Drawing_CD301_Amd_1.pdf

PDF 143 KB Posted

Attached to
FY18 West Center Pier Bollard Replacement
Solicitation number
W911XK18B0005
Issued by

About this file

Drawing CD301_Amd 1.pdf

View the file

Other files

File Type Posted
Bid_Abstract_W911XK18B0005.pdf PDF
Drawing_CU401_Amd_1.pdf PDF
W911XK18B0005-Amendment_0001.pdf PDF
Drawing_G-001_Amd_1.pdf PDF
Drawing_V-102_Amd_1.pdf PDF
Drawing_V-103_Amd_1.pdf PDF
Drawing_S-301_Amd_1.pdf PDF
Drawing_CD103_Amd_1.pdf PDF
Drawing_CD102_Amd_1.pdf PDF
Site_Visit_Sign_In_Sheet_21June2018.pdf PDF
Specification_01_99_90_Attachments.pdf PDF
Solicitation_W911XK18B0005.pdf PDF
Specifications_-_W911XK18B0005.pdf PDF
Drawings_-_W911XK18B0005.pdf PDF
Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CD301

A E

C

G -0

.d g n

GRASS

EXIST

APPROX 4"

THICKNESS

TO BE REMOVED

OVERLAY

EXIST BITUMINOUS

REMOVED

TO BE

BOLLARD

EXIST MOORING

APPROX 4"

THICKNESS

TO BE REMOVED

OVERLAY

EXIST BITUMINOUS

CAP TO REMAIN

EXIST CONC MONOLITH

TO REMAIN

EXIST TIMBER FENDER

42" W X 42" L X 51" D.

REMOVED APPROX.

FOUNDATION TO BE

EXISTING MOORING

D1 0 4' 8'2'SCALE: 1/4" = 1'

CD301

CD103

CD102

TO BE REMOVED

APPROX 1' X 1'

CONCRETE STRUT

EXIST REINFORCED

TYPICAL DEMOLITION CROSS SECTION AT BOLLARD

TO BE REMOVED

BANK TO REMAIN

EXISTING DUCT

CONTRACTOR SHALL TAKE CARE NOT TO DISTURB REMAINING DUCT BANK.2.

OTHERWISE.

ALL ITEMS MARKED FOR REMOVAL ARE TO BE DISPOSED OF UNLESS NOTED1.

D E

M O

L

IT

IO

N D

E T

A

IL

S

GENERAL NOTES

BE REMOVED

EXISTING SUBGRADE TO

U N

D E

R C

U T

DUCT BANK

DO NOT UNDERMINE EXISTING

A

BANK TO BE REMOVED

EXISTING ABANDONED DUCT

A M

E N

D M

E N

T N

O

/2

/1

A

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

S

IZ

E

S U

B M

IT

T E

D B

Y

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

SHEET ID

S

A AF

E

Y

Y

T

P S

C O

R P

S

O F

E N

G

IN

E E

R S

D E

T R

IT

D

IS

T R

IC

T

In c r e a s e

P r o f it .S u b m it

V

E C

P 'S

V a lu e

E n g in e e r in g

W

X K -X

X -X -X

X X

X

A N

S I

D

P

H

IL

L

IP

R

O

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

®of Engineers

US Army Corps

D E

T R

O

IT

D

IS

T R

IC

T

A

B

C

D

E

F

G

1 2 3 4 5 6 7 8 9 10

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E

S A

U L T S

T E

M A

R

IE

S

O O L

O C

K S

M I

C H

IP

P E

W A C

O U

N T

Y

N Z

A G

E R

M

A Y

M

IC

H

IG

A N A

V E

D E

T R

O

IT

M I

F Y W

E S

T C

E N

T E

R P

IE

R

B O

L L

A R

D R

E P

L A

C E

M E

N T

C T

R O

M M

E R

W

X K -1

-B -0

B

D A

W S

N

CERTIFIED FINAL - READY TO ADVERTISE

M

IN

A

6'-0" 1'-0"

22'-0"

2'-0"

3'-0"

2'-6" (+/-)

File details come from the government source that posted it.