W912HN-18-R-3003_VOL2_AMD2.pdf
PDF 649 KB Posted
- Attached to
- Training Support Facility
- Solicitation number
- W912HN18R3003
About this file
Drawings Voll 2 Amd 2
View the file
Other files
| File | Type | Posted |
|---|---|---|
| amd3.pdf | ||
| 18R3003vol1.PDF | ||
| 18R3003vol1.PDF | ||
| 18R3003vol3.PDF | ||
| W912HN-18-R-3003_VOL1_AMD2.pdf | ||
| 18R3003vol2.PDF | ||
| amd2.pdf | ||
| 18R3003vol1.PDF | ||
| 18R3003vol2.PDF | ||
| amd1.pdf | ||
| 18R3003vol3.PDF | ||
| W912HN-18-R-3003_VOL2_AMD1.pdf | ||
| W912HN-18-R-3003_VOL1_AMD1.pdf | ||
| W912HN-18-B-3003_VOL1.pdf | ||
| 18R3003vol3.PDF | ||
| 18R3003vol2.PDF | ||
| 18R3003vol1.PDF | ||
| W912HN-18-B-3003_VOL2.pdf |
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
8" DIA X 5'-0" HIGH CONC.
FILLED STEEL BOLLARD, TYP.
OVERHEAD DOOR
ASSEMBLY
EXTERIOR WALL
ASSEMBLY
2'
- 0
3'
- 4
2'
- 0
AT EXTERIOR (OUTSIDE) CORNER
AT OVERHEAD DOOR
2' - 0"12" DIA X 5'-0" HIGH CONC.
FILLED STEEL BOLLARD, TYP.
8" DIA X 5'-0" HIGH CONC.
FILLED STEEL BOLLARD, TYP.
EXTERIOR WALL ASSEMBLY
FIN FLOOR
0"
CONT. THROUGH WALL FLASHING
OVER PREFINISHED METAL DRIP EDGE
WITH
WEEPS AT 32 INCHES O.C.
MORTAR NET
GROUT SOLID TO UNDERSIDE OF FLASHING
POURED
CONCRETE
FLOOR
SLAB SEE
STRUCTURAL
OVERLAP CONTROL LAYER ONTO
RADON/VAPOR BARRIER MIN. 12"
RADON/VAPOR BARRIER WRAPPED UP AND
SEALED TO THE EXTERIOR FACE OF THE
POURED CONCRETE FOUNDATION
SET STUD TRACK ON TWO
ROWS OF CONTINUOUS
SEALANT
CAST IRON DOWNSPOUT BOOT,
CONNECT TO STORM SEWER BELOW
GRADE, SEE CIVIL, TYP.
AIR BARRIER COMPONENT- VAPOR
IMPERMEABLE FACTORY PREFINISHED
INSULATED METAL WALL PANEL (R 21
MINIMUM) SYSTEM.
PREFINISHED ALUMINUM DOWN
SPOUT BEYOND
NOM. 4 INCH SPLIT-FACED CMU
2 INCH CAVITY
CONTINOUS LIQUID APPLIED CONTROL
LAYER OVER 5/8" GLASS MAT
GYPSUM SHEATHING
2 1/2 INCH RIGID INSULATION BOARD R10
MINIMUM
PREFINISHED METAL FLASHING SET IN
FULL BED OF SEALANT
PANEL CLIP, REFER TO
MANUFACTURER'S DETAILS
CONTINUOUS PRECAST CONCRETE CAPSTONE
PREFINISHED METAL DRIP FLASHING AT
BOTTOM OF METAL PANELS, WITH
BACKER ROD AND SEALANT BETWEEN
DRIP FLASHING AND COUNTERFLASHING
NOTE: SEE A-800 SERIES PLATES
FOR AIR BARRIER GUIDANCE.
R 13 BATT INSULATION, BETWEEN
LIGHT GAUGE METAL STUDS @ 16"
O.C., MAX.
CONT. METAL GIRT BY PRE-ENGINEERED
METAL BUILDING MANUFACTURER
8" METAL STUDS, NOTCHED AROUND GIRTS
METAL TRIM W/ HEMMED EDGE, PAINT TO
MATCH CORRUGATED METAL
PAINTED, CORRUGATED METAL, VERTICAL
CORRUGATIONS
PREFINISHED METAL COUNTERFLASHING
INSTALLED BEHIND RIGID INSULATION AND
BENT OVER TOP
ADJUSTABLE MASONRY WALL TIES W/
INSULATION CRUSH-PROOF LEGS, TYP.
2'
0"
RUN CONTROL LAYER DOWN OVER TOP OF
STAINLESS STEEL TERMINATION BAR AT
TOP OF THROUGH WALL FLASHING
NOM. 4" CMU
CONTINUE CONTROL LAYER ONTO
AND DOWN THE FACE OF FOOTING
PREFORMED JOINT
EXTERIOR CONCRETE, SEE CIVIL DRAWINGS
BLOCKING PER MANUFACTURER'S
REQUIREMENTS
W1
D
W2
1 3/4"
1 3/4" 2 5/8"
4 3/8"
3/8" CMU WALL
SEALANT AND
BACKER ROD
SEALANT AND BACKER ROD
JOINT CLEAR OF MORTAR
NOTE: PROVIDE JOINT IN PRECAST CONCRETE
AND BEJ AT MASONRY VENEER AT ALL CMU
CONTROL JOINT LOCATIONS
NOTE: BREAK METAL CMU WALL
REINFORCING ON BOTH SIDES OFCONTROL
JOINT
SEAL ALL AROUND GAP
BETWEEN PIPE SLEEVE AND
MASONRY W/ ELASTOMERIC
SEALANT W/ CLOSED CELL
BACKER ROD
OVERLAP SELF ADHESIVE AIR
BARRIER MEMBRANE OVER FLUID
APPLIED AIR BARRIER AT WALL
FACE AND SEAL TO PIPE SLEEVE -
MIN 4" LAP
PIPE SLEEVE
ESCUTCHEON AT ALL
FINISHED SPACES AND
WHERE SPECIFIED
MINERAL WOOL IN ANNULAR SPACE
EQUIPMENT FACE
PLATE OR
ESCUTCHEON -
PROVIDE BACKER ROD
& SEALANT AT
PERIMETER EDGE
FLUID APPLIED AIR
BARRIER ON 1/2" GLASS-
MAT GYP SHEATHING
FILL GAP BETWEEN
FRAMING AND PIPE
SLEEVE WITH
MINERAL WOOL BATT
PIPE OR CONDUIT
PENETRATING WALL
TYPICAL EXTERIOR WALL
SHOWN - SEE WALL SECTIONS
FOR PROJECT EXTERIOR WALL
COMPOSITION AND
DIMENSIONS
LOWER EAVE
26' - 0"
T.O.S. @ HAUNCH
27' - 4 7/64"
AIR BARRIER COMPONENT-
VAPOR IMPERMEABLE FACTORY
PREFINISHED INSULATED METAL
WALL PANEL (R 21 MINIMUM)
SYSTEM.
PREFINISHED ALUMINUM DOWN
SPOUT BEYOND
CONT. METAL GIRT BY PRE-
ENGINEERED METAL BUILDING
MANUFACTURER
PREFINSHED
ALUMINUM GUTTER
PREFINISHED METAL FASCIA WITH
CONT. CONCEALED CLEATS OVER
3/4" MARINE GRADE PLYWOOD
SHEATHING ON LIGHT GAUGE
FRAMING, TYP.
PREFINSHED METAL SOFFIT PANELS ON ON
LIGHT GAUGE METAL FRAMING @ 16" O.C., TYP.
CONT. BACKER ROD AND SEALANT
AT JOINT, TYP., COLOR TO MATCH
METAL PANELS
PREFINISHED METAL TRIM
CONT. METAL BEAM BY PRE-
ENGINEERED METAL BUILDING
MANUFACTURER
METAL PURLINS BY PRE-
ENGINEERED METAL BUILDING
MANUFACTURER
EAVE SUPPORT BY PRE-
ENGINEERED METAL BUILDING
MANUFACTURERCONT. BENT METAL EAVE
SUPPORT STRUT
1'
0"
A-500
1 3" THICK FACTORY PREFINISHED
PREINSULATED METAL WALL PANEL
(R 21 MINIMUM) SYSTEM.
Z-GIRTS BY PRE-ENGINEERED
METAL BUILDING
MANUFACTURER AT TOP,
MIDDLE AND BOTTOM OF
TRANSLUCENT PANEL
BENT FRAME BY PRE-
ENGINEERED METAL BUILDING
MANUFACTURER
BEAM BY PRE-ENGINEERED
METAL BUILDING MANUFACTURER
PREFINISHED METAL DRIP FLASHING
PREFINISHED METAL FLASHING W/
BEND FOR THERMAL MOVEMENT
METAL CLEAT
FLEXIBLE FLASHING
FILL CAVITY WITH BATT INSULATION
AIR BARRIER COMPONENT-
VAPOR IMPERMEABLE FACTORY
PREFINISHED PREINSULATED
METAL ROOF PANEL (R28
MINIMUM) SYSTEM
5/8" GLASS MAT GYP BD.
ATTACHED TO Z-PURLINS, PAINT
TO MATCH ADJACENT FINISHES
5/8" GLASS MAT GYP BD.
ATTACHED TO Z-PURLINS AND
LIGHT GAUGE METAL STUDS
@ 24" O.C., PAINT TO MATCH
ADJACENT FINISHES
DRIP
DRIP TO BE 1" QUARTER ROUND
OR MANUFACUTURER'S STANDARD DRIP
5/
8"
6 1/2"
3 1/2" 3"
5/
8" 1"
3/4" 1/2"
5 1/4"
JAMB CONDITION - ISO
1 3/4"
PRECAST
RETURN
PROJECTION AT
DOORS
CMU BASE
MTL WALL PANEL
JAMB CONDITION -
ELEVATION
TY
PI
C
AL
A T
H O
LL
O
W M
ET
AL
D O
O R
S
AN
D D
O O
R O
C
8"
CONT. BACKER
ROD AND
SEALANT JOINT
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\k6enxdao\Documents\FY18PN80855_ARCH_R18_k6enxdao.rvt
3/28/2018 11:27:42 AM
M
AR
C H
W
2H N
-1 8-
R -3
D es ig ne r
Au th or
Ap pr ov er
C
AT
C O
D E
A-321
W
AL
L D
ET
AI
LS
SA
VA
N N
AH
D
IS
TR
IC
T
Sa va nn ah
, G eo rg ia
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
TR
AI
N
IN
G
S U
PP
O
R T
FA
C
IL
IT
Y
PN
C he ck er
ISSUED FOR CONSTRUCTION
SCALE: 1 1/2"=1'-0"
6"6"
SCALE: 3"=1'-0"
04 2
SCALE: 1 1/2"=1'-0"
TYP. BOLLARD PLACEMENT DET.4TYPICAL DETAIL AT WALL BASE1
TYPICAL CMU CONTROL JOINT (CJ)3
TYPICAL EXTERIOR WALL PENETRATION6
TYPICAL DETAIL AT EAVE2 0
SCALE: 1 1/2"=1'-0"
1 2 42
SCALE: 1/2"=1'-0"
SECTION DETAIL - ROOF HI-LO TRANSITION5
SCALE: 1 1/2"=1'-0"
PRECAST CONCRETE COPING DETAILS7
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
M
AR
1 8
1. USE 5/8" GLASS MAT GYP BD AT ALL LOCATIONS
TYPICALLY. WHERE TILE IS TO BE USED OR OTHER
WET AREAS USE CEMENT BD WITH MEMBRANE IN
LIEU OF GLASS MAT. REFERENCE FINISH SCHEDULE
FOR TILE LOCATIONS. THESE REQUIREMENTS ARE
IN ADDITION TO TYPE 'X' REQUIREMENT AT RATED
WALLS.
2. USE HIGH IMPACT GYP BD IN ALL COMMON
AREAS, TO INCLUDE CORRIDORS, LOBBIES, AND
VESTIBULES, AND IN ALL STORAGE ROOMS.
3. SEE FINISH SCHEDULE FOR LOCATIONS WHERE
FIRE RETARDANT TREATED PLYWOOD ON GYP BD
WALL SURFACES ARE REQUIRED. THESE
REQUIREMENTS ARE IN ADDITION TO TYPE 'X'
REQUIREMENT AT RATED WALLS.
4. ALL FIRE RATED ASSEMBLIES SHALL COMPLY
WITH APPLICABLE UL DESIGN NUMBER FOR RATING
INDICATED.
5. METAL STUD SPACING FOR PARTITIONS SHALL
BE MAXIMUM 16" O.C. AT ALL LOCATIONS TO
RECEIVE CERAMIC TILE WALL FINISH AND MAXIMUM
24" O.C. AT ALL OTHER LOCATIONS U.N.O.
6. ALL WALLS FORMING THE PERIMETER OF THE
BUILDING ENVELOPE SHALL BE EXTENDED TO THE
UNDERSIDE OF THE ROOF DECK AND SEALED AT
TOP AND BOTTOM ON BOTH SIDES OF WALL.
7. SOME STUD WALLS WILL CONTAIN PLUMBING
AND MAY REQUIRE CUTTING, SPLICING, AND
REINFORCING OF THE STUDS. REFER TO
MECHANICAL FOR PLUMBING LOCATIONS AND
STRUCTURAL FOR STUD FRAMING REQUIREMENTS.
STRUCTURAL INTEGRITY OF STUDS MUST BE
MAINTAINED.
8. MINIMUM GAUGE OF INTERIOR STUDS SHALL BE
AS FOLLOWS U.N.O.:
20 GA. FOR NON-LOADBEARING PARTITIONS UP TO
17-FT ABOVE SLAB
-- 16 GA. MIN. FOR 20-FT ABOVE SLAB
-- 12 GA. MIN. FOR 24-FT
- REFERENCE SPECIFICATIONS FOR MINIMUM
GAUGE OF STUDS AT HEADERS AND OPENINGS
9. PROVIDE SOLID BLOCKING AT ALL WALL-
MOUNTED ITEMS INCLUDING BUT NOT LIMITED TO
TOILET ACCESSORIES, WALL STOPS, AND
FIXTURES.
10. ALL PENETRATIONS INTO STC RATED AREAS
(WALLS, CEILINGS, FLOORS) SHALL BE SEALED
BOTH SIDES.
11. WHERE NO CEILING IS SCHEDULED, EXTEND
WALL TO UNDERSIDE OF DECK U.N.O.
CEILING
PLAN
BASE
ROOF DECK
CONTINUOUS SEALANT BOTH SIDES
DEFLECTION TRACK
SCHEDULED CEILING
ONE LAYER 5/8" GYPSUM WALL
BOARD EACH FACE
METAL STUDS AT 16" O.C.
UNLESS OTHERWISE NOTED, REFER
TO WALL TYPE FOR STUD SIZE
CONTINUOUS SEALANT BOTH SIDES
TOP OF STRUCTURAL
SLAB
CONTINUOUS RUNNER
PARTITION TYPE 'A'- NON FIRE RATED
A: 6" MTL. STUDS, 5/8" GYP. BD. BOTH SIDES
A1: 6" MTL. STUDS, 5/8" GYP. BD. 1 SIDE
A2: 3 5/8" MTL. STUDS, 5/8" GYP. BD. 1 SIDE
A3: 2 1/2" MTL. STUDS, 5/8" GYP. BD. 1 SIDE
(REFER TO PLAN LOCATIONS AND FINISH
SCHEDULE FOR SOUND BATT LOCATIONS)
CEILING
PLAN
BASE
SCHEDULED CEILING
ONE LAYER 5/8" CEMENTITIOUS
WALL BOARD
METAL STUDS AT 16" O.C.
UNLESS OTHERWISE NOTED
CONTINUOUS FIRE/SMOKE
STOP SEALANT BOTH SIDES
TOP OF STRUCTURAL
SLAB
CONTINUOUS RUNNER
CERAMIC TILE WHERE SCHEDULED
6"
PARTITION TYPE 'B'-
NON FIRE RATED PARTITION,
B: 6" MTL. STUDS, 5/8" GYP. BD. 2 SIDES W/ CERAMIC TILE 1 SIDE
B1: 6" MTL. STUDS, 5/8" GYP. BD. 1 SIDE W/ CERAMIC TILE
B2: 2 1/2" MTL. STUDS, 5/8" GYP. BD. 1 SIDE W/ CERAMIC TILE
(REFER TO PLAN LOCATIONS AND FINISH
SCHEDULE FOR SOUND BATT LOCATIONS)
WALL TYPE B: ONE LAYER 5/8"
GYPSUM WALL BOARD ON
CORRIDOR SIDE
CEILING
PLAN
BASE
ROOF DECK
CONTINUOUS FIRE/SMOKE
STOP SEALANT BOTH SIDES
REFER TO SYSTEM NO. HW-D-0488
FOR HEAD OF WALL DETAIL
SCHEDULED CEILING
ONE LAYER 5/8" GYPSUM WALL
BOARD EACH FACE. PROVIDE TYPE
X AT PARTITION TYPES C, C1
CMU, REFER TO WALL TYPES FOR
NOM. SIZES UNLESS OTHERWISE
NOTED
CONTINUOUS FIRE/SMOKE
STOP SEALANT BOTH SIDES
TOP OF STRUCTURAL
SLAB
CONTINUOUS RUNNER
C: 12" NOM. CMU (1 HR RATED UL U#907) W/ WALL TYPE 'F' TO DECK
C1: 12" NOM. CMU W/ 7/8" HAT CHANNELS AND 5/8" GYP. BD. 1 SIDE
(1 HR RATED UL U#907) W/ WALL TYPE 'F' ABOVE TO DECK
WALL TYPES 'C' AND 'C1': CMU RATED 1 HR, PER MIN. EQUIVALENT THICKNESS PER IBC
TABLE 721.3.2. 2.7 MIN. CMU THICKNESS REQUIRED BLOCK SHALL BEAR U.L.
CLASSIFICATION MARKINGS
6"
SOUND BATTS(OMITTED IN
WALL TYPES
'C2' AND 'C3') 1 LAYER 5/8" TYPE X GYP.
BD. EA. SIDE
SEAL EA. SIDE W/ FIRE
RATED SEALANT
FOR WALL
TYPE 'F'
INFO SEE
SHEET
A-702
UL# U465
F
PLAN
BASE
8" METAL STUDS AT 16" O.C.
UNLESS OTHERWISE NOTED
CONTINUOUS SEALANT
TOP OF STRUCTURAL
SLAB
CONTINUOUS RUNNER
PARTITION TYPE 'D'-
CORRUGATED METAL WAINSCOT
TOP
R 13 BATT INSULATION,
BETWEEN LIGHT GAUGE
METAL STUDS @ 16" O.C.,
MAX.
EXTERIOR WALL ASSEMBLY, W1
CONT. METAL GIRT BY PRE-
ENGINEERED METAL BUILDING
MANUFACTURER
8" METAL STUDS @ 24" O.C.,
NOTCHED AROUND GIRTS
METAL TRIM W/ HEMMED EDGE
CORRUGATED METAL
AP
PR
O X.
PLAN
BASE
CONTINUOUS ACOUSTICAL SEALANT
TOP OF STRUCTURAL
SLAB
CONTINUOUS RUNNER
PARTITION TYPE 'E'-
CORRUGATED METAL FINISH AT CLASSROOM WALLS
UPPER
SOUND BATT INSULATION
BETWEEN METAL STUDS.
METAL STUDS @ 16" O.C.
CORRUGATED METAL
6"
CEILING AS SCHEDULED
4"
BASE AS SCHEDULED
E: 6" MTL. STUDS @ 16" O.C., W/ 5/8" GYP. BD. ON BOTH SIDES, W/
7/8" HAT CHANNELS ON STORAGE BAY SIDE AND CORRUGATED
METAL PANELS
E1: SAME AS 'E' BUT OMIT 5/8" GYP. BD. ON INSIDE
GYP BD. SHEATHING
HAT CHANNELS @ 24" O.C. VERTICAL
HAT CHANNELS @ 24" O.C. VERTICAL
AIR BARRIER COMPONENT-
VAPOR IMPERMEABLE
FACTORY PREFINISHED
INSULATED METAL WALL
PANEL (R 21 MINIMUM)
SYSTEM.
FINISHED CEILING
AS SCHEDULED
EXTERIOR INTERIOR
LINE OF BENT FRAME
BEYOND
PLAN
SECTION
CONT. METAL GIRT BY
PRE-ENGINEERED METAL
BUILDING MANUFACTURER
LINE OF GIRTS
ABOVE/BELOW
EXTERIOR INTERIOR
LINE OF BENT FRAME
BEYOND
PLAN
SECTION
CONT. METAL GIRT BY
PRE-ENGINEERED METAL
BUILDING MANUFACTURER
NOM. 4" SPLIT-FACED CMU
BASE, RUNNING BOND
2 INCH CAVITY
SEMI-IMPERMEABLE
AIR/WEATHER RESISTIVE
BARRIER OVER 5/8" GLASS
MAT GYPSUM SHEATHING
R 13 BATT INSULATION,
BETWEEN LIGHT GAUGE
METAL STUDS @ 16" O.C., MAX.
2 1/2 INCH THICK CAVITY WALL
MINERAL WOOL INSULATION
BOARD R10 MINIMUM
TOP OF
STRUCTURAL
SLAB
CONTINUOUS RUNNER
8" MTL. STUDS @ 16" O.C.,
NOTCHED AROUND GIRTS
INTERIOR FINISH
MATERIAL
EXTERIOR INTERIOR
LINE OF BENT FRAME
BEYOND
PLAN
SECTION
CONT. METAL GIRT BY
PRE-ENGINEERED METAL
BUILDING MANUFACTURER
NOM. 4" SPLIT-FACED CMU
BASE, RUNNING BOND
2 INCH CAVITY
SEMI-IMPERMEABLE
AIR/WEATHER RESISTIVE
BARRIER OVER 5/8" GLASS
MAT GYPSUM SHEATHING
R 13 BATT INSULATION,
BETWEEN LIGHT GAUGE
METAL STUDS @ 16" O.C., MAX.
2 1/2 INCH THICK CAVITY WALL
MINERAL WOOL INSULATION
BOARD R10 MINIMUM
TOP OF
STRUCTURAL
SLAB
CONTINUOUS RUNNER
8" MTL. STUDS @ 16" O.C.,
NOTCHED AROUND GIRTS
INTERIOR FINISH
MATERIAL
METAL SOFFIT PANELS
BLOCKING
W
AL
L M
AT
ER
IA
LS
E
XT
EN
D
T O
U N
D
ER
SI
D
E O
F D
EC
K
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\k6enxdao\Documents\FY18PN80855_ARCH_R18_k6enxdao.rvt
3/28/2018 11:44:17 AM
M
AR
C H
W
2H N
-1 8-
R -3
D es ig ne r
Au th or
Ap pr ov er
C
AT
C O
D E
A-510
W
AL
L / P
AR
TI
TI
O
N T
YP
ES
SA
VA
N N
AH
D
IS
TR
IC
T
Sa va nn ah
, G eo rg ia
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
TR
AI
N
IN
G
S U
PP
O
R T
FA
C
IL
IT
Y
PN
C he ck er
ISSUED FOR CONSTRUCTION
WALL TYPE NOTES
SCALE: 1 1/2"=1'-0"
WALL TYPE 'A', 'A1', 'A2', 'A3'1
WALL TYPE 'B', 'B1', 'B2'2
WALL TYPES 'C', 'C1'3
WALL TYPES 'D', D1'4
WALL TYPES 'E', 'E1'5 EXTERIOR WALL TYPE 27
EXTERIOR WALL TYPE 16 EXTERIOR WALL TYPE 38
NOTE: FOR WALL TYPE 'F' SHOWN
IN DETAIL 2-A302 SEE: SHEET
A-702
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
M
AR
1 8
MASONRY UNITS, REFER TO WALL
TYPES FOR TYPE AND THICKNESS
CEILING AS SPECIFIED WITH
SUSPENSION SYSTEM
STOREFRONT DOOR FRAME
AS SCHEDULED.
BACKER ROD AND SEALANT
R 13 BATT INSULATION
5/8" THICK GLASS MAT GYPSUM
WALL BOARD
P.T. WOOD BLOCKING
SEALANT
STOREFRONT DOOR AS
SCHEDULED
NOTE: SEE A-800 SERIES PLATES FOR
AIR BARRIER GUIDANCE
PREFINISHED METAL
DRIP FLASHING
CMU JAMB (BEYOND)
WEEPS @ 32" O.C. MAX.
ADJUSTABLE MASONRY WALL TIES
RIGID INSULATION OVER
CONTROL LAYER ON 5/8" EXT.
GYP. BD. SHEATHING
RUN CONTROL LAYER OVER TOP
OF FLEXIBLE MEMBRANE (PEEL
AND STICK) LAID OVER
TERMINATION BAR
CONT. THRU-WALL FLASHING W/ END
DAMS, RUN UP FACE OF EXT. GYP.
BD. AND PROVIDE STAINLESS STEEL
TERMINATION BAR AND SEALANT
MORTAR NET
MIN. R-13 BATT
INSULATION BETWEEN
METAL STUDS AND GIRTS
P.T. WOOD BLOCKING
CONT. SEALANT
AROUND PERIMETER
OF FRAME, TYP.
STOREFRONT DOOR FRAME
AS SCHEDULED. PROVIDE 3
JAMB ANCHORS PER JAMB
STOREFRONT DOOR AS
SCHEDULED
NOTE: SEE A-800 SERIES PLATES
FOR AIR BARRIER GUIDANCE
PAINTED GYP BD.
INTERIOR FINISH
8" METAL STUDS AND
TRACK AT HEAD AND
JAMBS, FILL STUD CAVITY
WITH MINERAL WOOL
INSULATION
MASONRY UNITS, REFER TO
WALL TYPES FOR TYPE &
THICKNESS
RIGID INSULATION BOARD
CONTINUOUS LIQUID APPLIED
CONTROL LAYER
5/8" THICK GLASS MAT GYPSUM
SHEATHING
BACKER ROD AND SEALANT
STEEL CHANNEL, REFER
TO STRUCTURAL
FLEXIBLE MEMBRANE
FLASHING, TURN CORNER
INTO ROUGH OPENING
1"
STOREFRONT DOOR FRAME
AS SCHEDULED. PROVIDE 3
JAMB ANCHORS PER JAMB
STOREFRONT DOOR AS
SCHEDULED
NOTE: SEE A-800 SERIES PLATES
FOR AIR BARRIER GUIDANCE
LINE OF MASONRY UNITS BELOW
CONT. BACKER ROD AND SEALANT P.T. WOOD BLOCKING
CONT. SEALANT
AROUND PERIMETER
OF FRAME, TYP.
NOTE: SEE A-800 SERIES PLATES
FOR AIR BARRIER GUIDANCE
FACTORY PREFINISHED INSULATED
METAL COMPOSITE WALL PANEL
(R 21 MINIMUM)
8" METAL STUDS AND
TRACK AT HEAD AND
JAMBS, FILL STUD CAVITY
WITH MINERAL WOOL
INSULATION
LINE OF PRECAST CONCRETE CAP
STONE RETURN BELOW, HIDDEN
BELOW METAL WALL PANEL
8"
6 3/4" 3"
MIN. R-13 BATT
INSULATION BETWEEN
METAL STUDS AND GIRTS
PAINTED GYP BD.
INTERIOR FINISH
STAINLESS STEEL DRIP EDGE
BACKER ROD AND SEALANT
NOTE: SEE A-800 SERIES PLATES FOR
AIR BARRIER GUIDANCE
FACTORY PREFINISHED INSULATED
METAL COMPOSITE WALL PANEL
(R 21 MINIMUM)
8" METAL STUDS AND TRACK AT
HEAD AND JAMBS, FILL STUD
CAVITY WITH MINERAL WOOL
INSULATION
STOREFRONT DOOR FRAME
AS SCHEDULED.
STOREFRONT DOOR AS
SCHEDULED
CEILING AS SPECIFIED WITH
SUSPENSION SYSTEM
R 13 BATT INSULATION
5/8" THICK GLASS MAT GYPSUM
WALL BOARD
P.T. WOOD BLOCKING
SEALANT
DOOR AS
SCHEDULED
STOREFRONT
FRAME BEYOND
ADA COMPLIANT
ALUM. THRESHOLD
SET IN FULL MASTIC
BED
NEOPRENE DOOR
SWEEP ATTACHED
TO BOTTOM OF
DOOR
GYP. BD. FINISH
BEYOND
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\k6enxdao\Documents\FY18PN80855_ARCH_R18_k6enxdao.rvt
3/28/2018 11:28:19 AM
M
AR
C H
W
2H N
-1 8-
R -3
D es ig ne r
Au th or
Ap pr ov er
C
AT
C O
D E
A-603
D O
O R
D
ET
AI
LS
EX
TE
R
IO
R
II
SA
VA
N N
AH
D
IS
TR
IC
T
Sa va nn ah
, G eo rg ia
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
TR
AI
N
IN
G
S U
PP
O
R T
FA
C
IL
IT
Y
PN
C he ck er
ISSUED FOR CONSTRUCTION
EXT. SF DOOR HEAD @ CMU1
EXT. SF DOOR JAMB2
EXT. SF DOOR JAMB @ MTL PANEL3
SCALE: 1 1/2"=1'-0"
EXT. SF DOOR HEAD @ METAL4
ALUMINUM SILL5
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
M
AR
1 8
2" R
EF
. S
C H
ED
HOLLOW METAL
DOOR FRAME
AS SCHEDULED
HOLLOW METAL
DOOR AS
SCHEDULED
VARIES- REF. PARTITION TYPES
GYPSUM BOARD PARTITION -SEE PLANS FOR
PARTITION TYPE
SOUND ATTENTUATION BATTS IF APPLICABLE,
VERIFY WITH PARTITION TYPES
CAULKING AT
GYPSUM
BOARD, 1/4" BUTT
JOINT
PROVIDE CAULK AT
CERAMIC TILE (SEE
FINISH SCHEDULE)
BOX HEADER AT OPENING
NOTE:
SEE PARTITION TYPES FOR
WALL THICKNESS AND FOR
NUMBER OF LAYERS, THICKNESS
AND TYPE OF GYPSUM BOARD,
CEMENT BOARD. SEE FINISH
SCHEDULE FOR TILE LOCATIONS
NOTE: SEE A-800 SERIES PLATES FOR AIR
BARRIER GUIDANCE
2" R
EF
. S
C H
ED
HOLLOW METAL
DOOR FRAME
AS SCHEDULED
PROVIDE (3) JAMB
CLIPS PER JAMB
HOLLOW METAL
DOOR AS
SCHEDULED
VARIES- REF. PARTITION TYPES
GYPSUM BOARD PARTITION-SEE
PLANS FOR PARTITION TYPE
SOUND ATTENTUATION BATTS IF APPLICABLE,
VERIFY WITH PARTITION TYPES
CAULKING AT
GYPSUM
BOARD, 1/4" BUTT
JOINT
PROVIDE CAULK AT
CERAMIC TILE (SEE
FINISH SCHEDULE)
DOUBLE METAL STUDS
AT JAMBS
NOTE:
SEE PARTITION TYPES FOR
WALL THICKNESS AND FOR
NUMBER OF LAYERS, THICKNESS
AND TYPE OF GYPSUM BOARD,
CEMENT BOARD. SEE FINISH
SCHEDULE FOR TILE LOCATIONS
NOTE: SEE A-800 SERIES PLATES FOR AIR
BARRIER GUIDANCE
HOLLOW METAL
DOOR AND
FRAME AS
SCHEDULED FLOOR FINISH AS SCHEDULED
BOTH SIDES
MOLDING/ THRESHOLD AS
REQUIRED FOR CHANGES
IN FLOOR FINISHES
CONCRETE SLAB
SEE STRUCTURAL
NOTE: SEE A-800 SERIES PLATES FOR AIR
BARRIER GUIDANCE
HOLLOW METAL
DOOR AND
FRAME AS
SCHEDULED
FLOOR FINISH AS SCHEDULED
BOTH SIDES1/
2" M
AX
MARBLE THRESHOLD
CONCRETE SLAB
SEE STRUCTURAL
NOTE: SEE A-800 SERIES PLATES FOR AIR
BARRIER GUIDANCE
R
EF
. S C
H
ED
HOLLOW METAL
DOOR FRAME
AS SCHEDULED
VARIES- REF. PARTITION TYPES
GYPSUM BOARD PARTITION -SEE PLANS FOR
PARTITION TYPE
SOUND ATTENTUATION BATTS IF APPLICABLE,
VERIFY WITH PARTITION TYPES
CAULKING AT
GYPSUM
BOARD, 1/4" BUTT
JOINT
PROVIDE CAULK AT
CERAMIC TILE (SEE
FINISH SCHEDULE)
BOX HEADER AT OPENING
NOTE:
SEE PARTITION TYPES FOR
WALL THICKNESS AND FOR
NUMBER OF LAYERS, THICKNESS
AND TYPE OF GYPSUM BOARD,
CEMENT BOARD. SEE FINISH
SCHEDULE FOR TILE LOCATIONS
2"
R
EF
. S C
H
ED
HOLLOW METAL
CASED OPENING
FRAME AS
SCHEDULED
PROVIDE (3) JAMB
CLIPS PER JAMB
VARIES- REF. PARTITION TYPES
GYPSUM BOARD PARTITION-SEE
PLANS FOR PARTITION TYPE
SOUND ATTENTUATION BATTS IF APPLICABLE,
VERIFY WITH PARTITION TYPES
CAULKING AT
GYPSUM
BOARD, 1/4" BUTT
JOINT
PROVIDE CAULK AT
CERAMIC TILE (SEE
FINISH SCHEDULE)
DOUBLE METAL STUDS
AT JAMBS
NOTE:
SEE PARTITION TYPES FOR
WALL THICKNESS AND FOR
NUMBER OF LAYERS, THICKNESS
AND TYPE OF GYPSUM BOARD,
CEMENT BOARD. SEE FINISH
SCHEDULE FOR TILE LOCATIONS
2"
HOLLOW METAL
CASED OPENING
FRAME AS
SCHEDULED FLOOR FINISH AS SCHEDULED
BOTH SIDES
MOLDING/ THRESHOLD AS
REQUIRED FOR CHANGES
IN FLOOR FINISHES
CONCRETE SLAB
SEE STRUCTURAL
1'-0"
9"
2"
EXTERIOR WALL ASSEMBLY
2" DIA. X 3' TALL PAINTED
STEEL PIPE BOLLARD
AT INSULATED STEEL DOOR AT ALUMINUM STOREFRONT DOORS
100A AND 10OC
2' -1
/2
MIN
7 1/2"
NOTE: THIS DETAIL INDICATES TYPICAL BOLLARD LOCATIONS, UNLESS
OTHERWISE INDICATED ON FLOOR PLAN SHEETS
EXTERIOR WALL ASSEMBLY
T1TOP OF CONCRETE
FLOOR SLAB
1/2" TILE OR 1/2"
THICK QUARRY
TILE OR CARPET
TILES OR RUBBER
FLOORING
TRANSITION
STRIP(MARBLE
THRESHOLD AT
RESTROOMS)
DOOR
BIOTILE OR
CARPET
1/2" EXT JT MAT
RECESSED MAT WHERE INDICATED,
SEE PLANS
ALUMINUM THRESHOLD SET IN
FULL BED OF SEALANT
EDGE OF CURTAIN WALL BEYOND
(SEE FLOOR PLAN FOR LOCATION)
1/2" EXT JT MAT
CONCRETE SIDEWALK ON GRADE
DOOR SWEEP
ALUMINUM THRESHOLD
SET IN FULL BED OF SEALANT
FLOOR FINISH AS SCHEDULED
CONCRETE SIDEWALK ON
GRADE; 2% SLOPE ON MAX.
DOOR SWEEP
DOOR FRAME BEYOND
T3
T4
/1 6"
W /O
D R
AI
N
7/
8" W
/O D
R
AI
N
3/
" W
IT
H D
R
AI
N
1/ 4"
M
AX
1/ 4"
M
AX
TOP OF CONCRETE
FLOOR SLABT2
DOOR
3/8" THICK
PORCELAIN TILE OR
1/2" QUARRY TILE
TRANSITION STRIP
3/8" THICK
PORCELAIN TILE OR
1/2" QUARRY TILE
T5
DOOR SWEEP
ALUMINUM THRESHOLD
SET IN FULL BED OF SEALANT
FLOOR FINISH AS SCHEDULED
DOOR FRAME
BEYOND
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\k6enxdao\Documents\FY18PN80855_ARCH_R18_k6enxdao.rvt
3/28/2018 11:29:14 AM
M
AR
C H
W
2H N
-1 8-
R -3
D es ig ne r
Au th or
Ap pr ov er
C
AT
C O
D E
A-604
D O
O R
D
ET
AI
LS
IN
TE
R
IO
R
I
SA
VA
N N
AH
D
IS
TR
IC
T
Sa va nn ah
, G eo rg ia
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
TR
AI
N
IN
G
S U
PP
O
R T
FA
C
IL
IT
Y
PN
C he ck er
ISSUED FOR CONSTRUCTION
SCALE: 1 1/2"=1'-0"
SCALE: 1 1/2"=1'-0"
SCALE: 1 1/2"=1'-0"
SCALE: 1 1/2"=1'-0"
SCALE: 1 1/2"=1'-0"
SCALE: 1 1/2"=1'-0"
SCALE: 1 1/2"=1'-0"
INTERIOR DOOR HEAD DETAIL1
INTERIOR DOOR JAMB DETAIL2
INTERIOR DOOR SILL DETAIL3
INT.DOOR SILL DETAIL AT TILE4
INTERIOR DOOR HEAD DETAIL AT CASED OPENING5
INTERIOR DOOR JAMB DETAIL AT CASED OPENING6
INTERIOR DOOR SILL DETAIL AT CASED OPENING7
TYPICAL BOLLARD LOCATION DETAILS8
THRESHOLD DETAILS9
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
M
AR
1 8
FINISH LEGEND
ACOUSTICAL CEILING TILE
AT-1: USG; Mars ClimaPlus, 86785, White, 2'x2'
CORNER GUARD
CG-1: CS Acrovyn; Driftwood #262
GROUT
GR-1: Custom Building Products #60 Charcoal
GR-2: Custom Building Products #14 White Dove
OPERABLE PARTITION
PT-1: Sherwin Williams; SW7015 Repose Gray
PT-2: Sherwin Williams; SW6244 Naval
PT-3: Sherwin Williams; SW7007 Ceiling Bright White
PCT-1: Trinity Tile; Thru Color Porcelain;
Cosmic, Nero; 12"x12" tile
TOILET PARTITIONS
TP-1: Accurate Solid Phenolic Graphite Graphix 3020 Stainless Steel Hardware
PT-4: Sherwin Williams; SW7019 Gauntlet Gray
CARPET
CPT-1: Mohawk; Relative Degree, Modify 979; 24"x24" Tile; Quarter-Turn Installation
CERAMIC TILE
CT-1: Trinity Tile; Cascata, White Gloss; 4"x16" Tile
ENTRANCE MAT
EM-1: C/S Pedimat Monotuft HD Frame: Clear Anodized Insert: 7321 Wrought Iron
PORCELAIN TILE
RESILIENT BASE
RB-1: Allstate; A43
SOLID SURFACING
SS-1: Wilsonart Solid Surface;
Frosty White 1573SL (1)
PAINT
OP-1: Panelfold; Vinyltex, Savory, Taro
AT-2: Nudo; Fiberlite FRP Ceiling Panels;
Embossed, White (50)
METAL WALL PANEL
MWP-1: Standard Finish, Natural Material
PCT-1; 6"X12" Cove Base
CT-1; 4"X16" Wall Tile
9' -0
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENXVDR\Documents\FY18PN80855_INT_R18_K6ENXVDR.rvt
3/28/2018 11:39:15 AM
M
AR
C H
W
2H N
-1 8-
R -3
VD
R
TJ
D
C
AT
C O
D E
I-611
R O
O M
F
IN
IS
H
S C
H
ED
U
LE
, F
IN
IS
H
L
EG
EN
D
D
ET
AI
LS
SA
VA
N N
AH
D
IS
TR
IC
T
Sa va nn ah
, G eo rg ia
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
TR
AI
N
IN
G
S U
PP
O
R T
FA
C
IL
IT
Y
PN
ISSUED FOR CONSTRUCTION
ROOM FINISH SCHEDULE
ROOM NO ROOM NAME
WALL FINISH BASE FINISH FLOOR CEILING
NOTES & REMARKS (SEE NOTES)NORTH EAST SOUTH WEST NORTH EAST SOUTH WEST FIN. MAT. HEIGHT 100AB VESTIBULE PNT-1 PNT-1 PNT-1 PNT-1 PCT-1 PCT-1 PCT-1 PCT-1 PCT-1 AT-1 10'-0" 3 100CD VESTIBULE PNT-1 PNT-1 PNT-1 PNT-1 PCT-1 PCT-1 PCT-1 PCT-1 PCT-1 AT-1 10'-0" 3 101 STORAGE BAY EXPOSED PNT-2/MWP-1 EXPOSED EXPOSED RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE EXPOSED 0" 1 101A CORRIDOR PNT-2 PNT-1 PNT-2 PNT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE AT-1 10'-4" 2
102 JAN PNT-1 PNT-1 PNT-1 PNT-1 PCT-1 PCT-1 PCT-1 PCT-1 PCT-1 PNT-3 9'-0" 3
103 WOMEN'S PNT-1/CT-1 PNT-1/CT-1 CT-1 PNT-1/CT-1 PCT-1 PCT-1 PCT-1 PCT-1 PCT-1 PNT-3 9'-0" 3, 10
103A JAN PNT-1 PNT-1 PNT-1 PNT-1 PCT-1 PCT-1 PCT-1 PCT-1 PCT-1 PNT-3 9'-0" 3
104 MEN'S CT-1 PNT-1/CT-1 PNT-1/CT-1 PNT-1/CT-1 PCT-1 PCT-1 PCT-1 PCT-1 PCT-1 PNT-3 9'-0" 3, 10 105 STORAGE PNT-1 PNT-1 PNT-1 PNT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE AT-1 9'-0"
106 OFFICE PNT-1 PNT-1 PNT-1 PNT-1 RB-1 RB-1 RB-1 RB-1 CPT-1 AT-1 9'-0" 4
107 CLASSROOM A PNT-1 PNT-1 PNT-1 PNT-2 RB-1 RB-1 RB-1 RB-1 CPT-1 AT-1 / PNT-3 12'-8" 4 108 CLASSROOM B PNT-1 PNT-1 PNT-1 PNT-2 RB-1 RB-1 RB-1 RB-1 CPT-1 AT-1 / PNT-3 12'-8" 4 109 STORAGE A/V PNT-1 PNT-1 PNT-1 PNT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE AT-1 9'-0" 110 MAIN T/R PNT-1 PNT-1 PNT-1 PNT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE EXPOSED 0" 111 F/A CAT TV PNT-1 PNT-1 PNT-1 PNT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE AT-1 8'-6"
112 MISC. PNT-1 PNT-1 PNT-1 PNT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE AT-1 9'-0"
113 ELECTRICAL ROOM EXPOSED EXPOSED PNT-1 PNT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE EXPOSED 0" 114 MECHANICAL ROOM PNT-1 EXPOSED PNT-1 PNT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE EXPOSED 0"
1. MWP-1 IS CORRUGATED METAL WALL PANEL. LOCATIONS AS
SPECIFIED IN A-PLATES. FINISH SHALL BE MANUFACTURER'S
ORIGINAL UNPAINTED FINISH. EAST WALL OF STORAGE BAY
SHALL BE PNT-2 (ACCENT COLOR) AND MWP-1. ALL CHIP WALLS
SHALL BE PNT-1.
2. PNT-2 SHALL ONLY BE USED ON THE NORTH AND SOUTH
WALLS OF CORRIDOR 101A THAT ARE ADJACENT TO THE
STORAGE BAY.
3. PCT-1 SHALL BE INSTALLED IN A STRAIGHT-LAY PATTERN.
4. CPT-1 SHALL BE INSTALLED USING A QUARTER-TURN
INSTALLATION METHOD.
5. REFERENCE SPECIFICATION SECTION 09 06 00 "SCHEDULE
FOR FINISHES" FOR INFORMATION REGARDING COLOR &
FINISH.
6. PRIOR TO CONSTRUCTION, ALL EXTERIOR & INTERIOR
COLORS SHALL BE SUBMITTED FOR APPROVAL PER
DIRECTIONS IN SPECIFICATION 09 06 90.
7. PROVIDE CORNER GUARDS AS SPECIFIED ON A-PLATES.
8. PAINT ALL SUPPLY & RETURN AIR MECHANICAL GRILLS /
DIFFUSERS ON GWB CEILINGS & WALLS TO MATCH ADJACENT
COLOR.
9. PAINT ALL EXPOSED STRUCTURE TO MATCH ADJACENT
MATERIAL.
10. CT-1 SHALL BE INSTALLED FULL HEIGHT ON THE NORTH
WALL OF THE MEN'S RESTROOM (BEHIND SINKS), AND THE
SOUTH WALL OF THE WOMEN'S RESTROOM (BEHIND SINKS).
THE REMAINING WALLS OF BOTH RESTROOMS SHALL HAVE A 6'
WAINSCOT, USING WALL TILE PATTERN BELOW, WITH
BULLNOSE TRIM.
GENERAL NOTES
3/4" = 1'-0"I-611
1 WALL TILE PATTERN
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
M
AR
1 8
NOTES, POWER ONE-LINE DIAGRAM:
1. FLINT EMC SHALL FURNISH AND INSTALL THE TRANSFORMER, TRANSFORMER PAD, AND PRIMARY DISTRIBUTION TIE-IN CONNECTION. FLINT EMC SHALL ALSO MAKE THE SECONDARY CONNECTIONS TO THE
TRANSFORMER.
2. THE CONTRACTOR SHALL FURNISH AND INSTALL THE SECONDARY CONDUCTORS AND CONDUITS FROM THE ENCLOSED CIRCUIT BREAKER (ECB-04) TO THE SECONDARY COMPARTMENT OF THE TRANSFORMER. THE CABLES SHALL BE OF SUFFICIENT LENGTH TO FACILIATE THEIR CONNECTION TO THE SECONDARY LUGS OF THE TRANSFORMER BY FLINT EMC. PROVIDE PIPE SLEEVES IN FOUNDATION FOR CONDUITS AT THE TIME OF CONSTRUCTION OF THE FOUNDATION. NO DRILLING OR PUNCHING THROUGH THE FOUNDATION WILL BE
ALLOWED.
3. PROVIDE PANELBOARD METERING DEVICES FOR PANELS AS SHOWN. THE METERS SHALL MEASURE, KWH, POWER FACTOR PER PHASE, AMP PER PHASE, KW DEMAND(WITH PEAK DATE & TIME), REAL-TIME LOAD IN KW AND VOLTS PER PHASE. THE METERS SHALL HAVE DATA STORED IN 15 MIN. FOR UP TO 72 DAYS OR 5-MINUTE INTERVALS FOR UP TO 24 DAYS. THE METERS SHALL TRANSMIT DATA AT LEAST DAILY. THE METERS SHALL COMPLY WITH NEMA C12.1. PROVIDE A 4-PAIR CAT 6 CABLE IN 1-INCH CONDUIT FROM THE PANELBOARD METER TO THE DIRECT DIGITAL CONTROL (DDC) PANEL AND A 4-PAIR CAT 6 CABLE IN 1-INCH CONDUIT FROM THE DDC CONTROL PANEL TO THE MAIN COMM. ROOM TO TRANSMIT METERED DATA TO THE BASEWIDE UTILITY MONITORING AND CONTROL SYSTEM (UMCS). COORDINATE THE INTERFACE COMPATIBILITY REQUIREMENTS
WITH THE BASE UMCS MANAGER THROUGH THE COR.
4. COORDINATE THE SETTING OF THE TRANSFORMER PRIMARY TAPS WITH FLINT EMC TO PROVIDE 480 VOLTS AT THE MDP BUS WHEN THE BUILDING IS UNDER NORMAL LOAD. THE TAP CHANGER ALLOWS FOR A 5% RAISE OR LOWERING OF THE VOLTAGE IN 2-1/2% INCREMENTS. THE TAP CHANGER IS A NO LOAD UNIT AND WILL REQUIRE
DE-ENERGIZING THE TRANSFORMER BEFORE THE TAPS CAN BE RAISED OR LOWERED.
5. PROVIDE PIPE SLEEVES FOR POWER AND COMMUNICATIONS ENTRANCE AND EXIT CONDUITS THROUGH THE FOUNDATION AT THE TIME OF THE CONSTRUCTION OF THE FOUNDATION. NO DRILLING OR PUNCHING THROUGH
THE FOUNDATION WILL BE ALLOWED.
MDP
480Y/277V
3 PH, 4 WIRE
800A, 42K AIC
700A
SHUNT TRIP
CIRCUIT
BREAKER
PANEL
HP1
4#600, #2G, 4"C
PANEL
HP2
4#1/0, #6G, 2"C
DT1 - 112.5 kVA
DRY TYPE
TRANSFORMER
480V- 208Y/120V
3 PH, 4 WIRE
Z = 5.1% X/R = 1.4
+ 5% TAP ON SECONDARY
PANEL
DPL
3#2/0, #6G, 2"C
4#300, #4G, 3"C
4#1, #6G, 2"C
4#2, #6G, 1'-1/2"C
SEE SHEET ES501
FOR MORE DETAILSMTS
800 AMP
3-POLE
35KA AIC
NEMA 3R
400 A 100 A 175A
4#4/0, #4G, 3"C
PANEL
EP
4#3/0, #2G, 2-1/2"C
6. ROUTING SHOWN ON RISER IS NOT MANDATORY. ROUTE CONDUIT AS NECESSARY TO AVOID
CONFLICTS.
7. PROVIDE A COMPUTER GENERATED 11"X17" POWER ONE-LINE DIAGRAM WALL-MOUNTED IN THE ELECTRICAL ROOM. THE ONE- LINE DIAGRAM SHALL BE CURRENT AS OF THE BENEFICIAL OCCUPANCY DATE. THE DIAGRAM SHALL INCLUDE ALL FEEDER AND CONDUIT SIZES AND QUANTITIES. THE ONE-LINE DIAGRAM SHALL BE MOUNTED IN RIGID PLEXIGLASS OR OTHER APPROVED PROTECTIVE MATERIAL AND
THE LOCATION SHALL BE COORDINATED WITH THE COR.
8. THE IMPEDANCE VALUE (%Z) IS PROVIDED FOR INFORMATION ONLY. THE INDICATED VALUE WAS USED FOR DESIGN CALCULATIONS TO DETERMINE AMPERE INTERRUPTING CURRENT (AIC) RATINGS. THE ACTUAL IMPEDANCE VALUE FOR THE UTILITY PROPOSED TRANSFORMER SHALL BE USED FOR FAULT
CURRENT, PROTECTIVE COORDINATION AND ARC FLASH STUDIES AND SUBSEQUENT RATING OF
EQUIPMENT.
9. MINIMUM INTERRUPTING CAPACITIES SHOWN ON PANEL SCHEDULES ARE BASED ON DESIGN FAULT CALCULATIONS USING THE FEEDER SIZES AND THE TRANSFORMER IMPEDANCE INDICATED ON THE POWER ONE-LINE DIAGRAM (THIS SHEET). THE FAULT CURRENT AND PROTECTIVE COORDINATION STUDY REQUIRED BY THE SPECIFICATIONS SHALL USE DATA FROM THE ACTUAL FEEDERS AND EQUIPMENT INSTALLED. BRACING AND INTERRUPTING RATINGS SHALL BE ADJUSTED TO MEET THE FAULT CURRENTS
DETERMINED BY THE FAULT CURRENT AND PROTECTIVE COORDINATION STUDY.
10. THE CONTRACTOR SHALL SUBMIT ARC FLASH CALCULATIONS BASED ON THE INSTALLED EQUIPMENT SIZES, RATINGS, AND SETTINGS. THE CALCULATIONS SHALL BE SUBMITTED AS PART OF THE FAULT
CURRENT AND PROTECTIVE DEVICE COORDINATION STUDY.
PANEL
LP2
100 A
PANEL
LP1
100 A
4#1, #6G, 2"C
4#1/0,#6G, 2"C
PANEL
CP
4#1, #6G, 2"C
26 HP 5 HP 5 HP .75 HP .75 HP
MOTOR 1 MOTOR 2 MOTOR 3 MOTOR 4 MOTOR 5
OVERHEAD CRANE
480Y/277V
3 PH, 4 WIRE
OVERHEAD CRANE
ENCLOSED CIRCUIT BREAKER
(ECB-03), NEMA 3R
100 AMPERE RATING
80 A, 10KA AIC
SERVICE ENTRANCE RATED
4#2, #6G, 1'-1/2"C, TO SINGLE POINT CONNECTION
IN ACCORDANCE WITH
MANUFACTURER
RECOMMENDATIONS
80 A
4#400, #1/0G, 3-1/2" C
CHILLER 1 CHILLER 2
450 A 450 A
4#400, #1/0G, 3-1/2" C
CHILLER-02
ENCLOSED CIRCUIT BREAKER
ECB-02, NEMA 3R
600 AMPERE RATING
450 A, 35KA AIC
SERVICE ENTRANCE RATED
CHILLER-01
ENCLOSED CIRCUIT BREAKER
ECB-01, NEMA 3R
600 AMPERE RATING
450 A, 35KA AIC
SERVICE ENTRANCE RATEDM-2
KEY NOTES:
1. CURRENT SENSOR WIRES SHALL BE
INSTALLED IN ENCLOSED BREAKER AND
METER SHALL BE INSTALLED IN ELECTRICAL
ROOM.
2. CURRENT SENSORS WIRES BETWEEN
ENCLOSED BREAKER AND ELECTRICAL
ROOM SHALL BE IN 1/2" CONDUIT.
CURRENT SENSOR WIRES SHALL BE IN
ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATION.
3.CURRENT SENSOR WIRES SHALL BE
INSTALLED IN THE POWER UTILITY
TRANSFORMER AND METER SHALL BE
INSTALLED IN ELECTRICAL ROOM.
1 1
2 2
M-1
M-9M-8 M-11
PANEL
RP1
PANEL
RP2
M-3
#2/0 GEC
#8
GEC
#1/0GEC
700 A
ENCLOSED CIRCUIT BREAKER
ECB-04, NEMA 3R
1200A AMPERE RATING
700 A CB, 35KA AIC
SERVICE ENTRANCE RATED
700 A
ENCLOSED CIRCUIT
BREAKER
ECB-05, NEMA 3R
1200A AMPERE RATING
700 A CB, 35KA AIC
GFGI
GEN
GROUNDING
ELECTRODE
#3/0
GEC
NE
L
1000 KVA PAD MOUNTED
TRANSFORMER WITH
PAD AND GROUNDING
(BY UTILITY)
12.4KV- 480Y/277V
3 PH, 4 WIRE
Z = 3.5%
+ 2.5 % TAP ON SECONDARY
UTILIT
Y
(2 SETS)
4#600, 1/0G 4"C
QCPP
800 A
M-1
M-6M-5M-4 M-7
GFGI (FOR INFORMATION ONLY)
(2 SETS)
4#600, 1/0 EQUIPMENT
GROUNDING CONDUCTOR OR
SUPPLY-SIDE BONDINGJUMPER,
4"C
NG
(2 SETS)
4#600, 1/0 EQUIPMENT
GROUNDING
CONDUCTOR, 4"C
(2 SETS)
4#600, 4"C
M-1
#1/0 GEC
#2 GEC
SERVICE ENTRANCES SHALL BE
IDENTIFIED IN ACCORDANCE
WITH NEC ARTICLE 230.
N N N
QUICK CONNECT
POWER PANEL. SEE
SPEC 26 20 00,
PARAGRAPH 2.16.
4#400, 3-1/2" C
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENDKRW\Documents\FY18PN80855_MEP_R18_K6ENDKRW.rvt
3/27/2018 6:32:24 AM
M
AR
C H
W
2H N
-1 8-
R -3
L.
R
O D
R
IG
U
EZ
L.
R
O D
R
IG
U
EZ
0-
EP601
PO
W
ER
R
IS
ER
D
IA
G R
AM
SA
VA
N N
AH
D
IS
TR
IC
T
Sa va nn ah
, G eo rg ia
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
TR
AI
N
IN
G
S U
PP
O
R T
FA
C
IL
IT
Y
PN
M . B
R
EN
N
AN
ISSUED FOR CONSTRUCTION
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
M
AR
1 8
| A-321 WALL DETAILS |
| A-510 WALL / PARTITION TYPES |
| A-603 DOOR DETAILS - EXTERIOR II |
| A-604 DOOR DETAILS - INTERIOR I |
| I-611 ROOM FINISH SCHEDULE, FINISH LEGEND, & DETAILS |
| EP601 POWER RISER DIAGRAM |
File details come from the government source that posted it.