SH
IP
R O C K C
O M P R
EH
EN
SI
VE
H
EA
LT
H C
A R E
FA
C
IL
IT
Y
N A
VA
JO
A
R
EA
I N D
IA
N H
EA
LT
H S
ER
VI
C E
SH
IP
R O C K
N
EW
M
EX
IC
O e B A
TO
L
R O
PA
N
IN
C.
A
RC
H
IT
EC
TU
RE
EN
GI
NE
ER
IN
G, NO
RT
H A
RC
AD
IA
AV
EN
UE
TU
CS
O N, A
RI
ZO
NA
AN
D
ER
O N D
S
Revisions Date
Checked By Drawn By Scale Project
0400.00
NONE
CONSTRUCTION DOCUMENTS
LMW/AGR
TAE
FEB. 1992
ONE LINE EMERGENCY
POWER RISER DIAGRAM
NORTH PORTION
E8.3
DSLAZHGENADSLAZHGENB
LOWER LEVEL
UC104
TVSS
DSLAZHGENB
TVSS
DSLAZHGENA
LA501Z
PULL
SECTION1200/3
ATS-4
NORMAL NORMAL
ATS-3 ATS-8
NORMAL
ATS-7
NORMAL
ATS-2
EQUIPMENT EQUIPMENT
ATS-9
CRITICAL
ATS-5
SAFETY
LIFE
ATS-6
SESLAZHNA
E8.1 E8.1
SESLAZHNA
E8.1
SESLAZHNB
E8.1
SESLAZHNB
E8.1
SESLAZHNA
E8.1
SESLAZHNB
E8.1
SESLAZHNA
E8.1
SESLAZHNA
NORTH AUTOMATIC
TRANSFER SWITCH
PRIORITY SCHEDULE
ATS-1 PRIORITY #5
PRIORITY #3ATS-2
PRIORITY #5ATS-3
PRIORITY #6ATS-4
PRIORITY #2ATS-5
PRIORITY #1ATS-6
PRIORITY #7ATS-7
PRIORITY #8ATS-8
PRIORITY #4
1000A 800A 800A 800A 800A 1000A 150A 150A
UCZHEA
PNL
UC501Z
XFMR
TUCZLEA
UC501Z
UC501Z
PNL
UCZLEA UCZLLA
PNL
UC501Z
UC501Z
TUCZLLA
XFMR
UC501Z
PNL
UCZHLA
3 #10, 1 #10 GRD, 3/4"C.
4 #6, 1 #8 GRD, 1-1/4"C.
MCCUCHE
UC501Z
CHILLER
CH-1
FIRE PUMP
CONTROLLER
DSLAZHNA
E8.1 E8.1
DPLAZHNA DSUCHNA
E8.1
DSLAZHNB
E8.1
PARALLEL 10 SETS
4 #600 MCM, 1#600 GRD., 4"C.
(10) 4"C., 50 CONDUCTORS
1 #500 MCM CU GRD
TO CONTERPOISE
TO COUNTERPOISE
1 #3/0 CU GRD
GEN #1 GEN #2
1200/3
LOWER LEVEL
LB125A
ELEVATOR #1
200/3/1/60
TDPLAZLCA
LA501Z
LAXLCA
PNL
LA503X
LA501Z
LA501Z
PNL
LAZHLA
XFMR
TLAYLLA
LA502Y
LA502Y
PNL
LAYLLA
LA503X
PNL
LAXLLA
LBZHLA
PNL
LB501Z
XFMR
TLBZLLA
LB501Z
LB501Z
PNL
LBZLLA
30/3/1/15
(4)#6, (1)#8 GRD, (1)1-1/4"C
1-1/4"C.
1 #10 GRD,
3/4"C.
1-1/4"C.
4 #6, 1 #8 GRD
GBZLLA
PNL
GB501Z
GB501Z
TGBZLLA
XFMR
GB503X
PNL
GBXHLA
GAYLLA
PNL
GA502Y
GAZLLA
PNL
GA501Z
GA501Z
TGAZLLA
XFMR
GAZHLA
PNL
GA501Z
GROUND LEVEL
GBZHLA
PNL
GB501Z
XFMR
TGAYLLA
GA502Y
GAYHLA
PNL
GA502Y
GA501Z
PNL
GAZLCA GAYLCA
PNL
GA502Y
GBWLCA
PNL
GB504W
LA501Z
TDPLAZLEA
LA502Y
PNL
LAYLEA LAXLEA
PNL
LA503X
LBZLEA
PNL
LB501Z
LBYLEA
PNL
LB502Y
LAZHEA
PNL
LA501Z
LBZHCA
PNL
LB501Z
LB116
PNL
DPLBMHEA
GBXLEA
PNL
GB503X GB501Z
PNL
GBZHEA
MCCPNHE
SECTION 1 SECTION 2
MCCPNHE
PH101
TPAZLEA
XFMR
PH101
PAZLEA
PNL
PH101
4 #6, 1 #8 GRD, 1-1/4"C.
DIST.
SWBRD
DSUCHEA
UC501Z
DPLAZLCA
PANEL
DIST.
3 #10, 1 #10 GRD
3/4"C.
PNL
LAZHCA
LA501Z
DIST.
PANEL
DPLAZLEA
LA501Z
DIST.
PANEL
DPLAZHLA
LA501Z LA501Z
DPLAZHCA
PANEL
DIST.
LA501Z
DPLAZHEA
PANEL
DIST.
ONE LINE EMERGENCY POWER RISER
DIAGRAM - NORTH PORTION N.T.S.
PENTHOUSE LEVEL
STEAM BOILER HPB-1.
SEE SHEET E3.2
LAZ501ZLAZ501ZLAZ501ZLAZ501ZLAZ501ZLAZ501ZLAZ501ZLAZ501Z
ELECTRICAL CONTRACTOR
TO MAKE ALL ELECTRICAL
CONNECTIONS FOR FIRE,
JOCKEY PUMPS PER
MANUFACTURES
SPECIFICATIONS
UC101
GROUND
NEUTRAL
1#500 MCM,
CU GRD. TO
COUNTERPOISE
IG
IG
NEUTRAL
GROUND
IG
NEUTRAL
GROUND
NOTE: ALL TRANSFER SWITCHES TO BE BRACED AT
65,000 RMS SYMMETRICAL AMPERES.
GFI
GFIGFIGFI
a 2500/3
4000/3
PARALLEL 4 SETS 4#350 MCM
1#3/0GRD. 4"C. (4) 4"C. 20
CODUCTORS.
AND
ATS-1
CABINET
LABEL "FIRE PUMP AUTOMATIC
TRANSFER SWITCH CONTROLLER"
'SESLAZHNB'-E8.1
ATS-9
PARALLELING GEAR
MANUFACTURERS ARE: POWER MEASUREMENTS LIMITED, WESTINGHOUSE
IMPAC IQ DATA PLUS TWO "GENERAL CONTRACTOR".
a
PARALLELING GEAR 480/277V.
3 PHASE 4WIRE 4000A. BUS
CONTROL CONDUITS FOR THE FOLLOWING:
(1) 1 1/2" CONDUIT REMOTE GENERATOR PANEL
(1) 2" CONDUIT LOOP CONTROL WIRING TO
AUTOMATIC TRANSFER SWITCHES ATS 1 THROUGH ATS 9.
(1) 1' CONDUIT TO FEUL STORAGE TANK ALARMS.
(1) 1" CONDUIT EACH TO TRANSFER PUMP/DAY TANK.
(1) 2" CONDUIT TO AMBULANCE EMERGENCY PARALLELING GEAR.
3 4"C W/4 500MCM & 1 2/0 GRD
3 4"C W/3 500MCM & 1 1/0 GRD
2-1/2"C W/4 1/0 & 1 #6 GRD
2-1/2"C W/4 4/0 & 1 #4 GRD
& 1 #2 GND TO
3-1/2"C W/3 500MCM
2-1/2"C
2 3-1/2"C W/4 350MCM & 1 1/0 GRD
2-1/2"C W/3 4/0 & 1 #4 GRD
1-1/2"C W/4 #2 & 1 #8 GRD
2-1/2"C W/3 4/0 & 1 #6 GRD
1-1/2"C W/4 #2 & 1 #8 GRD
3-1/2"C W/3 500MCM & 1 #2 GRD
2-1/2"C W/4 4/0 & 1 #6 GRD
1-1/2"C W/4 #2 & 1 #8 GRD
1-1/2"C W/4 #2 & 1 #8 GRD
1-1/2"C W/4 #2 & 1 #8 GRD
3 #10, 1 #10 GRD, 3/4"C
(3)3-1/2"C, (4)350MCM,
(1)1/0 GRD
(4)4"C, (4)4"C, (1)2/0 GRD
(4)350MCM,
(3)3-1/2"C, (4)4"C, (4)500MCM, (1)4/0 GRD
(3)1/0, (1)#6 GRD, (1)2"C.
(4)4/0, (1)#4 GRD, (1)2-1/2"C.
(4)#2, (1)#8 GRD, (1)1-1/2"C.
(3)350MCM, (1)1/0 GRD, (2)3"C.
(3)3/0, (1)#6 GRD, (1)2"C.
(4)#2, (1)#8 GRD, (1)1-1/2"C.
3 #10, (3)4/0, 1#6 GRD, 2-1/2"C
(3)500MCM, (1)#2 GRD, (2)3-1/2"C.