(12)_Attachment_L_Drawings.pdf

PDF 10 MB Posted

Attached to
Site-Wide Replacement of Utility Poles Federal contract opportunity
Solicitation number
SP3300-17-B-0006
Issued by
Defense Logistics Agency Distribution

About this file

(12) Attachment L Drawings

View the file

Other files for this federal contract opportunity

Other files attached to Site-Wide Replacement of Utility Poles, newest first.
File Type Posted
Amendment_0005.pdf PDF
Amendment_0004.pdf PDF
Amendment_0003.pdf PDF
Amendment_0003_attachments.pdf PDF
Amendment_0002.pdf PDF
Amendment_0001.pdf PDF
Revised_Dwg_ES-101_&_ES-108-_Amendment_0001.pdf PDF
Site_Visit_Notes.pdf PDF
(10)_Attachment_J_Wage_Determinations.pdf PDF
(2)_Attachment_B_Short_Form_Badge_Request.pdf PDF
(6)_Attachment_F_DLA_SP_Camera_Pass_Request_Form.pdf PDF
(5)_Attachment_E_Deliv_Notification_Form.docm DOCM document
(7)_Attachment_G_SF24_-_Bid_Bond.pdf PDF
(8)_Attachment_H_SF25_(Performance_Bond).pdf PDF
SP3300-17-B-0006.pdf PDF
(3)_Attachment_C_Long_Form_Badge_Request.pdf PDF
(4)_Attachment_D_Badge_Renewal.doc DOC document
(1)_Attachment_A_New_Personnel_Notification_Form.docm DOCM document
(9)_Attachment_I_SF25A_(Payment_Bond).pdf PDF
(11)_Attachment_K_Project_Specifications_and_Submittals.pdf PDF
Show all 20

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ONeillJ1

RFA DLA

kingjw Text Box kingjw kingjw kingjw kingjw kingjw kingjw kingjw

ONeillJ1

RFA DLA

kingjw kingjw kingjw kingjw kingjw kingjw kingjw kingjw kingjw kingjw kingjw

PROVIDE WATER AND UV RESISTANT POLE TOP COVER.

NEW WOOD GUY POLE; SEE POLE CLASS AND HEIGHT IN POLE SCHEDULE.

SECONDARY/STREETLIGHT POWER CABLES.

15 KV FEEDER TERMINATION OR MOUNTING HEIGHT OF FEEDER CABLES.

NEW GUY CABLE WITH POLE ATTACHMENT HARDWARE. GUY SHALL BE INSTALLED

APPROXIMATELY 36" BELOW THE ACTIVE 12.47 KV CABLES AND ABOVE LOW VOLTAGE AND

SIGNAL CABLING. A GROUND ROD AND #6 AWG BARE CONDUCTOR SHALL BE INSTALLED AT

EACH DISTRIBUTION POLE WHERE NEW GUYING IS NOTED TO BOND THE GUY CABLE,

HARDWARE, EQUIPMENT, METALLIC SURFACES, AND MESSENGER CABLE ROUTED WITH THE

MV CABLES.

GUY CABLE ANCHOR SHALL BE INSTALLED AT APPROXIMATELY AT EQUAL DISTANCE FROM

POLE AS HEIGHT ABOVE GRADE. IF SUCH SPACING CANNOT BE ACCOMPLISHED THEN

SUPPORT ARM CAN BE USED TO SHORTEN THE HORIZONTAL DISTANCE FROM THE POLE.

REFER TO SPECIFICATION 337101 FOR DEPTH OF NEW GUY POLES BELOW GRADE AND FOR

RATINGS, TYPE, AND GUYING REQUIREMENTS. PROVIDE SHIELDS FOR GUYING TO GRADE, AS

OUTLINED IN SPECIFICATIONS.

LOW VOLTAGE, IT, TELECOM, CATV AND SECURITY CABLING ON POLES.

GUY POLE INSTALLATION DETAIL

NOT TO SCALEE-401

JO AA ?

E-401

JO

P O

LE

S

C H

E D

U

LE

SH

EE

T

D R

A W

N

BY

D E

S

IG

N

BY

S B

M T

BY

S

IZ

E:

FI

LE

N

AM

E:

IS

S

U E

D

AT

E:

C O

N

TR

AC

T

N O

S O

LI

C

IT

A

TI

O

N N

O

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C

KD

B Y:

US Army Corps of Engineers ®

"x

A

FI

LE

N U

M

BE

R

P

LO

T S

C

AL

E:

P

LO

T D

AT

E:

/3

1/

CHARLESTON DISTRICT

C H

A R

LE

S

TO

N

D

IS

TR

IC

T C

H A

R

LE

S

TO

N ,S

O U

TH

C

AR

O

LI

N

A

JA

C

O

BS

N O

R

TH

G

LE

B E

R O

AD

,S

U

IT

E

A

R

LI

N G

TO

N

,V A

D

EF

EN

SE

D

IS

TR

IB

U

TI

O N

C E

N

TE

R S

U S

Q U

EH

AN

N A

N E

W C

U M

B E

R

LA

N D

,P A

S

IT

E -W

ID

E

R E

PL

AC

EM

EN

T O

F U

TI

LI

TY

PO

LE

S

A

PP

R M

AR

K

D

AT

E A

PP

R

/3

1/

7:

A M

2 3 4 5

B

C

D

D

AT

E D

ES

C

R

IP

TI

O

N D

ES

C

R

IP

TI

O

N M

AR

K

NOTES

THE "DEMOLITION" SCHEDULE HAS BEEN PROVIDED TO LIST WHICH POLES SHOWN

ON THE SITE PLANS ARE TO BE REMOVED. THIS SCHEDULE PROVIDES A BRIEF

DESCRIPTION OF THE SERVICES THAT EXIST ON THE POLE FOR PURPOSES OF

BIDDING. THE PLANS DETAIL WHAT IS REQUIRED AT EACH POLE AND SHOULD BE

USED FOR APPROXIMATE DISTANCES, ETC. WHERE CABLING AND LOW VOLTAGE

SERVICES ARE NOTED TO BE REMOVED.

THE NEW POLE AND EQUIPMENT SCHEDULE INDICATES THE EXISTING POLES THAT

ARE TO BE DISCONNECTED, REMOVED, AND REPLACED WITH A NEW POLE AT

APPROXIMATELY THE SAME LOCATION. SITE PLANS GO INTO SPECIFIC DETAIL OF

THE EQUIPMENT AND SERVICES TO BE REMOVED; EQUIPMENT TO BE TAKEN DOWN

AND REINSTALLED, AND WHAT IS REQUIRED AT THE NEW "REPLACEMENT" POLE.

THERE ARE TYPICAL POLE DETAILS THAT PROVIDE GUIDANCE TO THE NEW POLE

INSTALLATION AND SERVICES NOTED. REFERENCE TO THOSE TYPICAL DETAILS ARE

MADE IN THE SCHEDULE. DETAILS INDICATE INFORMATION ABOUT ALL POSSIBLE

COMBINATIONS OF SERVICES THAT MAY EXIST, BUT THE SITE PLAN NOTES SHOULD

BE THE BASIS OF SPECIFIC POLE EFFORT. NOT ALL SERVICES EXIST AT THE POLE.

POLE HEIGHT, CLASS INDICATED IN THIS SCHEDULE ARE SPECIFIC TO THE

REQUIRED POLE AT THE LOCATION ON THE PLANS. SPECIFICATIONS TECHNICALLY

ADDRESS EQUIPMENT, INSTALLATION, TESTING, ETC.

POLE NA30 IS INCLUDED IN THE NEW WORK SCHEDULE BECAUSE SPECIFIC WORK IS

REQUIRED AT THAT POLE, HOWEVER, THE EXISTING WOOD POLE IS TO REMAIN IN

PLACE AT THE COMPLETION OF WORK.

ONeillJ1

RFA DLA

kingjw

File details come from the government source that posted it. Updated .