 DRAWING INDEX
G0.02 GENERAL INFORMATION
G1.01 MEANS OF EGRESS PLAN
ARCHITECTURE
A0.1 OVERALL FLOOR PLAN - HIGH SCHOOL
A1.00 DEMOLITION FLOOR PLAN
A1.11 PROPOSED & DIMENSIONED FLOOR PLANS
A1.12 FINISH PLAN & SCHEDULE
A2.10 REFLECTED CEILING PLANS
A3.11 ENLARGED PLANS & DETAILS
A9.00 INTERIOR PARTITIONS
A9.10 DOOR SCHEDULE AND TYPES
MECHANICAL
M1.0 FLOOR PLAN - HVAC DEMO
M1.1 FLOOR PLAN - HVAC
M2.0 VAC SCHEDULES & DETAILS
PLUMBING
P1.0 FLOOR PLAN - PLUMBING
ELECTRICAL
E0.1 SITE PLAN
E0.2 FLOOR PLAN - DEMO
E1.1 FLOOR PLAN - POWER
E2.1 CEILING PLAN - LIGHTING
E3.1 FLOOR PLAN - SYSTEMS
E4.1 FLOOR PLAN - FIRE ALARM
E5.1 ELECTRICAL SCHEDULES
E5.2 ELECTRICAL DETAILS
EM1.1 FLOOR PLAN - HVAC POWER
ISSUANCES
ABBREVIATIONS
A
ACP ACOUSTICAL CEILING PANEL
AD AREA DRAIN
ADJ ADJACENT
ADMIN ADMINISTRATION
ADA AMERICANS W/ DISABILITIES ACT
AFF ABOVE FINISHED FLOOR
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZE(D)
APPROX APPROXIMATE
ARCH ARCHITECT(URAL)
ASPH ASPHALT
ASSY ASSEMBLY
B
BD BOARD
BITUM BITUMIN(OUS)
BLDG BUILDING
BUR BUILT-UP ROOFING
C
CB CATCH BASIN
CER CERAMIC
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLO CLOSET
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONST CONSTRUCTION
CONT CONTINUOUS
COORD COORDINATE
CPT CARPET
CT CERAMIC TILE
CTR CENTER
D
DBL DOUBLE
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIM DIMENSION
DISP DISPENSER
DS DOWNSPOUT
DR DOOR
DWG DRAWING
E
EA EACH
EIFS EXTERIOR INSULATION &
FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC(AL)
ELEV ELEVATOR
EOS EDGE OF SLAB
EPS EXPANDED MOLDED POLYSTYRENE
BOARD (INSULATION)
XPS EXTRUDED POLYSTYRENE
BOARD (INSULATION)
EQ EQUAL
EQUIP EQUIPMENT
ESCAL ESCALATOR
EXH EXHAUST
F
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FACE
FHA FAIR HOUSING ACT
FHC FIRE HOSE CABINET
FIN FLR FINISH FLOOR
FIXT FIXTURE
FLR FLOOR
FLG FLOORING
FLUOR FLUORESCENT
FOS FACE OF STUD
FRT FIRE RETARDANT TREATED
G
GA GAGE
GALV GALVANIZED
GFRC
GLASS FIBER REINFORCED CONCRETE
GFRG GLASS FIBER REINFORCED GYPSUM
GFRP GLASS FIBER REINFORCED PLASTIC
H
HB HOSE BIBB
HC HANDICAP
HM HOLLOW METAL
HYD HYDRANT
I
ID INSIDE DIAMETER
IIC IMPACT ISOLATION CLASS
INFO INFORMATION
INSUL INSULATION
IRMA INVERTED ROOF
MEMBRANE ASSEMBLY
J
JAN JANITOR
L
LAV LAVATORY
M
MAX MAXIMUM
MECH MECHANICAL
MEZZ MEZZANINE
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
N
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NTS NOT TO SCALE
O
ON CENTEROC
OD OUTSIDE DIAMETER
OPNG OPENING
OPP OPPOSITE (HAND)
ORD OVERFLOW ROOF DRAIN
P
PL PROPERTY LINE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLYWD PLYWOOD
POL POLISHED
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT
Q
QT QUARRY TILE
R
R VALUE THERMAL RESISTANCE
RB RESILIENT BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REF REFERENCE
REQD REQUIRED
RM ROOM
RO ROUGH OPENING
S
SAB SOUND ATTENUATION
BLANKET
SCHED SCHEDULE
SD STORM DRAIN
SHT SHEET
SIM SIMILAR
SQ SQUARE
SPKR SPEAKER
SPKLR SPRINKLER
STC SOUND TRANSMISSION
COEFFICIENT
STD STANDARD
STOR STORAGE
STRUC STRUCTURAL
SST STAINLESS STEEL
SUSP SUSPEND(ED)
SUSP.CLG SUSPENDED CEILING
SV SHEET VINYL
T
T&G TONGUE & GROOVE
TEL TELEPHONE
THK THICKNESS
THRU THROUGH
TYP TYPICAL
U
UL UNDERWRITERS LABORATORY
UNO UNLESS NOTED OTHERWISE
V
VCT VINYL COMPOSITION TILE
VIF VERIFY IN FIELD
VOL VOLUME
VT VINYL TILE
VWC VINYL PARTITION COVERING
W
WC WATER CLOSET
WD WOOD
W/O WITHOUT
O.T.S. OPEN TO STRUCTURE
STL STEEL
ACC ACCESSIBLE
GYP. BD. GYPSUM BOARD
CFMF COLD FORMED METAL FRAMING
00 View Name
SCALE: 1/8" = 1'-0"A00.00A00.00
DRAWING TITLE
00 View Name
SCALE: 1/8" = 1'-0"A00.00
DRAWING NUMBER
SHEET NUMBER ON WHICH
DRAWING ORIGINATES
SHEET NUMBER ON WHICH
DRAWING APPEARS
DRAWING TITLE
DRAWING NUMBER
SHEET NUMBER ON WHICH
DRAWING APPEARS
SECTION MARKER
SECTION DRAWING NUMBER
SHEET NUMBER ON WHICH
SECTION IS DRAWN
A01.01
SIM
INTERIOR ELEVATION MARKER
A01.01
RATED PARTITION LEGEND
1 HOUR SEPARATION ASSEMBLY
OR FIRE PARTITION
2 HOUR SEPARATION ASSEMBLY
OR FIRE PARTITION
3 HOUR SEPARATION ASSEMBLY
OR FIRE PARTITION
4 HOUR SEPARATION ASSEMBLY
OR FIRE PARTITION
PARTITION TYPE MARKER
PARTITION TYPE
-SEE FLOOR PLANS
DIMENSIONAL STANDARDS 88.8
2 3/4"
CLEAR
2" 3/4"
FINISH FACE
(U.N.O.)
CRITICAL FINISHED
DIMENSION
DIMENSION TO
CENTERLINE
OF COLUMN
MISC. TAGS
FIRST FLOOR LEVEL
EL. 0' 00"FLOOR ELEVATION SYMBOL
OS478-WX
GENERAL KEYNOTES, ACCESSORY TAGS,
AND/OR FIXTURE TAGS - REFERENCE DRAWINGS
SPOT ELEVATION SYMBOL 8' 0" A.F.F. 8' 0" A.F.F.
REVISION CLOUD
REVISION CLOUD
REVISION NUMBER
DOOR NUMBER SYMBOL
DIGITS COORDINATE WITH ROOM NUMBERS
WINDOW TYPE
COLUMN MARKER 88.8
88.8 88.8
NEW EXISTING
ROOM TAG
CEILING HEIGHT MARKER
20' 10 3/8" ACT8
20' 10 3/8"
20' 10 3/8"P00 ACT8
CEILING HEIGHT
FINISH COLOR
CEILING MATERIAL
PROJECT WILL USE ONE OF THESE MARKERS
CURTAIN PARTITION GLASS & PANEL TYPES
G1 G1
SYMBOLS
SHEET NUMBER ON WHICH
ELEVATION IS DRAWN
ELEVATION DRAWING NUMBER
88.8
SMOKE SEPARATION ASSEMBLY
00000
ROOM NAME
EXISTING PARTITION TO REMAIN
NEW PARTITION
MATERIALS LEGEND
31 20 00 CRUSHED ROCK - GRAVEL FILL -
POROUS FILL
31 20 00 EARTH - UNDISTURBED
31 20 00 EARTH - COMPACTED FILL
31 20 00 SAND
03 30 00 CONCRETE
04 05 00 GROUT
04 20 00 BRICK MASONRY
04 20 00 CONCRETE MASONRY UNIT -
SMALL SCALE
04 20 00 CONCRETE MASONRY UNIT -
LARGE SCALE
04 20 00 ROUGH STONE
04 72 00 CAST STONE MASONRY
05 00 00 ALUMINUM
05 00 00 BRASS - BRONZE
05 00 00 STEEL
05 53 00 GRATINGS, SECTION
06 10 00 PLYWOOD OR EXTERIOR
SHEATHING
06 10 00 WOOD BLOCKING OR SHIM
06 10 00 WOOD FRAMING - CONTINUOUS
07 21 00 BATT INSULATION
07 80 00 SEMI-RIGID INSULATION -
MINERAL WOOL BLANKET
07 21 00 RIGID INSULATION
DESCRIPTION SYMBOL
SPEC
SECTION
07 80 00 SPRAY-ON MINERAL WOOL BLANKET
OR INSULATION
APPLICABLE CODES
BUILDING: INTERNATIONAL BUILDING CODE, 2024 WITH 2026 GA AMENDMENTS
FIRE: INTERNATIONAL FIRE CODE, 2024 EDITION
LIFE SAFETY: NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 101 LIFE SAFETY CODE, 2024
MECHANICAL: INTERNATIONAL MECHANICAL CODE, 2024 EDITION WITH 2026 GA AMENDMENTS
PLUMBING: INTERNATIONAL PLUMBING CODE, 2024 EDITION WITH 2026 GA AMENDMENTS
ELECTRICAL: NATIONAL ELECTRICAL CODE, 2023 EDITION WITH 2026 GA AMENDMENTS
GAS: INTERNATIONAL FUEL GAS CODE, 2024 EDITION WITH 2026 GA AMENDMENTS
ENERGY: INTERNATIONAL ENERGY CONSERVATION CODE, 2015 WITH 2023 GA AMENDMENTS
ACCESSIBILITY: U.S.D.O.J. 2010 ACCESSIBILITY STANDARDS
FAIR HOUSING: FEDERAL FAIR HOUSING ACT GUIDELINES 1990
EXIT REQUIREMENTS
DEAD END CORRIDOR (MAX.)
(IBC SECTION 1020.4; LSC SECTION 7.5.1.5)
EDUCATION: 5- FT WITH AUTOMATIC SPRINKLERS
COMMON PATH OF TRAVEL (MAX.)
(IBC SECTION 1006.2.1; LSC SECTION 7.5.1.1.4)
100FT WITH AUTOMATIC SPRINKLERS
SINGLE EXIT ALLOWED
(IBC SECTION 1006.3.3; LSC SECTION 7.4.1)
< 50 PEOPLE
MAXIMUM EXIT ACCESS TRAVEL DISTANCE
(IBC TABLE 1017.2; LSC SECTION 7.5)
1/3 DIAGONAL OF FLOOR OR SPACE WHERE
PROTECTED BY AN APPROVED AUTOMATIC SPRINKLER
MINIMUM STAIR WIDTH
(IBC SECTION 1005.3, 1011.2; LSC SECTION 7.2.2.2.1.2)
N/A
MINIMUM CORRIDOR WIDTH
(IBC SECTION 1005.1, TABLE 1020.2; LSC SECTION 7.3.4)
EDUCATION: 6 FT. MIN. CLEAR WIDTH
WHERE SERVING <100 OCCUPANTS = 44 INCHES MIN.
MINIMUM NO. OF EXITS REQUIRED
(IBC SECTION 1006.2; LSC SECTION 7.4)
OCCUPANT LOAD 1-500 2 EXITS
OCCUPANT LOAD 501-1000 3 EXITS
OCCUPANT LOAD >1000 4 EXITS
EDUCATION: 200FT WITH AUTOMATIC SPRINKLERS
EXIT SEPARATION (MIN.)
(IBC SECTION 1007; LSC SECTION 7.5.1.3)
OCCUPANCY CLASSIFICATIONS
PRIMARY OCCUPANCY:
OCCUPANCY CLASSIFICATION
AND USE
EDUCATION
IBC - CHAPTER 3
FUNCTION IBC TABLE 1004.5
OCCUPANT LOAD FACTOR LSC TABLE 7.3.1.2
INTERNATIONAL
BUILDING CODE
LIFE SAFETY CODE
LSC TABLE 7.3.1.2
LSC CHAPTER 6.1
IBC TABLE 1004.5
BUILDING DATA
CONSTRUCTION TYPE: IBC - 11B NFPA - 11(000)
SPRINKLERS:
(IBC SECTION 903; LSC SECTION 9.7.1)
YES NFPA 13 SUPERVISED YES
STANDPIPES:
(IBC SECTION 905; LSC SECTION 9.10)
NO - -
FIRE DISTRICT:
(REFERENCE LOCAL AUTHORITY)
NO - -
HIGH RISE:
(IBC SECTION 403)
NO - -
MEZZANINE:
(IBC SECTION 505)
NO - -
FIRE ALARM:
(IBC SECTION 907; LSC SECTION 9.6)
YES MANUAL / AUTOMATIC -
BUILDING AREAS
ACTUAL AREA: ALLOWABLE AREA PER FLOOR:
FLOOR NO.: USE /
OCC.:
ACTUAL AREA
PROVIDED
A + B = C
(A)
ALLOWABLE
FLOOR AREA
(TABLE 506.2)
(B)
FRONTAGE
INCREASE
(IBC 506.3)
(C)
INCREASED
ALLOWABLE
AREA / FLR
AFFECTED
AREA
4,361E N/A N/A 4,361
TOTAL AFFECTED AREA: 4,361 TOTAL ALL FLOORS: 4,361
BUILDING HEIGHTS
ACTUAL ALLOWABLE
EDUCATION, E
ALLOWABLE
HEIGHT
(IBC TABLE
504.3)
75'-0"
ALLOWABLE
NUMBER OF
STORIES
(IBC TABLE
504.4)
4 STORIES
N/A
TOTAL
ALLOWABLE
4 STORIES
FRONTAGE
INCREASE
(IBC TABLE
506.2)
ACTUAL
PROVIDED
75'-0"3
1 STORY
14'-8"
OCCUPANCY
TYPE:
ALL WORK CONTAINED WITHING FOOTPRINT OF EXISTING BUILDING
FIRE RESISTANCE RATINGS
BUILDING ELEMENTS:
STRUCTURAL FRAME:
RATING (HRS) REMARKS
BEARING PARTITIONS:
EXTERIOR:
0 ?
0 ?
0 ?
0 ?
FLOOR CONSTRUCTION:
(INCLUDING SUPPORTING BEAMS AND JOISTS)
ROOF CONSTRUCTION:
(INCLUDING SUPPORTING BEAMS AND JOISTS)
FIRE SEPARATIONS:
SHAFT ENCLOSURES:
(IBC SECTION 713)
RATING (HRS) REMARKS
PARTITIONS & PENETRATIONS:
FIRE BARRIERS AND FIRE PARTITIONS:
(IBC TABLE 707.3.10)
FIRE PARTITIONS AND TENANT SEPARATION:
(IBC SECTION 708)
EXITS:
1 ?
2 N/A
1 ?
0 SPRINKLER SYSTEM
1 ?
HORIZONTAL EXIT:
(IBC SECTION 1026)
CORRIDORS:
(IBC TABLE 1020.0)
2 N/A
EXIT PASSAGEWAY:
(IBC SECTION 1024)
(IBC TABLE 601, LSC TABLE A.8.2.1.2)
INTERIOR: 0 ?
NON-BEARING PARTITIONS:
EXTERIOR: 0 ?
INTERIOR: 0 ?
INCIDENTAL USE:
STORAGE:
(IBC SECTION 509)
RATING (HRS) REMARKS
ELEVATOR MACHINE ROOM:
(IBC SECTION 3005)
(IBC TABLE 509)
0 ?
1 ?
ELECTRICAL:
(NFPA 70)
0 ?
MECHANICAL:
(IBC SECTION 509)
1 SPRINKLER SYSTEM
MIXED OCCUPANCY SEPARATION:
(IBC TABLE 508.4) FULLY SPRINKLERED BUILDING)
A, E
A, E B S-2 REMARKS
B
S-2
- 1 -
1 - 1
- 1 -
PER 508.2.4 NO SEPARATION BETWEEN ACCESSORY
OCCUPANCIES AND MAIN OCCUPANCY IS REQUIRED.
NOTE IF YOUR PROJECT IS NOT SPRINKLERED- MODIFY TABLE
ALSO ADD OCCUPANCIES AS NEEDED
PER 508.2.4 NO SEPARATION BETWEEN ACCESSORY
OCCUPANCIES AND MAIN OCCUPANCY IS REQUIRED.
PER 508.2.4 NO SEPARATION BETWEEN ACCESSORY
OCCUPANCIES AND MAIN OCCUPANCY IS REQUIRED.
CODE REFERENCE GUIDE
AREA
MEANS OF EGRESS
BUILDING CONSTRUCTION TYPES INCLUDING
ALLOWABLE HEIGHT, ALLOWABLE BUILDING AREAS,
AND THE REQUIREMENTS FOR SPRINKLER
PROTECTION RELATED TO MINIMUM BUILDING
CONSTRUCTION TYPES.
LSC
STANDPIPES
INTERIOR FINISH
STATE OF GEORGIA MINIMUM FIRE SAFETY STANDARDS 120-3-3; TABLE 102.10:
PRIMARY SUPPLEMENT
OCCUPANCY CLASSIFICATION
NONE
IBC LSC
LSC IBC
IBC NONE
LSC NONE
HVAC SYSTEMS IMC
VERTICAL OPENINGS
SPRINKLER SYSTEMS MINIMUM CONSTRUCTION
STANDARD
NONE
LSC NONE
LSC NONE
FIRE ALARM SYSTEMS LSC NONE
SMOKE ALARMS AND SMOKE DETECTION SYSTEMS STATE STATUTE AND LSC NONE
PORTABLE FIRE EXTINGUISHERS IFC NONE
COOKING EQUIPMENT LSC AND NFPA 96 NONE
FUEL FIRED APPLIANCES IFGC NFPA 54
LIQUID PETROLEUM GAS NFPA 58 NFPA 54 OR IFGC
COMPRESSED NATURAL GAS NFPA 52 NONE
191 Peachtree Street NE Suite 2400
Atlanta, GA 30303-1770
(404) 237-2000 coopercarry.com
Principal-in-Charge
Project Manager
Project Architect
Staff Architect
Project No.
Date
Drawing No.
A
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
B C
D E
F G
H J
K L
M N
P
A B
C D
E F
G H
J K
L M
N P
© 2026 COOPER CARRY
ISSUED FOR CONSTRUCTION
GA DEPT OF EDUCATION DATA
FACILITY CODE: 628-1605-1320.01
FTE FOR THIS SITE: 2100
INSTRUCTIONAL UNITS: 108 (96 EXISTING,
22 NEW)
A u to d e s k D o c s /2
W o o d s to c k H
S
C T
A E l a b s /W
O O
D S
T O
C K
H S
C
T A
E L
A B
S V
.r v t
/1
/2
:0
:1
P
M
G0.02
04/02/2026
20260084PRINCIPAL-IN-CHARGE
BRIAN MITCHELL
CLAIRE COUVILLON
GENERAL INFORMATION
WOODSTOCK HS CTAE RMA
2010 TOWNE LAKE HILLS S. DR.
WOODSTOCK, GA 30189
CHEROKEE COUNTY SCHOOL SYSTEM
P R
O
JE
C T
N U
M B
E R
: 2
P
R O
JE
C
T N
A M
E : W
O O
D S
TO
C
K H
S C
TA
E
R M
A S
H E
E T
N U
M B
E R
: G 0.
G E
N E
R A
L
IN
FO
R
M A
TI
O
N
ISSUANCES
0' - 3"
COMMON PATH
0' - 3"
DEAD END
0' - 3"
0' - 3"
MAX. DIAGONAL
0' - 3"
EXIT SEPARATION
MEANS OF EGRESS LEGEND
COMMON PATH OF TRAVEL
(XX FT. MAX)
DISTANCES
DEAD END CORRIDOR
(XX FT. MAX)
TRAVEL DISTANCE
MAX DIAGONAL DISTANCE
EXIT SEPARATION
1 HOUR SEPARATION ASSEMBLY
OR FIRE PARTITION
PARTITION RATINGS
2 HOUR SEPARATION ASSEMBLY
OR FIRE PARTITION
3 HOUR SEPARATION ASSEMBLY
OR FIRE PARTITION
4 HOUR SEPARATION ASSEMBLY
OR FIRE PARTITION
O HOUR RATING
SMOKE SEPARATION ASSEMBLY
OCCUPANCY AREA LABELS
AREA NAME
150 SF
LEVEL EXIT LOAD / CAPACITY
EXIT CAPACITY
OCCUPANT LOAD
LEVEL EXIT LOAD / CAPACITY
@ DOORWAY
EXIT CAPACITY =
(DOOR WIDTH - REDUCTION TO ACHIEVE CLEAR OPENING) X LOAD
FACTOR
LEVEL EXIT LOAD / CAPACITY
@ CORRIDOR
EXIT CAPACITY =
CLEAR OPENING X LOAD
FACTOR
* REFERENCE "MEASUREMENT OF MEANS OF EGRESS" UNDER STAIR EXIT
CAPACITY
CLEAR EXIT
WIDTH
EXIT CAPACITY
OCCUPANT
LOAD
STAIR EXIT LOAD / CAPACITY
MEASUREMENT OF MEANS OF EGRESS: THE WIDTH OF MEANS OF EGRESS SHALL BE MEASURED IN THE CLEAR AT THE NARROWEST POINT OF THE EGRESS COMPONENT UNDER CONSIDERATION. PROJECTIONS WITHIN THE MEANS OF EGRESS OF NOT MORE THAN 4 1/2" IN STAIR (4" OTHERWISE) ON EACH SIDE SHALL BE PERMITTED AT
A HEIGHT OF 38" AND BELOW.
CLEAR EXIT WIDTH: FACE
OF PARTITION TO FACE OF
GUARD
38" HIGH X 4.5" WIDE
ALLOWABLE PROJECTION
AREA ON EACH SIDE
42" HIGH GUARD RAIL
34" HIGH HANDRAIL: LOCATED
WITHIN PROJECTION AREA
RAISED STRINGER:
LOCATED WITHIN
PROJECTION AREA
STAIR EXIT LOAD / CAPACITY
SMOKE BARRIER
"B" MODIFIER
INFORMATION TECHNOLGY LAB
(CYBERSECURITY)
FLIGHT OPERATIONS LAB
ENGINEERING LAB
703.1
RADIO STUDIO
703.2
CONTROL ROOM
703.4
TV STUDIO
703D
IDF
703C
ELEC.
703A
OFFICE
703B
STOR.
705B
STOR.
705A
OFFICE
703F
JAN.
703G
IDF
209' - 9 5/8"
136' - 9 3/8"
191 Peachtree Street NE Suite 2400
Atlanta, GA 30303-1770
(404) 237-2000 coopercarry.com
Principal-in-Charge
Project Manager
Project Architect
Staff Architect
Project No.
Date
Drawing No.
A
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
B C
D E
F G
H J
K L
M N
P
A B
C D
E F
G H
J K
L M
N P
© 2026 COOPER CARRY
ISSUED FOR CONSTRUCTION
GA DEPT OF EDUCATION DATA
FACILITY CODE: 628-1605-1320.01
FTE FOR THIS SITE: 2100
INSTRUCTIONAL UNITS: 108 (96 EXISTING,
22 NEW)
A u to d e s k D o c s /2
W o o d s to c k H
S
C T
A E l a b s /W
O O
D S
T O
C K
H S
C
T A
E L
A B
S V
.r v t
/1
/2
:0
:3
P
M
G1.01
04/02/2026
20260084SOPHIA TARKHAN
BRIAN MITCHELL
CLAIRE COUVILLON
MEANS OF EGRESS PLAN
WOODSTOCK HS CTAE RMA
2010 TOWNE LAKE HILLS S. DR.
WOODSTOCK, GA 30189
CHEROKEE COUNTY SCHOOL SYSTEM
P R
O
JE
C T
N U
M B
E R
: 2
P
R O
JE
C
T N
A M
E : W
O O
D S
TO
C
K H
S C
TA
E
R M
A S
H E
E T
N U
M B
E R
: G 1.
M E
A N
S O
F E
G R
E S
S P
LA
N
SCALE: 1/8" = 1'-0"G1.01
1 LEVEL 1 - MEANS OF EGRESS PLAN
NOTE: MEANS OF EGRESS DISTANCES UNCHANGED FROM ORIGINAL PLAN.
ISSUANCES
SCOPE OF WORK
191 Peachtree Street NE Suite 2400
Atlanta, GA 30303-1770
(404) 237-2000 coopercarry.com
Principal-in-Charge
Project Manager
Project Architect
Staff Architect
Project No.
Date
Drawing No.
A
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
B C
D E
F G
H J
K L
M N
P
A B
C D
E F
G H
J K
L M
N P
© 2026 COOPER CARRY
ISSUED FOR CONSTRUCTION
GA DEPT OF EDUCATION DATA
FACILITY CODE: 628-1605-1320.01
FTE FOR THIS SITE: 2100
INSTRUCTIONAL UNITS: 108 (96 EXISTING,
22 NEW)
A u to d e s k D o c s /2
W o o d s to c k H
S
C T
A E l a b s /W
O O
D S
T O
C K
H S
C
T A
E L
A B
S V
.r v t
/1
/2
:0
:1
P
M
A0.1
04/02/2026
20260084SOPHIA TARKHAN
BRIAN MITCHELL
CLAIRE COUVILLON
OVERALL FLOOR PLAN - HIGH
SCHOOL
WOODSTOCK HS CTAE RMA
2010 TOWNE LAKE HILLS S. DR.
WOODSTOCK, GA 30189
CHEROKEE COUNTY SCHOOL SYSTEM
P R
O
JE
C T
N U
M B
E R
: 2
P
R O
JE
C
T N
A M
E : W
O O
D S
TO
C
K H
S C
TA
E
R M
A S
H E
E T
N U
M B
E R
: A 0.
O V
E R
A
LL
F
LO
O R
P
LA
N
H
IG
H S
C H
O O
L
SCALE: 1" = 30'-0"A0.1
1 FLOOR PLAN - OVERALL
EXISTING WALL TO BE
REMOVED (TYP.)
EXISTING WALL, DOOR
& FRAME TO BE
REMOVED.
EXISTING RISERS TO BE
REMOVED. PATCH FLOOR
AND PREPARE FOR NEW
FLOORING AND BASE.
ENGINEERING LAB
REMOVE ALL FLOORING, BASE, PLUMBING FIXTURES,
CEILINGS AND LIGHTS, AS INDICATED WITHIN THIS AREA.
COORDINATE REMOVAL AND/OR RELOCATION OF
FURNITURE WITH OWNER.
REMOVE EXISTING
FLOORING AND BASE. PATCH
FLOOR AND PREPARE FOR
NEW FLOORING AND BASE.
EXISTING WALL TO BE
REMOVED (TYP.)
EXISTING WALL TO BE
REMOVED (TYP.)
REMOVE EXISTING FLOORING
AND BASE. PATCH FLOOR
AND PREPARE FOR NEW
FLOORING AND BASE.
EXISTING CASEWORK TO BE
REMOVED. REMOVE AND
CAP ALL PLUMBING BELOW
SLAB OR ABOVE CEILING
REMOVE PLUMBING AND
ACCESSORIES. CAP ALL PLUMBING
BELOW SLAB OR ABOVE CEILING
EXISTING WALL TO BE
REMOVED (TYP.)
GENERAL NOTES DEMOLITION
PLANS
1. REMOVE ALL FLOORING, GLUE AND WALL BASE WHERE FLOORS ARE
TO BE REMOVED. PATCH AND LEVEL FLOOR AS NECESSARY.
2. CLEAN ALL WALLS AND REMOVE ADHESIVES AND PAINT RIDGES AT
BASE LINE BEFORE RE-PAINTING WALLS.
3. WHERE WALLS ARE REMOVED, PATCH WALLS AND FLOOR SLAB AND
PREP FOR NEW FINISHES.
4. PATCH WALL WHERE WALL ANGLE REMOVED AND PREP FOR NEW
FINISH.
191 Peachtree Street NE Suite 2400
Atlanta, GA 30303-1770
(404) 237-2000 coopercarry.com
Principal-in-Charge
Project Manager
Project Architect
Staff Architect
Project No.
Date
Drawing No.
A
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
B C
D E
F G
H J
K L
M N
P
A B
C D
E F
G H
J K
L M
N P
© 2026 COOPER CARRY
ISSUED FOR CONSTRUCTION
GA DEPT OF EDUCATION DATA
FACILITY CODE: 628-1605-1320.01
FTE FOR THIS SITE: 2100
INSTRUCTIONAL UNITS: 108 (96 EXISTING,
22 NEW)
A u to d e s k D o c s /2
W o o d s to c k H
S
C T
A E l a b s /W
O O
D S
T O
C K
H S
C
T A
E L
A B
S V
.r v t
/1
/2
:0
:5
P
M
A1.00
04/02/2026
20260084SOPHIA TARKHAN
BRIAN MITCHELL
CLAIRE COUVILLON
DEMOLITION FLOOR PLAN
WOODSTOCK HS CTAE RMA
2010 TOWNE LAKE HILLS S. DR.
WOODSTOCK, GA 30189
CHEROKEE COUNTY SCHOOL SYSTEM
P R
O
JE
C T
N U
M B
E R
: 2
P
R O
JE
C
T N
A M
E : W
O O
D S
TO
C
K H
S C
TA
E
R M
A S
H E
E T
N U
M B
E R
: A 1.
D E
M O
LI
TI
O N
F
LO
O R
P
LA
N
SCALE: 1/8" = 1'-0"A1.00
1 FLOOR PLAN - DEMOLITION
ISSUANCES
2,585 SF
FLIGHT OPERATIONS LAB
1,306 SF
INFORMATION TECHNOLGY LAB
(CYBERSECURITY)
93 SF
703A
OFFICE
93 SF
703B
STOR.
99 SF
705B
STOR.
77 SF
705A
OFFICE
56 SF
703C
ELEC.
52 SF
703D
IDF
703.4703.3703.2703.1
705.4 703
705.1
705.3
705.2
703.5
MB1 MB1IB
MB1
IB
MB1
0M060
1M060
0M060
0M060
W1
1M060
A3.11
A3.11
Sim
A3.11
A3.11
A3.11
ENGINEERING LAB
A3.11
FLIGHT OPERATIONS LAB
INFORMATION TECHNOLGY LAB
(CYBERSECURITY)
703A
OFFICE
703B
STOR.
705B
STOR.
705A
OFFICE
7' - 0"
± 1 4'
- 8 3/
0"
8' - 0"
7'
0"
703F
JAN.
703G
IDF
703D
IDF
703C
ELEC.
191 Peachtree Street NE Suite 2400
Atlanta, GA 30303-1770
(404) 237-2000 coopercarry.com
Principal-in-Charge
Project Manager
Project Architect
Staff Architect
Project No.
Date
Drawing No.
A
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
B C
D E
F G
H J
K L
M N
P
A B
C D
E F
G H
J K
L M
N P
© 2026 COOPER CARRY
ISSUED FOR CONSTRUCTION
GA DEPT OF EDUCATION DATA
FACILITY CODE: 628-1605-1320.01
FTE FOR THIS SITE: 2100
INSTRUCTIONAL UNITS: 108 (96 EXISTING,
22 NEW)
A u to d e s k D o c s /2
W o o d s to c k H
S
C T
A E l a b s /W
O O
D S
T O
C K
H S
C
T A
E L
A B
S V
.r v t
/1
/2
:0
:4
P
M
A1.11
04/02/2026
20260084SOPHIA TARKHAN
BRIAN MITCHELL
CLAIRE COUVILLON
PROPOSED & DIMENSIONED
FLOOR PLANS
WOODSTOCK HS CTAE RMA
2010 TOWNE LAKE HILLS S. DR.
WOODSTOCK, GA 30189
CHEROKEE COUNTY SCHOOL SYSTEM
P R
O
JE
C T
N U
M B
E R
: 2
P
R O
JE
C
T N
A M
E : W
O O
D S
TO
C
K H
S C
TA
E
R M
A S
H E
E T
N U
M B
E R
: A 1.
P R
O P
O S
E D
D
IM
E
N S
IO
N
E D
F
LO
O R
P
LA
N S
SCALE: 1/8" = 1'-0"A1.11
1 FLOOR PLAN - PROPOSED
SCALE: 1/8" = 1'-0"A1.11
2 FLOOR PLAN - DIMENSIONED
ISSUANCES
W:
B:
F:
B-1
LVT-1
P-1
W:
B:
F:
B-1
LVT-1
P-1
INFORMATION TECHNOLGY LAB
(CYBERSECURITY)705
FLIGHT OPERATIONS LAB
W:
B:
F:
B-1
LVT-1
ETR
ENGINEERING LAB
703.1
RADIO STUDIO
703.2
CONTROL ROOM
703.4
TV STUDIO
W:
B:
F:
B-1
LVT-1
ETR W:
B:
F:
B-1
LVT-1
ETR W:
B:
F:
B-1
LVT-1
ETR
703.5
Room
703.6
Room
W:
B:
F:
B-1
LVT-1
ETR
W:
B:
F:
B-1
LVT-1
ETR
703D
IDF
703C
ELEC.703A
OFFICE
703B
STOR.
703G
IDF
W:
B:
F:
B-1
LVT-1
P-1
W:
B:
F:
B-1
LVT-1
P-1
W:
B:
F:
B-1
LVT-1
P-1W:
B:
F:
B-1
LVT-1
P-1
W:
B:
F:
B-1
LVT-1
P-1W:
B:
F:
B-1
LVT-1
P-1
FINISH SCHEDULE
CODE
ACT-1
DESCRIPTION
ACOUSTICAL CEILING PANEL
MANUFACTURER
ARMSTRONG
PRODUCT NAME MODEL/SIZE FINISH/COLOR
CORTEGA #770 - 24"X24", 15/16" SQUARE LAY-IN WHITE
ACOUSTICAL CEILING PANEL
LVT-1 LUXURY VINYL TILE INTERFACE CLIFF 3.0MM 25CM X 1M X 3.0MM ALABASTER - C00801
LUXURY VINYL TILE
P-1 TYPICAL WALL PAINT THROUGHOUT SHERWIN WILLIAMS CUSTOM CHEROKEE BEIGE TYPICAL WALL PAINT
PAINT
P-2 SOFFITS SHERWIN WILLIAMS SW7006 EXTRA WHITE NEW GYP. BD. SOFFITS
B-1 RUBBER BASE ROPPE PINNACLE RUBBER BASE STANDARD TOE 193 - BLACK BROWN
RUBBER BASE
191 Peachtree Street NE Suite 2400
Atlanta, GA 30303-1770
(404) 237-2000 coopercarry.com
Principal-in-Charge
Project Manager
Project Architect
Staff Architect
Project No.
Date
Drawing No.
A
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
B C
D E
F G
H J
K L
M N
P
A B
C D
E F
G H
J K
L M
N P
© 2026 COOPER CARRY
ISSUED FOR CONSTRUCTION
GA DEPT OF EDUCATION DATA
FACILITY CODE: 628-1605-1320.01
FTE FOR THIS SITE: 2100
INSTRUCTIONAL UNITS: 108 (96 EXISTING,
22 NEW)
A u to d e s k D o c s /2
W o o d s to c k H
S
C T
A E l a b s /W
O O
D S
T O
C K
H S
C
T A
E L
A B
S V
.r v t
/1
/2
:0
:0
P
M
A1.12
04/02/2026
20260084SOPHIA TARKHAN
BRIAN MITCHELL
CLAIRE COUVILLON
FINISH PLAN & SCHEDULE
WOODSTOCK HS CTAE RMA
2010 TOWNE LAKE HILLS S. DR.
WOODSTOCK, GA 30189
CHEROKEE COUNTY SCHOOL SYSTEM
P R
O
JE
C T
N U
M B
E R
: 2
P
R O
JE
C
T N
A M
E : W
O O
D S
TO
C
K H
S C
TA
E
R M
A S
H E
E T
N U
M B
E R
: A 1.
F
IN
IS
H
P
LA
N
S C
H E
D U
LE
SCALE: 1/8" = 1'-0"A1.12
1 FLOOR PLAN - FINISHES
ISSUANCES
EXISTING GYP. BE CEILING
TO BE REMOVED.
A2.10
9' - 0" ACT-1 10' - 0" ACT-1
8' - 8" ACT-1
8' - 8" ACT-1
INFORMATION TECHNOLGY LAB
(CYBERSECURITY)
703A
OFFICE
703B
STOR.
703C
ELEC.
703D
IDF
FLIGHT OPERATIONS LAB
FLIGHT OPERATIONS LAB
705B
STOR.
705A
OFFICE
8' - 8" ACT-1
9' - 0" ACT-1
5/8" GYP. BD. OVER 3 5/8"
MTL STUDS @ 24: O.C.
ACOUSTIC CEILING
SYSTEM
PRE-FORMED CORNER
BEAD (TYP.)
4"
EXTEND GYP. BD. 6" BEYOND
CEILING HEIGHT (TYP.)
RCP DEMO NOTES
1. REMOVE ALL EXISTING CEILING TILES AND GRID, INCLUDING WALL
ANGLE.
2. REMOVE ALL LIGHT FIXTURES.
3. SECURE ALL INTERCOM, WI-FI ROUTERS AND OTHER LOW VOLTAGE
DEVICES TO STRUCTURE. SAVE FOR REINSTALLATION IN NEW CEILING
SYSTEM. COORDINATE REINSTALLATION WITH OWNER.
4. SEE MECHANICAL PLANS FOR RE-USE OF EXISTING DUCTWORK. ALL
DUCTWORK TO REMAIN TO BE CLEANED.
5. AVOID DAMAGE TO SPRINKLER SYSTEM AND ADJUST TO WORK WITH
NEW CEILING LAYOUT.
6. WHERE GYP. BD. SOFFITS HAVE BEEN REMOVED PATCH CEILING GRID
TO MATCH EXIST.
RCP NOTES
1. INSTALL NEW CEILING TILES & GRID AS SHOWN.
2. INSTALL NEW LIGHT FIXTURES AS SHOWN. COORDINATE WITH
ELECTRICAL.
3. RE-INSTALL LOW VOLTAGE DEVICES AS INDICATED ON ELECTRICAL
SYSTEMS PLAN. COORDINATE WITH OWNER.
4. CENTER SPRINKLER HEADS ON CEILING TILE.
RCP LEGEND
LIGHT FIXTURES
RECESSED CEILING FIXTURE - LINEAR
2x2 LAY-IN FIXTURE, PARABOLIC LENS
2x2 LAY-IN FIXTURE, ACRYLIC LENS
STRIP FLUORESCENT FIXTURE
TRACK LIGHTING
PARTITION MOUNTED FIXTURE, SCONCE
PARTITION MOUNTED FIXTURE, LINEAR
MECHANICAL FIXTURES
ACCESS PANEL
RETURN AIR DIFFUSER
SUPPLY AIR DIFFUSER
LINEAR SLOT DIFFUSER
POLE MOUNTED LIGHT FIXTURE
POLE MOUNTED LIGHT FIXTURE
EXIST SIGN CEILING MOUNTED
EXIT SIGN PARTITION MOUNTED
2x2 EMERGENCY FIXTURE, ACRYLIC LENS
2x2 EMERGENCY FIXTURE, PARABOLIC LENS
191 Peachtree Street NE Suite 2400
Atlanta, GA 30303-1770
(404) 237-2000 coopercarry.com
Principal-in-Charge
Project Manager
Project Architect
Staff Architect
Project No.
Date
Drawing No.
A
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
B C
D E
F G
H J
K L
M N
P
A B
C D
E F
G H
J K
L M
N P
© 2026 COOPER CARRY
ISSUED FOR CONSTRUCTION
GA DEPT OF EDUCATION DATA
FACILITY CODE: 628-1605-1320.01
FTE FOR THIS SITE: 2100
INSTRUCTIONAL UNITS: 108 (96 EXISTING,
22 NEW)
A u to d e s k D o c s /2
W o o d s to c k H
S
C T
A E l a b s /W
O O
D S
T O
C K
H S
C
T A
E L
A B
S V
.r v t
/1
/2
:0
:2
P
M
A2.10
04/02/2026
20260084SOPHIA TARKHAN
BRIAN MITCHELL
CLAIRE COUVILLON
REFLECTED CEILING PLANS
WOODSTOCK HS CTAE RMA
2010 TOWNE LAKE HILLS S. DR.
WOODSTOCK, GA 30189
CHEROKEE COUNTY SCHOOL SYSTEM
P R
O
JE
C T
N U
M B
E R
: 2
P
R O
JE
C
T N
A M
E : W
O O
D S
TO
C
K H
S C
TA
E
R M
A S
H E
E T
N U
M B
E R
: A 2.
R E
FL
E
C
TE
D C
E
IL
IN
G
P
LA
N S
SCALE: 1/8" = 1'-0"A2.10
1 REFLECTED CEILING PLAN - DEMOLITION
SCALE: 1/8" = 1'-0"A2.10
2 REFLECTED CEILING PLAN - NEW WORK
SCALE: 1 1/2" = 1'-0"A2.10
3 Section 1
ISSUANCES
ALUM. CLOSURE TO
MATCH EXIST.
STOREFRONT (TYP.)
EXIST. STOREFRONT TO
REMAIN. REMOVE ALL OLD
CAULKING AND MASONRY
FROM FRAMES.
MB1 IB MB1
TTTT
T T T T
T T T T
T T T T
T
TT
TT
T
TT
T
T T T T T
T
T
T
T
T
705.2
705.3
705.1
705.4
FLIGHT OPERATIONS LAB
705B
STOR.
705A
OFFICE
703F
JAN.
703G
IDF
TT
T
T
T T
T
T
T
TT TT
T
T T
T
T
T T
T
MB1
IB
MB1
703.5
703.4703.3703.2
703.1
703D
IDF
703C
ELEC.
703A
OFFICE
703B
STOR.
INFORMATION TECHNOLGY LAB
(CYBERSECURITY)
EXIST. CASEWORK
TO REMAIN
EQUIPMENT LEGEND
MB
TY
P
E M
A R
K
E Q
U
IP
M E
N T
N A
M E
C O
N
TR
A C
TO
R
O W
N E
R P
R O
V
ID
E D
A
N D
IN
S
TA
LL
E D
MARKER BOARD ●
IB ACTIVE PANEL BOARD ●
T TABLE ●
1 5/8" MTL. STUD SECURE
TO COLUMN (TYP.)
5/8" GYP. BD.
EXIST. COLUMN
TO REMAIN
1/ 2"
T Y
P
PRE-FORMED CORNER
BEAD (TYP.)
1 5/8" MTL. STUD SECURE
TO COLUMN (TYP.)
5/8" GYP. BD.
EXIST. COLUMN
TO REMAIN
1/ 2"
PRE-FORMED CORNER
BEAD (TYP.)
3 5/8" MTL. STUD
SECURE TO WALL
191 Peachtree Street NE Suite 2400
Atlanta, GA 30303-1770
(404) 237-2000 coopercarry.com
Principal-in-Charge
Project Manager
Project Architect
Staff Architect
Project No.
Date
Drawing No.
A
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
B C
D E
F G
H J
K L
M N
P
A B
C D
E F
G H
J K
L M
N P
© 2026 COOPER CARRY
ISSUED FOR CONSTRUCTION
GA DEPT OF EDUCATION DATA
FACILITY CODE: 628-1605-1320.01
FTE FOR THIS SITE: 2100
INSTRUCTIONAL UNITS: 108 (96 EXISTING,
22 NEW)
A u to d e s k D o c s /2
W o o d s to c k H
S
C T
A E l a b s /W
O O
D S
T O
C K
H S
C
T A
E L
A B
S V
.r v t
/1
/2
:0
:5
P
M
A3.11
04/02/2026
20260084SOPHIA TARKHAN
BRIAN MITCHELL
CLAIRE COUVILLON
ENLARGED PLANS & DETAILS
WOODSTOCK HS CTAE RMA
2010 TOWNE LAKE HILLS S. DR.
WOODSTOCK, GA 30189
CHEROKEE COUNTY SCHOOL SYSTEM
P R
O
JE
C T
N U
M B
E R
: 2
P
R O
JE
C
T N
A M
E : W
O O
D S
TO
C
K H
S C
TA
E
R M
A S
H E
E T
N U
M B
E R
: A 3.
E N
LA
R
G E
D P
LA
N
S
D E
TA
IL
S
SCALE: 3" = 1'-0"A3.11
3 PLAN SECTION - WINDOW CLOSURE PLATE
SCALE: 1/4" = 1'-0"A3.11
1 ENLARGED PLAN - FLIGHT OPERATIONS
SCALE: 1/4" = 1'-0"A3.11
2 ENLARGED PLAN - CYBERSECURITY
SCALE: 3" = 1'-0"A3.11
4 PLAN SECTION - TYPICAL EXISTING COLUMN WRAP
SCALE: 1 1/2" = 1'-0"A3.11
5 PLAN SECTION - EXISTING COLUMN WRAP
ISSUANCES
GENERAL NOTES
1. LIMITING HEIGHT, STUD GAUGE AND SPACING INFORMATION PROVIDED IN PARTITION SCHEDULES ARE ABBREVIATED AND MAY NOT ADDRESS ALL CONDITIONS OF THE PROJECT. THIS INFORMATION IS PROVIDED FOR USE AS A GUIDE AND DOES NOT ALLEVIATE THE CONTRACTOR FROM PROVIDING PARTITION ASSEMBLIES THAT MEET THE DESIGN CRITERIA FOR EACH CONDITION. CONTRACTOR SHALL COORDINATE WITH PROJECT CONDITIONS AND PROVIDE PARTITION ASSEMBLIES BASED ON MANUFACTURER'S STANDARD SPAN TABLES THAT MEET DESIGN CRITERIA INCLUDING: LOADS, DEFLECTION LIMITS, FIRE TEST RATINGS AND SOUND TEST
CLASSIFICATIONS.
2. SOUND TRANSMISSION CLASS (STC) INDICATED IS BASED ON MATERIALS AND CONSTRUCTION IDENTICAL TO THOSE IN SOUND TEST ASSEMBLY SCHEDULED. IF CHANGES IN THE ASSEMBLY ARE NECESSARY DUE TO CONTRACTOR'S SELECTION OF PRODUCTS / MANUFACTURER OR DUE TO REQUIRED PARTITION HEIGHT, DEFLECTION CRITERIA OR DESIGN PRESSURE, CONTRACTOR SHALL SUBMIT FOR APPROVAL AND PROVIDE ALTERNATE PARTITION ASSEMBLIES THAT MEET SPECIFIED DESIGN CRITERIA. FIELD SOUND TRANSMISSION (FSTC) IS PERMITTED TO BE 5 POINTS LOWER THAN SPECIFIED STC. REFER TO LEGEND BELOW FOR
ABBREVIATIONS.
3. IF THE SELECTED STEEL STUD MANUFACTURER'S THICKNESS OF STEEL COMPONENT VARIES FROM THE BASIS OF DESIGN (AS DEFINED BELOW) OR HAS OTHER ATTRIBUTES THAT VARY FROM THE BASIS OF DESIGN, PROVIDE MANUFACTURER'S STANDARD THICKNESS WITH LIMITING HEIGHT SPAN TABLES THAT MEETS OR
EXCEEDS THE SPECIFIED DESIGN CRITERIA.
4. PARTITIONS SHALL EXTEND TO AND TERMINATE AT THE UNDERSIDE OF STRUCTURE ABOVE, UNLESS NOTED
OTHERWISE.
5. RATED PARTITIONS SHALL BE PERMANENTLY IDENTIFIED IN CONCEALED SPACES EITHER AS REQUIRED BY CODE OR WITH 2" HIGH LETTERING IN A COLOR / VALUE CONTRASTING WITH THE BACKGROUND AND SPACE NO MORE THAN 12 FEET ON CENTER. TEXT SHALL READ AS REQUIRED BY CODE OFFICIAL OR AS "_____ HOUR FIRE & SMOKE BARRIER - PROTECT ALL OPENINGS." (FILL IN APPROPRIATE HOURLY RATING)
6. GYP. BD. IS TO BE TYPE 'X' FIRE RESISTANT BOARD UNLESS OTHERWISE NOTED.
7. DOOR OPENING FRAMING (WHETHER RATED OR NON-RATED) SHALL BE MINIMUM 20 GAGE STUDS WITH SINGLE STUD JAMB FOR STANDARD WEIGHT DOORS AND DOUBLE STUD JAMB FOR HEAVY WEIGHT DOORS IN
ACCORDANCE WITH GYPSUM ASSOCIATION STANDARD GA-219.
DESIGN CRITERIA
STEEL STUD PARTITIONS
DESIGN PRESSURE PARTITION PURPOSE / LOCATION
5 / 7.5 / 10 / 15 PSF ELEVATOR HOIST WAYS BASED ON ELEVATOR VELOCITY
(REFERENCE USG RECOMMENDATIONS BELOW)
10 PSF STAIRS, OTHER VERTICAL SHAFTS
10 / 15 PSF GROUND FLOOR LOBBIES & ATRIUMS
5 PSF OTHER PARTITIONS
DEFLECTION LIMIT CLADDING MATERIAL
L/720 BRICK / STONE CLADDING
L/360 LATH AND PLASTER OR VENEER PLASTER
L/360 TILE FINISH
L/240 OTHER
USG HOIST WAY CHART - PROVIDED FOR REFERENCE ONLY
USG RECOMMENDS DESIGN PRESSURES FOR SHAFT PARTITION CONSTRUCTION IN ACCORDANCE WITH THE
FOLLOWING TABLE:
ELEVATOR VELOCITY; FPM ONE OR TWO ELEVATORS PER
SHAFT
THREE OR MORE ELEVATORS
PER SHAFT
0 TO 180
180 TO 1000
1000 TO 1600
1800 TO 2000
5.0 PSF
7.5 PSF
10.0 PSF
15.0 PSF
5.0 PSF
5.0 PSF
7.5 PSF
5.0 PSF
BASIS OF DESIGN
MINIMUM METAL THICKNESS
IF THE SELECTED MANUFACTURER'S THICKNESS OF STEEL COMPONENTS VARIES FROM THE BASIS OF DESIGN INDICATED BELOW, PROVIDE MANUFACTURER'S STANDARD THICKNESS AND SPAN TABLES THAT MEETS OR
EXCEEDS THE PERFORMANCE REQUIREMENTS INDICATED.
STEEL FRAME PARTITIONS STEEL FRAME PARTITIONS ARE BASED ON INFORMATION PROVIDED IN THE
STEEL STUD MANUFACTURER'S ASSOCIATION (SSMA) PUBLICATION
"PRODUCT TECHNICAL INFORMATION" EFFECTIVE 8/14/15 AND COMPLIES
WITH 2009, 2012, AND 2015 IBC.
METAL THICKNESS - STEEL COMPONENTS
REFERENCE GAGE DESIGN THICKNESS (IN.) MINIMUM THICKNESS (MIL.)
20 - STRUCTURAL
20- DRYPARTITION
0.0188
0.0283
0.0346
0.0312
0.0451
SHAFT PARTITIONS SHAFT PARTITIONS ARE BASED ON UNITED STATES GYPSUM COMPANY
PRODUCT LITERATURE SA 926 / REV. 2-2017
METAL THICKNESS - STEEL COMPONENTS
REFERENCE GAGE DESIGN THICKNESS (IN.) MINIMUM THICKNESS (IN.)
0.0188
0.0283
0.0359
0.0179
0.0227
0.0341
CHASE PARTITIONS CHASE PARTITIONS ARE BASED ON UNITED STATES GYPSUM COMPANY
PRODUCT LITERATURE SA 923 / REV. 03/2002
METAL THICKNESS - STEEL COMPONENTS
REFERENCE GAGE DESIGN THICKNESS (IN.) MINIMUM THICKNESS (IN.)
0.0188
0.0284
0.0359
0.0478
0.0179
0.0270
0.0341
0.0454
PARTITION - INTERIOR
MAXIMUM SPACING - CONTROL JOINTS
CONSTRUCTION AND LOCATION MAXIMUM SINGLE DIMENSION MAXIMUM SINGLE AREA
30' - 0"
CEILING - INTERIOR
WITH PERIMETER RELIEF
WITHOUT PERIMETER RELIEF
50' - 0"
30' - 0"
2,500 S.F.
900 S.F.
NOTE: ANY REQUIRED CONTROL JOINTS NOT SHOWN OR LOCATED IN THE DRAWINGS SHALL BE FIELD
COORDINATED WITH THE ARCHITECT PRIOR TO FINAL INSTALLATION
GYP. BD. CONTROL JOINT PLACEMENT DIAGRAMS
STRUCTURE ABOVE
FINISHED CEILING
CONTROL JOINTS REFERENCE
CONTROL JOINT DETAILS FOR
INFORMATION
SCHEDULED FINISH FLOOR
SCHEDULED PARTITION BASE
GYP. BD. CONTROL JOINTS
HIGH SPEED ELEVATOR SHAFTS MAY REQUIRE SPECIAL DESIGN CONSIDERATION
"S" MODIFIER PARTITION INSULATION
INSULATION
ABBREVIATION
INSULATION TYPE
FB
MW
MB
FIBERGLASS BATT INSULATION (UNFACED) U.N.O.
MINERAL WOOL BLANKET INSULATION
MINERAL WOOL BOARD
NOTE: SOUND ATTENUATION BLANKET IS SPECIFIED IN 092900-GYP. BD., ALL OTHER INSULATION TYPES ARE
SPECIFIED IN 072100 THERMAL INSULATION
PARTITION NUMBERING SYSTEM
S0
W1
M2
X4
CORE STRUCTUREHOURLY RATING
F3
STEEL STUD
WOOD STUD
CONCRETE MASONRY UNIT
FURRING
SHAFT PARTITION - STEEL STUD
0 HOUR
1 HOUR
2 HOUR
3 HOUR
4 HOUR
SUBSTITUTE THE OUTSIDE FACE LAYER OF SCHEDULED GYP. BD. WITH IMPACT RESISTANT
GYP. BD. OF EQUAL THICKNESS AND FIRE RATING
C CHASE PARTITION
PARTITION TYPE MARKER
MODIFICATION CODES
MODIFICATION CODE(S)
OVERALL PARTITION THICKNESS
HOURLY RATING
CORE STRUCTURE
WS438S2
I
W
M
P
S
T
SUBSTITUTE SCHEDULED GYP. BD. WITH GLASS MAT, WATER RESISTANT BACKING PANEL
GYP. BD. OF EQUAL THICKNESS AND FIRE RATING IN AREAS TO RECEIVE TILE
PROVIDE CONTINUOUS STEEL SECURITY MESH ATTACHED TO FACE OF STUDS.
PARTIAL HEIGHT PARTITION - REFER TO "P" MODIFIER DETAIL
SOUND ATTENUATION REQUIRED -COMPLY WITH SCHEDULED STC
RATING & TESTING ASSEMBLY REQUIREMENTS- WHERE TESTING ASSEMBLY IS NOT NOTED
PROVIDE INSULATION TYPE AND THICKNESS NOTED ON PARTITION SCHEDULE.
REFER TO SPECIFICATIONS SECTION 092900 - GYPSUM BOARD.
EXTEND GYP. BD. TO ABOVE FINISH CEILING - REFER TO "T" MODIFIER DETAIL BELOW FOR
ADDITIONAL INFORMATION
X EXTEND PARTITION TO ABOVE FINISH CEILING AND BRACE TO STRUCTURE - REFER TO "X"
MODIFIER DETAIL BELOW FOR ADDITIONAL INFORMATION
Y EXTEND PARTITION TO UNDERSIDE OF FINISH CEILING, ADD SOUND ATTENUATION ABOVE
CEILING - REFER TO "Y" MODIFIER DETAIL BELOW FOR ADDITIONAL INFORMATION
L LEAD LINED PARTITIONS - REFER TO "L" MODIFIER PARTITION DETAILS.
SMOKE BARRIER- PROVIDE CONTINUOUS SMOKE BARRIER AS DEFINED BY CODE IN
PARTITION TYPE NOTED
B
3/4"
1/2" MAX.
CONTROL JOINT ACCESSORY (MUD IN)
(2) 5/8" LAYERS OF TYPE X GYP. BD. STRIPS
FASTENED TO STUD
WOOD STUD FRAMING
1 LAYER OF TYPE 'X GYP. BD. 1 HR,
2 LAYERS OF TYPE 'X' GYP. BD. FOR 2 HR.;
REFER TO SCHEDULED PARTITION FOR
ADDITIONAL INFORMATION
STEEL STUD FRAMING
CONTROL JOINT ACCESSORY (MUD IN)SOUND INSULATION TO FILL OPENING
1/2" MAX.
GYPSUM BOARD; SEE PARTITION TYPE
FOR ADDITIONAL INFO.
STEEL "J" RUNNER
CONTINUOUS FIRESTOP SEALANT
STRUCTURE ABOVE
AT VERTICAL ENCLOSURE,
1 LAYER 5/8" TYPE "X" GYP. BD., 1HR;
2 LAYERS 5/8" TYPE "X" GYP. BD., 2 HR
1" GYP. BD. LINER PANEL
ENCLOSED OBJECT (IF APPLICABLE)
AT HORIZONTAL ENCLOSURE,
2 LAYERS 5/8" TYPE "X" GYP. BD., 1 HR;
3 LAYERS 5/8" TYPE "X" GYP. BD., 2 HR
"CH" STUD
4' -0
" M A
X . H
E
IG
H T
MAX SPAN 11'-8" W/ 20 GA. STUDS
MAX. SPAN 8'-11" W/ 25 GA. STUDS
BASIS OF DESIGN: I.C.C. EVALUATION AER 09038
LOWER
PRIORITY
HIGHER PRIORITY.
MAINTAIN CONTINUITY
OF PARTITION WITH
HIGHER PRIORITY AT
INTERSECTIONS
PARTITION PRIORITY LEGEND
FOUR HOUR FIRE PARTITION
TWO HOUR FIRE AND SMOKE PARTITION
TWO HOUR FIRE PARTITION
1 HOUR FIRE AND SMOKE PARTITION
1 HOUR FIRE PARTITION
SMOKE PARTITION
NON-RATED PARTITION
PRIORITY 1 HIGHER
PRIORITY 2
PRIORITY 3
PRIORITY 4
PRIORITY 5
PRIORITY 6
PRIORITY 7 LOWER
HOLLOW METAL
FRAME
STEEL STUDS
JAMB STUDS AS REQ'D.
TAPE & JOINT COMP. TYP.
1 HOUR CONSTRUCTION
TWO HOUR CONSTRUCTION
HIGHER PRIORITY PARTITION
ONE LAYER AT 1
HOUR SMOKE
PARTITION
1 HOUR PARTITION
NON RATED PARTITION
6"
6" TYPICAL UNLESS NOTED OTHERWISE.
CHECK ALL DOORS FOR ADA CLEARANCE
BEFORE INSTALLATION OF FRAME.
HOLLOW METAL FRAME
5/8" EXTERIOR GLASS
MAT SHEATHING
EXT. PARTITION
MATERIAL AS
SCHEDULED
ACOUSTICAL SEALANT
CONT. RUNNER @
EXTERIOR PARTITION
STEEL STUDS
TAPE & JOINT
COMPOUND
NOTE: SEAL ANY
PENETRATIONS W/
ACOUSTICAL SEALANT
0M040 3 5/8" 8'-6"
OMNON-RATED CONCRETE MASONRY PARTITION
NON-LOAD BEARING
DESIGNATION
NO. FIRE
TEST
"S" MODIFIER
N/A
"A"
DIM.
LIMITING HEIGHT (NOTE 1)
5 PSF
REINF.
CMU
(NOTE 9) 2.67"
3.625"
3.625"
EQUIVALENT
THICKNESS
(NOTE 10)
DESIG -
NATION
STC CLASS
(NOTE 2 & 4)
WEIGHT
CLASS
(NOTE 7)
CELL FILL
MATERIAL
(NOTE 3)
S1
S2
S3
LIGHT
LIGHT
LIGHT
HOLLOW
GROUT
SAND
0M060 5 5/8" 13'-0"N/A (NOTE 9) 3.09"
5.625"
5.625"
S1
S2
S3
LIGHT
LIGHT
LIGHT
HOLLOW
GROUT
SAND
0M080 7 5/8" 17'-4"N/A (NOTE 9) 4.04"
7.625"
7.625"
S1
S2
S3
LIGHT
LIGHT
LIGHT
HOLLOW
GROUT
SAND
0M120 11 5/8" 26'-0"N/A (NOTE 9) 5.66"
11.625"
11.625"
S1
S2
S3
LIGHT
LIGHT
LIGHT
HOLLOW
GROUT
SAND
STRUCTURE ABOVE
FILL VOID WITH SOUND ATTENUATION INSULATION AND
CONTINUOUS ACOUSTICAL SEALANT EACH SIDE
CONCRETE UNIT MASONRY (CMU) WITH JOINT
REINFORCEMENT EVERY 2 COURSES
PLAN
BASE
HEAD
TOP OF STRUCTURAL SLAB
"A" OVERALL DIMENSION
BASE JOINT GROUTED SOLID
NOTES:
1) PARTITIONS TO RECEIVE BLOCK FILLER BEFORE PAINTING
WHERE SCHEDULED
2) 1" RADIUS BULLNOSE AT OUTSIDE CORNERS (TYP.)
UNGROUTED/PARTIALLY
GROUTED
FULLY GROUTED
10 PSF 15 PSF 5 PSF 10 PSF 15 PSF
9'-0"
12'-0"
18'-0"
10'-0""
15'-0"
13'-4"
20'-0""
26'-8"
40'-0"
9'-4"
14'-0""
18'-8"
28'-0"
11'-6"
15'-4"
23'-0"
1M040 3 5/8"
1M 1-HOUR RATED CONCRETE MASONRY PARTITION
NON-LOAD BEARING
DESIGNATION
NO. FIRE
TEST
(NOTE 8)
"A"
DIM.
1M060 5 5/8"
1M080 7 5/8"
1M120 11 5/8"
STRUCTURE ABOVE
REFER TO TYPICAL HEAD OF PARTITION FIRESTOP DETAIL
CONCRETE UNIT MASONRY (CMU) WITH JOINT
REINFORCEMENT EVERY 2 COURSES
PLAN
BASE
HEAD
TOP OF STRUCTURAL SLAB
"A" OVERALL DIMENSION
BASE JOINT GROUTED SOLID
NOTES:
1) PARTITIONS TO RECEIVE BLOCK FILLER BEFORE PAINTING
WHERE SCHEDULED
2) 1" RADIUS BULLNOSE AT OUTSIDE CORNERS (TYP.)
(NOTE 8)
(NOTE 8)
(NOTE 8)
UL DESIGN NO. U901, U905
8'-6"
"S" MODIFIER
LIMITING HEIGHT (NOTE 1)
5 PSF
REINF.
CMU
(NOTE 9) 2.67"
3.625"
3.625"
EQUIVALENT
THICKNESS
(NOTE 10)
DESIG -
NATION
STC CLASS
(NOTE 2 & 4)
WEIGHT
CLASS
(NOTE 7)
CELL FILL
MATERIAL
(NOTE 3)
S1
S2
S3
LIGHT
LIGHT
LIGHT
HOLLOW
GROUT
SAND
13'-0" (NOTE 9) 3.09"
5.625"
5.625"
S1
S2
S3
LIGHT
LIGHT
LIGHT
HOLLOW
GROUT
SAND
17'-4" (NOTE 9) 4.04"
7.625"
7.625"
S1
S2
S3
LIGHT
LIGHT
LIGHT
HOLLOW
GROUT
SAND
26'-0" (NOTE 9) 5.66"
11.625"
11.625"
S1
S2
S3
LIGHT
LIGHT
LIGHT
HOLLOW
GROUT
SAND
UNGROUTED/PARTIALLY
GROUTED
FULLY GROUTED
10 PSF 15 PSF 5 PSF 10 PSF 15 PSF
9'-0"
12'-0"
18'-0"
10'-0""
15'-0"
13'-4"
20'-0""
26'-8"
40'-0"
9'-4"
14'-0""
18'-8"
28'-0"
11'-6"
15'-4"
23'-0"
AT PARTITIONS WHERE
VERTICAL REINFORCING IS
REQD., PROVIDE REINFORCING
CELL AT EA. SIDE OF C.J.;
REFER TO STRUCTURAL
DRAWINGS FOR REINFORCING
PREMOLDED C.J. FILLER
BOND BREAKER
CMU PARTITION
SEALANT (PROVIDE FIRESTOP
JOINT AT RATED PARTITION
BASIS OF DESIGN
UL NO. U906 (2 HR RATING)
CMU GENERAL NOTES
1. LIMITING HEIGHT PROVIDED IN PARTITION SCHEDULES IS ABBREVIATED AND MAY NOT ADDRESS ALL CONDITIONS OF THE PROJECT. TABLES ARE BASED ON USING TYPE S MORTAR. CONTRACTOR TO VERIFY CODE COMPLIANCE WITH TMS402/602 (2016) OR GOVERNING CODE IF USING OTHER MORTAR TYPE. THE INFORMATION IN THE TABLES IS PROVIDED FOR USE AS A GUIDE AND DOES NOT ALLEVIATE THE CONTRACTOR FROM PROVIDING PARTITION ASSEMBLIES THAT MEET THE DESIGN CRITERIA FOR EACH CONDITION. SEE STRUCTURAL DRAWINGS FOR ALL REINFORCED MASONRY PARTITIONS. COMPLY WITH REQUIREMENTS OF TMS402/602 (2016)
OR APPLICABLE CODES.
2. ALL PARTITIONS SHALL EXTEND TO AND TERMINATE AT THE UNDERSIDE OF STRUCTURE ABOVE UNLESS NOTED OTHERWISE. COORDINATE STRUCTURAL DEFLECTION REQUIREMENTS WITH HEAD OF PARTITION DETAILING TO ACCOMMODATE MOVEMENT. PROVIDE TOP OF PARTITION BRACING AS PER DETAILS ON THIS
SHEET.
3.ALL RATED PARTITIONS SHALL BE PERMANENTLY IDENTIFIED IN CONCEALED SPACES EITHER AS REQUIRED BY CODE OR WITH 2" HIGH LETTERING IN COLOR/VALUE CONTRASTING WITH THE BACKGROUND AND SPACED NO MORE THAN 12 FEET ON CENTER. TEXT SHALL READ AS REQUIRED BY CODE OFFICIAL OR "__ HOUR FIRE AND SMOKE BARRIER - PROTECT ALL OPENINGS." WHERE THESE REQUIREMENTS CONFLICT WITH REQUIREMENTS BY LOCAL AUTHORITY HAVING JURISDICTION THEN REQUIREMENTS BY LOCAL AUTHORITY SHALL GOVERN.
4. WEIGHT CLASSIFICATION DEFINED AS FOLLOWS: LIGHTWEIGHT (LIGHT) - CMU DENSITY LESS THAN 105 LBS/CF, MEDIUM WEIGHT (MED) - CMU DENSITY 105-125 LBS/CF, NORMAL WEIGHT (NORMAL) - CMU DENSITY GREATER
THAN 125 LBS/CF.
5. CONTRACTOR SHALL PROVIDE CERTIFICATION FOR THE FIRE RATING OF THE CMU FROM THE MANUFACTURER BASED ON THE AGGREGATE MATERIAL USED AND EQUIVALENT THICKNESS. FIRE RATING BASED ON IBC 2018, TABLE 721.1 AND THE CALCULATED EQUIVALENT THICKNESS AS FOLLOWS:
CONCRETE MASONRY UNIT (CMU) INTERIOR
PARTITIONS (NON- LOAD BEARING)
AGGREGATE TYPE EQUIVALENT THICKNESS FACE-TO-FACE (INCHES)
4 HOUR 3 HOUR 2 HOUR 1 HOUR
4.7 4.0 3.2 2.1
5.1 4.4 3.6 2.6
5.9 5.0 4.0 2.7
6.2 5.3 4.2 2.8
EXPANDED SLAG OR PUMICECONCRETE
MASONRY
UNITS EXPANDED CLAY, SHALE OR SLATE
LIMESTONE, CINDERS OR AIR-
COOLED SLAG
CALCEROUS OR SILICEOUS GRAVEL
6. CONCRETE MASONRY DESIGN AND CONSTRUCTION SHALL CONFORM TO THE FOLLOWNG:
A. TMS 402, BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES
B. TMS 602, SPECIFICATION FOR MASONRY STRUCTURES
7. REINFORCED ALL CMU PARTITIONS WITH #4 @ 48" VERTICAL, LAP BARS 24".
8. PROVIDE MIN. 1 #5 VERTICAL, GROUTED FULL HEIGHT IN THE FIRST CELL AT EACH SIDE OF OPENINGS, AT WALL
ENDS, AT EACH SIDE OF CONTROL JOINTS AND AT CORNERS.
9. SPACE MASONRY CONTROL JOINTS AT THE LESSER OF: LENGTH TO HEIGHT RATIO = 1.5 OR 25'-0".
CMU MASONRY CONTROL JOINT PLACEMENT DIAGRAM
STRUCTURE ABOVE
FINISHED CEILING
MASONRY CONTROL JOINT. REFERENCE CONTROL JOINT DETAIL FOR
ADDITIONAL INFORMATION
FLOOR SLAB
SCHEDULED PARTITION BASE
REFERENCE CMU GENERAL NOTE 9 FOR
ADDITIONAL GUIDELINES REGARDING
THE PLACEMENT OF CMU CONTROL
JOINTS
STEEL FLOOR DECK
W/ CONCRETE FILL
MINERAL WOOL BLANKET
INSULATION FILL
FIRESTOP SEALANT
5"x3"x12 GA. MIN. GALV. STL.
ANGLES - 12" LONG STAGGERED
24" O.C. ON OPP. SIDES OF
PARTITION
RATED CONCRETE MASONRY
NON-LOAD BEARING PARTITION
8" WIDE 10 GA. STL.
WELD PLATE AT 48" O.C.
(INSTALL ANGLES AFTER
FIRESTOP SEALANT
OBSTRUCTION PREVENTING
ACCESS TO ONE SIDE OF PARTITION
2"
BASIS OF DESIGN:
U.L. NO. HW - D - 0286 MIN 8" NOMINAL CMU PARTITION
FILL TOP CELLS OF CMU WITH
MORTAR FOR THIS RATING
191 Peachtree Street NE Suite 2400
Atlanta, GA 30303-1770
(404) 237-2000 coopercarry.com
Principal-in-Charge
Project Manager
Project Architect
Staff Architect
Project No.
Date
Drawing No.
A
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
B C
D E
F G
H J
K L
M N
P
A B
C D
E F
G H
J K
L M
N P
© 2026 COOPER CARRY
ISSUED FOR CONSTRUCTION
GA DEPT OF EDUCATION DATA
FACILITY CODE: 628-1605-1320.01
FTE FOR THIS SITE: 2100
INSTRUCTIONAL UNITS: 108 (96 EXISTING,
22 NEW)
A u to d e s k D o c s /2
W o o d s to c k H
S
C T
A E l a b s /W
O O
D S
T O
C K
H S
C
T A
E L
A B
S V
.r v t
/1
/2
:0
:0
P
M
A9.00
04/02/2026
20260084Designer
Approver
Checker
Author
INTERIOR PARTITIONS
WOODSTOCK HS CTAE RMA
2010 TOWNE LAKE HILLS S. DR.
WOODSTOCK, GA 30189
CHEROKEE COUNTY SCHOOL SYSTEM
P R
O
JE
C T
N U
M B
E R
: 2
P
R O
JE
C
T N
A M
E : W
O O
D S
TO
C
K H
S C
TA
E
R M
A S
H E
E T
N U
M B
E R
: A 9.
IN
TE
R
IO
R P
A R
TI
TI
O N
S
SCALE: 1 1/2" = 1'-0"A9.00
5 CONTROL JOINT DETAIL - 1 & 2 HR
SCALE: 1 1/2" = 1'-0"A9.00
4 CONTROL JOINT DETAIL - NON RATED
SCALE: 1 1/2" = 1'-0"A9.00
7 HORIZONTAL MEMBRANE - 1 & 2 HR
SCALE: 1 1/2" = 1'-0"A9.00
1 WALL PRIORITY LEGEND
SCALE: 1 1/2" = 1'-0"A9.00
TYPICAL DETAILS - INTERSECTIONS OF RATED
WALLS
SCALE: 1 1/2" = 1'-0"A9.00
3 TYPICAL DOOR LOCATION
SCALE: 1 1/2" = 1'-0"A9.00
6 FIRE/SMOKE WALL AT EXTERIOR WALL
SCALE: 3" = 1'-0"A9.00
10 CMU CONTROL JOINT DETAIL
SCALE: 3" = 1'-0"A9.00
CMU HEAD WALL DETAIL AT DECK B - I SIDE -
2HR
ISSUANCES
H 2"
2" W 2"
4" H
2" W 2"
DOOR FRAME TYPES
SINGLE DOOR FRAME
HOLLOW METAL,
SINGLE DOOR FRAME
HOLLOW METAL, WITH 4" HEAD
DOUBLE DOOR FRAME
HOLLOW METAL
2" H
2" W 2"
DOUBLE DOOR FRAME
HOLLOW METAL, WITH 4" HEAD
2" W 2"
4" H
NOTE: COORDINATE FRAME SIZES WITH SCHEDULED DOOR PANEL SIZES
EQ EQ EQ EQ
W
SF01
SF SINGLE FLUSH
DOOR TYPES
H
W
SN01
SN NARROW LITE
H
1'
0" 2'
6"
8" 8"
CONCRETE MASONRY UNIT
PARTITION
SEALANT, TYP
4"
HOLLOW METAL FRAME -
REFER TO DOOR SCHEDULE
DOOR - REFER TO
DOOR SCHEDULE
PARTITION THICKNESS
COORDINATE WITH
1/2" 1/2"
CONCRETE
MASONRY UNIT
PARTITION
SEALANT, TYP
HOLLOW METAL FRAME -
REFER TO DOOR SCHEDULE
SPOT GROUT AT JAMB
ANCHORS
DOOR - REFER TO DOOR
SCHEDULE
P A
R
TI
TI
O
N T
H
IC
K N
E S
S
C O
O R
D
IN
A
TE
W
IT
H
2"
1/ 2"
1/ 2"
191 Peachtree Street NE Suite 2400
Atlanta, GA 30303-1770
(404) 237-2000 coopercarry.com
Principal-in-Charge
Project Manager
Project Architect
Staff Architect
Project No.
Date
Drawing No.
A
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
B C
D E
F G
H J
K L
M N
P
A B
C D
E F
G H
J K
L M
N P
© 2026 COOPER CARRY
ISSUED FOR CONSTRUCTION
GA DEPT OF EDUCATION DATA
FACILITY CODE: 628-1605-1320.01
FTE FOR THIS SITE: 2100
INSTRUCTIONAL UNITS: 108 (96 EXISTING,
22 NEW)
A u to d e s k D o c s /2
W o o d s to c k H
S
C T
A E l a b s /W
O O
D S
T O
C K
H S
C
T A
E L
A B
S V
.r v t
/1
/2
:0
:2
P
M
A9.10
04/02/2026
20260084SOPHIA TARKHAN
BRIAN MITCHELL
CLAIRE COUVILLON
DOOR SCHEDULE AND TYPES
WOODSTOCK HS CTAE RMA
2010 TOWNE LAKE HILLS S. DR.
WOODSTOCK, GA 30189
CHEROKEE COUNTY SCHOOL SYSTEM
P R
O
JE
C T
N U
M B
E R
: 2
P
R O
JE
C
T N
A M
E : W
O O
D S
TO
C
K H
S C
TA
E
R M
A S
H E
E T
N U
M B
E R
: A 9.
D O
O R
S C
H E
D U
LE
A
N D
T Y
P E
S
DOOR SCHEDULE
NO. ROOM NAME
DOOR FRAME
DS DOOR
TYPE
FRAME
DS FRAME
TPYE FIRE RATING COMMENTSWIDTH HEIGHT THICKNESS MATERIAL
HARDWARE
SET HEAD JAMB MATERIAL
703 INFORMATION TECHNOLGY
LAB (CYBERSECURITY)
3' - 0" 7' - 0" 0' - 1 3/4" ETR ETR ETR ETR EXISTING DOOR AND FRAME TO REMAIN
703.1 STOR. 3' - 0" 7' - 0" 0' - 1 3/4" ETR ETR ETR ETR EXISTING DOOR AND FRAME TO REMAIN
703.2 OFFICE 3' - 0" 7' - 0" 0' - 1 3/4" ETR ETR ETR ETR EXISTING DOOR AND FRAME TO REMAIN
703.3 ELEC. 3' - 0" 7' - 0" 0' - 1 3/4" WD 1/A9.10 SF 2.A9.10 HM 02
703.4 IDF 3' - 0" 7' - 0" 0' - 1 3/4" WD 1/A9.10 SF 2.A9.10 HM 02
703.5 INFORMATION TECHNOLGY
LAB (CYBERSECURITY)
3' - 0" 7' - 0" 0' - 1 3/4" ETR ETR ETR ETR EXISTING DOOR AND FRAME TO REMAIN
703.6 FLIGHT OPERATIONS LAB 3' - 0" 7' - 0" 0' - 1 3/4" ETR ETR ETR EXISTING DOOR AND FRAME TO REMAIN
705.1 FLIGHT OPERATIONS LAB 3' - 0" 7' - 0" 0' - 1 3/4" ETR ETR ETR ETR…