T20W163-320-050 AC Electrical Distribution Schematic (Rev-).pdf

PDF 981 KB Posted

Attached to
OVERHAUL SURVEYBOAT SPIES
Solicitation number
W912BU20R0057
Issued by

View the file

Other files

File Type Posted
UPDATED-SPIES SECTB.doc DOC document
AMENDMENT 0003 - 20-R-0057-0003.pdf PDF
SF30- 20R0057- P00002.pdf PDF
SF-30 - AMENDMENT 0001 - OVERHAUL SURVEYBOAT SPIES.pdf PDF
T20W163-850-002 HR SPIES Docking Diagram.pdf PDF
T20W163-320-030 12-24VDC Alarm Panel (Rev-).pdf PDF
SPIES SECT M-SOW.doc DOC document
SPIES SECT C- SOW.docx DOCX document
SPIES SECT B-SOW .doc DOC document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EQUIPMENT PARTS LIST FOR DRAWING T25F145-320-050 120/240 VAC 1 ɸ DISTRIBUTION

DESRIPTION

PART # (Vendor / Maker) Quantity

SPI-1

SHORE POWER INLET W/ENCLOSURE

125/250 VAC 50 AMP

MARINCO 6353EL-B 2

T-1 12KVA ISOLATION TRANSFORMER 240v 50 AMP CHARLES INDUSTRIES 93-IXFMR12I-A 2

LT-1

LED LIGHT 4" ROUND (BLACK)

12W (0.1 Amp @ 120VAC)

LOTUS # LY41RCD (BLACK)

LT-2

LED LIGHT 4" ROUND (WHITE)

12W (0.1 Amp @ 120VAC)

LOTUS # LY41RCD (WHITE)

VF-1

VENTILATION FAN (0.17 AMP @ 115VAC)

FANTEC FR 100

GE-1

REFRIGERATOR/FREEZER 12.2 CUBIC FEET

( AMP @ 120VAC)

HAIER # HRF12WNDWW 1

GE-2

MICROWAVE (AMP @ 120VAC)

AVANTI # MO7082MB BLACK 1

OZ-1 OZONE GENERATOR

HEADHUNTER # 0Z-1(115)

PFW-1

Fresh Water Pump Headhunter Sing Ray / SR-115/60

OD-1 DUPLEX OUTLET 15 AMP

COOPER WIRING DEVICES SERIES #6252_

OD-2 DUPLEX OUTLET 20 AMP

COOPER WIRING DEVICES SERIES #6352_

ODG-1 GFCI OUTLET 15 AMP

COOPER WIRING DEVICES SERIES #VGF15_

ODG-2 GFCI OUTLET 20 AMP

COOPER WIRING DEVICES SERIES #VGF20_

AF-1

Delta T 11" SMALL AXIAL FAN

(0.67 AMP @ 120VAC)

11" AXIAL FANS / 500-211115 4

AFR-1 DOUBLE POLE ICE CUBE RELAY WITH BASE

RELAY,8 PIN OCT,DPDT,24V COIL

MCMASTER CARR, 7580T43

HW-1

HOT WATER TANK 11 GALLON

( 6.9 AMP @ 220 VAC)

KUUMA 1

MSD-1

LINEAR AIR PUMP (MSD SYSTEM)

( 0.8 AMP @ 120 VAC)

HURRICANE MODEL AP-60L 1

NOTE:

1) SYSTEM DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH USCG REGULATIONS 46 CFR 183

2) ALL CABLES ARE SIZED PER 46 CFR 183.340 (P) EXCEPT FOR CONTROL CIRCUITS 46 CFR 183.340 (C)

3) ALL CABLE SIZES ARE AWG.

4) MAIN ENGINE START MAXIMUM ALLOWABLE CIRCUIT RESISTANCE IS 0.002 OHMS. 4/0 CABLE = 0.053

OHMS PER 1000 FT. 10 CONNECTIONS PER CIRCUIT @ 0.00001 OHM EACH. 35' MAXIMUM ALLOWABLE

TOTAL CABLE LENGTH OF 4/0 CABLE PER CIRCUIT.

EQUIPMENT PARTS LIST FOR DRAWING T25F145-320-050 120/240 VAC 1 ɸ DISTRIBUTION MAIN SWITCHBOARD (CONTINUED)

Part # DESRIPTION

PART # (Vendor / Maker) Quantity

HVC-1

CENTRIFUGAL WATER PUMP 38GPM

( 4.5 AMP @ 230 VAC) [CIRCULATING PUMP]

TECHNICOLD # TE2000 1

HVC-2

CENTRIFUGAL WATER PUMP 16GPM

( 3 AMP @ 230 VAC) [SEAWATER PUMP]

TECHNICOLD # TE1000B 2

HVC-3

AIR HANDLER 2400 BTU / 2.5KW HEAT STRIP

(3.2 AMP @ 230 VAC / 10.8 AMP @ 230 VAC)

TECHNICOLD # RA24HB 2

HVC-4

AIR HANDLER 1800 BTU / 1KW HEAT STRIP

(3.55 AMP @ 230 VAC / 4.34 AMP @ 230 VAC)

TECHNICOLD # RAVC18HB 2

HVC-5

AIR HANDLER 1800 BTU / 2KW HEAT STRIP

(3.55 AMP @ 230 VAC / 8.7 AMP @ 230 VAC)

TECHNICOLD # RA18HB 2

HVC-6

AIR HANDLER 1600 BTU / 2KW HEAT STRIP

(3.55 AMP @ 230 VAC / 8.7 AMP @ 230 VAC)

TECHNICOLD # RA16HB 2

HVC-7

CHILLER ASSEMBLY 60,000 BTU/HR / 5 TON WITH

EASY START (5.51 AMP @ 230 VAC)

TECHNICOLD # DW60B-ES 2

NOTE:

WIRE COLOR ABBREVIATION DEFINITIONS

COLORS MAY BE TAPE:

BK - BLACK

BL - BLUE

R - RED

G - GREEN

W - WHITE

SH - SHIELD

REV DATE DESCRIPTION INT CHECKED

-- 04/18/2018 Issued for Submittal GBC JDS

PROJECT:

TITLE:

STATUS:

APPROVAL TEKNICRAFT:

PLOT SIZE:SCALE: REV: DRAWING No: HULL No:

US COAST GUARD

TD20-46AA

Rev.

US Coast Guard

N/A

(Sheet 1 of 8)

120/240 VAC 1 Phase Dist. - Parts List & Notes

L1

N L2

G

L1 X

Y

ZGR

L2

G

AC PANEL BUSS CONTINUED

ON SHEET 3

PORT GENERATOR

NORTHERN LIGHTS

C40M.3

120/240 1ὲ 40KW

120/240 VAC 1ɸ

SWITCHBOARD BUSS

L1 L2 N G

#2 Shore Power

L1 L2 N G

L1 L2 N G

L1 L2 N G

TO HVAC PANEL CONTINUED

ON SHEET 7

6/4

6/4

1/4

1/4

Interlocked to allow one source

Interlocked to allow one source

To Single Point Ground See Dwg T20W163-320-010 Sh 44/0

B1

B1

B2

B2

B2

IT1

L1

N L2

G

L1 X

Y

ZGR

L2

G

IT1

#1 Shore Power

STBD GENERATOR

NORTHERN LIGHTS

C40M.3

120/240 1ὲ 40KW

PROJECT:

TITLE:

STATUS:

APPROVAL TEKNICRAFT:

PLOT SIZE:SCALE: REV: DRAWING No: HULL No:

US COAST GUARD

TD20-46AA

Rev.

US Coast Guard

N/A

(Sheet 2 of 8)

120/240 VAC 1 Phase Distribution

L1 L2 N G

10/3

UPPER SURVEY OUTLETS

15 AMP BK

W G

12/3

10 AMP R

W G

12/3

PILOT HOUSE RECEPTICALS

20 AMP BK

W G

12/3

EXTERIOR RECEPTICALS

20 AMP R

W G

12/3

CABIN OUTLETS

20 AMP BK

W G

12/3

BELOW DECKS OUTLETS

20 AMP R

W G

12/3

HEAD/BERTH OUTLETS & FAN

15 AMP BK

W G

12/3

GALLEY OUTLETS & FAN

4 AMP R

W G

14/3

BK

W G

12/3

12 AMP

R W G

12/3

REFRIGERATOR

12 AMP

BK

W G

12/3

MICROWAVE R

W G

AC PANEL CONTINUED FROM

SHEET 2

BK

W G

MAIN SURVEY

RACK UPS

BK

W G

PROCESSING

COMPUTER

RACK

BK

W G

BK

W G

PORT BELOW DECK

BK

W G

STBD BELOW DECK

PILOT HOUSE

BK

W G

BERTH

BK

W G

BK

W G

HEAD

BK

W G

BK

W G

GALLEY

HEAD

GALLEY

VF-1

VF-1

BK

W G

BK

W G

REFRIGERATOR

MICROWAVE

TEST

RESET

BK

W G

TEST

RESET

PORT ENGINE ROOM

TEST

RESET

BK

W G

TEST

RESET

STBD ENGINE ROOM

OD-2 OD-2 OD-2

OD-2OD-2OD-2OD-2

OD-2

OD-2OD-2OD-2

OD-2ODG-2

ODG-2

ODG-2ODG-2

ODG-2ODG-2

OD-2

OD-2

LOWER SURVEY OUTLETS

PORT ENGINE ROOM OUTLETS

20 AMP

STBD ENGINE ROOM OUTLETS

20 AMP

OD-2

TEST

RESET

TEST

RESET

OD-2ODG-2

TEST

RESET

BK

W G

STBD CABIN

OD-2

OD-2OD-2OD-2 OD-2

BK

W G

PORT CABIN

OD-2

OD-2OD-2OD-2 OD-2

BK

W G

OD-2

BK

W G

OD-2

BK

W G

OD-2

AFT DECK FWD DECK

TOP DECK

BK

W G

PORT

OD-2OD-2

PROJECT:

TITLE:

STATUS:

APPROVAL TEKNICRAFT:

PLOT SIZE:SCALE: REV: DRAWING No: HULL No:

US COAST GUARD

TD20-46AA

Rev.

US Coast Guard

N/A

(Sheet 3 of 8)

14/3

BK

W G

14/3

R W G

14/3

BK

W G

X

14/3

HOUSE BATTERY CHARGER #1

12V 65 AMP

14 AMP BK

G

R

G 14/3

HOUSE BATTERY CHARGER #2

12V 65 AMP

14 AMP

12/3

16 AMP BK

W G

12/3

16 AMP R

W G

PORT ENGINE BATTERY CHARGER

24V 45 AMP

STBD ENGINE BATTERY CHARGER

24V 45 AMP

14/3

5 AMP BK

W G

14/3

5 AMP R

W G

PORT GENERATOR BATTERY

CHARGER 12V 20 AMP

STBD GENERATOR BATTERY

CHARGER 12V 20 AMP

MSD BLOWER

4 AMP

LT-1 LT-1LT-1LT-1LT-1LT-1

R W G

BK

R W G

BK

14/4

BK

W G

PILOT HOUSE

LT-2

BK

W G

LT-2

HEAD

0.2 AMP

LT-2 LT-2LT-2LT-2LT-2LT-2

R W G

BK

R W G

BK

14/4

BK

W G

MAIN CABIN

LT-2LT-2LT-2LT-2

1 AMP

0.6 AMP

OZONE

GENERATOR

-GREY WATER

OZ-1

OZONE

GENERATOR

-BLACK WATER

OZ-1

BK

W G

PFW-1

TO HOUSE BANK BATTERY CHARGER

SEE DRAWING #T20W163-320-010

BATTERY DISTRIBUTION - HOUSE SHEET 4 OF 4

TO HOUSE BANK BATTERY CHARGER

SEE DRAWING #T20W163-320-010

BATTERY DISTRIBUTION - HOUSE SHEET 4 OF 4

TO PORT ENGINE BANK BATTERY CHARGER

SEE DRAWING #T20W163-320-010

BATTERY DISTRIBUTION - HOUSE SHEET 2 OF 4

TO STBD ENGINE BANK BATTERY CHARGER

SEE DRAWING #T20W163-320-010

BATTERY DISTRIBUTION - HOUSE SHEET 3 OF 4

TO PORT GENERATOR BATTERY CHARGER

SEE DRAWING #T20W163-320-010

BATTERY DISTRIBUTION - HOUSE SHEET 2 OF 4

TO STBD GENERATOR BATTERY CHARGER

SEE DRAWING #T20W163-320-010

BATTERY DISTRIBUTION - HOUSE SHEET 3 OF 4

AHEAD MSD

LINEAR AIR PUMP

MSD-1

BK

W G

10 AMP

BELOW DECK LIGHTING

10 AMP

FRESH WATER PUMP

OZONE GENERATORS

GREY/BLACK WATER

2 AMP BK

W G

BK

W G

14/3

R W G

SPARE

BK

W G

LT-3

EQUIPMENT ROOM

0.2 AMP

LT-3

BK

W G

LT-3

STBD LAZZERETTE

0.2 AMP

LT-3

BK

W G

LT-3

STBD E/R

0.2 AMP

LT-3

LT-2

BK

W G

LT-2

GALLEY

0.2 AMP

LT-2

BK

W G

LT-2

BUNK ROOM

0.2 AMP

LT-3

BK

W G

LT-3

PORT LAZZERETTE

0.2 AMP

LT-3

BK

W G

LT-3

PORT E/R

0.2 AMP

LT-3

14/3

BK

W G

10 AMP

CABIN LIGHTING

W

W

PROJECT:

TITLE:

STATUS:

APPROVAL TEKNICRAFT:

PLOT SIZE:SCALE: REV: DRAWING No: HULL No:

US COAST GUARD

TD20-46AA

Rev.

US Coast Guard

N/A

(Sheet 4 of 8)

BK

R G

15 14/3

PORT ENGINE ROOM BILGE PUMP

(5HP)

15.2 AMP

BK

R G

15 14/3

15.2 AMP

STBD ENGINE ROOM BILGE PUMP

(5HP)

BK

R G

15 14/3

8 AMP

HOT WATER HEATER

ARID BILGE

SYSTEM -FWD

(6 POINT)

ARID BILGE

SYSTEM- AFT

(6 POINT)

BK

W G

SURVEY

WINCH

RECEPTACLE

BK

R G

MOTOR

STARTER/

DISCONNECT

BK

R G

BK

R G

BK

R G

START / STOP

PILOT HOUSE

START / STOP

LOCAL CONTROL

MOTOR

STARTER/

DISCONNECT

BK

R G

BK

R G

BK

R G

START / STOP

PILOT HOUSE

START / STOP

LOCAL CONTROL

HOT WATER

TANK

BK

R G

HW-1

14/3

ARID BILGE SYSTEMS

2 AMP R

W G

14/3

SURVEY WINCH (2HP VFD DRIVE)

10 AMP BK

R G

A-FRAME HPU

VOID FANS

14/3

11.7 AMP BK

R G

A-FRAME

HPU

BK

R G

4 AMP

14/3

BK

R G

BK

W G

FOREPEAK

BK

W G

LAZERETTE

VF-1

VF-1

0.17 AMP

0.17 AMP

STARTER/

DISCONNECT

BK

R G

BK

R G

SPARE

PROJECT:

TITLE:

STATUS:

APPROVAL TEKNICRAFT:

PLOT SIZE:SCALE: REV: DRAWING No: HULL No:

US COAST GUARD

TD20-46AA

Rev.

US Coast Guard

N/A

(Sheet 5 of 8)

PORT ENGINE ROOM EXHAUST FANS

4 AMP BK

W G

14/3

STBD ENGINE ROOM EXHAUST FANS

4 AMP R

W G

PORT MAIN ENGINE BLOCK HEATER

(1.5KW)

6.25 AMP

STBD MAIN ENGINE BLOCK HEATER

(1.5KW)

6.25 AMP

PORT GENERATOR BLOCK HEATER

(500W)

4.2 AMP

STBD GENERATOR BLOCK HEATER

(500W)

4.2 AMP

PORT ENGINE ROOM HEATER

15 AMP

BK

W G

BK

W G

BK

W G

BK

W G

14/3

14/3

AF-1

AF-1

PORT ENGINE ROOM

VENTILATION FANS

PORT FIREBOY CONTACT 16 & 17

SEE DRAWING #T20W163-320-030

ALARM PANEL DISTRIBUTION - FIREBOY

SHEET 3 OF 3

BK

W G

BK

W G

BK

W G

BK

W G

14/3

14/3

AF-1

AF-1

STBD ENGINE ROOM

VENTILATION FANS

STBD FIREBOY CONTACT 16 & 17

SEE DRAWING #T20W163-320-030

ALARM PANEL DISTRIBUTION - FIREBOY

SHEET 3 OF 3

BK

W G

BLOCK HEATER

BK

W G

BLOCK HEATER

OD-1

OD-1

BK

R G

20 12/3

PORT ENGINE ROOM

BASEBOARD HEATER

WITH BUILT IN

THREMOSTAT

BK

R G

BK

R G

PORT ENGINE ROOM HEATER

STBD ENGINE ROOM HEATER

14/3

BK

W G

14/3

BK

R G

14/3

BK

R G

14/3

R W G

14/3

BK

W G

PH WINDOW HEATERS

13.9 AMP

STBD ENGINE ROOM

BASEBOARD HEATER

WITH BUILT IN

THREMOSTAT

14/3

LAZARETTE HEATERS

12.5 AMP

G

15 THERMOSTAT

THERMOSTAT

R

BK

CAMERAS

HEATER

1500 W

HEATER

1500 W

PORT LAZ HEATER

STBD LAZ HEATER

BK

R G

BLOCK HEATERJ-BOX

BK

R G

BLOCK HEATERJ-BOX

14/3

15 AMP

G W

BK

BK

W G

UNDER DASH

OD-2OD-2

BK

W G

OD-2

FWD MAIN CABIN

TV

BK

W G

BK

W G

PILOT HOUSE

WINDOW HEATERS

PILOT HOUSE

WINDOW HEATERS

PILOT HOUSE

WINDOW HEATERS

PROJECT:

TITLE:

STATUS:

APPROVAL TEKNICRAFT:

PLOT SIZE:SCALE: REV: DRAWING No: HULL No:

US COAST GUARD

TD20-46AA

Rev.

US Coast Guard

N/A

(Sheet 6 of 8)

HELM FCU BLOWER RA24HB

3.2 AMP BK

R G

14/3

AMP BK

R G

14/3

PORT MAIN DECK AFT FCU BLOWER

RA18HB

10.05 AMP BK

R G

14/3

PORT ACCOM FCU BLOWER RA16HB

8.05 AMP BK

R G

BK

R G

BK

W G

BK

R G

10/3

CHILLER #1 CW60B-ES

16 AMP

14/3

RAW WATER PUMP #1

2 AMP

14/315

FAN COIL UNIT

24,000 BTU /

ELECTRIC HEAT

2.5KW

BK

R G

BK

R G

BK

R G

FAN COIL UNIT

18,000 BTU /

ELECTRIC HEAT

2KW

FAN COIL UNIT

16,000 BTU /

ELECTRIC HEAT

1KW

SOFT START /

DISCONNECT

BK

R G

BK

R G

BK

R G

AC CHILLER UNIT

60,000 BTU / HOUR

HVC-2BK

W G

HVC-5

HVC-3

HVC-7

WATER LOOP CIRCULATION PUMP

HVC-1BK

R G

3.8 AMP

STARTER/

DISCONNECT

BK

W G

BK

W G

STARTER/

DISCONNECT

BK

R G

BK

R G

FAN/ TEMP

CONTROL

FAN/ TEMP

CONTROL

FAN/ TEMP

CONTROL

L1 L2 N G

AC PANEL CONTINUED FROM

SHEET 2

OD-1BK

R G

SPARE

HVC-6

PROJECT:

TITLE:

STATUS:

APPROVAL TEKNICRAFT:

PLOT SIZE:SCALE: REV: DRAWING No: HULL No:

US COAST GUARD

TD20-46AA

Rev.

US Coast Guard

N/A

(Sheet 7 of 8)

MAIN DECK FWD FCU BLOWER

RAVC18HB

BK

R G

FAN COIL UNIT

18,000 BTU /

ELECTRIC HEAT

1KW

BK

R G

FAN COIL UNIT

24,000 BTU /

ELECTRIC HEAT

2.5KW

HVC-4

HVC-3

FAN/ TEMP

CONTROL

FAN/ TEMP

CONTROL

14/3

UPPER CABIN FCU BLOWER RA24HB

3.2 AMP BK

R G

14/3

BK

R G

14/3

STBD MAIN DECK AFT FCU BLOWER

RA18HB

10.05 AMP BK

R G

14/3

STBD ACCOM FCU BLOWER RA16HB

8.05 AMP BK

R G

BK

R G

BK

W G

10/3

CHILLER #2 CW60B-ES

16 AMP

14/3

RAW WATER PUMP #2

2 AMP

BK

R G

BK

R G

FAN COIL UNIT

18,000 BTU /

ELECTRIC HEAT

2KW

FAN COIL UNIT

16,000 BTU /

ELECTRIC HEAT

1KW

SOFT START /

DISCONNECT

BK

R G

BK

R G

BK

R G

AC CHILLER UNIT

60,000 BTU / HOUR

HVC-2BK

W G

HVC-5

HVC-7

STARTER/

DISCONNECT

BK

W G

BK

W G

FAN/ TEMP

CONTROL

FAN/ TEMP

CONTROL

FAN COIL UNIT

18,000 BTU /

ELECTRIC HEAT

1KW

BK

R G

HVC-4

HVC-6

PROJECT:

TITLE:

STATUS:

APPROVAL TEKNICRAFT:

PLOT SIZE:SCALE: REV: DRAWING No: HULL No:

US COAST GUARD

TD20-46AA

Rev.

US Coast Guard

N/A

(Sheet 8 of 8)