SPECIFICATIONS
This requirement is for a modular, pre-manufactured structure. The designer has the liberty to slightly modify overall dimensions as long as the building shall “fit” inside the area to be designated.
The facility shall have two distinct functional areas: The Secure area and the Staff Only area.
SECURE AREA:
· 6 Meeting Rooms - min. 10’x10’
· 1 Phone Room - min. 10’x10’
· 1 STE/STU Room - min. 10’x10’
· 1 Control Room - min. 7’x10’
· 1 Listening Room - min. 6’x10’
· 1 Detainee Restroom – min. 6’x8’
· 1 Wide Corridor to allow for escorting non-compliant individuals – min 8’ wide, preferable 10’.
Physical and Visual separation between the two functional areas is preferred. Corridor should be accessible through double doors, interior and exterior.
STAFF ONLY AREA:
· 1 Break Room – min. 10’x12’. Can be left open into the adjacent corridor.
· 2 Public Restrooms 1M+1W – handicapped accessible (non-detainee)
· 1 Mechanical Room and Storage space – as required.
STRUCTURE: Any modular, pre-manufactured, temporary facility (5 years life-span ok), that can be easily transported, installed above ground and connected to existing on-site utilities. Provide necessary tie-down to resist destructive weather events.
WALLS: Insert batt-insulation inside all wall partitions, interior and exterior for sound absorption. No other standard sound transmission is specified.
DOORS: We recommend all doors be 3’-0”, solid core (exterior grade type), for spec simplicity and maximum sound buffering.
WINDOWS: The Secure area of this facility shall have no windows, except for the double entry doors which shall be provided with small tempered light panes to allow for visual awareness to the outside.
The Staff Only area may have windows as an option, but not necessary.
FLOORS: Vinyl Tile flooring, in tile or continuous, or a similar low maintenance flooring material. Floor structure and underflooring shall be structurally capable to permit installation of detainee restraints.
CEILINGS: A solid ceiling material. No acoustical tile grid.
CORRIDORS: Both leaves of the 6’ double door between Secure Corridor and the Staff Only Corridor shall swing in both directions. Exterior 6’ double doors shall be provided with small lite panes.
EXTERIOR ACCESS: Entryways shall be accessible by wheelchair and each be provided with wood deck platforms and min. 4’ wide ramps to the ground. Exterior doors may be provided with a trough type rain diverter above the full opening for added protection.
EXTERIOR SHIELD: Per manufacturer’s specifications.
LIGHTING: Fixtures, Conduits and other Equipment shall be surface mounted. There shall be no in-wall conduit.
SECURITY CAMERAS: Shall be placed in each one of the 6 Meeting Rooms and the 2 Secure Meeting Rooms, as indicated on the drawing submitted with this WIB Request, as follows:
· In each room, the security cameras shall be located on the wall opposite from the front door, high up close to the ceiling as possible for full visibility behind the door at half-open.
· The Corridor shall be provided with ceiling mounted “dome” security cameras, as indicated on the drawing.
· Security cameras shall be powered through the transmission cable directly connected to the unit (not by plug and outlet) AIR CONDITIONING: Ventilation and conditioning should be provided by thru-the-wall pre-packaged units, as required. Return air, when needed and other ceiling and wall penetrations should be no more than absolutely necessary.
ELECTRIC & PHONE: All conduits, fixtures, light switches, electric outlets, junction boxes, and phone outlets shall be surface mounted. Install at standard height above floor, except where indicated otherwise (also see floor plan drawing):
· All 8 LEGAL MEETING ROOMS: Junction Boxes, Phone Outlets and Duplex electric outlets shall be mounted at +60” Above Finished Floor (5’ AFF).
· All 8 LEGAL MEETING ROOMS shall be provided with just one duplex outlet each, one light fixture, and one emergency light.
· STU/STE & PHONE ROOMS shall be provided with one phone outlet each installed at +5’AFF.
· CONTROL ROOM shall be equipped with 4 duplex outlets minimum and 1 phone outlet. A switch bank to control electric power and lighting of Legal Meeting rooms, STU, Phone rooms and of the Detainee Restroom shall be located here.
· All light fixtures shall be encased (sealed), surface mount ceiling type fixtures.
· CONTROL and LISTENING ROOMS shall be provided with 4 duplex electric outlets and 2 phone lines each.
· Break Room shall have 2 duplex outlets, countertop cabinets, refrigerator, microwave, and sink.
· Men and Women Restrooms shall be wheelchair accessible, with duplex GFI outlets at each.
ADDITIONAL ELECTRICAL SPECS FROM JDG:
· Each cat 5/6 drop will have 1 box with 2 cat 5/6 lines and 2 Phone lines
· Each fiber drop will have 1 box with 2 fiber lines
· Each cat 5/6 and fiber box will need to have a lock box cover
· Standard electrical outlets with 2 per room in all meeting rooms and phone rooms.
· Control room will need 4 electrical outlets
· Communications closet will need a 30amp dedicated outlet and a 20 amp dedicated outlet along with 2 standard electrical outlets
· Communications closet will need a temperature control system
· Communications closet will need a ground plate
· Fiber conduit will need to be Rigid conduit
· Cat 5/6 conduit can be EMT conduit
· Cat 5/6 conduit will run below fiber conduit
SPACE REQUIREMENTS
| Room |
| Duplex Outlet |
| Emergency Light |
| Phone |
| Security Camera |
| Remarks |
| 6 Meeting Rooms |
| 1 |
| 1 |
| na |
| 1 |
| +60”AFF outlets |
| STU/STE Room |
| 1 |
| 1 |
| 1 |
| 1 |
| +60”AFF outlets |
| Phone Room |
| 1 |
| 1 |
| 1 |
| 1 |
| +60”AFF outlets |
| Control Room |
| 4 |
| 1 |
| 1 |
| na |
| Light Switch Bank |
| Comms |
| 4 |
| 1 |
| na |
| na |
| Listening Room |
| 4 |
| 1 |
| 1 |
| na |
| Detainee R/R |
| na |
| 1 |
| na |
| 1 |
| Control Corridor |
| 2 |
| 2 |
| na |
| 2 |
| Ceiling dome security |
| Staff Only Corridor |
| 2 |
| 1 |
| na |
| 1 |
| Ceiling dome security |
| Break Room |
| 2 |
| 1 |
| na |
| na |
| 1GFI |
| Men R/R |
| 1 |
| 1 |
| na |
| na |
| 1GFI |
| Women R/R |
| 1 |
| 1 |
| na |
| na |
| 1GFI |
| Storage / Janitor |
| 1 |
| 1 |
| na |
| na |
| Mechanical |
| ar |
| ar |
| na |
| na |
| As required |
UTILITIES: Electric, Waste and Electric service shall be extended from the Existing Echo Block building, which is located approx. 50’ away from this project location.
SITE IMPROVEMENTS: 4’ wide concrete sidewalk shall be provided for access to this facility. The sidewalk shall provide a continuous path of wheeled accessibility from the nearest existing sidewalk by the Sally-Port to both access ramps to the entry doors to this project.