Amendment 4-Drawings.pdf

PDF 4 MB Posted

Attached to
MOTCO Access Control Point (ACP) Gate 1 Federal contract opportunity
Solicitation number
W9123821R0005
Issued by
Department of the Army Corps of Engineers Engineering District Sacramento

About this file

This notice provides information about an upcoming request for proposal for construction services. The project involves upgrading an access control point and gate for a military facility, including constructing a visitor control center, gate house, overwatch and guard booths, vehicle inspection canopies, roadways, parking, security and communications systems, and supporting site development. The estimated value is between $10-25 million. The solicitation is expected to be issued on October 28th with proposals due December 3rd. The NAICS code is 236220 and size standard is $39.5 million. The agency is the Department of the Army Corps of Engineers Engineering District Sacramento. Contractors should monitor the beta.sam.gov portal for any updates to the notice or interested vendors list.

View the file

Other files for this federal contract opportunity

Other files attached to MOTCO Access Control Point (ACP) Gate 1, newest first.
File Type Posted
Amendment 0005.pdf PDF
Amendment 5 - Technical Specifications.pdf PDF
Amendment 5 - Narrative of changes.pdf PDF
Amendment 5 - Drawings.pdf PDF
Amendment 4 - Narrative of Changes.pdf PDF
Amendment 4 -Technical Specifications.pdf PDF
Amendment 0004 - Posted revised specs and drawings and posted narrative of changes.pdf PDF
Amendment 0003 - Extend Due Date and Questions Period and Posted revised Specs.pdf PDF
W9123821R0005 Amendment 0003.pdf PDF
Amendment 3 -Specs. Section 34 71 13.9 11.24.20.pdf PDF
Amendment 3-Specifications- Section 34 71 13.19 11.24.20.pdf PDF
Amendment 0003.pdf PDF
Site visit pictures 11.17.20.pdf PDF
Site Visit Sign-in Sheet 11.17.20.pdf PDF
Amendment 0002.pdf PDF
Amendment 0002.pdf PDF
Amendment 1 - Drawings Electrical Site - 10.29.20.pdf PDF
Amendment 0001.pdf PDF
Amendment 1 - Specifications - 10.29.20.pdf PDF
Amendment 1 - Drawings - Access Control Point - 10.29.20.pdf PDF
Attachment 2 Drawings-Access Control Point.pdf PDF
Attachment 6 Past Performance Questionnaire.pdf PDF
Attachment 1 Specifications.pdf PDF
Attachment 5 Pre-Award Survey.pdf PDF
Attachment 3 Drawings - Electrical Site.pdf PDF
Attachment 4 DB Wage Determination.pdf PDF
W9123821R0005.pdf PDF
Show all 27

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DIRT

.9

.5

A S

T R E E T

IH 16-19 C

N 2197646.862

E 6122490.720

ELEV 35.807

SS

A STREET

CO

W W

CO

CO

S

A N

CO

E

REMOVE TRAFFIC SIGNS (2)

RAMP

REMOVE HANDICAPPED

STRUCTURE

REMOVE MISC.

STRUCTURE

REMOVE MISC.

(TYP) AND ASPAHLT PAVEMENT

REMOVE CURB AND GUTTER

SIDEWALK

REMOVE CONC.

GAS LINE SIZE IS 3/4" PER BASE MX

ACTIVE BARRIER CONSTRUCTION

NECESSARY TO ACCOMODATE

RELOCATE GAS LINE AS

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

S A

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

S A

C R

A M

E N

T O

C A

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

®of Engineers

US Army Corps

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

O M

A H

A D

IS

T R

IC

T

M

IL

IT

A R

Y O

C E

A N T

E R

M

IN

A L

C O

N C

O R

D

P N

A C

C E

S S C

O N

T R

O L P

O

IN

T

G A

T E

ADVERTISEMENT

N 2,197,763.01

E 6,122,624.12

N 2,197,760.54

E 6,122,628.51

N 2,197,659.82

E 6,122,535.86

N 2,197,663.36

E 6,122,532.26

PBX

P B

PBX

PBX

P B X

P B X

P B X

P B

X

P B X

PBX

PBX

PBX

PBX

P B

P B

PB

PBX

PBX

P B

PB

P B

P B

P B

P B

P B

P B

PB

PB

PBX

PBX

PBX

2 31

4 5 6

PIV

KEYPLAN SCALE: 1" =200'-0"

N

S I

D

F

IL

E N

U M

B E

R

F

IL

E N

A M

E

CD103

C A

C D

.d g n

A R

E A

20'010'20'

SCALE: 1" = 20'-0"

D E

M O

L

IT

IO

N P

L A

N

/2

/2

W .C D

A V

E N

P O

R T

A F

A N

C

IU

L L

O

A F

A N

C

IU

L L

O

W .C D

A V

E N

P O

R T

SITE DEMOLITION PLANS.

SEE SHEETS ED100 THROUGH ED105 FOR ELECTRICAL AND COMMUNICATION

ELECTRICAL AND COMMUNICATION DEMOLITION IS NOT SHOWN ON THIS SHEET.1)

GENERAL NOTE:

F -5

-0

W -2

-R -0

A

M G

A S L

IN

E N

O T

E

/3 /2

GAS STUB

S

T R E E T

A STREET

STAIRS

BOLLARDS (TYP.)

AND LIGHTS (TYP.)

TRAFFIC SIGNS

STOP CONTROL

& GUTTER (TYP)

CONCRETE CURB

& GUTTER (TYP)

CONCRETE CURB

BARRIER (POST/CABLE/)

CABLE BASED PASSIVE VEHICLE

BARRIER (TYP)

ACTIVE VEHICLE

PAVEMENT ELEVATION

TIE INTO EXISTING

RAMP "B"

HANDICAP

(POST/CABLE/)

VEHICLE BARRIER

CABLE BASED PASSIVE

SIDEWALK (TYP)

6' CONCRETE

PASSIVE VEHICLE BARRIER

VEHICLE BARRIER AND

BETWEEN EDGE OF ACTIVE

3.3' MAXIMUM GAP

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

S A

C R

A M

E N

T O

C A

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

®of Engineers

US Army Corps

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

O M

A H

A D

IS

T R

IC

T

M

IL

IT

A R

Y O

C E

A N T

E R

M

IN

A L

C O

N C

O R

D

P N

A C

C E

S S C

O N

T R

O L P

O

IN

T

G A

T E

ADVERTISEMENT

P B

P B

P B

S T A

.5 6 P

T

S T A

.3

P O

E

N 2,197,712.85

E 6,122,601.17

N 2,197,676.63

E 6,122,586.75

N 2,197,705.15

E 6,122,556.15

N 2,197,698.40

E 6,122,550.97

N 2,197,686.11

E 6,122,541.54

N 2,197,690.23

E 6,122,530.41

N 2,197,748.30

E 6,122,493.33

N 2,197,760.54

E 6,122,628.51

N 2,197,717.84

E 6,122,604.50

N 2,197,659.82

E 6,122,535.86

N 2,197,663.36

E 6,122,532.26

N 2,197,675.29

E 6,122,550.49

N 2,197,762.70

E 6,122,624.67

N 2,197,767.74

E 6,122,508.24

N 2,197,744.94

E 6,122,537.96

PBX

P B

PBX

PBX

P B X

P B X

P B X

P B

X

P B X

PBX

PBX

PBX

PBX

P B

P B

PB

PBX

PBX

P B

PB

P B

P B

P B

P B

P B

P B

PB

PB

PBX

PBX

PBX

2 31

4 5 6

PIV

E N

A M

E

C

C S .d g n

E N

A

20'010'20'

SCALE: 1" = 20'-0"

IL

E N

U M

B E

R F

IL

E N

U M

B E

R

CS103

S

IT

E P

L A

N

A F

A N

C

IU

L L

O

A F

A N

C

IU

L L

O

W .C

D A

V E

N P

O R

T

A R

E A

BARRIER (POST/CABLE/FENCE)

CABLE BASED PASSIVE VEHICLE

LEGEND:

PBX

PB

BARRIER (POST/CABLE)

CABLE BASED PASSIVE VEHICLE

W .C

D A

V E

N P

O R

T

A N

S I

D

/2

/2

F -5

-0

F -5

-0

W -2

-R -0

W -2

-R -0

A

M P

A S

S

IV

E /A

C T

IV

E V

E H

IC

L E B

A R

R

IE

R N

O T

E

/4 /2

8"

3'-0"

WHEEL STOP

GROUT HOLE FULL

OPENING

DRAINAGE

INTO THE SURFACING

BY AN APPROVED METHOD, OR DRIVEN

SURFACE WITH A TIGHT FIT OBTAINED

IN A HOLE DRILLED IN THE FINISHED

BE PLACED PRIOR TO SURFACING OR

1/2" STD PIPE OR 3/4" REINF. ROD SHALL

CLEARANCE

1/2" MAX.

'-1

/4

5'-0 1/2"

1'-5 1/2"

4'-10 1/8"

STEEL LOOP RACK

2-3/8 OD TUBULAR

BIKE RACK COLOR.

& ANCHOR BOLTS TO MATCH

WRITTEN INSTRUCTIONS; PLATE

BOLTS PER MANUFACTURER'S

INTO CONC WITH 1/2" ANCHOR

WELDED TO LOOP RACK; SET

SURFACE MOUNTED PLATE;

CONC WALK

OR 3/4" DIAM. REINF. ROD

HOLE FOR 1/2" STD. PIPE

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

S A

C R

A M

E N

T O

C A

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

®of Engineers

US Army Corps

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

O M

A H

A D

IS

T R

IC

T

M

IL

IT

A R

Y O

C E

A N T

E R

M

IN

A L

C O

N C

O R

D

P N

A C

C E

S S C

O N

T R

O L P

O

IN

T

G A

T E

ADVERTISEMENT

T Y

P

TYP

VAULT

EXISTING COMMUNICATION

#4 @ 6" O.C. E.W.

#8 @ 6" O.C. E.W.

SECTION 2

PLAN

3 ADDITIONAL #8 BARS

COMMUNICATION VAULT CONCRETE SLAB

NO SCALE

NO SCALE

VAULT BELOW

EXISTING COMMUNICATIONS

S

E N

U M

B E

R

F

IL

E N

A M

E

C A

C S .d g n0 /2

/2

F

A N

C

IU

L L

O

A F

A N

C

IU

L L

O

W .C D

A V

E N

P O

R T

W .C D

A V

E N

P O

R T

INSTALLATION PLAN

NO SCALE

PRECAST CONCRETE WHEEL STOP DETAILS

ELEVATION

PLAN

L PARKING STALLC

PARKING STALL

2'-0" TO EDGE OF

BY THE SPECIFICATIONS

THE DRAWINGS OR REQUIRED

PAINTED STRIPES IF SHOWN ON

END VIEWS

8"

(MIN.)

2" 4"

SECTION 1

NOTE:

7'-0" (MIN.)

8'-0" (MAX)

1'-0"2'-0" (MIN.)1'-0" 2'-0" (MIN.) 1'-0"

"2

"2

(M

IN

"2

2 - #32 - #3

" TOOLED EDGE (TYP.)8

CENTER TO CENTER

NO SCALE

BIKE RACK DETAIL

SPECIFICATIONS.

2. INSTALL ACCORDING TO MANUFACTURER'S WRITTEN

GOVERNMENT APPROVAL.

BE SUBSTITUED WITH AN EQUAL PRODUCT WITH WRITTEN

COAT. TYPE: "PUBLICOAT" V.S. BRONZE. PRODUCT MAY

STD SURFACE MOUNT; COLOR AND FINISH: POWDER

STANLEY, INC. 1-800-368-2573, PRAIRIE SERIES BK-3,

1. BASIS OF DESIGN PRODUCT BIKE RACK: BY VICTOR

BIKE RACK NOTES:

CS503

-5

-0

M

IS

C S

IT

E D

E T

A

IL

S

W -2

-R -0

SLAB

PAVING OR

JOINT FILLER

BITUMINOUS

AROUND BOLLARD

CONCRETE FILL

2'-0" SQUARE

ROUND OR 2'-0"X

MINIMUM 2'-4" DIA

GALVANIZED AFTER FABRICATION

AND SHALL BE HOT DIPPED

FABRICATIONS OF THE SPECS

MISCELLANEOUS METAL

CONFORM TO SECTION 05 50 13

YELLOW. STEEL PIPE SHALL

STEEL PIPE PAINTED SAFETY

NPS 12 STANDARD WEIGHT

AS SHOWN

AND DOME AT TOP

FILL PIPE W/ CONC

AROUND

CONCRETE ALL

BOLLARD SLOPE

FOR EXTERIOR

NO SCALE

BOLLARD DETAIL

EQ EQ

M

IN

V A

R

IE

S

SHOWN ARE ACCEPTABLE.

SECTIONS, HOLES, AND DRAINAGE OPENINGS

STANDARD PRODUCT FROM THE CROSS

MINOR DEVIATIONS OF A MANUFACTURER'S

A

M B

O L L

A R

D D

E T

A

IL

/3 /2

VARIES PER PLAN

6'-0" 6'-0"

M

IN

V A

R

IE

S P

E R

VARIES PER PLAN

1'-6"

V A

R

IE

S P

E R

M

IN

M

IN

UNIT PAVERS

TRUNCATED DOME

4" X 8" NOMINAL

UNIT PAVERS

TRUNCATED DOME

4" X 8" NOMINAL

BACK OF CURB

FACE OF CURB

CONC GUTTER

PER DETAIL BELOW

INTERSECTING WITH ARCED CURB

CURB CUT RAMP; MODIFY WHEN

EJ (TYP)

EJ (TYP)

UNIT PAVERS

TRUNCATED DOME

4" X 8" NOMINAL

LINE

HINGE

LINE

HINGE

BACK OF CURB

FACE OF CURB

CONC GUTTER

EJ (TYP)

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

S A

C R

A M

E N

T O

C A

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

®of Engineers

US Army Corps

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

O M

A H

A D

IS

T R

IC

T

M

IL

IT

A R

Y O

C E

A N T

E R

M

IN

A L

C O

N C

O R

D

P N

A C

C E

S S C

O N

T R

O L P

O

IN

T

G A

T E

ADVERTISEMENT

S

E N

U M

B E

R

F

IL

E N

A M

E

C A

C S .d

H

N D

IC

A P R

A M

P D

E T

A

IL

S

:1 M

A X

:1 M

A X

12:1 M A X

:1 M

A X

:1 M

A X

M

IN

A R

C R

A D

IU

S

PLAN - ARCED CURB

PLAN - STRAIGHT CURB

1/2" = 1'-0"

1/2" = 1'-0"

ENLARGEMENT PLAN - CURB CUT RAMP "A"

ENLARGEMENT PLAN - CURB CUT RAMP "B"

C S

CS508

CS508

CS508

CS508

CS508

CS508

C S

C S

8 SIZE WHEN CUT

LESS THAN 1/2 NOMINAL

NO PAVERS SHALL BE

/2

/2

.C D

A V

E N

P O

R T

A F

A N

C

IU

L L

O

A F

A N

C

IU

L L

O

W .C D

A V

E N

P O

R T

CS506

F -5

-0

M

IL

IT

A R

Y O

C E

A N T

E R

M

IN

A L

C O

N C

O R

D

A C

C E

S S C

O N

T R

O L P

O

IN

T

G A

T E

P N

W -2

-R -0

NOTES:

RAMP DETAILS CAN BE FOUND ON CS507

ONLY USED FOR HANDICAP RAMPS. HANDICAP

1. UNIT PAVERS DEPICTED ON THIS PAGE ARE

A M N

O T

E A

D D

IT

IO

N /4 /2

CONC. CURB & GUTTER

CONTRACTION JOINT (TYP.)

EXPANSION JOINT (TYP.)

EXP. JT.

4" CONCRETE

1/8" R.

1/8" R.1/8" R.

JOINT SEALANT

BACKER ROD

JOINT FILLER

NON-EXTRUDING

PREFORMED

6" SUBBASE COURSE

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

S A

C R

A M

E N

T O

C A

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

®of Engineers

US Army Corps

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

O M

A H

A D

IS

T R

IC

T

M

IL

IT

A R

Y O

C E

A N T

E R

M

IN

A L

C O

N C

O R

D

P N

A C

C E

S S C

O N

T R

O L P

O

IN

T

G A

T E

E N

A M

E

C A

C S .d

CONTRACTION JOINT EXPANSION JOINT

SIDEWALK JOINT DETAILS

NO SCALE

NO SCALE

SINGLE-PURPOSE WALK

TYPICAL SECTION

NO SCALE

NOTES:

NOTES:

M

IN

W A

L K D

E P

T H

D E

P T

H

WALK WIDTH

12'

10'

8'

6'

4'

WIDTH

WALK

TRANSVERSE LONGITUDINAL

NOT REQUIRED

NOT REQUIRED

4'

5'

6'6'

5'

4'

6'

4'

CONTRACTION JOINT SPACING

JOINT SPACING FOR STRAIGHT RUNS

JOINT SPACING

40' MAX.

42' MAX.

40' MAX.

40' MAX.

42' MAX.

M

IN

TOOLEDSAWED

M

IN

SAWED

TYPICAL SIDEWALK JOINT LAYOUT PLAN

CURBS THAT ABUT THE SIDEWALK LONGITUDINALLY.

2. EXPANSION JOINTS SHALL NOT BE REQUIRED BETWEEN

CONCRETE CURB AND GUTTER.

THROUGH BOTH WALK AND CURB WHERE WALK ABUTS

1. TRANSVERSE EXPANSION JOINTS SHALL BE CONTINOUS

EXPANSION

" PER FOOT4

"8

" MIN.8

1 " MIN.8

"16

" MIN.8

"2

THE MANUFACTURER.

1. DEPTH OF SEALANT SHALL BE AS RECOMMENDED BY

/2

/2

W .C

D A

V E

N P

O R

T

A F

A N

C

IU

L L

O

A F

A N

C

IU

L L

O

W .C

D A

V E

N P

O R

T

A N

S I

D

F

IL

E N

U M

B E

R

CS508

S

ID

E W

A L

K J

O

IN

T D

E T

A

IL

S

F -5

-0

W -2

-R -0

A

M S

ID

E W

A L

K T

Y P

IC

A L N

O T

E /4 /2

3' 4'

VARIES 1.5' 1.5' VARIES

3'

4' VARIESVARIESVARIESVARIES

3'

4' VARIES 1.5' 2.5' 1.5' VARIES 1.5'

0.5'

6' 2' 3'

3'6'

VARIESVARIES

SIDEWALK

GUTTER

CURB AND

GUTTER

CURB AND

GUTTER

CURB AND

4'

6' 2' 3'

6" AGGREGATE BASE COURSE

6" SUBBASE COURSE

6" COMPACTED SUBGRADE (90%)

6" AGGREGATE BASE COURSE

6" SUBBASE COURSE

6" COMPACTED SUBGRADE (90%)

6" AGGREGATE BASE COURSE

6" SUBBASE COURSE

6" COMPACTED SUBGRADE (90%)

6" AGGREGATE BASE COURSE

8" P.C. CONCRETE PAVEMENT

6" COMPACTED SUBGRADE (90%)

6" AGGREGATE BASE COURSE

8" P.C. CONCRETE PAVEMENT

6" COMPACTED SUBGRADE (90%)

6" AGGREGATE BASE COURSE

8" P.C. CONCRETE PAVEMENT

6" COMPACTED SUBGRADE (90%)

6" AGGREGATE BASE COURSE

8" P.C. CONCRETE PAVEMENT

PAVED MEDIAN

CONCRETE

PAVED MEDIAN

CONCRETE

PAVED MEDIAN

CONCRETE

PAVED MEDIAN

CONCRETE

PAVED MEDIAN

CONCRETE

PAVEMENT

EDGE OF

PAVEMENT

EDGE OF

CURB

INTEGRAL

6" COMPACTED SUBGRADE (90%)

CURB

INTEGRAL

CURB

INTEGRAL

SIDEWALK

5' 5' 6'

CURB

INTEGRAL

CURB

INTEGRAL

2.5' 2.5'

GUTTER

CURB AND

6" AGGREGATE BASE COURSE

6" SUBBASE COURSE

6" COMPACTED SUBGRADE (90%)

4.5" HMA WEARING COURSE 4.5" HMA WEARING COURSE

4.5" HMA WEARING COURSE4.5" HMA WEARING COURSE

6" SUBBASE COURSE

6" SUBBASE COURSE

6" SUBBASE COURSE

6" SUBBASE COURSE

6" SUBBASE COURSE

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

S A

C R

A M

E N

T O

C A

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

®of Engineers

US Army Corps

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

O M

A H

A D

IS

T R

IC

T

M

IL

IT

A R

Y O

C E

A N T

E R

M

IN

A L

C O

N C

O R

D

P N

A C

C E

S S C

O N

T R

O L P

O

IN

T

G A

T E

ADVERTISEMENT

2%

2% 2%2% 2%

2%

5%

4:

3:1

2% 2%2% 2%2%

5%

4:

3:1

NO SCALE

NO SCALE

TYPICAL ROAD SECTION (CANOPY AREA)

2% 2% 2% 2% 2%

0% 0%

TYPICAL ROAD SECTION (APPROACH ZONE)

2%

2% 2%

2% 2%

2% 2%

2%

5%

5%

4:

4:1

3:1 3:1

2%

TO EXISTING

NO SCALE

TYPICAL ROAD SECTION (RESPONSE ZONE)

EXISTING

CONTINUES TO

3:1

4:1

5%

5%

4:1

3:1

2%

TO EXISTING

EXISTING

CONTINUES TO

EXIT ENTRANCE

EXIT

ENTRANCE ENTRANCE ENTRANCE

EXIT

ENTRANCE

% VARIES

EXISTING

CONTINUES TO

APPRX. STA 2+18 TO 3+00

APPRX. STA 3+40 TO 4+80

APPRX. STA 5+50 TO 8+60

S

E N

U M

B E

R

F

IL

E N

A M

E

/2

/2

.C D

A V

E N

P O

R T

A F

A N

C

IU

L L

O

A F

A N

C

IU

L L

O

W .C D

A V

E N

P O

R T

CG302

F -5

-0

C A

C G

.d g n

T Y

P

IC

A L R

O A

D S

E C

T

IO

N S

W -2

-R -0

A M M

E D

IA

N A

D D

IT

IO

N S

/4 /2

(P O

R T C

H

IC

A G

O H

IG

H W

A Y

SIDEWALK (TYP)

6' CONCRETE

EXISTING VCC PARKING LOT

2" MILL AND OVERLAY

LOCATED ABOVE

COORDINATE FOR THIS POINT IS

FOR 15'. SEE SHEET CP100

ASPHALT PAVEMENT CONTINUES

SIDEWALK (TYP)

6' CONCRETE

CONCRETE CURB AND GUTTER WHERE APPLICABLE

ASPHALT SHALL BE PLACED BETWEEN EXISTING

BETWEEN STATIONS 50+00 AND 52+09.23

ALL PAVEMENT PRIOR TO STATION 0+00 AND

MATCH EXISTING EDGE OF ROAD ELEVATIONS FOR

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

S A

C R

A M

E N

T O

C A

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

®of Engineers

US Army Corps

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

O M

A H

A D

IS

T R

IC

T

M

IL

IT

A R

Y O

C E

A N T

E R

M

IN

A L

C O

N C

O R

D

P N

A C

C E

S S C

O N

T R

O L P

O

IN

T

G A

T E

ADVERTISEMENT

PBX

P B

PBX

PBX

P B X

P B X

P B X

P B

X

P B X

PBX

PBX

PBX

PBX

P B

P B

PB

PBX

PBX

P B

PB

P B

P B

P B

P B

P B

P B

PB

PB

PBX

PBX

PBX

2 31

4 5 6

PIV

KEYPLAN SCALE: 1" =200'-0"

N

-1

N 2,197,779.92

E 6,121,627.57

N 2,197,636.49

E 6,121,678.19

N 2,197,627.41

E 6,121,681.39

N 2,197,584.76

E 6,121,696.44

N 2,197,572.94

E 6,121,700.61

N 2,197,550.04

E 6,121,715.38 N 2,197,550.07

E 6,121,721.39

N 2,197,671.03

E 6,121,666.00 N 2,197,667.38

E 6,121,667.29

N 2,197,525.99

E 6,121,955.59

N 2,197,499.41

E 6,122,038.89

E N

A M

E

C A

C P .d

NO SCALE

KEY PLAN

SEE SHEET CP301 FOR TYPICAL SECTION

AGGREGATE SURFACE SHOULDER

SEE SHEET CP301 FOR TYPICAL SECTION

CONCRETE HARDSTAND PAVEMENT

SEE SHEET CP301 FOR TYPICAL SECTION

ASPHALT PAVEMENT

LEGEND

/2

/2

P A

V

IN

G P

L A

N

W .C D

A V

E N

P O

R T

A F

A N

C

IU

L L

O

A F

A N

C

IU

L L

O

W .C D

A V

E N

P O

R T

A N

S I

D

F

IL

E N

U M

B E

R

CP101

A R

E A

N

20'010'20'

SCALE: 1" = 20'-0"

N

F -5

-0

W -2

-R -0

2" COLD MILL WITH 2" ASPHALT OVERLAY

A M G

E N

E R

A L N

O T

E /4 /2

SEE SHEETS CP301 AND CG302 FOR DETAILS

ALL NEWLY CONSTRUCTED MEDIANS ARE TO BE PAVED WITH 4" CONCRETE. 1)

GENERAL NOTE:

T R E E T

A S

T R E E T

INTEGRAL CURB (TYP)

SIDEWALK (TYP)

6' CONCRETE

CONCRETE CURB & GUTTER (TYP)

INTEGRAL CURB (TYP)

& GUTTER (TYP)

CONCRETE CURB

CURB (TYP)

INTEGRAL

& GUTTER (TYP)

CONCRETE CURB

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

S A

C R

A M

E N

T O

C A

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

®of Engineers

US Army Corps

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

O M

A H

A D

IS

T R

IC

T

M

IL

IT

A R

Y O

C E

A N T

E R

M

IN

A L

C O

N C

O R

D

P N

A C

C E

S S C

O N

T R

O L P

O

IN

T

G A

T E

ADVERTISEMENT

PBX

P B

PBX

PBX

P B X

P B X

P B X

P B

X

P B X

PBX

PBX

PBX

PBX

P B

P B

PB

PBX

PBX

P B

PB

P B

P B

P B

P B

P B

P B

PB

PB

PBX

PBX

PBX

2 31

4 5 6

PIV

KEYPLAN SCALE: 1" =200'-0"

N

GATEHOUSE

E N

A M

E

C A

C P .d

SEE SHEET CP301 FOR TYPICAL SECTION

AGGREGATE SURFACE SHOULDER

SEE SHEET CP301 FOR TYPICAL SECTION

CONCRETE HARDSTAND PAVEMENT

SEE SHEET CP301 FOR TYPICAL SECTION

ASPHALT PAVEMENT

LEGEND

/2

/2

P A

V

IN

G P

L A

N

W .C D

A V

E N

P O

R T

A F

A N

C

IU

L L

O

A F

A N

C

IU

L L

O

W .C D

A V

E N

P O

R T

A N

S I

D

F

IL

E N

U M

B E

R

CP102

A R

E A

2" ASPHALT PAVEMENT MILL AND OVERLAY

20'010'20'

SCALE: 1" = 20'-0"

N

F -5

-0

W -2

-R -0

SEE SHEETS CP301 AND CG302 FOR DETAILS

ALL NEWLY CONSTRUCTED MEDIANS ARE TO BE PAVED WITH 4" CONCRETE. 1)

GENERAL NOTE:

A

M G

E N

E R

A L N

O T

E /4 /2

T R E E T

A STREET

& GUTTER (TYP)

CONCRETE CURB

& GUTTER (TYP)

CONCRETE CURB

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

S A

C R

A M

E N

T O

C A

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

®of Engineers

US Army Corps

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

O M

A H

A D

IS

T R

IC

T

M

IL

IT

A R

Y O

C E

A N T

E R

M

IN

A L

C O

N C

O R

D

P N

A C

C E

S S C

O N

T R

O L P

O

IN

T

G A

T E

ADVERTISEMENT

PBX

P B

PBX

PBX

P B X

P B X

P B X

P B

X

P B X

PBX

PBX

PBX

PBX

P B

P B

PB

PBX

PBX

P B

PB

P B

P B

P B

P B

P B

P B

PB

PB

PBX

PBX

PBX

2 31

4 5 6

PIV

KEYPLAN SCALE: 1" =200'-0"

N

E N

A M

E

C A

C P .d

SEE SHEET CP301 FOR TYPICAL SECTION

AGGREGATE SURFACE SHOULDER

SEE SHEET CP301 FOR TYPICAL SECTION

CONCRETE HARDSTAND PAVEMENT

SEE SHEET CP301 FOR TYPICAL SECTION

ASPHALT PAVEMENT

LEGEND

/2

/2

P A

V

IN

G P

L A

N

W .C D

A V

E N

P O

R T

A F

A N

C

IU

L L

O

A F

A N

C

IU

L L

O

W .C D

A V

E N

P O

R T

A N

S I

D

F

IL

E N

U M

B E

R

CP103

A R

E A

2" ASPHALT PAVEMENT MILL AND OVERLAY

20'010'20'

SCALE: 1" = 20'-0"

N

F -5

-0

W -2

-R -0

SEE SHEETS CP301 AND CG302 FOR DETAILS

ALL NEWLY CONSTRUCTED MEDIANS ARE TO BE PAVED WITH 4" CONCRETE. 1)

GENERAL NOTE:

A

M G

E N

E R

A L N

O T

E /4 /2

CONCRETE CURB AND GUTTER

GEOTEXTILE

CONCRETE CURB AND GUTTER

GEOTEXTILE

THICKENED EDGE (TYP.)

GEOTEXTILE

GEOTEXTILE

GEOTEXTILE GEOTEXTILE

CONCRETE CURB AND GUTTER

FILL WITH BASE COURSEFILL WITH BASE COURSE

EXPANSION JOINT BETWEEN CONCRETE CURB AND GUTTER AND CONCRETE MEDIANEXPANSION JOINT BETWEEN CONCRETE CURB AND GUTTER AND CONCRETE MEDIAN

CONCRETE CURB AND GUTTER

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

S A

C R

A M

E N

T O

C A

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

®of Engineers

US Army Corps

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

O M

A H

A D

IS

T R

IC

T

M

IL

IT

A R

Y O

C E

A N T

E R

M

IN

A L

C O

N C

O R

D

P N

A C

C E

S S C

O N

T R

O L P

O

IN

T

G A

T E

S

E N

U M

B E

R

F

IL

E N

A M

E

CP301

C A

C P .d

T Y

P

IC

A L P

A V

E M

E N

T S

E C

T

IO

N S

6" SUBBASE COURSE

6" AGGREGATE BASE COURSE

6" COMPACTED SUBGRADE (90%)

1'-0"

NO SCALE

6" COMPACTED SUBGRADE (90%)

1'-0"

NO SCALE

TYPICAL P.C. CONCRETE PAVEMENT SECTION

5'-0"

NO SCALE

8" P.C. CONCRETE PAVEMENT

6" AGGREGATE BASE COURSE

6" COMPACTED SUBGRADE (90%)

P.C. CONCRETE PAVEMENT INTERFACE DETAIL

/2

/2

PAVEMENT

8" P.C. CONCRETE

W .C D

A V

E N

P O

R T

A F

A N

C

IU

L L

O

A F

A N

C

IU

L L

O

W .C D

A V

E N

P O

R T

NOTES

MAXIMUM DRY DENSITY.

1. SEE SPECIFICATION FOR COMPACTION STANDARD; PERCENT SHOWN IS OF

6" AGGREGATE BASE COURSE

BASE COURSE

6" AGGREGATE

F -5

-0

6" SUBBASE COURSE

SUBGRADE (90%)

6" COMPACTED

TYPICAL HMA PAVEMENT SECTION W/ CURB & GUTTER

6" COMPACTED SUBGRADE (90%)

NO SCALE

6" AGGREGATE BASE COURSE

6" AGGREGATE PAVEMENT

TYPICAL AGGREGATE PAVEMENT SURFACE SECTION

4.5" HMA WEARING COURSE

4.5" HMA PAVEMENT

W -2

-R -0

1'-0" 1'-0"

6" SUBBASE COURSE

4" CONCRETE MEDIAN/CONCRETE SIDEWALK AS SHOWN

A

M M

E D

IA

N T

Y P

IC

A L

NO SCALE

TYPICAL MEDIAN SECTION

/4 /2

25.418

.4

.4

25.510

25.544

.5

.6

.4

(P O

R T C

H

IC

A G

O H

IG

H W

A Y

(P O

R T C

H

IC

A G

O H

IG

H W

A Y

.2

.4

.4

27.516

27.9

W

.9

.97

.14

(P O

R T C

H

IC

A G

O H

IG

H W

A Y

.0

A S

T R E E T

.0

KINNE BLVD

A S

T R E E T

.9

.5

A S

T R E E T

A STREET

CP

G

G

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

S A

C R

A M

E N

T O

C A

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

®of Engineers

US Army Corps

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

O M

A H

A D

IS

T R

IC

T

M

IL

IT

A R

Y O

C E

A N T

E R

M

IN

A L

C O

N C

O R

D

P N

A C

C E

S S C

O N

T R

O L P

O

IN

T

G A

T E

ADVERTISEMENT

PBX

P B

PBX

PBX

P B X

P B X

P B X

P B

X

P B X

PBX

PBX

PBX

PBX

P B

P B

PB

PBX

PBX

P B

PB

P B

P B

P B

P B

P B

P B

PB

PB

PBX

PBX

PBX

30 30

PIV

IP

IP

IP

IP

IP

IP

IP

PBX

P B

PBX

PBX

P B X

P B X

P B X

P B

X

P B X

PBX

PBX

PBX

PBX

P B

P B

PB

PBX

PBX

P B

PB

P B

P B

P B

P B

P B

P B

PB

PB

PBX

PBX

PBX

2 31

4 5 6

PIV

S

E N

U M

B E

R

F

IL

E N

A M

E

CE100

C A

C E .d g n0 /2

/2

V

E R

A L L E

R O

S

IO

N C

O N

T R

O L P

L A

N

LEGEND

SILT FENCE

EROSION CONTROL BLANKET

INLET PROTECTIONIP

SF

W .C D

A V

E N

P O

R T

A F

A N

C

IU

L L

O

A F

A N

C

IU

L L

O

W .C D

A V

E N

P O

R T

NO SCALE

KEY PLAN

N

50'025'50'

SCALE: 1" = 50'-0"

F -5

-0

W -2

-R -0

A

M G

E N

E R

A L N

O T

E /4 /2

SPEC 32 92 19 FOR ADDITIONAL DETAILS

ALL NON-PAVED AREAS DISTURBED BY CONSTRUCTION MUST BE SEEDED. SEE 1)

GENERAL NOTE:

24" RCP

INVERT = 22.569

12" RCP

INVERT = 22.581

28" RCP

INVERT = 22.740

24" RCP

INVERT = 23.439

24" RCP

INVERT = 23.487

24" RCP

INVERT = 23.869

INV= 23.884 SFT

24" RCP

INVERT = 23.884

INVERT = 24.001

12" RCP

INVERT = 24.316

INVERT = 24.715

12" RCP

INVERT = 25.350

12" RCP

INVERT = 25.530

(P O

R T C

H

IC

A G

O H

IG

H W

A Y

12" RCP

INVERT = 26.749

12" RCP

INVERT = 26.762

RANDOM PIPES

M

CP

S

A N

CP

G

SILT FENCE

EROSION CONTROL BLANKET

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

S A

C R

A M

E N

T O

C A

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

®of Engineers

US Army Corps

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

O M

A H

A D

IS

T R

IC

T

M

IL

IT

A R

Y O

C E

A N T

E R

M

IN

A L

C O

N C

O R

D

P N

A C

C E

S S C

O N

T R

O L P

O

IN

T

G A

T E

ADVERTISEMENT

-1

PBX

P B

PBX

PBX

P B X

P B X

P B X

P B

X

P B X

PBX

PBX

PBX

PBX

P B

P B

PB

PBX

PBX

P B

PB

P B

P B

P B

P B

P B

P B

PB

PB

PBX

PBX

PBX

2 31

4 5 6

PIV

S

E N

U M

B E

R

F

IL

E N

A M

E

CE101

C A

C E .d g n

NO SCALE

KEY PLAN

A R

E A

20'010'20'

SCALE: 1" = 20'-0"

/2

/2

R

O S

IO

N C

O N

T R

O L P

L A

N

W .C D

A V

E N

P O

R T

A F

A N

C

IU

L L

O

A F

A N

C

IU

L L

O

W .C D

A V

E N

P O

R T

LEGEND

SILT FENCE

EROSION CONTROL BLANKET

INLET PROTECTIONIP

SF

N

F -5

-0

W -2

-R -0

SPEC 32 92 19 FOR ADDITIONAL DETAILS

ALL NON-PAVED AREAS DISTURBED BY CONSTRUCTION MUST BE SEEDED. SEE 1)

GENERAL NOTE:

A

M G

E N

E R

A L N

O T

E /4 /2

12" RCP

INVERT = 26.762

24" RCP

INVERT = 26.991

24" RCP

INVERT = 27.31427

.4

12" RCP

INVERT = 27.536

12" RCP

INVERT = 27.580

27.9

INV= 28.408 SFT

.9

.97

M

.14

UNK SIZE

UNK SIZE

M

24" RCP

INVERT= 28.20

24" RCP

INVERT= 28.52

D

.0

A S

T R E E T

.0

A S

T R E E T

CO

CO

EROSION CONTROL BLANKET

EROSION CONTROL BLANKET

INLET PROTECTION

INLET PROTECTION

INLET PROTECTION

INLET PROTECTION

SILT FENCE

SILT FENCE

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

S A

C R

A M

E N

T O

C A

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

®of Engineers

US Army Corps

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

O M

A H

A D

IS

T R

IC

T

M

IL

IT

A R

Y O

C E

A N T

E R

M

IN

A L

C O

N C

O R

D

P N

A C

C E

S S C

O N

T R

O L P

O

IN

T

G A

T E

ADVERTISEMENT

PBX

PBX

PBX

P B X

P B X

P B X

P B X

PBX

PBX

PBX

PB

PBX

PBX

P B

PB

P B

P B

P B

P B

P B

PB

30 30

IP

IP

IP

IP

IP

PBX

P B

PBX

PBX

P B X

P B X

P B X

P B

X

P B X

PBX

PBX

PBX

PBX

P B

P B

PB

PBX

PBX

P B

PB

P B

P B

P B

P B

P B

P B

PB

PB

PBX

PBX

PBX

2 31

4 5 6

PIV

E N

A M

E

C A

C E .d g n

NO SCALE

KEY PLAN

LEGEND

EROSION CONTROL BLANKET

INLET PROTECTIONIP

SF

A R

E A

/2

/2

E R

O S

IO

N C

O N

T R

O L P

L A

N

W .C D

A V

E N

P O

R T

A F

A N

C

IU

L L

O

A F

A N

C

IU

L L

O

W .C D

A V

E N

P O

R T

A N

S I

D

F

IL

E N

U M

B E

R

CE102

N

F -5

-0

W -2

-R -0

SPEC 32 92 19 FOR ADDITIONAL DETAILS

ALL NON-PAVED AREAS DISTURBED BY CONSTRUCTION MUST BE SEEDED. SEE 1)

GENERAL NOTE:

A

M G

E N

E R

A L N

O T

E /4 /2

.9

.5

A S

T R E E T

A STREET

Finished Floor El. = 31.17

(BUILDING 262)

EROSION CONTROL BLANKET

EROSION CONTROL BLANKET

SILT FENCE

INLET PROTECTION

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

S A

C R

A M

E N

T O

C A

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

®of Engineers

US Army Corps

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

O M

A H

A D

IS

T R

IC

T

M

IL

IT

A R

Y O

C E

A N T

E R

M

IN

A L

C O

N C

O R

D

P N

A C

C E

S S C

O N

T R

O L P

O

IN

T

G A

T E

ADVERTISEMENT

P B

P B

P B

S T A

.5 6 P

T

S T A

.3

P O

E

IP

IP

PBX

P B

PBX

PBX

P B X

P B X

P B X

P B

X

P B X

PBX

PBX

PBX

PBX

P B

P B

PB

PBX

PBX

P B

PB

P B

P B

P B

P B

P B

P B

PB

PB

PBX

PBX

PBX

2 31

4 5 6

PIV

E N

A M

E

C A

C E .d g n

NO SCALE

KEY PLAN

EROSION CONTROL BLANKET

INLET PROTECTIONIP

SF

A R

E A

/2

/2

E R

O S

IO

N C

O N

T R

O L P

L A

N

W .C D

A V

E N

P O

R T

A F

A N

C

IU

L L

O

A F

A N

C

IU

L L

O

W .C D

A V

E N

P O

R T

A N

S I

D

F

IL

E N

U M

B E

R

CE103

N

F -5

-0

W -2

-R -0

SPEC 32 92 19 FOR ADDITIONAL DETAILS

ALL NON-PAVED AREAS DISTURBED BY CONSTRUCTION MUST BE SEEDED. SEE 1)

GENERAL NOTE:

A

M G

E N

E R

A L N

O T

E /4 /2

12" RCP

INVERT = 24.705

18" RCP

INVERT = 24.768

18" RCP

INVERT = 24.898

18" RCP

INVERT = 25.020

25.418

.4

.4

25.510

25.544

18" RCP

INVERT = 24.768

.5

.6

.4

(P O

R T C

H

IC

A G

O H

IG

H W

A Y

MTC 16-09

FENCE

.2

.4

27.516

M

MTC 16-08

MTC 16-05

(P O

R T C

H

IC

A G

O H

IG

H W

A Y

ON INFORMATION GATHERED ON-SITE

EXISTING WATER LINE DRAWN BASED

ON INFORMATION GATHERED ON-SITE

EXISTING WATER LINE DRAWN BASED

Finished Floor El. = 31.17

(BUILDING 262)

E

LATCH

GATE

SPUR

RAIL ROAD

3 MPH

SIGN-

"3004 VLT"

SEE IMAGE

RAMP

HANDICAP

BUILDING 600

GATE

BUILDING 601

ROADWAY

EDGE OF

CONCRETE

RAISED

12" WIDE

MOTCO SIGN

PAD

CONC.

COLUMN

CONC.

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

S A

C R

A M

E N

T O

C A

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

®of Engineers

US Army Corps

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

O M

A H

A D

IS

T R

IC

T

M

IL

IT

A R

Y O

C E

A N T

E R

M

IN

A L

C O

N C

O R

D

P N

A C

C E

S S C

O N

T R

O L P

O

IN

T

G A

T E

ADVERTISEMENT

PBX

P B

PBX

PBX

P B X

P B X

P B X

P B

X

P B X

PBX

PBX

PBX

PBX

P B

P B

PB

S T

A

.3

0 P C

S T A 1+

20.38 P

R C

S T A .7

P T

S T A .3

P C

S T A 5+

63.62

P R C

S T A

.5 6 P

T

S T A

.3

P O

E

S T A

.0

P I

S T

A

.0

9 P I

S T A .4

P I

S T

A

.3

P I

PBX

PBX

P B

PB

P B

P B

P B

P B

P B

P B

PB

PB

PBX

PBX

PBX

S T

A

.7

P I

S T

A .6

P I

S T

A -1

.8

P

O B

S T

A

.2

P T

S T

A

.6

P C

S T

A

.1

P C

S T

A .4 7 P I

S T

A -6

.9

P

C

S T

A

.0

0 P T

S T

A -0

.4

P I

S T

A

P O

B

S T A .5

P R

C

S T

A

.2

P T

-1 0 2 31

4 5 6

DIRT

SECURITY CAMERA

(BUILDING IA2)

PIV

Finished Floor El. = 30.93

E N

A M

E

C A

C E .d g n

NO SCALE

KEY PLAN

EROSION CONTROL BLANKET

INLET PROTECTIONIP

SF

LEGEND

A R

E A

/2

/2

E R

O S

IO

N C

O N

T R

O L P

L A

N

W .C D

A V

E N

P O

R T

A F

A N

C

IU

L L

O

A F

A N

C

IU

L L

O

W .C D

A V

E N

P O

R T

A N

S I

D

F

IL

E N

U M

B E

R

CE104

N

F -5

-0

W -2

-R -0

SPEC 32 92 19 FOR ADDITIONAL DETAILS

ALL NON-PAVED AREAS DISTURBED BY CONSTRUCTION MUST BE SEEDED. SEE 1)

GENERAL NOTE:

A

M G

E N

E R

A L N

O T

E /4 /2

KINNE BLVD

SILT FENCE

EROSION CONTROL BLANKET

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

S A

C R

A M

E N

T O

C A

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

®of Engineers

US Army Corps

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

O M

A H

A D

IS

T R

IC

T

M

IL

IT

A R

Y O

C E

A N T

E R

M

IN

A L

C O

N C

O R

D

P N

A C

C E

S S C

O N

T R

O L P

O

IN

T

G A

T E

ADVERTISEMENT

P B

X

PBX

PBX

PBX

PBX

PIV

PBX

P B

PBX

PBX

P B X

P B X

P B X

P B

X

P B X

PBX

PBX

PBX

PBX

P B

P B

PB

PBX

PBX

P B

PB

P B

P B

P B

P B

P B

P B

PB

PB

PBX

PBX

PBX

2 31

4 5 6

PIV

E N

A

C E .d

EROSION CONTROL BLANKET

INLET PROTECTIONIP

SF

A R

E A

/2

/2

E R

O S

IO

N C

O N

T R

O L P

L A

N

W .C D

A V

E N

P O

R T

A F

A N

C

IU

L L

O

A F

A N

C

IU

L L

O

W .C D

A V

E N

P O

R T

A N

S I

D

F

IL

E N

U M

B E

R

CE105

N

F -5

-0

W -2

-R -0

SPEC 32 92 19 FOR ADDITIONAL DETAILS

ALL NON-PAVED AREAS DISTURBED BY CONSTRUCTION MUST BE SEEDED. SEE 1)

GENERAL NOTE:

A

M G

E N

E R

A L N

O T

E /4 /2

EROSION CONTROL BLANKET

O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

C R

A M

E N

T O D

IS

T R

IC

T

J S

T R

E E

T

S A

C R

A M

E N

T O

C A

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

®of Engineers

US Army Corps

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

C

A P

IT

O L A

V E

O M

A H

A D

IS

T R

IC

T

M

IL

IT

A R

Y O

C E

A N T

E R

M

IN

A L

C O

N C

O R

D

P N

A C

C E

S S C

O N

T R

O L P

O

IN

T

G A

T E

ADVERTISEMENT

P B

PB

PBX

P B

PBX

PBX

P B X

P B X

P B X

P B

X

P B X

PBX

PBX

PBX

PBX

P B

P B

PB

PBX

PBX

P B

PB

P B

P B

P B

P B

P B

P B

PB

PB

PBX

PBX

PBX

2 31

4 5 6

PIV

E N

A M

E

C A

C E .d g n

NO SCALE

KEY PLAN

EROSION CONTROL BLANKET

INLET PROTECTIONIP

SF

N

A R

E A

/2

/2

E R

O S

IO

N C

O N

T R

O L P

L A

N

W .C D

A V

E N

P O

R T

A F

A N

C

IU

L L

O

A F

A N

C

IU

L L

O

W .C D

A V

E N

P O

R T

A N

S I

D

F

IL

E N

U M

B E

R

CE107

F -5

-0

W -2

-R -0

SPEC 32 92 19 FOR ADDITIONAL DETAILS

ALL NON-PAVED AREAS DISTURBED BY CONSTRUCTION MUST BE SEEDED. SEE 1)

GENERAL NOTE:

A

M G

E N

E R

A L N

O T

E /4 /2

T.O.B.

EL: 110'-0"

LG

M

T

LG

M

T

LG

M

T

RIDGE PLATE (PER TRUSS MFR.)

EAVE

LG

M

T

LG

M

T

LG

M

T

LG

M

T

LG

M

T

51' - 0"

LG

M

T

2'

6" 2'

6"

0"

0"

S-302GH

S-302GH

S-302GH

S-302GH

S-302GH

S-302GH

LG

M

T

LG

M

T

2' - 6" 2' - 6"

4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 3' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0"

SEE NOTE 2

CMU SHEAR WALLCMU SHEAR

WALL TO

DECK BELOW

4' - 0"

LG

M

T

B C D EA

TEMPORARY AND PERMANENT TRUSS

BRACING PROVIDED BY TRUSS MFR.

(MAX SPACING 6' O.C.) BRACING PLAN

SHALL BE SUBMITTED FOR APPROVAL

OUTLOOKERS

@ 4'-0" O.C.

MAX PER

TRUSS MFR.

DECK NOTE,

SEE S-001GH

OUTLOOKERS

@ 4'-0" O.C.

MAX PER

TRUSS MFR.

1' - 6"

SL

O

PE

/1

SL

O

PE

/1

1' - 6"

S-302GH

HSS COLUMN

W8X18 T.O.S.= 108'-0"

S-302GH

W8X18

W8X18 SEE NOTE 2

BLOCKING (TYP.

PER TRUSS MFR.)

BLOCKING (TYP.

PER TRUSS MFR.)

EAVE

EA

VE

EA

VE

BLOCKING

(TYP. PER

TRUSS MFR.)

BLOCKING

(TYP. PER

TRUSS MFR.)

S-302GH

NOTES:

1. SEE SHEET S-103VC FOR LOADING DIAGRAMS AND ADDITIONAL INFORMATION

2. OMIT BLOCKING BETWEEN TRUSSES AT LOCATIONS INDICATED TO PROVIDE

VENTILATION OF THE ATTIC SPACE.

* UNFACTORED SHEAR FORCE ACTING ON ROOF DIAPHRAGM, "E" FOR EARTH,

"W" FOR WIND

* E: 23K W: 4.7K

* E: 23K W: 19.6K

US Army Corps of Engineers ®

SHEET

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

S-102GH

R O

O F

FR

AM

IN

G

P

LA

N

M

IL

IT

AR

Y O

C

EA

N T

ER

M

IN

AL

, C O

N C

O R

D

AC

C

ES

S C

O N

TR

O

L

PO

IN

T

(G

AT

E 1)

PN

SA

C

R

AM

EN

TO

D

IS

TR

IC

T

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S O

M

AH

A D

IS

TR

IC

T

C

AP

IT

O

L

AV

E.

O

M

AH

A, N

E

C . W

AL

LI

S

C . W

AL

LI

S

W . B

O

EC

K

K.

C

H

AN

/2

2/

W

8-

-R

-0

C A4

4- D

M _S

7.

R

VT

F8

-5 0-

ADVERTISEMENT

S-

2G H

3/8" = 1'-0"S-102GH

1 ROOF FRAMING PLAN

0 2' 4' 6'

PLAN NORTH

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AM

E N D

- G

EN

ER

AL

R

EV

IS

IO

N

S

/0 4/

2 0

N

TR

O L

JO

IN

T

#5 CORNER

BAR

#5 "T"

INTERSECTION

DOWELS

NOTE 3

#5 DOWEL

U.N.O.

110' - 0"

BOND BEAM

W/ 2 #5

BARS

24"

24"

NOTE 2

C O

N

TR

O L

JO

IN

T

C O

N

TR

O L

JO

IN

T

S-303GH

TOB ELEV

110'-0"

#5 VERT BAR @ 40"

OC

46' - 0"

1'

4" 7'

4"

2'

8"

4'

0" 3'

4"

W8, SEE

S102GH

100' - 0"

TOG ELEV

12' - 0" 8' - 8" 12' - 8"

#5 VERT BAR

@ 40" O.C., U.N.O.

STEEL ROOF

S-501GH

Sim

C

O N

TR

O

L

JO

IN

T

#5 "T"

INTERSECTION

DOWELS

#5 DOWEL

U.N.O.

#5 VERT.

BAR @ 40"

O.C., U.N.O.

#5 CORNER BAR

BOND BEAM W/

2 #5 BARS

BOND BEAM W/

2 #5 BARS

24"

24"

110' - 0"

NOTE 4

C O

N

TR

O L

JO

IN

T

C O

N

TR

O L

JO

IN

T

8' - 8" 10' - 0" 14' - 8"

TOB ELEV

110'-0"

2'

1/

8" 4'

0"

3'

4" 2'

8"

W8, SEE S-102GH

100' - 0"

TOG ELEV

46' - 0"

STEEL ROOF DECK

S-501GH

Sim

US Army Corps of Engineers ®

SHEET

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

S-201GH

N O

R

TH

A N

D S

O U

TH

C

M U

W

AL

L

EL

EV

AT

IO

N

S

M

IL

IT

AR

Y O

C

EA

N T

ER

M

IN

AL

, C O

N C

O R

D

AC

C

ES

S C

O N

TR

O

L

PO

IN

T

(G

AT

E 1)

PN

SA

C

R

AM

EN

TO

D

IS

TR

IC

T

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S O

M

AH

A D

IS

TR

IC

T

C

AP

IT

O

L

AV

E.

O

M

AH

A, N

E

C . W

AL

LI

S

C . W

AL

LI

S

W . B

O

EC

K

K.

C

H

AN

/2

2/

W

8-

-R

-0

C A4

4- D

M _S

7.

R

VT

F8

-5 0-

ADVERTISEMENT

S-

1G H

3/8" = 1'-0"S-201GH

2 SOUTH ELEVATION

3/8" = 1'-0"S-201GH

1 NORTH ELEVATION

ELEV

ELEV

NOTES FOR ALL ELEVATIONS:

1. 1/4" DIA. SMOOTH TIES IN MORTAR JOINTS, SEE DETAIL 7/ S-501GH.

2. ALL CELLS GROUTED FULL IN ALL CMU WALL ELEVATIONS.

3. HORIZONTAL JOINT REINFORCEMENT PLACED AT 16" O.C., SEE DETAIL

3/S-501 GH.

FRAMING ELEVATION LEGEND

0 2' 4' 6'

0 2' 4' 6'

PLAN NORTH

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AM

E N D

- G

EN

ER

AL

R

EV

IS

IO

N

S

/0 4/

2 0

T.O.S 108'-0"

T.O.B.

110'-0"

T.O.F.

100'-0"

T.O.F.

100'-0"

T.O.F.

100'-0"

#5 VERT.

BAR @ 40"

O.C., U.N.O.

#5 DOWEL

U.N.O.

BOND BEAM

W/ 2 #5 BARS

S-301GH

S-303GH

W8, SEE

S102GH

3'

4"

#5

CORNER

24"

24"

OUTLOOKERS, SEE S102GH

BLOCKING, SEE S102GH

4'

0"

STEPPED BOND

BEAM W/ 2 #5 BARS

W/ 2'-6" LAP LENGTH

18' - 8"

#5 VERT.

BAR U.N.O.

#5 DOWEL

U.N.O.

BOND BEAM

W/ 2 #5 BARS

#5

CORNER

24"

24"

#5 VERT .

BARS @ 40"

O.C.

T.O.B.

7'

4" 1'

4"

110' - 0"

OUTLOOKERS, SEE S102GH

BLOCKING, SEE S102GH

BOND BEAM

W/ 2 #5 BARS

#5

CORNER

BAR

24"

24"

STEPPED BOND

BEAM W/ 2 #5 BARS

W/ 2'-6" LAP LENGTH

S-501GH

Sim

S-301GH

17' - 4"

110' - 0"

#5 DOWEL

BOND BEAM

W/ 2 #5 BARS

18' - 8"

INTERSECTING

8" CMU

2 #5 "T"

INTERSECTION

DOWELS

S-302GH

#5 VERT . BARS @ 40" O.C.

T.O.B.

110'-0"

S-302GH

STEPPED BOND BEAM

W/ 2 #5 BARS W/ 2'-6"

LAP LENGTH

US Army Corps of Engineers ®

SHEET

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

S-202GH

EA

ST

A N

D W

ES

T

C M

U W

AL

L

EL

EV

AT

IO

N S

M

IL

IT

AR

Y O

C

EA

N T

ER

M

IN

AL

, C O

N C

O R

D

AC

C

ES

S C

O N

TR

O

L

PO

IN

T

(G

AT

E 1)

PN

SA

C

R

AM

EN

TO

D

IS

TR

IC

T

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S O

M

AH

A D

IS

TR

IC

T

C

AP

IT

O

L

AV

E.

O

M

AH

A, N

E

C . W

AL

LI

S

C . W

AL

LI

S

W . B

O

EC

K

K.

C

H

AN

/2

2/

W

8-

-R

-0

C A4

4- D

M _S

7.

R

VT

F8

-5 0-

ADVERTISEMENT

S-

2G H

3/8" = 1'-0"S-202GH

1 WEST ELEVATION

3/8" = 1'-0"S-202GH

2 EAST ELEVATION

3/8" = 1'-0"S-202GH

3 INTERIOR ELEVATION

EL

EV1 EL

EV 2

EL

EV3

NOTES FOR ALL ELEVATION VIEWS:

1. 1/4" DIA. SMOOTH TIES IN MORTAR JOINTS, SEE DETAIL 7/ S-501GH

2. ALL CELLS GROUTED FULL IN ALL CMU WALL ELEVATIONS.

3. HORIZONTAL JOINT REINFORCEMENT PLACED AT 16" O.C., SEE DETAIL

3/S-501 GH.

FRAMING ELEVATION LEGEND

0 2' 4' 6'

0 2' 4' 6'

0 2' 4' 6'

PLAN NORTH

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AM

E N D

- G

EN

ER

AL

R

EV

IS

IO

N

S

/0 4/

2 0

T.O.B.

EL: 110'-11"

T.O.B.

EL: 110'-11"

T.

O

.B

EL

: 1

'-1

1"

T.

O

.B

EL

: 1

'-1

1"

GABLE TRUSS

TRUSS SHALL BE

PLACED DIRECTLY

ABOVE THE INTERIOR

SHEAR WALL

GABLE TRUSS

LGMT1

27' - 11"

EA

VE

1 1/2" WIDE RIB

METAL ROOF DECK

TYP. SEE SCHEDULE

ON SHT S-001VCC

TEMPORARY AND PERMANENT TRUSS

BRACING PROVIDED BY TRUSS MFR.

(MAX SPACING 6' O.C.) BRACING PLAN

SHALL BE SUBMITTED FOR APPROVAL

S-302VC

2'

6" 2'

6"

2'

6" 2'

6"

2' - 6" 2' - 6"

4'

0" 4'

9"

4'

4'

0" 4'

0"

4'

0" 4'

0"

4'

0"

S-302VC

S-302VC

4' - 0"2' - 6" 4' - 0"

COMPLETELY SHEATH

TOP CHORD OF TRUSSES

BELOW BEFORE BUILDING

ROOF FRAMING ABOVE

S-302VC

6' - 6"

S-302VC

S-302VC

S-302VC

S-302VC

S-302VC

S-302VC

S-302VC

S-302VC

TYP

LG

M

T2

LG

M

T3

SLOPE 4/12SLOPE 4/12

SL

O

PE

/1

SL

O

PE

/1

OUTLOOKERS 4'-0" O.C.

BY TRUSS MFR.

BLOCKING BY

TRUSS MFR.

R

ID

G E

PL

AT

E (P

ER

T

R U

SS

M

FR

OUTLOOKERS 4'-0" O.C.

BY TRUSS MFR.

CB

A

OUTLOOKERS

SEE OPPS. NOTES

BLOCKING BY TRUSS MFR.

G

AB

LE

T

R U

SS

NOTES:

1. SEE SHEET S-103VC FOR LOADING DIAGRAMS AND ADDITIONAL INFORMATION

2. OMIT BLOCKING BETWEEN TRUSSES AT LOCATIONS INDICATED TO PROVIDE

VENTILATION OF THE ATTIC SPACE.

* UNFACTORED SHEAR FORCE ACTING ON ROOF DIAPHRAGM, "E" FOR EARTH,

"W" FOR WIND

EA

VE

EA

VE

EAVE

EAVE

LGMT1

LGMT1

LGMT1

LGMT1

LGMT1

LGMT1

* E: 16.4K W: 12K

* E: 16.4K W: 8.9K

US Army Corps of Engineers ®

SHEET

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

S-102VC

R O

O F

FR

AM

IN

G

P

LA

N

M

IL

IT

AR

Y O

C

EA

N T

ER

M

IN

AL

, C O

N C

O R

D

AC

C

ES

S C

O N

TR

O

L

PO

IN

T

(G

AT

E 1)

PN

SA

C

R

AM

EN

TO

D

IS

TR

IC

T

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S O

M

AH

A D

IS

TR

IC

T

C

AP

IT

O

L

AV

E.

O

M

AH

A, N

E

C . W

AL

LI

S

C . W

AL

LI

S

W . B

O

EC

K

K.

C

H

AN

/2

2/

W

8-

-R

-0

C A4

4- D

M _S

7.

R

VT

F8

-5 0-

ADVERTISEMENT

S-

2V C

3/8" = 1'-0"S-102VC

1 ROOF FRAMING PLAN

0 2' 4' 6'

PLAN NORTH

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AM

E N D

- G

EN

ER

AL

R

EV

IS

IO

N

S

/0 4/

SEE PLAN, S-102VC

SE

E

PL

AN

, S -1

VC

EAVE

EAVE

EA

VE

EA

VE

R

ID

G E

VALL

EY

VALLEY

RIDGE

SEE PLAN, S-102VC

SE

E

PL

AN

, S -1

VC

EAVE

EAVE

EA

VE

EA

VE

R

ID

G E

VALL

EY

VALLEY

RIDGE

STANDING

SEAM METAL

ROOF

STANDING

SEAM METAL

ROOF

WIND UPLIFT VALUES

ZONE 1: INTERIOR

ZONE 2E: EDGE

ZONE 2R: RIDGE

NOTES:

1. WIND UPLIFT LOADS ACT PERPENDICULARLY TO AND AWAY FROM

STANDING SEAM METAL ROOF.

2. REFER TO WIND UPLIFT VALUE TABLE (THIS PAGE) FOR WIND UPIFT

VALUES, BASED ON ASCE 7-16 USING COMPONENTS AND CLADDING ANALYSIS.

3. ALL DIMENSIONS GIVEN IN PLAN ARE HORIZONTAL PROJECTIONS.

ROOF LIVE LOAD VALUES

MINIMUM ROOF LIVE LOAD: 20 PSF

(GOVERNED BY CONSTRUCTION

AND MAINTENANCE LIVE LOAD)

NOTES:

1. ALL DIMENSIONS GIVEN IN PLAN ARE HORIZONTAL

PROJECTIONS.

ZONE 2N: EDGE

ZONE 3E: CORNER

ZONE 3R: RIDGE CORNER

3' - 0"

3'

0"

OVERHANG (SOFFIT) OVERHANG (SOFFIT)SPAN

DL = 13 PSF

NOTE 1

DL = 3 PLF DL = 3 PLF, SEE NOTE 3

ZONE 2E OR 3E

ZONE 1 OR 2N

NOTE 2

3' TYP.

LL = 20 PSF

ZONE 2R OR 3R

ZONE 2E OR 3E

ZONE 1 OR 2N

ZONE 2R

OR 3R

PRESSURE ON

SOFFIT IS EQUAL

TO ADJACENT

WALL PRESSURE

OVERHANG

ROOF

PRESSURE

5 5

3'-0" TYP

3'-0" TYP

3'-0" TYP 3'-0" TYP

NOTE: ROTATED FOR CLARITY.

OPPOSITE SIDE IS SIMILAR

US Army Corps of Engineers ®

SHEET

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

S-103VC

ST

AN

D

IN

G S

EA

M

M

ET

AL

R

O O

F

LO

AD

IN

G D

IA

G

R

AM

M

IL

IT

AR

Y O

C

EA

N T

ER

M

IN

AL

, C O

N C

O R

D

AC

C

ES

S C

O N

TR

O

L

PO

IN

T

(G

AT

E 1)

PN

SA

C

R

AM

EN

TO

D

IS

TR

IC

T

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S O

M

AH

A D

IS

TR

IC

T

C

AP

IT

O

L

AV

E.

O

M

AH

A, N

E

C . W

AL

LI

S

C . W

AL

LI

S

W . B

O

EC

K

K.

C

H

AN

/2

2/

W

8-

-R

-0

C A4

4- D

M _S

7.

R

VT

F8

-5 0-

ADVERTISEMENT

S-

3V C

1/8" = 1'-0"S-103VC

1 ROOF LIVE LOADS

1/4" = 1'-0"S-103VC

PRE-ENGINEERED LIGHT GAUGE FRAMING

MEMBER LOAD DIAGRAM

NOTES:

1. SUPERIMPOSED DEAD LOAD DOES NOT INCLUDE SELF-WEIGHT OF LIGHT GAGE-FRAMING MEMBER.

2. DESIGN BOTTOM CHORD:

DL = 7 PSF

DL (SOFFIT) = 2 PSF

3. DEAD LOAD AT FASCIA INCLUDES WEIGHTS OF BENT PLATE, FASCIA BOARD, AND GUTTER.

4. IN ADDITION TO DEAD LOADS SHOWN, THE BOTTOM CHORD SHALL BE DESIGNED FOR AN ADDITIONAL SINGLE CONCENTRATED LOAD OF 0.2 K

AT EACH PANEL POINT (APPLY ONE CONCENTRATED LOAD AT A TIME).

5. IN ADDITION TO LIVE LOADS SHOWN, THE TOP CHORD SHALL BE DESIGNED FOR AN ADDITIONAL SINGLE CONCENTRATED LOAD OF 0.3 K

WHICH CAN BE LOCATED AT ANY POINT ALONG THE MEMBER.

6. IN ADDITION TO LOADS SHOWN, CONNECTION SHALL BE DESIGNED TO RESIST 1.0 K OF LIVE LOAD IN ANY HORIZONTAL DIRECTION.

7. THE LOADS SHOWN ARE FOR LIGHT GAGE FRAMING MEMBER LGMT1.

8. REQUIRED MAX LIVE LOAD DEFLECTION = L/360

REQUIRED MAX TOTAL DEFLECTION = L/240

9. THE TRUSSES MUST BE DESIGNED FOR AN ADDITIONAL 3.3K OF AXIAL LOAD DUE TO OUT OF PLANE FORCES AT THE TOP OF THE WALLS.

10. (+) VALUES REFER TO LOADS ACTING UPWARDS. (-) VALUES REFER TO LOADS ACTING DOWNWARDS.

11. FOR ADDITIONAL INFORMATION, SEE SHEET S-001VC AND SPECIFICATION SECTION 05 40 00.

WALL 5 -25.3 18.9

WALL 4 -20.5 18.9

3R -89.8 16.0

3E -78.7 16.0

2N -58.9 16.0 -54.1 16.0 -47.7 16.0 -41.3 16.0

2R -50.9 16.0 -44.5 16.0 -34.9 16.0 -28.5 16.0

2E -42.9 16.0 -42.9 16.0 -33.3 16.0 -26.9 16.0

1 -34.9 16.0 -34.9 16.0 -22.1 16.0 -16.0 16.0

< 10 20 50 > 100

ZONE

TRIBUTARY AREA SQUARE FOOTAGE (FT^2)

WIND UPLIFT VALUES (PSF)

WIND UPLIFT DIAGRAM LIVE LOAD

8'0 4' 16'

4' 8'0 2'

PLAN NORTH

ROOF SOFFIT WIND LOADS

3/16" = 1'-0"S-103VC

4 VCC WALL C&C WIND LOADS

0 4' 8' 12'

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AM

E N D

- G

EN

ER

AL

R

EV

IS

IO

N

S

/0 4/

FINISH FLOOR 600T200-43

BRIDGING

@ 48" O.C. MAX

PER MFR.

2-600S200-43

GABLE END TRUSS,

BY TRUSS MFR.

2-600S200-43

22' - 10"

@ 16" O.C.

600S200-43

100' - 0"

7/16" RATED STAGGERED

SHEATHING (OSB),

SEE NOTE 4, 5, 6

600T200-43

TBE

OUTLOOKERS, SEE S102GH

BLOCKING, SEE S102GH

110' - 11"

100' - 0"

FINISH FLOOR

600T200-43

600T200-43

2-

0S

0-

2-

0S

0-

BRIDGING

@ 48" O.C. MAX

PER MFR.

BRIDGING

@ 48" O.C. MAX

PER MFR.

600T200-4

2-

0S

0-

2-

0S

0-

3' - 0" 9' - 0" 3' - 0"

2-600S200-43 & 2-600T200-43

2-600S200-43 & 2-600T200-43

600T200-43 600T200-43

@ 16" O.C.

600S200-43

@ 16" O.C.

600S200-43

@ 16" O.C.

600S200-43

22' - 10"

3' - 11" 3' - 11"

@ 16" O.C.

600S200-43

@ 16" O.C.

600S200-43

S-303VC

7/16" RATED STAGGERED

SHEATHING (OSB),

SEE NOTE 4, 5, 6

600T200-43

2-

0S

0-

2-

0S

0-

S-302VC

GABLE END TRUSS, BY TRUSS MFR.

TBE

5'

0" 4'

0"

1'

OUTLOOKERS, SEE S102GH

BLOCKING, SEE S102GH

HOLDOWN LOCATION, SEE LIGHT

GAGE METAL FRAMING

CONNECTION SCHEDULE ON

SHEET S-001VC FOR MORE

DETAILS

110' - 11"

HOLDOWN LOCATION, SEE LIGHT

GAGE METAL FRAMING

CONNECTION SCHEDULE ON

SHEET S-001VC FOR MORE DETAILS

FINISH FLOOR

600T200-43

BRIDGING

@ 48" O.C. MAX

PER MFR.

BRIDGING

@ 48" O.C. MAX

PER MFR.

2-600S200-43

22' - 10"

2-600S200-43

600T200-43110' - 11"

TBE

7/16" RATED STAGGERED

SHEATHING (OSB),

SEE NOTE 4, 5, 6

100' - 0"

US Army Corps of Engineers ®

SHEET

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

S-201VC

N O

R

TH

A N

D S

O U

TH

F

R

AM

IN

G

EL

EV

AT

IO

N S

M

IL

IT

AR

Y O

C

EA

N T

ER

M

IN

AL

, C O

N C

O R

D

AC

C

ES

S C

O N

TR

O

L

PO

IN

T

(G

AT

E 1)

PN

SA

C

R

AM

EN

TO

D

IS

TR

IC

T

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S O

M

AH

A D

IS

TR

IC

T

C

AP

IT

O

L

AV

E.

O

M

AH

A, N

E

C . W

AL

LI

S

C . W

AL

LI

S

W . B

O

EC

K

K.

C

H

AN

/2

2/

W

8-

-R

-0

C A4

4- D

M _S

7.

R

VT

F8

-5 0-

ADVERTISEMENT

S-

1V C

3/8" = 1'-0"S-201VC

1 NORTH ELEVATION

3/8" = 1'-0"S-201VC

2 SOUTH ELEVATION

3/8" = 1'-0"S-201VC

3 INTERIOR ELEVATION

ELEV

ELEV

WALL ELEVATION NOTES:

1. WALL FRAMING DIMENSIONS ARE TO FACE OF FRAMING MEMBERS, TYPICAL.

2. OPENING WIDTH AND LOCATION DIMENSIONS ARE FOR ROUGH OPENING.

3. OVERALL WALL DIMENSIONS ARE TO OUTSIDE OF FRAMING.

4. SHEATHING SHALL BE OF 7/16" RATED STAGGERED OSB, ONE SIDE (FULL HEIGHT), ORIENTED PARALLEL TO FRAMING.

5. SHEATHING SHALL BE ATTACHED WITH EDGE FASTENERS (6" O.C., STAGGERED) AND FIELD FASTENERS (12" O.C.). BLOCKING WILL BE USED, AS REQUIRED, TO

ACHIEVE EDGE FASTENER SPACING. FASTENERS SHALL BE #8 (MINIMUM) SCREWS.

6. PLYWOOD, STRUCTURAL-USE, AND ORIENTED STRAND BOARD (OSB) PANELS SHALL ADHERE TO APA L870, APA S350, APA E445, AND APA F405 RESPECTIVELY.

FRAMING ELEVATION LEGEND

0 2' 4' 6'

0 2' 4' 6' 0 2' 4' 6'

GABLE TRUSS BY TRUSS MFR.

PLAN NORTH

ELEV

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AM

E N D

- G

EN

ER

AL

R

EV

IS

IO

N

S

/0 4/

2 0

TBE

FINISH 600T200-43 600T200-43

600T200-43

600T200-43

600T200-43

600T200-43 600T200-43

2-

0S

0-

2-

0S

0-

2-

0S

0-

2-

0S

0-

2-

0S

0-

2-

0S

0-

BRIDGING

@ 48" O.C. MAX

PER MFR.

BRIDGING

@ 48" O.C. MAX

PER MFR.

S-301VC

5' - 11" 3' - 0" 8' - 4" 3' - 4" 6' - 2" 3' - 4"

@ 16" O.C.

600S200-43

@ 16" O.C.

600S200-43

@ 16" O.C.

600S200-43

@ 16" O.C.

600S200-43

@ 16" O.C.

600S200-43

@ 16" O.C.

600S200-43

@ 16" O.C.

600S200-43

600S200-43

2-600S200-43 & 2-600T200-43

2-600S200-43 & 2-600T200-43

2-600S200-43 & 2-600T200-43

100' - 0"

600T200-43 110' - 11"

S-303VC

TYP

7/16" RATED STAGGERED

SHEATHING (OSB),

SEE NOTE 4, 5, 6

5'

0" 4'

0"

1'

7'

2"

GC SHALL ENSURE ALL

TRUSSES ARE INSTALLED

DIRECTLY ABOVE A STUD

STEEL ROOF DECK

OUTLOOKERS

S-303VC

S-303VC

HOLDOWN LOCATION, SEE LIGHT

GAGE METAL FRAMING CONNECTION

SCHEDULE ON SHEET S-001VC FOR

MORE DETAILS

33' - 6"

FINISH 600T200-43 600T200-43

600T200-43

600T200-43

2-

0S

0-

2-

0S

0-

43 BRIDGING

@ 48" O.C. MAX

PER MFR.

BRIDGING

@ 48" O.C. MAX

PER MFR.

600T200-43

2-

0S

0-

2-600S200-43 STUDS

TO ALIGN WITH

VESTIBULE WALL

2- 600S200-43

7' - 9"15' - 8"3' - 4"

100' - 0"

2-600S200-43 & 2-600T200-43

2-600S200-43 & 2-600T200-43

600T200-43

@ 16" O.C.

600S200-43

@ 16" O.C.

600S200-43

@ 16" O.C.

600S200-43

@ 16" O.C.

600S200-43

2-

0S

0-

3' - 4"

110' - 11"

@ 16" O.C.

600S200-43

3' - 5"

S-303VC

S-303VC

TYP

7/16" RATED STAGGERED

SHEATHING (OSB),

SEE NOTE 4, 5, 6

TBE

7'

2"8'

8" 2'

3"

GC SHALL ENSURE ALL

TRUSSES ARE INSTALLED

DIRECTLY ABOVE A STUD

STEEL ROOF DECK

OUTLOOKERS

HOLDOWN LOCATION, SEE LIGHT

GAGE METAL FRAMING

CONNECTION SCHEDULE ON SHEET

S-001VC FOR MORE DETAILS

US Army Corps of Engineers ®

SHEET

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

S-202VC

EA

ST

A N

D W

ES

T

FR

AM

IN

G

E

LE

VA

TI

O N

S

M

IL

IT

AR

Y O

C

EA

N T

ER

M

IN

AL

, C O

N C

O R

D

AC

C

ES

S C

O N

TR

O

L

PO

IN

T

(G

AT

E 1)

PN

SA

C

R

AM

EN

TO

D

IS

TR

IC

T

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S O

M

AH

A D

IS

TR

IC

T

C

AP

IT

O

L

AV

E.

O

M

AH

A, N

E

C . W

AL

LI

S

C . W

AL

LI

S

W . B

O

EC

K

K.

C

H

AN

/2

2/

W

8-

-R

-0

C A4

4- D

M _S

7.

R

VT

F8

-5 0-

ADVERTISEMENT

S-

2V C

3/8" = 1'-0"S-202VC

1 EAST ELEVATION

3/8" = 1'-0"S-202VC

2 WEST ELEVATION

EL

EV2

EL

EV 1

FRAMING ELEVATION LEGEND

0 2' 4' 6'

0 2' 4' 6'

WALL ELEVATION NOTES:

1. WALL FRAMING DIMENSIONS ARE TO FACE OF FRAMING MEMBERS, TYPICAL.

2. OPENING WIDTH AND LOCATION DIMENSIONS ARE FOR ROUGH OPENING.

3. OVERALL WALL DIMENSIONS ARE TO OUTSIDE OF FRAMING.

4. SHEATHING SHALL BE OF 7/16" RATED STAGGERED OSB, ONE SIDE (FULL HEIGHT), ORIENTED PARALLEL TO FRAMING.

5. SHEATHING SHALL BE ATTACHED WITH EDGE FASTENERS (6" O.C., STAGGERED) AND FIELD FASTENERS (12" O.C.). BLOCKING WILL BE USED, AS REQUIRED, TO

ACHIEVE EDGE FASTENER SPACING. FASTENERS SHALL BE #8 (MINIMUM) SCREWS.

6.PLYWOOD, STRUCTURAL-USE, AND ORIENTED STRAND BOARD (OSB) PANELS SHALL ADHERE TO APA L870, APA S350, APA E445, AND APA F405 RESPECTIVELY.

PLAN NORTH

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AM

E N D

- G

EN

ER

AL

R

EV

IS

IO

N

S

/0 4/

2 0

SITE/CIVIL
CD103DEMOLITION PLAN - AREA 103
CS103SITE PLAN - AREA 103
CS503MISC. SITE DETAILS
CS506HANDICAP RAMP DETAILS
CS508SIDEWALK JOINTS DETAIL
CG302TYPICAL ROAD SECTIONS
CP101PAVING PLAN - AREA 101
CP102PAVING PLAN - AREA 102
CP103PAVING PLAN - AREA 103
CP301TYPICAL PAVEMENT SECTIONS
CE100OVERALL EROSION CONTROL PLAN
CE101EROSION CONTROL PLAN - AREA 101
CE102EROSION CONTROL PLAN - AREA 102
CE103EROSION CONTROL PLAN - AREA 103
CE104EROSION CONTROL PLAN - AREA 104
CE105EROSION CONTROL PLAN - AREA 105
CE107EROSION CONTROL PLAN - AREA 107
GATEHOUSE
STRUCTURAL
S-102GHROOF FRAMING PLAN
S-201GHNORTH AND SOUTH CMU WALL ELEVATIONS
S-202GHEAST AND WEST CMU WALL ELEVATIONS
VISITOR CONTROL CENTER
STRUCTURAL
S-102VCROOF FRAMING PLAN
S-103VCSTANDING SEAM METAL ROOF LOADING DIAGRAM
S-201VCNORTH AND SOUTH FRAMING ELEVATIONS
S-202VCEAST AND WEST FRAMING ELEVATIONS

File details come from the government source that posted it. Updated .