About this file

This document provides details on storm water system maintenance requirements and a related federal contract opportunity. The storm water system consists of 666 inlets, 75 manholes, and over 104,000 feet of underground piping managing rainwater flows at Picatinny Arsenal. Proper maintenance practices include addressing problems promptly, scheduled maintenance, and security. All components must be inspected according to BMP protocols and reports furnished to the Department of Public Works.

The related solicitation is for base operations services at Picatinny Arsenal. Solicitation W15QKN-21-R-5005 will close on February 2, 2021 at 2:00 PM EST. The requirement is being issued by the Department of the Army Materiel Command Contracting Command located at Picatinny Arsenal.

View the file

Other files for this federal contract opportunity

Other files attached to Picatinny Arsenal Base Operations (BASOPS), newest first.
File Type Posted
W15QKN21R5005_Amendment 0006.docx DOCX document
W15QKN21R5005_Amendment 0005.docx DOCX document
011.1-USAG Picatinny VGSA-DD 254 Continuation Sheet.docx DOCX document
08.1-Davis Bacon Wage Determination-Building-REVISION 01 (NJ20210038-1 Jan 21).pdf PDF
7.6-LRC Picatinny Maintenance SOP 2020-NEW.pdf PDF
DD Form 1423-1-A041 (Scheduled Pest Inspections-Work)-NEW.pdf PDF
DD Form 1423-1-A039 (HVAC Emergency Personnel Roster)-NEW.pdf PDF
DD Form 1423-1-A036 (Quarterly Visual Insp Report)-NEW.pdf PDF
DD Form 1423-1-A026 (Quality Control Report)-NEW.pdf PDF
DD Form 1423-1-A013 (Damage Report)-REVISION 01.pdf PDF
DD Form 1423-1-A007 (Key Control)-REVISION 01.pdf PDF
DD Form 1423-1-A004 (Accident Reporting)-REVISION 01.pdf PDF
TE 2.5 IDS Zones by Bldg_Rev1.docx DOCX document
TE 2.2 Attachment A Equipment List_2020_Rev1.pdf PDF
7.5-Dispatching Procedures-NEW.pdf PDF
0004 Technical Exhibit List of Picatinny Historic Buildings Use and Distribution_Rev1.pdf PDF
012-CBA Wage Determination-DOL Cover Letter.pdf PDF
012.1-CBA-Picatinny_ 2018_2021.pdf PDF
09-Service Contract Act (SCA) Wage Determination-REVISION 01_20201221.pdf PDF
DD Form 1423-1-A042 (Pest Management License and Certifications)-NEW.pdf PDF
DD Form 1423-1-A035 (Wastewater and Storm Water Systems Safeguarding Plan)-NEW.pdf PDF
DD Form 1423-1-A031 (Storm Water Collection System Maint Work Plan)-NEW.pdf PDF
DD Form 1423-1-A024 (Disaster Contingency Plan)-NEW.pdf PDF
DD Form 1423-1-A022 (Real Property Records Updates)-NEW.pdf PDF
DD Form 1423-1-A019 (Records-All Monthly Maint Activity)-NEW.pdf PDF
DD Form 1423-1-A018 (Tree Srvc-Maint PMP)-NEW.pdf PDF
21R5005 BASOPS Consolidated QAs-20210315 (pricing) published.xls XLS spreadsheet
Picatinny_Arsenal_Site Visit_Vendor_Name (Rev1).xlsx XLSX spreadsheet
COVID19-Temperature-Symptom-Log.pdf PDF
Picatinny_Arsenal_Site Visit_Vendor_Name.xlsx XLSX spreadsheet
Gate Sign Revised to Questionnaire.docx DOCX document
02 - Past Performance Questionaire_Rev1.docx DOCX document
0002 - Technical Exhibits 2.1-2.9 (9 each) - GFP-GFE-GFM.zip ZIP file
0003.1 - Technical Exhibits 3.1-3.15 (15 each) - FMI w-Facilities & Structures.zip ZIP file
0004 - Technical Exhibit - List of Picatinny Historic Buildings-Use and Distribution.pdf PDF
0006.1 - Technical Exhibits 6.1-6.4 (3 each) - Facilities Management & Real Property Pubs.zip ZIP file
0006.2 - Technical Exhibits 6.5-6.11 (7 each) - Environmental #1.zip ZIP file
0006.3 - Technical Exhibits 6.12-6.15 (4 each) - HAZMAT & Solid Waste.zip ZIP file
0000 - General SOLICITATION Exhibits (10 each).zip ZIP file
0001.1 - CLS-408-Pavement Clearance.docx DOCX document
0003.2 - Technical Exhibits 3.16-3.19; 6.2 (5 each) - Storm Prep and Snow Removal.zip ZIP file
0003.4 - Technical Exhibits 3.30-3.32 (3 each) - GFEBS References.zip ZIP file
0003.5 - Technical Exhibit 33 - Picatinny Wellhead Protection Plan (Partial).pdf PDF
0006.5 - Technical Exhibits 6.17-6.18 (2 each) - Petroleum Fuel Activities & Internal Comb Engines.zip ZIP file
0006.6 - Technical Exhibits 6.19-6.34 (16 each) - Environmental #2.zip ZIP file
0006.7 - Technical Exhibits 6.35-6.42 (8 each) - Cultural & Historic Resource Management.zip ZIP file
0007 - Technical Exhibits 7.1-7.4 (4 each) - Safety PM (Fire-411-UPS-Elevators).zip ZIP file
0008 - Technical Exhibit - LIST OF GENERATORS FOR FUELING.XLS XLS spreadsheet
0013 - Technical Exhibit - Picatinny Integrated Nat Resource Mgmt Plan.pdf PDF
0015 - Technical Exhibit - Picatinny Arsenal Visitors Map.pdf PDF
Show all 50

Picatinny Arsenal Base Operations (BASOPS) has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Definition and Purpose:

The storm water system consists of 666 inlets, 75 manholes, and 104,195 linear feet of underground piping that manages the rainwater flows. The task is to provide correct BMP maintenance practices, operations, and repairs as identified by required BMP inspection protocols.

The goal is to make sure all components are functioning according to storm water criteria to divert water to inlets and identify areas of ponding or failure to flow properly. Testing for leaks to underground piping and integrity of manholes is part of the inspection and maintenance program

Approach:

The development and implementation of BMPs in order to insure they are being implemented, visual inspections and minor repairs will be performed periodically and during the course of the Stormwater System Maintenance Plan.

Existing and New Facilities:

When complaint investigations or routine stormwater audits for existing facilities indicate impacts to water resources due to poor management practices, DPW can take action to address any problems identified. Infrastructure and equipment, in addition to BMP implementation, are evaluated during inspections. To minimize the potential for compliance issues and to reduce liability, it is highly recommended that the recommendations in this document be followed.

Storm Water System - Inlets, Manholes, and Piping

U.S. ARMY, PICATINNY ARSENAL

PICATINNY, NEW JERSEY

STS System Operations and Maintenance

Many of the problems associated with STS systems involve proper grading and blockage of inlets which interfere with the property functioning of the STS system. The proper management and preventative maintenance practices for STS system will keep the system in good repair and will prevent water from ponding and damaging surrounding buildings and surface areas.

*These are the basic operation guidelines all STS system components must follow:

Inlets should be built and tested in accordance with industry and other specified standards

Manholes must be vented so fumes can escape, reducing the potential for ruptures and collapses.

Underground piping should be tested and inspected for leaks and structural issues.

To reduce the chances for failure, all STS system components should be tested and inspected using BMP criteria

All inlets, manholes and piping shall be labeled as to size and last internal inspection.

Make sure signs are visible and legible

Proper STS Maintenance Practices Include:

Good housekeeping: It is essential that the entire STS system be kept clean and free of any debris that will impeded the flow of the water to the inlets.

Address problems promptly: Make repairs are reported and initiated as soon as problems are noted.

Scheduled Maintenance: Scheduled maintenance should be performed on STS system along with inlets, manholes and underground piping. Any leaks should be addressed in a timely manner

Security: Any deficiencies, both physical and security oriented shall be re- mediated as soon as the deficiency is note

IMPORTANT: ALL Storm Water System components must be inspected and reports furnished to DPW.

Please contact DPW at

973-724-5952 to identify deficiencies in the STS system