Q and A Log SAM Posting.xlsx

XLSX spreadsheet 11 KB Posted

Attached to
Solicitation : Decontamination Kits [Multiple NSNs]
Solicitation number
W56HZV-21-R-0179
Issued by

View the file

Other files

File Type Posted
W56HZV-21-R-0179 29 August 2023.pdf PDF
W56HZV21R0179-0007.pdf PDF
W56HZV21R0179-0006.pdf PDF
Q and A Log SAM Posting.xlsx XLSX spreadsheet
W56HZV21R0179-0005.pdf PDF
Q and A Log SAM Posting.xlsx XLSX spreadsheet
W56HZV21R0179-0004.pdf PDF
Q and A Log SAM Posting.xlsx XLSX spreadsheet
W56HZV21R0179-0003.pdf PDF
W56HZV21R0179-0002.pdf PDF
Files to view 2D-3D Files.doc DOC document
Solicitation W56HZV-21-R-0179 26 July 2022.pdf PDF
W56HZV21R0179-0001.pdf PDF
Instructions to open Chemical TDPs.doc DOC document
Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

Q&A Log for Solicitation Posting W56HZV-21-R-0179
Item #QuestionGovernment Answer
1The requirements for USMC BAG 4 include the below hoses and connection but did not have any additional data package PDFs. We wanted to seek verification that the below products would be technically acceptable for our bid. Can you please advise if these would meet any requirements beyond the listed milspec?

Size 2 1/2 in(NH) x1 1/2 in(NH) Class C Type XV Fire and Water Hose Connection MIL-DTL-52404

Dixon Leader Line Wye ¼ Turn Ball Type Hose Valve, Part number LLBV2515F:Leader Line Wye 1/4 Turn Ball Type Hose Valve | Dixon (dixonvalve.com) < Caution-https://dixonvalve.com/en/products/leader-line-wye-14-turn-ball-type-hose-valve/llbv2515f > Dixon ¼ Turn Plug Type Wye Valve, Part Number S6175: 1/4 Turn Plug Type Wye Valve | Dixon (dixonvalve.com) < Caution-https://dixonvalve.com/en/products/14-turn-plug-type-wye-valve/s6175 >

100' Fire HoseAA59226 3 B 1.5 100
50' Fire HoseAA59226 3 B 1.5 50

300# Single Jacket All Plyester Fire Hose, Part Number A315-50RAF (and A315-100RAF):300# Single Jacket All Polyester Fire Hose | Dixon (dixonvalve.com) < Caution-https://dixonvalve.com/en/products/300-single-jacket-all-polyester-fire-hose/a315-50raf > The Dixon Wye valve indicated does not meet the technical criteria of MIL-DTL-52404 Type XV, Class C. Due to size constraints of the bag, the wye valve is too large for the components to fit.

The Dixon Fire Hose datasheet indicates that they do not meet the 600 Psig burst pressure requirement of A-A-59226. If hose can meet burst requirement and datasheet is incorrect, then it would meet the technical requirements.

For the MIL-DTL-52404 and A-A-59226 spec PDFs, they should be available at https://quicksearch.dla.mil/qsSearch.aspx

2I wanted to make sure before I look elsewhere for the bag. I have been in contact with The suggested source Fire Force Tactical and spoke with Brandy. The facility is closed down for the rest of the year and this bag is possibly being discontinued. My question is was this bag a source product to Fire Force Tactical for the bag or can I use another bag manufacture?The Government reached out to Fireforce and they stated the 1375-515 bag is still available in limited quantities and colors.
3I've reviewed the Q&A responses regarding the 1375-515 bag availability and understand that, per Fire Force, the bag is being phased out and the limited quantity available would be the bag count below leaving too few available for this solicitation. Fire Force also elaborated that no replacement has been in production. Can you advise if the government will be looking for a replacement to the the 1375-515 bag for this project?There is only one vendor on the dwg, so I do not know of a substitute for this particular bag but DRSKO does work with other bag vendors that I believe can match the particular specs on the drawing. The other bag company the Government works with is:

AVALON INDUSTRIES, INC.

2000 E WASHINGTON BLVD

BALTIMORE, MD 21230

CAGE: 64730

4 We found an issue with the technical requirements as cited in the Special Packaging Instructions for each of the kits.

For example, with SPI P1375-512:

reference page 2 of 5 for components:

1. Packing List (See Note 3 on drawing 1375-512), Quantity 1

Drawing 1375-512, Note 3 shows only:

INSERT PACKING LIST IN

MAIN COMPARTMENT’S TOP

ZIPPERED COMPARTMENT.

What requirements apply to the packing list itself? That is, what format/text etc will the government require? Please clarify.

This issue applies to all the NSN’s listed in the solicitation. Pending