6515--SIROLaser Blue USA Laser
Closed Solicitation Posted
- Solicitation number
- 36C24524Q0915
- Agency
-
Veterans Integrated Service Network 5
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 339114 Dental Equipment and Supplies Manufacturing
- Place of performance
- Washington Dc Va Medical Center 50 Irving Street Nw, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs, Veterans Health Administration, Veterans Integrated Service Network 5 is seeking to procure a FDA approved diode laser unit with blue wavelength for use in various dental procedures at the Washington DC VA Medical Center. The scope of work includes providing all necessary parts, materials, labor, software/licenses, resources, and training to fully implement the equipment. Key requirements include multiple wavelengths, operation modes, and detailed technical specifications for the SIROLaser Blue laser unit and associated accessories. Responses are due by September 20, 2024 at 5:00 PM Eastern Time, and the contract will be awarded to a manufacturer-approved distributor or reseller that can document their ability to provide the required items through the manufacturer's approved distribution channels.
This is an unrestricted brand name only requirement, as no small business distributors were found that are authorized to sell this specialized equipment. The estimated value of this procurement is undisclosed. The solicitation is for two SIROLaser Blue laser units and associated accessories, to be delivered within 60 days of award. The place of performance is the Washington DC Veterans Affairs Medical Center.
Notice text
SIROLaser Blue Dental Laser
Brand name only
Description
The Washington DC Veterans Affairs Medical Center has a requirement for a FDA approved diode laser unit with blue wavelength that offers a wide range of applications in periodontics, endodontics, and dental surgery and desensitization.
Scope of Work
The procurement shall include all parts, materials, labor, software/licenses, resources, and training required to implement and utilize the equipment/system to their fullest capacity. All items must be covered by manufacturer s warranty and procured through a manufacturer-approved distribution channel. Distributers and resellers must be able to document ability to provide items through manufacturer-approved distribution channels upon request.
Specifications
4.1 Equipment
Line Item Description
Quantity
SIROLaser Blue USA / 6654227
2
Easy Tip 320 Pack of 25 / 6498062
2
Easy Tip 200 Pack of 25 / 6498484
2
Easy Tip 200 Endo / 6535905
2
8mm Therapy light guide/ 6541465
2
4mm Therapy light guide/ 6541499
2
Optic protective cap for handpiece/ 6579580
2
Fiber cutter/ 6091669
2
Bending tool/ 6217348
2
Laser Safety googles for users/ 6617703
2
Laser Safety goggles for patients / 6541523
2
4.2 Required Features
A Blue laser equipped with a high-tech laser module, which provides three different forms of laser in a single device
Has invisible infrared
Has a blue wavelength is 445 nm for soft tissue surgery
Has a infrared wavelength is 970 nm for perio and hygiene procedures
Has a red wavelength is 660nm for photobiomodulation
Has several different Laser operation modes. The continuous wave mode implies a continuous, uninterrupted laser beam. The chopper mode also called pulse mode the laser beam is interrupted at regular intervals.
Has manual setting changes and custom presets can be set
Tabletop laser device
Device has a touch screen, laser stop key, carry handle, finger switch with exchangeable key pad, metal handpiece sleeve, handpiece holder and cable for optical fiber and wires
The beam guide is flexible quartz glass fiber
Has a fill color, graphical LCD touch screen
Has internal air cooling by output
Dimensions are 182x 197x 189mm
The weight is 1300g including the handpiece and rechargeable battery
The optical fiber thickness is 200 and 320um for the fiber tip and 4 and 8 mm for the glass rods
Power input is 15V DC 6.66 A max. 100 VA MPU101-106
Input voltage is 100-240 VAC
Input current is 1.25-0.5A
Input frequencies are 47-63 Hz
The optical fiber material has an attenuation of 1 db/km @ 970 nm
Tensile strength is 70 kpsi
Wireless foot control frequency is 2.4 GHz-2.4835 GHz, has transmitting power of
Files
| File | Type | Posted |
|---|---|---|
| 36C24524Q0915_1.docx | DOCX document | |
| Attachment 1 Single Source Justification MPT to SAT SIROLaser Blue 2_Redacted.pdf | ||
| 36C24524Q0915 SIROLaser Blue.pdf |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Q999--MO | Surgical Laser Service | 663 5 year IDIQ : 2/11/2027-2/10/2032 | Veterans Integrated Service Network 20 | No set-aside | |
| 6540--Carl Zeiss Visulas Combi YAG Green (VA-26-00065932) | Veterans Integrated Service Network 12 | No set-aside | |
| 6520--NX EQ Dental Handpieces | VA Strategic Acquisition Center Frederick | No set-aside | |
| J065--alcon constellation LXT phacoemulsification units and embedded lasers PMI services | 2026-2031 | Veterans Integrated Service Network 22 | No set-aside | |
| Z1DZ--Replace Dental Vacuum Piping | Veterans Integrated Service Network 21 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity