CONTRACTOR SHALL FIELD VERIFY ALL JOB CONDITIONS
AND DIMENSIONS. VARIATIONS OR DISCREPANCIES SHALL
BE REPORTED TO THE POINT OF CONTACT (POC)
IMMEDIATELY AND WORK ON THE AFFECTED AREA SHALL
NOT PROCEED UNTIL DIRECTED BY THE POC.
IF CERTAIN FEATURES ARE NOT FULLY SHOWN OR CALLED
FOR ON THE DRAWINGS OR SPECIFICATIONS, THEIR
CONSTRUCTION SHALL BE OF THE SAME CHARACTER AS
FOR SIMILAR CONDITIONS. CONTRACTOR SHALL VERIFY
ALL EXISTING CONDITIONS AND DIMENSIONS AT JOB SITE .
ANY CONDITIONS REQUIRING CONSTRUCTION DIFFERENT
FROM THAT SHOWN ON THE PLANS SHALL BE BROUGHT TO
THE ATTENTION OF THE POC.
MATERIALS AND PRODUCTS SPECIFIED BY NAME OR
MODEL NUMBER SHALL NOT BE SUBSTITUTED WITHOUT
APPROVAL OF THE POC.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR
COORDINATING THE WORK OF ALL TRADES AND SHALL
CHECK ALL DIMENSIONS AND HOLES AND OPENINGS
REQUIRED IN STRUCTURAL MEMBERS. ALL DISCREPANCIES
SHALL BE CALLED TO THE ATTENTION OF THE POC AND
SHALL BE RESOLVED BEFORE PROCEEDING WITH THE
WORK.
THE CONTRACT DOCUMENTS REPRESENT THE FINISHED
STRUCTURE. THEY DO NOT INDICATE THE METHOD OF
CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL
MEASURES NECESSARY TO PROTECT LIFE AND PROPERTY
DURING CONSTRUCTION. SUCH MEASURES SHALL
INCLUDE, BUT ARE NOT LIMITED TO, BRACING AND
SHORING FOR LOADS DUE TO CONSTRUCTION AND
MATERIALS.
THE REMOVAL, CUTTING, DRILLING, ETC. OF EXISTING
WORK SHALL BE PERFORMED WITH CARE IN ORDER NOT
TO JEOPARDIZE THE STRUCTURAL INTEGRITY OF THE
BUILDING. IF STRUCTURAL MEMBERS OR MECHANICAL,
ELECTRICAL OR ARCHITECTURAL FEATURES NOT
INDICATED FOR REMOVAL INTERFERES WITH THE NEW
WORK, THE POC SHALL BE IMMEDIATELY NOTIFIED AND
PRIOR APPROVAL SHALL BE OBTAINED BEFORE REMOVAL
OF MEMBERS.
THE CONTRACTOR SHALL SAFELY SHORE EXISTING
CONSTRUCTION WHEREVER EXISTING SUPPORTS ARE
REMOVED TO ALLOW THE INSTALLATION OF THE NEW
WORK.
THE CONTRACTOR SHALL PERFORM THE WORK WITH A
MINIMUM OF INCONVENIENCE TO THE FACILITY AND SO AS
NOT TO INTERRUPT THE DAY TO DAY WORK OPERATIONS.
THE CONTRACTOR SHALL ENSURE SAFE PASSAGE OF
PERSONS AROUND AREAS OF CONSTRUCTION AND SHALL
CONDUCT OPERATIONS TO PREVENT DAMAGE OR HARM
TO THE FACILITIES AND PERSONNEL. COORDINATE ALL
OPERATIONS WITH THE POC.
CONTRACTOR SHALL PROMPTLY REPAIR DAMAGE CAUSED
DURING OPERATIONS WITH SIMILAR MATERIALS AND
WORKMANSHIP.
ALL REMOVED ITEMS, MATERIALS AND DEBRIS, UNLESS
OTHERWISE NOTED, SHALL BE REMOVED PROMPTLY FROM
THE SITE AND DISPOSED OF IN A LEGAL MANNER.
ALL PERSONNEL TO WEAR APPROPRIATE PERSONAL
PROTECTIVE EQUIPMENT (PPE) DURING CONSTRUCTION.
CONSTRUCTION SITE TO BE PROPERLY BARRICADED FROM
INCOMING VEHICULAR TRAFFIC.
CONSTRUCTION SITE TO BE PROPERLY SECURED FROM
INCOMING AND SURROUNDING PEDESTRIAN TRAFFIC.
CONTRACTOR SHALL UTILIZE "WET CUTTING" METHOD
WHEN CUTTING OR SAWING ANY AND ALL CONCRETE OR
ASPHALT MATERIAL TO MINIMIZE DUST AND SILICA
EXPOSURE TO SURROUNDING BUILDINGS AND
PERSONNEL.
PLEASE CONTACT THE SIERRA ARMY DEPOT BASE SAFETY
DIVISION PERSONNEL AT (530) 827-5282 FOR ANY SAFETY
QUESTIONS, SAFETY CONCERNS, UNSAFE CONDITIONS OR
ACCIDENT REPORTING ISSUES.
K.P. KICK PLATE
L, LAV. LAVATORY
LAM. LAMINATED
L.C.B. LIQUID CHALK BOARD
LIN. LINEN
LG LONG
LT, LTG LIGHT, LIGHTING
L.W.A. LIGHT WEIGHT CONCRETE
L.W./W.R. LAVATORY W/ WASTE
RECEPTACLE
M.P. MEDICAL AIR
MATRL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MED MEDICINE
MFG'R MANUFACTURER
MIN MINIMUM, MINUTES
MSTL MILD STEEL
MT, MTD MOUNTED
MTL METAL
(N) NEW
N2O NITROUS OXIDE
N.I.A. NOT IN CONTRACT
N.T.S. NOT TO SCALE
O.H. OPPOSITE HAND
O2 OXYGEN
O.C. ON CENTER
O.F.C.I. OWNER FURNISH
CONTRACTOR INSTALL
O.F.O.I. OWNER FURNISH
OWNER INSTALL
OPNG OPENING
OPPO OPPOSITE
O.R. OPERATING ROOM
ORIG ORIGINAL
O/ OVER
PART. PARTITION
P.B. PANEL BOARD
P.C. PORTLAND CEMENT
P.D.S. PANEL DRIVEN STUDS
PERF PERFORATED
PL PLATE
PLAST. PLASTER
PLYWD PLYWOOD
P.T. PRESSURE TREATED
REF REFRIGERATOR
REINF REINFORCED
REQD REQUIRED
REV REVISED
RM. ROOM
RHMS ROUND HEAD MACHINE SCREW
RHWS ROUND HEAD WOOD SCREW
R.O. ROUGH OPENING
S SINK
S. DISP. SOAP DISPENSER
SCHED. SCHEDULE
SECT SECTION
SHT SHEET
SHVS SHELVES
SIM SIMILAR
S.M.S. SHEET METAL SCREW
SPEC'S SPECIFICATIONS
S.S. STAINLESS STEEL
ST. STL. STAINLESS STEEL
STFNR STIFFENER
STOR STORAGE
STRL STRUCTURAL
SUSP SUSPENDED
SW SWITCH
T & B TOP & BOTTOM
T & H THERMOSTAT / HUMIDISTAT
T.B. TACK BOARD
T.P.B. TELEPHONE PANEL BOARD
TEL TELEPHONE
TEM TEMPERED
TEMP. TEMPORARY
TERR. TERRAZZO
THK. THICK
T.O.S. TOP OF SLAB
TRK TRACK
TYP. TYPICAL
U/C UNDERCUT
U.O.N. UNLESS OTHERWISE NOTED
VAC VACUUM
VAV VARIABLE AIR VOLUME
V.C.T. VINYL COMPOSITE TILE
VERT VERTICAL
V.P. VISION PANEL
V.W.F. VINYL WALL FABRIC
W WIDTH
W/ WITH
W/C WHEEL CHAIR
W/O WITHOUT
W.C. WATER CLOSET
WD WOOD
WIN. WINDOW
W.G. WIRE GLASS
W.M. WIRE MESH
W.O. WHERE OCCURS
W.R. WATER RESISTANT
WSCT WAINSCOT
W.S.O. WET STAND PIPE
WT WEIGHT
W.W.A. WELDED WIRE MESH
@ AT
Ø DIAMETER
L ANGLE
A.B. ANCHOR BOLT
ACOUST. ACOUSTICAL
A/C AIR CONDITIONING
ADJ. ADJUSTABLE
ALUM. ALUMINUM
A.P. ACCESS PANEL
ARCH. ARCHITECTURAL
ASSY. ASSEMBLY
BD BOARD
BLKG. BLOCKING
BM. BEAM
BET. BETWEEN
BOT. BOTTOM
CAB CABINET
CO2 CARBON DIOXIDE
C CENTER LINE
[, C CHANNEL
C.B. CHALKBOARD
COMM. COMMUNICATION
C.G. CORNER GUARD
CLG CEILING
CLR, CL CLEAR
C.O. CLEAR OPENING
COL COLUMN
CONC CONCRETE
COND CONDITION
CONN CONNECTION
CONT CONTINUOUS
C.O.R. CONTRACTING OFFICER'S
REPRESENTATIVE
C.F.C.I. CONTRACTOR FURNISH,
CONTRACTOR INSTALL
C/S CLINIC SINK
CSK COUNTERSINK
C.T. CERAMIC TILE
DBL DOUBLE
DET DETAIL
D.F. DOUGLAS FIR
DK. DECK
DIAG DIAGONAL
DIM DIMENSION
DISP DISPENSER
DN DOWN
DR DOOR
DRWG DRAWING
D.S. DOWNSPOUT
D.S.P. DRY STANDPIPE
(E), EXIST EXISTING
EA. EACH
E.J. EXPANSION JOINT
EL, ELEV ELEVATION
ELECT ELECTRICAL
E.P.B. ELECTRICAL PANEL BOARD
EQ EQUAL
EXH EXHAUST
EXP EXPANSION
EXT EXTERIOR
F.A. FIRE ALARM
F.C. FOOT CONTROL
F.D. FIRE DAMPER
FDN. FOUNDATION
F.E.A. FIRE EXTINGUISHER CABINET
F.H.C. FIRE HOSE CABINET
FHMS FLAT HEAD MACHINE SCREW
FHWS FLAT HEAD WOOD SCREW
FIN FINISH
F.F. FINISH FLOOR
FIX FIXTURE
FL, FLR FLOOR
FLASH FLASHING
FLUOR FLUORESCENT
F.O.A. FACE OF CONCRETE
F.O.F. FACE OF FINISH
F.O.M. FACE OF MASONRY
F.O.S. FACE OF STUDS
F.P. FIREPROOFING
F.R. FRAMING
F.R.A. FIRE RETARDANT TREAT
FTG. FOOTING
FURR FURRING
F.V. FIELD VERIFY
GA GAUGE
GALV GALVANIZED
G.I. GALVANIZED IRON
GL GLASS
GRL GRILL
GYP GYPSUM
GYPBD GYPSUM BOARD
HC HOLLOW CORE
HD HEAD
HDR HEADER
HDWD HARDWOOD
HDWR HARDWARE
HGR HANGER
HM HOLLOW METAL
HORIZ HORIZONTAL
HT HEIGHT
INSUL INSULATION
IPS IRON PIPE SIZE
INT INTERIOR
I.V. INTRAVENOUS
JAN. JANITOR
"A" St t h
S t
E
X T
"A" St
H V
A C
HVAC
H V
A C
HVAC
"B" St
SITE PLAN / NOTES1
SHT
CONTENTS
SECOND FLOOR
2 FIRST FLOOR
BATHROOM DETAIL
STAIRWAY DETAIL
SCALE: 1"=1'-0"
PLAN VIEW
S
I n i t i a l
S u b m i t t a l
R e v i s i o n
V e r s i o n
C o n c e p t u a l
VICINITY MAPABBREVIATIONSGENERAL NOTES
SYMBOLS & LEGEND SHEET INDEX
File details come from the government source that posted it. Updated .