Text version
CFGM 2015 Marine Corps Fire & Emergency Services (F&ES) Standard, Version 10 July 2014
Marine Corps F&ES ambulances shall be standardized to the greatest extent. All Marine Corps F&ES ambulances will be ordered with the CFGM option code. Marine Corps F&ES specific requirements shall be furnished in accordance with this standard.
1. The following are standard requirements and shall be included for all Marine Corps F&ES ambulances:
AP – Adjustable pedals B14 – Body length, 14’ CPT – Custom paint color, Sikkens Red FLNA 3042. If an installation requires a different color, it can be requested as an AREQ.
CRS - California steady red light DCAM – Driving camera K05 – Basic medical package K07 – Delete cot, furnish mount only. The installation will specify the type of model and cot to be mounted, along with the desired location of the mounting bracket.
K15C – Reflective chevron on rear K15D – Delete all exterior markings. With K15D, the installation will be responsible for determining, procuring and installing all striping, lettering and decals, except for rear chevrons. Install rear chevrons.
K21 – Severe weather installation package K34F – Front warning lights. See AREQ Section 2 for specific requirements.
K34R – Rear warning lights. See AREQ Section 2 for specific requirements.
PLV - Electric door locks on curbside entrance door and rear entrance doors RKE – Remote keyless entry RBV – Diamond plate aluminum running boards with perforated tread for extra shoe grip SL - 100,000 candle power hand held spot light, hard wired in cab area Emergency Vehicle Seating (EVS Ltd) 1790 or equivalent seating configuration. Two (2) EVS model
1790 folding attendant seats, on swivel bases, on curbside in lieu of standard squad bench configuration.
Swivel bases to lock in forward, 45 degree and 90 degree positions.
2. The following are standard additional requirements (AREQ) for all Marine Corps F&ES ambulances. Specifics pertaining to the type and location of lights can be found on pages 3 through 5.
Include rear zone lower warning light on both sides of the patient compartment. The rear zone lower lighting shall be two (2) Whelen series 700 Super LED flashing warning lights with red lens. Lights shall be located on each side of the patient compartment, centered directly above the rear wheel well.
Include two (2) Whelen series 700 Super LED flashing warning lights with red lens in the front grill in lieu of standard LED warning lights. The rear zone and grill warning lights shall be controlled by the same switch for the light bar warning lights in the cab instrument panel.
Rear warning lights to be upgraded to five (5) 9x7 Super LEDs; two (2) additional 9x7 Super LED warning lights shall be installed on rear, positioned nominally for visibility through the left and right door windows when opened.
Forward facing warning lights shall be seven (7) 9x7 Super LED lights.
Install Whelen (part number 295HFS3) siren with electronic air horn feature, flush mounted center driver console Commercial body, centered rear doors, 50” aisle space, ¾ height compartment D, dogleg in streetside forward compartment for stair chair.
Install fixed hoop step, curbside under patient compartment door, with exterior handle to rear of curbside door opening.
Mount one (1) ABC fire extinguisher on the right hand side of a slide out tray in compartment (A2). Mount one (1) CO2 fire extinguisher against the bulkhead wall behind and to the right of the Captain’s chair.
Delete compartment (A1) exterior door.
No lower windows in curbside and rear patient compartment doors.
Rear windows in patient compartment to be tinted.
Compartment D to be three quarter (3/4) height, with two (2) adjustable shelves.
See drawings on pages 6 through 8 for interior cabinet and seating configurations.
Install California steady red light centered and equally spaced between the cab top and light bar bottom.
Reinforce ambulance module floor with plates to accommodate the Stryker Power Load system.
Patient compartment flooring to be rolled up three (3) inches on face of base wall cabinet and squad bench All Marine Corps F&ES ambulance rear chevrons will alternate between red and either yellow, fluorescent yellow, or fluorescent yellow-green, color will be specified by the installation. The chevron will comply with NFPA 1917, Standard for Automotive Ambulances.
One (1) license plate bracket, sized to accommodate a standard size license plate, shall be furnished and installed by the contractor. The bracket shall be located on the rear of the patient compartment, on the streetside. The bracket will be centered below the tail light cluster and above the bumper cap. A surface mount step light shall illuminate the license plate. Final layout will be determined during the pre-construction/order meeting.
Add Zico tank lift in the streetside forward compartment (F) to accommodate M or H size oxygen cylinder.
The installation will specify the type of oxygen cylinder required.
Mount a Physio-Control cardiac monitor bracket on the extended action surface area. If installation does not use Physio-Control monitors, a specific bracket may be requested.
3. The following are options that are authorized by Marine Corps F&ES and can be requested by the individual installation:
K07F – Mounting system for Ferno iN/X integrated patient transport and loading system K07S – Mounting system for Stryker-POWERLOAD cot fastener system K10 – NCG oxygen outlets in lieu of Ohio style K15A – Ship loose all exterior markings, lettering & belts. With K15A, it will be the responsibility of the installation to determine the configuration and location of striping, lettering, and application of decals. This option then deletes the standard option K15D.
K15B - Delete reflective orange belt – add reflective white belt K27 – Temperature controlled drug compartment K32 – Additional antenna and power leads. The installation will specify the number of antenna and power leads required and the location of each.
K37 – Additional 12 VDC power lead for portable equipment. The installation will specify the number of leads required and the location of each.
K49 – 110/12 volt heat and AC combination unit K51 or K51V– Opticom. The installation will specify the type of Opticom required for their specific area.
It is incumbent upon the installation to determine the type of Opticom that will be compatible with the existing system. K51 is an infrared Opticom and K51V is a visual light Opticom.
Child safety seat built into captain’s chair in patient compartment.
Engel MT-17 or equivalent portable refrigerator with TSL-17 or equivalent slide-lock.
4. The following options are authorized by Marine Corps F&ES, based on the climate and/or specific mission requirements at the installation. Installations desiring these options shall request approval with full justification to Commander, Marine Corps Installations Command (F&ES).
AT – All terrain tire tread AWD – OEM all-wheel drive K31 – Automatic tire chains TT – All terrain tread – rear tires only K19A – Two group 31 batteries in addition to OEM batteries UCT - Undercoating