Section L Appendix 3 - Pre-Proposal Inquiry Form.xlsx
XLSX spreadsheet 14 KB Posted
- Attached to
- Safety and Reliability Upgrade, KSC Institutional Power Systems, Phase 4. Federal contract opportunity
- Solicitation number
- 80KSC021R0023
About this file
This document is a solicitation for a construction project for Safety and Reliability Upgrades to the Kennedy Space Center Institutional Power Systems, Phase 4. The project involves replacing five existing 15kV Load Break Switches and Vacuum Fault Interrupters located at various KSC locations, and replacing two aging substations in Operations Support Building 1 with new customized substations featuring switchgears, transformers, Load Break Switches, Vacuum Fault Interrupters, PLCs, equipment racks, and control and power wiring. Abatement procedures will be required for certain construction activities due to coatings containing asbestos, heavy metals, and PCBs on existing equipment. The period of performance is 730 calendar days with an anticipated award amount between $1,000,000 to $5,000,000. This small business set-aside opportunity is issued by NASA at the Kennedy Space Center under NAICS code 237130 with a size standard of $39.5 million.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment 06 signed.pdf | ||
| Amendment 05 signed.pdf | ||
| Amendment 04 signed.pdf | ||
| Amendment 03 signed.pdf | ||
| Amendment 02 signed.pdf | ||
| Amendment 01 signed.pdf | ||
| Attachment J-C Wage Determination FL20210001 Mod 3.pdf | ||
| Attachment J-D Certification of Progress Payments.doc | DOC document | |
| 80KSC021R0023 - RFP.pdf | ||
| Section L Appendix 1 - KSC Form 28-889 Visitor Badge Request.pdf | ||
| Section L Appendix 4 - Past Performance Questionnaire.docx | DOCX document | |
| Attachment J-A Project Deliverables.pdf | ||
| Attachment J-B KSC Project Specific Requirements.pdf | ||
| Section L Appendix 2 - Acceptable Identity Guide.docx | DOCX document | |
| Section L Appendix 5 - Badging Request Form (Secure Area).docx | DOCX document |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| No. | Date | Contractor Name | Reference | |
| (Section Paragraph/Page) | QUESTION | |||
| 1 | ||||
| 2 | ||||
| 3 | ||||
| 4 | ||||
| 5 | ||||
| 6 | ||||
| 7 | ||||
| 8 | ||||
| 9 | ||||
| 10 | ||||
| 11 | ||||
| 12 | ||||
| 13 | ||||
| 14 | ||||
| 15 | ||||
| 16 |
&"-,Bold"&12SOLICITATION NUMBER: 80KSC021R0023 PROJECT TITLE: Safety and Reliability Power Upgrades, Phase 4 &"-,Bold"&12SECTION L - APPENDIX 3&"-,Regular" &"-,Bold"PRE PROPOSAL INQUIRY FORM&"-,Regular"&9 &"-,Bold"&12Page &P of &N