Technical_Exhibit_5.13-003_Building_100_Equipment.pdf

PDF 54 KB Posted

Attached to
Sources Sought - Fort Benning, GA Base Operations Federal contract opportunity
Solicitation number
W911SF-16-R-0012
Issued by
Department of the Army Materiel Command Mission and Installation Contracting Command Fort Benning

View the file

Other files for this federal contract opportunity

Other files attached to Sources Sought - Fort Benning, GA Base Operations, newest first.
File Type Posted
Special_Notice___Sources_Sought___Benning_BASOPS_20_Mar_18.docx DOCX document
Technical_Exhibit_5.13-007_Governmnet_Furnished_Property.docx DOCX document
TE_5.2-005-_Bldgs._Designated_for_Roof_Truss_Inspection.xls XLS spreadsheet
Technical_Exhibit_5.13-002a_Chiller_Data.docx DOCX document
TE_5.4-002a_Monthly_emergency_Hour-meter_Reading_Report.docx DOCX document
TE_1-011-_ASP_Identifications.xls XLS spreadsheet
TE_5.1-006_Variance_Report.xlsx XLSX spreadsheet
TE_5.2-006-_Roof_Truss_Inspection_Form.doc DOC document
TE_1-001_Fort_Benning_PRS.rtf RTF text file
TE_5.1-004_Master_Agreements_Register.xls XLS spreadsheet
TE_5.1-001-_Service_Order_(SO)_Workload_Summary.xls XLS spreadsheet
TE_5.4-006_Petroleum_Products_Issued.docx DOCX document
TE_5.4-003-_List_of_Fuel_Tanks.xls XLS spreadsheet
TE_5.2-025_List_of_Ranges,_Lighting_Protection_&_Grounding_Points.docx DOCX document
TE_5.4-002-_List_of_Emergency_Generators.xls XLS spreadsheet
TE_512_004_Work_Load_Data.xlsx XLSX spreadsheet
TE_5.2-016_-_Signal_Ground_Reference_Subsystem_Checklist_For_New_Facilities.docx DOCX document
TE_5.3-001_Inventory_Of_Dining_Facility_Equipment.xls XLS spreadsheet
TE_1-013_DPW__Network_Access.doc DOC document
TE_5.12-006a_Columbarian_Numbering.doc DOC document
TE_1-009-_List_of_Restricted_Areas.doc DOC document
Technical_Exhibit_5.13-004_Deliverables_Schedule.docx DOCX document
Technical_Exhibit_5.13-005_Operational_Inspection_Checklist.docx DOCX document
TE_5.2-027_Traffic_Light_Control_List.xlsx XLSX spreadsheet
TE_5.2-026_Mas_Fire_Alarm_Schedule_as_of_01April2013.xlsx XLSX spreadsheet
Attachment_2_-_Technical_Exhibits_Listing_16-R-0012_Benning_BASOPS.docx DOCX document
Attachment_7_-_Pricing_and_Labor_Matrix_16-R-0012_DPW_Benning_BASOPS_8_Aug_17.xlsx XLSX spreadsheet
Sec_C-5.10_REMOTE_CAMP_OPERATION_MAINTENANCE__SUPPORT.docx DOCX document
Sec_C-2_Definitions.docx DOCX document
Sec_C-5.1__TECHNICAL_DESCRIPTION_OF_WORK.doc DOC document
Attachment_5_-_Cover_Sheet_Past_Performance_Questionaire_DPW_Benning_BASOPS.pdf PDF
Sec_C-5.2_BUILDINGS_&_STRUCTURES_MAINTENANCE.doc DOC document
Technical_Exhibit_5.13-001_Chiller_Equipment.pdf PDF
TE_5.3-001-Inventory_of_Dining_Facility_Equipment.pdf PDF
TE_5.5-004-_List_of_Buildings_Requiring_Monthly_Filter_Chang.pdf PDF
TE_5.2-010-_Locations_of_Welcome_Home_Ceremony_Signs.pdf PDF
Technical_Exhibit_5.13-007_Governmnet_Furnished_Property.pdf PDF
TE_5.2-022_-_Shielding_Subsystem_Checklist_For_Existing_Facilities.pdf PDF
Sec_C-3_Government-Furnished_Property_and_Servicesb.pdf PDF
TE_5.7-002-_Street_Sweeping_Schedule.pdf PDF
TE_5.2-002-_List_of_Memorials.pdf PDF
TE_5.11-002-_Maintenance_Allocation_Chart.pdf PDF
Sec_C-5.2_BUILDINGS_ _STRUCTURES_MAINTENANCEb.pdf PDF
TE_5.5-003-_List_of_Building_Requiring_Changeover.pdf PDF
TE_5.9-001-_Recommended_Self-Help_Center_Stockage_List.pdf PDF
TE_5.11-004-_Obstacle_and_Confidence_Courses.pdf PDF
TE_5.11-003-_Range Service_Roads _Access_Grading_prioritizat.pdf PDF
TE_5.7-001-_Required_Scheduled_Tasks.pdf PDF
TE_5.2-006-_Roof_Truss_Inspection_Form.pdf PDF
TE_5.5-001-_Required_Scheduled_Tasks.pdf PDF
Show all 50

Sources Sought - Fort Benning, GA Base Operations has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Technical Exhibit 5.13-003

Building 100 Equipment

EQUIPMENT MANUFACTURER

MODEL

NO. REFRIG.

CAP.

TONS LOCATIONS

Evaporator Fan Coil Whitt SCDA270HA R-22 Butter Room Door # 2

Evaporator Fan Coil Whitt SCDA270HA R-22 Butter Room Door # 2

Evaporator Fan Coil Whitt SDE300LD R-404a Large Ice Storage Freezer Door 9

Condensing Unit # 1 Whitt DED22L44 R-404a @ 84 lbs 22 Front Mechanical Room Left side of Bldg.

Evaporator Fan Coil Whitt SDE300LD R-404a Large Ice Storage Freezer Door 9

Condensing Unit # 2 Whitt DED22L44 R-404a @ 84 lbs 22 Front Mechanical Room Left side of Bldg.

Evaporator Fan Coil Whitt SDE300LD R-404a Large Ice Storage Freezer Door 9

Evaporator Fan Coil Whitt SDE300LD R-404a Large Ice Storage Freezer Door 9

Evaporator Fan Coil Whitt SDE300LD R-404a Large Ice Storage Freezer Door 9

Evaporator Fan Coil Whitt SDE300LD R-404a Large Ice Storage Freezer Door 9

Cooling Tower Evapco LWR-18-12 Front Mechanical Room # 3 Right Side

Condenser Pump Taco FE1508-E2C-1-E-260A Front Mechanical Room # 3 Right Side

Evaporator Fan Coil Whitt SDE300LD R-404a Large Ice Storage Freezer Door 9

Evaporator Fan Coil Whitt SDE300LD R-404a Large Ice Storage Freezer Door 9

Evaporator Fan Coil Whitt SDE300LD R-404a Large Ice Storage Freezer Door 9

Evaporator Fan Coil Dunham-Bush ECE460 502 Small Ice Storage Area

Evaporator Fan Coil Dunham-Bush ECE460 502 Small Ice Storage Area

Evaporator Fan Coil Dunham-Bush ECE460 502 Small Ice Storage Area

Compressor Dunham-Bush EH151DPELF 502 6 Front Mechanical Room # Middle of Bldg.

Compressor Dunham-Bush EH151DPELF R-22 10 Front Mechanical Room # Middle of Bldg.

Evaporator Fan Coil Dunham-Bush ECE360 502 Small Ice Storage Area

Evaporator Fan Coil Dunham-Bush ECE360 502 Small Ice Storage Area

Water Source Heat Pump Trane GEHA02411A R-22 2 Dry Storage MRE

Heat Pump Trane GEHA02411A R-22 2 Dry Storage MRE

Water Source Heat Pump Trane GEHA02411A R-22 2 Dry Storage MRE

Water Source Heat Pump Trane GEHA02411A R-22 2 Dry Storage MRE

Water Source Heat Pump Trane GEHA02411A R-22 2 Dry Storage MRE

Water Source Heat Pump Trane GEHA02411A R-22 2 Dry Storage MRE

Water Source Heat Pump Trane GEHA00151A R-22 1.5 Dry Storage MRE

Water Source Heat Pump Trane GEHA00151A R-22 1.5 Dry Storage MRE

Water Source Heat Pump Trane GEHA02411A R-22 1.5 Dry Storage MRE

Water Source Heat Pump Trane GEHA02411A R-22 2.5 Dry Storage MRE

Technical Exhibit 5.13-003

Building 100 Equipment

EQUIPMENT MANUFACTURER

MODEL

NO. REFRIG.

CAP.

TONS LOCATIONS

Water Source Heat Pump Trane GEHA02411A R-22 2.5 Dry Storage MRE

Water Source Heat Pump Trane GEHA02411A R-22 2.5 Dry Storage MRE

Water Source Heat Pump Trane GEHA02411A R-22 2.5 Dry Storage MRE

Evaporator Fan Coil DeWitt DED22L44 R-404a

File details come from the government source that posted it. Updated .