Notice of Intent to Noncompetitively CHIPS XAFS and Diffraction, Silicon Drift Detector

Award Notice Posted

Solicitation number
1333ND24PNB030428
Agency
Awarded
to Dectris USA Inc.
Set-aside
No set-aside

Opportunity facts

Contract number
1333ND24PNB030428 Federal contract award
Place of performance
Upton, New York 11973, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The National Institute of Standards and Technology (NIST), an agency under the Department of Commerce, awarded a sole source contract (1333ND24PNB030428) to DECTRIS USA INC on September 30, 2024, valued at $798,300 for the procurement of two commercial X-ray detectors for the Beamline for Materials Measurement facility at Brookhaven National Laboratory. The acquisition includes a strip detector for high-resolution X-ray diffraction and a large-area, photo-counting X-ray detector designed to support semiconductor research under the CHIPS Research and Development Program in coordination with IBM researchers. Both detectors must meet stringent technical specifications including photon-counting pixel detector capabilities with six decades of dynamic range and count rates exceeding 10⁵ photons per second per pixel for the strip detector and 10⁶ photons per second per pixel for the large-area detector. NIST's extensive market research conducted from August 2023 through May 2024, which included a sources sought notice and requests for information, determined that Dectris AG was the sole commercial source capable of meeting all required technical specifications.

Notice text

Awarded on a sole source basis in accordance with the attached Justirifaction for Other Than Full an Open Competition. 

Awarded contract 1333ND24PNB030428 to DECTRIS USA INC for 798300.00 on 2024-09-30.

Files

File Type Posted
NB305000-24-01014 JOFOC (002) (002)_Redacted.pdf PDF

Notice history

Notice Type Posted
CHIPS XAFS and Diffraction, Silicon Drift Detector Latest Award Notice
This notice Award Notice
Notice of Intent to Noncompetitively CHIPS XAFS and Diffraction, Silicon Drift Detector Latest special notice Special Notice
CHIPS XAFS and Diffraction, Silicon Drift Detector Original Pre-Solicitation