This document set comprises technical design drawings and specifications for the City of Royal Oak's Network Cabling Upgrade and Demolition project at the Royal Oak Public Library. The project encompasses network cabling infrastructure improvements and demolition activities across the library's lower level and main level, as detailed in four interconnected design sheets (LL-TD-102, LL-T-102, ML-TD-101, and ML-T-101). The scope includes removal and disposal of obsolete telephone equipment such as 66 blocks and surface-mounted telephone back boxes, demolition of existing cabling from source locations, installation of new CAT 6A cabling, wireless access points (WAPs), and associated network infrastructure components. The drawings indicate multiple network drop categories: internal network drops (purple jacks and wire), building systems network drops (blue jacks and wire), and public network drops (orange jacks and wire). Electronic proposals must be submitted through the City of Royal Oak's procurement portal at https://procurement.opengov.com/portal/romi with a deadline of 3:00 pm on Monday, March 16, 2026.
The design documentation prepared by Convergent Technology Partners specifies critical coordination requirements, particularly regarding systems that cannot be interrupted without prior approval from the Owner and relevant service providers. New CAT 6A cabling serving the Sonitrol Alarm System and Fire Alarm Control Panel (FACP) requires coordination and approval before disconnection, relocation, or cutover to prevent loss of alarm monitoring and ensure compliance with applicable fire codes and Authority Having Jurisdiction (AHJ) requirements. The project includes field verification of exact mounting heights, routing, and termination points prior to installation. The City of Royal Oak reserves the right to reject any or all proposals, waive informalities, and accept proposals deemed most favorable to the City's interests, with unit prices governing in cases of pricing errors or arithmetical discrepancies.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BENCH
2 2
WAP
2-FB 2-FB 2-FB
2-FB
WAP
2 2
2 2
WAP
WAP
RISER_UP
RISER_UP
MDF CABINET
NEW
CAB-02
CABINET
EXISTING
CAB-01
JB
JB-01
EXISTING EMT
Remove and dispose of existing obsolete telephone equipment at this location, including but not limited to 66 block and associated surface-mounted telephone back boxes, as part of the overall wiring demolition scope.
Coordinate demolition with Owner.
Verify that equipment is abandoned prior to removal.
Remove and dispose of existing obsolete telephone equipment at this location, including but not limited to 66 block and associated surface-mounted telephone back boxes, as part of the overall wiring demolition scope.
Coordinate demolition with Owner.
Verify that equipment is abandoned prior to removal.
Demolish existing cabling from the source location to this point.
The user-end termination is concealed below finished flooring and is not accessible. Contractor shall remove cabling as close to the user-end termination as practical without disturbing finished surfaces.
Coordinate demolition limits with Owner.
C O N V E R G E N T 6197 Miller Road Suite 4 Swartz Creek, MI 48473
Phone: 810.720.3820 www.ctpartners.net
T E C H N O L O G Y P A R T N E R S
TECHNOLOGY DESIGN I CONSULTING I PLANNING
2/16/2026 FINAL KSR
2/11/2026 CLIENT REVIEW KSR
DATE ISSUE AUTHOR
LL-TD-102
LEGEND
CABINET
JB
JB-#
DESCRIPTION
EXISTING RISER UP
EXISTING RISER DOWN
ACCESS POINT DROP IN SURFACE MOUNT BOX.
PURPLE JACK AND WIRE
INTERNAL NETWORK DROP AND COUNT.
BLUE JACK AND WIRE
BUILDING SYSTEMS NETWORK DROP AND COUNT.
GRAY JACK AND WIRE
PUBLIC NETWORK DROP AND COUNT.
ORANGE JACK AND ORANGE OR WHITE WIRE
DEMO DROP TO SOURCE AND COMPONENTS
SURFACE MOUNT BOX
EXISTING TECHNOLOGY POLE - RACEWAY
EXISTING FLOOR BOX
EXISTING JUNCTIION BOX
4 POST ENCLOSED EQUIPMENT CABINET
FB_01
POWER_POLE
SMB-01
DEMO-01
N#
N#
N#
WAP_SMB_01
RISER_DOWN
RISER_UP
ROYAL OAK PUBLIC LIBRARY
NETWORK CABLING DEMOLITION
LOWER LEVEL
P2 P2
N2
N3
N2
N2
N3, P1
N2
N2
N2
N1, P1
N2 N2 N2
N2
N2
N2
N2
N2
N2
N2
N2
N2
N2
N2
N2
N1
N1, P1
N1, P1
P4P1
P1
P1
P1
P1 P1
P1 P1
P1
P1
P1
P1
RISER_UP
RISER_UP
P1
EXISTING EMT TO BE
REUSED
EXISTING EMT TO BE
REUSED
MDF CABINET
NEW
CAB-02
CABINET
EXISTING
CAB-01
JB
JB-01
N1
POWER_POLE POWER_POLE
Provide (1) single-gang box with
(1) vertical EMT conduit stub at this location.
Work is required. Exact mounting height, routing, and termination shall be field verified and coordinated prior to installation.
P2 P2
P2P2
WAP_SMB_W1
WAP_SMB_W1
WAP_SMB_W1
WAP_SMB_W1
WAP_SMB_W1
N2
N2
N2
C O N V E R G E N T 6197 Miller Road Suite 4 Swartz Creek, MI 48473
Phone: 810.720.3820 www.ctpartners.net
T E C H N O L O G Y P A R T N E R S
TECHNOLOGY DESIGN I CONSULTING I PLANNING
2/16/2026 FINAL KSR
2/11/2026 CLIENT REVIEW KSR
DATE ISSUE AUTHOR
LL-T-102
LEGEND
CABINET
JB
JB-#
DESCRIPTION
EXISTING RISER UP
EXISTING RISER DOWN
ACCESS POINT DROP IN SURFACE MOUNT BOX.
PURPLE JACK AND WIRE
INTERNAL NETWORK DROP AND COUNT.
BLUE JACK AND WIRE
BUILDING SYSTEMS NETWORK DROP AND COUNT.
GRAY JACK AND WIRE
PUBLIC NETWORK DROP AND COUNT.
ORANGE JACK AND ORANGE OR WHITE WIRE
DEMO DROP TO SOURCE AND COMPONENTS
SURFACE MOUNT BOX
EXISTING TECHNOLOGY POLE - RACEWAY
EXISTING FLOOR BOX
EXISTING JUNCTIION BOX
4 POST ENCLOSED EQUIPMENT CABINET
FB_01
POWER_POLE
SMB-01
DEMO-01
N#
N#
N#
WAP_SMB_01
RISER_DOWN
RISER_UP
ROYAL OAK PUBLIC LIBRARY
NETWORK CABLING UPGRADE
LOWER LEVEL
1-FB 1-FB
1-FB 1-FB
1-FB
1-FB
1-FB
1-FB
1-FB 1-FB
1-FB 1-FB
1-FB 1-FB
1 WAP
1 WAP
1-FB 1-FB
P1
1-WAP
1-FB 1-FB
12 2
2 2
1 WAP
2-FB
1-FB
1-FB
1 WAP
RISER_DOWN
RISER_DOWN
C O N V E R G E N T 6197 Miller Road Suite 4 Swartz Creek, MI 48473
Phone: 810.720.3820 www.ctpartners.net
T E C H N O L O G Y P A R T N E R S
TECHNOLOGY DESIGN I CONSULTING I PLANNING
2/16/2026 FINAL KSR
2/11/2026 CLIENT REVIEW KSR
DATE ISSUE AUTHOR
ML-TD-101
LEGEND
CABINET
JB
JB-#
DESCRIPTION
EXISTING RISER UP
EXISTING RISER DOWN
ACCESS POINT DROP IN SURFACE MOUNT BOX.
PURPLE JACK AND WIRE
INTERNAL NETWORK DROP AND COUNT.
BLUE JACK AND WIRE
BUILDING SYSTEMS NETWORK DROP AND COUNT.
GRAY JACK AND WIRE
PUBLIC NETWORK DROP AND COUNT.
ORANGE JACK AND ORANGE OR WHITE WIRE
DEMO DROP TO SOURCE AND COMPONENTS
SURFACE MOUNT BOX
EXISTING TECHNOLOGY POLE - RACEWAY
EXISTING FLOOR BOX
EXISTING JUNCTIION BOX
4 POST ENCLOSED EQUIPMENT CABINET
FB_01
POWER_POLE
SMB-01
DEMO-01
N#
N#
N#
WAP_SMB_01
RISER_DOWN
RISER_UP
ROYAL OAK PUBLIC LIBRARY
NETWORK CABLING DEMOLITION
MAIN LEVEL
N2
N2 P1, N1
P2
P2
P3
P1
P1
P1
P1
P6
P1, N1
N2
RISER_DOWN
RISER_DOWN
SMB-B2,N2
FB_P1
P1
P1
WAP_SMB_W1
WAP_SMB_W1
WAP_SMB_W1
WAP_SMB_W1
P1, N1
N2
N1
N4
N3
P1
N4
N1
N2
N3
P1
P1
New CAT 6A cabling serving the Sonitrol Alarm System shall NOT be disconnected, relocated, or cut over without prior coordination and approval from the Owner and Sonitrol Monitoring Provider.
Any interruption to this system may result in loss of alarm monitoring. Coordinate all work and cutover scheduling in advance.
N2
N2
N4
N2
N1
N2
N2
N1
N2
N2
B1
N2
B1 New CAT 6A cabling serving the Fire Alarm Control Panel (FACP) shall NOT be disconnected, relocated, or cut over without prior coordination and approval from the Owner and the Fire Alarm
Contractor.
System downtime is not permitted without an approved outage plan.
All work shall comply with applicable codes and AHJ requirements.
N2
WAP_SMB_W1
P1, N1
P1, N2
P1, N2
WAP_SMB_W1
WAP_SMB_W1
C O N V E R G E N T 6197 Miller Road Suite 4 Swartz Creek, MI 48473
Phone: 810.720.3820 www.ctpartners.net
T E C H N O L O G Y P A R T N E R S
TECHNOLOGY DESIGN I CONSULTING I PLANNING
2/16/2026 FINAL KSR
2/11/2026 CLIENT REVIEW KSR
DATE ISSUE AUTHOR
ML-T-101
LEGEND
CABINET
JB
JB-#
DESCRIPTION
EXISTING RISER UP
EXISTING RISER DOWN
ACCESS POINT DROP IN SURFACE MOUNT BOX.
PURPLE JACK AND WIRE
INTERNAL NETWORK DROP AND COUNT.
BLUE JACK AND WIRE
BUILDING SYSTEMS NETWORK DROP AND COUNT.
GRAY JACK AND WIRE
PUBLIC NETWORK DROP AND COUNT.
ORANGE JACK AND ORANGE OR WHITE WIRE
DEMO DROP TO SOURCE AND COMPONENTS
SURFACE MOUNT BOX
EXISTING TECHNOLOGY POLE - RACEWAY
EXISTING FLOOR BOX
EXISTING JUNCTIION BOX
4 POST ENCLOSED EQUIPMENT CABINET
FB_01
POWER_POLE
SMB-01
DEMO-01
N#
N#
N#
WAP_SMB_01
RISER_DOWN
RISER_UP
ROYAL OAK PUBLIC LIBRARY
NETWORK CABLING UPGRADE
MAIN LEVEL
| Sheets and Views |
| LL-TD-102 |
| Royal Oak Library_Network_Upgrade_LL-T-102.pdf |
| Sheets and Views |
| LL-T-102 |
| Royal Oak Library_Network_Upgrade_ML-TD-101.pdf |
| Sheets and Views |
| ML-TD-101 |
| Royal Oak Library_Network_Upgrade_ML-T-101.pdf |
| Sheets and Views |
| ML-T-101 |
File details come from the government source that posted it. Updated .