A.02.02__Amendment_0003_Drawing__2.pdf
PDF 292 KB Posted
- Solicitation number
- W912HN18Q5022
About this file
Amendment 0003 Drawing #2
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
W V
T
T
T
EEEEEEEEEEEEEE
T
T
T
E
T
E E
E E
E E
E E
E E
E E
E E E E E E E E E E E E E E E E E E E
E
E
W W
W
T
T
T T T
T T T T T T
T
T
T
G
MW
MW
MW
MW
MW
MW
MW
MW
MW
MW
MW
MW
MW
MW
MW
MW
MW
W
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
T
T
T
MW
GE
N
PA
D
XFMR
PAD
AC
PAD
WM
GM
W M
W V
W M
2'X2' DI
Grate = 490.70'
Inv = 487.50'
2'X2' DI
Grate = 490.50'
Inv = 487.00'
GM
G
MW
GM
WM
WM
E E E E E
500 495 493
495495
490 485
CP 2 (REBAR & ALUM. CAP)
N 1,246,476.77'
E 653,275.18'
ELEV = 495.84'
CP 3 (REBAR & PLASTIC CAP)
N 1,246,175.61'
E 653,279.43'
ELEV = 488.93'
Inv = 487.5' Inv = 486.6'
24" RCP
Inv = 485.0' Inv = 484.8'
24" RCP
Top = 491.0' Throat = 489.1'
Top = 491.0'
SS
SS
SS
SS
SS
SS
SS
SS
Oil Separator Rim = 489.9'
Rim = 483.5'
Rim = 490.4'
CHAMBERLAIN AVENUE
TH
S
TR
EE
T
8TH AVENUE
BUILDING 13800
FFE = 491.23'
BUILDING 13803
FFE = 492.30'
BU
IL
DI
N
G
FF
E
2.
X
X X
X
X
X
X
X
X X
X X
X X
X X
X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X X
X X
X X
X X
X X
X
X
X
X
X
SS
SS
SS
G G
G G
G
W W
W
151.76'
35.71'
102.05'
105.65'
81.39'
168.27'
190.05'
77.95'
27.43'
14.91'
14.90'
15.00'
35.49'
64.00'
24.50'
N: 1246407.37
E: 653408.87
N: 1246406.18
E: 653485.10
A N
S I
D
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
J U
N E
W H
N D
SHEET ID
ISSUED FOR CONSTRUCTION
F I L E
N A
M E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
A
M A
R K
S I Z
E
S U
B M
I T
T E
D
B
Y
D A
T E
C O
N T
R A
C T
O
US Army Corps of Engineers
C A
T E
G O
R Y
D
E
U S
A
R M
Y
C
O R
P S
F
E
N G
I N
E E
R S
W
E S
T
O
G L
E T
H O
R P
E
A
V E
N U
E
D E
S C
R I P
T I O
N
M
I C
H I G
A
V E
S U
I T
E
C H
I C
A G
O
I L
T w w w e x p f e d e r a l c o m p r o j n o
C
H I
A
S A
V A
N N
H
D
I S
T R
I C
T
S A
V A
N N
A H
G
E O
R G
I A
R E
N O
V A
T I O
N
A
D D
I T
I O
N
T
O
F
I R
E
S
T A
T I O
N
B
L D
G
P R
O J E
U M
B E
R
D
E
P
F O
R
G
R
D O
N
G
P
Z
I N
N I
LEGEND:
NEW WORK AREA
NEW WORK: CONCRETE PAVEMENT TO BE REMOVED
NEW WORK: ASPHALT PAVEMENT TO BE REMOVED
CONCRETE PAVEMENT TO BE REMOVED
CONCRETE CURB TO BE REMOVED
ASPHALT PAVEMENT TO BE REMOVED
OPTION: MILL 2'' OF ASPHALT, REFER TO CP101
LIMITS OF CONSTRUCTION
X
KEYNOTES
NEW WORK: CONTRACTOR TO REMOVE EXISTING OIL AND WATER SEPARATOR AND ALL
APPURTENANCES ACCORDING TO EPA REQUIREMENTS. REMOVE EXISTING SEWER LINE UP
TO LIMITS OF ASPHALT REPLACEMENT, PLUG ENDS WITH DRY PACK GROUT (ASTM C1107)
AND FILL ABANDONED LATERAL WITH FLOWABLE FILL
NEW WORK: CONTRACTOR TO REMOVE EXISTING 5 BOLLARDS
CONTRACTOR TO SAWCUT AND REMOVE EXISTING ASPHALT AS NEEDED FOR ADDITION TO
BUILDING 13803, REF. LEGEND AND SHEET CP101 FOR EXACT LIMITS OF PAVEMENT WORK
SOME MONITORING WELLS WEST OF BUILDING 13803 HAVE BEEN REMOVED BY OTHERS,
CONTACT DPW ENVIRONMENTAL FOR ADDITIONAL INFORMATION
ALL MONITORING WELLS SOUTH OF BUILDING 13803 TO REMAIN, CONTACT FORT GORDON
ENVIRONMENTAL FOR ADDITIONAL INFORMATION
CONTRACTOR TO REMOVE EXISTING 13' X 15' CONCRETE SLAB AND GRATE (DIRT FILL
BENEATH), TYP. OF 2
CONTRACTOR TO REMOVE EXISTING FENCE (APPROXIMATELY 1020 LF)
CONTRACTOR TO SAW CUT AND REMOVE APPROXIMATELY 3100 SF EXISTING CONCRETE
APRON, REF. LEGEND
CONTRACTOR TO SAWCUT AND REMOVE CURB
CONTRACTOR TO REMOVE EXISTING AC PAD
CONTRACTOR TO RELOCATE THE EXISTING ANTENNA, REF CS101
NEW VEHICLE GATE INSTALLED AFTER SURVEY TO REMAIN & BE PROTECTED DURING
DEMOLITION
PROTECT EXISTING TREE DURING CONSTRUCTION AS ALLOWABLE
CONTRACTOR TO PROVIDE 64' X 24.5' TRAILER TO ACT AS A TEMPORARY FIRE STATION
DURING CONSTRUCTION
CONTRACTOR TO PROVIDE TWO CONCRETE JERSEY BARRIERS THROUGHOUT THE
DURATION OF CONSTRUCTION TO LIMIT TEMPORARY FIRE STATION ACCESS FROM THE
EAST PARKING ENTRANCE
CONTRACTOR TO PROVIDE SIGNAGE STATING: FIRE DEPARTMENT TRAFFIC ONLY
CD101
C I V
I L
D E
M O
L I T
I O
N
P
L A
N
L R
O B
E R
T S
S S
A N
T E
L I K
L R
O B
E R
T S
F G
F S
C
D D
W G
NOTES:
1. LIMITS OF NEW PAVING AS SHOWN ON SHEET CP101. EXISTING PAVEMENT SHALL BE SAWCUT
FULL DEPTH AT LIMITS. SAWCUT LINES SHALL BE STRAIGHT, UNIFORM AND AT 90° ANGLES
WHEN APPLICABLE.
2. PROTECT EXISTING CONTROL POINTS AND MONUMENTS DURING CONSTRUCTION.
3. LAYDOWN AREA SHALL BE SET WITHIN THE CONSTRUCTION LIMITS AND MAY BE RELOCATED AS
NEEDED DURING CONSTRUCTION
0 30'
SCALE: 1"= 30'
60'
N
Lorraine Roberts 06/15/2018 k6cdgree Rectangle k6cdgree Line k6cdgree Line k6cdgree Line k6cdgree Text Box Swing Space k6cdgree Text Box Comm Room in Bldg. 13804 k6cdgree Text Box Approximate aerial routing of comm line from Bldg. 13804 to swing space
File details come from the government source that posted it.