ConferenceRoom
| Letter | Description | Interfaces Type 1 | Interfaces Type 2 | Interfaces Type 3 | Interfaces Type 4 | Interfaces Type 5 | Interfaces Type 6 | Interfaces Type 7 | Comment | Comment 2 |
| A1 | Fliptop (with pullout cables, touch screen and cable retractors) installed on desk with the following interfaces: | 1 | 1 | Type 1 interfaces will be used to connect external laptops, tablets. Type 5 interfaces will be used to connect flash drives to the small factor pc that is in point B. | The cabling and ethernet connectors have to be PANDUIT CAT 6A whenever is possible (if not possible in one of the segments, offeror must provide reasons of why is not possible and provide proprietary equivalent), and must be cabled to the IDF (Location C). ILEA will connect this port to the access switches. The power outlets can use the same circuits that are below the table. The power outlets below the table must be eliminated and replaced with the same floor already used in that location (the company must consider these civil works). | |||||
| A2 | Fliptop (with pullout cables, touch screen and cable retractors) installed on desk with the following interfaces: | 1 | 1 | Type 1 interfaces will be used to connect external laptops, tablets. Type 5 interfaces will be used to connect flash drives to the small factor pc that is in point B. | The cabling and ethernet connectors have to be PANDUIT CAT 6A whenever is possible (if not possible in one of the segments, offeror must provide reasons of why is not possible and provide proprietary equivalent), and must be cabled to the IDF (Location C). ILEA will connect this port to the access switches. The power outlets can use the same circuits that are below the table. The power outlets below the table must be eliminated and replaced with the same floor already used in that location (the company must consider these civil works). | |||||
| A3 | Fliptop (with no touch screen, but with pullout cables, and cables retractors) installed on desk with the following interfaces: | 1 | This interfaces will be used to connect current IP Phones. | These two ethernet ports already exists below the table. The company must use these two ports and install them in this fliptop. The power outlets can use the same circuits that are below the table. The power outlets below the table must be eliminated and replaced with the same floor already used in that location (the company must consider these civil works). | ||||||
| B | Faceplate installed on wall (behind current smartboard) with the following interfaces: | 1 | 1 | 1 | A smartboard is installed in this location with a small factor PC behind it. The type 1 and 6 interfaces will connect to the small factor PC.The type 3 interfaces will connect the matrix to the smartboard. | The current power outputs and RJ45 interface in this location, have to be moved into this new faceplate (this applies to the type 1 interface). | ||||
| C | Video card with the following independent input: HDMI (1). Video card(s) with the following independent outputs: HDMI (2) and DisplayPort (2). Audio card(s) with the following independent outputs: : XLR (4), RJ45-Digital Audio-(2) | The main automation equipment (like the A/V Matrix) will be installed in a new rack located in this position. The HDMI input will be used to connect the digital set up box. The outputs will be used in other projects. | The IDF must be reorganized and a new rack must be provided by the company of the same model of the one currently installed in this position. | |||||||
| D | Faceplate installed on wall with the following interfaces: | 1 | This interface will be used by a bluray player. | |||||||
| E | Faceplate installed over the ceiling with the following interfaces: | 1 | This interfaces will be used by a projector installed on the ceiling. | |||||||
| F | This is the position where the Media presentation button panel and the lightining system will be located | |||||||||
| G | This is the position where the occuppancy sensor will be installed, in the center of the room. | |||||||||
| H | This is the position where the room scheduling screen will be installed. | |||||||||
| The position of the remaining items will be defined during the implementation. |
Breakout Rooms
| Letter | Description | Interfaces Type 1 | Interfaces Type 2 | Interfaces Type 3 | Interfaces Type 4 | Interfaces Type 5 | Interfaces Type 6 | Comment | Comment 2 |
| A | Fliptop (with pullout cables, touch screen and cable retractors) installed on podium with the interfaces type 1 and 5. The rest will be installed in the podium but not in the top. | 1 | 1 | 1 | 1 | The interfaces type 1 and 5 will be used to connect laptops, tablets, flash drives. The interfaces type 4 will be used to connect the gooseneck microphones. The type 3 interfaces will be used for a bluray player installed below the podium. The podium must be made according to the bluprints of the Presidential Lectern 2, nevertheless the company is able to suggest making changes on it for a better implementation... | The cabling and ethernet connectors have to be PANDUIT CAT 6A whenever is possible (if not possible in one of the segments, offeror must provide reasons of why is not possible and provide proprietary equivalent), and must be cabled to the IDF (room 2 and 3) and MDF (room 1). ILEA will connect this port(s) to the access switches. The company must provide a patch panel in case be needed. For the room 2 and 3, the IDFs must be reorganized so a new rack (provided by the company) fit that location, this new rack and cable organizers must be the same model of the one currently installed in this location. | ||
| B | Faceplate installed on wall (behind current smartboard) with the following interfaces: | 1 | 1 | 1 | A smartboard is installed in this location with a small factor PC behind it. The type 1 and 6 interfaces will connect to the small factor PC, the type 2 interfaces will connect to the smartboard. The current power outputs in this location have to be moved into this new faceplate. | The cabling and ethernet connectors have to be PANDUIT CAT 6A whenever is possible (if not possible in one of the segments, offeror must provide reasons of why is not possible and provide proprietary equivalent), and must be cabled to the IDF (room 2 and 3) and MDF (room 1). ILEA will connect this port(s) to the access switches. | |||
| C | Video card with the following independent input: HDMI (1). Audio card(s) with the following independent outputs: XLR (4), RJ45-Digital Audio-(2) | The A/V matrix will be installed in a rack located in this position. The HDMI input will be used to connect the digital set up box. The outputs will be used in other projects. | |||||||
| D | This is the position where the Media presentation button panel and the lightining system will be located | ||||||||
| E | This is the position where the occuppancy sensor will be installed, in the center of the room. | ||||||||
| The position of the room scheduling screen will be definied during the implementation . | |||||||||
| The position of the remaining items will be defined during the implementation. |
EventsHall
| Letter | Description | Interfaces Type 1 | Interfaces Type 2 | Interfaces Type 3 | Interfaces Type 4 | Interfaces Type 5 | Comment | Comment 2 |
| A | Faceplates installed on the wall, with the following interfaces: | 3 | 2 | 2 | 1 | 1 | Relatioship between faceplate and usage: 1. Type 1 - 3 PCs 2. Type 2 - interpretation and sound system 3. Type 3 - Monitors 4. Type 4 - Gooseneck microphones. 5. Type 5 - Bluray player. | |
| B | Faceplates installed on the wall, with the following interfaces: | 2 | Those interfaces will be used to input A/V signals from laptops, tablets. | |||||
| C | This is the position where the Touch Screen for General Use will be installed. Faceplates installed on the wall, with the following interfaces: | 1 | Those interfaces will be used to input A/V signals from laptops, tablets. | |||||
| D | Faceplates installed on the wall, with the following interfaces: | 1 | Those interfaces will be used to input A/V signals from laptops, tablets. | |||||
| E | Faceplates intalled on the floor (within a compartment that will be closed when not in use), with the following interfaces: | 1 | 1 | Relatioship between faceplate and usage: 1. Type 1 - Portable equipment. 2. Type 4 - Gooseneck microphones. | A movable podium will be used in this location when required. All cables will connect to the interfaces inside a box, that when closed, must protect the interfaces from liquid leaks, dust and damage from walking over it, the box must provide a lock mechanism. The podium must be made according to the bluprints of the Presidential Lectern 1, nevertheless the company is able to suggest making changes on it for a better implementation.. | |||
| F | Faceplates intalled on the floor (within a compartment that will be closed when not in use), with the following interfaces: | 1 | 1 | Relatioship between faceplate and usage: 1. Type 1 - Portable equipment. 2. Type 4 - Gooseneck microphones. | A movable podium will be used in this location when required. All cables will connect to the interfaces inside a box, that when closed, must protect the interfaces from liquid leaks, dust and damage from walking over it, the box must provide a lock mechanism. The podium must be made according to the bluprints of the Presidential Lectern 1, nevertheless the company is able to suggest making changes on it for a better implementation.. | |||
| G | Faceplates intalled on the floor (within a compartment that will be closed when not in use), with the following interfaces: | 1 | 1 | Relatioship between faceplate and usage: 1. Type 1 - Portable equipment. 2. Type 4 - Gooseneck microphones. | A movable podium will be used in this location when required. All cables will connect to the interfaces inside a box, that when closed, must protect the interfaces from liquid leaks, dust and damage from walking over it, the box must provide a lock mechanism. The podium must be made according to the bluprints of the Presidential Lectern 1, nevertheless the company is able to suggest making changes on it for a better implementation.. | |||
| H | Faceplates intalled on the floor (within a compartment that will be closed when not in use), with the following interfaces: | 1 | 1 | Relatioship between faceplate and usage: 1. Type 1 - Portable equipment. 2. Type 4 - Gooseneck microphones. | A movable podium will be used in this location when required. All cables will connect to the interfaces inside a box, that when closed, must protect the interfaces from liquid leaks, dust and damage from walking over it, the box must provide a lock mechanism. The podium must be made according to the bluprints of the Presidential Lectern 1, nevertheless the company is able to suggest making changes on it for a better implementation.. | |||
| M | Faceplates installed on the wall, with the following interfaces: | 1 | 2 | 1 | Relatioship between faceplate and usage: 1. Type 2 - Sound/Interpretation system. 2. Type 3 - Video monitors. 3. Type 4 - Interpretation microphones. | This is a interpretation booth. | ||
| N | Faceplates installed on the wall, with the following interfaces: | 1 | 2 | 1 | Relatioship between faceplate and usage: 1. Type 2 - Sound/Interpretation system. 2. Type 3 - Video monitors. 3. Type 4 - Interpretation microphones. | This is a interpretation booth. | ||
| O | Faceplate installed over the ceiling with the following interfaces: | 1 | This interfaces will be used by a projector installed on the ceiling. | The requested projector will be installed on this location. | ||||
| L | The requested motorized screen will be used for this location. | |||||||
| P | Faceplate installed over the ceiling with the following interfaces: | 1 | This interfaces will be used by a projector installed on the ceiling. | |||||
| Q | Video card with the following independent input: HDMI (1). Video card(s) with the following independent outputs: HDMI (4) and DisplayPort (4). Audio card(s) with the following independent outputs: : XLR (4), RJ45-Digital Audio-(2) | The A/V matrix will be installed in a rack located in this position. The HDMI input will be used to connect the digital set up box. The outputs will be used in other projects. | ||||||
| S | This is the position where the Media presentation button panel and the lightining system will be located. | |||||||
| T | This is the position where the second touch Screen for General Use will be installed | |||||||
| The position of the four occuppancy sensors will be defined during the implementation . | ||||||||
| The position of the two room scheduling screens will be defined during the implementation . | ||||||||
| The position of the remaining items will be defined during the implementation. |
Classrooms
| Letter | Description | Interfaces Type 1 | Interfaces Type 2 | Interfaces Type 3 | Interfaces Type 4 | Comment | Comment 2 |
| A | Interfaces installed on desk with the following interfaces (see comments to more information about the distribution): | 3 | 2 | Relatioship between faceplate and usage: 1. Type 1 - 3 PCs 2. Type 2 - 1 Object camera. 1 Bluray. The desk must be made according to the bluprints of the desk, nevertheless the company is able to suggest making changes on it for a better implementation. | How each interface will be installed (see desk for classrooms diagram): 1. Type 1. (1) Installed in a fliptop with touch screen, pullout cables and cables retractors. (2) Installed below the desk (center) for two desktops in form of a faceplate. 2. Type 2. (1) Installed in a fliptop with no touch screen but with pullout cables, and cable retractors for an object camera. (1) Installed below the desk (right) in the form of a faceplace for a bluray. The additional ethernet points must be cabled to the IDFs of the same level (the same that the breakout rooms will use). And must be PANDUIT CAT 6A (including accesories). | ||
| B | Fliptop (with touch screen, pullout cables and cable retractors) installed on desk with the following interfaces: | 1 | This interfaces will be used to send A/V signals from a PC in the equipment room. | ||||
| C | Fliptop (with touch screen, pullout cables and cable retractors) installed on desk with the following interfaces: | 1 | This interfaces will be used to send A/V signals from a laptop or tablet in the instructors booth. | ||||
| R | Faceplate installed on wall with the following interfaces: | 1 | 2 | The type 4 interfaces will be used to connect to the current audio mixer and future digital audio processor. The type 3 interfaces will be used to connect a monitor. | |||
| K | Video card with the following independent inputs: HDMI (1), DisplayPort (1) and VGA (1). Video card(s) with the following independent outputs: HDMI (4) and DisplayPort (4). Audio card(s) with the following independent outputs: XLR (2), RJ45-Digital Audio-(1) | The main automation equipment will be installed in a new rack located in this position, that will be provided by the company and must be the same model of the one currently installed in the IDF of each level. These inputs and outputs will be used in other projects. | |||||
| X | Faceplate installed on the wall with the following interfaces: | 2 | These interfaces will be used to connect monitors. | ||||
| Y | Faceplate installed on the wall with the following interfaces: | 2 | These interfaces will be used to connect monitors. | ||||
| Z | Faceplate installed on the wall with the following interfaces: | 2 | These interfaces will be used to connect monitors. | ||||
| P | Faceplate installed on the wall with the following interfaces: | 1 | These interfaces will be used to connect a monitor for the instructor. | ||||
| Q | Faceplate installed over the ceiling with the following interfaces: | 1 | This interfaces will be used by a projector installed on the ceiling. | ||||
| T | This is the position where the Media presentation button panel and the lightining system will be located. | ||||||
| The position of the two occuppancy sensors will be defined during the implementation . | |||||||
| The position of the room scheduling screen will be definied during the implementation . | |||||||
| The position of the remaining items will be defined during the implementation. |