Drawing_CD102_Amd_1.pdf

PDF 302 KB Posted

Attached to
FY18 West Center Pier Bollard Replacement
Solicitation number
W911XK18B0005
Issued by

About this file

Drawing CD102_Amd 1.pdf

View the file

Other files

File Type Posted
Bid_Abstract_W911XK18B0005.pdf PDF
Drawing_CU401_Amd_1.pdf PDF
W911XK18B0005-Amendment_0001.pdf PDF
Drawing_CD301_Amd_1.pdf PDF
Drawing_G-001_Amd_1.pdf PDF
Drawing_V-102_Amd_1.pdf PDF
Drawing_V-103_Amd_1.pdf PDF
Drawing_S-301_Amd_1.pdf PDF
Drawing_CD103_Amd_1.pdf PDF
Site_Visit_Sign_In_Sheet_21June2018.pdf PDF
Specification_01_99_90_Attachments.pdf PDF
Solicitation_W911XK18B0005.pdf PDF
Specifications_-_W911XK18B0005.pdf PDF
Drawings_-_W911XK18B0005.pdf PDF
Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PAVEMENT TO BE REMOVED

FY17 FY18

EXISTING CONCRETE

D1

CD301

D1

CD301

D1

CD301

D1

CD301

A

CONDUIT (TYP)

EXISTING ELECTRICAL

WEST CENTER PIER

BASE CONTRACT (FROM 1212E TO 1890E)

BASE CONTRACT (FROM 1212E TO 1890E)

EXISTING EDGE OF WALL

EXISTING CONCRETE

TO REMAIN

EXISTING CONCRETE

EXISTING JOINT

TO BE REMOVED

EXISTING CONCRETE

CD102

A E

C

G -0

.d g n

M A

T C

H L

IN

E C

D

REPAIRS REPAIRS

EXISTING ASPHALT

LEGEND

M A

T C

H L

IN

E T

H

IS

S

H E

E T

M A

T C

H L

IN

E T

H

IS

S

H E

E T

E X

IS

T

IN

G D

E M

O L

IT

IO

N P

L A

N

GENERAL NOTES

DETAIL IDENTIFIED AS D1 ON SHEET CD301 IS TYP. TO DEMOLITION PLANS.2.

OR MANHOLES.

1. CONTRACTOR SHALL TAKE CARE NOT TO DISTURB REMAINING DUCT BANK

CD301

CD301

A

A M

E N

D M

E N

T N

O

/2

/1

A

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

S

IZ

E

S U

B M

IT

T E

D B

Y

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

SHEET ID

S

A AF

E

Y

Y

T

P S

C O

R P

S

O F

E N

G

IN

E E

R S

D E

T R

IT

D

IS

T R

IC

T

In c r e a s e

P r o f it .S u b m it

V

E C

P 'S

V a lu e n g in e e r in g

W

X K -X

X -X -X

X X

X

A N

S I

D

P

H

IL

L

IP

R

O

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

®of Engineers

US Army Corps

D E

T R

O

IT

D

IS

T R

IC

T

A

B

C

D

E

F

G

1 2 3 4 5 6 7 8 9 10

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E

S A

U L T S

T E

M A

R

IE

S

O O L

O C

K S

M I

C H

IP

P E

W A C

O U

N T

Y

N Z

A G

E R

M

A Y

M

IC

H

IG

A N A

V E

D E

T R

O

IT

M I

F Y W

E S

T C

E N

T E

R P

IE

R

B O

L L

A R

D R

E P

L A

C E

M E

N T

C T

R O

M M

E R

W

X K -1

-B -0

B

D A

W S

N

CERTIFIED FINAL - READY TO ADVERTISE

1260 E

1380 E

1320 E

N

BENCHMARK COORDINATES

NAME E

BOLLARD COORDINATES

NEID

BM

1380 E

1260 E

1440 E

1500 E

1560 E

1620 E

1320 E

357.31307.6

298.31619.5

301.91559.5

1499.8 305.1

308.21439.7

1379.5 311.5

1319.6 314.7

317.61259.8

EXISTING LIGHT POLE

TOWER

EXISTING CAMERA

TO REMAIN

EXISTING DUCT BANK

TO REMAIN

EXISTING DUCT BANK

E

TO BE REMOVED (TYP)

EXISTING BOLLARD

WEST CENTER PIER

BANK TO BE REMOVED

EXISTING ABANDONED DUCT

CONDUIT (TYP)

EXISTING ELECTRICAL

EXISTING STOP SIGN

EXISTING LIGHT POLE

EXISTING EDGE OF WALL

EXISTING CONCRETE

1440 E

1500 E

1560 E

1620 E

MANHOLE

EXISTING ELECTRICAL

FLOW

SOUTH CANAL

TO BE REMOVED

EXISTING STRUTS

TO BE REMOVED (TYP)

EXISTING STRUTS

BANK TO BE REMOVED

EXISTING ABANDONED DUCT

FLOW

SOUTH CANAL

EXISTING GRASS

EXISTING GRASS

TO BE REMOVED

EXISTING ASPHALT

TO BE REMOVED

EXISTING ASPHALT

SCALE: 1"=10'E1

CD102

SCALE: 1"=10'A1

DEMOLITION SITE PLAN

DEMOLITION SITE PLAN

CD102

10' 20'0

10' 20'0

N

N

E

E

E

E

E

E

E

E

E

300 N

E

E

E

E

E

E

E

E

E

350 N

300 N

E

BM

File details come from the government source that posted it.