Attachment_A_-_Drawings.pdf
PDF 9 MB Posted
- Attached to
- Dehumidification Upgrades at NCTC Federal contract opportunity
- Solicitation number
- 140F0918B0002
About this file
Attachment A - Drawings
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140F0918B0002_Amd_0003.pdf | ||
| Attachment_K_-__Q&A_Set_2.pdf | ||
| Sol_140F0918B0002_Amd_0002.pdf | ||
| Attachment_J_-_140F0918B0002_Q&A_Set_1.pdf | ||
| Attachment_I_-_Site_Visit_Agenda.pdf | ||
| Sol_140F0918B0002_Amd_0001.pdf | ||
| Attachment_H_-_Site_Visit_Attendance_Sheet.pdf | ||
| Attachment_E_-_SF-25A_Payment_Bond.pdf | ||
| Attachment_B_-_Specifications.pdf | ||
| Sol_140F0918B0002.pdf | ||
| Attachment_F_-_DI-137_-_DOI_Release_of_Claims.pdf | ||
| Attachment_D_-_SF25_Performance_Bond.pdf | ||
| Attachment_G_-_Important_Notice_to_Bidders.pdf | ||
| Attachment_C_-_Wage_Determination.pdf |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D
C
SHEET NO.
G-001-H1
M-001-H1
M-002-H1
M-101-H1
M-401-H1
M-501-H1
B M-601-H1
M-901-H1
E-001-H1
E-101-H1
E-601-H1
A
2 3 4
SHEET INDEX
SHEET NAME
GENERAL
COVER SHEET & SHEET INDEX
MECHANICAL
MECHANICAL ABBREVIATIONS AND GENERAL NOTES
MECHANICAL LEGENDS
MECHANICAL GROUND FLOOR PLAN
MECHANICAL ENLARGED PLANS
MECHANICAL DETAILS
MECHANICAL SCHEDULES
MECHANICAL PHOTOS
ELECTRICAL
ELECTRICAL ABBREVIATIONS AND GENERAL NOTES
ELECTRICAL GROUND FLOOR PLAN
ELECTRICAL SCHEDULES
NATIONAL CONSERVATION TRAINING CENTER
SHEPHERDSTOWN, WEST VIRGINIA
AUGUST 17, 2017
ic t
KnDwl�dge R�$tJutt�s snd r N.hnt:Jlogir;,�
I
PROJECT SITE
Aed
Lot Wes!
Pond
Offi"e:es
Fa/Jeri
Aida leO'fJOld LMge
3500 Parkway Lane, Suite 500 Norcross, GA 30092 Phone (678) 336-7740 Fax(678)336-7744
JOB NO. 1170656
Yellovv
Lot
1wi, Cr!'n!ral PJarr,r aclleJ Carson lodge
100% DESIGN SUBMISSION
LU
w
CD
w z
U) w
U.S.
l"lSII & WILDLll•'E
St:,;KVlCt:
d z d z z 0 t;
<( d u 0:
zI- ::J z w 0 0 ---' (/) ' (.) ' ii: ' w s: LU □
;: <( D
CD (/) I-
□ w 0 " ---' (.) ;: 0.
CD
N 0 u..i .
:E w ---'" ;: I= <( t; u_
CD
:E "'0 z "' 1-Z s: o-:::, ---' <I) □ <I) a. <(
0.
0.
w z
0.
w w
:ii z
--I W(.)
!::! 0:
<I)<(
SHEET
IDENTIFICATION
G-001-H1
GENERAL MECHANICAL NOTES
1. INSTALLATION OF HVAC WORK SHALL BE COORDINATED
WITH OTHER TRADES BEFORE ANY INSTALLATION IS
MADE. EQUIPMENT, PIPING OR DUCTWORK INTERFERING
WITH OTHER TRADES SHALL BE RELOCATED AS
REQUIRED AT NO ADDITIONAL COST.
2. COORDINATE MECHANICAL AND ELECTRICAL SUCH THAT
MECHANICAL PIPING, DUCTWORK AND EQUIPMENT IS NOT
LOCATED OVER OR ABOVE ANY ELECTRICAL,
COMMUNICATIONS, OR DATA EQUIPMENT.
3. AT START OF CONSTRUCTION, PREPARE TYPED LISTS OF
EQUIPMENT BEING SUPPLIED REQUIRING ELECTRICAL WORK,
AND SEND LISTS TO THE ELECTRICAL CONTRACTOR FOR
REVIEW AND COORDINATION.
4. WRITTEN DIMENSIONS ON DRAWINGS SHALL HAVE
PRECEDENCE OVER SCALED DIMENSIONS.
5. EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH
MANUFACTURER'S APPROVED PUBLISHED LITERATURE.
6. INSTALLATION OF EQUIPMENT SHALL PERMIT ACCESSIBILITY
FOR SERVICE AND/OR REPLACEMENT.
7. CEILING-MOUNTED EQUIPMENT SHALL BE INSTALLED IN SUCH
A MANNER THAT LIGHTS, PIPING, DUCTWORK, ETC., DO NOT
BLOCK ACCESS TO EQUIPMENT AND RELATED ACCESSORIES.
8. COORDINATE ALL WALL, FLOOR AND ROOF PENETRATIONS
WITH THE CONSTRUCTION PROFESSIONAL.
9. CAULK WITH SILICONE ALL GAPS BETWEEN WALL, CEILING
AND FLOOR OPENINGS AND HVAC EQUIPMENT PENETRATIONS.
PATCH LARGE GAPS BEFORE CAULKING IS APPLIED.
10. SUPPLEMENTAL STEEL MEMBERS REQUIRED TO SUPPORT
HVAC EQUIPMENT FROM MAIN STRUCTURE SHALL BE
PROVIDED.
11. DUCTWORK AIR DISTRIBUTION SYSTEMS SHALL BE INSTALLED
IN ACCORDANCE WITH SMACNA STANDARDS AND THE
PRESSURE CLASSIFICATION OF EACH INDIVIDUAL DUCTWORK
SYSTEM, NOT LESS THAN 2 IN.W.G., SEAL CLASS A (LEAKAGE
CLASS 6, OR 4% OF THE TOTAL AIR FLOW THROUGH THE
DUCT). DUCT SIZES SHOWN ON DRAWINGS ARE INSIDE CLEAR
DIMENSIONS.
12. VOLUME DAMPERS SHALL BE PROVIDED AT EACH NEW MAIN
BRANCH TAKE-OFF AND IN SUCH OTHER LOCATIONS WHERE
REQUIRED TO PROPERLY BALANCE THE SYSTEM.
13. INSTRUMENT TEST HOLES SHALL BE PROVIDED IN AIR
DISTRIBUTION SYSTEMS WHEREVER VOLUME DAMPERS ARE
SHOWN.
14. SQUARE ELBOWS SHALL ONLY BE USED WHERE SPACE
LIMITATIONS PREVENT USE OF 1.5 RADIUS ELBOW AND ONLY
UPON APPROVAL OF DESIGN PROFESSIONAL. PROVIDE TURNING
VANES IN ALL 45° AND 90° SQUARE ELBOWS. TURNING VANES
SHALL BE SINGLE THICKNESS TYPE WITHOUT RAILING EDGE. IF
TURNING VANES LONGER THAN 36 INCHES ARE REQUIRED, THEY
SHALL BE DOUBLE THICKNESS TYPE FOR STRENGTH.
15. PROVIDE SHEETMETAL TRANSITIONS AT AIR HANDLING UNITS, HEAT
PUMP UNITS, FANS, AND OTHER SIMILAR HVAC EQUIPMENT.
FLEXIBLE DUCT CONNECTORS OR SOUND ATTENUATION
DEVICES SHALL BE USED ON CONNECTION TO AIR HANDLING
EQUIPMENT TO REDUCE NOISE TRANSFER INTO OCCUPIED
SPACES.
16.
BLANK OFF INACTIVE PORTIONS OF LOUVERS UTILIZED
FOR INTAKE OR DISCHARGE FOR HVAC EQUIPMENT. ENTIRE
LOUVERS NOT UTILIZED SHALL BE BLANKED OFF BY THE
LOUVER MANUFACTURER. REFER TO ARCHITECTURAL
DRAWINGS FOR LOUVER LOCATIONS AND HVAC DRAWINGS
FOR HVAC EQUIPMENT CONNECTIONS.
17. EXACT LOCATIONS OF THERMOSTATS, CO2 SENSORS, AND
EMCS SENSORS SHALL BE COORDINATED WITH FINAL
LOCATIONS OF WALL-MOUNTED ARCHITECTURAL AND
ELECTRICAL EQUIPMENT. MOUNT THERMOSTATS AND HUMIDISTAT
SENSORS MINIMUM 48" AFF.
18. SUPPLY AND OUTDOOR AIR DUCTWORK SHALL
BE INSULATED TO MEET OR EXCEED ASHRAE 90.1-2010.
INTERIOR SUPPLY, RETURN, AND OUTDOOR AIR DUCTWORK
SHALL BE INSULATED FOR A MINIMUM VALUE OF R-6.
19.
COORDINATE CONDENSATE DRAIN PIPING WITH EXISTING
CONDITIONS. PROVIDE CONDENSATE PUMPS
AS REQUIRED WHERE SUFFICIENT SLOPE IS NOT
AVAILABLE FOR STANDARD GRAVITY DRAIN, WITH
OVERRIDE SWITCH TO POWER DOWN THE ASSOCIATED AIR
HANDLING EQUIPMENT IN CASE OF CONDENSATE PUMP
FAILURE. CONDENSATE DRAIN PIPING SHALL BE SLOPED
FOR GRAVITY AT A MINIMUM OF 2% SLOPE.
20. PROVIDE SUPPORTS FOR PIPING AND DUCTWORK IN
ACCORDANCE WITH SPECIFICATIONS. STRAP SUPPORTS
INSTALLED IN DIRECT CONTACT WITH PIPING OR DUCTWORK
SHALL HAVE INSULATION APPLIED AROUND STRAP FOR
CONTINUOUS INSULATION VALUE FOR THE PIPE OR DUCT.
FOR SUPPORT OF PRE-INSULATED PIPING OR DUCTWORK, USE
HIGH-DENSITY INSULATION ON BOTTOM OF PIPE OR DUCT TO
PREVENT CRUSHING OR PROVIDE SADDLES OR SHIELDS TO
PREVENT CRUSHING OF INSULATION. ADHERE THE SADDLE
TO THE INSULATION POSITION SUPPORT LOCATED IN
CENTER OF THE SADDLE WHILE SYSTEM IS AT NOMINAL
OPERATING TEMPERATURE. PIPE HANGERS AND SUPPORTS
SHALL BE IN ACCORDANCE WITH MSS SP-58.
GENERAL MECH. ABBREVIATIONS
@ AT
& AND
AFF ABOVE FINISHED FLOOR
A/C ABOVE CEILING
AD AUTOMATIC DAMPER
ADJ. ADJUSTABLE
AFMS AIRFLOW MEASURING STATION
AHU AIR HANDLING UNIT
ARCH ARCHITECTURAL OR ARCHITECT
AS AIR SEPARATOR
ASHRAE AMERICAN SOCIETY OF HEATING, REFRIGERATING
AND AIR CONDITIONING ENGINEERS
AUX. AUXILIARY
B BOILER
BD BACKDRAFT DAMPER
BLDG BUILDING
BFF, BFS BELOW FINISHED FLOOR, BELOW FINISHED SLAB
BTU, BTUh BRITISH THERMAL UNITS, BTUs PER HOUR
CAV CONSTANT AIR VOLUME
CCC CLOSED CIRCUIT COOLER
CD CONDENSATE DRAIN LINE
CFM CUBIC FEET PER MINUTE
CMU CONCRETE MASONRY UNIT
CO CLEANOUT
CO2 CARBON DIOXIDE
CONC CONCRETE
CONN. CONNECT, CONNECTING, CONNECTION
CONT. CONTINUED
COP COEFFICIENT OF PERFORMANCE
COR CONTRACTING OFFICER'S (OWNER'S)
REPRESENTATIVE
CU CONDENSING UNIT
CWR CONDENSER WATER RETURN
CWS CONDENSER WATER SUPPLY
D DEPTH
DB, Tdb DRY BULB (TEMPERATURE)
DbA DECIBELS
DDC DIRECT DIGITAL CONTROLS
DIA DIAMETER
DN DOWN
DP DEEP
dP, PD DELTA PRESSURE, PRESSURE DROP
DWG DRAWING
DX DIRECT EXPANSION
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
EER ENERGY EFFICIENCY RATIO
EF EXHAUST FAN
EFF EFFICIENCY
ELEC ELECTRICAL
EMCS ENERGY MONITORING AND CONTROL SYSTEM
ERU ENERGY RECOVERY UNIT
ET EXPANSION TANK
ESP EXTERNAL STATIC PRESSURE
EWT ENTERING WATER TEMPERATURE
EXT EXTERIOR
EXH EXHAUST
EXIST. EXISTING
DEG. F (°F) DEGREES FAHRENHEIT
FD FIRE DAMPER, FLOOR DRAIN
FFE FINISHED FLOOR ELEVATION
FLA FULL LOAD AMPS
FOB, FOT FLAT ON BOTTOM, FLAT ON TOP
FSD FIRE SMOKE DAMPER
FT FOOT OR FEET
FT. WG FEET WATER GAUGE
HP HEAT PUMP, HORSEPOWER
HR HOUR
HTG HEATING
HTR HEATER
HVAC HEATING, VENTILATING AND AIR
CONDITIONING
HZ
HERTZ
IN INCHE(S)
IN WC INCHES WATER COLUMN
IN WG INCHES WATER GAUGE
KW KILOWATTS
L LENGTH
LAT LEAVING AIR TEMPERATURE
LBS POUNDS
LBF/IN2 POUND FORCE PER SQUARE INCH
LWT LEAVING WATER TEMPERATURE
MAX MAXIMUM
MBH 1,000 x BTUs
MCA MINIMUM CIRCUIT AMPACITY
MD MOTORIZED DAMPER
MERV MINIMUM EFFICIENCY REPORTING VALUE
MECH MECHANICAL
MFR, MFG MANUFACTURER, MANUFACTURING
MIN MINIMUM
MOCP MAXIMUM OVER CURRENT PROTECTION
MTD MOUNTED
MUW MAKE UP WATER (DOMESTIC)
NO. NUMBER
NTS NOT TO SCALE
OA OUTSIDE AIR
OD OUTSIDE DIAMETER
GENERAL MECH. ABBREVIATIONS (CONT.)
PD PRESSURE DROP
PH PHASE
PPM PARTS PER MILLION
PRV PRESSURE RELIEF VALVE
QTY QUANTITY
RA RETURN AIR
RG RETURN GRILLE
RH RELATIVE HUMIDITY
RL REFRIGERANT LIQUID
RM ROOM
RPM REVOLUTIONS PER MINUTE,
ROTATIONS PER MINUTE
RS REFRIGERANT SUCTION
SA SUPPLY AIR
SD SMOKE DAMPER, SMOKE DETECTOR
SEER SEASONAL ENERGY EFFICIENCY RATIO
SF SUPPLY FAN
SMACNA SHEET METAL AND AIR CONDITIONING
CONTRACTORS' NATIONAL ASSOCIATION
SP STATIC PRESSURE
SS, SST STAINLESS STEEL
T'STAT THERMOSTAT
TEMP TEMPERATURE
THR TOTAL HEAT REJECTION
TYP TYPICAL
UH UNIT HEATER
V VOLTAGE
VAV VARIABLE AIR VOLUME
VD VOLUME DAMPER
VFD VARIABLE FREQUENCY DRIVE
VSD VARIABLE SPEED DRIVE
W WATT
W/ WITH
W/O WITHOUT
WB, Twb WET BULB (TEMPERATURE)
WD WIDE, WIDTH
WG WATER GAUGE
WWSP WATER WATER HEAT PUMP
MVD MANUAL VOLUME DAMPER
TG TRANSFER GRILLE
THA TOTAL HEAT ABSORPTION
HD HEAD
C CHILLER
PCF POUNDS PER CUBIC FOOT
MAU MAKEUP AIR UNIT
DCW DOMESTIC COLD WATER
FDB DEGREES FAHRENHEIT DRY BULB
FWB DEGREES FAHRENHEIT WET BULB
SB SECURITY BARS
E.W.T.& B. EACH WAY TOP & BOTTOM
Cv VALVE FLOW COEFFICIENT
CHWS CHILLED WATER SUPPLY
CHWR CHILLED WATER RETURN
FTR FINNED TUBE RADIATOR
GA GAUGE
GEV GRAVITY EXHAUST VENTILATOR
GPM GALLONS PER MINUTE
GIV GRAVITY INTAKE VENTILATOR
GTS GEOTHERMAL SUPPLY
GTR GEOTHERMAL RETURN
H HEIGHT
HWR HOT WATER RETURN
HWS HOT WATER SUPPLY
IDU INDOOR UNIT
GWB GYPSUM WALLBOARD
WPD WATER PRESSURE DROP
WSA WIRE SIZE AMPS
NEMA NATIONAL ELECTRICAL MANUFACTURER'S
ASSOCIATION
OPD OVERCURRENT PROTECTION DEVICE
P PUMP
PSI, PSIG POUNDS PER SQUARE INCH, PSI GAUGE
UL UNDERWRITERS LABORATORIES
21. ALL DIFFERENTIAL PRESSURE SENSOR LOCATIONS TO HAVE
PORTS FOR TEST AND BALANCE VERIFICATION.
22. EXISTING UTILITIES MAY NEED TO BE SHIFTED TO ACCOMMODATE NEW
WORK. IT IS THE CONTRACTOR'S RESPONSIBILITY TO MOVE ANY
UTILITY, DUCT, PIPING, OR FIXTURES NEEDED TO INSTALL NEW WORK.
SEE PHOTOS ON M-901 SHEET FOR EXISTING CONDITIONS.
23. NCTC CAMPUS ONLY USES JOHNSON CONTROLS. LOCAL CONTACT IS
BRIAN BONNEY (OFFICE: 410-527-2746 AND EMAIL
BRIAN.D.BONNEY@JCI.COM)
1 2 3 4 5
A
B
C
D
D W
N
B
Y
C K
D
B
Y
S U
B M
I T
T E
D
B
Y
D A
T E
SHEET
IDENTIFICATION
D E
S I G
N E
D
B
Y
F I L
E
N
A M
E
P a r k w a y
L a n e
S u i t e
N o r c r o s s
G
A
P h o n e
F a x
P L
O T
A T
E
S I Z
E
A R
C H
S O
L I C
I T
A T
I O
N
N
O
C O
N T
R A
N
F I L
E
N
O
A P
P R
D
A T
E D
E S
C R
I P
T I O
N M
A R
K
U S
F
I S
H
A
W
I L
D L
I F
E
N C
M
P U
S
D
I S
T R
I C
T
S H
E P
H E
R D
S T
O W
N
W
V
D E
H U
M I D
I F
I C
A T
I O
N
S
Y S
T E
M
F
O R
L O
D G
E
A
L D
O
L
E O
P O
L
S H
E P
H E
R D
S T
O W
N
W
E S
T
V
I R
G I N
I A
J O
B
N
O
100% DESIGN SUBMISSION
D W
E
D W
E M
I Z
E S
A
G E
N E
R A
L
N
O T
E
D
A B
B R
E V
I A
T I O
N
M-001-H1
AIR DISTRIBUTION DEVICE TAGS
DIFFUSER TYPE
A
AIRFLOW
DIFFUSER TYPE
A
24x24 FACE SIZE
SUPPLY/RETURN/EXHAUST TAGS
TRANSFER GRILLE TAGS
M501
PLAN NORTH
DRAWING/DETAIL REFERENCE KEY
REFER TO
DETAIL NUMBER
SHEET NUMBER OF DETAIL
RE:2/M501
NORTH ARROW
A
J
SD
SP
F
T
TH
A
C
DUCT SMOKE DETECTOR
CARBON DIOXIDE SENSOR
DRAWING NOTE REFERENCE
OVAL OR FLAT OVAL
CONTROL WIRING
STATIC PRESSURE SENSOR
ROUND
THERMOSTAT
FIRESTAT
TEMPERATURE SENSOR
HUMIDITY SENSOR
MISCELLANEOUS LEGEND
H
T
120 VOLT STAND BY POWER JUNCTION
BOX PROVIDED BY THE ELECTRICAL
CONTRACTOR JUNCTION BOX IS
DEDICATED FOR USE BY THE CONTROLS
CONTRACTOR.
VARIABLE FREQUENCY DRIVEVFD
THERMOSTAT/HUMIDISTAT
PIPING LEGEND
EXPANSION JOINT
FLEXIBLE CONNECTION
CLEANOUT
WATER METER
FLOOR CLEANOUT
THERMOMETER
PRESSURE REDUCING VALVE
MANUAL AIR VENT
WITH BALL VALVE
PRESSURE/TEMPERATURE TAP
PRESSURE SWITCH
PLUG VALVE
FLOW SWITCH
T&P RELIEF VALVE
AUTOMATIC AIR VENT
PRESSURE GAUGE WITH GAUGE COCK
PS
FS
BUTTERFLY VALVE
STRAINER WITH BLOWDOWN VALVE,
FLOW MEASURING/BALANCING/
SHUT-OFF VALVE
GATE VALVE
CHECK VALVE
BALL VALVE
CAP AND CHAIN
3-WAY CONTROL VALVE
2-WAY CONTROL VALVE
CWR
CONDENSER WATER RETURN
CONCENTRIC REDUCER
DIRECTION OF FLOW
DIRECTION OF SLOPE DOWN
ECCENTRIC REDUCER
PIPE FLANGE
PIPE CAP
PIPE GUIDE
PIPE ANCHOR
X
UNION
TEE OUTLET UP
CONDENSATE DRAIN
BRANCH BOTTOM CONNECTION
PUMPED CONDENSATE
BRANCH TOP CONNECTION
ELBOW UP
ELBOW DOWN
RISE OR DROP
TEE OUTLET DOWN
PC
CD
REFRIGERANT SUCTION
RS
CWS
CONDENSER WATER SUPPLY
HWS
HEATING WATER SUPPLY
HWR
HOT WATER RETURN
M
SUPPLY OR OUTSIDE AIR DUCT UP
AD
FD(3) - FIRE DAMPER, 3 HOUR RATING
FD - FIRE DAMPER, 1 HOUR RATING
FIRE DAMPER TYPE:
H
UP
DN
DUCT MOUNTED HUMIDIFIER
RISE IN DUCT
DROP IN DUCT
RETURN OR EXHAUST AIR DUCT DOWN
RETURN OR EXHAUST AIR DUCT UP
SUPPLY OR OUTSIDE AIR DUCT DOWN
30x14
SQUARE TO ROUND DUCT BRANCH TAKE-OFF
FLARED SPIN-IN WITH DAMPER AND
FLEX DUCT (DIFFUSER CONNECTION)
ROUND DUCT BRANCH TAKE-OFF FROM
RECTANGULAR MAIN WITH CONICAL TAP
FLEXIBLE DUCT CONNECTION
WITH 45 DEGREE BRANCH INLET
FLOW ARROW
DUCT SIZE TRANSITION
RECTANGULAR DUCT BRANCH TAKE-OFF
WITH 45 DEGREE BRANCH INLET
DASHED LINES INDICATE 2" ACOUSTICAL LINER
90 DEGREE DUCT ELBOW WITH TURNING VANES
FLEXIBLE DUCT
24"
DUCTWORK LEGEND
RETURN AIR DEVICE
ROUND DUCT. DIAMETER INDICATED IN INCHES.
IN-LINE 90 DEGREE RISE/DROP IN
SUPPLY DUCT (RIGHT SIDE IS HIGHER)
IN-LINE 90 DEGREE RISE/DROP IN
RETURN DUCT (RIGHT SIDE IS HIGHER)
FD
SD
AD - AUTOMATIC DAMPER
DAMPER TYPE:
MD - MOTORIZED DAMPER
VD
SMOKE DAMPER
VOLUME/BALANCING DAMPER
(LABEL MAY BE OMITTED)
BD
BACKDRAFT DAMPER
(COUNTER-BALANCED UNLESS
OTHERWISE NOTED)
RADIUS DUCT ELBOW - ROUND OR
RECTANGULAR (MIN. 1.5 RADIUS UNLESS
OTHERWISE NOTED)
RECTANGULAR DUCT, SIZE INDICATED IN
INCHES, FIRST NUMBER IS SIDE SHOWN
SUPPLY AIR DIFFUSER -
FLOW ARROWS INDICATE AIR
PATTERN.
NO FLOW ARROWS SHOWN INDICATES
4-WAY PATTERN.
FSD
COMBINATION
FIRE/SMOKE DAMPER
EXHAUST AIR DEVICE
M
VFD
M
T
DP
FS
RH
SD
CT
M
FS
C
PS
SP
CONTROLS LEGEND
FAN
PUMP
ENERGY WHEEL
COIL - COOLING
MOTORIZED DAMPER
FILTERS
MOTORIZED 2-WAY CONTROL VALVE
VARIABLE FREQUENCY DRIVE
MOTOR
CURRENT TRANSDUCER
TEMPERATURE SENSOR
HUMIDITY SENSOR
CARBON DIOXIDE SENSOR
DIFFERENTIAL PRESSURE SENSOR
FLOW SENSOR/ STATION
PRESSURE SWITCH
STATIC PRESSURE SENSOR
DUCT SMOKE DETECTOR
FREEZESTAT
TEMPERATURE SENSOR - PIPE
SIGNAL TO DDC SYSTEM
SIGNAL FROM DDC SYSTEM
DDC
DDC
COIL - HEATING
39.40 N
LONGITUDE:
ELEVATION:
LATITUDE:
SUMMER DESIGN WET BULB (1%):
SUMMER DESIGN DRY BULB (1%):
WINTER DESIGN DRY BULB (99%):
STANDARD DESIGN CONDITIONS:
15.8°F
75.4°F
90.4°F
77.98 W
535 FT.
HVAC DESIGN CRITERIA
LOCATION: EASTERN WV REGNL SHE, WV,
USA (WMO#724177)
*STANDARD & CRITICAL DESIGN CONDITIONS FROM ASHRAE
MEAN COINCIDENT DRY BULB (1%):
HUMIDITY RATIO (1%):
DEHUMIDIFICATION DESIGN CONDITIONS:
122.5
80.0°F
DEWPOINT (99%): 72.4°F
CONNECT TO EXISTING
FLOOR DRAIN
1 2 3 4 5
A
B
C
D
D W
N
B
Y
C K
D
B
Y
S U
B M
I T
T E
D
B
Y
D A
T E
SHEET
IDENTIFICATION
D E
S I G
N E
D
B
Y
F I L
E
N
A M
E
P a r k w a y
L a n e
S u i t e
N o r c r o s s
G
A
P h o n e
F a x
P L
T
E
S I Z
E
A R
O
L I C
I T
A T
I O
N
N
O
C O
N T
R A
F I L
E
N
O
A P
P R
D
A T
E D
E S
C R
I P
T I O
N M
A R
K
U S
F
I S
H
A
L
D L
I F
E
N C
M
P U
S
D
I S
T R
I C
T
S H
E P
H E
R D
S T
O W
N
W
V
D E
H U
M I D
I F
I C
A T
I O
N
S
Y S
T E
M
F
O R
L O
D G
E
A
L D
O
L
E O
P O
S H
E P
H E
R D
S T
O W
N
W
E S
T
V
I R
G I N
I A
J O
B
N
O
100% DESIGN SUBMISSION
D W
E
D W
E M
I Z
E S
A
M E
C H
A N
I C
A L
L E
G E
N D
M-002-H1
M
G20H
MECHANICAL
ROOM
SMALL
G02H
MECHANICAL
ROOM
LARGE
G21H
GENERAL
STORAGE
H1-R-1
1 2 3 4 5
A
B
C
D
D W
N
B
Y
C K
D
B
Y
S U
B M
I T
T E
D
B
Y
D A
T E
SHEET
IDENTIFICATION
D E
S I G
N E
D
B
Y
F I L
E
N
A M
E
P a r k w a y
L a n e
S u i t e
N o r c r o s s
G
A
P h o n e
F a x
P L
T
E
S I Z
E
A R
O
L I C
I T
A T
I O
N
N
O
C O
N T
R A
F I L
E
N
O
A P
P R
D
A T
E D
E S
C R
I P
T I O
N M
A R
K
U S
F
I S
H
A
L
D L
I F
E
N C
M
P U
S
D
I S
T R
I C
T
S H
E P
H E
R D
S T
O W
N
W
V
D E
H U
M I D
I F
I C
A T
I O
N
S
Y S
T E
M
F
O R
L O
D G
E
A
L D
O
L
E O
P O
S H
E P
H E
R D
S T
O W
N
W
E S
T
V
I R
G I N
I A
J O
B
N
O
100% DESIGN SUBMISSION
D W
E
D W
E M
I Z
E S
A
SCALE: 1/8" = 1'-0"
8 0 8 16
SCALE: 1/8" = 1'-0"
H1 (ALDO LEOPOLD) - GROUND FLOOR
GENERAL NOTES:
1. DRAWINGS ARE BASED OFF OF AS-BUILT DRAWINGS.
VERIFY FIELD CONDITIONS PRIOR TO START OF
CONSTRUCTION.
2. THE SCOPE OF THIS PROJECT IS LIMITED TO MECHANICAL
ROOMS EXCEPT FOR CONDUIT AND WIRING REQUIRED
THAT WILL BE RUN IN CORRIDORS. THE BUILDING WILL BE
OCCUPIED DURING CONSTRUCTION AND ALL SYSTEMS
MUST REMAIN OPERATIONAL.
3. CEILINGS IN MECHANICAL SPACES ARE OPEN TO
STRUCTURE BUT AVAILABLE SPACE IS LIMITED DUE TO
CONGESTION OF EXISTING SYSTEMS. CORRIDORS AND
OCCUPIED SPACES HAVE HARD CEILINGS.
4. CONTRACTOR RESPONSIBLE FOR PATCHING AND
PAINTING TO MATCH EXISTING CONDITIONS IF DAMAGED
DURING CONSTRUCTION.
KEY NOTES:
EXISTING EXHAUST LOUVER
EXISTING OUTSIDE AIR LOUVER
M E
C H
A N
I C
A L
G
R O
U N
D
F L O
R
P
A
M-101-H1
10"Ø SA
DH-H1-2
AC-H1-2
G20H
MECHANICAL
ROOM
SMALL
G21H
GENERAL
STORAGE
10"Ø RA
FD
MD
DH-H1-1
10"Ø SA
Ø
R A
AC-H1-1
EF-H1-1
x
10"x10"
G02H
MECHANICAL
ROOM
LARGE
14"x12" x
EXISTING
CHILLER
EXISTING
PUMPS
x
FD
14"x12"
1 2 3 4 5
A
B
C
D
D W
N
B
Y
C K
D
B
Y
S U
B M
I T
T E
D
B
Y
D A
T E
SHEET
IDENTIFICATION
D E
S I G
N E
D
B
Y
F I L
E
N
A M
E
P a r k w a y
L a n e
S u i t e
N o r c r o s s
G
A
P h o n e
F a x
P L
T
E
S I Z
E
A R
O
L I C
I T
A T
I O
N
N
O
C O
N T
R A
F I L
E
N
O
A P
P R
D
A T
E D
E S
C R
I P
T I O
N M
A R
K
U S
F
I S
H
A
L
D L
I F
E
N C
M
P U
S
D
I S
T R
I C
T
S H
E P
H E
R D
S T
O W
N
W
V
D E
H U
M I D
I F
I C
A T
I O
N
S
Y S
T E
M
F
O R
L O
D G
E
A
L D
O
L
E O
P O
S H
E P
H E
R D
S T
O W
N
W
E S
T
V
I R
G I N
I A
J O
B
N
O
100% DESIGN SUBMISSION
D W
E
D W
E M
I Z
E S
A
GENERAL NOTES:
1. DRAWINGS ARE BASED OFF OF AS-BUILT DRAWINGS.
VERIFY ACTUAL FIELD CONDITIONS PRIOR TO START OF
CONSTRUCTION.
2. THE SCOPE OF THIS PROJECT IS LIMITED TO MECHANICAL
ROOMS EXCEPT FOR CONDUIT AND WIRING REQUIRED
THAT WILL BE RUN IN CORRIDORS.THE BUILDING WILL BE
OCCUPIED DURING CONSTRUCTION AND ALL SYSTEMS
MUST REMAIN OPERATIONAL.
3. INSTALL DEHUMIDIFIERS IN LOCATION WHERE BOTTOM OF
UNIT IS AT LEAST 72" AFF, THERE IS MANUFACTURER'S
REQUIRED CLEARANCES, AND AT LEAST EIGHT DUCT
DIAMETERS BETWEEN UNIT AND DUCT TAP.
4. INSTALL DUCT TAPS ON OUTSIDE AIR DUCTWORK
UPSTREAM OF OUTSIDE AIR DAMPER.
5. EXISTING BUILDING SYSTEMS ARE SHOWN IN LIGHTER
LINE WEIGHT. DARKER LINE WEIGHTS SHOW NEW WORK
THAT IS COVERED UNDER THIS PROJECT.
SCALE: 1/4" = 1'-0"
4 0 4 8
KEY NOTES:
EXISTING EXHAUST LOUVER
EXISTING OUTSIDE AIR LOUVER
UTILIZE SPACE ABOVE DOORS TO
PENETRATE WALL. INSTALL 10" x 10", TYPE B
DYNAMIC FIRE DAMPER RATED FOR 3 HOURS.
INSTALL 20" x 12", TYPE B DYNAMIC FIRE
DAMPER RATED FOR 3 HOURS IN CONCRETE
WALL. INSTALL 1/2" x 1/2" WIRE MESH ON
ENDS OF WALL SLEEVE. INSTALL DAMPER A
MINIMUM OF 72" AFF IN A LOCATION TO
MITIGATE RELOCATING ANY EXISTING
UTILITIES.
INSTALL STAINLESS STEEL DEFLECTOR TO
HELP DISSIPATE EXHAUST AIR. REFER TO
DETAIL B4/M-501-H1.
DISCONNECT EXISTING EXHAUST FAN AND
ASSOCIATED APPURTENANCES/DUCTWORK
TO THE EXTENT INDICATED. COORDINATE
WITH ELECTRICAL ON DEMOLITION OF
CIRCUIT AND RESPECTIVE CONDUIT.
ROUTE FULL CONNECTION SIZE
CONDENSATE LINE TO EXISTING FLOOR
DRAIN IN MECHANICAL ROOM.
INSTALL 1/2" x 1/2" WIRE MESH OVER
OPENING AND BALANCE TO 150 CFM.
INSTALL 1/2" x 1/2" WIRE MESH OVER
OPENING AND BALANCE TO 1000 CFM.
INSTALL NEW EF-H1-1 PER MANUFACTURER'S
RECOMMENDATIONS.
INSTALL NEW DH-H1-1 PER MANUFACTURER'S
RECOMMENDATIONS.
INSTALL NEW DH-H1-2 PER MANUFACTURER'S
RECOMMENDATIONS.
EXISTING MD IS TO BE REPLACED WITH NEW
MD IN LOCATION INDICATED. EXISTING
CONTROL SEQUENCE IS TO REMAIN IN
EFFECT FOR THE DETERMINATION OF WHICH
DAMPER IS TO BE OPEN.
EXISTING VERTICAL DUCT AND MD TO
REMAIN. EXISTING GRILLE IN VERTICAL IS TO
BE BALANCED TO 1000 CFM AND MD IS
NORMALLY CLOSED.
BALANCE AC-H1-2 FOR 680 CFM OUTSIDE AIR,
1600 CFM RETURN AIR, AND 2200 CFM
SUPPLY.
M E
C H
A N
I C
A L
E
N L A
R G
E D
F L O
A
N S
SCALE:
A1
H1 (ALDO LEOPOLD) - GROUND FLOOR
1/4" = 1'-0" SCALE:
A3
H1 (ALDO LEOPOLD) - GROUND FLOOR
1/4" = 1'-0"
C4
M-401-H1
C2
A2
A4
A3
PHOTO KEY LEGEND
DIRECTION PHOTO WAS TAKEN
DENOTES PHOTO LOCATION
PHOTO REFERENCE NUMBER
SEE DRAWING
A1
M-901-H1
AIR FLOW
SPRING VIBRATION
ISOLATORS
PROVIDE BELT GUARD
DESIGNER NOTE: REMOVE
BELT GUARD WHEN USING
DIRECT DRIVE FAN.
FLEX CONNECTION
ALL THREAD
SUPPORT
FILTER
SUPPORT FROM STRUCTURE
W/ SPRING & NEOPRENE TYPE
VIBRATION ISOLATORS AND
3/8" HANGER RODS
PUMP
FAN
NOTES:
1. ALL VALVES, PIPING, AND EQUIPMENT SHOWN TO BE LOCATED INSIDE FAN COIL UNIT
CABINET WITH ACCESS FROM BELOW UNIT.
ELEVATION VIEW
PLAN VIEW
ROUTE CONDENSATE
DRAIN TO NEAREST
APPROVED FLOOR
DRAIN
EVAPORATOR COIL
INSULATED CONDENSATE PAN
DESICCANT WHEELSPLIT CONDENSING COILS
FLEXIBLE
CONNECTION, TYP.
10"Ø RETURN AIR DUCT
(REFER TO HVAC PLAN)
10"Ø SUPPLY AIR DUCT
(REFER TO HVAC PLAN)
FLEXIBLE
CONNECTION, TYP.
NOTES:
1. FIRE DAMPER RATING SHALL MEET OR EXCEED THE FIRE-RATING OF THE
BARRIER IN WHICH IT IS INSTALLED, 1 1/2 HR MINIMUM RATING.
2. PROVIDE FIRE DAMPER FOR ROUND DUCT OR USE TRANSITIONS FOR
ROUND TO SQUARE DUCT.
3. STATIC FIRE DAMPERS ARE PREFERRED IN SYSTEMS WHERE FANS
AUTOMATICALLY TURN OFF IN CASE OF FIRE. DYNAMIC FIRE DAMPERS ARE
REQUIRED IN ANY SYSTEM WHERE FANS ARE NOT AUTOMATICALLY
STOPPED IN CASE OF FIRE. WHERE ACCESSIBILITY IS EXTREMELY LIMITED,
MULTI-BLADE OR MOTOR-OPERATED FIRE DAMPERS SHALL BE USED.
12" INTEGRAL WALL SLEEVE BY FIRE
DAMPER MANUFACTURER, SLEEVE TO BE
18 GA MIN. WITH 3/16" EXPANSION CRACK
ON THREE SIDES BETWEEN SLEEVE AND
STRUCTURE, SEAL EXPANSION JOINT
WITH FIRE RETARDANT NON-HARDENING
MASTIC
INSULATED
ACCESS DOOR
CONCRETE WALL
RETAINING ANGLES
ALL FOUR SIDES,
RETAINING ANGLES BY
FIRE DAMPER
MANUFACTURER
STRAP FASTENING TO
ALLOW MANUAL
TESTING OF DAMPER
STRAP FASTENING TO
BE ACCESSIBLE THRU
ACCESS PANEL
CURTAIN TYPE OUT
OF THE AIR STREAM
FIRE DAMPER
BREAKAWAY JOINT (TYP)
WALL SLEEVE
A+2"
DRAIN PAN
A = TOTAL STATIC
PRESSURE
NOTE:
1. SEE MECHANICAL PIPING SCHEDULE FOR ACCEPTABLE MATERIALS.
2. SECURE PIPE TO STRUCTURE OR WALL.
FLOOR DRAIN
TERMINATE WITH 3"
AIR GAP AT FLOOR
DRAIN
SLOPE TOWARDS
FLOOR DRAIN
THREADED PLUG
UNION
TYPE "L" COPPER
IN PLENUMS
H
RADIUS = H, MINIMUM
CURVED ELBOW
CONVERGING AND DIVERGING DUCT TRANSITION
UNLESS NOTED OTHERWISE ON
PLANS, ANGLES SHOWN SHALL APPLY
TRANSITION AT EQUIPMENT
15° MAXIMUM
15° MAXIMUM
30° MAXIMUM
30° MAXIMUM
20° MAXIMUM
20° MAXIMUM
RECTANGULAR DUCT HANGER DETAIL
ANGLE PER SMACNA
NUTS
THREADED ROD PER
SMACNA, MIN. 3/8"
NOTES:
1. TABULATED DATA FROM SMACNA ALLOWS FOR DUCT REINFORCING
AND INSULATION, BUT NO EXTERNAL LOAD.
2. PROVIDE HIGH DENSITY INSERT AT TRAPEZE FOR INSULATED
DUCTS.
3. HANGERS SHALL NOT BE HUNG DIRECTLY FROM ROOF DECK. ALL
HANGERS SHALL BE HUNG FROM SUPPORTING STRUCTURAL
FEATURES ONLY. BUILD TRAPEZES AS NECESSARY.
4. ALL RECTANGULAR DUCT MUST BE HUNG USING THIS METHOD.
METAL STRAPPING SCREWED INTO THE DUCT WILL NOT BE
ACCEPTED .
3" MIN.
L
1 2 3 4 5
A
B
C
D
D W
N
B
Y
C K
D
B
Y
S U
B M
I T
T E
D
B
Y
D A
T E
SHEET
IDENTIFICATION
D E
S I G
N E
D
B
Y
F I L
E
N
A M
E
P a r k w a y
L a n e
S u i t e
N o r c r o s s
G
A
P h o n e
F a x
P L
T
E
S I Z
E
A R
O
L I C
I T
A T
I O
N
N
O
C O
N T
R A
F I L
E
N
O
A P
P R
D
A T
E D
E S
C R
I P
T I O
N M
A R
K
U S
F
I S
H
A
L
D L
I F
E
N C
M
P U
S
D
I S
T R
I C
T
S H
E P
H E
R D
S T
O W
N
W
V
D E
H U
M I D
I F
I C
A T
I O
N
S
Y S
T E
M
F
O R
L O
D G
E
A
L D
O
L
E O
P O
S H
E P
H E
R D
S T
O W
N
W
E S
T
V
I R
G I N
I A
J O
B
N
O
100% DESIGN SUBMISSION
D
W E
D W
E
M I Z
E S
A
M E
C H
A N
I C
A L
D
E T
A I L S
SCALE:
A3
DEHUMIDIFICATION UNIT DETAIL
N.T.S.
SCALE:
B1
INLINE EXHAUST FAN DETAIL
N.T.S. SCALE:
B4
EXHAUST DEFLECTOR DETAIL
N.T.S.
NOTES:
1. DEFLECTORS SHALL BE 316 SS, 18 GA MINIMUM.
2. SECURE DEFLECTORS WITH STAINLESS STEEL NO. 10 x 1" SELF DRIVING HEX
WASHER HEAD SCREWS, HEAD SIZE 5/16", PLACED EVERY 4".
3. DEFLECTORS PURPOSE IS TO HELP DISSIPATE ODORS FROM NEW TANK
ROOM EXHAUST.
4. DEFLECTORS SHALL HAVE SAME FREE AREA AS LOUVER.
16"
FULL LENGTH OF
LOUVER HEIGHT
EXISTING
LOUVER
NEW
DEFLECTOR
NEW
DEFLECTOR
M-501-H1
SCALE:
A4
VERTICAL FIRE DAMPER DETAIL
N.T.S.
ELEVATION VIEW PLAN VIEW
SCALE:
D1
CONDENSATE DRAIN DETAIL
N.T.S.
SCALE:
C3
TYPICAL DUCT TRANSITIONS
N.T.S.SCALE:
C2
RECTANGULAR DUCT HANGER DETAIL
N.T.S.
SCALE:
A1
TRANSFER DUCT DETAIL
N.T.S.
12"
DDC INPUT OUTPUT SUMMARY
Y
S T
G
A
P H
S
P L A
Y
OUTPUTS INPUTS
SOFTWARE
REMARKS
DIGITAL ANALOG DIGITAL ANALOG
POINT NAME POINT DESCRIPTION
S T
A R
T S
T O
P
O P
E N
C
L O
S E
E N
A B
L E
D
I S
A B
L E
S E
T P
O I N
T
A
D J U
S T
P O
S I T
I O
N
V A
L V
E
C
O M
M A
N D
S P
E E
D
C
O N
T R
O L
C U
R R
E N
T
S
E N
S I N
G
R
E L A
Y
D I F
F E
R E
N T
I A
L
P
R E
S S
U R
E
S
W I T
C H
S T
A R
T S
T O
P
F L O
W
S
W I T
C H
O P
E N
C
L O
S E
A L A
R M
P U
B
U T
T O
N
O
V E
R R
I D
E
P U
L S
E
C
O N
T A
C T
T E
M P
E R
A T
U R
E
E L E
C T
R I C
A L
D
E M
A N
D k W
A M
P E
R A
G E
V F
D
F
R E
Q U
E N
Y
P R
E S
S U
R E
C A
R B
O
X I D
E
P O
S I T
I O
N
F L O
W
E N
T H
A L P
Y
H U
M I D
I T
Y
A N
A L O
G
V
A R
I A
B L E
B I N
A R
Y
V
A R
I A
B L E
S O
F
A
R M
R U
N T
I M
E
T
O T
A L I Z
A T
I O
N
R E
S E
T
A
V A
I L A
B L E
S C
H E
D U
L E
C A
L C
U L A
T E
D
P
O I N
T
DH-n-SS DESICCANT UNIT START/STOP X
OA-T OTUSIDE AIR TEMPERATURE X X
OA-RH OUTSIDE AIR RELATIVE HUMIDITY X X
X
NOTE: OUTSIDE AIR DRY-BULB TEMPERATURE SENSOR AND RELATIVE
HUMIDITY SENSOR ARE TO BE LOCATED IN OUTSIDE AIR DUCT UPSTREAM OF
THE DESICCANT UNIT AND DOWNSTREAM OF OUTSIDE AIR INTAKE LOUVER.
ACTIVE DESICCANT DEHUMIDIFIER UNIT
MARK MANUFACTURER MODEL # LOCATION ASSOCIATED
AHU
SUPPLY FAN CAPACITY LB/HR
(80 °F/60% RH)
COMPRESSOR TON SIZE (WXLXH) IN WEIGHT lbs ELECTRICAL NOTES
PROCESS CFM ESP IN WG MHP VOLTAGE PHASE FREQUENCY FLA
DH-H1-1 NOVELAIRE 600 DES/DX CR
G02H LARGE
MECH ROOM
AC-H1-1 680 0.6" 1.5 13.8 2 42.3"X58.3"X17.8" 395 208-230 1 60 19.1 1 - 4
DH-H1-2 NOVELAIRE 600 DES/DX CR
G20H SMALL
MECH ROOM
AC-H1-2 680 0.6" 1.5 13.8 2 42.3"X58.3"X17.8" 395 208-230 1 60 19.1 1 - 4
EXHAUST FAN SCHEDULE
Mark LOCATION SERVICE TYPE CFM
MINIMUM ESP
(IN. WG.)
DRIVE VFD
MOTOR
HP
BRAKE
HP
FAN DATA
BASIS OF DESIGN NOTES
VOLTS PHASE
EF-H1-1 G02H LARGE MECH ROOM FUEL OIL TANK EXHAUST INLINE 1,150 1 BELT NO - 115 1 GREENHECK QEI-9-II-7 1 - 8
NOTES:
1. FAN SPEED CONTROLLER PROVIDED BY MECHANICAL AND INSTALLED BY ELECTRICAL
2. DISCONNECT TO BE PROVIDED AND INSTALLED BY ELECTRICAL
3. NEMA PREMIUM MOTORS
4. PROVIDE WALL HOUSING WITH OSHA GUARD
5. TYPE B SPARK RESISTANT CONSTRUCTION
6. PROVIDE BACKDRAFT DAMPER
7. PROVIDE STARTER
8. FANS ARE TO RUN 24/7 FOR CONSTANT EXHAUST.
3/4
1 2 3 4 5
A
B
C
D
D W
N
B
Y
C K
D
B
Y
S U
B M
I T
T E
D
B
Y
D A
T E
SHEET
IDENTIFICATION
D E
S I G
N E
D
B
Y
F I L
E
N
A M
E
P a r k w a y
L a n e
S u i t e
N o r c r o s s
G
A
P h o n e
F a x
P L
T
E
S I Z
E
A R
O
L I C
I T
A T
I O
N
N
O
C O
N T
R A
F I L
E
N
O
A P
P R
D
A T
E D
E S
C R
I P
T I O
N M
A R
K
U S
F
I S
H
A
L
D L
I F
E
N C
M
P U
S
D
I S
T R
I C
T
S H
E P
H E
R D
S T
O W
N
W
V
D E
H U
M I D
I F
I C
A T
I O
N
S
Y S
T E
M
F
O R
L O
D G
E
A
L D
O
L
E O
P O
S H
E P
H E
R D
S T
O W
N
W
E S
T
V
I R
G I N
I A
J O
B
N
O
100% DESIGN SUBMISSION
D W
E
D W
E M
I Z
E S
A
M E
C H
A N
I C
A L
S
C H
E D
U L E
S
M-601-H1
NOTES:
1. DISCONNECT TO BE PROVIDED AND INSTALLED BY ELECTRICAL.
2. PROVIDE STARTER FOR SINGLE-POWER POINT CONNECTION.
3. DEHUMIDIFIER SHALL ENERGIZE ANYTIME RESPECTIVE AIR HANDLER IS RUNNING.
4. DEHUMIDIFIERS ONLY NEED READ-ONLY POINTS ON THE CONTROL FRONT END.
POINTS SHALL BE FOR FAN STATUS AND ALARM IF RESPECTIVE AIR HANDLER IS
RUNNING AND DEHUMIDIFIER IS NOT.
SCALE:
B3
ACTIVE DESICCANT DEHUMIDIFIER (DH) POINTS LIST
M-901-H1
1 2 3 4 5
A
B
C
D
D W
N
B
Y
C K
D
B
Y
S U
B M
I T
T E
D
B
Y
D A
T E
SHEET
IDENTIFICATION
D E
S I G
N E
D
B
Y
F I L
E
N
A M
E
P a r k w a y
L a n e
S u i t e
N o r c r o s s
G
A
P h o n e
F a x
P L
T
E
S I Z
E
A R
O
L I C
I T
A T
I O
N
N
O
C O
N T
R A
F I L
E
N
O
A P
P R
D
A T
E D
E S
C R
I P
T I O
N M
A R
K
U S
F
I S
H
A
L
D L
I F
E
N C
M
P U
S
D
I S
T R
I C
T
S H
E P
H E
R D
S T
O W
N
W
V
D E
H U
M I D
I F
I C
A T
I O
N
S
Y S
T E
M
F
O R
L O
D G
E
A
L D
O
L
E O
P O
S H
E P
H E
R D
S T
O W
N
W
E S
T
V
I R
G I N
I A
J O
B
N
O
100% DESIGN SUBMISSION
D W
E
D W
E M
I Z
E S
A
M E
C H
A N
I C
A L
P
H O
T O
S
SCALE:
A4
LARGE MECH ROOM
N.T.S.
SCALE:
C2
ELECT ROOM
N.T.S.
SCALE:
A2
MECH ROOM 2
N.T.S. SCALE:
A3
MECH ROOM 3
N.T.S.
SCALE:
C4
TANK ROOM
N.T.S.
GENERAL NOTES:
1. MECHANICAL ROOM CEILING SPACE IS
CONGESTED. LOCATE DEHUMIDIFIERS IN
A LOCATION WHERE THEY CAN BE
MAINTAINED, ARE AT LEAST 72" AFF, AND
HAVE AT LEAST EIGHT DUCT DIAMETERS
BETWEEN UNIT AND DUCT TAPS TO
EXISTING OUTSIDE AIR DUCT.
2. ALL WALLS INTO TANK ROOM ARE
CONCRETE AND OPENINGS FOR NEW
DUCT AND TRANSFER SLEEVE WILL
NEED TO BE CUT INTO WALL.
E-001-H1
S
A
T E
H
T E
H
E L
E C
T R
I C
M
B O
L S
S C
M
GENERAL NOTES:
THE WORK SHALL CONFORM WITH ALL REQUIREMENTS OF:
(A) NFPA 70-2014 (NATIONAL ELECTRICAL CODE)
(B) NESC 2015 (NATIONAL ELECTRICAL SAFETY CODE)
(C) APPLICABLE LOCAL CODES AND FEDERAL AND STATE LAWS.
MINIMUM ELECTRICAL RACEWAY SIZE SHALL BE 3/4". MINIMUM TELECOMMUNICATIONS
RACEWAY SIZE SHALL BE 1". INCREASE RACEWAY SIZE AS REQUIRED TO LIMIT RACEWAY FILL
RATIO TO LESS THAN 40% FULL.
CONTRACTOR SHALL CAREFULLY COORDINATE WORK WITH ALL TRADES AND SHALL BE
RESPONSIBLE FOR SECURING SPACE REQUIREMENTS FOR ELECTRICAL EQUIPMENT
CLEARANCE FOR RECESSED LIGHTING FIXTURES AND CORRECT ROUGH-IN LOCATIONS OF
ELECTRICAL CONNECTIONS.
CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING CATALOG NUMBERS ON THESE
DRAWINGS TO MATCH WITH MATERIAL DESCRIPTIONS INDICATED.
VERIFY DOOR SWINGS WITH ARCHITECTURAL DRAWINGS BEFORE ROUGHING IN WALL
SWITCHES. SWITCHES IN THE SAME LOCATION SHALL BE GANGED TOGETHER IN ONE
COMMON BACKBOX AND SHALL HAVE ONE COMMON FACE PLATE.
ALL FEEDERS AND BRANCH CIRCUITS SHALL INCLUDE A GREEN INSULATED GROUND
CONDUCTOR, SIZE PER NATIONAL ELECTRICAL CODE, OR AS SHOWN, CONNECTED TO EACH
DEVICE AND OUTLET BOX ON THE CIRCUIT AND TO THE PANELBOARD GROUND BUS
MULTIPLE BRANCH CIRCUITS IN ONE RACEWAY REQUIRE ONLY ONE GROUND CONDUCTOR.
VERIFY LUMINAIRE, CEILING MOUNTED SMOKE DETECTOR LOCATIONS WITH ARCHITECTURAL
REFLECTED CEILING PLANS FOR EXACT LOCATIONS AND DIMENSIONS PRIOR TO
INSTALLATION. VERIFY EXACT LOCATIONS OF MOTORS AND EQUIPMENT BEFORE
ROUGHING-IN.
EXISTING ELECTRICAL WORK (NOT SHOWN) SHALL REMAIN, UNLESS INDICATED OTHERWISE.
SHOULD ANY EXISTING ELECTRICAL POWER, LIGHTING OR AUXILIARY CIRCUIT, FEEDER OR
EQUIPMENT BE SEVERED, DISCONNECTED OR DELETED IN THE PROCESS OF
CONSTRUCTION OR REMODELING WHICH IS DONE AS A RESULT OF CONTRACT PLANS AND
SPECIFICATIONS, AND UNLESS SPECIFICALLY DESIGNATED BY THE DRAWINGS TO BE
DELETED, THEN SAID CIRCUIT OR FEEDER SHALL BE RESTORED TO WORKING CONDITION.
THE RESTORATION SHALL INCLUDE RE-ROUTING, RELOCATION, RECONNECTION OR
REPLACEMENT AS MAY BE REQUIRED BY THE NEW WORK. ANY SUCH WORK REQUIRED
SHALL BE INCLUDED IN THE CONTRACT AND NO EXTRA COMPENSATION WILL BE GRANTED.
NEW WORK SHALL BE MADE TO TIE INTO THE EXISTING IN A UNIFORM MANNER, SIMILAR
ITEMS OF NEW WORK SHALL BE CHECKED AGAINST EXISTING WORK FOR TYPE MOUNTING,
MOUNTING HEIGHTS, ETC. ITEMS SHOWN IN NEW WORK AT VARIANCE FROM THE EXISTING
SHALL BE REFERRED TO THE CONTRACTING OFFICER FOR DECISION BEFORE ROUGH-IN.
1.
2.
3.
4.
5.
6.
7.
8.
9.
ABBREVIATIONS
A OR AMP
ACC
AHU
AIC
AWG
BCW
BFF
BFG
BLDG
CB
CH
CKT
CU
DISC
EF
ELEC
E or EMER
EQUIP
EXIST or EX
FWE
G OR GND
GFGI
GFI
H or HT
HP
HZ
KAIC
KCM OR KCMIL
KVA
KW
AMPERE(S)
AIR COOLED CHILLER
AIR HANDLING UNIT
AMPERE INTERRUPTING CAPACITY
AMERICAN WIRE GAUGE
BARE COPPER WIRE
BELOW FINISHED FLOOR
BELOW FINISHED GRADE
BUILDING
CONDUIT
CIRCUIT BREAKER
CHILLER
CIRCUIT
COPPER OR CONDENSING UNIT
DEPTH
DISCONNECT SWITCH
DEHUMIDIFIER
EXHAUST FAN
ELECTRICAL
EMERGENCY
EQUIPMENT
EXISTING
FUSE
FURNISHED WITH EQUIPMENT
GROUND
GOVERNMENT FURNISHED GOVERNMENT INSTALLED
GROUND FAULT INTERRUPTER
HEIGHT
HORSE POWER
HERTZ
KILO
THOUSAND AMPERE INTERRUPTING CAPACITY
THOUSAND OF CIRCULAR MILS
KILOVOLT
KILOVOLT-AMPERES
KILOWATT
L
MAX
MCA
MCB or MB
MGB
MIN
MLO
MRS
N
NEC
NEMA
NESC
NTS
P
PDU
PF
PH
PMT
PNL
RECEPT or RECP
SCCR
SF
SPD
SPEC
SQ
SWBD
SWGR
TYP
UH
UIO
V
VA
W
WP
XFMR
LENGTH
MAXIMUM
MINIMUM CIRCUIT AMPACITY
MAIN CIRCUIT BREAKER
MAIN GROUND BAR
MINIMUM
MAIN LUGS ONLY
MOTOR RATED SWITCH
NEUTRAL
NATIONAL ELECTRICAL CODE
NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION
NATIONAL ELECTRICAL SAFETY CODE
NOT TO SCALE
POLE(S) or PUMP
POWER DISTRIBUTION UNIT
POWER FACTOR
PHASE
PAD MOUNTED TRANSFORMER
PANEL or PANLEBOARD
RECEPTACLE
SHORT CIRCUIT CURRENT RATING
SUPPLY FAN
SURGE PROTECTIVE DEVICE
SPECIFICATIONS
SQUARE
SWITCHBOARD
SWITCHGEAR
TYPICAL
UNIT HEATER
UNLESS INDICATED OTHERWISE
VOLTS
VOLT AMPERES
WATTS or WIRE or WIDTH
WEATHERPROOF
TRANSFORMER
K
F
D
C
PANELBOARD, SEE SCHEDULES
EQUIPMENT AS INDICATED
DISTRIBUTION PANELBOARD
EQUIPMENT
SYMBOL DESCRIPTION
KV
1 2 3 4 5
A
B
C
D
D W
N
B
Y
C K
D
B
Y
S U
B M
I T
T E
D
B
Y
D A
T E
SHEET
IDENTIFICATION
D E
S I G
N E
D
B
Y
F I
M
E
P a r k w a y
L a n e
S u i t e
N o r c r o s s
G
A
P h o n e
F a x
P L O
T
S
C A
L E
P
L O
T
D
A T
E
S I Z
E
A R
O
L I C
I T
A T
I O
N
N
O
C O
N T
R A
F I
D I C
T D
A P
P R
D
A T
E D
E S
C R
I P
T I O
N M
A R
K
U S
F
I S
H
A
L D
L I F
E
N C
M
P U
S
D
I S
T R
I C
T
S H
E P
H E
R D
S T
O W
N
W
V
D E
H U
M I D
I F
I C
A T
I O
N
S
Y S
T E
M
F
O R
L O
D G
E
A
L D
O
L
E O
P O
S H
E P
H E
R D
S T
O W
N
W
E S
T
V
I R
G I N
I A
J O
B
N
O
100% DESIGN SUBMISSION
DH
MOTOR RATED SWITCH
DISCONNECT SWITCH
M
S
MOTOR OPERATED DAMPER
MD
DH-H1-2
DH-H1-1
EF-H1-1
H1-R-1
M
D
M
S
N
E-101-H1
E S
A
T E
H
T E
H
G R
O U
O
O R
E L
E C
T R
I C
R
T
P
L A
N S
S C
M
SCALE:
SCALE: 1/4" = 1'-0"
4 0 4 8
A1
ELECTRICAL - PART PLAN
1/4" = 1'-0"
SCALE:
A3
ELECTRICAL - PART PLAN
1/4" = 1'-0"
GENERAL NOTES:
1. REFER TO E-001 FOR GENERAL NOTES,
ABBREVIATIONS AND SYMBOLS.
2. REFER TO E-601 FOR MECHANICAL
EQUIPMENT CONNECTION SCHEDULE
FOR DISCONNECT AND FEEDER SIZES.
1 2 3 4 5
A
B
C
D
D W
N
B
Y
C K
D
B
Y
S U
B M
I T
T E
D
B
Y
D A
T E
SHEET
IDENTIFICATION
D E
S I G
N E
D
B
Y
F I
M
E
P a r k w a y
L a n e
S u i t e
N o r c r o s s
G
A
P h o n e
F a x
P L O
T
S
C A
L E
P
L O
T
D
A T
E
S I Z
E
A R
O
L I C
I T
A T
I O
N
N
O
C O
N T
R A
F I
D I C
T D
A P
P R
D
A T
E D
E S
C R
I P
T I O
N M
A R
K
U S
F
I S
H
A
L D
L I F
E
N C
M
P U
S
D
I S
T R
I C
T
S H
E P
H E
R D
S T
O W
N
W
V
D E
H U
M I D
I F
I C
A T
I O
N
S
Y S
T E
M
F
O R
L O
D G
E
A
L D
O
L
E O
P O
S H
E P
H E
R D
S T
O W
N
W
E S
T
V
I R
G I N
I A
J O
B
N
O
100% DESIGN SUBMISSION
H1-R-1-25,27
H1-R-1-21,23
H1-R-1-18
KEY NOTES:
EXISTING EXHAUST FAN TO BE DEMOLISHED.
DEMOLISH CONDUIT AND CONDUCTORS
BACK TO SOURCE.
PROVIDE 120V/1PH POWER FOR MOTOR
OPERATED DAMPER.
H1-R-1-10
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text G22H
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text G31H
AutoCAD SHX Text
LINK A
AutoCAD SHX Text G21H
AutoCAD SHX Text
GEN STOR
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text G04H
AutoCAD SHX Text
BOILER RM
AutoCAD SHX Text G02H
AutoCAD SHX Text
MECH RM
AutoCAD SHX Text G06H
AutoCAD SHX Text
TANK RM
AutoCAD SHX Text G08H
AutoCAD SHX Text
ELECT RM
AutoCAD SHX Text
AIR INTAKE SHAFT
AutoCAD SHX Text G33H
AutoCAD SHX Text
LINK B
AutoCAD SHX Text G12H
AutoCAD SHX Text G10H
AutoCAD SHX Text
STOR
AutoCAD SHX Text G34H
AutoCAD SHX Text
CORRIDOR 3
AutoCAD SHX Text
ELEC
E-601-H1
S
A
T E
H
T E
H
E L
E C
T R
I C
N
E L
S C
H E
D U
L E
S
S C
M
UNIT
DH-H1-1
DH-H1-2
EF-H1-1
NOTES: 1.
VOLTAGE
COORDINATE DISCONNECT LOCATION WITH EXISTING EQUIPMENT TO PROVIDE N.E.C. REQUIRED WORKING CLEARANCES.
PHASE
MECHANICAL EQUIPMENT CONNECTION SCHEDULE
KVA FLA
19.1
19.1
13.8
HP
1.5
1.5
3/4
DISCONNECT
30/NF/1/1
FEEDER SIZE
2#10+1#10G,3/4"C
PANEL CIRCUIT NOTES
30/NF/2/1
30/NF/2/1 2#10+1#10G,3/4"C
2#12+1#12G,3/4"C
1,2
1,2
1,2
1 20A ELEVATOR CONTROLS RECEPTACLES 20A 2
3 - - B-H2-1 20A 4
5 - - B-H2-1 20A 6
7 20A RECEPTACLES P-H1-3 20A 8
9 20A SUMP PUMP EF-H1-2 20A 10
11 20A RECEPTS FASP 20A 12
13 20A P-H1-4 & RECEPTS FASP 20A 14
15 20A EXT. LIGHT FIXTURES LIGHTING 20A 16
17 20A UHS & RECEPTS SPARE 20A 18
19 20A SPARE SPARE 20A 20
21 20A SPARE SPARE 15A 22
23 20A SPARE SPARE 15A 24
25 20A SPARE ELEVATOR 20A 26
27 20A SPARE - - 28
29 20A SPARE - - 30
MINIMUM BREAKER S.C.C.R.: 10,000
NOTES:
TOTAL CONNECTED LOAD:
Ø BØ A Ø C
CONNECTED LOAD KVA
0.5 0.94
0.5 1.80
0.5 1.80
1.650.96
1.200.5
0.92 0.2
0.21.24
1.730.3
1.32
45.1A
H1-R-1 (EXISTING)
225A MCB VOLTAGE: MOUNTING:WIRE:PHASE:208/120V. 3Ø 4W. SURFACE
CIR.
NO.
TRIP
POLE POLE
TRIP
CIR.
NO.
NEMA 1 ENCLOSURE
DESCRIPTION DESCRIPTION
1 20A ELEVATOR CONTROLS RECEPTACLES 20A 2
3 - - B-H2-1 20A 4
5 - - B-H2-1 20A 6
7 20A RECEPTACLES P-H1-3 20A 8
9 20A SUMP PUMP MOD 20A 10**
11 20A RECEPTS FASP 20A 12
13 20A P-H1-4 & RECEPTS FASP 20A 14
15 20A EXT. LIGHT FIXTURES LIGHTING 20A 16
17 20A UHS & RECEPTS EF-H1-1 35A 18*
25A DH-H1-1
SPARE 20A 20
21*
SPARE 20A 22
23*
25A DH-H1-2
SPARE 20A 24
25*
SPARE 20A 26
27* SPARE 20A 28
29 20A SPARE SPARE 20A 30
31 - SPACE SPACE - 32
33 - SPACE SPACE - 34
35 - SPACE SPACE - 36
37 - SPACE SPACE - 38
39 - SPACE SPACE - 40
41 - SPACE SPACE - 42
MINIMUM BREAKER S.C.C.R.: 10,000
NOTES:
TOTAL CONNECTED LOAD:
B A C
CONNECTED LOAD KVA
0.50 0.94
0.50 1.80
0.50 1.80
1.650.96
.100.50
0.92 0.20
0.201.24
1.730.30
1.32 1.66
1.99
1.99
1.99
1.99
TOTAL A TOTAL B TOTAL C
7.48 8.91 8.39
68.78A
H1-R-1 (REVISED)
225A MCB VOLTAGE: MOUNTING:WIRE:PHASE:208/120V. 3 4W. SURFACE
CIR.
NO.
TRIP
POLE POLE
TRIP CIR.
NO.
NEMA 1 ENCLOSURE
DESCRIPTION DESCRIPTION
H1-R-1
H1-R-1
H1-R-1
21,23
25,27
1 2 3 4 5
A
B
C
D
D W
N
B
Y
C K
D
B
Y
S U
B M
I T
T E
D
B
Y
D A
T E
SHEET
IDENTIFICATION
D E
S I G
N E
D
B
Y
F I
M
E
P a r k w a y
L a n e
S u i t e
N o r c r o s s
G
A
P h o n e
F a x
P L O
T
S
C A
L E
P
L O
T
D
A T
E
S I Z
E
A R
O
L I C
I T
A T
I O
N
N
O
C O
N T
R A
F I
D I C
T D
A P
P R
D
A T
E D
E S
C R
I P
T I O
N M
A R
K
U S
F
I S
H
A
L D
L I F
E
N C
M
P U
S
D
I S
T R
I C
T
S H
E P
H E
R D
S T
O W
N
W
V
D E
H U
M I D
I F
I C
A T
I O
N
S
Y S
T E
M
F
O R
L O
D G
E
A
L D
O
L
E O
P O
S H
E P
H E
R D
S T
O W
N
W
E S
T
V
I R
G I N
I A
J O
B
N
O
100% DESIGN SUBMISSION
TOTAL ØATOTAL ØBTOTAL ØC
5.49 6.03 4.74
KEY NOTES:
MECHANICAL EQUIPMENT EF-H1-2 IS TO BE
DEMOLISHED. DEMOLISH CONDUIT AND
CONDUCTORS BACK TO SOURCE.
20A SPARE
*PROVIDE AND INSTALL NEW COMPATIBLE CIRCUIT BREAKER SIZED AS INDICATED.
NOTE ADDITION TO PANEL SCHEDULE.
**INDICATES NEW CIRCUIT FED FROM EXISTING SPARE BREAKER.
2. DISCONNECT PROVIDED BY DIVISION 26.
STARTER
FWE
FWE
C
SHEET NO.
G-001-H2
M-001-H2
M-002-H2
M-101-H2
M-401-H2
M-501-H2
B M-601-H2
M-901-H2
E-001-H2
E-101-H2
E-601-H2
A
2 3 4
SHEET INDEX
SHEET NAME
GENERAL
COVER SHEET & SHEET INDEX
MECHANICAL
MECHANICAL ABBREVIATIONS AND GENERAL NOTES
MECHANICAL LEGENDS
MECHANICAL GROUND FLOOR PLAN
MECHANICAL ENLARGED PLANS
MECHANICAL DETAILS
MECHANICAL SCHEDULES
MECHANICAL PHOTOS
ELECTRICAL
ELECTRICAL ABBREVIATIONS AND GENERAL NOTES
ELECTRICAL GROUND FLOOR PLAN
ELECTRICAL SCHEDULES
NATIONAL CONSERVATION TRAINING CENTER
SHEPHERDSTOWN, WEST VIRGINIA
AUGUST 17, 2017
ll
Knowledge Resoutces and rechnolog1es
Red
Lat
PROJECT SITE
West Pand (lff,ces
Cl:lmmd'es M&mmia/
Aldo leoptJld Lodge
Yellow
Lot
3500 Parkway Lane, Suite 500 Norcross, GA 30092 Phone(678)336-7740 Fax(678)336-7744
JOB NO. 1170656
Commons
Oil■
IWA,
4, CM!rnl
P/ar,t
� c:/Jei
Ca!S(Jn Lodge fhy:sicaJ fJsjning
100% DESIGN SUBMISSION
a.a.
L!J z a.
L!J d z d ,._ z � z ;::: 0� >' o5 i:: d 0 w 0 I- z
--' z 0 0
0 (/) . u ' ii: '
L!J s w w 0
L!J � < 0 < s (/) I-z
0 L!J 0 L!J 0 " --' --' u >' a.
0 u_j .
C :ii L!J --' 0 L!J
� I= <( I-z uo C
:ii rni5 .. I
U) z "'
1-Z L!JU
s o-L!J :::, --' "' t::! "' 0 0 (/) a.<( (/)<
SHEET
G-001-H2
GENERAL MECH. ABBREVIATIONS
@ AT
& AND
AFF ABOVE FINISHED FLOOR
A/C ABOVE CEILING
AD AUTOMATIC DAMPER
ADJ. ADJUSTABLE
AFMS AIRFLOW MEASURING STATION
AHU AIR HANDLING UNIT
ARCH ARCHITECTURAL OR ARCHITECT
AS AIR SEPARATOR
ASHRAE AMERICAN SOCIETY OF HEATING, REFRIGERATING
AND AIR CONDITIONING ENGINEERS
AUX. AUXILIARY
B BOILER
BD BACKDRAFT DAMPER
BLDG BUILDING
BFF, BFS BELOW FINISHED FLOOR, BELOW FINISHED SLAB
BTU, BTUh BRITISH THERMAL UNITS, BTUs PER HOUR
CAV CONSTANT AIR VOLUME
CCC CLOSED CIRCUIT COOLER
CD CONDENSATE DRAIN LINE
CFM CUBIC FEET PER MINUTE
CMU CONCRETE MASONRY UNIT
CO CLEANOUT
CO2 CARBON DIOXIDE
CONC CONCRETE
CONN. CONNECT, CONNECTING, CONNECTION
CONT. CONTINUED
COP COEFFICIENT OF PERFORMANCE
COR CONTRACTING OFFICER'S (OWNER'S)
REPRESENTATIVE
CU CONDENSING UNIT
CWR CONDENSER WATER RETURN
CWS CONDENSER WATER SUPPLY
D DEPTH
DB, Tdb DRY BULB (TEMPERATURE)
DbA DECIBELS
DDC DIRECT DIGITAL CONTROLS
DIA DIAMETER
DN DOWN
DP DEEP
dP, PD DELTA PRESSURE, PRESSURE DROP
DWG DRAWING
DX DIRECT EXPANSION
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
EER ENERGY EFFICIENCY RATIO
EF EXHAUST FAN
EFF EFFICIENCY
ELEC ELECTRICAL
EMCS ENERGY MONITORING AND CONTROL SYSTEM
ERU ENERGY RECOVERY UNIT
ET EXPANSION TANK
ESP EXTERNAL STATIC PRESSURE
EWT ENTERING WATER TEMPERATURE
EXT EXTERIOR
EXH EXHAUST
EXIST. EXISTING
DEG. F (°F) DEGREES FAHRENHEIT
FD FIRE DAMPER, FLOOR DRAIN
FFE FINISHED FLOOR ELEVATION
FLA FULL LOAD AMPS
FOB, FOT FLAT ON BOTTOM, FLAT ON TOP
FSD FIRE SMOKE DAMPER
FT FOOT OR FEET
FT. WG FEET WATER GAUGE
HP HEAT PUMP, HORSEPOWER
HR HOUR
HTG HEATING
HTR HEATER
HVAC HEATING, VENTILATING AND AIR
CONDITIONING
HZ
HERTZ
IN INCHE(S)
IN WC INCHES WATER COLUMN
IN WG INCHES WATER GAUGE
KW KILOWATTS
L LENGTH
LAT LEAVING AIR TEMPERATURE
LBS POUNDS
LBF/IN2 POUND FORCE PER SQUARE INCH
LWT LEAVING WATER TEMPERATURE
MAX MAXIMUM
MBH 1,000 x BTUs
MCA MINIMUM CIRCUIT AMPACITY
MD MOTORIZED DAMPER
MERV MINIMUM EFFICIENCY REPORTING VALUE
MECH MECHANICAL
MFR, MFG MANUFACTURER, MANUFACTURING
MIN MINIMUM
MOCP MAXIMUM OVER CURRENT PROTECTION
MTD MOUNTED
MUW MAKE UP WATER (DOMESTIC)
NO. NUMBER
NTS NOT TO SCALE
OA OUTSIDE AIR
OD OUTSIDE DIAMETER
GENERAL MECH. ABBREVIATIONS (CONT.)
PD PRESSURE DROP
PH PHASE
PPM PARTS PER MILLION
PRV PRESSURE RELIEF VALVE
QTY QUANTITY
RA RETURN AIR
RG RETURN GRILLE
RH RELATIVE HUMIDITY
RL REFRIGERANT LIQUID
RM ROOM
RPM REVOLUTIONS PER MINUTE,
ROTATIONS PER MINUTE
RS REFRIGERANT SUCTION
SA SUPPLY AIR
SD SMOKE DAMPER, SMOKE DETECTOR
SEER SEASONAL ENERGY EFFICIENCY RATIO
SF SUPPLY FAN
SMACNA SHEET METAL AND AIR CONDITIONING
CONTRACTORS' NATIONAL ASSOCIATION
SP STATIC PRESSURE
SS, SST STAINLESS STEEL
T'STAT THERMOSTAT
TEMP TEMPERATURE
THR TOTAL HEAT REJECTION
TYP TYPICAL
UH UNIT HEATER
V VOLTAGE
VAV VARIABLE AIR VOLUME
VD VOLUME DAMPER
VFD VARIABLE FREQUENCY DRIVE
VSD VARIABLE SPEED DRIVE
W WATT
W/ WITH
W/O WITHOUT
WB, Twb WET BULB (TEMPERATURE)
WD WIDE, WIDTH
WG WATER GAUGE
WWSP WATER WATER HEAT PUMP
MVD MANUAL VOLUME DAMPER
TG TRANSFER GRILLE
THA TOTAL HEAT ABSORPTION
HD HEAD
C CHILLER
PCF POUNDS PER CUBIC FOOT
MAU MAKEUP AIR UNIT
DCW DOMESTIC COLD WATER
FDB DEGREES FAHRENHEIT DRY BULB
FWB DEGREES FAHRENHEIT WET BULB
SB SECURITY BARS
E.W.T.& B. EACH WAY TOP & BOTTOM
Cv VALVE FLOW COEFFICIENT
CHWS CHILLED WATER SUPPLY
CHWR CHILLED WATER RETURN
FTR FINNED TUBE RADIATOR
GA GAUGE
GEV GRAVITY EXHAUST VENTILATOR
GPM GALLONS PER MINUTE
GIV GRAVITY INTAKE VENTILATOR
GTS GEOTHERMAL SUPPLY
GTR GEOTHERMAL RETURN
H HEIGHT
HWR HOT WATER RETURN
HWS HOT WATER SUPPLY
IDU INDOOR UNIT
GWB GYPSUM WALLBOARD
WPD WATER PRESSURE DROP
WSA WIRE SIZE AMPS
NEMA NATIONAL ELECTRICAL MANUFACTURER'S
ASSOCIATION
OPD OVERCURRENT PROTECTION DEVICE
P PUMP
PSI, PSIG POUNDS PER SQUARE INCH, PSI GAUGE
UL UNDERWRITERS LABORATORIES
GENERAL MECHANICAL NOTES
1. INSTALLATION OF HVAC WORK SHALL BE COORDINATED
WITH OTHER TRADES BEFORE ANY INSTALLATION IS
MADE. EQUIPMENT, PIPING OR DUCTWORK INTERFERING
WITH OTHER TRADES SHALL BE RELOCATED AS
REQUIRED AT NO ADDITIONAL COST.
2. COORDINATE MECHANICAL AND ELECTRICAL SUCH THAT
MECHANICAL PIPING, DUCTWORK AND EQUIPMENT IS NOT
LOCATED OVER OR ABOVE ANY ELECTRICAL,
COMMUNICATIONS, OR DATA EQUIPMENT.
3. AT START OF CONSTRUCTION, PREPARE TYPED LISTS OF
EQUIPMENT BEING SUPPLIED REQUIRING ELECTRICAL WORK,
AND SEND LISTS TO THE ELECTRICAL CONTRACTOR FOR
REVIEW AND COORDINATION.
4. WRITTEN DIMENSIONS ON DRAWINGS SHALL HAVE
PRECEDENCE OVER SCALED DIMENSIONS.
5. EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH
MANUFACTURER'S APPROVED PUBLISHED LITERATURE.
6. INSTALLATION OF EQUIPMENT SHALL PERMIT ACCESSIBILITY
FOR SERVICE AND/OR REPLACEMENT.
7. CEILING-MOUNTED EQUIPMENT SHALL BE INSTALLED IN SUCH
A MANNER THAT LIGHTS, PIPING, DUCTWORK, ETC., DO NOT
BLOCK ACCESS TO EQUIPMENT AND RELATED ACCESSORIES.
8. COORDINATE ALL WALL, FLOOR AND ROOF PENETRATIONS
WITH THE CONSTRUCTION PROFESSIONAL.
9. CAULK WITH SILICONE ALL GAPS BETWEEN WALL, CEILING
AND FLOOR OPENINGS AND HVAC EQUIPMENT PENETRATIONS.
PATCH LARGE GAPS BEFORE CAULKING IS APPLIED.
10. SUPPLEMENTAL STEEL MEMBERS REQUIRED TO SUPPORT
HVAC EQUIPMENT FROM MAIN STRUCTURE SHALL BE
PROVIDED.
11. DUCTWORK AIR DISTRIBUTION SYSTEMS SHALL BE INSTALLED
IN ACCORDANCE WITH SMACNA STANDARDS AND THE
PRESSURE CLASSIFICATION OF EACH INDIVIDUAL DUCTWORK
SYSTEM, NOT LESS THAN 2 IN.W.G., SEAL CLASS A (LEAKAGE
CLASS 6, OR 4% OF THE TOTAL AIR FLOW THROUGH THE
DUCT). DUCT SIZES SHOWN ON DRAWINGS ARE INSIDE CLEAR
DIMENSIONS.
12. VOLUME DAMPERS SHALL BE PROVIDED AT EACH NEW MAIN
BRANCH TAKE-OFF AND IN SUCH OTHER LOCATIONS WHERE
REQUIRED TO PROPERLY BALANCE THE SYSTEM.
13. INSTRUMENT TEST HOLES SHALL BE PROVIDED IN AIR
DISTRIBUTION SYSTEMS WHEREVER VOLUME DAMPERS ARE
SHOWN.
14. SQUARE ELBOWS SHALL ONLY BE USED WHERE SPACE
LIMITATIONS PREVENT USE OF 1.5 RADIUS ELBOW AND ONLY
UPON APPROVAL OF DESIGN PROFESSIONAL. PROVIDE TURNING
VANES IN ALL 45° AND 90° SQUARE ELBOWS. TURNING VANES
SHALL BE SINGLE THICKNESS TYPE WITHOUT RAILING EDGE. IF
TURNINGVANES LONGER THAN 36 INCHES ARE REQUIRED, THEY
SHALL BE DOUBLE THICKNESS TYPE FOR STRENGTH.
15. PROVIDE SHEETMETAL TRANSITIONS AT AIR HANDLING UNITS, HEAT
PUMP UNITS, FANS, AND OTHER SIMILAR HVAC EQUIPMENT.
FLEXIBLE DUCT CONNECTORS OR SOUND ATTENUATION
DEVICES SHALL BE USED ON CONNECTION TO AIR HANDLING
EQUIPMENT TO REDUCE NOISE TRANSFER INTO OCCUPIED
SPACES.
16.
BLANK OFF INACTIVE PORTIONS OF LOUVERS UTILIZED
FOR INTAKE OR DISCHARGE FOR HVAC EQUIPMENT. ENTIRE
LOUVERS NOT UTILIZED SHALL BE BLANKED OFF BY THE
LOUVER MANUFACTURER. REFER TO ARCHITECTURAL
DRAWINGS FOR LOUVER LOCATIONS AND HVAC DRAWINGS
FOR HVAC EQUIPMENT CONNECTIONS.
17. EXACT LOCATIONS OF THERMOSTATS, CO2 SENSORS, AND
EMCS SENSORS SHALL BE COORDINATED WITH FINAL
LOCATIONS OF WALL-MOUNTED ARCHITECTURAL AND
ELECTRICAL EQUIPMENT. MOUNT THERMOSTATS AND HUMIDISTAT
SENSORS MINIMUM 48" AFF.
18. SUPPLY AND OUTDOOR AIR DUCTWORK SHALL
BE INSULATED TO MEET OR EXCEED ASHRAE 90.1-2010.
INTERIOR SUPPLY, RETURN, AND OUTDOOR AIR DUCTWORK
SHALL BE INSULATED FOR A MINIMUM VALUE OF R-6.
19.
COORDINATE CONDENSATE DRAIN PIPING WITH EXISTING
CONDITIONS. PROVIDE CONDENSATE PUMPS
AS REQUIRED WHERE SUFFICIENT SLOPE IS NOT
AVAILABLE FOR STANDARD GRAVITY DRAIN, WITH
OVERRIDE SWITCH TO POWER DOWN THE ASSOCIATED AIR
HANDLING EQUIPMENT IN CASE OF CONDENSATE PUMP
FAILURE. CONDENSATE DRAIN PIPING SHALL BE SLOPED
FOR GRAVITY AT A MINIMUM OF 2% SLOPE.
20. PROVIDE SUPPORTS FOR PIPING AND DUCTWORK IN
ACCORDANCE WITH SPECIFICATIONS. STRAP SUPPORTS
INSTALLED IN DIRECT CONTACT WITH PIPING OR DUCTWORK
SHALL HAVE INSULATION APPLIED AROUND STRAP FOR
CONTINUOUS INSULATION VALUE FOR THE PIPE OR DUCT.
FOR SUPPORT OF PRE-INSULATED PIPING OR DUCTWORK, USE
HIGH-DENSITY INSULATION ON BOTTOM OF PIPE OR DUCT TO
PREVENT CRUSHING OR PROVIDE SADDLES OR SHIELDS TO
PREVENT CRUSHING OF INSULATION. ADHERE THE SADDLE
TO THE INSULATION POSITION SUPPORT LOCATED IN
CENTER OF THE SADDLE WHILE SYSTEM IS AT NOMINAL
OPERATING TEMPERATURE. PIPE HANGERS AND SUPPORTS
SHALL BE IN ACCORDANCE WITH MSS SP-58.
21. ALL DIFFERENTIAL PRESSURE SENSOR LOCATIONS TO HAVE
PORTS FOR TEST AND BALANCE VERIFICATION.
22. EXISTING UTILITIES MAY NEED TO BE SHIFTED TO ACCOMMODATE NEW
WORK. IT IS THE CONTRACTOR'S RESPONSIBILITY TO MOVE ANY
UTILITY, DUCT, PIPING, OR FIXTURES NEEDED TO INSTALL NEW WORK.
SEE PHOTOS ON M-901 SHEET FOR EXISTING CONDITIONS.
23. NCTC CAMPUS ONLY USES JOHNSON CONTROLS. LOCAL CONTACT IS
BRIAN BONNEY (OFFICE: 410-527-2746 AND EMAIL
BRIAN.D.BONNEY@JCI.COM)
1 2 3 4 5
A
B
C
D
D W
N
B
Y
C K
D
B
Y
S U
B M
I T
T E
D
B
Y
D A
T E
SHEET
IDENTIFICATION
D E
S I G
N E
D
B
Y
F I L
E
N
A M
E
P a r k w a y
L a n e
S u i t e
N o r c r o s s
G
A
P h o n e
F a x
P L
T
E
S I Z
E
A R
O
L I C
I T
A T
I O
N
N
O
C O
N T
R A
F I L
E
N
O
A P
P R
D
A T
E D
E S
C R
I P
T I O
N M
A R
K
U S
F
I S
H
A
L
D L
I F
E
N C
M
P U
S
D
I S
T R
I C
T
S H
E P
H E
R D
S T
O W
N
W
V
D E
H U
M I D
I F
I C
A T
I O
N
S
Y S
T E
M
F
O R
L O
D G
E
D
I N
G
D
A R
L I N
G
H
S H
E P
H E
R D
S T
O W
N
W
E S
T
V
I R
G I N
I A
J O
B
N
O
100% DESIGN SUBMISSION
D W
E
D W
E M
I Z
E S
A
G E
N E
R A
L
N
O T
D
A B
B R
E V
I A
T I O
N
M-001-H2
A
AIRFLOW
DIFFUSER TYPE
A
24x24 FACE SIZE
SUPPLY/RETURN/EXHAUST TAGS
TRANSFER GRILLE TAGS
M501
PLAN NORTH
DRAWING/DETAIL REFERENCE KEY
REFER TO
DETAIL NUMBER
SHEET NUMBER OF DETAIL
RE:2/M501
NORTH ARROW
A
J
SD
SP
F
T
TH
A
C
DUCT SMOKE DETECTOR
CARBON DIOXIDE SENSOR
DRAWING NOTE REFERENCE
OVAL OR FLAT OVAL
CONTROL WIRING
STATIC PRESSURE SENSOR
ROUND
THERMOSTAT
FIRESTAT
TEMPERATURE SENSOR
HUMIDITY SENSOR
MISCELLANEOUS LEGEND
H
T
120 VOLT STAND BY POWER JUNCTION
BOX PROVIDED BY THE ELECTRICAL
CONTRACTOR JUNCTION BOX IS
DEDICATED FOR USE BY THE CONTROLS
CONTRACTOR.
VARIABLE FREQUENCY DRIVEVFD
THERMOSTAT/HUMIDISTAT
PIPING LEGEND
EXPANSION JOINT
FLEXIBLE CONNECTION
CLEANOUT
WATER METER
FLOOR CLEANOUT
THERMOMETER
PRESSURE REDUCING VALVE
MANUAL AIR VENT
WITH BALL VALVE
PRESSURE/TEMPERATURE TAP
PRESSURE SWITCH
PLUG VALVE
FLOW SWITCH
T&P RELIEF VALVE
AUTOMATIC AIR VENT
PRESSURE GAUGE WITH GAUGE COCK
PS
FS
BUTTERFLY VALVE
STRAINER WITH BLOWDOWN VALVE,
FLOW MEASURING/BALANCING/
SHUT-OFF VALVE
GATE VALVE
CHECK VALVE
BALL VALVE
CAP AND CHAIN
3-WAY CONTROL VALVE
2-WAY CONTROL VALVE
CWR
CONDENSER WATER RETURN
CONCENTRIC REDUCER
DIRECTION OF FLOW
DIRECTION OF SLOPE DOWN
ECCENTRIC REDUCER
PIPE FLANGE
PIPE CAP
PIPE GUIDE
PIPE ANCHOR
X
UNION
TEE OUTLET UP
CONDENSATE DRAIN
BRANCH BOTTOM CONNECTION
PUMPED CONDENSATE
BRANCH TOP CONNECTION
ELBOW UP
ELBOW DOWN
RISE OR DROP
TEE OUTLET DOWN
PC
CD
REFRIGERANT SUCTION
RS
CWS
CONDENSER WATER SUPPLY
HWS
HEATING WATER SUPPLY
HWR
HOT WATER RETURN
M
SUPPLY OR OUTSIDE AIR DUCT UP
AD
FD(3) - FIRE DAMPER, 3 HOUR RATING
FD - FIRE DAMPER, 1 HOUR RATING
FIRE DAMPER TYPE:
H
UP
DN
DUCT MOUNTED HUMIDIFIER
RISE IN DUCT
DROP IN DUCT
RETURN OR EXHAUST AIR DUCT DOWN
RETURN OR EXHAUST AIR DUCT UP
SUPPLY OR OUTSIDE AIR DUCT DOWN
30x14
SQUARE TO ROUND DUCT BRANCH TAKE-OFF
FLARED SPIN-IN WITH DAMPER AND
FLEX DUCT (DIFFUSER CONNECTION)
ROUND DUCT BRANCH TAKE-OFF FROM
RECTANGULAR MAIN WITH CONICAL TAP
FLEXIBLE DUCT CONNECTION
WITH 45 DEGREE BRANCH INLET
FLOW ARROW
DUCT SIZE TRANSITION
RECTANGULAR DUCT BRANCH TAKE-OFF
WITH 45 DEGREE BRANCH INLET
DASHED LINES INDICATE 2" ACOUSTICAL LINER
90 DEGREE DUCT ELBOW WITH TURNING VANES
FLEXIBLE DUCT
24"
DUCTWORK LEGEND
RETURN AIR DEVICE
ROUND DUCT. DIAMETER INDICATED IN INCHES.
IN-LINE 90 DEGREE RISE/DROP IN
SUPPLY DUCT (RIGHT SIDE IS HIGHER)
IN-LINE 90 DEGREE RISE/DROP IN
RETURN DUCT (RIGHT SIDE IS HIGHER)
FD
SD
AD - AUTOMATIC DAMPER
DAMPER TYPE:
MD - MOTORIZED DAMPER
VD
SMOKE DAMPER
VOLUME/BALANCING DAMPER
(LABEL MAY BE OMITTED)
BD
BACKDRAFT DAMPER
(COUNTER-BALANCED UNLESS
OTHERWISE NOTED)
RADIUS DUCT ELBOW - ROUND OR
RECTANGULAR (MIN. 1.5 RADIUS UNLESS
OTHERWISE NOTED)
RECTANGULAR DUCT, SIZE INDICATED IN
INCHES, FIRST NUMBER IS SIDE SHOWN
SUPPLY AIR DIFFUSER -
FLOW ARROWS INDICATE AIR
PATTERN.
NO FLOW ARROWS SHOWN INDICATES
4-WAY PATTERN.
FSD
COMBINATION
FIRE/SMOKE DAMPER
EXHAUST AIR DEVICE
M
VFD
M
T
DP
FS
RH
SD
CT
M
FS
C
PS
SP
CONTROLS LEGEND
FAN
PUMP
ENERGY WHEEL
COIL - COOLING
MOTORIZED DAMPER
FILTERS
MOTORIZED 2-WAY CONTROL VALVE
VARIABLE FREQUENCY DRIVE
MOTOR
CURRENT TRANSDUCER
TEMPERATURE SENSOR
HUMIDITY SENSOR
CARBON DIOXIDE SENSOR
DIFFERENTIAL PRESSURE SENSOR
FLOW SENSOR/ STATION
PRESSURE SWITCH
STATIC PRESSURE SENSOR
DUCT SMOKE DETECTOR
FREEZESTAT
TEMPERATURE SENSOR - PIPE
SIGNAL TO DDC SYSTEM
SIGNAL FROM DDC SYSTEM
DDC
DDC
COIL - HEATING
39.40 N
LONGITUDE:
ELEVATION:
LATITUDE:
SUMMER DESIGN WET BULB (1%):
SUMMER DESIGN DRY BULB (1%):
WINTER DESIGN DRY BULB (99%):
STANDARD DESIGN CONDITIONS:
15.8°F
75.4°F
90.4°F
77.98 W
535 FT.
HVAC DESIGN CRITERIA
LOCATION: EASTERN WV REGNL SHE, WV,
USA (WMO#724177)
*STANDARD & CRITICAL DESIGN CONDITIONS FROM ASHRAE
MEAN COINCIDENT DRY BULB (1%):
HUMIDITY RATIO (1%):
DEHUMIDIFICATION DESIGN CONDITIONS:
122.5
80.0°F
DEWPOINT (99%): 72.4°F
CONNECT TO EXISTING
FLOOR DRAIN
1 2 3 4 5
A
B
C
D
D W
N
B
Y
C K
D
B
Y
S U
B M
I T
T E
D
B
Y
D A
T E
SHEET
IDENTIFICATION
D E
S I G
N E
D
B
Y
F I L
E
N
A M
E
P a r k w a y
L a n e
S u i t e
N o r c r o s s
G
A
P h o n e
F a x
P L
T
E
S I Z
E
A R
O
L I C
I T
A T
I O
N
N
O
C O
N T
R A
F I L
E
N
O
A P
P R
D
A T
E D
E S
C R
I P
T I O
N M
A R
K
U S
F
I S
H
A
L
D L
I F
E
N C
M
P U
S
D
I S
T R
I C
T
S H
E P
H E
R D
S T
O W
N
W
V
D E
H U
M I D
I F
I C
A T
I O
N
S
Y S
T E
M
F
O R
L O
D G
E
D
I N
G
D
A R
L I N
G
H
S H
E P
H E
R D
S T
O W
N
W
E S
T
V
I R
G I N
I A
J O
B
N
O
100% DESIGN SUBMISSION
D W
E
D W
E M
I Z
E S
A
M E
C H
A N
I C
A L
L E
G E
N D
M-002-H2
G24H
MECHANICAL
ROOM
LARGE
G20H
MECHANICAL
ROOM
SMALL
G21H
GENERAL
STORAGE
H2-R-1
1 2 3 4 5
A
B
C
D
D W
N
B
Y
C K
D
B
Y
S U
B M
I T
T E
D
B
Y
D A
T E
SHEET
IDENTIFICATION
D E
S I G
N E
D
B
Y
F I L
E
N
A M
E
P a r k w a y
L a n e
S u i t e
N o r c r o s s
G
A
P h o n e
F a x
P L
T
E
S I Z
E
A R
O
L I C
I T
A T
I O
N
N
O
C O
N T
R A
F I L
E
N
O
A P
P R
D
A T
E D
E S
C R
I P
T I O
N M
A R
K
U S
F
I S
H
A
L
D L
I F
E
N C
M
P U
S
D
I S
T R
I C
T
S H
E P
H E
R D
S T
O W
N
W
V
D E
H U
M I D
I F
I C
A T
I O
N
S
Y S
T E
M
F
O R
L O
D G
E
D
I N
G
D
A R
L I N
G
H
S H
E P
H E
R D
S T
O W
N
W
E S
T
V
I R
G I N
I A
J O
B
N
O
100% DESIGN SUBMISSION
D W
E
D W
E M
I Z
E S
A
SCALE: 1/8" = 1'-0"
8 0 8 16
SCALE: 1/8" = 1'-0"
H2 (DING DARLING) - GROUND FLOOR
GENERAL NOTES:
1. DRAWINGS ARE BASED OFF OF AS-BUILT DRAWINGS.
VERIFY FIELD CONDITIONS PRIOR TO START OF
CONSTRUCTION.
2. THE SCOPE OF THIS PROJECT IS LIMITED TO MECHANICAL
ROOMS EXCEPT FOR CONDUIT AND WIRING REQUIRED
THAT WILL BE RUN IN CORRIDORS. THE BUILDING WILL BE
OCCUPIED DURING CONSTRUCTION AND ALL SYSTEMS
MUST REMAIN OPERATIONAL.
3. CEILINGS IN MECHANICAL SPACES ARE OPEN TO
STRUCTURE BUT AVAILABLE SPACE IS LIMITED DUE TO
CONGESTION OF EXISTING SYSTEMS. CORRIDORS AND
OCCUPIED SPACES HAVE HARD CEILINGS.
4. CONTRACTOR RESPONSIBLE FOR PATCHING AND
PAINTING TO MATCH EXISTING CONDITIONS IF DAMAGED
DURING CONSTRUCTION.
M E
C H
A N
I C
A L
G
R O
U N
D
F L O
A
N
KEY NOTES:
EXISTING EXHAUST LOUVER
EXISTING OUTSIDE AIR LOUVER
M-101-H2
Ø
D
H
H
AC-H2-1
DH-H2-2
10"Ø SA
10"Ø RA
x
G24H
MECHANICAL
ROOM
LARGE
G21H
GENERAL
STORAGE
G20H
MECHANICAL
ROOM
SMALL
x
EXISTING
PUMPS
E
X
I S
T
I N
G
C
H
I L
L
E
R
E
F
H x
14"x12"
Ø
AC-H2-2
FD
FD
1 2 3 4 5
A
B
C
D
D W
N
B
Y
C K
D
B
Y
S U
B M
I T
T E
D
B
Y
D A
T E
SHEET
IDENTIFICATION
D E
S I G
N E
D
B
Y
F I L
E
N
A M
E
P a r k w a y
L a n e
S u i t e
N o r c r o s s
G
A
P h o n e
F a x
P L
T
E
S I Z
E
A R
O
L I C
I T
A T
I O
N
N
O
C O
N T
R A
F I L
E
N
O
A P
P R
D
A T
E D
E S
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.