SEE SCHEDULE
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
W911XK-10-R-0006
The purpose of this Amendment is to:
1. Extent the proposal due date from 26 Mar 2010 02:00 PM to 2 April 2010 02:00PM.
2. UPDATE Specifications to Phase 1 section.
3. Delete Wage Determination MI 5 dated 2/12/10 and replace w ith MI 5 dated 3/12/10.
4. Allow additional time for questions regarding the subject amendment. If you have questions that have not been answ ered on previous RFIs, please submit questions by March 19, 2010 close of business, to allow for answ ers to be posted by March 26, 2010.
All other terms and conditions remain unchanged.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 47
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 12-Mar-2010
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W911XK-10-R-0006
X 9B. DATED (SEE ITEM 11)
29-Jan-2010
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
12-Mar-2010
CODE
CONTRACTING DIVISION
DETROIT DISTRICT, USAED
477 MICHIGAN AVE.
DETROIT MI 48226
W911XK 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
W911XK-10-R-0006
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION 00010 - SOLICITATION CONTRACT FORM
The required response date/time has changed from 26-Mar-2010 02:00 PM to 02-Apr-2010 02:00 PM.
The following have been added by full text:
AMENDMENT 0006
Solicitation Amendment No. 0006 For Solicitation No. W911XK-10-R-0006 FY10 VA Saginaw Upgrade Electrical Closets and Primary Distribution, Aleda E. Lutz VA Medical Center, Saginaw, Michigan
CHANGES TO THE WAGE DETERMINATIONS
1. SECTION 00800 – SPECIAL CONTRACT REQUIREMENTS:
DELETE General Decision Number: MI080005 01/01/2010 MI5
ADD: General Decision Number: MI100005 03/12/2010 MI5
See Attached
CHANGES TO THE PHASE 1 SPECIFICATIONS
2. SECTION 26 05 11 REQUIREMENTS FOR ELECTRICAL
INSTALLATIONS:
DELETE Paragraph 1.8.A
ADD Revised paragraph 1.8.A “All electrical work must comply with the requirements of 2008 NFPA 70 (NEC), 2010 NFPA 70B, 2009 NFPA 70E, OSHA Part 1910 subpart J, OSHA Part 1910 subpart S and OSHA Part 1910 subpart K in addition to other references required by contract.”
3. SECTION 26 09 13 ELECTRICAL POWER MONITORING AND CONTROL:
ADD the following as paragraph 2.2.A.5:
“5. Switchboard Low Voltage Power Metering:
a. System graphic.
b. Line to neutral voltage, A, B, C.
c. Line to line voltage, A-B, B-C, C-A.
d. Average line to line voltage.
e. Phase current, A, B, C. (main and feeders).
f. Phase kVA, A, B, C.
g. Total kVA.
h. Phase kVAr, A, B, C.
i. Total kVAr.
j. Phase kW, A, B, C.
k. Total kW.
l. Phase power factor, A, B, C.
m. Average power factor.
n. Circuit breaker open/closed (main and feeders).
o. Circuit breaker tripped (main and feeders).”
4. SECTION 26 13 01 MEDIUM VOLTAGE PAD MOUNTED SWITCHGEAR:
ADD paragraph 2.1.C:
“C. Provide each switch with a normally open auxiliary contact which closes when the switch is closed. Contact will be used for remote monitoring of switch position.”
5. SECTION 26 24 11 DISTRIBUTION SWITCHBOARDS:
ADD “65,000” in the blank space in paragraph 2.2.A.6.
DELETE paragraph 2.7.A.3
ADD revised paragraph 2.7.A.3:
“3. Control-Power Transformers: Dry type.”
DELETE paragraph 2.7.B
ADD revised paragraph 2.7.B:
“Provide Ethernet communications capability. Power Circuit Monitoring and Control System: Provide Square D Power Logic equipment to match existing. The Power Circuit Monitor shall be a multi-functional, digital, data acquisition and control device. The Power Circuit Monitor shall be metered over 50 values and extensive Min/Max data can be viewed on the LED display. Each Circuit Monitor shall offer true RMS metering and communications standard. Provide 0.2% accuracy true RMS metering and other powerful features such as automatic relay control, waveform capture, on-board event and data logging, and programmable logic for special applications like custom data logging and control function. On-board memory can be expanded to add 512 K or 1024K. Provide input/output modules, status inputs, a pulse output, relay outputs and analog inputs and outputs.
1. Power Circuit Monitor shall be
a. Certified ANSI C12.16 revenue accuracy
b. True RMS Metering through the 31st harmonic
c. High accuracy: 0.2% on current and voltage
d. Power quality readings displayed: THD and K-Factor
e. Harmonic Analysis Data through 63rd harmonic
f. Automatic Alarm/Relay control
g. On-board event and data logging
h. Waveform capture
i. UL listed, CSA Approved, CE Marketing, NOM Approved
j. MV-90 compatible
ADD paragraph 2.10.A.4:
“Provide circuit breaker trip units with RS585/Modbus communications capability.
Communications interconnection wiring between circuit breakers in the switchboard shall be factory installed.”
DELETE paragraph 2.11.B
ADD revised paragraph 2.11.B:
“Non-adjustable trip molded case circuit Breakers unless otherwise noted on the drawings as having solid state adjustable trip units. Feeder circuit breakers with adjustable trip units shall have the features noted above for main circuit breakers.
Non-adjustable trip molded case circuit breakers shall have the following features:
1. Molded case circuit breakers shall have automatic, trip free, non adjustable, inverse time, and instantaneous magnetic trips for 100 ampere frame size or less. Magnetic trip shall be adjustable from 3X to 10X for breakers with 600 ampere frame size and higher. Factory setting shall be LOW unless otherwise noted.
2. Breaker features shall be as follows:
a. A rugged, integral housing of molded insulating material.
b. Silver alloy contacts.
c. Arc quenchers and phase barriers for each pole.
d. Quick-make, quick-break, operating mechanisms.
e. A trip element for each pole, thermal magnetic type with long time delay and instantaneous characteristics, a common trip bar for all poles and a single operator.
f. Electrically and mechanically trip free.
g. An operating handle which indicates ON, TRIPPED and OFF positions.
h. Line and load connections shall be bolted.
i. Interrupting rating shall not be less than the maximum short circuit current available at the line.”
CHANGES TO THE PHASE 1 DRAWINGS
6. Sheet EP-500
DELETE Sheet EP-500 and ADD sheet EP-500R issued with this Amendment.
7. Sheet 19 EP-101 (Not Reissued)
DELETE Keynote 20
ADD revised Keynote 20:
“Emergency stop pushbutton, maintained contact, red mushroom head with three normally open and three normally closed contacts, NEMA 12 enclosure. Connect to Generator No. 1, No. 2 and No. 3 controls as indicated in the interconnection diagram on sheet 19 EP-500.”
8. Sheet 19 EP-500 (Not Reissued)
DELETE Keynote 12
ADD revised Keynote 12:
“From each Emergency Stop pushbutton, furnish and install 2 #14 conductors in ¾” conduit to each the control panel of Generator No. 1, No. 2 and No. 3. Connect to the generator controls to immediately stop the generator if the pushbutton is depressed.”
9. Sheet 21 EP-600
DELETE sheet 21EP-600 and ADD sheet 21EP-600R issued with this Amendment.
CHANGES TO THE PHASE I1 SPECIFICATIONS
10. SECTION 26 05 11 REQUIREMENTS FOR ELECTRICAL
INSTALLATIONS:
DELETE Paragraph 1.8.A
ADD Revised paragraph 1.8.A “All electrical work must comply with the requirements of 2008 NFPA 70 (NEC), 2010 NFPA 70B, 2009 NFPA 70E, OSHA Part 1910 subpart J, OSHA Part 1910 subpart S and OSHA Part 1910 subpart K in addition to other references required by contract.”
CHANGES TO THE PHASE I1 DRAWINGS
11. Sheet 01 ED-100 (Not Reissued)
DELETE Keynote 1
ADD revised Keynote 1:
“Remove existing panelboard. Reroute branch circuit conduits as required to new panelboard located within Switchgear Room 12B – see Sheet 01 EP-100. Patch resulting opening in wall and paint wall to match adjacent surfaces. New painted area shall extend to corners and from floor to ceiling.”
DELETE Keynote 2
ADD revised Keynote 2:
panelboard located within ECBB – see Sheet 01 EP-100. Patch resulting opening in wall and paint wall to match adjacent surfaces.”
DELETE Keynote 3
ADD revised Keynote 3:
panelboard located within ECBC – see Sheet 01 EP-100. Patch resulting opening in wall and paint wall to match adjacent surfaces. New painted area shall extend to room corners and from floor to ceiling.”
DELETE Keynote 4
ADD revised Keynote 4:
“Remove existing panelboard. Patch resulting opening in wall and paint wall to match adjacent surfaces. New painted area shall extend to the corners on each side of the panelboard and from floor to ceiling. Refeed existing Rm 140 circuits 1, 3, 11 & 13 from new panelboard 1D1 in EC1D – See sheet 01 EP-110. Refeed existing Rm 18 & 19 circuits 2, 4, 6 & 9 from new panelboard BD in ECBC – see sheet 01 EP-100.”
REVISE the Room 18 panelboard designation from BC4 to BD4.
12. Sheet 01 ED-110
DELETE sheet 01ED-110 and ADD sheet 01ED-110R issued with this Amendment.
13. Sheet 01 ED-120 (Not Reissued)
“Remove existing panelboard. Refeed existing second floor branch circuits from new panelboard located within EC2B – see Sheet 01 EP-120. Refeed existing circuits on other floors from new panelboards located in the B wing electrical closets on that floor. Patch resulting openings in wall and paint wall to match adjacent surfaces. New painted area shall extend to the edge of the door frames on either side of the panelboard and from floor to ceiling.”
panelboard located within EC2D – see Sheet 01 EP-120. Patch resulting opening in wall and paint wall to match adjacent surfaces. New painted area shall extend to the room corners on either side of the panelboard and from floor to ceiling.”
ADD panelboard R located on the east side of the corridor, outside of Cat Scan Room
272. ADD a Keynote 4 symbol adjacent to panelboard R.
ADD Keynote 4:
panelboard located within EC2B. Patch resulting opening in wall and paint wall to match adjacent surfaces. New painted area shall extend to the edge of the room 271 and 272 door frames, floor to ceiling.”
14. Sheet 01 ED-130 (Not Reissued) panelboard located within EC3B – see Sheet 01 EP-130. Patch resulting opening in wall and paint wall to match adjacent surfaces. New painted area shall extend to the edge of the nearest door frame or corner on either side of the panelboard and from floor to ceiling.”
15. Sheet 01 ED-140 (Not Reissued) panelboard located within EC4B – see Sheet 01 EP-140. Patch resulting opening in wall and paint wall to match adjacent surfaces. New painted area shall extend to the edge of the nearest door frame or corner on either side of the panelboard and from floor to ceiling.”
16. Sheet 01 ED-201 (Not Reissued) panelboard located within Switchgear Room 12B – see Sheet 01 EP-100. Patch resulting opening in wall and paint wall to match adjacent surfaces.”
17. Sheet 01 ED-261
DELETE sheet 01ED-261 and ADD sheet 01ED-261R issued with this Amendment.
18. Sheet 01 ED-401 (Not Reissued)
DISCONNECT AND REMOVE the existing oxygen system transformers located in ECBB on the wall directly above LSBB. Disconnect and remove associated conductors and conduit.
DELETE Keynote 8
ADD revised Keynote 8:
“Disconnect and remove existing timers and lighting contactor. Retain lighting contractor for reinstallation at new location – see sheet 01EP-401. Protect existing timer branch circuits for extension to new timer location at EC1B – see sheet 01EP- 411R.
19. Sheet 01 ED-601
DELETE sheet 01ED-601 and ADD sheet 01ED-601R issued with this Amendment.
20. Sheet 01 ED-603
DELETE sheet 01ED-603 and ADD sheet 01ED-603R issued with this Amendment.
21. Sheet 01 ED-604
DELETE sheet 01ED-604 and ADD sheet 01ED-604R issued with this Amendment.
22. Sheet 01 ED-610
DELETE sheet 01ED-610 and ADD sheet 01ED-610R issued with this Amendment.
23. Sheet 01 ED-612
DELETE sheet 01ED-612 and ADD sheet 01ED-612R issued with this Amendment.
24. Sheet 01 ED-617
DELETE sheet 01ED-617 and ADD sheet 01ED-617R issued with this Amendment.
25. Sheet 01 EP-001 (Not Reissued)
ADD the following as Project Note 15:
“15. All multiwire branch circuits shall comply with Article 210.4(B) of the 2008 NEC which states: Each multiwire branch circuit shall be provided with a means that will simultaneously disconnect all ungrounded conductors at the point where the branch circuit originates. At each new panelboard, for multiwire branch circuits, rearrange the circuit numbers as required and provide either a two or three pole circuit breaker or circuit breaker handle tie to comply with this NEC requirement.”
26. Sheet 01 EP-100
DELETE sheet 01EP-100 and ADD sheet 01EP-100R issued with this Amendment.
27. Sheet 01 EP-110
DELETE sheet 01EP-110 and ADD sheet 01EP-110R issued with this Amendment.
28. Sheet 01 EP-120 (Not Reissued)
“Location of existing panelboard removed as part of this project. Reroute branch circuit conduits as required from this location to the new panelboard location. See sheet 01 ED-120. Furnish and install new branch circuit conductors from new panelboard to first device or junction box in the existing branch circuit and splice to existing branch circuit conductors at that point.”
DELETE the letters “JB” shown next to the Keynote 1 symbol in the floor plan. The existing panelboard enclosures shall be completely removed and shall not be used as junction boxes.
29. Sheet 01 EP-130 (Not Reissued) circuit conduits as required from this location to the new panelboard location. See sheet 01 ED-130. Furnish and install new branch circuit conductors from new panelboard to first device or junction box in the existing branch circuit and splice to existing branch circuit conductors at that point.”
DELETE the letters “JB” shown next to the Keynote 1 symbol in the floor plan. The existing panelboard enclosures shall be completely removed and shall not be used as
DELETE the first paragraph under the heading Receptacle Testing
ADD the following as the first paragraph under the heading Receptacle Testing to read (The second paragraph shall remain unaltered):
“As part of this project, the contractor shall test all existing 120V receptacles installed on the Third Floor within Building 1. Testing shall be performed using a National Safety Technologies Model R6500 Electrical Receptacle Analyzer.
(Sarah Braceland, National Safety Technologies, Station Square Two, STE 107, Paoli, PA 19301-1320. Phone 717-419-0961. Email sbraceland@nst-usa.com) The Analyzer shall be purchased by the contractor and turned over to the Owner along with test records after testing is complete. Any receptacles which the Analyzer indicates as Bad shall be replaced.”
30. Sheet 01 EP-140 (Not Reissued) circuit conduits as required from this location to the new panelboard location. See sheet 01 ED-140. Furnish and install new branch circuit conductors from new panelboard to first device or junction box in the existing branch circuit and splice to existing branch circuit conductors at that point.”
DELETE the letters “JB” shown next to the Keynote 1 symbol in the floor plan. The existing panelboard enclosures shall be completely removed and shall not be used as
31. Sheet 01 EP-150 (Not Reissued)
“Approximate location of ceiling penetration by conduit from penthouse above. Field verify exact routing above layin ceiling. Furnish and install new conductors in existing conduit to feed new panelboard 5AAC in EC5A. See sheets 01 ED-603 and
01 EP-603.”
DELETE Keynote 3
ADD revised Keynote 3:
“Approximate location of ceiling penetration by conduits from penthouse above.
Field verify exact routing above layin ceiling. Furnish and install new conduit and conductors to feed new panelboard 5CAC in EC5C. Furnish and install new conductors in existing conduit to feed panelboard 4CAC in EC4C on floor below. See sheets 01 ED-603 and 01 EP-601.”
DELETE Keynote 4
ADD revised Keynote 4:
“Feeder conduit to panelboard 4CAC located in fourth floor electrical closet EC4C.
Field verify exact routing of feeder conduit. Furnish and install new conductors in existing conduit to feed new panelboard. See sheets 01 ED-603 and 01 EP-603.”
DELETE Keynote 5.
32. Sheet 01 EP-201
DELETE sheet 01EP-201 and ADD sheet 01EP-201R issued with this Amendment.
33. Sheet 01 EP-261
DELETE sheet 01EP-261 and ADD sheet 01EP-261R issued with this Amendment.
34. Sheet 01 EP-401
DELETE sheet 01EP-401 and ADD sheet 01EP-401R issued with this Amendment.
35. Sheet 01 EP-411
DELETE sheet 01EP-411 and ADD sheet 01EP-411R issued with this Amendment.
36. Sheet 01 EP-412
DELETE sheet 01EP-412 and ADD sheet 01EP-412R issued with this Amendment.
37. Sheet 01 EP-421
DELETE sheet 01EP-421 and ADD sheet 01EP-421R issued with this Amendment.
38. Sheet 01 EP-431 (Not Reissued)
In EC3B elevation 8, REVISE the designation of panelboard CPB3 to LSIG-3B.
39. Sheet 01 EP-441 (Not Reissued)
In EC4B elevation 8, REVISE the designation of panelboard CP4B to LSIG-4B.
40. Sheet 01 EP-451 (Not Reissued)
In EC5B elevation 8, REVISE the designation of panelboard CP5B to LSIG-5B.
41. Sheet 01 EP-501
DELETE sheet 01E--501 and ADD sheet 01EP-501R issued with this Amendment.
42. Sheet 01 EP-601
DELETE sheet 01EP-601 and ADD sheet 01EP-601R issued with this Amendment.
43. Sheet 01 EP-603
DELETE sheet 01EP-603 and ADD sheet 01EP-603R issued with this Amendment.
44. Sheet 01 EP-604
DELETE sheet 01EP-604 and ADD sheet 01EP-604R issued with this Amendment.
45. Sheet 01 EP-605
DELETE sheet 01EP-605 and ADD sheet 01EP-605R issued with this Amendment.
46. Sheet 01 EP-606
DELETE sheet 01EP-606 and ADD sheet 01EP-606R issued with this Amendment.
47. Sheet 01 EP-607
DELETE sheet 01EP-607 and ADD sheet 01EP-607R issued with this Amendment.
48. Sheet 01 EP-610
DELETE sheet 01EP-610 and ADD sheet 01EP-610R issued with this Amendment.
49. Sheet 01 EP-611
DELETE sheet 01EP-611 and ADD sheet 01EP-611R issued with this Amendment.
50. Sheet 01 EP-612
DELETE sheet 01EP-612 and ADD sheet 01EP-612R issued with this Amendment.
51. Sheet 01 EP-613 (Not Reissued)
At circuits 38 & 40 in panelboard 1A, ADD Room 117 Vending as the circuit description. Provide new branch circuit conduit and conductors to these existing Room 117 outlets from 1A. See sheet 01ED-612R.
In the panelboard 1B schedule, ADD the following description at circuits 48, 50, 52 & 54: “Recep – Front Entrance – Timer.”
52. Sheet 01 EP-615 (Not Reissued)
In the 2B schedule, add the designation Power Monitoring Gateway to circuit 64 and label all the other unlabeled circuit breaker as Spare.
53. Sheet 01 EP-616
DELETE the X-Ray Processor (Rm 271) from LS3B circuit #19 and connect this load to new panelboard E2B. Furnish and install new conductors from EC2B to the first junction box in this circuit.
54. Sheet 01 EP-617
DELETE sheet 01EP-617 and ADD sheet 01EP-617R issued with this Amendment.
55. Sheet 01 EP-623
DELETE sheet 01EP-623 and ADD sheet 01EP-623R issued with this Amendment.
END OF AMENDMENT
SECTION 00800 - SPECIAL CONTRACT REQUIREMENTS
The following have been added by full text:
WAGE DET MI 5 DATED 3/12/2010
General Decision Number: MI100005 03/12/2010 MI5
Superseded General Decision Number: MI20080005
State: Michigan
Construction Types: Building and Heavy
Counties: Bay, Genesee, Lapeer, Saginaw, St Clair and Tuscola Counties in Michigan.
BUILDING CONSTRUCTION PROJECTS (does not include residential construction consisting of single family homes and apartments up to and including 4 stories); HEAVY CONSTRUCTION PROJECTS
(does not include airport or bridge construction projects, or sewer or water line work if it is incidental to a highway construction project)
Modification Number Publication Date 0 03/12/2010
ASBE0025-002 06/01/2009
ST. CLAIR COUNTY:
Rates Fringes
ASBESTOS WORKER/INSULATOR
Includes the application of all insulating materials, protective coverings, coatings, and finishings to all types of mechanical systems..........$ 30.77 22.28
FOOTNOTE: Work requiring a spray coating in the application:
Five percent (5%) per hour additional.
ASBE0047-010 07/01/2009
Rates Fringes
ASBESTOS WORKER/INSULATOR
Includes the application of all insulating materials, protective coverings, coatings and finishings to all types of mechanical systems..........$ 28.42 15.41
BOIL0169-004 07/01/2008
Rates Fringes
BOILERMAKER......................$ 31.953 20.869
* BRMI0001-005 09/01/2009
ST. CLAIR COUNTY
Rates Fringes
CEMENT MASON.....................$ 28.77 13.43
BRMI0007-001 08/01/2008
BAY, SAGINAW AND TUSCOLA COUNTIES:
Rates Fringes
Marble, terrazzo and tile finisher.........................$ 16.72 6.93 Marble, terrazzo and tile setter...........................$ 21.94 9.75
* BRMI0009-012 10/01/2009
Rates Fringes
Bricklayer, Caulker, Cleaner, Pointer..........................$ 26.86 14.68
CEMENT MASON/CONCRETE FINISHER...$ 24.12 11.20
FINISHER.........................$ 18.18 10.24
PLASTERER........................$ 24.98 11.34
Tile, Marble & Terrazzo Worker...$ 21.53 12.26
FOOTNOTE:
Paid Holiday: Fourth of July, if the worker was employed by the contractor in any period of seven working days before said holiday within the current calendar year.
* BRMI0009-014 10/01/2009
LAPEER COUNTY:
Rates Fringes
Bricklayer, Caulker, Cleaner, Pointer & Stonemason.............$ 28.53 14.90 Cement Mason and plasterer.......$ 26.05 12.88
FINISHER.........................$ 22.45 10.52
Tile, Marble & Terrazzo Worker...$ 26.65 12.49
FOOTNOTE:
Paid Holiday: Fourth of July, if the worker was employed by the contractor in any period of seven working days before said holiday within the current calendar year.
* BRMI0010-002 06/01/2008
ST. CLAIR COUNTY:
Rates Fringes
BRICKLAYER
Bricklayer.................$ 34.05 15.33 Plasterer..................$ 30.14 13.30
FOOTNOTES:
Paid Holiday: Fourth of July, if the worker was employed by the contractor in any period of seven working days before said holiday within the current calendar year.
BRMI0010-004 08/01/2008
BAY, SAGINAW AND TUSCOLA COUNTIES:
Rates Fringes
BRICKLAYER.......................$ 25.56 12.97
CEMENT MASON/CONCRETE FINISHER...$ 23.83 11.94
FINISHER.........................$ 16.72 6.93
PLASTERER........................$ 24.76 13.02
Tile, Marble & Terrazzo Worker...$ 21.94 9.75
FOOTNOTE:
Paid Holiday: Fourth of July, if the worker is employed by the contractor in any period of seven working days before said holiday within the current calendar year.
BRMI0032-002 06/01/2009
ST. CLAIR COUNTY:
Rates Fringes
MARBLE FINISHER..................$ 24.86 16.51
MARBLE MASON.....................$ 31.34 16.51
TERRAZZO FINISHER................$ 25.33 16.51
TERRAZZO WORKER/SETTER...........$ 30.80 16.51
TILE FINISHER....................$ 24.88 16.51
TILE SETTER......................$ 30.75 16.51
FOOTNOTES: Work on scaffolding over 15 ft.: $1.25 per hour additional.Swing stage work: $1.50 per hour additional.
Terrazzo grinding: $0.50 per hour above the terrazzo finisher rate. Terrazzo work grinding vertical work and stairs: $1.50 per hour above the terrazzo finisher rate.
CARP0687-002 06/01/2007
ST. CLAIR COUNTY:
Rates Fringes
CARPENTER (Drywall Hanger).......$ 26.88 15.27 Diver............................$ 33.19 17.95 Pile Driver......................$ 26.597 25.08%+8.916
FOOTNOTES:
Piledrivers: Loftsperson or sticker:$0.55 per hour additional. Loftsperson or sticker on heights over 150 feet: $0.80 per hour additional. Welder: $0.55 per hour additional.
CARP0706-001 06/01/2008
CARPENTER
(Including drywall hangers).$ 25.64 12.87
CARP0706-002 06/01/2008
BAY, SAGINAW AND TUSCOLA COUNTIES:
Rates Fringes
CARPENTER
(Including drywall hangers).$ 25.08 12.83
CARP1045-002 06/01/2008
ST. CLAIR COUNTY:
Rates Fringes
LATHER...........................$ 23.69 13.52
* CARP1045-006 06/01/2008
GENESEE AND ST. CLAIR COUNTIES:
Rates Fringes
FLOOR LAYER: Carpet (Soft) Floor............................$ 29.10 14.117
CARP1045-017 07/17/2008
BAY, SAGINAW AND TUSCOLA COUNTIES:
Rates Fringes
LATHER...........................$ 24.29 13.66
CARP1045-018 07/17/2008
GENESEE AND LAPEER COUNTIES:
Rates Fringes
LATHER...........................$ 24.85 13.70
* ELEC0017-002 06/02/2009
LAPEER, ST. CLAIR AND TUSCOLA COUNTIES:
Rates Fringes
Line Construction Cable splicer; Line technician when helio-arc welding.....................$ 37.47 15.01 Combination driver/groundman............$ 26.05 11.90 Combination equipment operator and groundman......$ 27.61 12.32 Groundman...................$ 23.99 11.34 Lineman.....................$ 37.47 15.01
ELEC0058-001 03/01/2006
ST. CLAIR COUNTY:
Rates Fringes
ELECTRICIAN
Work on sound and communications/limited-energy systems (including inter-communication public address, paging, music, security systems, nurse call systems, telecommunications (voice and data), fiber optic cabling systems, sound systems, broadband systems, computer network systems, CCTV systems, fire detection/signaling systems, and temperature control systems)............$ 27.83 3%+6.25 All other work..............$ 33.00 3%+14.16
* ELEC0557-001 06/01/2009
SAGINAW COUNTY; TUSCOLA COUNTY (Townships of Almer, Arbela, Columbia, Dayton, Denmark, Elkland, Ellington, Elmwood, Fairgrove, Fremont, Gilford, Indianfields, Juniata, Kingston, Koylon, Novesta, Tuscola, Vassar, Watertown and Wells):
ELECTRICIAN......................$ 31.13 15.52
FOOTNOTE: High work: Electrical work thirty-five feet (35') (to the work) above the ground or permanent floor, where a hazard exists:15% per hour additional.
ELEC0692-002 06/01/2009
BAY COUNTY AND TUSCOLA COUNTY (Townships of Akron and Wisner):
ELECTRICIAN......................$ 29.46 7.20+26.33%
* ELEC0876-002 06/01/2009
BAY, GENESEE AND SAGINAW COUNTIES:
Rates Fringes
LINE CONSTRUCTION
Cable Splicer...............$ 34.87 13.38 Light Equipment Operator/Groundman/Truck Driver/Groundman (winch, A-frame, diggers when used for distribution line truck and used for distribution work.
Distribution truck driver, 5th wheel type trucks, bucket trucks, ladder trucks and all live boom trucks, all equipment 85 hp or under)................$ 22.06 10.21 Lineman/Line Technician.....$ 33.49 13.03 Operator/Groundman (digger, tractor and setting rig with tracks or rough terrain vehicle, large bombardier, backhoe over 85 hp, hydraulic crane 10 ton or over).......$ 25.18 10.99 Truck Driver/Groundman (trucks with winch or boom or dump, other than distribution work)..........$ 21.00 9.95
FOOTNOTE: Operators of 5/8 yd. rated capacity backhoe or over, and operators of 25 ton, rated capacity, crane or over, and operators of heavy duty tension or pulling machinery on 345 KV and above, shall receive the line technician rate of pay.
ELEC0948-001 06/04/2007
GENESEE AND LAPEER COUNTIES; TUSCOLA COUNTY (Township of Millington):
ELECTRICIAN......................$ 34.89 6.60+22%
Sound & Communication Technician.......................$ 22.10 6.60+15.5%
FOOTNOTES: Work on towers or stacks: double the straight time rate of pay. Work in other hazardous locations located 40 or more feet from the floor or ground to the work: 10% per hour additional. Work under compressed air in tunnels or shafts below the ground level: 15% per hour additional.
Work in an area where injurious gases or fumes are present and when instructed to wear gas masks: 15% per hour additional while working in that area and being required to wear gas masks.
ELEV0036-002 01/01/2010
ST. CLAIR COUNTY:
Rates Fringes
ELEVATOR MECHANIC................$ 42.45 20.035
FOOTNOTE: Vacation Pay: 8% with 5 or more years of service, 6% for 6 months to 5 years service. Paid Holidays: New Years Day, Memorial Day, Independence Day, Labor Day, Veterans Day, Thanksgiving Day and Friday after, and Christmas Day.
ELEV0085-002 01/01/2010
BAY, GENESEE, LAPEER, SAGINAW, AND TUSCOLA COUNTIES:
Rates Fringes
ELEVATOR MECHANIC................$ 42.73 20.035
FOOTNOTE: Vacation Pay: 8% with 5 or more years of service, 6% for 6 months to 5 years service. Paid Holidays: New Years Day, Memorial Day, Independence Day, Labor Day, Veterans Day, Thanksgiving Day and Friday after, and Christmas Day.
* ENGI0324-008 10/01/2009
ALCONA, ALGER, ALLEGAN, ALPENA, ANTRIM, ARENAC, BARAGA, BARRY,
BAY, BENZIE, BERRIEN, BRANCH, CALHOUN, CASS, CHARLEVOIX,
CHEBOYGAN, CHIPPEWA, CLARE, CLINTON, CRAWFORD, DELTA,
DICKINSON, EATON, EMMET, GENESEE, GLADWIN, GOGEBIC, GRAND
TRAVERSE, GRATIOT, HILLSDALE, HOUGHTON, HURON, INGHAM, IONIA,
IOSCO, IRON, ISABELLA, JACKSON, KALAMAZOO, KALKASKA, KENT,
KEWEENAW, LAKE, LAPEER, LEELANAU, LENAWEE, LIVINGSTON, LUCE,
MACKINAC, MACOMB, MANISTEE, MARQUETTE, MASON, MECOSTA,
MENOMINEE, MIDLAND, MISSAUKEE, MONTCALM, MONTMORENCY, MONROE,
MUSKEGON, NEWAYGO, OAKLAND, OCEANA, OGEMAW, ONTONAGON, OSCEOLA,
OSCODA, OTSEGO, OTTAWA, PRESQUE ISLE, ROSCOMMON, SAGINAW, ST.
CLARE, ST. JOSEPH, SANILAC, SCHOOLCRAFT, SHIAWASSEE, TUSCOLA,
VAN BUREN, WASHTENAW, WAYNE AND WEXFORD COUNTIES
OPERATOR: Power Equipment
(Undefined) (Sewer Relining)
GROUP 1.....................$ 28.65 11.64
GROUP 2.....................$ 27.12 11.64
SEWER RELINING CLASSIFICATIONS
GROUP 1: Operation of audio-visual closed circuit TV system, including remote in-ground cutter and other equipment used in connection with the CCTV system
GROUP 2: Operation of hot water heaters and circulation systems, water jetters and vacuum and mechanical debris removal systems
* ENGI0324-010 09/01/2009
ST. CLAIR COUNTY:
Rates Fringes
OPERATOR: Power Equipment (Undefined)
GROUP 1....................$ 37.99 17.80
GROUP 2....................$ 36.49 17.80
GROUP 3....................$ 34.99 17.80
GROUP 4....................$ 34.69 17.80
GROUP 5....................$ 33.87 17.80
GROUP 6....................$ 33.01 17.80
GROUP 7....................$ 32.04 17.80
GROUP 8....................$ 30.33 17.80
GROUP 9....................$ 23.02 17.80
GROUP 10....................$ 21.99 17.80
FOOTNOTES: Tower cranes: to be paid the crane operator rate determined by the combined length of the mast and the boom.
If the worker must climb 50 ft. or more to the work station, $.25 per hour additional. Derrick and cranes where the operator must climb 50 ft. or more to the work station, $.25 per hour additional to the applicable crane operator rate.
POWER EQUIPMENT OPERATOR CLASSIFICATIONS
GROUP 1: Crane with boom & jib or leads 400' or longer
GROUP 2: Crane with boom & jib or leads 300' or longer
GROUP 3: Crane with boom & jib or leads 220' or longer
GROUP 4: Crane with boom & jib or leads 140' or longer
GROUP 5: Crane with boom & jib or leads 120' or longer
GROUP 6: Regular crane operator, job mechanic, and concrete pump with boom operator
GROUP 7: Regular engineer, Hydro-Excavator, Remote Controlled Concrete Breaker
GROUP 8: Engineer when operating forklift, lull, extend-a-boom forklift
GROUP 9: Engineer when operating compressor or welding machine
GROUP 10: Fire tender or oiler
* ENGI0324-011 06/01/2009
Rates Fringes
OPERATOR: Power Equipment (Undefined) (Steel Erection)
GROUP 1....................$ 42.47 18.35
GROUP 2....................$ 43.47 18.35
GROUP 3....................$ 40.97 18.35
GROUP 4....................$ 41.97 18.35
GROUP 5....................$ 39.47 18.35
GROUP 6....................$ 40.47 18.35
GROUP 7....................$ 39.20 18.35
GROUP 8....................$ 40.20 18.35
GROUP 9....................$ 38.75 18.35
GROUP 10....................$ 39.75 18.35
GROUP 11....................$ 38.02 18.35
GROUP 12....................$ 39.02 18.35
GROUP 13....................$ 37.66 18.35
GROUP 14....................$ 38.66 18.35
GROUP 15....................$ 37.02 18.35
GROUP 16....................$ 30.21 18.35
GROUP 17....................$ 28.80 18.35
GROUP 18....................$ 35.57 18.35
FOOTNOTE:
Paid Holidays: New Year's Day, Memorial Day, Fourth of July, Labor Day, Thanksgiving Day and Christmas Day.
POWER EQUIPMENT OPERATOR CLASSIFICATIONS
GROUP 1: Engineer when operating combination of boom and jib 400' or longer
GROUP 2: Engineer when operating combination of boom and jib 400' or longer on a crane that requires an oiler
GROUP 3: Engineer when operating combination of boom and jib 300' or longer
GROUP 4: Engineer when operating combination of boom and jib 300' or longer on a crane that requires an oiler
GROUP 5: Engineer when operating combination of boom and jib
220' or longer
GROUP 6: Engineer when operating combination of boom and jib 220' or longer on a crane that requires an oiler
GROUP 7: Engineer when operating combination of boom and jib 140' or longer
GROUP 8: Engineer when operating combination of boom and jib 140' or longer on a crane that requires an oiler
GROUP 9: Tower crane and derrick operator (where operator's work station is 50 ft. or more above first sub-level)
GROUP 10: Tower crane and derrick operator (where operator's work station is 50 ft. or more above first sub-level) on a crane that requires an oiler
GROUP 11: Engineer when operating combination of boom and jib 120' or longer
GROUP 12: Engineer when operating combination of boom and jib 120' or longer on a crane that requires an oiler
GROUP 13: Crane operator; job mechanic; 3 drum hoist and excavator
GROUP 14: Crane operator on a crane that requires an oiler
GROUP 15: Hoisting operator; 2 drum hoist and rubber tire backhoe
GROUP 16: Compressor or welder operator
GROUP 17: Oiler
GROUP 18: Forklift and 1 drum hoist
* ENGI0324-013 09/01/2009
AREA 1: Genesee, Lapeer and St. Clair AREA 2: Bay, Midland, Saginaw, Huron and Sasnilac
(Undefined) (Undergound construction- includes sewer)
AREA 1:
GROUP 1....................$ 29.28 17.85
GROUP 2....................$ 24.55 17.85
GROUP 3....................$ 23.82 17.85
GROUP 4....................$ 23.25 17.85
(Undefined) (Underground construction- includes sewer)
AREA 2:
GROUP 1....................$ 27.57 17.85
GROUP 2....................$ 22.68 17.85
GROUP 3....................$ 22.18 17.85
GROUP 4....................$ 21.90 17.85
POWER EQUIPMENT OPERATOR CLASSIFICATIONS
GROUP 1: Backfiller tamper; Backhoe; Batch plant operator (concrete); Clamshell; Concrete paver (2 drums or larger);
Conveyor loader (Euclid type); Crane (crawler, truck type or pile driving); Dozer; Dragline; Elevating grader;
Endloader; Gradall (and similar type machine); Grader;
Mechanic; Power shovel; Roller (asphalt); Scraper (self-propelled or tractor drawn); Side boom tractor (type D-4 or equivalent and larger); Slip form paver; Slope paver; Trencher (over 8 ft. digging capacity); Well drilling rig; Concrete pump with boom operator; Hydro Excavator
GROUP 2: Boom truck (power swing type boom); Crusher; Hoist;
Pump (1 or more-6-in. discharge or larger-gas or diesel-powered or powered by generator of 300 amperes or more-inclusive of generator); Side boom tractor (smaller than type D-4 or equivalent); Tractor (pneu-tired, other than backhoe or front end loader); Trencher (8-ft. digging capacity and smaller) ; Vac Truck
GROUP 3: Air compressors (600 cfm or larger); Air compressors (2 or more-less than 600 cfm); Boom truck (non-swinging, non-powered type boom); Concrete breaker (self-propelled or truck mounted - includes compressor); Concrete paver (1 drum-l/2 yd. or larger); Elevator (other than passenger);
Maintenance person; Pump (2 or more-4-in. up to 6-in.
discharge-gas or diesel powered-excluding submersible pumps); Pumpcrete machine (and similar equipment); Wagon drill (multiple); Welding machine or generator (2 or more-300 amp. or larger-gas or diesel powered)
GROUP 4: Boiler; Concrete saw (40 hp or over); Curing machine (self-propelled); Farm tractor (with attachment); Finishing machine (concrete); Fire person; Hydraulic pipe pushing machine; Mulching equipment; Oiler; Pumps (2 or more up to 4-in. discharge, if used 3 hours or more a day, gas or diesel powered-excluding submersible pumps); Roller (other than asphalt); Stump remover; Trencher (service); Vibrating compaction equipment, self-propelled (6 ft. wide or over);
End dump operator; Sweeper (Wayne type and similar equipment); Water Wagon, Extend-a-boom Forklift
* ENGI0324-014 05/01/2009
BAY, GENESEE, LAPEER, SAGINAW AND TUSCOLA COUNTIES:
(Undefined)
GROUP 1.....................$ 28.39 17.80
GROUP 2.....................$ 28.14 17.80
GROUP 3.....................$ 27.04 17.80
GROUP 4.....................$ 22.24 17.80
GROUP 5.....................$ 21.64 17.80
GROUP 6.....................$ 19.19 17.80
GROUP 7.....................$ 17.49 17.80
FOOTNOTES:
Certified Crane Operator Premiums:
a) Swing Boom Truck Operator over 12 tons-$.50 per hour
b) Hydraulic Crane Operator 75 tons and under-$.75 per hour
c) Hydraulic Crane Operator over 75 tons-$1.00 per hour
d) Lattice Boom Crane Operator-$1.50 per hour
Crane operator with main boom and jib 300' or longer: $1.50 per hour above the group 1 rate. Crane operator with main boom and jib 400' or longer: $3.00 per hour above the group 1 rate.
PAID HOLIDAYS: New Year's Day, Memorial Day, Fourth of July, Labor Day, Thanksgiving Day and Christmas Day.
POWER EQUIPMENT OPERATOR CLASSIFICATIONS
GROUP 1: Crane operator with main boom and jib 400', 300', or 220' or longer. Tower crane operator with CCO certification for combined length of mast and boom 220' or longer
GROUP 2: Crane operator with main boom and jib 140' or longer, tower cranes (Operators without CCO certification, or less than 220' length), gantry crane, whirley derrick
GROUP 3: Regular equipment operator; crane, stiff leg derrick, scraper, dozer, grader, front end loader, hoist, job mechanic, concrete pump truck, hydro excavators
GROUP 4: Air tugger (single drum), material hoist, boiler operator, sweeping machine, winch truck, Bobcat and similar equipment, fork truck (over 20 ft. lift), elevators( when operated by an operating engineer
GROUP 5: Pump, 6 in. or over; Well points, freeze systems, boom truck (non-swinging); end dumps and laser/power screed; concrete wire saw (20 h.p. and over), brokk concrete breaker
GROUP 6: Air compressor, welder, generator, conveyor, pump under 6", grease person and fork truck (20 ft. lifting capacity or less when working on masonry work)
GROUP 7: Oiler, fire tender and heater operator
ENGI0324-029 10/01/2009
AREA 1: BAY, SAGINAW, TUSCOLA, HURON AND SANILAC COUNTIES
AREA 2: GENESEE, LAPEER AND ST. CLAIR COUNTIES
Power equipment operators -hazardous waste removal:
(AREA 1)
LEVEL A:
Engineer when operating crane with boom and jib or leads 140' or longer....$ 32.77 17.80 Engineer when operating crane with boom and jib or leads 220' or longer....$ 33.07 17.80
GROUP 1....................$ 30.12 17.80
GROUP 2....................$ 25.72 17.80
Regular crane operator, mechanic, dragline operator, boom truck operator, concrete pump with boom operator, Power Shovel Operator......$ 31.09 17.80
LEVEL B AND C:
Engineer when operating crane with boom and jib or leads 140' or longer....$ 31.71 17.80 Engineer when operating crane with boom and jib or leads 220' or longer....$ 32.03 17.80
GROUP 1....................$ 29.17 17.80
GROUP 2....................$ 24.78 17.80
Regular crane operator, mechanic, dragline operator, boom truck operator, concrete pump with boom operator, Power Shovel Operator............$ 30.14 17.80
LEVEL D WHEN CAPPING
LANDFILL:
Engineer when operating crane with boom and jib or leads 140' or longer....$ 30.27 17.80 Engineer when operating crane with boom and jib or leads 220' or longer....$ 30.57 17.80
GROUP 1....................$ 27.62 17.80
GROUP 2....................$ 23.23 17.80
Regular crane operator, mechanic, dragline operator, boom truck operator and concrete pump with boom operator, power shovel operators.....$ 28.59 17.80
LEVEL D:
Engineer when operating crane with boom and jib or leads 140' or longer....$ 30.52 17.80 Engineer when operating crane with boom and jib or leads 220' or longer....$ 30.82 17.80
GROUP 1....................$ 27.87 17.80
GROUP 2....................$ 23.48 17.80
Regular crane operator, mechanic, dragline operator, boom truck operator, concrete pump with boom operator, Power Shovel Operator............$ 28.84 17.80 Power equipment operators -hazardous waste removal:
(AREA 2)
LEVEL A:
Engineer when operating crane with boom and jib or leads 140' or longer....$ 34.48 17.80 Engineer when operating crane with boom and jib or leads 220' or longer....$ 34.78 17.80
GROUP 1....................$ 31.83 17.80
GROUP 2....................$ 27.60 17.80
Regular crane operator, mechanic, dragline operator, boom truck operator, power shovel operator, concrete pump with boom operator.........$ 32.80 17.80
LEVEL B AND C:
Engineer when operating crane with boom and jib or leads 140' or longer....$ 33.53 17.80 Engineer when operating crane with boom and jib or leads 220' or longer....$ 33.83 17.80
GROUP 1....................$ 30.88 17.80
GROUP 2....................$ 26.65 17.80
Regular crane operator, mechanic, dragline operator, boom truck operator, concrete pump with boom operator, power shovel operator............$ 31.85 17.80
LEVEL D WHEN CAPPING
LANDFILL:
Engineer when operating crane with boom and jib or leads 140' or longer....$ 31.98 17.80 Engineer when operating crane with boom and jib or leads 220' or longer....$ 32.28 17.80
GROUP 1....................$ 29.33 17.80
GROUP 2....................$ 25.10 17.80
Regular crane operator, mechanic, dragline operator, boom truck operator, concrete pump with boom operator, power shovel operator............$ 29.68 17.80
LEVEL D:
Engineer when operating crane with boom and jib or leads 140' or longer....$ 32.23 17.80 Engineer when operating crane with boom and jib or leads 220' or longer....$ 32.53 17.80
GROUP 1....................$ 29.58 17.80
GROUP 2....................$ 25.35 17.80
Regular crane operator, mechanic, dragline operator, boom truck operator, concrete pump with boom operator, power shovel operator............$ 30.55 17.80
HAZARDOUS WASTE REMOVAL CLASSIFICATIONS
GROUP 1: Backhoe, batch plant operator, clamshell, concrete breaker when attached to hoe, concrete cleaning decontamination machine operator, concrete pump, concrete paver, crusher, dozer, elevating grader, endloader, farm tractor (90 h.p. and higher), gradall, grader, heavy equipment robotics operator, loader, pug mill, pumpcrete machines, pump trucks, roller, scraper (self-propelled or tractor drawn), side boom tractor, slip form paver, trencher, ultra high pressure waterjet cutting tool system operator, vactors, vacuum blasting machine operator, vertical lifting hoist, vibrating compaction equipment (self- propelled), well drilling rig, slope paver and hydro excavator
GROUP 2: Air compressor, concrete breaker when not attached to hoe, elevator, end dumps, equipment decontamination operator, farm tractor (less than 90 h.p.), forklift, generator, heater, mulcher, pigs (portable reagent storage tanks), power screens, pumps (water), stationary compressed air plant, sweeper, welding machine and water wagon
ENGI0326-004 05/01/2009
Power equipment operators -gas distribution and duct installation work:
MACOMB, MONROE, OAKLAND,
ST. CLAIR, WASHTENAW and
WAYNE COUNTY:
GROUP 1....................$ 25.98 17.80
GROUP 2....................$ 25.85 17.80
GROUP 3....................$ 24.72 17.80
GROUP 4....................$ 24.15 17.80
REMAINDER OF COUNTIES:
GROUP 1....................$ 25.07 17.80
GROUP 2-A..................$ 24.97 17.80
GROUP 2-B..................$ 24.75 17.80
GROUP 3....................$ 23.97 17.80
GROUP 4....................$ 23.47 17.80
SCOPE OF WORK:
The construction, installation, treating and reconditioning of pipelines transporting gas vapors within cities, towns, subdivisions, suburban areas, or within private property boundaries, up to and including private meter settings of private industrial, governmental or other premises, more commonly referred to as "distribution work", starting from the first metering station, connection, similar or related facility, of the main or cross country pipeline and including duct installation.
POWER EQUIPMENT - GAS DISTRIBUTION CLASSIFICATIONS
Macomb, Monroe, Oakland, St.Clair, Washtenaw and Wayne:
GROUP 1: Backhoe, crane, grader, mechanic, dozer (D-6 equivalent or larger), side boom (D-4 equivalent or larger), trencher(except service), endloader (2 yd.
capacity or greater).
GROUP 2: Dozer (less than D-6 equivalent), endloader (under 2
yd. capacity), side boom (under D-4 capacity), backfiller, pumps (1 or 2 of 6-inch discharge or greater), boom truck (with powered boom), tractor (wheel type other than backhoe or front endloader).
GROUP 3: Tamper (self-propelled), boom truck (with non-powered boom), concrete saw (20 hp or larger), pumps (2 to 4 under 6-inch discharge), compressor (2 or more or when one is used continuously into the second day), trencher(service), GROUP 4: Oiler, hydraulic pipe pushing machine, grease person and hydrostatic testing operator.
REMAINDER OF COUNTIES:
GROUP 1: Mechanic, crane (over 1/2 yd. capacity), backhoe (over 1/2 yd. capacity), grader (Caterpillar 12 equivalent or larger)
GROUP 2-A: Trencher(except service), backhoe (1/2 yd.
capacity or less)
GROUP 2-B: Crane (1/2 yd. capacity or less), compressor (2 or more), dozer (D-4 equivalent or larger), endloader (1 yd.
capacity or larger), pump (1 or 2 six-inch or larger), side boom (D-4 equivalent or larger).
GROUP 3: Backfiller, boom truck (powered), concrete saw (20 hp or larger), dozer (less than D-4 equivalent), endloader (under 1 yd. capacity), farm tractor (with attachments), pump (2 - 4 under six-inch capacity), side boom tractor (less than D-4 equivalent), tamper (self-propelled), trencher(service) and Grader(maintenance).
GROUP 4: Oiler, grease person, hydrostatic testing operator
* IRON0025-005 06/01/2009
Rates Fringes
Ironworker - pre-engineered metal building erector...........$ 24.02 15.38
IRONWORKER
Ornamental & Structural.....$ 29.26 27.62 Reinforcing.................$ 26.83 24.26
LABO0005-012 10/01/2008
AREA 1: BAY, SAGINAW AND TUSCOLA COUNTIES
AREA 2: GENESEE AND LAPEER COUNTIES
AREA 3: ST. CLAIR COUNTY
Laborers - hazardous waste abatement:
AREA 1
Level A, B or C............$ 21.86 9.75 Work performed in conjunction with site preparation not requiring the use of personal protective equipment;
Also, Level D..............$ 20.86 9.75
AREA 2
Level A, B or C............$ 22.28 9.88 Work performed in conjunction with site preparation not requiring the use of personal protective equipment;
Also, Level D..............$ 21.28 9.88
AREA 3
Work performed inside the building and up to and including 5 ft. outside the building: (Work performed in conjunction with site preparation) not requiring the use of personal protective equipment; Also, Level D...$ 24.83 11.38 Work performed inside the building and up to and including 5 ft. outside the building: Level A, B or C.......................$ 25.83 11.38 Work performed over 5 ft.
outside the building:
(Work performed in conjunction with site preparation) not requiring the use of personal protective equipment; Also, Level D...$ 20.30 9.80 Work performed over 5 ft.
outside the building:
Level A, B or C............$ 21.30 9.80
LABO0259-010 08/01/2009
Rates Fringes
Asbestos Laborer Includes removing and disposing of all insulation materials from walls, ceilings, floors, columns, and all other non-mechanical surfaces; and removal of insulating materials from mechanical systems that are to be demolished;
loading/unloading of bagged and tagged materials at the disposal site (includes lead paint abatement clean-up).........$ 24.23 11.30
LABO0259-012 09/01/2009
Rates Fringes
Laborers - tunnel, shaft and caisson:
GROUP 1.....................$ 21.37 10.95
GROUP 2.....................$ 21.46 10.95
GROUP 3.....................$ 21.56 10.95
GROUP 4.....................$ 21.72 10.95
GROUP 5.....................$ 21.98 10.95
GROUP 6.....................$ 22.29 10.95
GROUP 7.....................$ 14.56 10.95
SCOPE OF WORK: Tunnel, shaft and caisson work of every type and descripton and all operations incidental thereto, including, but not limited to, shafts and tunnels for sewers, water, subways, transportation, diversion, sewerage, caverns, shelters, aquafers, reservoirs, missile silos and steel sheeting for underground construction.
LABORER CLASSIFICATIONS
GROUP 1: Tunnel, shaft and caisson laborer, dump, shanty, hog house tender, testing (on gas)
GROUP 2: Manhole, headwall, catch basin…
This is the start of the file's text. The full file is on GovTribe.