IFB 2026-056 Union County School Administration Roof Replacement Project

Closed State & local contract opportunity Posted

Solicitation number
377-2026-056
State
North Carolina
Responses due

Opportunity facts

Jurisdiction

Opportunity details come from evp.nc.gov. Updated .

About this opportunity

Union County, North Carolina Department of Public Works is requesting bids on roof replacement at the Union County School Administration building located at 400 North Church Street in Monroe under IFB 2026-056, with sealed bids due July 9, 2026 at 2:00 p.m. local time and a non-mandatory pre-bid conference and site visit scheduled for June 23, 2026 at 10:00 a.m.

The scope includes removal of the existing roof system down to the structural deck and installation of a new roof system with sheet metal flashing and accessories providing a complete, watertight, 20-year warrantable assembly. Work also encompasses HVAC modifications: raising two rooftop units at roof section C to provide minimum 8-inch flashing height, rerouting and raising gas lines to accommodate roof installation, and providing new insulated ductwork and supports. Two alternates are offered — Alternate No. 1 for new elevation wall sealant joints around the building perimeter, and Alternate No. 2 for approximately 40 linear feet of new fall protection handrails on roof area C along the gutter edge at HVAC units.

The architect is Gensler Architecture, Design & Planning, P.C., and the engineer is REI Engineers, Inc., with construction documents dated May 29, 2026. Sealed bids must be submitted at the Union County Procurement and Contract Management office at 610 Patton Avenue, Monroe, North Carolina 28110. Inquiries should be directed to Corey Brooks, Director of Procurement and Contract Management, at (704) 283-3683 or corey.brooks@unioncountync.gov.

Opportunity text

IFB 2026-056 Union County School Administration Roof Replacement Project Scope of Work: Remove existing roof system down to the existing structural deck and provide new roof system along with sheet metal flashing and accessories to provide a complete, watertight, 20-year warrantable roof assembly. HVAC Modification: Raise 2 HVAC units at roof C providing minimum 8" flashing height, reroute/raise gas lines to provide adequate space for roof installation, and provide new insulated ductwork and supports from units to wall penetration. Alternate NO. 1: Provide new elevation wall sealant joints around perimeter of the building. Alternate NO. 2: Provide approximately 40 LF of new fall protection handrails on roof area C along gutter edge at HVAC units.

Files

File Type Posted
Addenda No.1.pdf PDF
IFB 2026-056 Advertisement Pages.pdf PDF
Addenda No.2.pdf PDF
Addenda No.3.pdf PDF

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Similar opportunities
  • Ask GovTribe AI about this opportunity