Plans.pdf
PDF 5 MB Posted
- Attached to
- 26-03 Ham892326B (Hamilton)
- Solicitation number
- 26-03 Ham892326B (Hamilton)
- Issued by
- Hancock County, Iowa
About this file
This bid plans document prepared by Bolton & Menk, Inc. for Hamilton County, Iowa describes the construction specifications for a Nutrient Reduction Wetland project (IDALS No. HAM892326B). The project involves the design and construction of a constructed wetland system utilizing Conservation Practice Standard 656, classified as NRCS Job Class IV, to manage stormwater and reduce nutrient loading across a 605-acre watershed. Key construction elements include excavation of approximately 19,671 cubic yards, installation of 1,344 linear feet of 12-inch diameter reinforced concrete pipe, 932 linear feet of 15-inch diameter reinforced concrete pipe, and 369 linear feet of 18-inch diameter reinforced concrete pipe, along with 1,579 linear feet of 15-inch smooth-lined corrugated polyethylene drainage tubing. The project requires construction of modified SW-513 inlet and outlet structures, a SW-401 concrete manhole structure, installation of riprap totaling 33.3 tons, and completion of related site improvements. The bid plans include detailed construction details, profiles, and specifications referencing Iowa Department of Agriculture and Land Stewardship standards, Natural Resources Conservation Service specifications, and Iowa Department of Transportation standards.
The project encompasses a total easement area of 26.5 acres with a 20-acre buffer zone, establishing a wetland pool of 6.5 acres at normal water level (elevation 1170.50 feet) with a pool storage volume of 3.1 acre-feet. Design criteria include a maximum pool depth of 1.0 foot with no deep water area exceeding three feet, and the structure is designed to manage 25-year storm events with a peak inflow of 621 cubic feet per second and 100-year storm events with peak inflows of 864 cubic feet per second. The project plans were designed by Brandon C. Short, PE (Iowa License No. 29449), with drawings dated January 22, 2026, and prepared by Bolton & Menk, Inc. of Ames, Iowa. Bid documents indicate that the contractor is responsible for contacting Iowa One Call (811) prior to commencement of work and must comply with all applicable federal, state, and local laws and ordinances, including mandatory notification procedures should any cultural resources be discovered during construction.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Specifications.pdf | ||
| Proposal and Affidavit.pdf | ||
| QA QC Plan.pdf | ||
| Bid Bond.pdf | ||
| H & H Report.pdf | ||
| Schedule of Prices.pdf | ||
| Notice to Bidders.pdf | ||
| Proposal and Affidavit - REVISED.pdf | ||
| Addendum 1 & Pre-bid.pdf | ||
| General Requirements.pdf | ||
| Schedule of Prices - REVISED.pdf |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
227TH ST
V A
N M
ET
ER
A V
E
TU
C
KE
R
A V
E
220TH ST
V A
IL
A
V E
XI
RC
US
A
V E
190TH ST
210TH ST
W
ILS
O N
A V
E
UB
BE
N A
V E
XI
RC
US
A
V E
200TH ST
UB
BE
N A
V E
210TH ST
YO
UN
G A
V E
YO
UN
G A
V E
V A
IL
A
V E
V A
IL
A
V E
220TH ST
190TH ST
190TH ST
WILLIAMS
T-
N
W I L L I A M S
1314151617
20 21 22 23 24
33 34 35 36
234561
D23
D20
R77
D25
R75
D20 D20
A27.1
A15.5 A15.2
26390
602555
POP.
C H
IC
AG
O , C
EN
TR
AL
PA
C
IF
IC
R .R
. C O
‒‒147
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c h:
\h am ilt on
_c o_ ia \0 a1
\C
AD
\C 3D
\P et er so n\
A0 1.
dw g
1/
/2
:2 8:
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV HAMILTON COUNTY, IOWA
HAM892326B NUTRIENT REDUCTION WETLAND
BCS
NVD
JPR
0A1.127685
1.1 BID PLANS 01-22-2026
R
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.com
A.01
TITLE SHEET
PROJECT DATUM: STATE PLANE
HORIZONTAL: IOWA NORTH
VERTICAL: NAVD 1988
MY LICENSE RENEWAL DATE IS
PAGES OR SHEETS COVERED BY THIS SEAL:
LICENSE NUMBER: DATE:
I OWA
LI
CE
NS
ED
PROFESS IONAL ENG
INEER
I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS
PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION
AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER
UNDER THE LAWS OF THE STATE OF IOWA.
29449
12/31/2026
ALL SHEETS
BRANDON C.
SHORT
29449
BRANDON C. SHORT, PE
HAMILTON COUNTY, IA
CONSTRUCTION PLANS FOR
IDALS NO. HAM892326B
NUTRIENT REDUCTION WETLAND
HAMILTON COUNTY, IOWA
JANUARY 2026
THE SPECIFICATIONS AS PREPARED BY IOWA DEPARTMENT OF AGRICULTURE
AND LAND STEWARDSHIP AND BOLTON & MENK, INC. SHALL BE CONSIDERED
AS PART OF THIS DOCUMENT. NATURAL RESOURCES CONSERVATION SERVICE
CONSTRUCTION SPECIFICATIONS SHALL APPLY.
THE CURRENT EDITION OF THE "IOWA STATEWIDE URBAN STANDARD
SPECIFICATIONS FOR PUBLIC IMPROVEMENTS" SHALL GOVERN.
IOWA DEPARTMENT OF TRANSPORTATION "STANDARD SPECIFICATIONS FOR
HIGHWAY AND BRIDGE CONSTRUCTION" AND ALL CURRENT GENERAL
SUPPLEMENTAL SPECIFICATIONS AND MATERIALS INSTRUCTIONAL
MEMORANDUM SHALL GOVERN AS REFERENCED.
ALL APPLICABLE FEDERAL, STATE, AND LOCAL LAWS AND ORDINANCES WILL BE
COMPLIED WITH IN THE CONSTRUCTION OF THIS PROJECT.
GOVERNING SPECIFICATIONS
THE SUBSURFACE UTILITY INFORMATION IN THIS PLAN IS
UTILITY QUALITY LEVEL D. THIS UTILITY QUALITY LEVEL WAS
DETERMINED ACCORDING TO THE GUIDELINES OF CI/ASCE
38-02, ENTITLED "STANDARD GUIDELINES FOR THE
COLLECTION AND DEPICTION OF EXISTING SUBSURFACE
UTILITY DATA."
THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING IOWA
ONE CALL BY PHONE AT 811, OR ON THE WEB AT
HTTP://WWW.IOWAONECALL.COM/. TICKET# ___________.
TICKET NUMBER MUST BE PROVIDED TO THE NRCS PRIOR TO
COMMENCEMENT OF WORK.
NOTES
1. IF A CULTURAL RESOURCE IS IDENTIFIED DURING
CONSTRUCTION, STOP WORK IMMEDIATELY AND NOTIFY
THE LOCAL NATURAL RESOURCES CONSERVATION SERVICE
OFFICE.
2. THERE IS NO GUARANTEE THAT THE WETLAND WILL FILL OR
REMAIN FILLED WITH WATER.
R-23W
T-
N
PROJECT
LOCATION
R-23W
T-
N CONSERVATION PRACTICE STANDARDS USED:
656 - CONSTRUCTED WETLAND
NRCS JOB CLASS: IV
300 AC<WATERSHED AREA<1000 AC
TO THE BEST OF MY PROFESSIONAL KNOWLEDGE,
JUDGEMENT, AND BELIEF, THESE PLANS MEET APPLICABLE
NRCS STANDARDS AND APPLICABLE LAWS AND
REGULATIONS.
CLIENT ACCEPTANCE
SIGNATURE DATE
SHEET LIST TABLE
SHEET NUMBER SHEET TITLE
A.01 TITLE SHEET
A.02 PLAN OVERVIEW SHEET
A.03 EXISTING CONDITIONS & REMOVALS
B.01 CPDT INSTALLATION DETAIL
B.02 RCP INSTALLATION DETAIL
B.03 WETLAND INLET STRUCTURE
B.04 WETLAND OUTLET STRUCTURE
C.01 ESTIMATED QUANTITIES
D.01 SEPARATION BERM PLAN & PROFILE
D.02 CONNECTION CHANNEL & DIVERSION BERM
K.01 SEEDING PLAN
M.01 PLAN AND PROFILE - TILE RELAYS
M.02 PARTIAL CAPTURE INLET & PRIVATE TILE
RE-LAY
M.03 WETLAND OUTLET
T-
N
T-
N brandon.short Text Box 01/22/2026
15" RCP
12" RCP
81 1182
117211731174
781179
MIDWEST OILSEEDS INC
MIDWEST OILSEEDS INC
MIDWEST OILSEEDS INC
SUMMIT FARMS ASSETS LLC
SUMMIT FARMS ASSETS LLC
GERALD & JANELLE PETERSON
JOEL & DEBBIE PETERSON
GERALD & JANELLE PETERSON
JOEL & DEBBIE PETERSON
GERALD & JANELLE PETERSON
JOEL & DEBBIE PETERSON
GERALD & JANELLE PETERSON
JOEL & DEBBIE PETERSON
MIDWEST OILSEEDS INC MIDWEST OILSEEDS INC MIDWEST OILSEEDS INC
11771178 11811182
11771178
CONNECT TO EXISTING TILE
ELEV. 1172.67
CONNECT TO EXISTING TILE
ELEV. 1172.50
FUTURE BORROW
POND BY OTHERS
PROPOSED EASEMENT BOUNDARY
CONNECT TO EXISTING TILE
ELEV. 1165
DAYLIGHT TILE 1171.50
SW-401 MANHOLE
INLET CHANNEL
TEMPORARY SURFACE FLOW CHANNEL
OUTLET STRUCTURE
MODIFIED SW-513
18" RCP
15" SMOOTH LINED CPDT
INLET STRUCTURE
MODIFIED SW-513
NWL 1170.50
12" RCP
OVERFLOW ELEVATION 1175
CONNECT TO EXISTING TILE
ELEV. 1175.10
PROPOSED SEPARATION BERM
CONSTRUCTION ACCESS
CONNECTION CHANNEL
SPOIL AREA
DIVERSION BERM
TOP ELEV. = 1170.50
EXISTING DISTRICT MAIN TILE
10" DIA. CLAY
EXISTING DISTRICT BRANCH TILE
12" DIA. CLAY
EXISTING PRIVATE TILE
12" DIA.
EXISTING DISTRICT TILE
18" DIA. CLAY
BENCHMARK 60000
BENCHMARK 60012
BENCHMARK 60011
BENCHMARK 60010
BENCHMARK 60008
NORMAL POOL (1170.50)
100-YEAR HWL (1175.31)
PROPOSED EASEMENT BOUNDARY
EXCAVATE TO 1169.50
FLOW PATH THROUGH WETLAND
LEGEND
SHEET
B ol to n
M en k, In c.
5, A ll Ri gh ts
R es er ve d c h:
\h am ilt on
_c o_ ia \0 a1
\C
AD
\C 3D
\P et er so n\
A0 2.
dw g
1/
/2
:2 9:
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV HAMILTON COUNTY, IOWA
HAM892326B NUTRIENT REDUCTION WETLAND
BCS
NVD
JPR
0A1.127685
1.1 BID PLANS 01-22-2026
R
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.com PLAN OVERVIEW SHEET
R
FEETSCALE
0 150 300
HORZ. A.02
BENCHMARK NO. NORTHING EASTING DESCRIPTION
60000 3645311.12 4913536.06 LMFR /SCR 34IN
60008 3642649.16 4913546.24 LMFR /SCR MCAP 15745
60010 3644660.40 4913538.68 LMFR /34 LEAN N
60011 3644968.05 4913537.44 LMFR /58 OPC 15745
60012 3645278.06 4913536.18 LMFR /58 OPC 15745
DESIGN CRITERIA VALUE UNIT REQUIREMENT
WATERSHED AREA 605 ACRES
POOL NORMAL WATER LEVEL (NWL) ELEV 1170.50 FT
DESIGNED WETLAND POOL AREA (@ NWL) 6.5 ACRES
PERCENT POOL AREA TO WATERSHED AREA 1.1 % Range 0.5% to 2% of watershed area
MAXIMUM POOL DEPTH 1.0 FT
AVERAGE POOL DEPTH 1.0 FT
DEEP WATER AREA (DEPTH > 3 FT) 0.0 ACRES
PERCENT DEEP WATER TO POOL AREA 0.0 % Less than 25%
POOL STORAGE VOLUME AT NWL 3.1 ACRE-FT
OVERFLOW ELEVATION 1174.25 FT Natural Berm
POOL STORAGE VOLUME AT OVERFLOW 53.0 ACRE-FT
PRIMARY WEIR ELEVATION 1170.50 FT Conveys Tile Flow Only PRIMARY WEIR WIDTH 4 FT SUDAS SW-513 Outlet Structure
TOTAL EASEMENT AREA 26.5 ACRES
AREA OF BUFFER 20.0 ACRES
RATIO BUFFER AREA TO NWL POOL AREA 3.1 Less than 4
AVERAGE CAPTURE FLOW CFS
25-YEAR STORM HWL IN POOL 1175.76 FT
25-YEAR PEAK INFLOW 621 CFS
25-YEAR PEAK OUTFLOW 624.00 CFS
100-YEAR STORM HWL IN POOL 1176.02 FT
100-YEAR PEAK INFLOW 864 CFS
100-YEAR PEAK OUTFLOW 868 CFS
MIDWEST OILSEEDS INC
MIDWEST OILSEEDS INC
MIDWEST OILSEEDS INC
SUMMIT FARMS ASSETS LLC
SUMMIT FARMS ASSETS LLC
GERALD & JANELLE PETERSON
JOEL & DEBBIE PETERSON
GERALD & JANELLE PETERSON
JOEL & DEBBIE PETERSON
GERALD & JANELLE PETERSON
JOEL & DEBBIE PETERSON
GERALD & JANELLE PETERSON
JOEL & DEBBIE PETERSON
MIDWEST OILSEEDS INC MIDWEST OILSEEDS INC MIDWEST OILSEEDS INC
MIDWEST OILSEEDS INC
MIDWEST OILSEEDS INC
MIDWEST OILSEEDS INC
EXISTING STORM BOUNCES
GREEN: 5-YEAR (1175.43)
ORANGE: 10-YEAR (1175.58)
YELLOW: 25-YEAR (1175.76)
PURPLE: 100-YEAR (1176.03)
EXPOSE, CRUSH AND BURY
EXISTING TILE
PROPOSED EASEMENT BOUNDARY
EXPOSE, CRUSH AND BURY
EXISTING TILE
EXPOSE, CRUSH AND BURY
EXISTING TILE
NOTES:
1. ALL CLAY TILES TO BE DEMOLISHED MAY BE REMOVED OR CRUSHED IN PLACE.
2. PLASTIC TILES SHALL BE REMOVED AND DISPOSED OF WHERE BROKEN.
3. ALL TILE SHALL BE DESTROYED THROUGH WETLAND POOL.
EXISTING TILE
FLOW LINE ELEV. = 1168.51
TOP OF PIPE = 1169.20
EXISTING TILE
FLOW LINE ELEV. = 1173.86
TOP OF PIPE = 1174.96
EXISTING TILE
FLOW LINE ELEV. = 1167.59
EXISTING TILE
FLOW LINE ELEV. = 1166.04
EXISTING TILE
FLOW LINE ELEV. = 1165.42
PROPOSED EASEMENT BOUNDARY
TILE REMOVAL
LEGEND
SHEET
B ol to n
M en k, In c.
5, A ll Ri gh ts
R es er ve d c h:
\h am ilt on
_c o_ ia \0 a1
\C
AD
\C 3D
\P et er so n\
A0 3.
dw g
1/
/2
:3 1:
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV HAMILTON COUNTY, IOWA
HAM892326B NUTRIENT REDUCTION WETLAND
BCS
NVD
JPR
0A1.127685
1.1 BID PLANS 01-22-2026
R
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.com
R
FEETSCALE
0 150 300
HORZ.
EXISTING CONDITIONS & REMOVALS
A.03
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c h:
\h am ilt on
_c o_ ia \0 a1
\C
AD
\C 3D
\P et er so n\
B0 1.
dw g
1/
/2
:3 1:
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV HAMILTON COUNTY, IOWA
HAM892326B NUTRIENT REDUCTION WETLAND
BCS
NVD
JPR
0A1.127685
1.1 BID PLANS 01-22-2026
R
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.com
B.01
CPDT INSTALLATION DETAIL
FLAT BOTTOM TRENCH INSTALLATION
FILL TRENCH TO 6" ABOVE TOP OF PIPE WITH CRUSHED STONE OR GRAVEL
MEETING THE REQUIREMENTS IN TABLE 2. BEDDING MATERIAL SHALL BE
INCIDENTAL TO THE PIPE INSTALLATION.
PREFFERED TRENCH INSTALLATION BOTTOM
CORRUGATED POLYETHYLENE DRAINAGE TUBING
MATERIAL & INSTALLATION NOTES
NOT TO SCALE
SOURCE: ASTM F449
TRAPEZOIDAL GROOVE, "V" GROOVE, & CIRCULAR GROOVE
NOT TO SCALE
SOURCE: ASTM F449
6" MIN FOR
OPEN TRENCH
INSTALLATION
R
6" M
IN
A B G
0.
5R
0.
R
TRENCH WIDTH MEASURED
AT TOP OF PIPE
90° "V" GROOVE
90°
THE CIRCULAR GROOVE SHALL BE A
MINIMUM 0.35R DEEP AND SHALL
MATCH THE OUTSIDE CURVE
SHAPE OF THE DEFLECTED CPDT.
THE TRAPEZOIDAL GROOVE SHALL
BE SHAPED AND ADJUSTED SUCH
THAT POINTS A, B, & C WILL TOUCH
THE UNDEFLECTED CPDT FOR EACH
SIZE INSTALLED.
TRAPEZOIDAL GROOVE
CIRCULAR GROOVE
UNDISTURBED SOIL
UNDISTURBED SOIL
TRENCH WIDTH MEASURED
AT TOP OF PIPE
4" M
IN
SEE TABLE 2 FOR
BEDDING MATERIAL
NOTE: THIS IS AN ALLOWED ALTERNATIVE INSTALLATION FOR CPDT
1. ALL CPDT AND CONNECTORS FURNISHED SHALL BE IN COMPLIANCE WITH MATERIAL STANDARDS ASTM F405 AND F667, AS
APPLICABLE, AND SHALL BE CLASSIFIED AS HEAVY-DUTY UNDER THOSE STANDARDS.
2. EXCEPT MODIFIED HEREIN OR OTHERWISE APPROVED BY ENGINEER, ALL CPDT SHALL BE INSTALLED IN COMPLIANCE WITH THE
ASTM 449 STANDARD PRACTICE.
3. FOR PIPES 6” DIAMETER AND SMALLER A 90° V GROOVE BOTTOM MAY BE USED, FOR ALL LARGER PIPE A TRAPEZOIDAL BOTTOM OR A CIRCULAR BOTTOM CONFORMING TO THE OUTSIDE DIAMETER OF THE PIPE SHALL BE USED. PRIOR TO THE INSTALLATION OF CPDT, CONTRACTOR MUST PROVE TO ENGINEER THAT THE INSTALLATION REQUIREMENTS, INCLUDING THE
SHAPE OF THE TRENCH BOTTOM, WILL BE ACCOMPLISHED.
4. WHERE TRENCH BOTTOM IS IN FIRM UNDISTURBED SOIL, SHAPE TRENCH BASE GROOVE. WHERE EXCESS CUT OCCURS, OVEREXCAVATE AND PLACE MINIMUM THREE (3) INCH THICK, GRAVELLY SAND BEDDING TO RESTORE GRADE. THIS BEDDING SHALL MEET THAT REQUIRED FOR TRENCH INSTALLATION TYPE 3 ON PLAN SHEET C.02. IF DUE TO CONTRACTOR ERROR THIS MATERIAL AND WORK IS SUBSIDIARY TO THE INSTALLATION OF THE PIPE. CONTRACTOR MAY SUBSTITUTE PIPE BEDDING ROCK
AS THE BEDDING MATERIAL.
5. NATIVE SOILS MAY BE USED AS BACKFILL MATERIAL UNLESS UNSTABLE TRENCH CONDITIONS PREVENT THE TRENCH BOTTOM HOLDING THE SHAPED GROOVE. IF TRENCH BOTTOM WILL NOT HOLD GROOVE SHAPE CONTRACTOR SHALL NOTIFY ENGINEER IMMEDIATELY. A FLAT BOTTOM TRENCH INSTALLATION WILL THEN BE ASSUMED. THE REQUIRED BEDDING MATERIAL WILL BE
PAID UNDER THE TILE TRENCH STABILIZATION AND CRADLING ROCK BID ITEM.
6. MINIMUM TRENCH WIDTH IS PIPE OUTSIDE DIAMETER PLUS FOUR (4) INCHES FOR PLOWED INSTALLATION AND PIPE OUTSIDE
DIAMETER PLUS TWELVE (12) INCHES FOR OPEN TRENCH INSTALLATION.
7. ALL LATERAL CONNECTIONS, ELBOWS, TEES, ALIGNMENT CURVES, START HOLES AND ALL PORTIONS OF THE TRENCH NOT MEETING THE GROOVED TRENCH INSTALLATION REQUIREMENTS SHALL BE FILLED TO A MINIMUM OF SIX (6) INCH COVER OVER THE PIPE WITH GRADED CRUSHED STONE OR GRAVEL AS SHOWN ON TABLE 2 OF THIS SHEET. UNLESS DUE TO CONTRACTOR ERROR THIS BEDDING MATERIAL WILL BE PAID UNDER THE TILE TRENCH STABILIZATION AND CRADLING ROCK BID ITEM.
8. MANUFACTURER'S ENDCAPS SHALL BE INSTALLED AT THE TERMINATION OF EACH LINE UNLESS A CONNECTION TO AN EXISTING
DRAIN IS MADE.
9. WITH THE INSTALLATION OF THE FIRST REACH OF CPDT ON THE PROJECT, CONTRACTOR IS REQUIRED TO WORK WITH THE
ENGINEER TO CHECK AND CONFIRM THAT THE PIPE STRETCH, IF ANY, DOES NOT EXCEED 5%.
10. ALIGNMENT TURNS MAYBE MADE USING EITHER A MANUFACTURED FITTING OR CURVING THE LINE WITH A 25' MINIMUM
RADIUS.
R25'
PI
X °
PT
PT
Table 1 Maximum Allowable Buried Depth to Flowline of CPDT
Nominal Pipe Diameter (IN)
Pipe Quality
(ASTM)
Trench Width at Top of the Pipe (FT)
12" 18" 24" 30" or Greater
Standard 13 7 5.5 5
Heavy-duty Any 10 7 6
Standard 10 7 5.5 5
Heavy-duty Any 9.5 6.5 6
Standard 10 7 5.5 5
Heavy-duty Any 10 7 6
10 Heavy-duty ... 9 7 6 12 Heavy-duty ... 9 7 6 15 Heavy-duty ... ... 7 6
Table 2 Acceptable Bedding Material and Compaction Requirements
Description Percentage Passing Sieve Sizes Minimum
Standard Density (%)
Maximum Compaction Layer Height
(IN.)1" 3/4" No. 4
Crushed Stone Crushed Gravel* 100% > 95% < 5% Dumped 18
* Class 1 Bedding Material Per SUDAS 3010.202A is an Allowable Substitute
DEGREES Δ DELTA
20° 4.41 30° 6.7 45° 10.36 60° 14.43 70° 17.51 80° 20.98 90° 25 ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c h:
\h am ilt on
_c o_ ia \0 a1
\C
AD
\C 3D
\P et er so n\
B0 1.
dw g
1/
/2
:3 1:
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV HAMILTON COUNTY, IOWA
HAM892326B NUTRIENT REDUCTION WETLAND
BCS
NVD
JPR
0A1.127685
1.1 BID PLANS 01-22-2026
R
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.com
B.02
RCP INSTALLATION DETAIL
TRENCH INSTALLATION TYPE 3
COMPLETELY FILL
HAUNCH AREA WITH
GRAVELLY SAND
COMPACT TO 85%
STANDARD PROCTOR
DENSITY.
Do
LOOSELY PLACED UNCOMPACTED
GRAVELLY SAND BEDDING
Do/3
3" MIN.
PIPE SPRINGLINE
GRAVELLY SAND BEDDING SHALL BE CONSISTENT WITH THE GRADATION AND
OTHER CHARACTERISTICS OF STANDARD AASHTO A1 OR A3 SOIL. A
REPRESENTATIVE SAMPLE OF THE MATERIAL AND A GRADATION REPORT OR
SUPPLIER'S CERTIFICATION OF COMPLIANCE SHALL BE SUBMITTED TO THE
ENGINEER FOR APPROVAL PRIOR TO DELIVERY TO SITE. SEE SOIL DATA IN
APPENDIX OF SPECIFICATIONS BOOKLET.
6" TYP
0" MIN MEASURE POINT FOR
MAXIMUM TRENCH WIDTH
TOP OF
PIPE
CRUSHED ROCK MEETING THE GRADATION OF SUDAS CLASS I BEDDING
MATERAL, SPECIFICATION SECTION 3010.2.02.A, MAY BE SUBSTITUTED FOR
THE SAND OR CLAY HAUNCH BACKFILL MATERIAL. NO COMPACTION WILL BE
REQUIRED FOR THE CRUSHED ROCK BEDDING AND BACKFILL. MATERIAL
COSTS SHALL BE INCIDENTAL TO PIPE INSTALLATION.
MODIFIED TRENCH INSTALLATION TYPE 4
COMPLETELY FILL HAUNCH
AREA WITH NON-SATURATED
SILTY CLAY OR CLAY SOIL.
COMPACT TO 85% STANDARD
PROCTOR DENSITY. THERE
ARE NO SPECIFIED MOISTURE
LIMITS.
Do
WHERE TRENCH BOTTOM IN FIRM UNDISTURBED SOIL,
SHAPE TRENCH BASE GROOVE TO MATCH MINIMUM
1/6 OF THE OUTER CIRCUMFERENCE OF THE PIPE.
WHERE THE SHAPED GROOVE CANNOT BE
CONSTRUCTED INTO UNDISTURBED GROUND OR
WHERE EXCESS CUT OCCURS OVER EXCAVATE AND
PLACE MINIMUM 3-INCH THICK COMPACTED GRAVELLY
SAND BEDDING TO RESTORE GRADE SUCH THAT 1/6 OR
MORE OF THE OUTER CIRCUMFERENCE OF THE PIPE IS
BEDDED. THIS MATERIAL AND WORK IS SUBSIDIARY TO
THE INSTALLATION OF THE PIPE. CONTRACTOR MAY
SUBSTITUTE PIPE BEDDING ROCK AS THE BEDDING
MATERIAL. IT ALSO IS SUBSIDIARY.
PIPE SPRINGLINE
6" TYP
0" MIN MEASURE POINT FOR
MAXIMUM TRENCH WIDTH
TOP OF
PIPE
MINIMUM TRENCH WIDTH SHALL BE OUTSIDE DIAMETER OF PIPE PLUS 12" OR
THAT WIDTH WHICH IS REQUIRED FOR COMPACTION, WHICHEVER IS GREATER
WHERE FIRM BASE IS NOT
ENCOUNTERED. OVER
EXCAVATE AS DIRECTED BY
ENGINEER. PLACE CRADLING
ROCK AND BED PIPE IN IT
SUCH THAT 1/6 OR MORE OF
THE OUTER CIRCUMFERENCE
OF THE PIPE IS SUPPORTED.
THIS ROCK IS PAID FOR UNDER
A SEPARATE BID ITEM.
THE CONTRACTOR IS SOLEY RESPONSIBLE FOR THE INSTALLATION OF ALL PIPE ACCORDING TO PLAN REQUIREMENTS.
THE CONTRACTOR'S PARTICIPATION IN AND COMPLIANCE WITH THE FOLLOWING PROCEDURE IS REQUIRED AND WILL
ALLOW FOR FEWER SOIL DENSITY TESTS TO ENSURE PROPER PIPE INSTALLATION.
STEP 1
BEFORE COMMENCING PIPE INSTALLATION, STANDARD SOIL PROCTOR DENSITY TEST RESULTS OF REPRESENTATIVE SAMPLE(S) OF PIPE HAUNCH FILL SHALL BE PROVIDED BY AN INDEPENDENT QUALIFIED SOILS TESTING LAB. THE SELECTION OF THE SAMPLE(S) WILL BE MADE BY THE ENGINEER AND CONTRACTOR (WHEN SPECIFIED).
STEP 2
CONTRACTOR MAY BEGIN EXCAVATING THE MODIFIED TYPE 4 TRENCH
WITH THE REQUIRED SHAPED BOTTOM GROOVE AND PLACE SEVERAL PIPE SECTIONS ONLY WHEN BOTH ENGINEER AND
TESTING LAB TECHNICIAN ARE PRESENT
CONTRACTOR SHALL DEMONSTRATE THE INTENDED METHODS FOR COMPACTING THE FILL FOR THE PIPE HAUNCH AREAS. SOIL DENSITY TESTS SHALL BE TAKEN AT LOCATIONS DESIGNATED BY THE ENGINEER TO CONFIRM THAT THE INTEDNED METHODS FOR FILL AND COMPACTION OF THE PIPE HAUNCH AREAS SATIFIES THE PLAN REQUIREMENTS.
CONTRACTOR SHALL MODIFIY THE INSTALLATION METHODS AND REPEAT STEP 2 UNTIL ACCEPTABLE TESTS RESULTS ARE
ACHIEVED.
STEP 3
CONTRACTOR MAY INSTALL THE NEXT SEVERAL HUNDRED FEET OF PIPE. ENGINEER SHALL DESIGNATE SEVERAL LOCATIONS (APPROXIMATELY 10% OF THE INSTALLED LENGTH) WHERE CONTRACTOR SHALL LEAVE THE PIPE UNBLINDED FOR FURTHER DENSITY TESTS OF THE HAUNCH FILL AREA. ALL DENSITY TESTS MUST MEET PLAN REQUIREMENTS BEFORE
WORK MAY PROCEED FURTHER.
IF DENSITY TESTING DATA CONFIRMS TO THE SATISFACTION OF THE ENGINEER THAT THE CONTRACTOR'S INSTALLATION METHOD WILL PRODUCE CONSISTENT COMPLIANCE WITH PLAN REQUIREMENTS, CONTRACTOR MAY CONTINUE INSTALLATION OF THE PIPE WITH NO ADDITIONAL TESTING REQUIRED. IF NOT, STEPS 2 AND 3 SHALL BE REPEATED UNTIL A RELIABLE, SUCCESSFUL METHOD OF PIPE INSTALLATION THAT PRODUCES SATISFACTORY RESULTS IS ESTABLISHED.
TRENCH WALLS
PLUG DOWNSTREAM
TILE WITH PLASTIC END
PLUG, CONCRETE, OR
AS OTHERWISE
ALLOWED.FLOW FLOW
CUT AND SHAPE END OF P.E.
TILE TO FIT FLUSH WITH INSIDE
OF CONCRETE TILE. GROUT
CONNECTION
FILL TRENCH TO P.E. SPRINGLINE WITH COMPACTED CRUSHED
STONE. WHERE COVER EXCEEDS 8 FEET, COVER CONNECTION
AND EXPOSED P.E. WITH 12 INCHES OF CRUSHED STONE
BEDDING COMPLYING WITH SUDAS SPECIFICATION SECTION
3010.301. BUCKET PRESS & COMPACT EARTH FILL UNIFORMLY
ON BOTH SIDES OF STONE TO RESIST LATERAL MOVEMENT OF
THE STONE.
CONCRETE COLLAR EXCEPTION
CONNECTIONS TO THE PIPE AT BOTH ENDS MAY BE MADE
WITH A MANUFACTURED POLYETHYLENE INTERNAL SNAP
COUPLER INSERTED FULLY INTO THE PIPE. CONCRETE COLLARS
NOT REQUIRED WITH POSITIVE LOCKED CONNECTION OR
WHERE COMPACTED CRUSHED ROCK FULLY SURROUNDS THE
CONNECTION. GAPS AT THE CONNECTIONS SHALL BE COVERED
WITH ENGINEERING FABRIC WRAPPED AROUND THE JOINT.
INSERTA TEE WILL BE CONSIDERED AS ALTERNATE
CONNECTION AT NEW MAIN WITH ENGINEERS PRIOR
APPROVAL AND INSTALLATION PER MANUFACTURERS
RECOMMENDATION.
TYPICAL FIELD TILE CONNECTION
FOR FIELD TILE UP TO 10" DIAMETER
CO
VE
R
USE NON-PERFORATED
CORRUGATED P.E. DRAIN TILE
UNDISTURBED
SOIL
SLIDE CORRUGATED P.E. TILE A
MINIMUM OF 6" OVER END OF
EXISTING TILE. ENCASE JOINT (IF
NOT TIGHT FITTING) IN P.C.
CONCRETE COLLAR, AS SHOWN.
FIELD TILE
A
A
PIPE HAUNCH FILL AND COMPACTION METHOD
PLAN REQUIREMENTS COMPLIANCE VERIFICATION
12"
6"
HAND SHAPE TRENCH FOR P.E.
TILE TO INSURE UNDISTURBED
SOIL SUPPORT LOWER 1/2 OF
TILE PERIMETER OR BED ON
CRUSHED STONE FILL AND
THOROUGHLY TAMP SOIL
ENVELOPE
SECTION A-A
TOP OF SOIL
ENVELOPE
UNDISTURBED
SOIL
CONTRACTOR IS REQUIRED TO PROPERLY AND ADEQUATELY INSTRUCT SUBCONTRACTORS AND/OR SUBSEQUENT PIPE
INSTALLATION WORKERS ON THE PROPER INSTALLATION METHOD.
STEP 4A
SOIL OR TRENCH CONDITION CHANGES
TO VERIFY CONTRACTOR'S COMPLIANCE WITH PLAN REQUIREMENTS UNDER THE CHANGED CONDITIONS, ENGINEER MAY STOP WORK AND REQUIRE ADDITIONAL SOIL PROCTOR TESTS AND/OR SOIL DENSITY TESTS SIMILAR TO STEPS 1 THROUGH
3. THE WORK AND COSTS OF THE FIRST TWO REVERIFICATIONS IS SUBSIDIARY TO THE PIPE INSTALLATION. SUBSEQUENT
VERIFICATIONS WILL BE CONSIDERED EXTRA WORK.
STEP 4B
CONTRACTOR FAILS TO CONSISTENTLY PERFORM INSTALLATION METHOD OR INSTRUCT OTHER INSTALLERS
IF CONTRACTOR FAILS TO CONSISTENTLY PERFORM OR ADEQUATELY INSTRUCT SUBCONTRACTORS AND/OR SUBSEQUENT PIPE INSTALLATION WORKERS ON THE APPROVED INSTALLATION METHOD, ENGINEER MAY STOP WORK AND REQUIRE ADDITIONAL SOIL PROCTOR TESTS AND/OR SOIL DENSITY TESTS SIMILAR TO STEPS 1 THROUGH 3 TO VERIFY CONTRACTOR'S COMPLIANCE WITH PLAN REQUIREMENTS. THE WORK AND COSTS OF ALL VERIFICATIONS UNDER SUCH
CONDITIONS IS SUBSIDIARY TO THE PIPE INSTALLATION.
EXCEPTION
IF CONTRACTOR ELECTS TO SHAPE THE TRENCH BOTTOM SUCH THAT A MINIMUM OF 45% OF THE OUTER CIRCUMFERENCE OF THE PIPE IS FIRMLY BEDDED IN AND CONSISTENTLY SUPPORTED BY UNDISTURBED SOIL, PIPE HAUNCH FILL COMPACTION TESTING WILL NOT BE REQUIRED. THE CONTRACTOR IS REQUIRED TO COMPLY WITH A PROPER INSTALLATION METHOD AND TO FULLY COMPLY WITH THE REQUIREMENTS OF THE VERIFICATION OUTLINED
ABOVE FOR ALL SITUATIONS WHERE THIS EXCEPTION IS NOT MET.
NOT TO SCALE
SOURCE: AMERICAN CONCRETE PIPE ASSOCIATION
CONCRETE PIPE DESIGN MANUAL
NOT TO SCALE
SOURCE: AMERICAN CONCRETE PIPE ASSOCIATION
CONCRETE PIPE DESIGN MANUAL
ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c h:
\h am ilt on
_c o_ ia \0 a1
\C
AD
\C 3D
\P et er so n\
B0 1.
dw g
1/
/2
:3 1:
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV HAMILTON COUNTY, IOWA
HAM892326B NUTRIENT REDUCTION WETLAND
BCS
NVD
JPR
0A1.127685
1.1 BID PLANS 01-22-2026
R
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.com
B.03
WETLAND INLET STRUCTURE
SECTION
MODIFIED SW-513
INLET STRUCTURE
BOLT ON 38" STEEL WEIR PLATE WITH 38"
GALVANIZED STEEL EXPANSION ANCHORS
PROVIDE EXTERIOR GRADE SEALANT
BEHIND WEIR PLATE
SEE SHEET SUDAS FOR SW-513 DETAILS
PRECAST STRUCTURE SHALL BE ONE SECTION OR
PROVIDE WATERTIGHT SEAL BETWEEN SECTIONS.
TOP OF STRUCTURE ELEVATION (SEE PROFILE)
WEIR CREST ELEVATION (SEE PROFILE)
PRECAST OPENING ELEVATION
47-1/2" x 47-1/2" x 1.5" GALVANIZED STEEL
GRATE TOP. BOLT TO STEEL ANGLE AT ALL 4
CORNERS WITH 38" BOLTS, WASHERS AND NUTS.
GALVANIZED STEEL ANGLE L 2x2x1 4 , ANCHOR TO WALL WITH 38" EXPANSION
ANCHORS, SPACED 8" APART. TYPICAL 3
SIDES OF STRUCTURE.
BOLT GALVANIZED STEEL GRATE TO
GALVANIZED STEEL ANGLE AT EACH
PLAN
MODIFIED SW-513
INLET STRUCTURE
B.03
" W
AL
L
W
ID
TH
48" WALL WIDTH
58"
1.
0'
1.
NOT TO SCALE
NOT TO SCALE
6" SUMP
FL ELEV (SEE PROFILE)
SEE SUDAS FOR SW-513 DETAILS
INLET PIPE
7 FT x 7 FT x 1.5 FT DEEP RIP RAP (4.1 TN)
WITH GEOTEXTILE
NOTES:
1. BAR GRATE SHALL BE McNICHOLS HEAVY DUTY
WELDED GHB-100, 19 W-4, OR APPROVED EQUAL.
2. ALL FASTENERS SHALL BE GALVANIZED OR
STAINLESS STEEL.
3. WEIR PLATE, STEEL GRATE, AND ALL HARDWARE
AND APPURTENANCES SHOWN ON THIS PAGE OR
REQUIRED FOR INSTALLATION ARE SUBSIDIARY TO
THE INLET STRUCTURE.
BEDDING PER SUDAS
48" WALL WIDTH
1'
*CUT OPENING FOR VALVE HANDLE ACCESS
EXCAVATED WETLAND POOL
PROVIDE FLEXIBLE, WATERTIGHT GASKET FOR PIPE OPENINGS
ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c h:
\h am ilt on
_c o_ ia \0 a1
\C
AD
\C 3D
\P et er so n\
B0 1.
dw g
1/
/2
:3 1:
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV HAMILTON COUNTY, IOWA
HAM892326B NUTRIENT REDUCTION WETLAND
BCS
NVD
JPR
0A1.127685
1.1 BID PLANS 01-22-2026
R
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.com
B.04
WETLAND OUTLET STRUCTURE
SHEET STEEL
SHEET STEEL
SHEET STEEL
1 - STEEL SHEET - 60" x 24" x 3/8" 2 - STEEL SHEETS - 72" x 24" x 3/8"
ANGLE IRON--EITHER WELDED OR BOLTED--ON TOP AND BOTTOM OF EACH SHEET AS BRACE
BOLT TRASH GUARD ONTO OUTLET STRUCTURE
GRADE AS NECESSARY TO ALLOW FLOW OF WATER UNDER TRASH GUARD WITH 6" MINIMUM CLEARANCE
60"
OUTLET
WEIR
TRASH GUARD FOR WETLAND OUTLET STRUCTURE
PROVIDE FLEXIBLE, WATERTIGHT GASKET FOR PIPE OPENINGS
GROUND
CONTACT
TREATED POST
4"x4"
SECTION
MODIFIED SW-513
OUTLET STRUCTURE
BOLT ON 38" STEEL WEIR PLATE WITH 38"
GALVANIZED STEEL EXPANSION ANCHORS
PROVIDE EXTERIOR GRADE SEALANT
BEHIND WEIR PLATE
SEE SHEET SUDAS FOR SW-513 DETAILS
PRECAST STRUCTURE SHALL BE ONE SECTION OR
PROVIDE WATERTIGHT SEAL BETWEEN SECTIONS.
TOP OF STRUCTURE ELEVATION (SEE PROFILE)
WEIR CREST ELEVATION (SEE PROFILE)
PRECAST OPENING ELEVATION
47-1/2" x 47-1/2" x 1.5" GALVANIZED STEEL
GRATE TOP. BOLT TO STEEL ANGLE AT ALL 4
CORNERS WITH 38" BOLTS, WASHERS AND NUTS.
GALVANIZED STEEL ANGLE L 2x2x1 4 , ANCHOR TO WALL WITH 38" EXPANSION
ANCHORS, SPACED 8" APART. TYPICAL 3
SIDES OF STRUCTURE.
BOLT GALVANIZED STEEL GRATE TO
GALVANIZED STEEL ANGLE AT EACH
PLAN
MODIFIED SW-513
OUTLET STRUCTURE
B.03
" W
AL
L
W
ID
TH
48" WALL WIDTH
58"
1.
0'
1.
NOT TO SCALE
NOT TO SCALE
6" SUMP
FL ELEV (SEE PROFILE)
SEE SUDAS FOR SW-513 DETAILS
OUTLET PIPE
7 FT x 7 FT x 1.5 FT DEEP RIP RAP (4.1 TN)
WITH GEOTEXTILE
NOTES:
1. BAR GRATE SHALL BE McNICHOLS HEAVY DUTY WELDED
GHB-100, 19 W-4, OR APPROVED EQUAL.
2. INSTALL WITH ALL STOPLOGS IN PLACE.
3. ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS
STEEL.
4. DUAL-WALL HDPE, FIELD INTAKE, KNIFE/GATE VALVE,
WEIR PLATE, TRASH GUARD, STEEL GRATE, AND ALL
HARDWARE AND APPURTENANCES SHOWN ON THIS
PAGE OR REQUIRED FOR INSTALLATION ARE SUBSIDIARY
TO THE OUTLET STRUCTURE.
BEDDING PER SUDAS
48" WALL WIDTH
1'
12" DUAL-WALL HDPE
12" HICKENBOTTOM INTAKE
OR APPROVED EQUAL
3 LF 12" DUAL-WALL HDPE
12" HICKENBOTTOM INTAKE OR APPROVED EQUAL
12" 90° ELBOW
EXCAVATED WETLAND POOL
EXCAVATE 1 FT ADDITIONAL AROUND INTAKE
PLACE RIP RAP IN 3-FT DIA. CIRCLE AROUND INTAKE
UNDERLAY WITH GEOTEXTILE (0.6 TN)
PLACE RIP RAP IN 3-FT DIA. CIRCLE AROUND INTAKE
UNDERLAY WITH GEOTEXTILE (0.6 TN)
OUTLET
STRUCTURE
6" M
IN
SP
AC
E
BE
LO
W
GU
AR
D
NOT TO SCALE
60"
CONCRETE
FOOTINGS MIN
12" DIAMETER
3 FT
AGRI DRAIN IN-LINE
WATER LEVEL CONTROL
STRUCTURE OR
APPROVED EQUAL
ATTACH TO CONCRETE
STRUCTURE
7 FT x 7 FT x 1.5 FT DEEP RIP RAP (4.1 TN)
WITH GEOTEXTILE
FT
M
IN
EM
BE
DM
EN
T
AGRI DRAIN IN-LINE WATER LEVEL CONTROL
STRUCTURE OR APPROVED EQUAL
STUB IN 12" PIPE
BACKFILL MIN. 1 FT AROUND
WCS WITH 1" CLEAN ROCK
6" OVERLAP
GALVANIZED ANCHORS
ol to n
M en k, In c.
5, A ll Ri gh ts
R es er ve d c h:
\h am ilt on
_c o_ ia \0 a1
\C
AD
\C 3D
\P et er so n\
C0 1.
dw g
1/
/2
:3 1:
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV HAMILTON COUNTY, IOWA
HAM892326B NUTRIENT REDUCTION WETLAND
BCS
NVD
JPR
0A1.127685
1.1 BID PLANS 01-22-2026
R
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.com
C.01
ESTIMATED QUANTITIES
Bid Item Sub - Item Description
Specifications Plan No.
Estimated Quantities
No. Page Quantity Unit or Select
1 - Site Stripping & Preparation IA CS-001 1.0 LS 2 - Crop Damage IA CS-001 0.0 AC 3 - Structure & Channel Seeding IA CS-006 2.5 AC 4 - Buffer Seeding IA CS-006 0.4 AC 5 - Mobilization and Demobilization IA CS-008 1.0 LS 6 - Drain Tile Investigation and Removal IA CS-009 4 HR 7 - Excavation (General) IA CS-021 19671 CY 8 - Earthfill (General) IA CS-023 1464 CY 9 - Reinforced Concrete Pipe
A. 12" Diameter IA CS-031 1344 LF B. 15" Diameter IA CS-031 932 LF C. 18" Diameter IA CS-031 369 LF
10 - Smooth Lined CPDT Pipe (15" Diameter) IA CS-046 1579 LF 11 - Tile Connection - 10" Dia. or Smaller IA CS-046 1 EA 12 - Tile Connection - 12" Dia. or Larger IA CS-046 2 EA 13 - Modified SW-513 Inlet Structure IA CS-031 1 EA 14 - Modified SW-513 Outlet Structure IA CS-031 1 EA 15 - SW-401 Concrete Manhole Structure IA CS-031 1 EA 16 - Reinforced Concrete Apron, Footing, Bar Guard
A. 12" Diameter IA CS-031 2 EA B. 15" Diameter IA CS-031 1 EA
17 - Tied Concrete Block Mat IA CS-031 2350 SF 18 - Riprap (Class E) IA CS-061 33.3 TN
.9
.7
.6
.4
.4
.3
.0
.0
.0
.8
.5
.5
.5
.5
.5
.2
.5
.0
.5
.1
.5
.2
.5
.2
.5
.4
.5
.1
.5
.9
.5
.0
.5
.8
.5
.9
.5
.9
.5
.8
.5
.7
.5
.9
.5
.7
.5
.8
.5
.0
.5
.1
.5
.4
.5
.6
.0
.9
.0
.3
.5
.6
.6
.8
.0
0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 9+40
0.00% 0.00%2.00% 0.00% -2.00%
VPI: 1+43.30
EL: 1173.00
VPI: 1+75.00
EL: 1173.00
VPI: 7+91.20
EL: 1173.00
VPI: 2+00.00
EL: 1173.50
VPI: 7+50.00
EL: 1173.50
VPI: 7+75.00
EL: 1173.00
SEPERATION BERM
EXISTING GROUND
PROPOSED SEPARATION BERM
TOP ELEV = 1173.50
10 FT WIDE CONNECTION CHANNEL
3:1 SIDE SLOPES
VP
I:
4+
.3
EL
: 1
3.
VPI: 4+27.37
EL: 1170.50
VPI: 4+37.37
EL: 1170.50
VP
I:
4+
.3
EL
: 1
3.
0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 9+39.80
BP
: 0
+0 0.
EP
: 9
+3 9.
PROPOSED SEPARATION BERM
TOP ELEV = 1173.50
TEMPORARY
CHANNEL
PRIVATE TILE RE-LAY
0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 9+39.80
BP
: 0
+0 0.
EP
: 9
+3 9.
NORMAL POOL (1171.00)
DEEP WATER AREA (<1168.00)
100-YEAR HWL (1175.31)
PROPOSED EASEMENT BOUNDARY
EXCAVATE TO 1170.50
RIP-RAP
FLEXAMAT CONCRETE BLOCK MAT
STRUCTURE SEEDING
LEGEND
SHEET
B ol to n
M en k, In c.
5, A ll Ri gh ts
R es er ve d c h:
\h am ilt on
_c o_ ia \0 a1
\C
AD
\C 3D
\P et er so n\
D0 1.
dw g
1/
/2
:3 2:
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV HAMILTON COUNTY, IOWA
HAM892326B NUTRIENT REDUCTION WETLAND
BCS
NVD
JPR
0A1.127685
1.1 BID PLANS 01-22-2026
R
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.com
R
FEETSCALE
0 50 100
HORZ.
FEETSCALE
0 5 10
VERT. D.01
SEPARATION BERM PLAN & PROFILE
0+00 1+00 2+00
0.00%
BOTTOM OF 10-FT
CHANNEL = 1170.50
NWL = 1170.50
SEPARATION BERM
1173.50
FUTURE BORROW
POND BY OTHERS
EXCAVATED
POOL
.3
.9
.5
.5
.5
.2
.5
.8
.5
.7
.5
.4
.2
0+00 1+00 2+00
BP
: 0
+0 0.
EP
: 2
+0 0.
CONNECTION CHANNEL
10 FT BOTTOM WIDTH
3:1 SIDE SLOPES
FLEXAMAT CONCRETE BLOCK MAT
100' x 23.5'
SEED PRIOR TO PLACING FLEXAMAT
0+00
1+00
2+00
3+00
BP
: 0
+0 0.
PC
: 2
+1 7.
PT: 2+56.62
EP: 3+00.00
DIVERSION BERM
TOP ELEV = 1170.50
.5
.4
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
0+00 1+00 2+00 3+00
.0
0% 0.00%
TOP OF DIVERSION BERM = 1170.50
NWL = 1170.50
EXCAVATED POOL
NORMAL POOL (1171.00)
DEEP WATER AREA (<1168.00)
100-YEAR HWL (1175.31)
PROPOSED EASEMENT BOUNDARY
EXCAVATE TO 1170.50
RIP-RAP
FLEXAMAT CONCRETE BLOCK MAT
STRUCTURE SEEDING
LEGEND
SHEET
B ol to n
M en k, In c.
5, A ll Ri gh ts
R es er ve d c h:
\h am ilt on
_c o_ ia \0 a1
\C
AD
\C 3D
\P et er so n\
D0 1.
dw g
1/
/2
:3 2:
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV HAMILTON COUNTY, IOWA
HAM892326B NUTRIENT REDUCTION WETLAND
BCS
NVD
JPR
0A1.127685
1.1 BID PLANS 01-22-2026
R
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.com
R
FEETSCALE
0 50 100
HORZ.
FEETSCALE
0 5 10
VERT. D.02
CONNECTION CHANNEL & DIVERSION BERM
R
4:1 SIDE SLOPES EXCAVATED POOL
10' TOP WIDTH
DIVERSION BERM
CROSS SECTION
DIVERSION BERMCONNECTION CHANNEL
SEEDING AREAS
BUFFER SEEDING 2.5 AC
STRUCTURE SEEDING 0.4 AC
801185 11
117211
117711
841186 11
79 1179
82 1183 11841184
SEED BERM & CHANNEL
STRUCTURE SEEDING
SEED AREAS DISTURBED FOR PIPE INSTALLATIONS
BUFFER SEEDING
SEED DISTRUBED/GRADED AREAS TO
1 FT BELOW NORMAL POOL
BUFFER SEEDING
DO NOT SEED POOL OR DIVERSION BERM
SEED FINAL SPOIL AREA
BUFFER SEEDING
SEED COVER BERM
BUFFER SEEDING
SEED INLET CHANNEL TO 1 FT
BELOW NORMAL POOL
STRUCTURE SEEDING
SEED SEPARATION BERM AND
CONNECTION CHANNEL
STRUCTURE SEEDING
SEED PRIOR TO PLACING FLEXAMAT
PROPOSED EASEMENT BOUNDARY
RIP-RAP
BUFFER SEEDING (2.5 AC)
STRUCTURE SEEDING (0.4 AC)
LEGEND
SHEET
B ol to n
M en k, In c.
5, A ll Ri gh ts
R es er ve d c h:
\h am ilt on
_c o_ ia \0 a1
\C
AD
\C 3D
\P et er so n\
K0 1.
dw g
1/
/2
:3 2:
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV HAMILTON COUNTY, IOWA
HAM892326B NUTRIENT REDUCTION WETLAND
BCS
NVD
JPR
0A1.127685
1.1 BID PLANS 01-22-2026
R
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.com
K.01
SEEDING PLANFEETSCALE
0 100 200
HORZ.
0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00
.2
.9
.6
.1
.4
.2
.2
.3
.1
.1
.9
.4
.3
.2
.1
.0
.9
.8
.6
.5
-0.11%
STA: 0+45
EL: 1172.50 STA: 9+77
EL: 1171.50
WETLAND INLET CHANNEL
EXISTING GROUND SURFACE
NWL = 1170.50
COVER BERM
MIN. 3 FT COVER
EXISTING 12" CLAY TILE
ST
A
9+
" A
PR
O
N , F
O O
TI
N
G, B
AR
G
U
AR
D
FL
IN
1.
(1 5"
S W
ST
A
0+
CO
N
N
EC
T
TO
E
XI
ST
IN
G
" C
LA
Y
TI
LE
M
AT
CH
C
RO
W N
S
FL
IN
2.
(1 2"
S
FL
O
U T
.5
(1
5" N
E)
932' - 15" RCP
932 LF - 15" CLASS IV RCP 7745
BRANCH TILE RE-LAY
EXISTING BRANCH CAPACITY = 1.95 CFS
PROPOSED BRANCH RE-LAY CAPACITY = 2.14 CFS
0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00
BP
: 0
+0 0.
EP
: 1
0+
.0
STA 0+45
CONNECT TO EXISTING 12' CLAY TILE
MATCH CROWNS
STA 9+77
15" APRON, FOOTING, BAR GUARD
COVER BERM EXTENTS
GRADE OUT
AT 10:1 SLOPE
RIP RAP
4.8 TONS
RIP RAP
4.8 TONS
0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 10+50
.1
.0
.9
.9
.5
.1
.9
.8
.9
.7
.0
.6
.4
.3
.1
.0
.9
.8
.6
.5
-0.13%
STA: 0+45
EL: 1172.50 STA: 8+43
EL: 1171.50
ST
A
4+
° E
LB
O
W
FL
IN
2.
(1 2"
S
FL
O
U T
.0
(1
2" N
E)
ST
A
8+
" A
PR
O
N , F
O O
TI
N
G, B
AR
G
U
AR
D
FL
IN
1.
(1 2"
S W
ST
A
0+
CO
N
N
EC
T
TO
E
XI
ST
IN
G
" C
LA
Y
TI
LE
M
AT
CH
C
RO
W N
S
FL
IN
2.
(1 0"
S W
FL
O U
T
.5
(1 2"
N
WETLAND INLET CHANNEL
EXISTING GROUND SURFACE
NWL = 1170.50
COVER BERM
MIN. 3 FT COVER
EXISTING 10" CLAY TILE
798' - 12" RCP
798 LF - 12" CLASS IV RCP 4345
MAIN TILE RE-LAY
EXISTING MAIN CAPACITY = 1.25 CFS
PROPOSED MAIN RE-LAY CAPACITY = 1.28 CFS
0+00 1+00
2+00 3+00
4+00 5+00 6+00
7+00 8+00
9+00
10+00 10+50
BP
: 0
+0 0.
PI
: 4
+2 7.
PI
: 8
+7 5.
EP
: 1
0+
.0
STA 0+45
CONNECT TO EXISTING 10' CLAY MAIN
MATCH CROWNS
STA 4+27
27° ELBOW
STA 8+43
12" APRON, FOOTING, BAR GUARD
COVER BERM EXTENTS
GRADE OUT
AT 10:1 SLOPE
RIP RAP
3.6 TONS
MIN. 3 FT COVER OVER PIPE
10:1 SIDE SLOPES
OUTSIDE OF EASEMENT
BRANCH RE-LAY
MAIN RE-LAY
COVER BERM CROSS SECTION
EXISTING
GROUND SURFACE
NORMAL POOL (1171.00)
DEEP WATER AREA (<1168.00)
100-YEAR HWL (1175.31)
PROPOSED EASEMENT BOUNDARY
RIP-RAP
EXCAVATE TO 1170.50
FLEXAMAT CONCRETE BLOCK MAT
LEGEND
SHEET
B ol to n
M en k, In c.
5, A ll Ri gh ts
R es er ve d c h:
\h am ilt on
_c o_ ia \0 a1
\C
AD
\C 3D
\P et er so n\
M
.d w g 1/
/2
:3
2:
A M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV HAMILTON COUNTY, IOWA
HAM892326B NUTRIENT REDUCTION WETLAND
BCS
NVD
JPR
0A1.127685
1.1 BID PLANS 01-22-2026
R
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.com
FEETSCALE
0 100 200
HORZ.
FEETSCALE
0 5 10
VERT. M.01
PLAN AND PROFILE - TILE RELAYS
R
0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00 13+00 14+00 15+00 16+00 16+50
.6
.7
.2
.0
.1
.6
.5
.2
.6
.9
.5
.5
.9
.3
.2
.8
.9
.4
.3
.2
.0
.1
.0
.9
.8
.7
.6
.5
.4
.3
.2
.1
.0
PO
N
D
IN
LE
T
(S
TA
6+
M O
DI
FI
ED
S
W -5
SE
E B.
TO
P
.0
O
PE
N
IN
G
.0
FL
IN
7.
(1
5" N
SW
-4
(S
TA
+3 0)
SW
-4
(4
8i n)
SU
DA
S
SW
-6
T
YP
E G
CA
ST
IN
G
TO
P
.2
FL
IN
5.
(1 2"
N W
FL
O U
T
.5
(1 5"
S
FL
O
U T
.1
(1
2" S
E)
EXISTING 12" CLAY TILE
NWL = 1170.50
EXISTING GROUND SURFACE
EXCAVATED WETLAND POOL
ST
A
4+
GR
AD
E
BR
EA
K
FL
IN
8.
(1
5" N
FL
O U
T
.1
(1 5"
S
PARTIAL CAPTURE INLET
-0.10%
-2.20%
-0.10%
STA: 0+30
EL: 1173.50
STA: 2+55
EL: 1173.28
STA: 4+90
EL: 1168.12 STA: 16+10
EL: 1167.00
ST
A
2+
GR
AD
E
BR
EA
K
FL
IN
3.
(1
5" N
FL
O U
T
.2
(1 5"
S
1579' - 15" RCP
1579 LF - 15" SMOOTH LINED CPDT 0930
0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00 13+00 14+00 15+00 16+0016+18.76>> >> >> >> >> >> >> >> >> >> >> >> >> >>
BP: 0+00.00
PI: 0+30.00 PI
: 2 +5
5.
PI
: 4
+9 0.
EP
: 1
6+
.7
STA 16+10
MODIFIED SW-513 (SEE B.03)
STA 0+30
SW-401 (48IN)
RIP RAP
2.9 TONS
ST
A
2+
° E
LB
O
W
FL
IN
3.
(1 2"
N W
FL
O U
T
.5
(1 2"
S E)
NWL = 1170.50
0+00 1+00 2+00 3+00 4+00 5+00 6+00
-0.66%
STA: 0+30
EL: 1175.08
STA: 5+76
EL: 1171.50
SW
-4
(S
TA
+3 0)
SW
-4
(4
8i n)
SU
DA
S
SW
-6
T
YP
E G
CA
ST
IN
G
TO
P
.2
FL
IN
5.
(1 2"
N W
FL
O U
T
.5
(1 5"
S
FL
O
U T
.1
(1
2" S
E)
ST
A
5+
" A
PR
O
N , F
O O
TI
N
G, B
AR
G
U
AR
D
FL
IN
1.
(1 2"
N W
.6
.9
.3
.6
.0
EXISTING GROUND SURFACE
EXCAVATED BORROW POOL
EXISTING 12" CLAY TILE
546' - 12" RCP
546 LF - 12" CLASS IV RCP 7630
PRIVATE TILE RE-LAY
EXISTING PRIVATE TILE CAPACITY = 2.58 CFS
PROPOSED PRIVATE TILE RE-LAY CAPACITY = 2.89 CFS
.6
.6
.4
.7
.1
.3
.4
0+00 1+00
2+00 3+00
4+00 5+00
6+00
BP
: 0
+0 0.
PI
: 0
+3 0.
00 PI
: 2
+7 3.
PI
: 5
+7 6.
EP
: 6 +0
0.
STA 0+30
SW-401 (48IN)
STA 5+76
12" APRON, FOOTING, BAR GUARD
RIP RAP
3.6 TONS
NORMAL POOL (1171.00)
DEEP WATER AREA (<1168.00)
100-YEAR HWL (1175.31)
PROPOSED EASEMENT BOUNDARY
RIP-RAP
EXCAVATE TO 1170.50
FLEXAMAT CONCRETE BLOCK MAT
LEGEND
SHEET
B ol to n
M en k, In c.
5, A ll Ri gh ts
R es er ve d c h:
\h am ilt on
_c o_ ia \0 a1
\C
AD
\C 3D
\P et er so n\
M
.d w g 1/
/2
:3
2:
A M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV HAMILTON COUNTY, IOWA
HAM892326B NUTRIENT REDUCTION WETLAND
BCS
NVD
JPR
0A1.127685
1.1 BID PLANS 01-22-2026
R
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.com
R
FEETSCALE
0 100 200
HORZ.
FEETSCALE
0 5 10
VERT. M.02
PARTIAL CAPTURE INLET & PRIVATE TILE RE-LAY
0+00 1+00 2+00 3+00 4+00
EXISTING GROUND SURFACE
NWL = 1170.50
-0.50%
STA: 0+05
EL: 1166.84
STA: 3+75
EL: 1165.00
PO
N
D O
U
TL
ET
(S
TA
+0 5)
M O
DI
FI
ED
S
W -5
SE
E B.
TO
P
.5
O
PE
N
IN
G
.5
FL
O
U T
.8
(1
8" N
E)
ST
A
3+
CO
N
N
EC
T
TO
E
XI
ST
IN
G
" C
LA
Y
TI
LE
M
AT
CH
F
LO
W
LI
N
ES
FL
IN
5.
(1
8" S
W
FL
O
U T
.0
(1
5" E
EXCAVATED WETLAND POOL EXISTING 18" CLAY TILE
369' - 18" RCP
369 LF - 18" CLASS IV RCP 7506
WETLAND OUTLET
EXISTING TILE CAPACITY = 1.75 CFS
PROPOSED OUTLET CAPACITY = 7.43 CFS
0+00 1+00
2+00
3+00 4+00BP
: 0 +0
0.
00 PI
: 3 +7
5.
0+00 1+00
2+00
3+00 4+00BP
: 0 +0
0.
00 PI
: 3 +7
5.
STA 0+05
MODIFIED SW-513
(SEE B.03)
STA 3+75
CONNECT TO EXISTING 18" CLAY TILE
MATCH FLOWLINES
RIP RAP
0.6 TONS
NORMAL POOL (1171.00)
100-YEAR HWL (1175.31)
PROPOSED EASEMENT BOUNDARY
EXCAVATE TO 1170.50
LEGEND
SHEET
B ol to n
M en k, In c.
5, A ll Ri gh ts
R es er ve d c h:
\h am ilt on
_c o_ ia \0 a1
\C
AD
\C 3D
\P et er so n\
M
.d w g 1/
/2
:3
2:
A M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV HAMILTON COUNTY, IOWA
HAM892326B NUTRIENT REDUCTION WETLAND
BCS
NVD
JPR
0A1.127685
1.1 BID PLANS 01-22-2026
R
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.com
R
FEETSCALE
0 25 50
HORZ.
FEETSCALE
0 5 10
VERT. M.03
WETLAND OUTLET
| 2026-01-22T10:34:30-0600 | |
| Brandon Short |
File details come from the government source that posted it. Updated .