W912HN-18-B-3003_VOL2.pdf
PDF 16 MB Posted
- Attached to
- Training Support Facility
- Solicitation number
- W912HN18R3003
About this file
W912HN-18-R-3003 DRAWINGS VOL2
View the file
Other files
| File | Type | Posted |
|---|---|---|
| amd3.pdf | ||
| 18R3003vol1.PDF | ||
| 18R3003vol3.PDF | ||
| W912HN-18-R-3003_VOL2_AMD2.pdf | ||
| 18R3003vol1.PDF | ||
| W912HN-18-R-3003_VOL1_AMD2.pdf | ||
| 18R3003vol2.PDF | ||
| amd2.pdf | ||
| amd1.pdf | ||
| W912HN-18-R-3003_VOL2_AMD1.pdf | ||
| 18R3003vol1.PDF | ||
| 18R3003vol2.PDF | ||
| 18R3003vol3.PDF | ||
| W912HN-18-R-3003_VOL1_AMD1.pdf | ||
| W912HN-18-B-3003_VOL1.pdf | ||
| 18R3003vol3.PDF | ||
| 18R3003vol1.PDF | ||
| 18R3003vol2.PDF |
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET ID. TITLE
INDEX OF DRAWINGS - VOLUME
TITLE TITLESHEET ID. SHEET ID.
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
E C
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
S I
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENDKRW\Documents\FY18PN80855_PROJ_R15_K6ENDKRW.rvt
3/1/2018 7:14:42 AM
M
AR
C H
W
2H N
-1 8-
R -3
XX
X
YY
Y
Au th or
XX
X
YY
Y
C
AT
C O
D E
G-002
IN
D
EX
O
F D
R A W
IN
G
S
SA
VA
N N
AH
D
IS
TR
IC
T
Sa va nn ah
, G e o rg ia
F O R
T
BE
N N
IN
G
, G
EO
R G
I A
TR
A I N
IN
G
S U
PP
O
R T
FA
C
IL
IT
Y P N
5 5
XX
X
YY
Y
ISSUED FOR CONSTRUCTION
E-001 LEGEND AND NOTES
E-002 ELECTRICAL GENERAL NOTES AND ABBREVIATIONS
EG101 LIGHTNING PROTECTION PLAN
EG102 LIGHTNING PROTECTION PLAN
EG501 LIGHTNING PROTECTION DETAILS
EG502 GROUNDING DETAILS
EL101 LIGHTING PLAN AREA A
EL102 LIGHTING PLAN AREA B
EL103 LIGHTING PLAN AREA C
EL104 LIGHTING PLAN AREA D
EL105 LIGHTING PLAN AREA E
EL501 LIGHT FIXTURE SCHEDULE AND DETAILS
EL601 LIGHTING CONTROL STRATEGY SCHEDULE AND DIAGRAMS
EL602 EMERGENCY LIGHTING INVERTER SCHEDULE(NO USED)
EP101 POWER PLAN AREA A
EP102 POWER PLAN AREA B
EP103 POWER PLAN AREA C
EP104 POWER PLAN AREA D
EP105 POWER PLAN AREA E
EP106 EQUIPMENT POWER PLAN AREA A
EP107 EQUIPMENT POWER PLAN AREA B
EP108 EQUIPMENT POWER PLAN AREA C
EP109 EQUIPMENT POWER PLAN AREA D
EP110 EQUIPMENT POWER PLAN AREA E
EP601 POWER RISER DIAGRAM
EP602 PANEL SCHEDULES
EP603 PANEL SCHEDULES
EP604 PANEL SCHEDULES
EP605 ELECTRICAL METERING DETAILS
EP606 MOTOR FEEDER SCHEDULE
EY101 SPECIAL SYSTEMS PLAN A
EY102 SPECIAL SYSTEMS PLAN B
EY103 SPECIAL SYSTEMS PLAN C
EY104 SPECIAL SYSTEMS PLAN D
EY105 SPECIAL SYSTEMS PLAN E
EY601 SPECIAL SYSTEMS RISER DIAGRAMS
EY602 SPECIAL SYSTEM SINGLE-LINE
T-001 COMMUNICATIONS LEGEND AND GENERAL NOTES
TN101 COMMUNICATIONS PLAN AREA E
TN501 COMMUNICATIONS DETAILS
TN601 COMMUNICATIONS DIAGRAMS
FA103 FIRE ALARM AND MNS FLOOR PLAN AREA C
FA104 FIRE ALARM AND MNS FLOOR PLAN AREA D
FA105 FIRE ALARM AND MNS FLOOR PLAN AREA E
FA601 FIRE ALARM AND MNS DIAGRAM
FX001 FIRE PROTECTION LEGEND AND GENERAL NOTES
FX100 FIRE PROTECTION FLOOR PLAN - COMPOSITE
FX101 FIRE PROTECTION FLOOR PLAN - PART A
FX102 FIRE PROTECTION FLOOR PLAN - PART B & C
FX103 FIRE PROTECTION FLOOR PLAN - PARTS D & E
FX501 FIRE PROTECTION DETAILS I
FX502 FIRE PROTECTION DETAILS II
FX503 FIRE PROTECTION DETAILS III
P-001 PLUMBING LEGEND
PL101 PLUMBING DOMESTIC WATER PLAN - PART A
PL102 PLUMBING DOMESTIC WATER PLAN - PART B
PL103 PLUMBING DOMESTIC WATER PLAN - PART C
PL104 PLUMBING DOMESTIC WATER PLAN - PART D
PL105 PLUMBING DOMESTIC WATER PLAN - PART E
PL111 PLUMBING SANITARY SEWER PLAN - PART E
PL121 PLUMBING NATURAL GAS PLAN - PART E
PL301 PLUMBING SECTIONS
PL401 PLUMBING ENLARGED PLANS I
PL402 PLUMBING ENLARGED PLANS II
PL501 PLUMBING DETAILS I
PL502 PLUMBING DETAILS II
PL503 PLUMBING DETAILS III
PL601 PLUMBING SCHEDULES
PL901 PLUMBING DOMESTIC WATER ISOMETRICS
PL902 PLUMBING SANITARY SEWER ISOMETRICS
M-001 HVAC LEGEND
MH101 HVAC DUCTWORK PLAN - PART A
MH102 HVAC DUCTWORK PLAN - PART B
MH103 HVAC DUCTWORK PLAN - PART C
MH104 HVAC DUCTWORK PLAN - PART D
MH105 HVAC DUCTWORK PLAN - PART E
MH111 HVAC THERMOSTAT, HUMIDISTAT & SENSOR PLAN - PART A
MH112 HVAC THERMOSTAT, HUMIDISTAT & SENSOR PLAN - PART B
MH113 HVAC THERMOSTAT, HUMIDISTAT & SENSOR PLAN - PART C
MH114 HVAC THERMOSTAT, HUMIDISTAT & SENSOR PLAN - PART D
MH115 HVAC THERMOSTAT, HUMIDISTAT & SENSOR PLAN - PART E
MH301 HVAC SECTIONS I
MH302 HVAC SECTIONS II
MH303 HVAC SECTIONS III
MH304 HVAC SECTIONS IV
MH305 HVAC SECTIONS V
MH401 HVAC ENLARGED DUCTWORK PLANS
MH402 HVAC ENLARGED HYDRONIC PIPING PLANS
MH403 HVAC ENLARGED MECH ROOM ROOF PLAN
MH501 HVAC DETAILS I
MH502 HVAC DETAILS II
MH503 HVAC DETAILS III
MH504 HVAC DETAILS IV
MH505 HVAC DETAILS V
MH506 HVAC DETAILS VI
MH601 HVAC SCHEDULES I
MH602 HVAC SCHEDULES II
MH701 HYDRONIC CHILLED WATER PIPING SCHEMATIC
MH702 HYDRONIC HOT WATER PIPING SCHEMATIC
MI001 HVAC CONTROLS LEGEND
MI002 HVAC CONTROLS GENERAL NOTES
MI003 HVAC CONTROLS SCHEDULING INSTRUCTIONS
MI801 AHU-01 & AHU-02 CONTROL SCHEMATIC
MI802 AHU-01 & AHU-02 CONTROL SEQUENCE OF OPERATION
MI803 AHU-01 & AHU-02 CONTROL SCHEDULES
MI804 AHU-01 & AHU-02 CONTROL POINTS SCHEDULE
MI805 DOAS-01 CONTROL SCHEMATIC
MI806 DOAS-01 CONTROL SEQUENCE OF OPERATION
MI807 DOAS-01 CONTROL SCHEDULES
MI808 DOAS-01 CONTROL POINTS SCHEDULE
MI809 MISCELLANEOUS CONTROL SCHEMATICS
MI810 MISCELLANEOUS SEQUENCES OF OPERATION
MI811 MISCELLANEOUS CONTROL POINTS SCHEDULES
MI812 MISCELLANEOUS CONTROL POINTS SCHEDULES
MI813 MISCELLANEOUS CONTROL POINTS SCHEDULES
MI814 MISCELLANEOUS CONTROL POINTS SCHEDULES
MI815 BOILER CONTROL SCHEMATIC AND SEQUENCE OF OPERATION
MI816 BOILER CONTROL POINTS SCHEDULE
MI817 CHILLER CONTROL SCHEMATIC AND SEQUENCE OF OPERATION
MI818 CHILLER CONTROL POINTS SCHEDULE
MI819 DOM. HOT WATER CONTROL SCHEMATIC, SEQUENCE OF OPERATION, & POINTS SCHEDULE
MI820 HUMIDIFIER CONTROL SCHEMATIC, SEQUENCE OF OPERATION & POINTS SCHEDULE
MP101 HVAC HYDRONIC PIPING PLAN - PART E
G-001 COVER SHEET
G-002 INDEX OF DRAWINGS
G-003 GENERAL NOTES, ABBREVIATIONS
S-001 GENERAL STRUCTURAL NOTES
S-002 GENERAL STRUCTURAL NOTES
SB101 FLOOR PLAN - COMPOSITE
SB102 FLOOR PLAN - PART A
SB103 FLOOR PLAN - PART B
SB104 FLOOR PLAN - PART C
SB105 FLOOR PLAN - PART D
SB106 FLOOR PLAN - PART E
SB501 FOUNDATION DETAILS
SB502 FOUNDATION DETAILS
SB601 FOUNDATION SCHEDULES
SF101 ROOF FRAMING PLAN - COMPOSITE
SF102 ROOF FRAMING PLAN - PART A
SF103 ROOF FRAMING PLAN - PART B
SF104 ROOF FRAMING PLAN - PART C
SF105 ROOF FRAMING PLAN - PART D
SF106 ROOF FRAMING PLAN - PART E
SF301 FRAMING SECTIONS
SF302 FRAMING SECTIONS
SF501 FRAMING DETAILS
SF502 FRAMING DETAILS
SF503 STRUCTURAL DETAILS
SF504 TYPICAL STRUCTURAL DETAILS
SF601 WALL SCHEDULES
A-101 COMPOSITE PLAN
A-101A DIMENSION PLAN
A-102 FLOOR PLAN - PART A
A-103 FLOOR PLAN - PART B
A-104 FLOOR PLAN - PART C
A-105 FLOOR PLAN - PART D
A-106 FLOOR PLAN - PART E
A-107 ROOF PLAN
A-108 REFLECTED CEILING PLAN
A-109 FLOOR FINISH PLAN
A-201 COMPOSITE ELEVATIONS
A-202 ENLARGED EXTERIOR ELEVATION - NORTH
A-203 ENLARGED EXTERIOR ELEVATION - SOUTH
A-301 BUILDING CROSS SECTION
A-302 BUILDING LONGITUDINAL SECTION
A-310 WALL SECTIONS
A-320 WALL DETAILS
A-321 WALL DETAILS
A-401 ENLARGED PLANS & INTERIOR ELEVATIONS
A-402 INTERIOR ELEVATIONS
A-500 ROOF DETAILS
A-501 ROOF DETAILS - SKYLIGHT
A-510 WALL / PARTITION TYPES
A-511 PARTITION TYPE NOTES / DETAILS
A-520 INTERIOR DETAILS
A-521 PLAN DETAILS
A-529 CEILING DETAILS SEISMIC
A-530 MISC. DETAILS
A-600 ROOM FINISH SCHEDULE
A-601 DOOR SCHEDULE AND LEGEND
A-602 DOOR DETAILS - EXTERIOR I
A-603 DOOR DETAILS - EXTERIOR II
A-604 DOOR DETAILS - INTERIOR I
A-605 DOOR DETAILS - INTERIOR II
A-606 WINDOW & LOUVER TYPES
A-607 WINDOW & LOUVER DETAILS
A-701 LIFE SAFETY PLAN
A-702 LIFE SAFETY DETAILS I
A-703 LIFE SAFETY DETAILS II
A-704 LIFE SAFETY DETAILS III
A-705 LIFE SAFETY DETAILS IV
A-706 LIFE SAFETY DETAILS V
A-800 AIR BARRIER PLAN AND NOTES
A-801 AIR BARRIER BLDG SECTIONS
A-802 AIR BARRIER BLDG SECTIONS II
A-803 AIR BARRIER SECTIONS
A-804 AIR BARRIER DETAILS I
A-810 AIR BARRIER SF CALCS
I-111 FURNITURE PLAN
I-501 SIGNAGE TYPICALS
I-611 ROOM FINISH SCHEDULE, FINISH LEGEND, & DETAILS
I-621 SIGNAGE SCHEDULE & DETAILS
FA001 FIRE ALARM LEGEND AND OPERATIONS MATRIX
FA101 FIRE ALARM AND MNS FLOOR PLAN AREA A
FA102 FIRE ALARM AND MNS FLOOR PLAN AREA B
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
SHEET LOGICMATERIALS
EARTH
DRAWING ABBREVIATIONS GENERAL NOTES
C (cont) ---------------------
COMM COMMUNICATION
CONC CONCRETE
CONC FLR CONCRETE FLOOR
CONF CONFERENCE
CONT CONTINUE, CONTINUOUS
COORD COORDINATE
CORR CORRIDOR
CP CONCRETE PIPE
CPT CARPET
CR CONTROL ROOM
CS CAST STONE
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTR CENTER
CU FT CUBIC FEET
CW CASEMENT WINDOW
D ---------------------
D DEPTH
D LABEL CLASS D DOOR
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
E ---------------------
E LABEL CLASS E DOOR
EA EACH
EF EACH FACE
EIFS EXTERIOR INSULATION
AND FINISH SYSTEM
EJ EXPANSION JOINT
ES EACH SIDE
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
ENTR ENTRANCE
EPS EXPANDED POLYSTYRENE
EQ EQUAL
EWC ELECTRIC WATER COOLER
EXP EXPOSED, EXPANSION
EXT EXTERIOR, EXTINGUISHER
EXT GR EXTERIOR GRADE
F ---------------------
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR
PANEL
FAS BD FASCIA BOARD
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER
CABINET
FED FEDERAL
FF FINISH FLOOR
FFE FINISH FLOOR ELEVATION
FF INSUL FOIL BACKED INSULATION
FGL FIBERGLASS
FH FIRE HOSE
FHP FULL HEIGHT PARTITION
FIN FINISH
FIN BS FINISH BOTH SIDES
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLMT FLUSH MOUNT
FLR FLOOR
FM FACTORY MUTUAL
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FR FIRE RESISTANT
FRG FIBER REINFORCED
GYPSUM
FRMG FRAMING
FRP FIBERGLASS REINFORCED
PLASTIC
FRTW FIRE RETARDANT
TREATED WOOD
FS FEDERAL SPECIFICATION
FSTNR FASTENER
FT FEET
FTG FOOTING
FWC FABRIC WALLCOVERING
G ---------------------
G NATURAL GAS
GALV GALVANIZED
GB GRAB BAR
GEJ GUTTER EXPANSION JOINT
GFCI GOVERNMENT FURNISHED
CONTRACTOR INSTALLED
GFGI GOVERNMENT FURNISHED
GOVERNMENT INSTALLED
GFRG GLASS-FIBER-
REINFORCED GYPSUM
GLZ GLAZING
GR FL GROUND FLOOR
GUT GUTTER
GWB GYPSUM WALL BOARD
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
H -------------
HB HOSE BIBB
HC HANDICAPPED
HDPE HIGH DENSITY
POLYETHYLENE
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY
PARTICULATE AIR (FILTER)
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HORIZ HORIZONTAL
HR HOUR
HT HEIGHT
HYDR HYDRAULIC
I ---------------------
IBC INTERNATIONAL BUILDING
CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
J ---------------------
JAN JANITOR
JT JOINT
K ---------------------
KPD KEYPAD
KIT KITCHEN
KPL KICKPLATE
L ---------------------
LAM LAMINATE
LAV LAVATORY
LBR LUMBER
LBS POUND
LDG LANDING
LF LINEAR FEET (FOOT)
LG LIGHT GAUGE
LIB LIBRARY
LIN LINEAR
LKR LOCKER
LOC LOCATION
LT LIGHT
LVDR LOUVER DOOR
LVR LOUVER
M ---------------------
MACH RM MACHINE ROOM
MATL MATERIAL
MAX MAXIMUM
MC MOISTURE CONTENT
MD METAL DECK
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MEMB MEMBRANE
MF MILL FINISH
MFR MANUFACTURER
MID MIDDLE
MIN MINIMUM, MINUTE
MIRR MIRROR
MISC MISCELLANEOUS
MLDG MOLDING (MOULDING)
MO MASONRY OPENING
MOD MODIFY
MB MOISTURE BARRIER
MTD MOUNTED
MTG MOUNTING
MTL METAL
MVBL MOVABLE
MWP MEMBRANE
WATERPROOFING
N ---------------------
N NORTH
NA NOT APPLICABLE
NFPA NATIONAL FIRE
PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NP NO PAINT
NRC NOISE REDUCTION
COEFFICIENT
NTS NOT TO SCALE
O -------------------
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFD OVERFLOW DRAIN
OFF OFFICE
OGL OBSCURE GLASS
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPQ OPAQUE
OWSJ OPEN WEB STEEL JOIST
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
P --------------------
PA PUBLIC ADDRESS
PAR PARAPET
PAT PATTERN
PB PULL BOX
PBD PARTICLEBOARD
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PCT PERCENT
PERF PERFORATED
PERIM PERIMETER
PH PHASE
PIL PILASTER
PL PROPERTY LINE
PL GL PLATE GLASS
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PLG PILING
PLYWD PLYWOOD
PNL PANEL
PP PL PUSH/PULL PLATE
PR PAIR
PRCST PRECAST
PREFIN PREFINISHED
PRKG PARKING
PS CONC PRESTRESSED CONCRETE
PSF POUNDS PER SQUARE
FOOT
PSI POUNDS PER SQUARE
INCH
PT PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTDR PAPER TOWEL DISPENSER
AND RECEPTACLE
PTN PARTITION
PWR POWER
Q --------------------
QT QUARRY TILE
QTY QUANTITY
R --------------------
RB RESILIENT BASE
RBM REINFORCED BRICK
MASONRY
RBR RUBBER
RC REINFORCED CONCRETE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RDG INS RIGID INSULATION, SOLID
REC RECESSED
REF REFERENCE
REM REMOVABLE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
REST RESTROOM
RF RESILIENT FLOORING
RFG ROOFING
RH ROOF HATCH
RHR RIGHT HAND REVERSE
RL ROOF LEADER
RLG RAILING
RM ROOM
R (cont) --------------------
RO ROUGH OPENING
RSD ROLLING STEEL DOOR
RV ROOF VENT
RVL REVEAL
S --------------------
SB SPLASH BLOCK
SCHED SCHEDULE
SD SMOKE DETECTOR
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SGL SINGLE
SHT MTL SHEET METAL
FLASH (FLASHING)
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SKLT SKYLIGHT
SLNT SEALANT
SMK SMOKE
SMLS SEAMLESS
SP EL SPOT ELEVATION
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SS STAINLESS STEEL
SSMR STANDING SEAM METAL ROOF
ST STAIRS
STC SOUND TRANSMISSION
COEFFICIENT
STD STANDARD
STL STEEL
STL JST STEEL JOIST
STL RF DK STEEL ROOF DECK
STOR STORAGE
STR STRINGERS
STRB/HRN STROBE/HORN
STRUC STRUCTURAL
SUB FL SUBFLOOR
SUSP SUSPENDED
SV SHEET VINYL
SW SIDEWALK
T --------------------
T TREAD
T/S TUB/SHOWER
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZZO
TFF TOP OF FINISH FLOOR
TH THICK
THK THICKNESS
TK BD TACKBOARD
TMPD GL TEMPERED GLASS
TN TRUE NORTH
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOPO TOPOGRAPHY
TOS TOP OF SLAB
TRANS TRANSOM
TRTD TREATED
TV TELEVISION
TYP TYPICAL
U --------------------
UG UNDERGROUND
UH UNIT HEATER
UL UNDERWRITER
LABORATORIES
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER
SYSTEM
V --------------------
VAV VARIABLE AIR VOLUME/UNIT
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VTR VENT THRU ROOF
W --------------------
W/ WITH
WC WATER CLOSET
WD WOOD
WDW WINDOW
W/O WITHOUT
WWF WELDED WIRE FABRIC
X --------------------
XFMR TRANSFORMER
A ---------------------
A LABEL CLASS A DOOR
A/C AIR CONDITION
A/C UNIT AIR CONDITIONING UNIT
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
ABV ABOVE
ACC ACCESSIBLE
ACS AUTOMATIC CONTROL
SYSTEM
ACS DR ACCESS DOOR
ACS PNL ACCESS PANEL
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH
DISABILITIES ACT
ADJ ADJACENT
ADMIN ADMINISTRATION
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGGR AGGREGATE
AHU AIR HANDLING UNIT
AIB AIR INFILTRATION BARRIER
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZE
APPROX APPROXIMATE
AR AS REQUIRED
ARCH ARCHITECT
ASC ABOVE SUSPENDED
CEILING
ASSY ASSEMBLY
ATC ACOUSTICAL TILE CEILING
AVG AVERAGE
AWT ACOUSTICAL WALL
TREATMENT
B ---------------------
B LABEL CLASS B DOOR
BALC BALCONY
BD BOARD
BDRY BOUNDARY
BEJ BRICK EXPANSION JOINT
BFF BELOW FINISH FLOOR
BHMA BUILDER'S HARDWARE
MANUFACTURER'S
ASSOCIATION
BLDG BUILDING
BLKG BLOCKING
BLT IN BUILT-IN
BN BULLNOSE
BOS BOTTOM OF STEEL
BOT BOTTOM
BRG BEARING
BRKT BRACKET
BSMT BASEMENT
BTWN BETWEEN
BUR BUILT-UP ROOFING
C ---------------------
C LABEL CLASS C DOOR
CAB CABINET
CATW CATWALK
CAV CAVITY
CBB CEMENTITIOUS (BACKER)
BOARD
CD CONSTRUCTION
DOCUMENTS
CDW CHILLED DRINKING WATER
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CFCI CONTRACTOR
FURNISHED/CONTRACTOR
INSTALLED
CFE CONTRACTOR FURNISHED
EQUIPMENT
CFM CUBIC FEET PER MINUTE
CFMF COLD-FORMED METAL
FRAMING
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CI CAST IRON
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG DIFF CEILING DIFFUSER
CLG HT CEILING HEIGHT
CLL COLUMN LINE
CLO CLOSET
CLR COLOR
CMU CONCRETE MASONRY UNIT
CNDS CONDENSATE
CDR CARD READER
CO CLEANOUT
COL COLUMN
0 GRID/COLUMN
LINE
DESIGNATOR
INTERIOR ELEVATION
SECTION
ROOM
NAME/NUMBER
REVISION
TAG
PLAN, BLOW-UP DETAIL
PLAN NORTH
NORTH ARROW
w/ TRUE NORTH
INDICATION
SPOT ELEVATION
Name Elevation REFERENCE LEVEL
PLATE NUMBER WHERE
SECTION/DETAIL IS DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS DRAWN
A-101
SIM
A-101
Ref
R ef
R ef
Ref
A101
Ref
R ef
Ref
R ef
EXTERIOR ELEVATION
PLATE NUMBER WHERE
SECTION/DETAIL IS DRAWN
A-101
SYMBOLS
INTERIOR ELEVATION SYMBOL
EXTERIOR ELEVATION SYMBOL
SECTION SYMBOL
CALLOUT SYMBOL
ELEVATION SYMBOL
LEVEL SYMBOL
GENERAL SYMBOLS
Room name
Room name
150 SF
ROOM
NAME/NUMBER
W/ AREA
CENTERLINE
INDICATOR
1/2 1 21
SCALE: 1"=1'-0"
SCALE BAR
1 View Name 1/8" = 1'-0"R101
MATCHLINE INDICATOR
VIEW TITLE BAR
1 / A-101
1 / A-102
REFERENCE SHEETS
SAND
CONCRETE/ PRECAST
CONCRETE
STONE
BRICK
CMU
PLYWOOD
RIGID INSULATION
BATT INSULATION
GYPSUM BOARD,
PLASTER
EIFS
1. THESE LEGENDS ARE COMPOSED OF STANDARD SYMBOLS AND ARE PERTINENT TO THE CONDITIONS
ON THIS SET OF DRAWINGS TO THE EXTENT APPLICABLE.
2. ADDITIONAL LEGENDS AND/OR ABBREVIATIONS MAY APPEAR IN THIS SET OF DRAWINGS TO INDICATE
SPECIFIC CONDITIONS IN LIEU OF SYMBOLS SHOWN ON THIS SHEET.
AE201
DISCIPLINE*:
G - GENERAL
C - CIVIL
L - LANDSCAPE
S - STRUCTURAL
A - ARCHITECTURE
DISCIPLINE DESIGNATOR
SHEET TYPE DESIGNATOR
SHEET SEQUENCE
NUMBER
F- FIRE PROTECTION
P - PLUMBING
M - MECHANICAL
E - ELECTRICAL
T- TELECOMMUNICATIONS
*ADDITIONAL DISCIPLINES MAY BE USED
IN THIS DRAWING SET.
DRAWING NAMING CONVENTION
SHEET ID
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
E C
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
S I
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENDKRW\Documents\FY18PN80855_PROJ_R15_K6ENDKRW.rvt
3/1/2018 7:14:48 AM
M
AR
C H
W
2H N
-1 8-
R -3
XX
X
YY
Y
Au th or
XX
X
YY
Y
C
AT
C O
D E
G-003
G
EN
ER
AL
N O
T E S, A B B
R
EV
IA
TI
O N
S
SA
VA
N N
AH
D
IS
TR
IC
T
Sa va nn ah
, G e o rg ia
F O R
T
BE
N N
IN
G
, G
EO
R G
I A
TR
A I N
IN
G
S U
PP
O
R T
FA
C
IL
IT
Y P N
5 5
XX
X
YY
Y
ISSUED FOR CONSTRUCTION
M
AR
K D
ES
C
R
IP
TI
O
N D
GENERAL NOTES:
G-1. USE STRUCTURAL DRAWINGS IN CONJUNCTION WITH ALL OTHER DRAWINGS. COORDINATE THE WORK OF OTHER TRADES INCLUDING, BUT NOT LIMITED TO, THE REQUIREMENTS FOR SLEEVES, INSERTS, HOLES, HANGERS, AND ANCHORS.
G-2. REPORT DISCREPANCIES IN DIMENSIONS BETWEEN DIFFERENT DRAWINGS TO CONTRACTING
OFFICER PRIOR TO BEGINNING WORK IN AREAS THAT WILL BE AFFECTED.
G-3. DETAILS TITLED OR NOTED AS "TYPICAL" APPLY NOT ONLY WHERE SPECIFICALLY INDICATED OR
REFERENCED, BUT ALSO IN ALL OTHER CASES WHERE THE NATURE OF THE CONSTRUCTION
REQUIRES THEIR USE. DETERMINE APPLICABILITY OF TYPICAL DETAILS FROM DESCRIPTIVE TITLES OR FROM THE SIMILARITY OF A CONSTRUCTION CONDITION TO ANOTHER CONDITION WHERE THE
DETAIL IS SPECIFICALLY INDICATED OR REFERENCED.
G-4. PROVIDE TEMPORARY BRACING AND SHORING OF THE STRUCTURE AND COMPONENTS UNTIL ALL COMPONENTS ARE ERECTED AND ALL CONNECTIONS ARE FULLY MADE, AS NECESSARY, TO ENSURE
STABILITY DURING CONSTRUCTION. BRACE ALL WALLS DURING CONSTRUCTION AGAINST WIND
AND/OR CONSTRUCTION LOADS.
G-5. ELEVATIONS ON THE STRUCTURAL DRAWINGS ARE DENOTED AS [±X'-X"] REFERENCED TO THE FINISHED FIRST FLOOR ELEVATION DATUM [0'-0"]. SEE CIVIL DRAWINGS FOR ACTUAL DATUM
ELEVATION.
G-6. REPRODUCTION OF CONTRACT DRAWINGS SHALL NOT BE USED AS SHOP DRAWINGS UNDER ANY
CIRCUMSTANCE.
FOUNDATION AND SLAB NOTES:
F-1. FOUNDATIONS FOR THIS PROJECT HAVE BEEN DESIGNED IN ACCORDANCE WITH THE
RECOMMENDATIONS IN THE GEOTECHNICAL REPORT PREPARED BY THE SAVANNAH DISTRICT TITLED "SUBSURFACE EXPLORATION AND GEOTECHNICAL ENGINEERING REPORT, TRAINING SUPPORT FACILITY, FY 18, LI 80885, FT BENNING, GA", DATED *JUNE* 2017.
F-2. FOUNDATIONS HAVE BEEN DESIGNED TO BEAR ON SOIL CAPABLE OF SUPPORTING AN ALLOWABLE BEARING PRESSURE OF 3000 PSF AS STATED IN THE GEOTECHNICAL REPORT REFERENCED ABOVE.
F-3. THE CONTRACTOR SHALL HIRE AN INDEPENDENT TESTING LABORATORY AND GEOTECHNICAL ENGINEER, REGISTERED AND LICENSED IN THE STATE WHERETHE WORK WILL BE ACCOMPLISHED, TO VERIFY THAT ALL OF THE REQUIREMENTS CONTAINED IN SPECIFICATION 31 00 00, EARTHWORK, HAVE BEEN FOLLOWED AND ACCOMPLISHED.
F-4. ALL EXCAVATIONS SHALL BE PERFORMED SO THAT THE SITE AND THE AREA IMMEDIATELY SURROUNDING THE SITE WHICH AFFECTS CONSTRUCTION OPERATIONS WILL BE CONTINUALLY AND
EFFECTIVELY DRAINED. THE CONTRACTOR SHALL PROVIDE DRAINAGE AND DEWATERING AS
REQUIRED TO ENSURE THAT ALL FOOTING EXCAVATIONS ARE ACCOMPLISHED WITH THE SUBGRADE SOILS REMAINING DRY AND FIRM UNTIL AFTER FOOTINGS ARE PLACED AND BACKFILLED. REMOVAL
OF SURFACE WATER, GROUNDWATER, AND ANY PERCHED WATER CONDITIONS WHICH MIGHT BE
ENCOUNTERED DURING EXCAVATIONS, SHALL BE ACCOMPLISHED BY APPROVED MEANS. REFER TO SPECIFICATION SECTION 31 00 00, EARTHWORK, AND TO SHEET B-301 FOR ADDITIONAL EXCAVATION
REQUIREMENTS.
F-5. DO NOT PLACE FOUNDATION CONCRETE ON FROZEN OR SATURATED SUBGRADES.
F-6. ENSURE THAT EARTH-FORMED FOOTINGS CONFORM TO THE SHAPE, LINES, AND THICKNESSES INDICATED ON THE FOUNDATION PLAN, SECTIONS, AND FOOTING SCHEDULES. EXCAVATION WIDTHS
SHALL BE A MINIMUM OF 4" GREATER THAN DIMENSIONS INDICATED.
F-7. DO NOT INSTALL FOUNDATIONS UNTIL FOUNDATION WORK HAS BEEN COORDINATED WITH WITH IN
STALLATION OF ADJACENT UNDERGROUND UTILITIES.
F-8. PLACE 10 MIL VAPOR RETARDER ON 4" CAPILLARY WATER BARRIER UNDER ALL INTERIOR
SLABS-ON-GRADE (TYPICAL).
CONCRETE CONSTRUCTION NOTES:
C-1. ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE PROVISIONS OF THE "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" (ACI 318-14) AND THE SPECIFICATIONS FOR
STRUCTURAL CONCRETE (ACI 301-16) OF THE AMERICAN CONCRETE INSTITUTE (ACI).
C-2. ALL CAST-IN-PLACE CONCRETE SHALL ATTAIN MINIMUM 28-DAY COMPRESSIVE STRENGTH (f'c) OF 4000 PSI AND UTILIZE MAXIMUM WATER-CEMENTITIOUS MATERIAL RATIO (w/cm) OF 0.50.
C-3. CONCRETE DENSITY SHALL BE NORMAL WEIGHT WITH A DENSITY OF 140 PCF TO 150 PCF UNLESS NOTED
OTHERWISE ON PLANS.
C-4. CONCRETE REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO ASTM A615/A615M, GRADE 60 AND SHALL HAVE FABRICATION TOLERANCES IN ACCORDANCE WITH ACI 315. SHOP
FABRICATE REINFORCING BARS WHICH ARE INDICATED TO BE BENT OR HOOKED.
C-5. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 OR ASTM A497. PROVIDE SHEET-TYPE WELDED
WIRE FABRIC. SHEET LAPS SHALL BE TIED AND LAPPED ONE FULL MESH SPACING PLUS 2".
C-6. CONCRETE REINFORCING STEEL SHALL BE CONTINUOUS UNLESS OTHERWISE INDICATED.
CONTINUOUS REINFORCING STEEL SHALL BE SPLICED AS SHOWN IN SCHEDULE. REINFORCING STEEL
SHALL BE PLACED SO THAT SPACING IS GREATER THAN OR EQUAL TO 2X BAR DIAMETER.
C-7. MINIMUM CONCRETE COVER FOR REINFORCING STEEL SHALL BE AS INDICATED. IN NO CASE SHALL
REINFORCEMENT COVER BE LESS THAN THE REQUIREMENTS OF ACI 301.
A. CONCRETE DEPOSITED AGAINST THE GROUND 3"
B. CONCRETE EXPOSED TO EARTH OR WEATHER 2"
C. SLABS AND WALLS 1"
C-8. CONCRETE REINFORCING STEEL MARKED STANDARD HOOK SHALL HAVE A 90° HOOK A MINIMUM OF 12 BAR DIAMETERS IN LENGTH, UNLESS OTHERWISE NOTED. STIRRUPS, TIES, AND 180° HOOKS SHALL
CONFORM TO THE REQUIREMENTS OF ACI 318.
C-9. PROVIDE 1/2" THICK PRE-MOLDED JOINT FILLER MATERIAL WHERE SLABS ON GRADE ABUT VERTICAL
SURFACES.
C-10. ALL EMBEDDED ITEMS SHALL BE PROPERLY PLACED, ACCURATELY POSITIONED AND MAINTAINED SECURELY
IN PLACE PRIOR TO AND DURING CONCRETE PLACEMENT.
C-11. REINFORCING STEEL SHALL BE SPREAD AT SLEEVES, ANCHORS, RECESSES AND OTHER EMBEDDED
ITEMS UNLESS OTHERWISE INDICATED. REINFORCEMENT SHALL NOT BE CUT TO FACILITATE
PLACEMENT OF EMBEDDED ITEMS, UNLESS INDICATED.
C-12. NO CONCRETE SHALL BE PLACED UNTIL THE OWNER OR THE CONTRACTING OFFICER'S DESIGNATED
REPRESENTATIVE HAS INSPECTED ALL EMBEDDED WORK, INCLUDING REINFORCEMENT.
C-13. ALL EXPOSED CONCRETE EDGES SHALL BE CHAMFERED 3/4" OR AS INDICATED.
C-14. ALUMINUM SHALL NOT BE PLACED IN DIRECT CONTACT WITH CONCRETE UNLESS EFFECTIVELY COATED
OR COVERED TO PREVENT ALUMINUM-CONCRETE REACTION AND ELECTROLYTIC ACTION BETWEEN
ALUMINUM AND STEEL.
C-15. CONCRETE SLAB ON GRADE JOINTS INDICATED ARE DIAGRAMMATIC AND DO NOT REPRESENT ALL OF THE JOINTS REQUIRED FOR SLAB-ON-GRADE CONSTRUCTION. SLAB PANELS BETWEEN JOINTS SHALL BE SQUARE OR NEARLY SO AND SHALL NOT EXCEED AN ASPECT RATIO WITH PANEL LENGTH GREATER
THAN 1.5 TIMES THE PANEL WIDTH.
C-16. CONTRACTOR SHALL PROVIDE JOINTS AT ALL RE-ENTRANT CORNERS INCLUDING, BUT NOT LIMITED
TO, COLUMNS AND SLAB RECESSES.
C-17. IN ADDITION, CONTRACTOR SHALL COORDINATE SLAB ON GRADE JOINT REQUIREMENTS WITH SLAB-
ON-GRADE CONSTRUCTION SEQUENCING. CONTRACTOR SHALL SHOW JOINT LAYOUT ON
REINFORCING SHOP DRAWING SUBMITTAL FOR APPROVAL.
C-18 CONTRACTOR SHALL APPLY CHEMICAL HARDENER TO CONCRETE TO INCREASE ITS DURIBILITY. SEE SPEC
SECTION 03 30 00 FOR HARDENER REQUIRMENTS.
DESIGN CODE NOTES:
D-1. STRUCTURAL DESIGN IS IN ACCORDANCE WITH THE FOLLOWING CODES AND
SPECIFICATIONS:
A. IBC 2015, INTERNATIONAL BUILDING CODE
B. ASCE 7-10, MINIMUM DESIGN LOADS FOR BUILDINGS AND STRUCTURES
C. ACI 318-14, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE
D. AISI S100-12, NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD
FORMED STEEL STRUCTURAL MEMBERS
E. UFC 1-200-01, GENERAL BUILDING REQUIREMENTS, (20 JUNE 2016)
F. UFC 3-301-01, STRUCTURAL ENGINEERING, (12 SEPTEMBER 2016)
G. UFC 3-310-04, SEISMIC DESIGN OF BUILDINGS, (20 JUNE 2016)
H. UFC 4-010-01, DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS,
(1 OCTOBER 2013)
DESIGN LOAD CRITERIA:
D-2. FIRST FLOOR LIVE LOADS:
FIRST FLOOR SLAB ON GRADE U.N.O. ACTUAL VEH. WEIGHT
MECHANICAL/ELECTRICAL ROOMS 150 PSF
STORAGE ROOMS 125 PSF
D-3. ROOF LIVE LOAD: 20 PSF (REDUCIBLE)
D-4. SNOW LOADS:
RISK CATEGORY II
SNOW IMPORTANCE FACTOR, Is 1.0 MINIMUM GROUND SNOW LOAD, Pg 5 PSF SNOW EXPOSURE FACTOR, Ce 0.9 SNOW THERMAL FACTOR, Ct 1.0 ROOF SLOPE FACTOR, Cs 1.0 FLAT ROOF SNOW LOAD, Pf=Pm 5 PSF SLOPED ROOF SNOW LOAD, Ps 5 PSF
D-5. WIND LOADS:
RISK CATEGORY II
WIND IMPORTANCE FACTOR, Iw 1.0
BASIC WIND SPEED, V 119 MPH
WIND EXPOSURE CATEGORY C
GUST EFFECT FACTOR, G 0.85
INTERNAL PRESSURE COEFFICIENTS, GCpi +/- 0.18
D-6. SEISMIC LOADS:
RISK CATEGORY II
SEISMIC IMPORTANCE FACTOR, Ie 1.0 MAPPED SPECTRAL RESPONSE ACCELERATION, Ss 0.12
MAPPED SPECTRAL RESPONSE ACCELERATION, S1 0.07
SITE CLASS D
DESIGN SPECTRAL RESPONSE ACCELERATION, Sds 0.13 DESIGN SPECTRAL RESPONSE ACCELERATION, Sd1 0.114
SEISMIC DESIGN CATEGORY B
SEISMIC ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE
SEISMIC-FORCE RESISTING SYSTEM MOMENT FRAME (MOM-FRAME)
ECCENTRICALLY BRACED FRAME
(BR-FRAME)
RESPONSE MODIFICATION FACTOR, R
- MOM-FRAME 3 1/2
- BR-FRAME 3 1/4
SYSTEM OVERSTRENGTH FACTOR
- MOM-FRAME 3
- BR-FRAME 2
DEFLECTION AMPLIFICATION FACTOR, Cd
- MOM-FRAME 3
- BR-FRAME 3 1/4
SEISMIC RESPONSE COEFFICIENT, Cs
- MOM-FRAME 0.037
- BR-FRAME 0.04
D-7. ANTI-TERRORISM/FORCE PROTECTION CRITERIA:
NEW BUILDING LOCATION PARKING AND ROADWAYS WITHIN
A CONTROLLED PERIMETER
BUILDING CATEGORY LOW OCCUPANCY BUILDING
DESIGN LEVEL OF THREAT LOW
DESIGN LEVEL OF PROTECTION (LOP) EXEMPT
PRE-ENGINEERED METAL BUILDING:
MB-1. THE PRE-ENGINEERED METAL BUILDING (PEMB) SYSTEM HAS BEEN PLANNED TO CONSIST OF
A RIGID FRAME STRUCTURE RESISTING GRAVITY AND LATERAL LOADS IN THE SHORT
DIRECTION AND X-BRACING RESISTING LATERAL LOADS IN THE LONG DIRECTION. THE
LATERAL FORCE RESISTING SYSTEM AND ALL LATERAL BRACING SHALL BE DESIGNED BY
THE PEMB MANUFACTURER. DESIGN BUILDING SYSTEM(S) IN ACCORDANCE WITH LATEST
EDITIONS OF IBC, ASCE, AISC, AND THE MBMA METAL BUILDING SYSTEMS MANUAL AND
SPECIFICATION SECTION 13 34 19.
MB-2. DESIGN BUILDING SYSTEM FOR LIVE LOADS INDICATED AND A COLLATERAL DEAD LOAD OF
7 PSF IN ADDITION TO BUILDING DEAD LOADS, WIND LOADS AND SEISMIC LOADS.
PARAMETERS FOR DEVELOPMENT OF WIND AND SEISMIC LOADS ARE LISTED IN THE
GENERAL NOTES. INCLUDE THE EFFECTS OF WINDWARD AND LEEWARD WIND PRESSURE
AND SUCTION LOADS.
MB-3. LOAD COMBINATIONS SHALL BE IN ACCORDANCE WITH LATEST EDITION OF IBC UNLESS THE
MBMA METAL BUILDING SYSTEMS MANUAL (LATEST EDITION) LOAD COMBINATIONS ARE MORE
STRINGENT.
MB-4. LIMIT THE STORY DRIFT OF THE STRUCTURE IN BOTH DIRECTIONS TO H/400.
MB-5. THE METAL ROOF DECK SHALL BE UTILIZED TO ACT AS A DIAPHRAGM TO TRANSFER THE
LATERAL LOADS. ROOF DIAGONAL BRACING SHALL BE PROVIDED IF THE METAL ROOF DECK
TO RESIST THE ROOF DIAPHRAGM SHEAR IS OMITTED OR ROOF PURLINS ARE INSUFFICIENT
TO TRANSFER DIAPHRAGM FORCES FROM THE METAL ROOF DECK TO THE PEMB FRAMES.
MB-6. REDUNDANCY SHALL BE PROVIDED TO THE VERTICAL AND HORIZONTAL BRACING SYSTEMS
BY USING MULTIPLE BAYS OF LATERAL MEMBERS.
MB-7. PIERS AND FOUNDATIONS SHOWN FOR THE BUILDING ARE FOR PRICING ESTIMATES ONLY.
THE CONTRACTOR SHALL HIRE A PROFESSIONAL ENGINEER TO REDESIGN THE METAL
BUILDING FOUNDATIONS FOR ACTUAL BUILDING LOADS PROVIDED BY THE METAL BUILDING
MANUFACTURER WHEN THE MAXIMUM REACTIONS DIFFER FROM THE ASSUMED COLUMN
REACTIONS SHOWN ON SHEET SB601. THE DESIGN SHALL BE BASED ON THE SOIL
PARAMETERS SPECIFIED IN NOTE F-1 ON THIS SHEET AND THE FINAL COLUMN REACTIONS
REPORTED BY THE PEMB MANUFACTURER. THE FINAL FOUNDATION DESIGN SHALL BE
SIGNED AND SEALED BY A PROFESSIONAL ENGINEER AND SHALL BE SUBMITTED TO THE
CONTRACTING OFFICER FOR APPROVAL. FOUNDATIONS FOR ELEMENTS OTHER THAN PEMB
COLUMN FOUNDATIONS WILL BE CONSTRUCTED AS SHOWN. SEE PLAN FOR LOCATIONS.
MB-8. THE CONTRACTOR SHALL COORDINATE THE COLUMN ANCHOR BOLT LAYOUT WITH THE PEMB
MANUFACTURER. AT LEAST FOUR (4) ANCHOR BOLTS ARE REQUIRED FOR COLUMN BASE
PLATES UNO. ANCHOR BOLTS SHALL NOT BE LESS THAN 3/4" NOMINAL SIZE. ANCHOR BOLTS
SHALL BE DESIGNED BY THE PEMB SUPPLIER. COLUMN ANCHOR BOLTS SHALL BE
POSITIVELY LOCATED USING 1/8" SHEET METAL TEMPLATES FOR ALL COLUMN BASE PLATES.
BASE PLATE TEMPLATE ANCHOR BOLT HOLES SHALL NOT EXCEED BOLT DIA. +/- 1/6”.
PROVISION SHALL BE MADE FOR ALL ANCHOR BOLTS TO BE RIGIDLY HELD IN POSITION TO
PREVENT MOVEMENT DURING CONCRETE PLACEMENT. ANCHOR BOLTS SHALL NOT BE
TIGHTENED PRIOR TO 14 DAYS FOLLOWING CONCRETE PLACEMENT.
MB-9. THE CONTRACTOR SHALL DESIGN, PROVIDE, AND COORDINATE STRUCTURAL FRAMING
MEMBERS FOR THE SUPPORT OF ALL HVAC UNITS, DUCTS, FANS, PIPING, ELECTRICAL
COMPONENTS, OPERABLE PARTITIONS, ETC.
MB-10. THE PEMB MANUFACTURER IS RESPONSIBILE FOR PROVIDING ADDITIONAL STRUCTURAL
MEMBERS AND CONNECTIONS TO BUILDING SUB-FRAMING AS NECESSARY AROUND
WINDOW AND SKYLIGHT OPENINGS SUCH THAT FRAME ATTACHMENTS MEET
ANTITERRORISM/FORCE PROTECTION CRITERIA PER UFC 4-010-01.
DOOR/WINDOW/SKYLIGHT CONNECTIONS TO SUPPORT STRUCTURE, AND SUPPORTING
FRAMING MEMBERS SHALL BE DESIGNED IN ACCORDANCE WITH ATFP CRITERIA FOR A 3
SECOND EQUIVALENT LOAD OF 160 PSF APPLIED UNIFORMLY TO DOOR, WINDOW, AND
SKYLIGHT AREAS.
CRANE DESIGN NOTES:
CR-1. OVERHEAD BRIDGE CRANE SHALL BE TOP RUNNING WITH CAPACITY OF 35 TONS.
CR-2. THE LOWEST PORTION OF THE CRANE SUPPORT STRUCTURE SHALL HAVE CLEARANCE HEIGHT OF 22’-0” MINIMUM AFF. THE OVERHEAD BRIDGE CRAN SHALL HAVE A MINIMUM HOOK HEIGHT OF
26'-0" AFF.
CR-3. CRANE SHALL BE DESIGNED FOR A CRANE SERVICE DUTY CLASSIFICATION OF CLASS C
(MODERATE SERVICE) AS DEFINED BY THE CRANE MANUFACTURER’S ASSOCIATION OF AMERICA
(CMAA).
CR-4. STRUCTURE SUPPORTING THE BRIDGE CRANE SHALL BE DESIGNED FOR THE TOTAL VERTICAL
LOAD FROM THE WEIGHT OF THE BRIDGE, TROLLEY HOIST, AND RATED CAPACITY OF THE
CRANE. TOTAL VERTICAL LOAD SHALL BE ADJUSTED FOR THE FOLLOWING IMPACT LOAD
FACTOR EXPRESSED AS A PERCENTAGE OF THE TOTAL VERTICAL LOAD. CRANE RUNWAY
BEAMS AND RAILS SHALL ALSO BE DESIGNED FOR A LATERAL AND LONGITUDINAL FORCE
EQUIVALENT TO A PERCENTAGE OF THE TOTAL VERTICAL LOAD AS SHOWN BELOW. SEE ASCE
7-10, SECTION 4.10 FOR DETAILS.
VERTICAL IMPACT FORCE 110%
LATERAL FORCE 20%
LONGITUDINAL FORCE 10%
CR-5. PROVIDE END STOPS AT EACH END OF CRANE RAIL. END STOPS SHALL BE DESIGNED FOR
LOADS REQUIRED FOR THE CRANE PROVIDED. CONTRACTOR SHALL COORDINATE LOCATIONS
OF CRANE STOPS WITH PEMB SUPPLIER AND CRANE PROVIDER.
CR-6. CRANE SUPPORT STRUCTURE SHALL BE DELEGATED AND DESIGNED BY CRANE SUPPLIER TO SUPPORT A 35 TON CAPACITY BRIDGE CRANE AS SPECIFIED IN THE MECHANICAL DRAWINGS AND
SPECIFICATIONS. PIERS AND FOUNDATIONS SHOWN FOR THE CRANE STRUCTURE ON SHEET
SF-502 ARE FOR PRICING ESTIMATES ONLY AND SHALL BE REDESIGNED BY THE CONTRATOR UPON
FINAL LOAD DETERMINATION. REFER TO SPECIFICATION SECTION 13 34 19 FOR ADDTIONAL
CRITERA.
STEEL CONSTRUCTION NOTES:
S-1. FABRICATION AND ERECTION OF STRUCTURAL STEEL AND DESIGN OF CONNECTIONS SHALL BE IN ACCORDANCE WITH AISC 360-10, "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS" DATED JUNE 22, 2010 AND AISC 303-10, "CODE OF STANDARD PRACTICE FOR BUILDING AND BRIDGES" DATED APRIL 14, 2010.
S-2. UNLESS OTHERWISE NOTED, STRUCTURAL STEEL SHALL BE IN ACCORDANCE WITH THE
ABOVE-LISTED AISC SPECIFICATION AND THE FOLLOWING:
A. WIDE FLANGE SHAPES (50 KSI) ASTM A992, GRADE B
B. HSS HOLLOW SHAPES (50 KSI) ASTM A500, GRADE C
B. PLATES AND ANGLES ASTM A36
C. HIGH STRENGTH BOLTS ASTM A325
D. ANCHOR RODS W/ NUT AND WASHER ASTM F1554, GRADE 36
S-3. ALL SHOP AND FIELD WELDING SHALL BE BE BY CERTIFIED WELDERS AND SHALL CONFORM TO AWS
STANDARDS. USE E70XX ELECTRODES UNLESS OTHERWISE NOTED. MINIMUM WELD SIZE FOR
STRUCTURAL STEEL IS 3/16" FILLET, UNLESS OTHERWISE NOTED ON PLANS. CURRENT AWS
CERTIFICATIONS SHALL BE AVAILABLE AT THE JOB SITE FOR REVIEW BY THE OWNERS'
REPRESENTATIVE.
STEEL CONSTRUCTION NOTES CONTINUED:
S-4. ALL BOLTED CONNECTIONS, UNLESS OTHERWISE NOTED, SHALL USE 3/4" DIAMETER HIGH
STRENGTH BOLTS WITH HARDENED CARBON STEEL WASHERS AS REQUIRED FOR THE
CONNECTION LOADS. IF LOADS ARE NOT INDICATED ON THE DRAWINGS, STEEL FABRICATOR
SHALL SIZE CONNECTIONS FOR A MINIMUM OF ONE HALF OF THE UNIFORM LOAD CAPACITY
OF THE BEAM AS INDICATED IN THE AISC MANUAL.
S-5. FIELD CUTTING OF STRUCTURAL STEEL MEMBERS BY ANY TRADE SHALL NOT BE PERMITTED.
BOLT HOLES SHALL NOT BE CUT OR ENLARGED BY FLAME CUTTING IN THE FIELD.
S-6. ALL FIELD-BOLTED SHEAR CONNECTIONS SHALL BE SNUG TIGHT BEARING-TYPE CONNECTIONS, THREADS INCLUDED IN THE SHEAR PLANE.
S-7. THE CONTRACTOR SHALL SUBMIT FOR APPROVAL DRAWINGS AND DESIGN CALCULATIONS
FOR ANY ALTERNATE DETAILS AND MEMBER SPLICES.
S-8. SHOP OR FIELD SPLICES OF STRUCTURAL STEEL MEMBERS ARE PROHIBITED EXCEPT AS DETAILED
ON THE DRAWINGS, PERMITTED IN THE SPECIFICATIONS, AS INDICATED ON APPROVED
SUBMITTALS, AND AS SPECIFICALLY APPROVED ON SHOP DRAWINGS PRIOR TO FABRICATION.
S-9. PAINT ALL STEEL BELOW GRADE WITH BITUMINOUS COATING.
S-10. ALL STEEL EXPOSED TO WEATHER SHALL BE HOT-DIPPED GALVANIZED IN ACCORDANCE WITH
ASTM A123 FOR MEMBERS AND ASTM A153 FOR CONNECTION ELEMENTS, EXCEPT THAT
ARCHITECTURALLY EXPOSED STRUCTURAL STEEL SHALL BE BLAST CLEANED AND COATED IN
ACCORDANCE WITH THE STRUCTURAL STEEL AND PAINT SPECIFICATIONS. COORDINATE ALL
STEEL FINISHES WITH ARCHITECTURAL DRAWINGS AND SPECIFICATIONS.
S-11. REFER TO SPECIFICATION 05 12 00 FOR ADDITIONAL INFORMATION.
MASONRY CONSTRUCTION NOTES:
M-1. ALL MASONRY CONSTRUCTION SHALL BE IN ACCORDANCE WITH "BUILDING
CODE REQUIREMENTS FOR MASONRY STRUCTURES" (ACI 530-13/ASCE 5-11/
TMS 402-11) AND "SPECIFICATION FOR MASONRY STRUCTURES" (ACI 530.1-13/
ASCE 6-11/TMS 602-11).
M-2. DESIGN MASONRY ASSEMBLAGE STRENGTH, f'm = 1500 PSI. NET AREA
COMPRESSIVE STRENGTH OF CONCRETE MASONRY UNITS SHALL BE A
MINIMUM OF 1900 PSI.
M-3. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90 AND BE
MANUFACTURED WITH NORMAL WEIGHT AGGREGATE.
M-4. GROUT SHALL CONFORM TO ASTM C476 AND SHALL NOT CONTAIN ADMIXTURES.
GROUT SHALL ATTAIN A MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 2000 PSI.
M-5. REINFORCEMENT SHALL BE DEFORMED BARS CONFORMING TO ASTM
A615/A615M, GRADE 60 AND SHALL HAVE FABRICATION TOLERANCES IN
ACCORDANCE WITH ACI 315. SHOP FABRICATE REINFORCING BARS WHICH ARE
INDICATED TO BE BENT OR HOOKED.
M-6. LOCATE JOINT REINFORCEMENT 16 INCHES ON CENTER VERTICALLY AND
ADDITIONALLY AT THE TOP OF ALL FOUNDATIONS AND IN THE TWO JOINTS
IMMEDIATELY ABOVE AND BELOW ALL OPENINGS, EXTENDING A MINIMUM
OF 24 INCHES BEYOND THE JAMB ON EACH SIDE.
M-7. PLACE PIPES AND CONDUITS PASSING HORIZONTALLY THROUGH MASONRY
IN STEEL OR PVC SLEEVES OR CORED HOLES UNLESS OTHERWISE
INDICATED ON THE DRAWINGS.
M-8. ALUMINUM CONDUITS, PIPES, AND ACCESSORIES SHALL NOT BE EMBEDDED
IN MASONRY GROUT, OR MORTAR, UNLESS EFFECTIVELY COATED OR COVERED
TO PREVENT ALUMINUM-CEMENT CHEMICAL REACTION OR ELECTROLYTIC
REACTION BETWEEN ALUMINUM AND STEEL.
M-9. UNLESS OTHERWISE NOTED OR DETAILED, CENTER WALL REINFORCEMENT
IN BLOCK CELLS. USE NONMETALLIC BAR POSITIONERS.
M-10. PROVIDE DOWEL REINFORCEMENT FROM WALLS INTO FOUNDATION OF SAME
SIZE AND SPACING AS VERTICAL WALL REINFORCEMENT. WHERE VERTICAL
REINFORCEMENT IS NON-CONTINUOUS, PROVIDE SPLICE LENGTH AS SHOWN
IN SCHEDULE ON S-601 U.N.O. ON PLANS.
SPECIAL INSPECTION NOTES:
SI-1. INSPECTION OF FABRICATORS SHALL BE CONDUCTED IN ACCORDANCE WITH
IBC 2015, SECTION 1704.2.
SI-2. INSPECTION OF STEEL CONSTRUCTION SHALL BE CONDUCTED IN ACCORDANCE
WITH IBC 2015, SECTION 1705.2 AND TABLE 1705.2.3
SI-3. INSPECTION OF CONCRETE CONSTRUCTION SHALL BE CONDUCTED IN ACCORDANCE
WITH IBC 2015, SECTION 1705.3 AND TABLE 1705.3.
SI-4. INSPECTION OF MASONRY CONSTRUCTION SHALL BE CONDUCTED IN ACCORDANCE
WITH IBC 2015, SECTION 1705.4.
SI-5. INSPECTIONS FOR SEISMIC RESISTANCE SHALL BE AS PER IBC 2015, SECTION 1705.12.
SI-6. INCLUDE SPECIAL INSPECTIONS REQUIREMENTS IN CONTRACTOR'S QUALITY
CONTROL (CQC) PLAN.
SI-7. THE CONTRACTOR SHALL RETAIN THIRD PARTY QUALITY ASSURANCE AGENCIES
TO CONDUCT SPECIAL INSPECTIONS REQUIRED BY IBC. INSPECTING AGENCY
SHALL PROVIDE REPORTS OF SPECIAL INSPECTIONS DIRECTLY TO THE
GOVERNMENT.
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
E C
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
S I
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENDKRW\Documents\FY18PN80855_STRUC_R15_K6ENDKRW.rvt
3/1/2018 7:08:33 AM
M
AR
C H
W
2H N
-1 8-
R -3
P.
H ag er
P.
H ag er
C . M ck en zi e
C
AT
C O
D E
S-001
G
EN
ER
AL
S T R
U C
T U R
AL
N
O
TE
S
SA
VA
N N
AH
D
IS
TR
IC
T
Sa va nn ah
, G e o rg ia
F O R
T
BE
N N
IN
G
, G
EO
R G
I A
TR
A I N
IN
G
S U
PP
O
R T
FA
C
IL
IT
Y P N
5 5
J.
W hi tta ke r
ISSUED FOR CONSTRUCTION
M
AR
K D
ES
C
R
IP
TI
O
N D
STRUCTURAL ABBREVIATIONS
SYMBOL DESCRIPTION
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
APPROX APPROXIMATELY
ARCH ARCHITECTURAL
BOC BOTTOM OF CONCRETE
BOF BOTTOM OF FOOTING
BOM BOTTOM OF MASONRY
BOS BOTTOM OF STEEL
BOT BOTTOM
BRG BEARING
CJ CONSTRUCTION JOINT
CL CENTER LINE
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONN CONNECTION
CONC CONCRETE
CONT. CONTINUOUS
CONSTR CONSTRUCTION
DCJ DOWELED CONSTRUCTION JOINT
DEG DEGREE
DIA DIAMETER
DN DOWN
DWG(S) DRAWING(S)
EA EACH
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION
EOF EDGE OF FOUNDATION
EQ EQUAL
ERV ENERGY RECOVERY VENTILATOR
EW EACH WAY
FF FINISHED FLOOR
FDN FOUNDATION
FTG FOOTING
GA GAUGE
GALV GALVANIZED
GFGI GOVT
HORIZ HORIZONTAL
KIP (k) 1000 POUNDS
LG LONG
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
MAX MAXIMUM
MECH MECHANICAL
MEP MECHANICAL, ELECTRICAL, PLUMBING
MFR MANUFACTURER
MIN MINIMUM
NTS NOT TO SCALE
OC ON CENTER
OPP OPPOSITE
PEMB PRE-ENGINEERED METAL BUILDING
PJF PREMOLDED JOINT FILLER
PL PLATE
PLF POUNDS PER LINEAR FOOT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
REINF REINFORCEMENT
REQD REQUIRED
SCHED SCHEDULE
SE SLAB EDGE
SJ SAWED CONTRACTION JOINT
SJI STEEL JOIST INSTITUTE
SIM SIMILAR
SL SLOPE(D)
SOG SLAB ON GRADE
STD STANDARD
T&B TOP AND BOTTOM
TO TOP OF
TOC TOP OF CONCRETE
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOS TOP OF SLAB
TS THICKENED SLAB
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VEF VEHICLE EXHAUST FAN
VERT VERTICAL
WP WORKING POINT
WWF WELDED WIRE FABRIC
STRUCTURAL LEGEND
SLOPE DIRECTION
INDICATES ELEVATION REFERENCED
TO FINISHED FLOOR
KEYED PLAN NOTE
COLUMN REFERENCE LINE
(CENTER LINE OF COLUMN)
SPOT ELEVATION
SLAB DEPRESSION
BRICK WALL
CONCRETE ELEMENT
EARTH FILL
GROUT
CONCRETE MASONRY UNIT (CMU)
POROUS FILL
WELDED WIRE FABRIC (WWF)
DN
X
[+/- X’-X”]
X
[+/- X’-X”]
+22/ -36
ZONE
ROOF
TRAINING SUPPORT FACILITY
COMPONENT AND CLADDING WIND PRESSURES (PSF)
10 SF
EFFECTIVE
WIND
AREA 1
WALLOVERHANG
1. WIND PRESSURES SHOWN ABOVE CORRESPOND TO WIND
PRESSURE DIAGRAMS.
2. EDGE ZONES 'a' = 16'-0"
3. WIND PRESSURES SHOWN SHALL BE USED IN CONJUNCTION WITH LOAD
COMBINATIONS SPECIFIED IN SECTIONS 2.3 AND 2.4 OF ASCE 7-10.
4. NEGATIVE WIND PRESSURES REPRESENT WIND PRESSURES ACTING
AWAY FROM THE COMPONENT AND CLADDING SURFACES.
20 SF
50 SF
100 SF
+21 / -35
+18 / -34
+16 / -33
+23 / -63
+21 / -58
+17 / -51
+16 / -46
+22 / -93
+21 / -86
+18 / -78
+16/ -73
+39 / -43
+38/ -50
+34 / -49
+34 / -49
+33 / -56
+32 / -52
+30 / -45
+28 / -41
-80
-93
-93
-93
-162
-146
-124
-117
ZONE 2 ZONE 3 ZONE 4 ZONE 5ZONE 2 ZONE 3
'a' = 16'
(TYP)
'a' = 16'
(TYP)
WALL ZONES
11 1 1
222 2 2
3 3
2 2
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
E C
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
S I
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENDKRW\Documents\FY18PN80855_STRUC_R15_K6ENDKRW.rvt
3/1/2018 7:08:35 AM
M
AR
C H
W
2H N
-1 8-
R -3
P.
H ag er
P.
H ag er
C . M ck en zi e
C
AT
C O
D E
S-002
G
EN
ER
AL
S T R
U C
T U R
AL
N
O
TE
S
SA
VA
N N
AH
D
IS
TR
IC
T
Sa va nn ah
, G e o rg ia
F O R
T
BE
N N
IN
G
, G
EO
R G
I A
TR
A I N
IN
G
S U
PP
O
R T
FA
C
IL
IT
Y P N
5 5
J.
W hi tta ke r
ISSUED FOR CONSTRUCTION
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
ROOF ZONES
B
1 2 3 4 5 6 7 8 9 10 11A 12 13 14 15 16 17 18 19 20 22
631' - 0"
A.2
A.5
A.8
B.2
B.5
B.8
A.3
A.6
B.3
B.6
C
A
11B
EXPANSION
JOINT LOCATION
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
E C
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
S I
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENDKRW\Documents\FY18PN80855_STRUC_R15_K6ENDKRW.rvt
3/1/2018 7:08:39 AM
M
AR
C H
W
2H N
-1 8-
R -3
P.
H ag er
P.
H ag er
C . M ck en zi e
C
AT
C O
D E
SB101
FL
O
O R
P
LA
N
C O
M
PO
SI
TE
SA
VA
N N
AH
D
IS
TR
IC
T
Sa va nn ah
, G e o rg ia
F O R
T
BE
N N
IN
G
, G
EO
R G
I A
TR
A I N
IN
G
S U
PP
O
R T
FA
C
IL
IT
Y P N
5 5
J.
W hi tta ke r
ISSUED FOR CONSTRUCTION
TRUE NORTHPLAN NORTH
KEY PLAN
PART A PART B PART C PART D PART E
FLOOR PLAN - COMPOSITE1 16 32 6482432
SCALE: 1/32"=1'-0"
M
AR
K D
ES
C
R
IP
TI
O
N D
1 2 3 4 5 6 7
30' - 6" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 30' - 0"
A.3
A.6
B.3
B.6
C
A
CF10.0
CF8.0
CF10.0 CF10.0 CF10.0 CF10.0
CF10.0
CF8.0
CF6.0
CF6.0
CF6.0
CF6.0
CF6.0
SF302
SB502
M
AT
C H
LI
N
E M
AT
C
H
LI
N E
SB
SB
CF8.0 CF8.0 CF8.0 CF8.0 CF8.0
CF8.0 CF8.0 CF8.0 CF8.0
HAIR PIN
(TYP.)
CF8.0
CF8.0
11" SLAB ON GRADE
(SEE NOTES)
SB502
Sim 4
SB502
Sim
BRACED FRAME
BRACED FRAME
P1P1
P3
P3
P3
P1
P3
P3
P1P1P1 P1
P1 P1 P1 P1 P1 P1
P1 P1 P1 P1 P1 P1
P3
CF8.0
1' - 4"
1'
4" 1'
4"
SEE NOTE 17
1'
4" 1'
4"
1. FOR GENERAL STRUCTURAL NOTES AND ABBREVIATIONS,
SEE S-001.
2. SEE SF301-SF303 AND FOLLOWING FOR FRAME SECTIONS.
3. SEE SB501 AND FOLLOWING FOR FOUNDATION SECTIONS
AND DETAILS.
4. TOP OF CONCRETE SLAB-ON-GRADE ELEVATION = 0'-0".
ALL ELEVATIONS INDICATED FROM THIS DATUM. SEE CIVIL
FOR EXACT ELEVATION.
5. P-X INDICATES CONCRETE PIER. SEE PIER SCHEDULE ON
SB601 FOR SIZE AND REINFORCEMENT.
6. CF-X INDICATES FOOTING FOUNDED IN SOIL WITH AN
ALLOWABLE BEARING CAPACITY OF 3,000 PSF AS DEFINED IN
THE FOUNDATION NOTES ON S-001. SEE FOOTING
SCHEDULE ON SB601
7. ALL FOOTINGS SHALL BE CENTERED UNDER PIERS UNO.
8. TOP OF FTG. = (-) 2'- 0" UNO.
9. PIERS AND FOUNDATIONS SUPPORTING PEMB COLUMNS
ARE PRELIMINARY FOR ESTIMATING PURPOSES ONLY AND
ARE NOT FINAL. THE CONTRACTOR SHALL BE RESPONSIBLE
FOR FINAL DESIGN OF PEMB PIERS AND FOUNDATIONS
BASED ON FINAL PEMB REACTIONS WHEN FINAL MAXIMUM
REACTIONS ARE DIFFERENT FROM THE REACTIONS SHOWN
ON SB601. SEE GENERAL NOTES FOR ADDITIONAL
INFORMATION.
10. SLAB-ON-GRADE BETWEEN COLUMN LINES 1 THRU 20 SHALL
CONSIST OF 11" THICK CONCRETE SLAB REINFORCED WITH #
4 BAR @ 12" O.C. EACH WAY LOCATED AT TOP AND BOTTOM
OF SLAB.
11. 5" SLAB-ON-GRADE BETWEEM COLUMN LINES 20 THRU 22
SHALL BE WITH (1) LAYER OF 6X6 W4.0XW4.0 WWF LOCATED
CENTER OF SLAB.
12. SLAB-ON-GRADE AT ALL INTERIOR CONDITIONS SHALL BE
PLACED ON 10 MIL VAPOR RETARDER ON A 4" LAYER OF
COMPACTED GRANULAR FILL.
13. PROVIDE (1) #5 X 4'-0" LONG AT CENTER OF
SLAB-ON-GRADE AT ALL RE-ENTRANT CORNERS AND
WHERE A CONTROL JOINT TERMINATES AT A CONTROL
JOINT.
14. JOINT LOCATIONS DENOTED BY S.J. ARE DIAGRAMMATIC
ONLY AND DO NOT REPRESENT ALL JOINTS REQUIRED
FOR SLAB CONSTRUCTION. CONTRACTOR SHALL
COORDINATE SLAB-ON-GRADE REQUIREMENTS WITH SLAB-
ON-GRADE CONSTRUCTION SEQUENCING AND SLAB DETAILS
ON SB501. JOINT SPACING SHALL NOT EXCEED MAXIMUM
JOINT SPACING PER ACI REQUIREMENTS.
15. COORDINATE UNDERGROUND UTILITY LINES WITH CIVIL,
PLUMBING, AND FIRE PROTECTION DRAWINGS PRIOR TO
CONSTRUCTION OF FOOTINGS AND SLABS-ON-GRADE.
16. SLOPE CONCRETE TO DRAINS AS SHOWN AT 1/8" PER FOOT.
17. FOR FOOTINGS AT BALLARD LOCATIONS SEE DETAIL 6/SB502.
NUMBER OF LOCATIONS THAT REQUIRE FOOTING DETAIL
6/SB502 WILL MAY VARY BASED ON THE CONTRACTORS
FINAL FOUNDATION DESIGN.
18. CW-X DENOTES CMU WALLS. SEE SCHEDULE ON SB601
19. WX DENOTES WALL FOOTING. SEE SCHEDULE ON SB601
FLOOR DRAIN
RE-ENTRANT CORNER BARS
12 INCH CMUFD
8" DIAMETER BOLLARD MECH EQUIP PAD
5" SLAB ON GRADE
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
E C
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
S I
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENDKRW\Documents\FY18PN80855_STRUC_R15_K6ENDKRW.rvt
3/1/2018 7:08:42 AM
M
AR
C H
W
2H N
-1 8-
R -3
P.
H ag er
P.
H ag er
C . M ck en zi e
C
AT
C O
D E
SB102
FL
O
O R
P
LA
N
PA
R
T A
SA
VA
N N
AH
D
IS
TR
IC
T
Sa va nn ah
, G e o rg ia
F O R
T
BE
N N
IN
G
, G
EO
R G
I A
TR
A I N
IN
G
S U
PP
O
R T
FA
C
IL
IT
Y P N
5 5
J.
W hi tta ke r
ISSUED FOR CONSTRUCTION
TRUE NORTHPLAN NORTH
KEY PLAN
PART A PART B PART C PART D PART E
FLOOR PLAN - PART A1 0
SCALE: 3/32"=1'-0"
816 16
FLOOR PLAN NOTES
PLAN LEGEND
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
SJ
BB
6 7 8 9 10 11A
A.2
A.5
A.8
B.2
B.5
B.8
30' - 0" 30' - 0" 30' - 0" 30' - 0" 28' - 11"
A.3
A.6
B.3
B.6
C
A
SJ
SJ
CF10.0 CF10.0 CF10.0 CF10.0CF10.0
CF10.0
M
AT
C H
LI
N
E M
AT
C
H
LI
N E
M
AT
C H
IN
E
M
AT
C H
IN
E
SB
SB
SB
SB
CF8.0 CF8.0
CF8.0 CF8.0 CF8.0 CF10.0
CF8.0
CF8.0 CF8.0 CF8.0 CF8.0 CF10.0
HAIRPIN
(TYP.)
11" SLAB ON GRADE
(SEE NOTES)
P1 P1
P1 P1
P1 P1
P1 P1 P2P1
P1 P1 P1 P2
P1 P1 P1 P2
BRACED FRAME
BRACED FRAME
11B
BOLLARD
SB502
Sim
SB502
Sim
SB502
Sim
SLAB EXPANSION JOINT
BETWEEN GRID LINES 11A
& 11B. (SEE DETAIL 3/SB501)
2' - 2"
WALK OFF MATT RECESS
SEE DETAIL 6/SB501 AND
COORDINATE WITH
ARCHITECTURAL DRAWINGS.
1'
4" 1'
4"
1. FOR GENERAL STRUCTURAL NOTES AND ABBREVIATIONS,
SEE S-001.
2. SEE SF301-SF303 AND FOLLOWING FOR FRAME SECTIONS.
3. SEE SB501 AND FOLLOWING FOR FOUNDATION SECTIONS
AND DETAILS.
4. TOP OF CONCRETE SLAB-ON-GRADE ELEVATION = 0'-0".
ALL ELEVATIONS INDICATED FROM THIS DATUM. SEE CIVIL
FOR EXACT ELEVATION.
5. P-X INDICATES CONCRETE PIER. SEE PIER SCHEDULE ON
SB601 FOR SIZE AND REINFORCEMENT.
6. CF-X INDICATES FOOTING FOUNDED IN SOIL WITH AN
ALLOWABLE BEARING CAPACITY OF 3,000 PSF AS DEFINED IN
THE FOUNDATION NOTES ON S-001. SEE FOOTING
SCHEDULE ON SB601
7. ALL FOOTINGS SHALL BE CENTERED UNDER PIERS UNO.
8. TOP OF FTG. = (-) 2'- 0" UNO.
9. PIERS AND FOUNDATIONS SUPPORTING PEMB COLUMNS
ARE PRELIMINARY FOR ESTIMATING PURPOSES ONLY AND
ARE NOT FINAL. THE CONTRACTOR SHALL BE RESPONSIBLE
FOR FINAL DESIGN OF PEMB PIERS AND FOUNDATIONS
BASED ON FINAL PEMB REACTIONS WHEN FINAL MAXIMUM
REACTIONS ARE DIFFERENT FROM THE REACTIONS SHOWN
ON SB601. SEE GENERAL NOTES FOR ADDITIONAL
INFORMATION.
10. SLAB-ON-GRADE BETWEEN COLUMN LINES 1 THRU 20 SHALL
CONSIST OF 11" THICK CONCRETE SLAB REINFORCED WITH #
4 BAR @ 12" O.C. EACH WAY LOCATED AT TOP AND BOTTOM
OF SLAB.
11. 5" SLAB-ON-GRADE BETWEEM COLUMN LINES 20 THRU 22
SHALL BE WITH (1) LAYER OF 6X6 W4.0XW4.0 WWF LOCATED
CENTER OF SLAB.
12. SLAB-ON-GRADE AT ALL INTERIOR CONDITIONS SHALL BE
PLACED ON 10 MIL VAPOR RETARDER ON A 4" LAYER OF
COMPACTED GRANULAR FILL.
13. PROVIDE (1) #5 X 4'-0" LONG AT CENTER OF
SLAB-ON-GRADE AT ALL RE-ENTRANT CORNERS AND
WHERE A CONTROL JOINT TERMINATES AT A CONTROL
JOINT.
14. JOINT LOCATIONS DENOTED BY S.J. ARE DIAGRAMMATIC
ONLY AND DO NOT REPRESENT ALL JOINTS REQUIRED
FOR SLAB CONSTRUCTION. CONTRACTOR SHALL
COORDINATE SLAB-ON-GRADE REQUIREMENTS WITH SLAB-
ON-GRADE CONSTRUCTION SEQUENCING AND SLAB DETAILS
ON SB501. JOINT SPACING SHALL NOT EXCEED MAXIMUM
JOINT SPACING PER ACI REQUIREMENTS.
15. COORDINATE UNDERGROUND UTILITY LINES WITH CIVIL,
PLUMBING, AND FIRE PROTECTION DRAWINGS PRIOR TO
CONSTRUCTION OF FOOTINGS AND SLABS-ON-GRADE.
16. SLOPE CONCRETE TO DRAINS AS SHOWN AT 1/8" PER FOOT.
17. FOR FOOTINGS AT BALLARD LOCATIONS SEE DETAIL 6/SB502.
NUMBER OF LOCATIONS THAT REQUIRE FOOTING DETAIL
6/SB502 WILL MAY VARY BASED ON THE CONTRACTORS
FINAL FOUNDATION DESIGN.
18. CW-X DENOTES CMU WALLS. SEE SCHEDULE ON SB601
19. WX DENOTES WALL FOOTING. SEE SCHEDULE ON SB601
FLOOR DRAIN
RE-ENTRANT CORNER BARS
12 INCH CMUFD
8" DIAMETER BOLLARD MECH EQUIP PAD
5" SLAB ON GRADE
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
E C
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
S I
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENDKRW\Documents\FY18PN80855_STRUC_R15_K6ENDKRW.rvt
3/1/2018 7:08:46 AM
M
AR
C H
W
2H N
-1 8-
R -3
P.
H ag er
P.
H ag er
C . M ck en zi e
C
AT
C O
D E
SB103
FL
O
O R
P
LA
N
PA
R
T B
SA
VA
N N
AH
D
IS
TR
IC
T
Sa va nn ah
, G e o rg ia
F O R
T
BE
N N
IN
G
, G
EO
R G
I A
TR
A I N
IN
G
S U
PP
O
R T
FA
C
IL
IT
Y P N
5 5
J.
W hi tta ke r
ISSUED FOR CONSTRUCTION
FLOOR PLAN - PART B1 0
SCALE: 3/32"=1'-0"
816 16
FLOOR PLAN NOTES
TRUE NORTHPLAN NORTH
KEY PLAN
PART A PART B PART C PART D PART E
PLAN LEGEND
M
AR
K D
ES
C
R
IP
TI
O
N D
10 11A 12 13 14 15
A.2
A.5
A.8
B.2
B.5
B.8
28' - 11" 31' - 1" 30' - 0" 30' - 0" 30' - 0"
A.3
A.6
B.3
B.6
C
A
CF10.0
CF10.0CF10.0CF10.0CF10.0 CF10.0
M
AT
C H
IN
E
M
AT
C H
IN
E
M
AT
C H
IN
E
M
AT
C H
IN
E
SB
SB
SB
SB
CF8.0
CF8.0 CF8.0
CF8.0 CF10.0
CF8.0 CF10.0
CF8.0 CF8.0
CF8.0
CF8.0 CF8.0
HAIRPIN
(TYP.)
11" SLAB ON GRADE
(SEE NOTES)
SLAB EXPANSION JOINT
BETWEEN GRID LINES
11A & 11B (SEE DETAIL SB501)
P1 P2
P1 P2
P1 P2
P1 P1 P1P1
P1 P1 P1 P1
P1 P1 P1 P1
BRACED FRAME
BRACED FRAME
11B
BOLLARDBOLLARD
SB502
Sim
SB502
Sim
SB502
Sim
2' - 2"
1. FOR GENERAL STRUCTURAL NOTES AND ABBREVIATIONS,
SEE S-001.
2. SEE SF301-SF303 AND FOLLOWING FOR FRAME SECTIONS.
3. SEE SB501 AND FOLLOWING FOR FOUNDATION SECTIONS
AND DETAILS.
4. TOP OF CONCRETE SLAB-ON-GRADE ELEVATION = 0'-0".
ALL ELEVATIONS INDICATED FROM THIS DATUM. SEE CIVIL
FOR EXACT ELEVATION.
5. P-X INDICATES CONCRETE PIER. SEE PIER SCHEDULE ON
SB601 FOR SIZE AND REINFORCEMENT.
6. CF-X INDICATES FOOTING FOUNDED IN SOIL WITH AN
ALLOWABLE BEARING CAPACITY OF 3,000 PSF AS DEFINED IN
THE FOUNDATION NOTES ON S-001. SEE FOOTING
SCHEDULE ON SB601
7. ALL FOOTINGS SHALL BE CENTERED UNDER PIERS UNO.
8. TOP OF FTG. = (-) 2'- 0" UNO.
9. PIERS AND FOUNDATIONS SUPPORTING PEMB COLUMNS
ARE PRELIMINARY FOR ESTIMATING PURPOSES ONLY AND
ARE NOT FINAL. THE CONTRACTOR SHALL BE RESPONSIBLE
FOR FINAL DESIGN OF PEMB PIERS AND FOUNDATIONS
BASED ON FINAL PEMB REACTIONS WHEN FINAL MAXIMUM
REACTIONS ARE DIFFERENT FROM THE REACTIONS SHOWN
ON SB601. SEE GENERAL NOTES FOR ADDITIONAL
INFORMATION.
10. SLAB-ON-GRADE BETWEEN COLUMN LINES 1 THRU 20 SHALL
CONSIST OF 11" THICK CONCRETE SLAB REINFORCED WITH #
4 BAR @ 12" O.C. EACH WAY LOCATED AT TOP AND BOTTOM
OF SLAB.
11. 5" SLAB-ON-GRADE BETWEEM COLUMN LINES 20 THRU 22
SHALL BE WITH (1) LAYER OF 6X6 W4.0XW4.0 WWF LOCATED
CENTER OF SLAB.
12. SLAB-ON-GRADE AT ALL INTERIOR CONDITIONS SHALL BE
PLACED ON 10 MIL VAPOR RETARDER ON A 4" LAYER OF
COMPACTED GRANULAR FILL.
13. PROVIDE (1) #5 X 4'-0" LONG AT CENTER OF
SLAB-ON-GRADE AT ALL RE-ENTRANT CORNERS AND
WHERE A CONTROL JOINT TERMINATES AT A CONTROL
JOINT.
14. JOINT LOCATIONS DENOTED BY S.J. ARE DIAGRAMMATIC
ONLY AND DO NOT REPRESENT ALL JOINTS REQUIRED
FOR SLAB CONSTRUCTION. CONTRACTOR SHALL
COORDINATE SLAB-ON-GRADE REQUIREMENTS WITH SLAB-
ON-GRADE CONSTRUCTION SEQUENCING AND SLAB DETAILS
ON SB501. JOINT SPACING SHALL NOT EXCEED MAXIMUM
JOINT SPACING PER ACI REQUIREMENTS.
15. COORDINATE UNDERGROUND UTILITY LINES WITH CIVIL,
PLUMBING, AND FIRE PROTECTION DRAWINGS PRIOR TO
CONSTRUCTION OF FOOTINGS AND SLABS-ON-GRADE.
16. SLOPE CONCRETE TO DRAINS AS SHOWN AT 1/8" PER FOOT.
17. FOR FOOTINGS AT BALLARD LOCATIONS SEE DETAIL 6/SB502.
NUMBER OF LOCATIONS THAT REQUIRE FOOTING DETAIL
6/SB502 WILL MAY VARY BASED ON THE CONTRACTORS
FINAL FOUNDATION DESIGN.
18. CW-X DENOTES CMU WALLS. SEE SCHEDULE ON SB601
19. WX DENOTES WALL FOOTING. SEE SCHEDULE ON SB601
FLOOR DRAIN
RE-ENTRANT CORNER BARS
12 INCH CMUFD
8" DIAMETER BOLLARD MECH EQUIP PAD
5" SLAB ON GRADE
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
E C
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
S I
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6E…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.