_PLANS_Hangar_Development_ITB_47-2025.pdf
PDF 17 MB Posted
- Attached to
- Hangar Site Development
- Solicitation number
- ITB-47-2025
- Issued by
- Rutherford County, Tennessee
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LOCATION MAP
NOT TO SCALE
CONSTRUCTION PLANS
MURFREESBORO MUNICIPAL AIRPORT, MBT
HANGAR SITE DEVELOPMENT
FOR
H
AN
G
AR
S
IT
E D
EV
EL
O
PM
EN
T
C O
N
ST
R U
C
TI
O N
P
LA
N S
M U
R
FR
EE
SB
O R
O , T
EN
N
ES
SE
E
FO
R
C0.01
37419-08 SET No. IFB
PROJECT No.
MAY 23 2025
Copyright 2025, Barge Design Solutions, Inc. ALL RIGHTS RESERVED
615 3rd Avenue South // Suite 700 // Nashville, Tennessee 37210
PHONE (615) 254-1500 // FAX (615) 255-6572
U
SE
R :B
C D
AV
EN
PO
R
T
FI
LE
:F
:\3 7\
9\
8\
_C
AD
\A
VI
A\ Sh ee t F ile s\
5_
C
1.
dw g
PL
O
TT
ED
:5 /2
3/
SA
VE
D
:5 /2
3/
AT
MURFREESBORO, TENNESSEE
TENNESSEE DEPARTMENT
OF TRANSPORTATION (TDOT)
BUTCH ELEY, COMMISSIONER
JOHN-PAUL SAALWAECHTER,PE, DIRECTOR OF AERONAUTICS
MURFREESBORO MUNICIPAL AIRPORT
DARREN GORE, CITY MANAGER
STEVE WALDRON, AIRPORT COMMISSION CHAIR
CHAD GEHRKE, AIRPORT DIRECTOR
ISSUED FOR BIDVICINITY MAP
NOT TO SCALE
MURFREESBORO
MUNICIPAL
AIRPORT
LA
KE OBION
DYER
LAUDERDALE
TIPTON
SHELBY
HAYWOOD
CROCKETT
GIBSON
WEAKLEY
HENRY
CARROLL
MADISON
FAYETTE HARDEMAN
CHESTER
MCNAIRY
HENDERSON
BE
NT
O N
DE
CA
TU
R
HARDIN WAYNE
PERRY
HUMPHREYS
HOUSTON
STEWART MONTGOMERY
DICKSON
HICKMAN
LEWIS
LAWRENCE GILES
MAURY
WILLIAMSON
CH
EA
TH
AM
ROBERTSON
LINCOLN
M
AR
SH
AL
L
DAVIDSON
MOORE
FRANKLIN MARION
HAMILTON
BRADLEY POLK
BEDFORD
RUTHERFORD
WILSON
SUMNER
TROUSDALE
MACON
SMITH
DEKALB
CA
NN
ON
WARREN
COFFEE
GRUNDY
VAN
BUREN
WHITE
PUTNAM
JACKSON
CLAY
OVERTON
FENTRESS
PICKETT
SCOTT CAMPBELL
ANDERSON
CUMBERLAND
MORGAN
UNION
CLAIBORNE
GRAINGER
HANCOCK
HAWKINS
SULLIVAN
JOHNSON
WASHIN
GTON
CARTER
UNIC
OIGREENEHAMBLEN
COCKE
JEFFERSON
SEVIER
KNOX
BLOUNT
MONROEMCMINN
ROANE
LOUDON
RHEABLEDSOE
MEIG
S
SEQUATCHIE
INDEX OF CIVIL DRAWINGS
Sheet Number Sheet Title
C0.01 COVER SHEET
C0.02 CONSTRUCTION SAFETY & PHASING PLAN (CSPP)
C0.03 GENERAL NOTES & SUMMARY OF QUANTITIES
C0.21 EXISTING CONDITIONS & DEMOLITION PLAN
C1.01 EROSION CONTROL PLAN - PRE-CONSTRUCTION
C1.02 EROSION CONTROL PLAN - DURING-CONSTRUCTION
C1.03 EROSION CONTROL PLAN - POST-CONSTRUCTION
C1.04 EROSION CONTROL DETAILS
C1.05 EROSION CONTROL DETAILS
C2.01 GRADING & DRAINAGE PLAN
C3.01 UTILITY PLAN
C4.01 STORM DRAIN PROFILES
C4.03 STORM DETAILS
C4.04 STORM DETAILS
C4.05 STORM DETAILS
C4.06 STORM DETAILS
C5.01 WATERLINE PROFILE
C5.02 WATERLINE PROFILE
C5.03 WATERLINE DETAILS
C6.01 SANITARY SEWERPLAN & PROFILE SS-1
C6.02 SANITARY SEWER DETAILS
C6.03 SANITARY SEWER DETAILS
C7.01 FENCING PLAN
5/23/2025
TSA TSA TSA TSA
OFA OFA OFA OFA OFA OFA OFA OFA OFA OFA OFA OFA OFA OFA OFA OFA OFA OFA
OFA OFA OFA OFA OFA OFA OFA OFA OFA OFA OFA OFA OFA OFA OFA OFA OFA OFA
RSA RSA RSA RSA RSA RSA RSA RSA RSA RSA RSA RSA RSA RSA RSA RSA RSA
RSA RSA RSA RSA RSA RSA RSA RSA RSA RSA RSA RSA RSA RSA RSA RSA RSA
TSATSATSA
TSA
TSA
TSATSA
TSA TSA
TSA TSA TSA TSA
TOFA TOFA TOFA TOFA TOFA TOFA TOFA
3741908
H
AN
G
AR
S
IT
E D
EV
EL
O
PM
EN
T
M U
R
FR
EE
SB
O R
O M
U N
IC
IP
AL
A
IR
PO
R T
M U
R
FR
EE
SB
O R
O , T
EN
N
ES
SE
E
FILE NO.
C H
K.
D
R
D
AT
E D
ES
C
R
IP
TI
O
N R
EV
R
EV
IS
IO
N
IN
FO
R
M
AT
IO
N
Copyright 2025, Barge Design Solutions, Inc. ALL RIGHTS RESERVED
3r d
Av en ue S ou th
S ui te
N as hv ille , T en ne ss ee
PH
O N
E (6
) 2
-1
FA
X (6
) 2
-6
U
SE
R :B
C D
AV
EN
PO
R
T
FI
LE
:F
:\3 7\
9\
8\
_C
AD
\A
VI
A\ Sh ee t F ile s\
5_
C
2a .d w g
PL
O
TT
ED
:5 /2
3/
SA
VE
D
:5 /2
3/
AT
T
H E
JE
M
BC
D
-2
3-
IS
SU
ED
F O
R B
ID
C
O N
ST
R
U C
TI
O
N S
AF
ET
Y
PH
AS
IN
G
P
LA
N (C
SP
P)
C0.02
200' 400'100'
SCALE: 1 INCH = 200 FEET
200' 0'
LEGEND
1 1
CL RUNWAY
C
HORIZONTAL
SURFACE (TYP)
PRIMARY SURFACE
PRIMARY SURFACE
PRIMARY SURFACE APPROACH SURFACE
NOTE:
THE PART 77 SECTION VIEW IS CENTERED ON THE RUNWAY CENTERLINE AT THE
CENTERLINE ELEVATION, AND ON THE EXTENDED RUNWAY CENTERLINE AT THE
RUNWAY THRESHOLD ELEVATION TO A POINT 200 FEET BEYOND EACH THRESHOLD.
THE SECTION THEN RISES ALONG THE SLOPE INDICATED ON THE PROFILE VIEW.
RUNWAY END A B C
FAR PART 77 SURFACES
DRAWING NOT TO SCALE
PAVEMENT SAFETY AREA WIDTH*
*ALL DISTANCES ARE CENTERED ABOUT THE
CENTERLINE OF THE AREA LISTED.
SAFETY AREA DIMENSIONS
PROFILE
TRANSITIONAL
SURFACE (TYP)
RUNWAY THRESHOLD
ELEV = B
RUNWAY
CROSS SECTION OF RUNWAY
SCALE: N.T.S.
AIRFIELD BARRICADE DETAIL
C0.03
250'
250' R/W 18-36
600.00'
613.60'
150'
CONSTRUCTION SEQUENCE PLAN
STAGING AND DEBRIS
STORAGE AREA
LOCAL EMERGENCY NUMBERS
EMERGENCY
POLICE DEPARTMENT
FIRE DEPARTMENT
AIRPORT
CONTRACT TIME
LIQUIDATED DAMAGES
(615) 848-3254
(615) 849-2673
(615) 624-8423
BASE BID: HANGAR SITE PREPARATION
SIXTY (60) CALENDAR DAYS
BASE BID: HANGAR SITE PREPARATION:
- MOBILIZATION & PRE-CONSTRUCTION MEASURES.
-FENCING TO BE INSTALLED AS FIRST ITEM OF CONSTRUCTION
TO ENSURE THAT AIRPORT SECURITY IS MAINTAINED AT ALL
TIMES.
- GRADING, STORM DRAIN INSTALLATION, SANITARY SEWER
INSTALLATION, WATERLINE INSTALLATION, GRASSING.
- DEMOBILIZATION.
RW 18-36
TW
A
TW
A
TW
A
TW
A
TW
B
TW
C
TW D
TW ATW A
CONSTRUCTION SAFETY NOTES
1. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE ENGINEER AND THE
OWNER NOT LESS THAN TWO (2) DAYS PRIOR TO ENTERING THE CONSTRUCTION SITE FOR ANY
PURPOSE SO THAT THEY MAY PUBLISH "NOTICES TO AIR MISSIONS" (NOTAM) OF THE
CONSTRUCTION ACTIVITIES.
2. SUFFICIENT SWEEPERS AND CLEAN UP EQUIPMENT SHALL BE PROVIDED IN ORDER THAT ALL
LOOSE MATERIAL, DEBRIS AND MUD CAN BE REMOVED FROM ALL AIRPORT OPERATIONS AREAS
ON A CONTINUOUS BASIS.
3. NO SEPARATE MEASUREMENT OR PAYMENT WILL BE MADE FOR RADIOS, CONSTRUCTION OF AND
MAINTENANCE OF HAUL ROUTES AND CONSTRUCTION ENTRANCE, ETC. AS INCLUDED IN THESE
NOTES. ALL COSTS ASSOCIATED WITH THESE ITEMS MUST BE INCLUDED IN THE CONTRACT BID
PRICES WHICH WOULD MOST LIKELY INCLUDE THEM.
4. THE CONTRACTOR AND PERSONNEL SHALL NOT, AT ANY TIME, BE ON THE RUNWAY OR TAXIWAYS
UNLESS THE AIRPORT MANAGER GIVES PRIOR APPROVAL.
5. THE CONTRACTOR SHALL TAKE EXTREME CAUTION AROUND ALL EXISTING AIRPORT EQUIPMENT.
6. THE CONSTRUCTION ENTRANCE, STAGING AREA, EMPLOYEE PARKING, STOCKPILE AREA, WASTE
AREA AND BORROW AREA SHALL BE COORDINATED WITH THE AIRPORT MANAGER.
7. THE CONTRACTOR SHALL HAVE SOMEONE ON 24-HOUR CALL FOR EMERGENCY MAINTENANCE OF AIRPORT HAZARD LIGHTING AND BARRICADES AND OTHER EMERGENCIES WHICH MAY ARISE AS A
RESULT OF THIS WORK.
8. THE CONTRACTOR'S PERSONNEL AND EQUIPMENT SHALL NOT BE PERMITTED OUTSIDE THE
CONSTRUCTION WORK LIMITS WITHOUT BEING ESCORTED BY THE OWNER APPROVED ESCORT.
9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO REVIEW THE SAFETY PROVISIONS
INCORPORATED IN THE FOLLOWING FEDERAL AVIATION ADMINISTRATION (FAA) DOCUMENTS,
WHICH ARE AVAILABLE FOR REVIEW BY DOWNLOADING THE DOCUMENTS ON-LINE AT
HTTP://WWW.FAA.GOV:
10. THE CONTRACTOR SHALL BE REQUIRED TO MINIMIZE DUST CREATED BY CONSTRUCTION
ACTIVITIES USING WATER OR OTHER DEVICES. ANY COST ASSOCIATED WITH DUST CONTROL
SHALL BE CONSIDERED INCIDENTAL TO THE PROJECT. IN THE EVENT DUST WHICH IS CREATED BY CONSTRUCTION ACTIVITIES BECOMES A HAZARD TO AIRFIELD OPERATIONS AND/OR AIRCRAFT NAVIGATION CONSTRUCTION ACTIVITIES WILL BE SHUT DOWN. THIS SHUTDOWN TIME WILL NOT
BE A BASIS FOR CLAIMS FOR ADDITIONAL CONTRACT TIME OR COMPENSATION.
11. AIRCRAFT OPERATIONS SHALL AT ALL TIMES HAVE PRIORITY OVER ALL VEHICLES, EQUIPMENT
AND PERSONNEL. THE CONTRACTOR SHALL EMPLOY STRICT MEASURES TO PREVENT ANY
CONFLICT BETWEEN HIS PERSONNEL AND AIRCRAFT ON ANY ACTIVE AIRFIELD PAVEMENT. THE
CONTRACTOR SHALL REMAIN CLEAR OF ACTIVE RUNWAYS AND TAXIWAYS.
12. ALL CONTRACTOR VEHICLES, INCLUDING HAULING VEHICLES, THAT ARE AUTHORIZED TO
OPERATE ON THE AIRPORT WITHIN THE DESIGNATED LIMITS OF CONSTRUCTION OR HAUL
ROUTES AS DEFINED HEREIN, SHALL DISPLAY IN FULL VIEW ABOVE THE VEHICLE A 3'X3' OR
LARGER ORANGE AND WHITE CHECKERBOARD FLAG. EACH CHECKERBOARD COLOR BEING 1'
SQUARE. WHEN OPERATING DURING PERIODS OF DARKNESS OR LIMITED VISIBILITY,
CONTRACTOR'S VEHICLE SHALL BE EQUIPPED WITH ROTATING OR FLASHING AMBER LIGHTS.
DURING SUCH PERIODS, HAULING VEHICLES NOT SO EQUIPPED SHALL BE ESCORTED BY A
VEHICLE SO EQUIPPED.
13. CONTRACTOR SHALL CONTROL THE ON-AIRPORT MOVEMENT AND ACTIVITIES OF ITS EMPLOYEES
AND SUBCONTRACTORS.
14. OPEN-FLAME WELDING OR TORCH-CUTTING OPERATIONS ARE PROHIBITED UNLESS ADEQUATE
FIRE AND SAFETY PRECAUTIONS HAVE BEEN APPROVED BY THE OWNER.
15. OPEN TRENCHES, EXCAVATIONS AND STOCKPILED MATERIALS AT THE CONSTRUCTION SITE
SHALL BE PROMINENTLY MARKED WITH ORANGE FLAGS AND LIGHTED WITH FLASHING AMBER
LIGHT UNITS (ACCEPTABLE TO THE OWNER) DURING HOURS OF RESTRICTED VISIBILITY OR
DARKNESS.
16. STOCKPILED MATERIAL SHALL BE CONSTRAINED IN A MANNER TO PREVENT MOVEMENT AS A
RESULT OF AIRCRAFT OR WIND.
17. ANY DAMAGE TO THE EXISTING AIRPORT LIGHTING SYSTEM CAUSED BY CONSTRUCTION
OPERATIONS SHALL BE IMMEDIATELY NOTED TO THE OWNER AND REPAIRED BY THE
CONTRACTOR AT THE CONTRACTOR'S EXPENSE AND TO THE OWNER'S SPECIFICATIONS.
18. DEBRIS, WASTE AND LOOSE MATERIAL CAPABLE OF CAUSING DAMAGE TO AIRCRAFT LANDING GEAR, PROPELLERS AND ROTORS, OR OF BEING INGESTED BY JET ENGINES SHALL NOT BE LEFT
ON ACTIVE AIRCRAFT MOVEMENT AREAS. MATERIAL DROPPED WITHIN THESE AREAS SHALL BE
REMOVED CONTINUOUSLY DURING WORKING HOURS.
ADVISORY CIRCULAR NUMBER 150/5370-10, (LATEST EDITION)
"STANDARDS FOR SPECIFYING CONSTRUCTION OF AIRPORTS"
ADVISORY
CIRCULAR NUMBER 150/5370-2, (LATEST EDITION) "OPERATIONAL
SAFETY ON AIRPORTS DURING CONSTRUCTION"
ADVISORY CIRCULAR NUMBER 150/5210-5, (LATEST EDITION)
"PAINTING, MARKING, AND LIGHTING OF VEHICLES USED ON AN
AIRPORT"
9.1
9.2
9.3
THE CONTRACTOR SHALL FURNISH AND INSTALL TEMPORARY REFLECTORIZED SIGNS TO CLEARLY MARK THE DESIGNATED ACCESS ROUTES TO AFFECTED AREAS OF AIRPORT PROPERTY. CONTRACTOR SHALL CONTROL ACCESS TO THE WORKING AREA BY CONSTRUCTION VEHICLES AS DELINEATED ON THIS PLAN.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR INFORMING ALL PERSONS UNDER THEIR CONTROL THAT UNAUTHORIZED CONSTRUCTION PERSONNEL FOUND IN RESTRICTED AREAS OF THE AIRPORT SHOWN ON THE SAFETY PLAN ARE SUBJECT TO ARREST FOR A PUNISHABLE FEDERAL OFFENSE AND WILL PROMPTLY
AND PERMANENTLY BE REMOVED FROM THE JOB.
THE CONTRACTOR SHALL PROVIDE APPROVED FLAGMAN TO CONTROL ALL CONSTRUCTION TRAFFIC AND
APPROVED GATE GUARD TO CONTROL ALL CONSTRUCTION TRAFFIC ENTERING PROJECT.
CONTRACTOR SHALL CONTROL AND ESCORT ALL CONSTRUCTION TRAFFIC ENTERING AIRPORT TO
PREVENT CONFLICTS WITH AIRCRAFT OPERATIONS.
SPECIAL ACCESS REQUIREMENTS AND OPERATING LIMITATIONS ARE REQUIRED INSIDE THE SECURITY FENCE. THE CONTRACTOR SHALL DELINEATE WORK LIMITS WITHIN THESE AREAS USING STAKES WITH FLAGGING AS NOTED. CONFINE ALL CONTRACTOR'S PERSONNEL, EQUIPMENT AND MATERIALS INSIDE THE
OWNER'S APPROVED WORK LIMITS.
THE CONTRACTOR SHALL PERFORM CONSTRUCTION OPERATIONS AS NECESSARY TO MINIMIZE
ATTRACTION TO BIRDS CAUSED BY PONDED WATER AND GRASS SEED.
THE CONTRACTOR SHALL PROVIDE, INSTALL AND MAINTAIN FLASHING LIGHTS AND BARRICADES ALONG AIRCRAFT APRON EDGES OR WHERE TEMPORARY PAVEMENT CLOSURES OR AIRCRAFT LIMITATIONS ARE REQUIRED. BARRICADES SHALL BE SPACED NO MORE THAN 8 FEET END TO END OR AS NOTED ALONG THE AFFECTED PAVEMENT EDGE OR ACROSS THE PAVEMENT OF A CLOSED TAXIWAY. THE CONTRACTOR SHALL DAILY MAINTAIN THE LIGHTS AND BARRICADES IN AN OPERABLE CONDITION FOR THE DURATION OF THE
PROJECT. THE CONTRACTOR SHALL FURNISH THE OWNER A CONTACT NUMBER FOR 24-HOUR
MAINTENANCE OF LIGHTS AND BARRICADES. THE COST FOR BARRICADES AND LIGHTS SHALL BE
INCIDENTAL TO THE PROJECT.
NO CONSTRUCTION TRAFFIC SHALL ENTER OR CROSS ANY ACTIVE AIRPORT OPERATIONAL AREA EXCEPT
UPON AUTHORIZATION BY THE OWNER.
REFER TO THE GENERAL NOTES FOR REQUIREMENTS PERTAINING TO STORAGE OF CONSTRUCTION
EQUIPMENT AND MATERIALS WHEN NOT IN USE.
THE CONTRACTOR SHALL COMPLY WITH ALL SECURITY REQUIREMENTS SPECIFIED HEREIN. THE
CONTRACTOR SHALL DESIGNATE IN WRITING TO THE OWNER THE NAME OF ITS "CONTRACTOR SECURITY OFFICER". THE CONTRACTOR SECURITY OFFICER SHALL REPRESENT THE CONTRACTOR ON THE SECURITY
REQUIREMENTS OF THE CONTRACT.
THE CONTRACTOR'S SECURITY OFFICER SHALL BE RESPONSIBLE FOR BRIEFING ALL CONTRACTOR
PERSONNEL ON THESE REQUIREMENTS. CONTRACTOR EMPLOYEES SHALL ATTEND THE OWNER'S
SECURITY TRAINING SESSION AND SHALL BE BRIEFED ON THESE REQUIREMENTS PRIOR TO WORKING IN
THE CONSTRUCTION AREAS.
THE CONTRACTOR SHALL ACQUAINT THEIR SUPERVISORS AND EMPLOYEES WITH THE AIRPORT ACTIVITIES AND OPERATIONS THAT ARE INHERENT AT THIS AIRPORT AND SHALL CONDUCT THEIR CONSTRUCTION ACTIVITIES TO CONFORM TO ALL ROUTINE AND EMERGENCY AIR TRAFFIC REQUIREMENTS AND TO THE
GUIDELINES ON SAFETY.
CONTRACTOR TO LOCATE, FIELD VERIFY, AND PROTECT ALL EXISTING UTILITIES BEFORE CONSTRUCTION
WORK BEGINS.
ALL LOCATIONS USED FOR HAUL ROUTES, STAGING AREAS, EMPLOYEE PARKING AND MATERIAL STORAGE
SHALL BE CLEANED UP WHEN ALL CONSTRUCTION IS COMPLETED.
ALL FOREMAN'S SUPERINTENDANT'S VEHICLES SHALL CONTAIN RADIOS CAPABLE OF TRANSMITTING AND
RECEIVING THE UNICOM FREQUENCY OF 123.075. NORMAL RADIO COMMUNICATIONS BETWEEN
CONTRACTOR PERSONNEL WILL NOT BE ALLOWED ON THE UNICOM FREQUENCY OF 123.075 OR ANY
OTHER FAA FREQUENCY. THE CONTRACTOR IS REQUIRED TO MONITOR THE AIRPORT FREQUENCY
WHENEVER THEIR FORCES ARE ON AIRPORT PROPERTY, WHETHER OR NOT THE RUNWAY IS OPEN OR
CLOSED.
THE CONTRACTOR IS ENCOURAGED TO DOCUMENT VIA PICTURES AND/OR VIDEO THE PRE-CONSTRUCTION CONDITION OF ALL PAVEMENTS AND STRUCTURES. ANY DAMAGE NOTICED AFTER THE CONTRACTOR'S MOBILIZATION WILL BE ASSUMED TO BE CAUSED BY THE CONTRACTOR AND SHALL BE FULLY REPAIRED AT
THE CONTRACTOR'S EXPENSE.
NO EQUIPMENT WILL BE ALLOWED WITHIN 75' OF THE PRIMARY RUNWAY 18-36 CENTERLINE. NO EQUIPMENT WILL BE PARKED OR STORED WITHIN 250' OF THE PRIMARY RUNWAY 18-36 CENTERLINE.
NO EQUIPMENT WILL BE ALLOWED WITHIN 39.5' OF TAXIWAY ALPHA'S CENTERLINE. NO EQUIPMENT WILL BE
PARKED OR STORED WITHIN 65.5' OF TAXIWAY ALPHA'S CENTERLINE.
THE EXISTING AIRPORT PAVEMENTS ARE DESIGNED FOR AIRCRAFT TRAFFIC ONLY, AND MAY NOT SUPPORT LOADED TRUCK OR HEAVY EQUIPMENT. ANY DAMAGE RESULTING FROM THE CONTRACTOR'S ACTIONS WILL BE IMMEDIATELY REPAIRED TO FAA STANDARDS AT THE CONTRACTOR'S EXPENSE.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
PROJECT AREA
HAUL ROUTE/STAGING AREA
RUNWAY SAFETY AREA
RUNWAY OBJECT FREE AREAOFA
RSA
LIQUIDATED DAMAGES ARE SET FOR EACH CALENDAR DAY THAT THE PROJECT REMAINS INCOMPLETE AFTER THE SPECIFIED COMPLETION TIME. BASE BID LIQUIDATED DAMAGES WILL BE $2,500 AND MEASURED FOR EACH CALENDAR DAY BEYOND THE
LIMIT OF SIXTY (60) CALENDAR DAYS.
STAGING AND DEBRIS STORAGE AREA
PROJECT AREA
INSTALL AIRFIELD
BARRICADE
(SEE DETAIL BELOW)
HAUL ROUTE TO/FROM
DEJARNETTE LANE
DOUBLE SWING GATE (16'
WIDE DOUBLE SWING
GATE)
NOTES:
1. INTENDED USE FOR THE FOLLOWING:
- MARKING/LIGHTING OF TEMPORARY HAZARDS WITHIN THE AOA
- LONG TERM CLOSURE OF AIRCRAFT ROUTES.
2. INSTALL AT 12' C/C SPACING ALONG FULL WIDTH OF PAVEMENT.
3. BARRICADE SHALL BE EQUIPPED WITH ALTERNATING ORANGE AND WHITE 20"X20" FLAGS.
IN ADDITION TO THE FLAGS, THE BARRICADES SHALL BE EQUIPPED WITH FLASHING RED
CAUTION LIGHT.
4. BARRICADES SHALL BE WATER-FILLED AND MODULAR TO ASSEMBLE/ DISASSEMBLE AND
NEST FOR COMPACT STORAGE.
5. THE CONTRACTOR SHALL PROVIDE, INSTALL AND MAINTAIN ALL BARRICADES DURING
CONSTRUCTION. ALL BARRICADES SHALL REMAIN THE PROPERTY OF MNAA AT THE
COMPLETION OF CONSTRUCTION.
HIGH IMPACT, UV RESISTANT
POLYETHYLENE 10" x 96" x 10"
ORANGE IN COLOR
12" REFLECTIVE ORANGE
AND WHITE STRIPES
@ 45° SLANT.
ALTERNATING ORANGE AND
WHITE FLAGS
SOLAR OR BATTERY POWERED
FLASHER WITH RED LENS (TYP.)8'-0"
12"
(TYP.)
HAUL ROUTE TO/FROM
DEJARNETTE LANE
TAXIWAY OBJECT FREE AREATOFA
TAXIWAY SAFETY AREATSA
3741908
H
AN
G
AR
S
IT
E D
EV
EL
O
PM
EN
T
M U
R
FR
EE
SB
O R
O M
U N
IC
IP
AL
A
IR
PO
R T
M U
R
FR
EE
SB
O R
O , T
EN
N
ES
SE
E
FILE NO.
C H
K.
D
R
D
AT
E D
ES
C
R
IP
TI
O
N R
EV
R
EV
IS
IO
N
IN
FO
R
M
AT
IO
N
Copyright 2025, Barge Design Solutions, Inc. ALL RIGHTS RESERVED
3r d
Av en ue S ou th
S ui te
N as hv ille , T en ne ss ee
PH
O N
E (6
) 2
-1
FA
X (6
) 2
-6
U
SE
R :B
C D
AV
EN
PO
R
T
FI
LE
:F
:\3 7\
9\
8\
_C
AD
\A
VI
A\ Sh ee t F ile s\
5_
C
3.
dw g
PL
O
TT
ED
:5 /2
3/
SA
VE
D
:4 /2
1/
AT
T
H E
JE
M
BC
D
-2
3-
IS
SU
ED
F O
R B
ID
G
EN
ER
AL
N
O
TE
S
SU
M
M
AR
Y O
F Q
U
AN
TI
TI
ES
C0.03
G
EN
ER
AL
N O
TE
S
SU
M M
AR
Y
O F
Q U
AN
TI
TI
ES
C0.03
GENERAL NOTES
1. THE CONTRACTOR MUST SCHEDULE OPERATIONS TO COMPLETE CONSTRUCTION IN THE OVERALL TIME LIMIT SPECIFIED. THE CONTRACTOR IS TO PREPARE A CONSTRUCTION SCHEDULE TO INCLUDE THE PROPOSED SEQUENCE OF CONSTRUCTION AND SUBMIT IT FOR REVIEW AND APPROVAL AT THE
PRE-CONSTRUCTION MEETING.
2. THE CONTRACTOR SHALL COMPLY WITH ALL PERTINENT PROVISIONS OF THE "MANUAL OF ACCIDENT PREVENTION IN CONSTRUCTION" ISSUED BY AGC OF AMERICA, INC. AND THE "SAFETY AND HEALTH
REGULATIONS FOR CONSTRUCTION" ISSUED BY THE UNITED STATES HEALTH DEPARTMENT.
3. THE LOCATIONS OF UTILITIES (INCLUSIVE OF STORM DRAINS) SHOWN WITHIN THESE PLANS ARE APPROXIMATE. EXACT LOCATIONS SHALL BE DETERMINED IN THE FIELD BY THE CONTRACTOR PRIOR TO
CONSTRUCTION. THE CONTRACTOR SHALL CALL THE STATE "ONE CALL" NUMBER OR 811.
4. PROPOSED HAUL ROUTES AND STOCKPILE AREAS SHALL BE APPROVED BY THE ENGINEER AND THE OWNER PRIOR TO THE START OF WORK. ALL CONSTRUCTION TRAFFIC MUST ENTER AND EXIT THE
PROJECT WORK AREA PER DESIGNATED ROUTES.
5. THE CONTRACTOR SHALL REVIEW THE PROJECT CONSTRUCTION SAFETY AND PHASING PLAN AND BE FAMILIAR WITH ALL AIRPORT OPERATIONS SAFETY AREAS. NO EQUIPMENT SHALL BE LEFT ON THE AIRPORT UNLESS IT IS IN THE APPROPRIATE STAGING AREA OR THE CONTRACTOR RECEIVES
PRIOR APPROVAL FROM THE ENGINEER.
6. THE CONTRACTORS EMPLOYEE PERSONAL VEHICLES SHALL BE RESTRICTED TO THE STAGING
AREA, OR OTHER LOCATION APPROVED BY THE ENGINEER AND OWNER. PERSONAL VEHICLES ARE
NOT ALLOWED IN THE AIRPORT OPERATION AREA AT ANY TIME.
7. THE CONTRACTOR IS REQUIRED TO FURNISH ALL STAKING REQUIRED FOR COMPLETION OF THE
PROJECT. HORIZONTAL AND VERTICAL CONTROL ARE TO BE ESTABLISHED BY THE ENGINEER.
8. IN THE EVENT OF ANY DISCREPANCIES AND/OR ERRORS FOUND IN THE DRAWINGS, OR IF PROBLEMS
ARE ENCOUNTERED DURING CONSTRUCTION, THE CONTRACTOR SHALL BE REQUIRED TO NOTIFY
THE ENGINEER IN WRITING BEFORE PROCEEDING WITH THE WORK. IF THE ENGINEER IS NOT
NOTIFIED, THE CONTRACTOR SHALL TAKE RESPONSIBILITY FOR THE COST OF ANY REVISIONS.
9. ELECTRICAL CABLE PROTECTION
9.1. IN ALL CONSTRUCTION AREAS, THE LOCATION OF ALL POWER AND CONTROL CABLES WHICH
ARE TO REMAIN IN SERVICE SHALL BE COORDINATED WITH LOCAL PERSONNEL AND LOCATED
PRIOR TO COMMENCING CONSTRUCTION ACTIVITIES.
9.2. AT ALL LOCATIONS WHERE HAUL ROUTES, ENTRANCE AND EXIT ROADS, AND EQUIPMENT WILL
CROSS ACTIVE UNDERGROUND CABLES, THE CONTRACTOR MUST PROVIDE SUITABLE
PROTECTION OF THE CABLE BY BRIDGING OVER WITH STEEL BOILER PLATE, TIMBER BRIDGING
MATS, OR BOTH, THEN COVERED BY ADEQUATE SAND CLAY RAMPS OF SUFFICIENT DEPTH TO
SPREAD THE LOADS SO DAMAGE TO THE CABLE WILL NOT OCCUR.
9.3. THE CONTRACTOR WILL ALSO BE RESPONSIBLE FOR COORDINATING AND ACCOMPLISHING THE
IMMEDIATE REPAIR AND RESTORATION OF ANY INTERRUPTED SERVICE. IN SOME INSTANCES,
WHEN THE DAMAGED CABLE IS A SPECIALTY CABLE, THE OWNER WILL INSIST UPON MAKING
THE REPAIR. ALL COSTS ASSOCIATED WITH THE REPAIR AND RESTORATION OF SERVICE WILL
BE THE RESPONSIBILITY OF THE CONTRACTOR.
10. SURPLUS MATERIAL NOT RETAINED BY THE AIRPORT AND NOT REQUIRED FOR SITE CONSTRUCTION
SHALL BE DISPOSED OF BY THE CONTRACTOR AT THE CONTRACTORS EXPENSE.
11. THE CONTRACTOR SHALL COORDINATE ALL WORK WITH AIRPORT PERSONNEL.
12. THE CONTRACTOR SHALL COMPLY WITH ALL FEDERAL, STATE, AND LOCAL REGULATIONS AND CODES
13. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING AND PAYING FOR ANY REQUIRED PERMITS AND/OR LICENSES INCLUDING, BUT NOT LIMITED TO, NPDES PERMITS. ALL REPORTING
AND COMPLIANCE WILL BE THE RESPONSIBILITY OF THE CONTRACTOR AND THE CONTRACTORS
EXPENSE.
14. THE CONTRACTOR SHALL BE RESPONSIBLE FOR TAKING ALL NECESSARY MEASURES TO CONTROL
EROSION AND WATER POLLUTION THROUGHOUT THE CONSTRUCTION PERIOD. ALL TEMPORARY
EROSION CONTROL MEASURES SHALL BE IN PLACE BEFORE CONSTRUCTION OPERATIONS BEGIN.
15. THE CONTRACTOR SHALL SCHEDULE INSPECTIONS AND TESTS A MINIMUM OF 48 HOURS IN
ADVANCE, EXCEPT AS OTHERWISE APPROVED BY THE ENGINEER.
16. THE CONTRACTOR SHALL PROVIDE ALL RECORD DRAWINGS, AS-BUILT DRAWINGS, OR
AS-CONSTRUCTED DRAWINGS AT THE COMPLETION OF THE PROJECT AS REQUIRED BY THE
CONTRACT DOCUMENTS.
17. ANY ITEM OR ELEMENT OF WORK THAT DOES NOT HAVE A SPECIFIC PAY ITEM SHALL BE CONSIDERED INCIDENTAL TO MOBILIZATION OR THE CONTRACT ITEM WHICH IT WOULD MOST LIKELY BE INCLUDED
AND NO SEPARATE PAYMENT WILL BE MADE.
18. NO FIELD CHANGES OR DEVIATIONS FROM THE CONSTRUCTION DOCUMENTS SHALL BE MADE
WITHOUT PRIOR APPROVAL FROM THE ENGINEER AND OWNER.
19. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING AND REPAIRING ANY EXISTING
PAVEMENTS AND/OR HAUL ROUTES DAMAGED BY CONSTRUCTION TRAFFIC THROUGHOUT THE
CONSTRUCTION PERIOD AT THE CONTRACTORS EXPENSE. REPAIR METHODS SHALL BE APPROVED
BY THE ENGINEER AND OWNER. THE CONTRACTOR IS ENCOURAGED TO DOCUMENT VIA PICTURES
AND/OR VIDEO THE PRE-CONSTRUCTION CONDITION OF ALL PAVEMENTS AND STRUCTURES.
20. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NECESSARY STABILIZATION OF ALL ACCESS AND
HAUL ROUTES AT THE CONTRACTORS EXPENSE. PRIOR TO FINAL ACCEPTANCE OF THE PROJECT
ALL ACCESS, HAUL ROUTES, STAGING AREAS, BORROW AREAS, AND EMPLOYEE PARKING SHALL BE
REPAIRED TO THEIR ORIGINAL CONDITION AT THE CONTRACTORS EXPENSE.
21. THE CONTRACTOR IS REQUIRED TO HAVE A FULL-TIME SUPERINTENDENT ON THE PROJECT SITE DURING ALL HOURS OF CONSTRUCTION. AN EMERGENCY PHONE NUMBER FOR ISSUES THAT ARISE OUTSIDE OF NORMAL WORKING HOURS WILL BE PROVIDED TO THE ENGINEER AND OWNER BEFORE
CONSTRUCTION OPERATIONS BEGIN.
22. IN THE CASE OF ANY FAILED QUALITY ASSURANCE TESTS CONDUCTED BY THE OWNER, RE-TESTING
SHALL BE AT THE CONTRACTORS EXPENSE.
23. THESE NOTES ARE INTENDED TO SUPPLEMENT PROJECT SPECIFICATIONS AND IN NO WAY
INVALIDATE SPECIFICATIONS PROVIDED IN OTHER BID DOCUMENTS (GENERAL OR SPECIFIC
REQUIREMENTS).
SUMMARY OF QUANTITES
1. COMPLETE SPECIFICATIONS FOR THE WATER LINES, “WATER LINE SPECIFICATIONS AND DRAWINGS”, NOVEMBER 2022 ED., ARE ON FILE AT THE MURFREESBORO WATER RESOURCES DEPARTMENT ENGINEERING ANNEX AND CAN ALSO BE FOUND ONLINE AT HTTPS://WWW.MURFREESBOROTN.GOV/DOCUMENTCENTER/VIEW/26345/2022-FINAL-WATER-SPECIFICATIONS-AND-DETAILS
2. COMPLETE SPECIFICATIONS FOR THE SEWER LINES, “SEWER LINE SPECIFICATIONS AND DRAWINGS”, NOVEMBER 2022 ED., ARE ON FILE AT THE MURFREESBORO WATER RESOURCES DEPARTMENT ENGINEERING ANNEX AND CAN ALSO BE FOUND ONLINE AT HTTPS://WWW.MURFREESBOROTN.GOV/DOCUMENTCENTER/VIEW/26344/2022-FINAL-SEWER-SPECIFICATIONS-AND-DETAILS
3. COMPLETE SPECIFICATIONS FOR THE REPURIFIED WATER LINES, “REPURIFIED WATER SPECIFICATIONS AND DRAWINGS”, NOVEMBER 2022 ED., ARE ON FILE AT THE MURFREESBORO WATER RESOURCES DEPARTMENT ENGINEERING ANNEX AND CAN ALSO BE FOUND ONLINE AT HTTPS://WWW.MURFREESBOROTN.GOV/DOCUMENTCENTER/VIEW/26346/2022-FINAL-REPURIFIED-WATER-SPECIFICATIONS-AND-DETAILS
4. WATER AND SEWER CONSTRUCTION MUST BE IN ACCORDANCE WITH ALL MWRD SPECIFICATIONS AND DRAWINGS.
5. CONCERNING WATER LINE CONSTRUCTION, RESTRAINTS SUCH AS RODS OR KICKERS SHALL BE INSTALLED AT ANY CHANGE IN DIRECTION WHERE FITTINGS ARE REQUIRED, AT ALL DEAD-ENDS, AND AT ANY LOCATION AS DIRECTED BY THE WATER RESOURCES
DEPARTMENT.
6. CONTRACTOR MUST HAVE A STATE OF TENNESSEE LICENSE, MUNICIPAL UTILITY (MU) CLASSIFICATION, TO PERFORM WORK.
7. ALL MAIN LINE WATER TAPS WILL BE MADE BY THE MURFREESBORO WATER RESOURCES DEPARTMENT.
8. UNDER THE CURRENT ADOPTED PLUMBING CODE, THE CITY OF MURFREESBORO REQUIRES THE MINIMUM FLOOR ELEVATION (M.F.E.) TO BE SET AT OR ABOVE THE TOP OF CASTING ELEVATION OF THE NEAREST MANHOLE THAT IS UPSTREAM OF THE SEWER SERVICE CONNECTION. AS AN ALTERNATIVE, THE HOMEOWNER SHALL INSTALL A BACKWATER VALVE PER THE PLUMBING CODE AND EXECUTE AND RECORD A RELEASE OF INDEMNIFICATION AGAINST THE CITY OF MURFREESBORO WITH REGARDS TO THE SANITARY SEWER CONNECTION. THE BUILDER AND/OR HOMEOWNER SHALL BE RESPONSIBLE FOR COMPLIANCE WITH THIS REQUIREMENT.
9. TRENCH CHECK DAMS, AS CALLED OUT IN THE MWRD SPECIFICATIONS, ARE TO BE INSTALLED AT THE DISCRETION OF THE WATER
RESOURCES DEPARTMENT.
10. THE EXISTING SEWER MAINS AND/OR MANHOLES MUST BE TESTED BEFORE AND AFTER CONSTRUCTION. SHOULD THE SEWER NOT BE TESTED PRIOR TO CONSTRUCTION ANY DEFECTS FOUND AFTER CONSTRUCTION WILL BE THE RESPONSIBILITY OF THE CONTRACTOR TO
REPAIR AT HIS OR HER EXPENSE.
11. ALL PROPOSED MANHOLES MUST BE WRAPPED IN A CONSEAL, OR AN APPROVED EQUAL, 12” MINIMUM WATER AND SOIL BARRIER WRAP AT EACH MANHOLE SECTION JOINT AND AT ANY OTHER MANHOLE COMPONENT AS DIRECTED BY MWRD.
12. NO MORE THAN 25 PERCENT OF THE DOLLAR AMOUNT OF THE CONTRACT MAY BE AWARDED TO SUBCONTRACTORS
13. A MAXIMUM OF 2 - 6” (6 IN.) ADJUSTMENT RINGS WILL BE ALLOWED PER ANY EXISTING OR PROPOSED MANHOLES ASSOCIATED WITH THIS INSTALLATION. IF ANY MANHOLE REQUIRES ADJUSTMENT BEYOND THE 2 - 6” ADJUSTMENT RINGS ALLOWED THEN THE CONTRACTOR MUST REMOVE, ADJUST, OR ADD BARREL SECTIONS TO THE MANHOLE TO GET IT TO GRADE AT HIS OR HER OWN EXPENSE.
14. ALL NEWLY CONSTRUCTED SANITARY SEWER MAINS, REHABILITATED SANITARY SEWER LATERALS AND MAINS, EXISTING SANITARY SEWER MAINS THAT INTERSECT UNDER OR OVER A NEWLY CONSTRUCTED OR REMOVED UTILITY, OR ANY SEWER MAIN THAT HAS BEEN PHYSICALLY ALTERED IN ANY WAY MUST BE FULLY TELEVISED VIA AN IN-LINE CLOSED CIRCUIT TELEVISION (CCTV) POST CONSTRUCTION SURVEY FULLY COMPLIANT WITH THE GUIDELINES SET FORTH BY THE NORTH AMERICAN SANITARY SEWER COMPANY'S (NASSCO) PIPELINE ASSESSMENT CERTIFICATION PROGRAM (PACP) AT THE EXPENSE OF THE CONTACTOR.
MWRD STANDARD WATER AND SEWER NOTES
TW
E
TW
F
TW
A
TW A3
EXISTING
APRON
APRON
X X
X X
X
SD SD SD SD48" X 24"
OCTAGONAL RCP
23" X 15"
ERCP
CP 4
END WALL
23" X 15" ELLIPTICAL RCP
INV. 604.88'
23" X 15" ELLIPTICAL RCP
INV. 604.39'
END WALL
48" X 24" OCTAGONAL RCP
INV. 597.37'
CONCRETE
DITCH
CP 3
CP S1
EXISTING 3 PHASE
UNDERGROUND
POWER
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TOFA
TOFA
TOFA
TOFA
TOFA
TOFA
TO
FA
TO
FA
TO
FA
TO
FA
TOFA
TOFA
TOFA
TOFA
END WALL
48" X 24" OCTAGONAL RCP
INV. 595.94'
EXISTING FENCE
TO REMAIN EXISTING FENCE
TO BE REMOVED
N 563351.99 E 1855782.36
N 563854.86 E 1855956.96
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
EXISTING FENCE
TO REMAIN
3741908
H
AN
G
AR
S
IT
E D
EV
EL
O
PM
EN
T
M U
R
FR
EE
SB
O R
O M
U N
IC
IP
AL
A
IR
PO
R T
M U
R
FR
EE
SB
O R
O , T
EN
N
ES
SE
E
FILE NO.
C H
K.
D
R
D
AT
E D
ES
C
R
IP
TI
O
N R
EV
R
EV
IS
IO
N
IN
FO
R
M
AT
IO
N
Copyright 2025, Barge Design Solutions, Inc. ALL RIGHTS RESERVED
3r d
Av en ue S ou th
S ui te
N as hv ille , T en ne ss ee
PH
O N
E (6
) 2
-1
FA
X (6
) 2
-6
U
SE
R :B
C D
AV
EN
PO
R
T
FI
LE
:F
:\3 7\
9\
8\
_C
AD
\A
VI
A\ Sh ee t F ile s\
5_
C
1.
dw g
PL
O
TT
ED
:5 /2
3/
SA
VE
D
:4 /1
6/
AT
T
H E
JE
M
BC
D
-2
3-
IS
SU
ED
F O
R B
ID
EX
IS
TI
N G
C O
N D
IT
IO
N S
D
EM
O
LI
TI
O N
P
LA
N
C0.21
EX
IS
TI
N
G C
O N
D
IT
IO
N
S
D
EM
O
LI
TI
O
N P
LA
N
C0.21
60' 120'
SCALE: 1 INCH = 60 FEET
30'60' 0'
AIRFIELD CONTROL POINTS
LABEL TYPE NORTHING EASTING ELEV
CP 4
CP 3
CP S1
1/2" REBAR WITH CAP
563899.17' 1856416.58'
1856359.37'563016.03'
1/2" REBAR WITH CAP 600.16'
605.58'
564256.33' 1856402.28'1/2" REBAR WITH CAP 596.19'
LEGEND
EXISTING BUILDINGS
3 PHASE UNDERGROUND
POWER LINE
FENCE
EXISTING MAJOR CONTOURS425
EXISTING MINOR CONTOURS
EXISTING PAVEMENT
EXISTING 8"
SANITARY SEWER
EXISTING
SANITARY SEWER
XXXXXXXXXXXX
TO BE DEMOLISHED
REMOVE EXISTING
LIGHT
REMOVE EXISTING
LIGHT
REMOVE EXISTING
LIGHT
REMOVE EXISTING
LIGHT
REMOVE EXISTING
LIGHT
REMOVE EXISTING
LIGHT
REMOVE EXISTING
LIGHT
REMOVE EXISTING
LIGHT
REMOVE EXISTING
LIGHT
REMOVE EXISTING LIGHT
EXISTING FIRE
HYDRANT TO
REMAIN
EXISTING 8" WATER
LINE
EXISTING 6" WATER
LINE
TW
F
TW
A
TW A3
APRON
APRON
X X
X X
X
SD SD SD SD48" X 24"
OCTAGONAL RCP
23" X 15"
ERCP
END WALL
23" X 15" ELLIPTICAL RCP
INV. 604.88'
23" X 15" ELLIPTICAL RCP
INV. 604.39'
END WALL
48" X 24" OCTAGONAL RCP
INV. 597.37'
CONCRETE
DITCH
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TOFA
TOFA
TOFA
TOFA
TOFA
TOFA
TO
FA
TO
FA
TO
FA
TO
FA
TOFA
TOFA
TOFA
TOFA
END WALL
48" X 24" OCTAGONAL RCP
INV. 595.94'
N 563359.93 E 1856201.47
N 563380.88 E 1855865.78
N 563448.00 E 1855756.84
N 563479.92 E 1855526.72
N 563909.20 E 1855527.58
N 564067.41 E 1855968.15
N 564080.94 E 1855534.61
N 563666.56 E 1855523.82
N 563756.35 E 1855504.70
3741908
H
AN
G
AR
S
IT
E D
EV
EL
O
PM
EN
T
M U
R
FR
EE
SB
O R
O M
U N
IC
IP
AL
A
IR
PO
R T
M U
R
FR
EE
SB
O R
O , T
EN
N
ES
SE
E
FILE NO.
C H
K.
D
R
D
AT
E D
ES
C
R
IP
TI
O
N R
EV
R
EV
IS
IO
N
IN
FO
R
M
AT
IO
N
Copyright 2025, Barge Design Solutions, Inc. ALL RIGHTS RESERVED
3r d
Av en ue S ou th
S ui te
N as hv ille , T en ne ss ee
PH
O N
E (6
) 2
-1
FA
X (6
) 2
-6
U
SE
R :B
C D
AV
EN
PO
R
T
FI
LE
:F
:\3 7\
9\
8\
_C
AD
\A
VI
A\ Sh ee t F ile s\
5_
C
1.
dw g
PL
O
TT
ED
:5 /2
3/
SA
VE
D
:4 /2
1/
AT
T
H E
JE
M
BC
D
-2
3-
IS
SU
ED
F O
R B
ID
ER
O
SI
O N
C O
N
TR
O L
P
LA
N
PR
E-
C O
N
ST
R U
C
TI
O N
C1.01
60' 120'
SCALE: 1 INCH = 60 FEET
30'60' 0'
LEGEND
SILT FENCE
INLET PROTECTION
CHECK DAM
EPSC NOTES:
1. THE CONTRACTOR SHALL CONSULT THE LATEST EDITION OF THE TENNESSEE EROSION AND SEDIMENT CONTROL HANDBOOK FOR FACT SHEETS AND DETAILS FOR INFORMATION AND GUIDANCE IN APPLYING TEMPORARY CONSTRUCTION SITE MANAGEMENT PRACTICES (TCPS) TO DISTURBED AREAS INCLUDING:
CONSTRUCTION EXIT
SILT FENCE
INLET PROTECTION
CHECK DAMS
TURF REINFORCED MATTING
RIP RAP
2. ALL DIMENSIONS AND LOCATIONS OF TEMPORARY SOIL EROSION AND WATER POLLUTION CONTROL
DEVICES SHALL BE SUBJECT TO ADJUSTMENT AS DESIGNATED BY THE ENGINEER.
3. WHEN THE TEMPORARY SOIL EROSION AND WATER POLLUTION CONTROL DEVICES ARE NO LONGER REQUIRED FOR THE INTENDED PURPOSE, IN THE OPINION OF THE ENGINEER, THEY SHALL BE REMOVED.
4. CONTRACTOR TO NOTIFY THE AIRPORT AND TDOT THREE DAYS PRIOR TO BEGINNING WORK.
5. ALL SLOPES 3:1 OR GREATER TO BE STABILIZED WITH SOD.
6. ALL GRADED AREAS INCLUDING SLOPES ARE TO BE HYDROSEEDED WITHIN 14 DAYS AFTER GRADING IS
COMPLETE. ONLY ONE APPLICATION OF HYDROSEED WILL BE PAID.
EPSC SEQUENCING NOTES:
1. THE CONTRACTOR SHALL INSTALL THE CONSTRUCTION EXIT BEFORE ANY
OTHER WORK IS COMPLETED.
2. THE CONTRACTOR SHALL INSTALL THE MOST DOWNSTREAM CHECK DAMS ON
EACH CHANNEL.
3. INSTALL PERIMETER SILT FENCE AROUND THE STAGING/STOCKPILE AREA.
4. NO GRADING OPERATIONS SHALL BEGIN UNTIL THE CITY INSPECTOR HAS
APPROVED THE INITIAL INSTALLATION OF EPSC MEASURES.
EXISTING BUILDINGS
EXISTING 3 PHASE
UNDERGROUND POWER LINE
EXISTING FENCE
EXISTING MAJOR CONTOURS425
EXISTING MINOR CONTOURS
EXISTING PAVEMENT
TEMPORARY SEDIMENT BASIN TO PROVIDE 1,370 CY OF WET
STORAGE AND 1,370 CY OF DRY STORAGE.
DRAINAGE AREA TO SEDIMENT BASIN: 19.54 ACRES
TOP OF BANK ELEVATION: ±600.00'
TOP OF DRY STORAGE ELEVATION: 599.90'
TOP OF WET STORAGE ELEVATION: 599.20'
BOTTOM ELEVATION: 598.50'
CULVERT PROTECTION
INSTALL CULVERT
PROTECTION (TYP.)
TW
F
TW
A
TW A3
APRON
APRON
X X
X X
X
SD SD SD SD48" X 24"
OCTAGONAL RCP
23" X 15"
ERCP
END WALL
23" X 15" ELLIPTICAL RCP
INV. 604.88'
23" X 15" ELLIPTICAL RCP
INV. 604.39'
END WALL
48" X 24" OCTAGONAL RCP
INV. 597.37'
CONCRETE
DITCH
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TOFA
TOFA
TOFA
TOFA
TOFA
TOFA
TO
FA
TO
FA
TO
FA
TO
FA
TOFA
TOFA
TOFA
TOFA
END WALL
48" X 24" OCTAGONAL RCP
INV. 595.94'
600600
3741908
H
AN
G
AR
S
IT
E D
EV
EL
O
PM
EN
T
M U
R
FR
EE
SB
O R
O M
U N
IC
IP
AL
A
IR
PO
R T
M U
R
FR
EE
SB
O R
O , T
EN
N
ES
SE
E
FILE NO.
C H
K.
D
R
D
AT
E D
ES
C
R
IP
TI
O
N R
EV
R
EV
IS
IO
N
IN
FO
R
M
AT
IO
N
Copyright 2025, Barge Design Solutions, Inc. ALL RIGHTS RESERVED
3r d
Av en ue S ou th
S ui te
N as hv ille , T en ne ss ee
PH
O N
E (6
) 2
-1
FA
X (6
) 2
-6
U
SE
R :B
C D
AV
EN
PO
R
T
FI
LE
:F
:\3 7\
9\
8\
_C
AD
\A
VI
A\ Sh ee t F ile s\
5_
C
2.
dw g
PL
O
TT
ED
:5 /2
3/
SA
VE
D
:4 /2
1/
AT
T
H E
JE
M
BC
D
-2
3-
IS
SU
ED
F O
R B
ID
ER
O
SI
O N
C O
N
TR
O L
P
LA
N
D U
R
IN
G -C
O N
ST
R
U C
TI
O
N
C1.02
60' 120'
SCALE: 1 INCH = 60 FEET
30'60' 0'
LEGEND
SILT FENCE INSTALLED DURING
PRE-CONSTRUCTION PHASE
INLET PROTECTION INSTALLED
DURING PRE-CONSTRUCTION PHASE
CHECK DAM INSTALLED DURING
PRE-CONSTRUCTION PHASE
EXISTING BUILDINGS
EXISTING 3 PHASE
UNDERGROUND POWER LINE
EXISTING FENCE
EXISTING MAJOR CONTOURS425
EXISTING MINOR CONTOURS
EXISTING PAVEMENT
SILT FENCE
INLET PROTECTION
CHECK DAM
SILT FENCE INSTALLED
DURING PRE-CONSTRUCTION
PHASE (TYP.)
EPSC NOTES:
1. THE CONTRACTOR SHALL CONSULT THE LATEST EDITION OF THE TENNESSEE
EROSION AND SEDIMENT CONTROL HANDBOOK FOR FACT SHEETS AND
DETAILS FOR INFORMATION AND GUIDANCE IN APPLYING TEMPORARY
CONSTRUCTION SITE MANAGEMENT PRACTICES (TCPS) TO DISTURBED AREAS
INCLUDING:
CONSTRUCTION EXIT
SILT FENCE
INLET PROTECTION
CHECK DAMS
TURF REINFORCED MATTING
RIP RAP
2. ALL DIMENSIONS AND LOCATIONS OF TEMPORARY SOIL EROSION AND WATER
POLLUTION CONTROL DEVICES SHALL BE SUBJECT TO ADJUSTMENT AS
DESIGNATED BY THE ENGINEER.
3. WHEN THE TEMPORARY SOIL EROSION AND WATER POLLUTION CONTROL
DEVICES ARE NO LONGER REQUIRED FOR THE INTENDED PURPOSE, IN THE
OPINION OF THE ENGINEER, THEY SHALL BE REMOVED.
4. CONTRACTOR TO NOTIFY THE AIRPORT AND TDOT THREE DAYS PRIOR TO
BEGINNING WORK.
5. ALL SLOPES 3:1 OR GREATER TO BE STABILIZED WITH TURF REINFORCED
MATTING ( NORTH AMERICAN GREEN C350 OR APPROVED EQUIVALENT).
6. ALL GRADED AREAS INCLUDING SLOPES ARE TO BE MULCHED AND SEEDED
WITHIN 14 DAYS AFTER GRADING IS COMPLETE.
EPSC SEQUENCING NOTES:
1. THE CONTRACTOR SHALL MAINTAIN, REPAIR AND/OR
REPLACE EROSION CONTROL MEASURES FROM
PRE-CONSTRUCTION PHASE.
INSTALL INLET
PROTECTION (TYP.)
EXISTING SANITARY
SEWER (TYP.)
TEMPORARY SEDIMENT BASIN TO PROVIDE 1,370 CY OF WET
STORAGE AND 1,370 CY OF DRY STORAGE.
DRAINAGE AREA TO SEDIMENT BASIN: 19.54 ACRES
TOP OF BANK ELEVATION: ±600.00'
TOP OF DRY STORAGE ELEVATION: 599.90'
TOP OF WET STORAGE ELEVATION: 599.20'
BOTTOM ELEVATION: 598.50'
CULVERT PROTECTION
INSTALL CULVERT
PROTECTION (TYP.)
LIMITS OF GRADING
(TYP.)
LIMITS OF GRADING
(TYP.)
10.69 DISTURBED ACRES
INSTALL INLET
PROTECTION (TYP.)
TW
F
TW
A
TW A3
APRON
APRON
X X
X X
X
SD SD SD SD48" X 24"
OCTAGONAL RCP
23" X 15"
ERCP
END WALL
23" X 15" ELLIPTICAL RCP
INV. 604.88'
23" X 15" ELLIPTICAL RCP
INV. 604.39'
END WALL
48" X 24" OCTAGONAL RCP
INV. 597.37'
CONCRETE
DITCH
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TOFA
TOFA
TOFA
TOFA
TOFA
TOFA
TO
FA
TO
FA
TO
FA
TO
FA
TOFA
TOFA
TOFA
TOFA
END WALL
48" X 24" OCTAGONAL RCP
INV. 595.94'
3741908
H
AN
G
AR
S
IT
E D
EV
EL
O
PM
EN
T
M U
R
FR
EE
SB
O R
O M
U N
IC
IP
AL
A
IR
PO
R T
M U
R
FR
EE
SB
O R
O , T
EN
N
ES
SE
E
FILE NO.
C H
K.
D
R
D
AT
E D
ES
C
R
IP
TI
O
N R
EV
R
EV
IS
IO
N
IN
FO
R
M
AT
IO
N
Copyright 2025, Barge Design Solutions, Inc. ALL RIGHTS RESERVED
3r d
Av en ue S ou th
S ui te
N as hv ille , T en ne ss ee
PH
O N
E (6
) 2
-1
FA
X (6
) 2
-6
U
SE
R :B
C D
AV
EN
PO
R
T
FI
LE
:F
:\3 7\
9\
8\
_C
AD
\A
VI
A\ Sh ee t F ile s\
5_
C
3.
dw g
PL
O
TT
ED
:5 /2
3/
SA
VE
D
:4 /2
1/
AT
T
H E
JE
M
BC
D
-2
3-
IS
SU
ED
F O
R B
ID
C1.03
ER
O
SI
O
N C
O N
TR
O
L P
LA
N
PO
ST
-C
O N
ST
R
U C
TI
O
N
60' 120'
SCALE: 1 INCH = 60 FEET
30'60' 0'
PROPOSED MINOR
CONTOURS
EPSC NOTES:
1. THE CONTRACTOR SHALL CONSULT THE LATEST EDITION OF THE TENNESSEE EROSION AND SEDIMENT CONTROL HANDBOOK FOR FACT SHEETS AND DETAILS FOR INFORMATION AND GUIDANCE IN APPLYING TEMPORARY CONSTRUCTION SITE MANAGEMENT PRACTICES (TCPS) TO DISTURBED AREAS INCLUDING:
CONSTRUCTION EXIT
SILT FENCE
INLET PROTECTION
CHECK DAMS
TURF REINFORCED MATTING
RIP RAP
2. ALL DIMENSIONS AND LOCATIONS OF TEMPORARY SOIL EROSION AND WATER POLLUTION CONTROL
DEVICES SHALL BE SUBJECT TO ADJUSTMENT AS DESIGNATED BY THE ENGINEER.
3. WHEN THE TEMPORARY SOIL EROSION AND WATER POLLUTION CONTROL DEVICES ARE NO LONGER REQUIRED FOR THE INTENDED PURPOSE, IN THE OPINION OF THE ENGINEER, THEY SHALL BE REMOVED.
4. CONTRACTOR TO NOTIFY THE AIRPORT AND TDOT THREE DAYS PRIOR TO BEGINNING WORK.
5. ALL SLOPES 3:1 OR GREATER TO BE STABILIZED WITH TURF REINFORCED MATTING ( NORTH AMERICAN
GREEN C350 OR APPROVED EQUIVALENT).
6. ALL GRADED AREAS INCLUDING SLOPES ARE TO BE MULCHED AND SEEDED WITHIN 14 DAYS AFTER
GRADING IS COMPLETE.
EPSC SEQUENCING NOTES:
1. THE CONTRACTOR SHALL REMOVE ALL TEMPORARY EROSION CONTROL MEASURES.
PROPOSED MAJOR
CONTOURS
PROPOSED SOD
PROPOSED HYDRO-SEED
LEGEND
EXISTING BUILDINGS
EXISTING 3 PHASE
UNDERGROUND POWER LINE
EXISTING FENCE
EXISTING MAJOR CONTOURS425
EXISTING MINOR CONTOURS
EXISTING PAVEMENT
PROPOSED SOD
(TYP.)
PROPOSED
HYDRO-SEED
(TYP.)
LIMITS OF GRADING
(TYP.)
LIMITS OF GRADING
(TYP.)
LIMITS OF GRADING
(TYP.)
10.69 DISTURBED ACRES
ER
O
SI
O
N C
O N
TR
O
L D
ET
AI
LS
C1.04
C1.04
SCALE: N.T.S.
EROSION CONTROL - TEMPORARY SILT FENCE
DROP INLET
STAKED STRAW BALES
SURROUNDING DROP INLET
TYPICAL SEDIMENT PROTECTION
UNTIL SURROUNDING AREA
IS STABILIZED
EROSION & SEDIMENT CONTROL NOTES:
C1.04
SCALE: N.T.S.
EROSION CONTROL - INLET PROTECTION
EXISTING
GROUND
MIN. 2.25" (NOMINAL) X 2.25" (NOMINAL)
- (1.75" ACTUAL X 1.75" ACTUAL) (3.06 SQ.
IN.) HARDWOOD POST (OAK OR HICKORY) OR
MIN. 1.25 LB./FT. STEEL POST (STD. "T" OR
"U" SECTION) - LENGTH 58"
FLOW
EXISTING
GROUND
BOTTOM
OF
TRENCH
WOOD POST
(TYP.)
ANCHOR SILT
FENCE
FABRIC 6" DEEP
WITH
4" RUN-OUT
LENGTH
BACKFILL WITH
COMPACTED SOIL
SILT FENCE FABRIC
USE MIN. OF 18
POSTS PER 100
FT. OF LENGTH
ELEVATION VIEWSECTIONAL VIEW
2" M
IN
. MAX 6' POST SPACING
" M
IN
. P
O
ST
4"
6"
8" M
IN
2" M
IN
POSITION POST/FABRIC
ASSEMBLY AT VERTICAL
TO A MAX. 5° FROM
THE VERTICAL (ANGLED
TOWARD FLOW)
SILT FENCE
FABRIC
TOTAL WIDTH
36"
INLET PROTECTION ON
PAVEMENT SURFACES
VARIABLE
1'-6"
2' MAX.
2:1 2:1
FILTERED
WATER
C C
FLOW
FLOW
FL
O
W
MACHINED RIPRAP
(CLASS A-1)
MACHINED RIPRAP
(CLASS A-1)
GEOTEXTILE
FABRIC
1'
1' MIN.
CATCH
BASIN
FLOW
FLO
W
2:1 2:1
GEOTEXTILE FABRIC UNDER ENTIRE
FOOTPRINT OF RIRAP EXTENDED TO
THE EDGE OF THE CATCH BASIN
GEOTEXTILE FABRIC PLACED BETWEEN
MINERAL AGGREGATE LAYER AND RIPRAP
LAYER AND BETWEEN MINERAL AGGREGATE
AND NATURAL GROUND
MINERAL AGGREGATE
(SIZE 57)
MINERAL AGGREGATE
(SIZE 57)
MINERAL AGGREGATE
(SIZE 57)
INLET PROTECTION ON SOIL SURFACES
1. THE EROSION CONTROL DEVICES SHALL BE THE FIRST ITEM OF CONSTRUCTION AND REMAIN FUNCTIONAL. THEY WILL REQUIRE PERIODIC MAINTENANCE AS
PART OF THE CONTRACT.
2. THE CONTRACTOR SHALL PROVIDE EROSION CONTROL WHERE REQUIRED. THE CONTRACTOR SHALL PROVIDE EROSION CONTROL DEVICES AS REQUIRED BY
LOCAL, STATE AND FEDERAL REGULATIONS AT NO ADDITIONAL COST.
3. ALL STORM SEWER DEVICES SHALL BE COMPLETELY SURROUNDED WITH A SEDIMENT BARRIER CONSISTING OF AS INLET PROTECTION DEVICE TO PREVENT SEDIMENT FROM ENTERING THE STORM SEWER SYSTEM. THE DEVICES SHALL BE CONTINUOUSLY MAINTAINED AND SECONDARY SYSTEMS INSTALLED AS NEEDED. THESE DEVICES SHALL REMAIN IN PLACE UNTIL THE FINAL SURFACE HAS BEEN ESTABLISHED.
4. ALL EROSION CONTROL DEVICES SHALL BE REMOVED AT THE END OF THE PROJECT.
5. CONSTRUCTION ENTRANCE SHALL BE USED IN ACCORDANCE WITH SPECIFICATIONS.
6. THE ENGINEER MAY REQUIRE ADDITIONAL EROSION CONTROL AS THE PROJECT PROGRESSES.
7. CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION AND MAINTENANCE OF NOTED EROSION CONTROL MEASURES.
8. OUTFALL POINTS SHALL BE INSPECTED TO ASCERTAIN WHETHER EROSION AND SEDIMENT CONTROL MEASURES ARE EFFECTIVE IN PREVENTING IMPACTS TO SURROUNDING WATERS. LOCATIONS WHERE VEHICLES ENTER AND EXIT THE SITE SHALL BE INSPECTED FOR EVIDENCE OF OFF-SITE ROADWAY SEDIMENT
TRACKING.
9. THE CONTRACTOR SHALL TAKE APPROPRIATE STEPS TO ENSURE THAT PETROLEUM PRODUCTS OR OTHER CHEMICAL POLLUTANTS ARE PREVENTED FROM ENTERING WATERS OF THE STATE/U.S. ALL EQUIPMENT REFUELING, SERVICING, AND STAGING AREAS SHALL COMPLY WITH ALL LOCAL, STATE, AND FEDERAL LAWS, RULES, REGULATIONS, AND ORDINANCES; INCLUDING THOSE OF THE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA). APPROPRIATE CONTAINMENT MEASURES FOR THESE AREAS SHALL BE UTILIZED. ALL SPILLS MUST BE REPORTED TO THE APPROPRIATE AGENCY, AND MEASURES SHALL BE TAKEN IMMEDIATELY TO PREVENT POLLUTION OF WATERS OF THE STATE/U.S. INCLUDING GROUNDWATER, SHOULD A SPILL OCCUR.
10. ANY DISAGREEMENT BETWEEN THE PROJECT PLANS, THE PROJECT AS CONSTRUCTED AND THE PERMIT OR PERMITS ISSUED FOR THE PROJECT, SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER. THE APPROPRIATE AGENCY SHALL DECIDE WHICH HAS PRECEDENCE AND WHETHER PERMIT OR PLANS
REVISIONS ARE NEEDED. IN GENERAL, THE MOST STRINGENT CONDITIONS WILL PREVAIL.
11. THE PLACEMENT AND LOCATION OF TEMPORARY BMPS SHALL BE MODIFIED THROUGHOUT THE CONSTRUCTION PROCESS. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO MAINTAIN A FUNCTIONING EROSION AND SEDIMENT CONTROL PLAN.
12. PRE-CONSTRUCTION VEGETATION SHALL NOT BE DISTURBED MORE THAN 10 DAYS PRIOR TO ANY EXCAVATING ACTIVITIES.
13.TEMPORARY SOIL STABILIZATION MUST BE APPLIED TO ALL DENOTED AREAS WITHIN 7 DAYS OF COMPLETION OF GRADING ACTIVITIES OR TO OTHER DENOTED
AREAS WHICH ARE TO REMAIN DORMANT FOR LONGER THAN 14 DAYS.
14. THE PROPOSED CONSTRUCTION ENTRANCES SHALL BE STABILIZED. NO ACCESS IS TO BE PROVIDED DIRECTLY TO THE PUBLIC RIGHT-OF-WAY WITHOUT AN APPROVED CONSTRUCTION ENTRANCE. PERIODIC TOP DRESSING OF THE CONSTRUCTION ENTRANCE WITH 2-3" STONE MAY BE REQUIRED TO PREVENT THE
ACCUMULATION OF DUST AND MUD ON THE PUBLIC ROADS.
15. ON AND OFF-SITE DUST AND MUD TO BE CONTROLLED AT ALL TIMES THROUGHOUT THE LIFE OF THE CONSTRUCTION PROJECT. THIS MAY REQUIRE PERIODIC ON-SITE WATERING OR OTHER METHODS FOR DUST CONTROL AND PERIODIC WASHING OF THE PUBLIC STREETS AS MAY BE NECESSARY. DUST AND MUD ARE NOT ALLOWED BEYOND THE LIMITS OF CONSTRUCTION. EXISTING BUILDINGS AND VEHICLE STORAGE AREA TO BE PROTECTED FROM DUST AT ALL TIMES.
16. SILT BARRIERS MAY BE REQUIRED TO BE PLACED AT THE TOP OF SLOPES UNTIL ESTABLISHMENT OF PERMANENT VEGETATION ON THE SLOPES AND AROUND
THE PROPOSED PAVEMENT AREAS.
17. ANY STOCKPILED SOIL OR FILL MATERIAL SHALL BE LOCATED AND TREATED IN A MANNER TO PREVENT SILT FROM ENTERING STREAMS. NO EXCAVATED MATERIAL SHALL BE DISCHARGED INTO DITCHES. THE CONTRACTOR SHALL DISPOSE/STOCKPILE ALL EXCAVATED MATERIAL IN A LOCATION, APPROVED BY THE
ENGINEER, ABOVE THE NORMAL HIGH WATER ELEVATION.
18. SEDIMENT CONTROL DEVICES ARE TO BE PERIODICALLY CLEANED OF SILT WHEN ACCUMULATION REDUCES THE DESIGN CAPACITY OF THE DEVICE BY 50%.
THE DEVICES SHALL BE CHECKED WEEKLY AND WITHIN 24 HOURS AFTER EVERY MEASURABLE RAINFALL. IN THE EVENT OF CONTINUOUS RAINFALL, EROSION CONTROLS SHALL BE CHECKED DAILY. ANY FAILURE OF A CONTROL DEVICE SHALL BE CORRECTED WITHIN SEVEN DAYS. UPON CONCLUSION OF THE INSPECTIONS, EROSION AND SEDIMENT CONTROL MEASURES FOUND TO BE INEFFECTIVE ACCORDING TO OWNER TURBIDITY LEVELS SHALL BE REPAIRED, REPLACED, OR MODIFIED BEFORE THE NEXT RAIN EVENT, IF POSSIBLE, BUT IN NO CASE MORE THAN SEVEN DAYS AFTER THE CONDITION IS IDENTIFIED. THE CONTRACTOR WILL KEEP A LOG OF ALL INSPECTIONS AND REPAIR EFFORTS DURING THE CONSTRUCTION PERIOD.
19. THE CONTRACTOR SHALL PROVIDE TEMPORARY EROSION AND WATER CONTROL MEASURES (BMP'S) AS DIRECTED BY THE ENGINEER. THESE TEMPORARY MEASURES SHALL BE COORDINATED WITH THE PERMANENT EROSION CONTROL FEATURES TO ASSURE ECONOMICAL, EFFECTIVE, AND CONTINUOUS EROSION
CONTROL THROUGHOUT THE PROJECT.
20. REMOVAL OF STANDING, MUDDY WATER FROM THE SITE SHALL BE ACCOMPLISHED WITH A PUMP/FILTER BAG COMBINATION OR SAID WATER WILL BE DIVERTED
INTO EXISTING SEDIMENT CONTROL DEVICES VIA A PUMP.
21. EXPOSED LITTER, DEBRIS, CHEMICALS, ETC., SHALL BE PROPERLY STORED AND DISPOSED OF PRIOR TO ANTICIPATED STORM EVENTS.
3741908
H
AN
G
AR
S
IT
E D
EV
EL
O
PM
EN
T
M U
R
FR
EE
SB
O R
O M
U N
IC
IP
AL
A
IR
PO
R T
M U
R
FR
EE
SB
O R
O , T
EN
N
ES
SE
E
FILE NO.
C H
K.
D
R
D
AT
E D
ES
C
R
IP
TI
O
N R
EV
R
EV
IS
IO
N
IN
FO
R
M
AT
IO
N
Copyright 2025, Barge Design Solutions, Inc. ALL RIGHTS RESERVED
3r d
Av en ue S ou th
S ui te
N as hv ille , T en ne ss ee
PH
O N
E (6
) 2
-1
FA
X (6
) 2
-6
U
SE
R :B
C D
AV
EN
PO
R
T
FI
LE
:F
:\3 7\
9\
8\
_C
AD
\A
VI
A\ Sh ee t F ile s\
5_
C
4.
dw g
PL
O
TT
ED
:5 /2
3/
SA
VE
D
:8 /6
/2
AT
T
H E
JE
M
BC
D
-2
3-
IS
SU
ED
F O
R B
ID
AN
G
AR
S
IT
E D
EV
EL
O
PM
EN
T
M U
R
FR
EE
SB
O R
O M
U N
IC
IP
AL
A
IR
PO
R T
M U
R
FR
EE
SB
O R
O , T
EN
N
ES
SE
E
FILE NO.
C H
K.
D
R
D
AT
E D
ES
C
R
IP
TI
O
N R
EV
R
EV
IS
IO
N
IN
FO
R
M
AT
IO
N
Copyright 2025, Barge Design Solutions, Inc. ALL RIGHTS RESERVED
3r d
Av en ue S ou th
S ui te
N as hv ille , T en ne ss ee
PH
O N
E (6
) 2
-1
FA
X (6
) 2
-6
U
SE
R :B
C D
AV
EN
PO
R
T
FI
LE
:F
:\3 7\
9\
8\
_C
AD
\A
VI
A\ Sh ee t F ile s\
5_
C
4.
dw g
PL
O
TT
ED
:5 /2
3/
SA
VE
D
:8 /6
/2
AT
T
H E
JE
M
BC
D
-2
3-
IS
SU
ED
F O
R B
ID
C1.05
SCALE: N.T.S.
EROSION CONTROL - CULVERT PROTECTION
ER
O
SI
O
N C
O N
TR
O
L D
ET
AI
LS
C1.05
TW
F
TW
A
TW A3
APRON
APRON
600600
X X
X X
X
SD SD SD SD48" X 24"
OCTAGONAL RCP
23" X 15"
ERCP
END WALL
23" X 15" ELLIPTICAL RCP
INV. 604.88'
23" X 15" ELLIPTICAL RCP
INV. 604.39'
END WALL
48" X 24" OCTAGONAL RCP
INV. 597.37'
CONCRETE
DITCH
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TOFA
TOFA
TOFA
TOFA
TOFA
TOFA
TO
FA
TO
FA
TO
FA
TO
FA
TOFA
TOFA
TOFA
TOFA
END WALL
48" X 24" OCTAGONAL RCP
INV. 595.94'
CB - D211
STA:20+00.00
RIM:604.00
INV OUT:601.28 15" RCP
JB - D20
STA:13+61.34
RIM:603.98
INV IN:600.00 30"x19" RCP
CB - D22
STA:10+00.00
RIM:603.25
INV OUT:601.00 15" RCP
CB - D21
STA:12+41.30
RIM:603.25
INV IN:600.40 15" RCP
INV IN:600.50 15" RCP
INV OUT:600.30 30"x19" RCP
1.
' o f 1 5"
R C
P
.2
5%
0.
' o f 3 0" x1 9"
R C
P
.2
5%
156.60' of 1 5" R
CP @
0.50%
HW - D151
STA:40+00.00
RIM:605.22
INV OUT:602.01 30"x19" RCP
JB - D14
STA:32+50.00
RIM:604.92
INV IN:600.60 30"x19" RCP INV IN:600.50 38"x24" RCP
INV OUT:600.34 45"x29" RCP
CB - D16
STA:30+00.00
RIM:604.50
INV OUT:601.27 30"x19" RCPCB - D13
STA:33+65.00
RIM:604.50
INV IN:600.00 45"x29" RCP INV OUT:599.88 45"x29" RCP
CB - D11
STA:36+14.30
RIM:604.50
INV IN:598.93 53"x34" RCP INV OUT:598.73 53"x34" RCP
CB - D141
STA:50+00.00
RIM:604.28
INV OUT:600.99 30"x19" RCP
CB - D15
STA:31+73.00
RIM:604.23
INV IN:600.75 30"x19" RCP INV IN:600.85 30"x19" RCP INV OUT:600.73 38"x24" RCP
CB - D12
STA:34+75.92
RIM:603.90
INV IN:599.55 45"x29" RCP INV OUT:599.35 53"x34" RCP
HW - D10
STA:36+75.72
RIM:603.76
INV IN:598.50 53"x34" RCP
173.00' of 30"x19" RCP @ 0.30%
77.00' of 38"x24" RCP @ 0.30%
61.43' of 53"x34" RCP @ 0.38% 138.37' of 53"x3
4" R
CP @
0.30%
9.
' o f 3 0" x1 9"
R C
P
.3
1%
115.00' of 45"x29" RCP @ 0.30%
110.92' of 45"x29" RCP @ 0.30%
71.00' of 30"x19" RCP @ 0.55%
+0
+0
+0
+0
+6
20+00
21+00
21+57
+7
30+00 31+0032+00
+0
34+00
35+00
36+00
+0
+0
+0
+0
+8
050+7150+00
3741908
H
AN
G
AR
S
IT
E D
EV
EL
O
PM
EN
T
M U
R
FR
EE
SB
O R
O M
U N
IC
IP
AL
A
IR
PO
R T
M U
R
FR
EE
SB
O R
O , T
EN
N
ES
SE
E
FILE NO.
C H
K.
D
R
D
AT
E D
ES
C
R
IP
TI
O
N R
EV
R
EV
IS
IO
N
IN
FO
R
M
AT
IO
N
Copyright 2025, Barge Design Solutions, Inc. ALL RIGHTS RESERVED
3r d
Av en ue S ou th
S ui te
N as hv ille , T en ne ss ee
PH
O N
E (6
) 2
-1
FA
X (6
) 2
-6
U
SE
R :B
C D
AV
EN
PO
R
T
FI
LE
:F
:\3 7\
9\
8\
_C
AD
\A
VI
A\ Sh ee t F ile s\
5_
C
1.
dw g
PL
O
TT
ED
:5 /2
3/
SA
VE
D
:5 /2
3/
AT
T
H E
JE
M
BC
D
-2
3-
IS
SU
ED
F O
R B
ID
G
R
AD
IN
G
D
R
AI
N
AG
E
PL
AN
C2.01
60' 120'
SCALE: 1 INCH = 60 FEET
30'60' 0'
STORM LINE SD 1
(SEE SHEET FOR C4.01
FOR PROFILES)
STORM LINE SD 4
(SEE SHEET FOR C4.01
FOR PROFILES)
STORM LINE SD 5
(SEE SHEET FOR C4.01
FOR PROFILES)
LEGEND
EXISTING BUILDINGS
EXISITNG 3 PHASE
UNDERGROUND POWER LINE
EXISTING FENCE
EXISTING MAJOR CONTOURS425
EXISTING MINOR CONTOURS
EXISTING PAVEMENT
PROPOSED MAJOR CONTOURS425
PROPOSED MINOR CONTOURS
PROPOSED STORM DRAIN PIPE
PROPOSED STORM MANHOLE
PROPOSED STORM HEADWALL
PROTECT EXISTING
SANITARY LINE
FUTURE HANGAR
FUTURE PROJECTS
NOTES:
1. FOR THE PURPOSE OF PIPE SIZING, RUNOFF COEFFICIENT C=0.95 WAS USED IN
CALCULATING FLOW Q TO INSURE ADEQUATE PIPE CAPACITY FOR FUTURE DEVELOPMENT.
2. FOR THE PURPOSE OF RUNOFF QUALITY & QUANTITY FACILITIES REQUIREMENTS, RUNOFF
COEFFICIENT C=0.44 WAS USED FOR BOTH PRE-CONSTRUCTION AND
POST-CONSTRUCTION CALCULATIONS.
3. SINCE NO SIGNIFICANT CHANGE TO RUNOFF CHARACTERISTICS (GROUNDCOVER, GRADES,
ETC.), WATER QUALITY & QUANTITY MANAGEMENT FACILITIES ARE NOT INCLUDED IN THIS
PROJECT. REQUIRED WATER QUALITY & QUANTITY MANAGEMENT FACILITIES FOR FUTURE
DEVELOPMENT WILL BE INCLUDED IN FUTURE DEVELOPMENT PLANS.
4. WATER QUALITY/WATER QUANTITY MANAGEMENT FACILITIES WILL BE REQUIRED FOR
FUTURE DEVELOPMENT BEYOND IMPROVEMENTS REPRESENTED IN THESE PLANS.
5. SEE SHEET C1.03 FOR POST-CONSTRUCTION EROSION AND SEDIMENT CONTROL
MEASURES.
STORM LINE SD 2
(SEE SHEET FOR C4.01
FOR PROFILES)
STORM LINE SD 1
(SEE SHEET FOR C4.01
FOR PROFILES)
STORM LINE SD 3
(SEE SHEET FOR C4.01
FOR PROFILES)
STORM LINE SD 3
(SEE SHEET FOR C4.01
FOR PROFILES)
X X
X X
X
EXISTING 3 PHASE
UNDERGROUND
POWER
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TSA
TOFA
TOFA
TOFA
TOFA
TOFA
TOFA
TO
FA
TO
FA
TO
FA
TO
FA
TOFA
TOFA
TOFA
TOFA
TW
E
TW
F
TW
A
TW A3
APRON
APRON
MH082J0030
STA:0+00.00
RIM:604.73
INV IN:596.33 8" SDR 26 PVC
EX INV OUT:596.23 SDR 26 PVC FIELD VERIFY
MH082J003A
STA:2+04.82
RIM:603.21
INV IN:597.25 8" SDR 26 PVC
INV OUT:597.15 8" SDR 26 PVC
20'
30'
204.82' of 8" PVC @ 0.40%
MH082J003B
STA:3+00.00
RIM:602.89
INV OUT:597.63 8" SDR 26 PVC
FUTURE 6" SERVICE LINE INVERT 597.70
20'
95.18' of 8" PVC @ -0.40%
3741908
H
AN
G
AR
S
IT
E D
EV
EL
O
PM
EN
T
M U
R
FR
EE
SB
O R
O M
U N
IC
IP
AL
A
IR
PO
R T
M U
R
FR
EE
SB
O R
O , T
EN
N
ES
SE
E
FILE NO.
C H
K.
D
R
D
AT
E D
ES
C
R
IP
TI
O
N R
EV
R
EV
IS
IO
N
IN
FO
R
M
AT
IO
N
Copyright 2025, Barge Design Solutions, Inc. ALL RIGHTS RESERVED
3r d
Av en ue S ou th
S ui te
N as hv ille , T en ne ss ee
PH
O N
E (6
) 2
-1
FA
X (6
) 2
-6
U
SE
R :B
C D
AV
EN
PO
R
T
FI
LE
:F
:\3 7\
9\
8\
_C
AD
\A
VI
A\ Sh ee t F ile s\
5_
C
1.
dw g
PL
O
TT
ED
:5 /2
3/
SA
VE
D
:5 /2
3/
AT
T
H E
JE
M
BC
D
-2
3-
IS
SU
ED
F O
R B
ID
U
TI
LI
TY
P
LA
N
C3.01
60' 120'
SCALE: 1 INCH = 60 FEET
30'60' 0'
PROPOSED
10" WATER
LINE
SANITARY SEWER SS-1
(SEE SHEET C6.01 FOR
PROFILE AND STORM
DRAIN LOCATIONS)
EXISTING
SANITARY
SEWER LINE
EXISTING XX"
SANITARY
SEWER LINE
TIE INTO EXISTING
SANITARY SEWER
MANHOLE
LEGEND
EXISTING BUILDINGS
EXISITNG 3 PHASE
UNDERGROUND POWER LINE
EXISTING FENCE
PROPOSED SANITARY
SEWER LINE
EXISTING PAVEMENT
PROPOSED WATER LINE
EXISTING SANITARY
SEWER MANHOLE
W
EXISTING SANITARY
SEWER LINE
PROPOSED SANITARY
SEWER MANHOLES
FUTURE HANGAR
FUTURE PROJECTS
PROPOSED 20'
WATER LINE
EASEMENT
PROPOSED 20'
POWER LINE
EASEMENT
PROPOSED 30'
SANITARY SEWER
EASEMENT
WATER LINE
(SEE SHEET C5.01 FOR
PROFILE, STORM DRAIN
LOCATIONS, AND PIPE
FITTINGS)
CONNECT TO EXISTING
8" WATER LINE
(SEE SHEET C5.02 FOR
PROFILE, STORM DRAIN
LOCATIONS, AND PIPE
FITTINGS)
CONNECT TO EXISTING 6"
WATERLINE (SEE SHEET
C5.01 FOR PROFILE,
STORM DRAIN LOCATIONS,
AND PIPE FITTINGS)
FUTURE SERVICE
LATERAL, NOT
PART OF THIS
PROJECT
FUTURE SERVICE
LATERAL, NOT
PART OF THIS
PROJECT
FUTURE SERVICE
LATERAL, NOT
PART OF THIS
PROJECT
FUTURE SERVICE
LATERAL, NOT
PART OF THIS
PROJECT
REMOVE APPROXIMATELY 20' OF EXISTING
FENCE TO ALLOW FOR WATERLINE
INSTALLATION. RE-INSTALL FENCE UPON
COMPLETION OF WATERLINE INSTALLATION.
IF EXISTING 3-PHASE POWER IS EXPOSED
DURING GRADING OPERATIONS, CONTACT
MIDDLE TENNESSEE ELECTRIC TO
SCHEDULE AN INSPECTION.
SD 1
9+00 10+00 11+00 12+00 13+00 14+00 15+00
2.
3.
3.
4.
3.
4.
4.
4.
4.
4.
4.
3.
4.
3.
3.
3.
SD 2
19+00 20+00 21+00 22+00 23+00
CB - D22
STA:10+00.00
RIM:603.25
INV OUT:601.00 15" RCP
241.30' of 15" RCP @ 0.25%
CB - D21
STA:12+41.30
RIM:603.25
INV IN:600.40 15" RCP
INV IN:600.50 15" RCP
INV OUT:600.30 30"x19" RCP
120.03' of 30"x19" RCP @ 0.25%
JB - D20
STA:13+61.34
RIM:603.98
INV IN:600.00 30"x19" RCP
5.
4.
5.
4.
5.
4.
4.
3.
CB - D211
STA:20+00.00
RIM:604.00
INV OUT:601.28 15" RCP
156.60' of 15" RCP @ 0.50%
CB - D21
STA:12+41.30
RIM:603.25
INV IN:600.40 15" RCP
INV IN:600.50 15" RCP
INV OUT:600.30 30"x19" RCP
SD 3
29+00 30+00 31+00 32+00 33+00 34+00 35+00 36+00 37+00 38+00
4.
4.
5.
5.
5.
5.
3.
4.
3.
4.
3.
4.
3.
4.
3.
4.
3.
4.
2.
4.
2.
4.
3.
4.
3.
4.
1.
4.
SD 4
39+00 40+00 41+00 42+00 43+00 44+00 45+00
SD 5
49+00 50+00 51+00 52+00
CB - D16
STA:30+00.00
RIM:604.50
INV OUT:601.27 30"x19" RCP
173.00' of 30"x19" RCP @ 0.30%
CB - D15
STA:31+73.00
RIM:604.23
INV IN:600.75 30"x19" RCP INV IN:600.85 30"x19" RCP
INV OUT:600.73 38"x24" RCP
77.00' of 38"x24" RCP @ 0.30%
115.00' of 45"x29" RCP @ 0.30%
CB - D13
STA:33+65.00
RIM:604.50
INV IN:600.00 45"x29" RCP
INV OUT:599.88 45"x29" RCP
110.92' of 45"x29" RCP @ 0.30%
CB - D12
STA:34+75.92
RIM:603.90
INV IN:599.55 45"x29" RCP
INV OUT:599.35 53"x34" RCP
138.37' of 53"x34" RCP @ 0.30%
CB - D11
STA:36+14.30
RIM:604.50
INV IN:598.93 53"x34" RCP
INV OUT:598.73 53"x34" RCP
61.43' of 53"x34" RCP @ 0.38%
HW - D10
STA:36+75.72
RIM:603.76
INV IN:598.50 53"x34" RCP
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
3.
3.
3.
3.
3.
3.
HW - D151
STA:40+00.00
RIM:605.22
INV OUT:602.01 30"x19" RCP
379.84' of 30"x19" RCP @ 0.31%
CB - D15
STA:31+73.00
RIM:604.23
INV IN:600.75 30"x19" RCP INV IN:600.85 30"x19" RCP INV OUT:600.73 38"x24" RCP
3.
3.
3.
3.
CB - D141
STA:50+00.00
RIM:604.28
INV OUT:600.99 30"x19" RCP
71.00' of 30"x19" RCP @ 0.55%
JB - D14
STA:32+50.00
This is the start of the file's text. The full file is on GovTribe.