SPECS 14 X 24 STORAGE BUILDING.docx

DOCX document 15 KB Posted

Attached to
UTILITY/STORAGE BUILDING D33Bid Documents
Solicitation number
00100-0000088048
Issued by
Marion County, Indiana

About this file

This is a specifications document for a utility/storage building project. The project calls for the construction of a single 14-foot by 24-foot portable storage building with specific structural and material requirements. The building shall feature 2x4 treated wall studs spaced 16 inches on center, metal siding and roofing in a color to be determined at a later date, and gable vents positioned in both the front and rear. The building will be equipped with an 8-foot by 7-foot insulated roll-up garage door on the front facade. The foundation shall consist of 2-inch by 6-inch treated floor joists spaced 12 inches on center with Advantech flooring boards. Insulation is specified for the roof, sides, and floor, though the R-value is not fully detailed in the document.

No specific pricing information, contract terms, timeline, response dates, or award details are included in this specifications document. The document does not identify the procuring agency, consortium, or jurisdiction, nor does it contain information regarding set-asides, funding sources, or contract duration. This appears to be a technical specifications sheet intended to serve as a basis for bidding or construction guidance.

View the file

Other files

File Type Posted
Notice of Addendum.pdf PDF
BID INSTRUCTIONS FOR SOURCING EVENT 0000088048.docx DOCX document
SOURCING EVENT PAPGES 88048.pdf PDF
EVENT PAGES FOR 88048.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SPECS FOR

14 X 24 UTILITY/STORAGE BUILDING

· Shall be 14’X 24’ utility/portable building

· Shall have 2x4 treated wall studs (16” On Center)

· Shall have metal siding and roof (color to be detrained later)

· Shall have a gable vent in the front and rear of building

· Shall have a 8’x7’ Insulated Roll-up Garage Door on the front of building

· Shall have 2”x6” treated floor joist (12” On Center)

· Shall have Advantech ¾” flooring boards

· Shall have ½” insulation in the roof, sides and floor

File details come from the government source that posted it. Updated .