093000 - 1 TILING

SECTION 093000 – TILING

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes:

1. Ceramic wall tile.

2. Ceramic floor tile.

3. Metal edge strips.

1.2 SUBMITTALS

A. Product Data: For each type of product indicated.

B. Samples:

1. Each type and composition of tile and for each color and finish required.

PART 2 - PRODUCTS

2.1 TILE PRODUCTS

A. ANSI Ceramic Tile Standard: Provide Standard grade tile that complies with ANSI A137.1 for types, compositions, and other characteristics indicated.

B. Manufacturers and Products:

1. Manufacturers:

a. Daltile Tile (Basis-of Design).

b. Emser Tile.

c. American Olean.

d. Crossvile.

e. Or Equal.

2. See Architectural Finishes Schedule

3. Composition: Porcelain.

4. Module Size: As indicated in the Architectural Finishes Schedule

5. Thickness: Manufacturers standard

6. Finish: Manufacturers standard glaze.

7. Tile Color and Pattern: As indicated in the Architectural Finishes Schedule and in the drawings.

8. Grout Color: As indicated in the Architectural Finishes Schedule.

9. Trim Units: Coordinated with sizes and coursing of adjoining flat tile where applicable. Provide shapes as follows, selected from manufacturer's standard shapes:

a. Base Cove: Cove, module size 6”x12”.

TILING 093000 - 2

2.2 ACCESSORY MATERIALS

A. Thresholds: Fabricate to provide transition between adjacent floor finishes.

1. Metal thresholds: Schluter-RENO-U clear anodized aluminum floor transition.

2. Marble or stone thresholds: ASTM C 503 with a minimum abrasion resistance of

10 per ASTM C 1353 or ASTM C 241 and with honed finish. Bevel edges at 1:2 slope, limit height of bevel to 1/2 inch (12.7 mm) or less, and finish bevel to match face of threshold

a. Description: Uniform, fine- to medium-grained veining. Coordinate color with adjacent materials.

B. Waterproofing and Crack-Suppression Membranes for Thin-Set Tile Installations:

Manufacturer's standard product that complies with ANSI A118.10.

1. Latex-Portland Cement Product: Flexible mortar with acrylic-latex additive.

a. Products:

1) Boiardi Products Corporation; Elastiment 323.

2) MAPEI Corporation; PRP 315.

3) TEC Specialty Products Inc.; TA-324, Triple Flex.

4) Or Equal.

2. Schluter®-KERDI

a. Description: 0.008 inch (0.2 mm) thick, orange polyethylene membrane, with polypropylene fleece laminated on both sides, which meets or exceeds the requirements of the “American national standard specifications for load bearing, bonded, waterproof membranes for thin-set ceramic tile and dimension stone installation A118.10,” and is listed by cUPC®, and is evaluated by ICC-ES (see Report No. ESR-2467).

2.3 SETTING MATERIALS

A. Manufacturers:

1. Custom Building Products (Basis of Design).

2. Bostik.

3. DAP, Inc.

4. MAPEI Corporation.

5. Or Equal.

B. Portland Cement Mortar (Thickset) Installation Materials: ANSI A108.1A.

C. Dry-Set Portland Cement Mortar (Thin Set): ANSI A118.1.

1. For wall applications, provide non-sagging mortar.

D. Latex-Portland Cement Mortar (Thin Set): ANSI A118.4.

093000 - 3 TILING

1. Prepackaged dry-mortar mix containing dry additive to which only water must be added.

2. Prepackaged dry-mortar mix combined with liquid-latex additive.

3. For wall applications, provide non-sagging mortar.

E. Medium-Bed, Latex-Portland Cement Mortar: Comply with requirements in ANSI A118.4. Provide product that is approved by manufacturer for application thickness of 5/8 inch.

1. Basis-of Design: Megalite® Crack Prevention Mortar as manufactured by Custom Building Products.

2.4 GROUT MATERIALS

A. Standard Unsanded Cement Grout: ANSI A118.6.

1. Polymer Type: Dry, redispersible form, prepackaged with other dry ingredients.

B. Lightweight polymer-modified, cement based Tile Grout: ANSI A108.10 and A118.7, color from manufacturer’s standard colors.

1. Basis-of Design: Prism® Surecolor® Grout as manufactured by Custom Building Products.

2.5 MISCELLANEOUS MATERIALS

A. Metal Edge Strips: All outside corners:

1. Schluter-RONDEC clear anodized aluminum corner bead.

B. Shower Accessories: soap niche

1. Schluter®-KERDI-BOARD-SN: Prefabricated waterproof niche, constructed of rigid extruded polystyrene foam building element panel, with reinforcement material and polypropylene fleece webbing laminated on both sides for thin-set ceramic tile and dimension stone Installations.

2. Nominal Niche Size:

12 inches x 12 inches x 3 1/2 inches (305 mm x 305 mm x 89 mm)

C. Elastomeric Sealants: Elastomeric sealants of base polymer and characteristics indicated that comply with applicable requirements in Division 7 Section "Joint Sealants."

1. Use sealants that have a VOC content of 250 g/L or less when calculated according to 40 CFR 59, Subpart D (EPA Method 24).

2. One-Part, Mildew-Resistant Silicone: ASTM C 920; Type S; Grade NS;

Class 25; Uses NT, G, A, and, as applicable to nonporous joint substrates indicated, O; formulated with fungicide, intended for in-service exposures of high humidity and extreme temperatures.

a. Products:

1) Dow Corning Corporation; Dow Corning 786.

TILING 093000 - 4

2) GE Silicones; Sanitary 1700.

3) Tremco, Inc.; Tremsil 600 White.

4) Or Equal.

3. Multipart, Pourable Urethane Sealant for Use T: ASTM C 920; Type M; Grade P;

Class 25; Uses T, M, A, and, as applicable to joint substrates indicated, O.

a. Products:

1) Bostik; Chem-Calk 550.

2) Mameco International, Inc.; Vulkem 245.

3) Tremco, Inc.; THC-900.

4) Or Equal.

D. Grout Sealer: Manufacturer's standard silicone product for sealing grout joints that does not change color or appearance of grout.

PART 3 - EXECUTION

3.1 EXAMINATION

A. Examine substrates, areas, and conditions where tile will be installed, with Installer present, for compliance with requirements for installation tolerances and other conditions affecting performance of installed tile.

1. Verify that substrates for setting tile are firm, dry, clean, free of coatings that are incompatible with tile-setting materials including curing compounds and other substances that contain soap, wax, oil, or silicone; and comply with flatness tolerances required by ANSI A108.01 for installations indicated.

3.2 PREPARATION

A. Remove protrusions, bumps, and ridges by sanding or grinding.

B. Fill cracks, holes, and depressions in concrete substrates for tile floors installed with trowelable leveling and patching compound specifically recommended by tile-setting material manufacturer.

C. Blending: For tile exhibiting color variations, use factory blended tile or blend tiles at Project site before installing.

D. Field-Applied Temporary Protective Coating: If indicated under tile type or needed to prevent grout from staining or adhering to exposed tile surfaces, precoat them with continuous film of temporary protective coating, taking care not to coat unexposed tile surfaces.

3.3 INSTALLATION

A. Comply with TCA's "Handbook for Ceramic Tile Installation" for TCA installation methods specified in tile installation schedules. Comply with parts of the ANSI A108 Series "Specifications for Installation of Ceramic Tile" that are referenced in TCA installation

093000 - 5 TILING

methods, specified in tile installation schedules, and apply to types of setting and grouting materials used.

B. Extend tile work into recesses and under or behind equipment and fixtures to form complete covering without interruptions unless otherwise indicated. Terminate work neatly at obstructions, edges, and corners without disrupting pattern or joint alignments.

C. Accurately form intersections and returns. Perform cutting and drilling of tile without marring visible surfaces. Carefully grind cut edges of tile abutting trim, finish, or built-in items for straight aligned joints. Fit tile closely to electrical outlets, piping, fixtures, and other penetrations so plates, collars, or covers overlap tile.

D. Jointing Pattern: Lay tile in pattern indicated on drawings. Lay out tile work and center tile fields in both directions in each space or on each wall area. Lay out tile work to minimize the use of pieces that are less than half of a tile. Provide uniform joint widths unless otherwise indicated.

E. Joint Widths: Unless otherwise indicated, install tile with the following joint widths:

1. Porcelain Floor Tile: 3/16 inch.

2. Porcelain Wall Tile: 3/16 inch.

3. Glazed Wall Tile: 1/16 inch.

4. Exterior Wall Tile: 1/4 inch.

F. Metal Edge Strips: Install where exposed edge of tile flooring meets carpet, wood, or other flooring that finishes flush with or below top of tile and no threshold is indicated.

G. Stone Thresholds: Install stone thresholds at locations indicated; set in same type of setting bed as abutting field tile, unless otherwise indicated.

1. Set thresholds in latex-Portland Cement mortar for locations where mortar bed would otherwise be exposed above adjacent nontile floor finish.

H. Grout Sealer: Apply grout sealer to cementitious grout joints in tile floors according to grout-sealer manufacturer's written instructions. As soon as grout sealer has penetrated grout joints, remove excess sealer and sealer from tile faces by wiping with soft cloth.

I. Install cementitious backer units and treat joints according to ANSI A108.11 and manufacturer's written instructions for type of application indicated.

J. Install waterproofing to comply with ANSI A108.13 and waterproofing manufacturer's written instructions to produce waterproof membrane of uniform thickness bonded securely to substrate.

1. Do not install tile over waterproofing until waterproofing has cured and been tested to determine that it is watertight.

K. For installations indicated below, follow procedures in ANSI A108 Series tile installation standards for providing 95 percent mortar coverage.

1. Tile floors in wet areas.

TILING 093000 - 6

2. Tile floors composed of tiles 8 by 8 inches (200 by 200 mm) or larger.

3. Tile floors composed of rib-backed tiles.

3.4 INTERIOR TILE INSTALLATION SCHEDULE

A. Interior Floor Installations, Concrete Subfloor:

1. Tile Installation F113: Thin-set mortar; TCA F113.

a. Thin-Set Mortar: Dry-set Portland Cement mortar.

b. Grout: Polymer-modified unsanded Water-cleanable epoxy grout.

B. Interior Wall Installations, Masonry or Concrete:

1. Tile Installation W202: Thin-set mortar; TCA W202.

a. Thin-Set Mortar: Dry-set Portland Cement mortar.

b. Grout: Polymer-modified unsanded grout.

C. Interior Wall Installations, Metal Studs or Furring:

1. Tile Installation W244: Thin-set mortar on cementitious backer units or fiber cement underlayment; TCA W244.

a. Thin-Set Mortar: Dry-set Portland Cement mortar.

b. Grout: Polymer-modified unsanded grout.

D. Shower Receptor and Wall Installations, Concrete or Masonry:

1. Tile Installation B421: Thin-set mortar on waterproof membrane; TCA B421.

a. Thin-Set Mortar: Latex-Portland Cement mortar.

b. Grout: Polymer-modified unsanded grout.

END OF SECTION 093000