This solicitation is for renovation services at Building 15 at the Veterans Health Administration facility in Marion, Illinois. Key requirements include fully sprinklering the building, installing new HVAC, plumbing and electrical systems. Drawings and specifications are provided detailing the scope of work. The contract will be awarded on a firm-fixed price basis. The period of performance is 270 days. The solicitation was issued by the Department of Veterans Affairs and responses are due within 30 days.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SB
SS
0 HZ
0 SB
FIRE PROTECTION SYMBOL LIST
SYMBOL: DESCRIPTION:
FIRE PROTECTIONFP
FIRE PROTECTION - DRY SYSTEMFPD
SERVICE WATER - POTABLEW
AIR PRESSURE MAINTENANCE DEVICE
AIR SUPERVISORY SWITCH
ANGLE VALVE
BUTTERFLY VALVE WITH MONITOR SWITCH
OS&Y GATE VALVE
OS&Y GATE VALVE WITH MONITOR SWITCH
PRESSURE SWITCH
P
NO HATCH
ORDINARY HAZARD GROUP I COVERAGE AREA: 0.15 GPM/sq.ft OVER
A REMOTE OPERATING AREA OF 1500 SQUARE FEET AND
COMBINED HOSE ALLOWANCE OF 250 GPM.
EXTRA GROUP 1
EXTRA GROUP 2
SPRINKLER - WALL MOUNTED
SPRINKLER
SPRINKLER - CONCEALED
SPRINKLER
SPRINKLER
SPRINKLER
SPRINKLER
A
SPRINKLER
A
INSPECTOR TEST AND DRAIN VALVE
MONITOR SWITCH
COMPRESSED AIR - FIRE PROTECTIONCAF
PIPE CAP
PIPE DOWN
NEW CONNECTION
PIPE UP OR UP/DOWN
SHUTOFF VALVE NORMALLY OPEN
DEMOLITION
DRAINDFP
NOT ALL SYMBOLS MAY APPLY.
AUTOMATIC DRAIN VALVE
UNION/FLANGE
DIRECTION OF FLOW IN PIPE
PRESSURE GAUGE (FURNISHED WITH BALL VALVE)P
CHECK VALVE
FLOW SWITCH
F
ROUTE TO DRAIN
AREA BOUNDARY
LIGHT HAZARD COVERAGE AREA: 0.10 GPM/sq.ft. OVER A REMOTE
OPERATING AREA OF 1500 SQUARE FEET COMBINED HOSE
ALLOWANCE OF 100 GPM.
ORDINARY HAZARD GROUP II COVERAGE AREA: 0.20 GPM/sq.ft
OVER A REMOTE OPERATING AREA OF 1500 SQUARE FEET AND
COMBINED HOSE ALLOWANCE OF 250 GPM.
FIRE PROTECTION ABBREVIATION KEY
AD ACCESS DOOR
BFP BACKFLOW PREVENTER
N.C. NORMALLY CLOSED
ABOVE FINISHED FLOORAFF
NC NEW CONNECTION
NOT IN CONTRACTNIC
NORMALLY OPENN.O.
ABBR: DESCRIPTION:
TYPICALTYP
UNLESS NOTED OTHERWISEUNO
I.E. INVERT ELEVATION
PLAN OR DETAIL NUMBER
PLAN OR DETAIL NAME
PLAN OR DETAIL SCALE
DETAIL REFERRED TO BY SECTION CUT
SHEET DETAIL IS LOCATED ON
NAME
VIEW NAME
1/8" = 1'-0"
M101
T101
SIM
DETAIL REFERRED TO BY ELEVATION
SHEET DETAIL IS LOCATED ON
INDICATES SIMILAR DETAIL
REFERENCED IN MULTIPLE LOCATIONS
SIM
INDICATES SIMILAR DETAIL
REFERENCED IN MULTIPLE LOCATIONS
LEVEL NAME
10' - 0" HEIGHT ABOVE
PROJECT 0' - 0"
1 INDICATES NOTE USED TO DESCRIBE
ADDITIONAL INFORMATION ABOUT
WORK REQUIRED, SPECIFIC TO THE
SHEET AND/OR DETAIL
N
O R HT
INDICATES DIRECTION OF TRUE NORTH
VIEW KEY
NEW WORK BY THIS CONTRACTOR
(DARK SOLID LINE)
NEW WORK UNDERFLOOR OR UNDERGROUND BY THIS CONTRACTOR
(DARK LONG DASHED LINE)
EXISTING TO REMAIN
(LIGHT SOLID LINE)
EXISTING TO BE REMOVED BY THIS CONTRACTOR
(DARK SHORT DASHED LINE)
LINE TYPE KEY:
NEW PARTITION KEY WALL RATING DESCRIPTION
2 HR
BUILDING SEPARATION:
FIRE BARRIER
1 HR
OCCUPANCY / AREA SEPARATION:
FIRE BARRIER
2 HR
OCCUPANCY / AREA SEPARATION:
FIRE BARRIER
2 HR
1 HR
VERT. OPG. (EXIT ENCLSR/SHAFT)
FIRE BARRIER
(2 HR = 4 OR MORE STORIES)
(1 HR = LESS THAN 4 STORIES)
2 HR
1 HR
EXIT PASSAGEWAY (HORIZ)
FIRE BARRIER
1 HR
HAZ / INCIDENTAL USE
FIRE BARRIER
NR-
RESIST
SMK
HAZ / INCIDENTAL USE
SMOKE PARTITIONS (SPRINKLERED)
1 HR
1/2 HR
SUBDIVIDING SPACES
SMOKE BARRIER
NR
SUITE SEPARATION
SMOKE PARTITIONS
HORIZONTAL BUILDING SEPARATION
FIRE BARRIER
2 HR
FIRE/SMOKE BARRIER DESIGNATIONS
THE LINE TYPES SHOWN ARE FOR THE CONVENIENCE OF THE CONTRACTOR. THE CONTRACTOR' SHALL VERIFY RATINGS WITH THE LATEST SET OF ARCHITECTURAL PLANS AND FURNISH ALL MATERIALS REQUIRED TO COMPLY WITH THOSE RATINGS
WHETHER SHOWN OR NOT.
RATINGS WERE ACQUIRED FROM THE ARCHITECTURAL PLANS DATED 03/28/2019
TEMPERATURE CONTROLS CONTRACTORT.C.C.
CIVIL CONTRACTORC.C.
FIRE PROTECTION CONTRACTORF.P.C.
PLUMBING CONTRACTORP.C.
GENERAL CONTRACTORG.C.
MECHANICAL CONTRACTORM.C.
ELECTRICAL CONTRACTORE.C.
CONTRACTOR ABBREVIATION KEY
ABBR: DESCRIPTION:
MECHANICAL RENOVATION NOTES:
THESE NOTES APPLY TO ALL MECHANICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED
TO FIRE PROTECTION, PLUMBING, VENTILATION, PIPING AND TEMPERATURE CONTROL.
1. EXISTING CONDITIONS ARE SHOWN BASED ON INFORMATION OBTAINED FROM FIELD
SURVEYS, EXISTING BUILDING DOCUMENTS, AND STAFF. CONTRACTOR SHALL VERIFY
EXISTING CONDITIONS PRIOR TO BIDDING AND REPORT ANY CONFLICTS BEFORE
PROCEEDING.
2. NOT ALL EXISTING DUCTWORK AND PIPING IS SHOWN. VERIFY EXISTING CONDITIONS
BEFORE STARTING WORK. VERIFY EXISTING DUCT AND PIPING CONDITIONS PRIOR TO
BIDDING. NOTIFY ENGINEER OF ANY CONFLICTS WITH NEW WORK.
3. FIELD VERIFY THE AVAILABLE CLEARANCES FOR PIPING BEFORE FABRICATION. RISES AND
DROPS MAY BE NECESSARY BECAUSE OF EXISTING FIELD CONDITIONS.
4. EACH CONTRACTOR SHALL FIELD VERIFY ACCESSIBILITY TO THE AREA OF HIS/HER WORK
AND SHALL NOTIFY THE GENERAL CONTRACTOR PRIOR TO BIDDING IF OTHER UTILITIES ARE
REQUIRED TO BE REMOVED OR RELOCATED TO ALLOW ACCESS TO HIS/HER AREA OF
WORK.
5. EACH CONTRACTOR SHALL CUT AND PATCH WALLS ASSOCIATED WITH HIS WORK.
6. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND REPLACEMENT OF
CEILINGS, CEILING TILES, AND CEILING GRIDS ASSOCIATED WITH AREAS OF WORK BY ALL
CONTRACTORS. NOTIFY THE GENERAL CONTRACTOR OF AFFECTED AREAS PRIOR TO
BIDDING.
7. WHERE EXISTING MECHANICAL SYSTEMS ARE LOCATED IN AREAS THAT CONFLICT WITH
NEW EQUIPMENT, PIPING, OR DUCTWORK TO BE INSTALLED, EACH CONTRACTOR SHALL
EITHER ARRANGE NEW EQUIPMENT, PIPING, OR DUCTWORK IN SUCH A FASHION THAT IT
DOES NOT CONFLICT WITH EXISTING SYSTEMS, OR REWORK EXISTING MECHANICAL
SYSTEMS TO ALLOW FOR INSTALLATION OF NEW EQUIPMENT, PIPING, OR DUCTWORK.
8. PROVIDE TEMPORARY CONNECTIONS TO MAINTAIN EXISTING SYSTEMS IN SERVICE DURING
CONSTRUCTION. MAINTAIN ACCESS TO EXISTING MECHANICAL INSTALLATIONS THAT
REMAIN ACTIVE.
9. OBTAIN PERMISSION FROM OWNER BEFORE SHUTTING DOWN ANY SYSTEM FOR ANY
REASON. ALL SYSTEM SHUTDOWNS WILL REQUIRE 3 WEEKS NOTICE PRIOR TO THE
SHUTDOWN EVENT. MAINTAIN SERVICE TO ALL COMPONENTS THAT ARE TO REMAIN UNTIL
NEW SYSTEMS ARE INSTALLED.
10. MAINTAIN EXISTING SYSTEM IN SERVICE UNTIL NEW SYSTEM IS COMPLETE AND READY FOR
TIE IN AND SWITCHOVER. DRAIN SYSTEM ONLY TO MAKE SWITCHOVERS AND
CONNECTIONS. OBTAIN PERMISSION FROM OWNER BEFORE PARTIALLY OR COMPLETELY
DRAINING SYSTEM. MAKE CHANGEOVER TO NEW SYSTEMS WITH MINIMUM OUTAGE.
11. DISCONNECT AND REMOVE MECHANICAL DEVICES AND EQUIPMENT SERVING EQUIPMENT
THAT HAS BEEN REMOVED.
1. THE SYMBOLS AND THE MATERIAL LIST ARE FOR THE CONVENIENCE OF THE CONTRACTOR.
CONTRACTOR SHALL VERIFY QUANTITIES AND FURNISH ALL MATERIALS REQUIRED FOR
FULLY OPERATIONAL SYSTEMS, WHETHER SPECIFIED OR NOT. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO RETAIN A LICENSED FIRE PROTECTION ENGINEER AND CONTRACTOR,
AS REQUIRED, TO COMPLETE THE FIRE PROTECTION PLAN. THE PLAN SHALL CONFORM TO
ALL APPLICABLE REQUIREMENTS OF THE NFPA, IFC AND ANY OTHER AUTHORITIES HAVING
JURISDICTION. THE PLAN SHALL BE SUPPLIED TO ALL REQUIRED AUTHORITIES FOR REVIEW
AND APPROVAL PRIOR TO ANY WORK.
2. FIRE PROTECTION PIPE ROUTING IS SHOWN FOR GENERAL LAYOUT. DETERMINE EXACT
NUMBER OF SPRINKLERS, PIPE SIZING, AND PIPE ROUTING.
3. CATALOG NUMBERS SHALL NOT BE CONSIDERED COMPLETE, BUT ARE GIVEN AS AN AID TO
THE CONTRACTOR AND TO INDICATE THE QUALITY REQUIRED. CONTRACTOR IS
RESPONSIBLE FOR A COMPLETE DESCRIPTION OF MATERIAL ON THESE DRAWINGS AND IN
THE SPECIFICATIONS BEFORE ORDERING. THE DESCRIPTION OF THE MATERIAL TAKES
PRECEDENCE OVER THE CATALOG NUMBER. THE FIRST MANUFACTURER IS THE BASIS OF
DESIGN.
4. CENTER SPRINKLERS IN CEILING TILES IN BOTH DIRECTIONS IN ALL AREAS. IN AREAS WITH
2’X4’ CEILING TILES CENTERING USING A 2’X2’ CEILING PATTERN IS ACCEPTABLE.
5. NEW SPRINKLERS SHALL BE QUICK RESPONSE TYPE, UNLESS OTHERWISE NOTED.
CONTRACTOR SHALL NOT MIX STANDARD RESPONSE SPRINKLERS WITH QUICK RESPONSE
SPRINKLERS IN UNPARTITIONED SPACES.
6. PROVIDE COVERAGE ABOVE AND BELOW FLOATING CEILINGS, REFER TO ARCHITECTURAL
PLANS.
FIRE PROTECTION GENERAL NOTES:
MECHANICAL GENERAL NOTES:
THESE NOTES APPLY TO ALL MECHANICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED
TO, FIRE PROTECTION, PLUMBING, VENTILATION, PIPING AND TEMPERATURE CONTROL.
1. DRAWINGS SHOWING LOCATIONS OF EQUIPMENT, DUCTWORK, PIPING, ETC. ARE
DIAGRAMMATIC AND MAY NOT ALWAYS REFLECT EXACT INSTALLATION CONDITIONS.
DRAWINGS SHOW THE GENERAL ARRANGEMENT OF DUCTWORK, PIPING, EQUIPMENT, ETC.,
AND MAY NOT INCLUDE ALL OFFSETS AND FITTINGS REQUIRED FOR COMPLETE
INSTALLATION. THE DRAWINGS SHALL BE FOLLOWED AS CLOSELY AS ACTUAL BUILDING
CONSTRUCTION AND THE WORK OF OTHERS WILL PERMIT.
2. DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS AND CLEARANCES FROM
ARCHITECTURAL, STRUCTURAL, SUBMITTALS, AND OTHER APPROPRIATE DRAWINGS OR
PHYSICALLY AT SITE. REVIEW ALL DRAWINGS, INCLUDING THOSE OF OTHER TRADES.
3. COORDINATE ALL WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION TO PROVIDE
CLEARANCES REQUIRED FOR OPERATION, MAINTENANCE, CODE COMPLIANCE, AND TO
VERIFY NON-INTERFERENCE WITH OTHER WORK. DO NOT FABRICATE PRIOR TO
VERIFICATION OF NECESSARY CLEARANCES FOR ALL TRADES. BRING ANY INTERFERENCES
OR CONFLICTS TO THE ATTENTION OF THE ARCHITECT/ENGINEER BEFORE PROCEEDING
WITH FABRICATION OR EQUIPMENT ORDERS.
4. REVIEW SPACE REQUIREMENTS OF EQUIPMENT SPECIFIED OR SUBSTITUTED AND MAKE
REASONABLE ACCOMMODATIONS IN LAYOUT AND POSITIONING TO PROVIDE PROPER
ACCESS.
5. ANY CHANGES REQUIRED TO ELIMINATE CONFLICTS OR THAT RESULT FROM A FAILURE TO
COORDINATE SHALL BE MADE BY THE CONTRACTOR WITHOUT ADDITIONAL COST OR
EXPENSE TO OTHERS.
6. EACH CONTRACTOR IS RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH ELECTRICAL
CHANGES REQUIRED FOR EQUIPMENT PROPOSED THAT DIFFERS FROM THE BASIS OF
DESIGN.
7. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN, ELECTRICAL, TECHNOLOGY
AUDIO/VISUAL, AND OTHER MECHANICAL PLANS FOR EXACT LOCATIONS OF ALL CEILING
MOUNTED DEVICES, OTHER THAN SPRINKLERS.
8. EACH CONTRACTOR IS RESPONSIBLE FOR DAMAGE CAUSED BY THEIR ACTIONS TO WALLS,
FLOORS, CEILINGS, AND ROOFS. THE CONTRACTOR WHOSE WORK CAUSES DAMAGE IS
RESPONSIBLE FOR PATCHING TO MATCH ORIGINAL CONSTRUCTION, FIRE RATING, AND
FINISH.
9. IN AREAS WITH DRYWALL CEILINGS COORDINATE LOCATIONS OF ACCESS PANELS WITH THE
GC FOR ACCESS TO VALVES, DUCTWORK ACCESSORIES, DAMPERS, ETC. COORDINATE
PANEL TYPE AND COLOR WITH ARCHITECT. NOTIFY THE GC OF THE REQUIRED ACCESS
PANELS PRIOR TO BIDDING.
10. SEAL ALL WALL PENETRATIONS AIRTIGHT WHERE PIPING PENETRATE. PENETRATIONS
THROUGH EXTERIOR WALLS SHALL BE SEALED AIRTIGHT WITH WATERPROOFING
MATERIALS RECOMMENDED BY MANUFACTURER FOR OUTDOOR USE.
11. CAULK ALL PIPE PENETRATIONS OF FULL HEIGHT NON-FIRE RATED WALL AND PARTITION
ASSEMBLIES. THIS IS ESSENTIAL TO PREVENT NOISE TRANSMISSION FROM ONE ROOM TO
ANOTHER AND TO PROVIDE THE DESIRED NC LEVELS WITHIN ROOMS.
12. EQUIPMENT SIZES AND SERVICE CLEARANCE REQUIREMENTS VARY AMONG DIFFERENT
MANUFACTURERS. CONSULT APPROVED SHOP DRAWINGS FOR EQUIPMENT SIZES AND
REQUIRED SERVICE CLEARANCES. COORDINATE WITH LAYOUT OF EQUIPMENT PADS,
PIPING, DUCTWORK, ETC.
13. DO NOT BLOCK TUBE PULL OR EQUIPMENT SERVICE CLEARANCES.
14. MAINTAIN MINIMUM 3'-6” CLEARANCE IN FRONT OF ALL ELECTRICAL PANELS, MOTOR
STARTERS, SWITCHES, AND DISCONNECTS.
15. DO NOT SUPPORT EQUIPMENT OR PIPING FROM METAL DECKING OR OTHER NON-
STRUCTURAL BUILDING ELEMENTS. ANCHORS EMBEDDED IN CONCRETE SHALL BE
CRACKED CONCRETE APPROVED IN ACCORDANCE WITH SPECIFICATIONS.
16. INSTALL PIPING AND DUCTWORK A MINIMUM OF 2" ABOVE CEILING TO ALLOW FOR CEILING
PANEL REMOVAL/INSTALLATION.
17. INSTALL ITEMS REQUIRING ACCESS SUCH AS EQUIPMENT, DAMPERS OR VALVES AT A
HEIGHT NO GREATER THAN WHAT CAN BE ACCESSED FROM A 10-FOOT TALL STEPLADDER.
MECHANICAL PHASING NOTES:
THESE NOTES APPLY TO ALL MECHANICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED
TO, FIRE PROTECTION, PLUMBING, VENTILATION, PIPING AND TEMPERATURE CONTROL.
1. REFER TO ARCHITECTURAL DRAWINGS FOR GENERAL DESCRIPTION OF PHASES. REFER TO
ARCHITECT'S INSTRUCTIONS FOR MORE DETAILS, PHASING SCHEDULES AND FOR
CONCURRENT WORK. MECHANICAL, ELECTRICAL AND TECHNOLOGY DRAWINGS DEPICT
THE INTENT OF THE FINAL DESIGN. THE MECHANICAL, ELECTRICAL, AND TECHNOLOGY
DRAWINGS DO NOT DEPICT THE MEANS AND METHODS TO MEET THE REQUIREMENTS OF
THE PHASING CRITERIA.
2. REVIEW PROJECT PHASING PLANS TO COORDINATE DEMOLITION WORK, OUTAGES, ETC.
WITH AFFECTED ADJACENT AREAS.
3. PROVIDE AND INSTALL TEMPORARY DUCTWORK, PIPING, SHUTOFF VALVES, ETC. AS
NECESSARY TO KEEP ALL OCCUPIED SPACES OPERATIONAL THROUGHOUT ALL PHASES OF
THE PROJECT.
4. PHASE DEMOLITION WORK TO MINIMIZE DOWNTIME.
DEDUCT ALTERNATE NOTES:
THESE NOTES APPLY TO ALL MECHANICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED
TO FIRE PROTECTION, PLUMBING, VENTILATION, PIPING, AND TEMPERATURE CONTROL.
1. REFER TO ARCHITECTURAL PLANS AND SPECIFICATIONS FOR DEDUCT ALTERNATE INFORMATION.
CK-16
4" FP
AUTOMATIC DRAIN VALVE
GRADE
45° ELBOW
FIRE DEPARTMENT
CONNECTION, FDC-1
4" W
EXISTING 4"FP LINE IN
TUNNEL. CONNECT TO
EXISTING PIPING WITHIN
TUNNEL LOCATED IN
BUILDING 15.
BF-1
NC
P P
SYSTEM MAIN
DRAIN VALVE
AV-1
MS-1
MS-1
2" D
IT-1
BF-1 P
F
FS-1
TO FLOOR
SPRINKLERS
WATER
ENTRY
# KEYNOTES
1. ROUTE DISCHARGE TO EXTERIOR OF BUILDING. CAN
CONNECT TO COMBINED DRAIN LINE.
2. PROVIDE CONCRETE SPLASHBLOCK AT GRADE.
3. SEAL WALL PENETRATION WATERTIGHT.(TYPICAL)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID SET
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMP
321 4 5 6 7 8 9 10
ARCHITECT/ENGINEER OF RECORD
Calvin rchitects, P.C.L 3705 North 200th Street
Elkhorn, Nebraska 68022
Phone: 402.291.6941 POC:
AH. INZ
6910 Pacific St #310
Omaha, NE 68106
Phone: 402.553.0234 POC:
IMEG Corp.
2882 106th Street
Des Moines, Iowa
Phone: 515.334.4303
POC:
AMI Enviromental
8802 S 135th Street
Omaha, NE 68138
Phone: 402.397.5001
POC:
BID SET 07/17/2019
Dwg. of 73
C R e v it L o c a l F ile s \M
E P
T
.0
V A
M a ri o n
B
R e n o
C a a ro n
.c .m e y e r.
rv t
/1
/2
:0
:2
A
M
15-FP001
FIRE PROTECTION COVER SHEET RENOVATE BUILDING 15
VAHCS MARION, IL
657A5-18-111
07/17/2019 IMEG IMEG
NOTES:
1. SEE FLOOR PLANS FOR ZONING REQUIREMENTS.
2. SPRINKLER SHALL HAVE COLOR CODED BULB THERMAL ELEMENT.
3. ALL SPRINKLERS SHALL BE UL AND FM LISTED.
4. CONTRACTOR TO VERIFY SPRINKLER REQUIREMENTS BASED ON ACTUAL INSTALLATION, USAGE, ARCHITECTURAL CEILING
PLAN AND NFPA 13 REQUIREMENTS.
5. TAG NAME IS PRIMARILY FOR IDENTIFIYING SPRINKLERS IN SUBMITTALS. IT MAY OR MAY NOT BE FOUND ELSEWHERE ON
THE DRAWINGS. CONTRACTOR TO SUBMIT ALL SPRINKLER TYPES TO BE USED.
6. AREAS ARE GENERAL IN NATURE. CONTRACTOR TO MATCH UNSCHEDULED AREAS TO SIMILAR SPACES.
7. SPRINKLERS SPECIFIED WITHIN FIRE SPRINKLER USAGE SCHEDULE ARE STANDARD COVERAGE TYPE. EXTENDED COVERAGE
SPRINKLERS ARE PERMITTED PROVIDED SPRINKLERS MEET THE REQUIREMENTS OF UL AND FM.
FIRE SPRINKLER USAGE SCHEDULE
AREA TYPE
(NOTE 1 & 6)
AREA
HAZARD
SPRINKLER
TEMPERATURE
RATING
MANUFACTURER
& MODEL NOTES
TAG NAME
(NOTE 4 & 5)
SPRINKLER
TYPE
RESPONSE
CATEGORY FINISH
ROOMS WITH
CEILINGS
SEE PLANS SPR-1 RECESSED
PENDENT
QUICK CHROME 155 VIKING VK,
RELIABLE F1FR,
TYCO TY-FRB,
VICTAULIC V2708
NOTE 2, 3, 7
ROOMS WITH
OUT CEILINGS
SEE PLANS SPR-2 UPRIGHT QUICK ROUGH
BRASS
155 VIKING VK,
RELIABLE F1FR,
TYCO TY-FRB,
VICTAULIC V2704
NOTE 2, 3, 7
NO SCALE1
FIRE PROTECTION RISER DIAGRAM
Revisions: Date:
M & O
SUPERV.
OI+T
TOILET
PLUMBING SHOP
PROJECTS
SECTION
FILE
STORAGE
ELECTRIC
VAULT
MEN TOILET
TOILET
CHIEF ENGR.
WOMEN TOILET
ENGINEERING
CLERKS
MISC STORAGE
FACILITY
PLANNER
PROJECT
SUPERVISOR
ENERGY
MANAGER
CONFERENCE /
BREAKROOM
ASSIST
CHIEF
SHOWER
HAC
111A
105 105A
102A
109A 107A
104A
M & O
SUPERV.
OI+T
TOILET
PLUMBING SHOP
PROJECTS
SECTION
FILE
STORAGE
ELECTRIC
VAULT
MEN TOILET
TOILET
CHIEF ENGR.
WOMEN TOILET
ENGINEERING
CLERKS
MISC STORAGE
FACILITY
PLANNER
PROJECT
SUPERVISOR
ENERGY
MANAGER
CONFERENCE /
BREAKROOM
ASSIST
CHIEF
SHOWER
HAC
111A
105 105A
102A
109A 107A
104A
A
1 2
B
SPR-E
SPR-E
SPR-E
SPR-E
SPR-E
SPR-E
SPR-E
SPR-E
SPR-E
SPR-E
SPR-E
SPR-E
SPR-E
SPR-E
SPR-E
SPR-E
SPR-E
SPR-E
SPR-E
SPR-E SPR-E
SPR-E
SPR-E
SPR-E
SPR-E
FP FP
F P
FP
F P
4"FP
F P
F P
REMOVE FIRE DEPARTMENT
CONNECTION AND PIPING AS
INDICATED AND PREPARE
FOR NEW CONNECTION.
FDC-E
REMOVE FIRE PROTECTION
PIPING DOWN INTO STEAM
TUNNEL AND PREPARE FOR
NEW CONNECTION.
REMOVE EXISTING HOSE
VALVE AND CABINET. REFER
TO ARCHITECTURAL FOR NEW
FIRE EXTINGUISHER CABINET.
REMOVE ALL SPRINKLER PIPING, SPRINKLER
HEADS, AND ALL BRACKETS, HANGERS,
ACCESSORIES, ETC. PIPING SHALL BE REMOVED
BACK TO MAIN IN STEAM TUNNEL CLOSET AND
PREPARE FOR NEW CONNECTION.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID SET
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMP
321 4 5 6 7 8 9 10
ARCHITECT/ENGINEER OF RECORD
Calvin rchitects, P.C.L 3705 North 200th Street
Elkhorn, Nebraska 68022
Phone: 402.291.6941 POC:
AH. INZ
6910 Pacific St #310
Omaha, NE 68106
Phone: 402.553.0234 POC:
IMEG Corp.
2882 106th Street
Des Moines, Iowa
Phone: 515.334.4303
POC:
AMI Enviromental
8802 S 135th Street
Omaha, NE 68138
Phone: 402.397.5001
POC:
BID SET 07/17/2019
Dwg. of 73
C R e v it L o c a l F ile s \M
E P
T
.0
V A
M a ri o n
B
R e n o
C a a ro n
.c .m e y e r.
rv t
/1
/2
:0
:2
A
M
15-FD101
FIRST FLOOR PLAN - FIRE
PROTECTION DEMOLITION
RENOVATE BUILDING 15
VAHCS MARION, IL
657A5-18-111
07/17/2019 IMEG IMEG
N
O R HT
1/4" = 1'-0"1
FLOOR PLAN - FIRE PROTECTION DEMOLITION
GENERAL SHEET NOTES:
1. REFER TO 15-FP-001 FOR MORE INFORMATION.
Revisions: Date:
TOILETWOMEN TOILET HAC
102A104 104A
TOILETWOMEN TOILET HAC
102A104 104A
0 SB 0 SB0 SB 0 SB 0 SB
S
B S
B S
B S
B S
B S
B
S
B S
B S
B S
B S
B S
B
SS SSSS SS SS
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
A
1 2
99 SF
PROJECT
ENGINEER
SUPERVISOR
100 SF/
Not Enclosed
PLAN ROOM
200 SF/
203 SF
BREAK ROOM
319 SF
CONFERENCE
ROOM
300 SF/
41 SF
UNISEX STAFF
TLT
60 SF/
70 SF
UNISEX STAFF
TLT
80 SF/
102 SF
OI&T ROOM
101D
100 SF/
46 SF
HAC
60 SF/
27 SF
ALCOVE
101B
196 SF
MECHANICAL
101C
488 SF/
61 SF
STORAGE
60 SF/ 102 SF
ASST. CHIEF
ENGINEER
100 SF/ 102 SF
CHIEF ENGINEER
100 SF/ 100 SF
FACILITY
PLANNER
100 SF/ 96 SF
ENERGY
MANAGER
100 SF/
60 SF
MENS TOILET
60 SF/ 59 SF
WOMENS TOILET
60 SF/ 99 SF
M&O
SUPERVISOR
100 SF/
14 SF
CLOSET
96 SF
M&O
SUPERVISOR
100 SF/ 105 SF
M&O
SUPERVISOR
100 SF/ 103 SF
M&O
SUPERVISOR
100 SF/
154 SF
CORRIDOR
C01
56 SF
ADMIN OFFICE
ASST
56 SF/
117 SF
CORRIDOR
C01A
128 SF
CORRIDOR
C01B
196 SF
ELECTRICAL
105A
488 SF/
124 SF
CORRIDOR
C02
63 SF
VESTIBULE
Not Enclosed
STEAM TUNNEL
Not Enclosed
PROJECT
ENGINEERS
WORKSTATIONS
121A
116 SF
PROJECT
ENGINEERS
EGRESS
121B
9 SF
SHOWER
118A
32 SF
CORRIDOR
C01C
16 SF
STORAGE
C01D
B
172 SF
ENG.
CLERK/TRANS.MGR
101A
173 SF
LOBBY
496 SF
PROJECT
ENGINEERS
WORKSTATIONS
56 SF/
PROVIDE NEW PIPING AND SPRINKLER HEADS
FOR REVISED FLOOR PLAN. COORDINATE
ROUTING AND ELEVATION WITH NEW MEP AND
CEILING HEIGHT/LAYOUT.
PROVIDE NEW FIRE
DEPARTMENT CONNECTION.
SEAL BUILDING PENETRATION
WATERTIGHT WITH LINK SEAL.
PROVIDE DOUBLE CHECK
BACKFLOW PREVENTER IN
VERTICAL
PROVIDE RISER MAIN DRAIN AND PIPE TO
EXTERIOR. PROVIDE SPLASH BLOCK IF
TERMINATION POINT IS NOT OVER CONCRETE
ROUTE INSPECTOR TEST
DRAIN ALONG WALL AND TIE
INTO RISER DRAIN LINE PRIOR
TO EXTERIOR WALL
PENETRATION.
INSPECTOR TEST AND DRAIN
CHECK VALVE
BUTTERFLY VALVE WITH
MONITOR SWITCH
FLOW SWITCH
4"FP
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID SET
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMP
321 4 5 6 7 8 9 10
ARCHITECT/ENGINEER OF RECORD
Calvin rchitects, P.C.L 3705 North 200th Street
Elkhorn, Nebraska 68022
Phone: 402.291.6941 POC:
AH. INZ
6910 Pacific St #310
Omaha, NE 68106
Phone: 402.553.0234 POC:
IMEG Corp.
2882 106th Street
Des Moines, Iowa
Phone: 515.334.4303
POC:
AMI Enviromental
8802 S 135th Street
Omaha, NE 68138
Phone: 402.397.5001
POC:
BID SET 07/17/2019
Dwg. of 73
C R e v it L o c a l F ile s \M
E P
T
.0
V
A M a ri o n
B
R e n o
C
S c o tt .R
.P rz y b y s z im e g c o rp .c o m
.r v t
/1
/2
:5
:2
A
M
15-FP101
FIRST FLOOR PLAN - FIRE
PROTECTION
RENOVATE BUILDING 15
VAHCS MARION, IL
657A5-18-111
07/17/2019 IMEG IMEG
N O R
HT
1/4" = 1'-0"1
FLOOR PLAN - FIRE PROTECTION
GENERAL SHEET NOTES:
1. REFER TO 15-FP-001 FOR MORE INFORMATION.
SB
SS
0 HZ
0 SB
MINIMUM 16 GAGE GALVANIZED STEEL
PLATE 12"x48" [300x1200mm] MIN.
SECURED TO A MIN. 4 STUDS PER
LAVATORY
1/4" [6mm]∅ MOLLY BOLT HOLLOW WALL
ANCHOR (1 EA. SIDE OF LAV)
MIN. (3) 1/4" [6mm]
MACHINE BOLTS
W/DOUBLE LOCK NUTS
ON BACK SIDE
MIN. 5 1/4" [131mm]∅
GALV. MACHINE BOLTS
WELDED TO PLATE
1/4" [6mm]
TYP. 1/8"
TYP. [3mm]
A A
PLAN
SECTION A
STEEL HANGER BY LAV MFGR
STEEL WALL PLATE
WALL ANCHOR
STUDS
FOR FIXTURE
HEIGHT SEE
ARCHITECTURAL
DRAWINGS
[9 m m
T O
F L
O O
R
V A
R
IE
S
PLUMBING SYMBOL LIST
SYMBOL: DESCRIPTION:
PIPE SERVING FIXTURE ON FLOOR ABOVE
(EXAMPLE: FD = FLOOR DRAIN)FD
PITCH PIPE IN DIRECTION
RD-1
6"(1000)
ROOF DRAIN PROPERTIES SYMBOL
SIZE (ROOF SQ. FT.)
DIELECTRIC CONNECTION
UNION/FLANGE
BALANCING VALVE (NUMBER INDICATES GPM)
GPM
CHECK VALVE
REDUCER - REFERENCE SPECIFICATION
FOR CONCENTRIC/ECCENTRIC AND FOT/FOB
METERM
ALIGNMENT GUIDE
PIPE ANCHOR
EXPANSION JOINT
PIPE CAP
PIPE DOWN
PIPE UP OR UP/DOWN
DIRECTION OF FLOW IN PIPE
NEW CONNECTION
SHUTOFF VALVE NORMALLY OPEN
SHUTOFF VALVE NORMALLY CLOSED
COLD WATER - POTABLECW
DT DRAIN TILE
SANITARY DRAINAGE (GREASE SANITARY DRAINAGE)GSAN
HOT WATER - POTABLEHW
HOT WATER CIRCULATING - POTABLEHWC
HOT WATER - POTABLE NUMBER INDICATES TEMPHW140
HOT WATER CIRC. - POTABLE NUMBER INDICATES TEMPHWC140
NON-POTABLE COLD WATERNCW
NON-POTABLE HOT WATERNHW
PUMPED DISCHARGEPD
SANITARY DRAINAGESAN
SOFT COLD WATERSCW
SOFT HOT WATERSHW
STORM DRAINAGE (ROOF SQUARE FOOTAGE)ST(1,000)
STS STORM DRAINAGE (SECONDARY)
VENTV
COMPRESSED AIRCA
STW SOFT TEMPERED WATER
TW TEMPERED WATER
DRAIND
G NATURAL GAS
NOT ALL SYMBOLS MAY APPLY.
PRESSURE REDUCING VALVE (LIQUID/GAS)
SOLENOID VALVE
SAFETY/RELIEF VALVE
VACUUM BREAKER
PRESSURE GAUGE (FURNISHED WITH BALL VALVE)P
TEMPERATURE SENSOR WITH WELL
T
THERMOMETER WITH WELL (DIAL TYPE)T
THERMOMETER WITH WELL (FILLED TYPE)
PUMP
GRV GAS REGULATOR VENT
PURE WATERPW
SERVICE WATER - POTABLEW
PIPE CONTINUATION
PRESSURE SENSOR (FURNISHED WITH BALL VALVE)P
ROUTE TO DRAIN
PLUMBING SYMBOL LIST
BATHTUBBT
CO CLEANOUT
CLINICAL SINKCS
DRINKING FOUNTAINDF
EMERGENCY EYEWASHEE
FLOOR CLEANOUTFCO
FLOOR DRAINFD
FLOOR SINKFS
GARBAGE DISPOSERGD
GREASE INTERCEPTORGI
HOSE BIBBHB
I.E. INVERT ELEVATION (FOR REFERENCE ONLY)
LAVATORYLAV
MOP BASINMB
MH MANHOLE
MIXING VALVEMV
NEUTRALIZATION TANKNT
OIL SEPARATOROS
ROOF DRAINRD
SHOWERSH
SINKSK
SERVICE SINKSS
TRENCH DRAINTD
TRAP PRIMERTP
URINALUR
WATER CLOSETWC
WALL CLEANOUTWCO
WASH FOUNTAINWF
WATER HEATERWH
WASHING MACHINE FIXTUREWMF
YARD CLEANOUTYCO
EMERGENCY SHOWERES
EMERGENCY SHOWER/EYEWASHESE
ELECTRIC WATER COOLEREWC
VENT THROUGH ROOFVTR
AD ACCESS DOOR
ABOVE FINISHED FLOORAFF
BFP BACKFLOW PREVENTER
NC NEW CONNECTION
NOT IN CONTRACTNIC
ABBR: DESCRIPTION:
TYPICALTYP
UNLESS NOTED OTHERWISEUNO
EXISTINGE
FLOW METERFM
WATER SOFTENERWS
WATER METERWM
DIALYSIS BOXDB
CATCH BASINCB
CAST IRONCI
DUCTILE IRONDI
UTILITY BOXUB
NOT ALL SYMBOLS MAY APPLY.
PLAN OR DETAIL NUMBER
PLAN OR DETAIL NAME
PLAN OR DETAIL SCALE
DETAIL REFERRED TO BY SECTION CUT
SHEET DETAIL IS LOCATED ON
NAME
VIEW NAME
1/8" = 1'-0"
M101
T101
SIM
DETAIL REFERRED TO BY ELEVATION
SHEET DETAIL IS LOCATED ON
INDICATES SIMILAR DETAIL
REFERENCED IN MULTIPLE LOCATIONS
SIM
INDICATES SIMILAR DETAIL
REFERENCED IN MULTIPLE LOCATIONS
LEVEL NAME
10' - 0" HEIGHT ABOVE
PROJECT 0' - 0"
1 INDICATES NOTE USED TO DESCRIBE
ADDITIONAL INFORMATION ABOUT
WORK REQUIRED, SPECIFIC TO THE
SHEET AND/OR DETAIL
N
O R HT
INDICATES DIRECTION OF TRUE NORTH
VIEW KEY
NEW WORK BY THIS CONTRACTOR
(DARK SOLID LINE)
NEW WORK UNDERFLOOR OR UNDERGROUND BY THIS CONTRACTOR
(DARK LONG DASHED LINE)
EXISTING TO REMAIN
(LIGHT SOLID LINE)
EXISTING TO BE REMOVED BY THIS CONTRACTOR
(DARK SHORT DASHED LINE)
LINE TYPE KEY:
NEW PARTITION KEY WALL RATING DESCRIPTION
2 HR
BUILDING SEPARATION:
FIRE BARRIER
1 HR
OCCUPANCY / AREA SEPARATION:
FIRE BARRIER
2 HR
OCCUPANCY / AREA SEPARATION:
FIRE BARRIER
2 HR
1 HR
VERT. OPG. (EXIT ENCLSR/SHAFT)
FIRE BARRIER
(2 HR = 4 OR MORE STORIES)
(1 HR = LESS THAN 4 STORIES)
2 HR
1 HR
EXIT PASSAGEWAY (HORIZ)
FIRE BARRIER
1 HR
HAZ / INCIDENTAL USE
FIRE BARRIER
NR-
RESIST
SMK
HAZ / INCIDENTAL USE
SMOKE PARTITIONS (SPRINKLERED)
1 HR
1/2 HR
SUBDIVIDING SPACES
SMOKE BARRIER
NR
SUITE SEPARATION
SMOKE PARTITIONS
HORIZONTAL BUILDING SEPARATION
FIRE BARRIER
2 HR
FIRE/SMOKE BARRIER DESIGNATIONS
THE LINE TYPES SHOWN ARE FOR THE CONVENIENCE OF THE CONTRACTOR. THE CONTRACTOR' SHALL VERIFY RATINGS WITH THE LATEST SET OF ARCHITECTURAL PLANS AND FURNISH ALL MATERIALS REQUIRED TO COMPLY WITH THOSE RATINGS
WHETHER SHOWN OR NOT.
RATINGS WERE ACQUIRED FROM THE ARCHITECTURAL PLANS DATED 03/28/2019
TEMPERATURE CONTROLS CONTRACTORT.C.C.
CIVIL CONTRACTORC.C.
FIRE PROTECTION CONTRACTORF.P.C.
PLUMBING CONTRACTORP.C.
GENERAL CONTRACTORG.C.
MECHANICAL CONTRACTORM.C.
ELECTRICAL CONTRACTORE.C.
CONTRACTOR ABBREVIATION KEY
ABBR: DESCRIPTION:
1. THE SYMBOLS AND SCHEDULES ARE FOR THE CONVENIENCE OF THE CONTRACTOR.
CONTRACTOR SHALL VERIFY QUANTITIES AND FURNISH ALL MATERIALS REQUIRED FOR
FULLY OPERATIONAL SYSTEMS, WHETHER SPECIFIED OR NOT.
2. CATALOG NUMBERS, IF LISTED, SHALL NOT BE CONSIDERED COMPLETE, BUT ARE GIVEN AS
AN AID TO THE CONTRACTOR AND TO INDICATE THE QUALITY REQUIRED. CONTRACTOR IS
RESPONSIBLE FOR A COMPLETE DESCRIPTION OF MATERIAL ON THESE DRAWINGS AND IN
THE SPECIFICATIONS BEFORE ORDERING. THE DESCRIPTION OF THE MATERIAL TAKES
PRECEDENCE OVER THE CATALOG NUMBER, IF MANUFACTURERS ARE LISTED, THE FIRST
MANUFACTURER LISTED IS THE BASIS OF DESIGN.
3. CONTRACTOR SHALL VERIFY THAT FIXTURES SUPPLIED ARE APPROVED PER ALL
APPLICABLE STATE, LOCAL AND GOVERNING AUTHORITIES.
4. ALL FIXTURES SHALL CONFORM TO FEDERAL ACT S.3874
5. INVERT ELEVATIONS ARE NOT AVAILABLE FROM EXISTING DRAWINGS. VERIFY ALL
ELEVATIONS BEFORE BEGINNING WORK.
6. VERIFY UNDERGROUND PIPE SIZES AND LOCATIONS PRIOR TO BEGINNING ANY WORK.
7. REFER TO THE PLUMBING ROUGH-IN SCHEDULE FOR THE SIZES OF BRANCH PIPES TO
PLUMBING FIXTURES.
8. FOR CLARITY, NOT ALL VALVES HAVE BEEN SHOWN. PROVIDE SHUTOFF VALVES IN
DOMESTIC WATER PIPING SERVING EACH ROOM WITH FIXTURES. ANGLE STOPS SHALL NOT
BE CONSIDERED SHUTOFF VALVES.
9. EXISTING CONDITIONS ON DEMOLITION PLANS ARE PROVIDED TO INDICATE THE GENERAL
SCOPE OF ITEMS TO BE REMOVED. REFER TO SPECIFICATION SECTION 22 05 11 FOR
ADDITIONAL DEMOLITION INFORMATION.
10. P.C. SHALL CUT AND PATCH EXISTING AS REQUIRED FOR NEW OR DEMOLITION WORK
UNLESS NOTED OTHERWISE. REFER TO SPECIFICATION SECTION 22 05 11 FOR ADDITIONAL
INFORMATION.
PLUMBING GENERAL NOTES:
MECHANICAL GENERAL NOTES:
THESE NOTES APPLY TO ALL MECHANICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED
TO, FIRE PROTECTION, PLUMBING, VENTILATION, PIPING AND TEMPERATURE CONTROL.
1. DRAWINGS SHOWING LOCATIONS OF EQUIPMENT, DUCTWORK, PIPING, ETC. ARE
DIAGRAMMATIC AND MAY NOT ALWAYS REFLECT EXACT INSTALLATION CONDITIONS.
DRAWINGS SHOW THE GENERAL ARRANGEMENT OF DUCTWORK, PIPING, EQUIPMENT, ETC.,
AND MAY NOT INCLUDE ALL OFFSETS AND FITTINGS REQUIRED FOR COMPLETE
INSTALLATION. THE DRAWINGS SHALL BE FOLLOWED AS CLOSELY AS ACTUAL BUILDING
CONSTRUCTION AND THE WORK OF OTHERS WILL PERMIT.
2. DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS AND CLEARANCES FROM
ARCHITECTURAL, STRUCTURAL, SUBMITTALS, AND OTHER APPROPRIATE DRAWINGS OR
PHYSICALLY AT SITE. REVIEW ALL DRAWINGS, INCLUDING THOSE OF OTHER TRADES.
3. COORDINATE ALL WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION TO PROVIDE
CLEARANCES REQUIRED FOR OPERATION, MAINTENANCE, CODE COMPLIANCE, AND TO
VERIFY NON-INTERFERENCE WITH OTHER WORK. DO NOT FABRICATE PRIOR TO
VERIFICATION OF NECESSARY CLEARANCES FOR ALL TRADES. BRING ANY INTERFERENCES
OR CONFLICTS TO THE ATTENTION OF THE ARCHITECT/ENGINEER BEFORE PROCEEDING
WITH FABRICATION OR EQUIPMENT ORDERS.
4. REVIEW SPACE REQUIREMENTS OF EQUIPMENT SPECIFIED OR SUBSTITUTED AND MAKE
REASONABLE ACCOMMODATIONS IN LAYOUT AND POSITIONING TO PROVIDE PROPER
ACCESS.
5. ANY CHANGES REQUIRED TO ELIMINATE CONFLICTS OR THAT RESULT FROM A FAILURE TO
COORDINATE SHALL BE MADE BY THE CONTRACTOR WITHOUT ADDITIONAL COST OR
EXPENSE TO OTHERS.
6. EACH CONTRACTOR IS RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH ELECTRICAL
CHANGES REQUIRED FOR EQUIPMENT PROPOSED THAT DIFFERS FROM THE BASIS OF
DESIGN.
7. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN, ELECTRICAL, TECHNOLOGY
AUDIO/VISUAL, AND OTHER MECHANICAL PLANS FOR EXACT LOCATIONS OF ALL CEILING
MOUNTED DEVICES, OTHER THAN SPRINKLERS.
8. EACH CONTRACTOR IS RESPONSIBLE FOR DAMAGE CAUSED BY THEIR ACTIONS TO WALLS,
FLOORS, CEILINGS, AND ROOFS. THE CONTRACTOR WHOSE WORK CAUSES DAMAGE IS
RESPONSIBLE FOR PATCHING TO MATCH ORIGINAL CONSTRUCTION, FIRE RATING, AND
FINISH.
9. IN AREAS WITH DRYWALL CEILINGS COORDINATE LOCATIONS OF ACCESS PANELS WITH THE
GC FOR ACCESS TO VALVES, DUCTWORK ACCESSORIES, DAMPERS, ETC. COORDINATE
PANEL TYPE AND COLOR WITH ARCHITECT. NOTIFY THE GC OF THE REQUIRED ACCESS
PANELS PRIOR TO BIDDING.
10. SEAL ALL FLOOR, WALL, AND ROOF PENETRATIONS AIRTIGHT WHERE PIPING PENETRATE.
PENETRATIONS THROUGH EXTERIOR WALLS AND ROOF SHALL BE SEALED AIRTIGHT WITH
WATERPROOFING MATERIALS RECOMMENDED BY MANUFACTURER FOR OUTDOOR USE.
11. CAULK ALL PIPE PENETRATIONS OF FULL HEIGHT NON-FIRE RATED WALL, PARTITION,
FLOOR, AND ROOF ASSEMBLIES. THIS IS ESSENTIAL TO PREVENT NOISE TRANSMISSION
FROM ONE ROOM TO ANOTHER AND TO PROVIDE THE DESIRED NC LEVELS WITHIN ROOMS.
12. EQUIPMENT SIZES AND SERVICE CLEARANCE REQUIREMENTS VARY AMONG DIFFERENT
MANUFACTURERS. CONSULT APPROVED SHOP DRAWINGS FOR EQUIPMENT SIZES AND
REQUIRED SERVICE CLEARANCES. COORDINATE WITH LAYOUT OF EQUIPMENT PADS,
PIPING, DUCTWORK, ETC.
13. DO NOT BLOCK TUBE PULL OR EQUIPMENT SERVICE CLEARANCES.
14. MAINTAIN MINIMUM 3'-6” CLEARANCE IN FRONT OF ALL ELECTRICAL PANELS, MOTOR
STARTERS, SWITCHES, AND DISCONNECTS.
15. PROVIDE CONCRETE EQUIPMENT PAD FOR ALL FLOOR MOUNTED EQUIPMENT. PAD SHALL
EXTEND MINIMUM 6” BEYOND ALL SIDES OF EQUIPMENT.
16. DO NOT SUPPORT EQUIPMENT OR PIPING FROM METAL DECKING OR OTHER NON-
STRUCTURAL BUILDING ELEMENTS. ANCHORS EMBEDDED IN CONCRETE SHALL BE
CRACKED CONCRETE APPROVED IN ACCORDANCE WITH SPECIFICATIONS.
17. INSTALL PIPING AND DUCTWORK A MINIMUM OF 2" ABOVE CEILING TO ALLOW FOR CEILING
PANEL REMOVAL/INSTALLATION.
18. INSTALL ITEMS REQUIRING ACCESS SUCH AS EQUIPMENT, DAMPERS, OR VALVES AT A
HEIGHT NO GREATER THAN WHAT CAN BE ACCESSED FROM A 10-FOOT TALL STEPLADDER.
MECHANICAL RENOVATION NOTES:
THESE NOTES APPLY TO ALL MECHANICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED
TO FIRE PROTECTION, PLUMBING, VENTILATION, PIPING AND TEMPERATURE CONTROL.
1. EXISTING CONDITIONS ARE SHOWN BASED ON INFORMATION OBTAINED FROM FIELD
SURVEYS, EXISTING BUILDING DOCUMENTS, AND STAFF. CONTRACTOR SHALL VERIFY
EXISTING CONDITIONS PRIOR TO BIDDING AND REPORT ANY CONFLICTS BEFORE
PROCEEDING.
2. NOT ALL EXISTING DUCTWORK AND PIPING IS SHOWN. VERIFY EXISTING CONDITIONS
BEFORE STARTING WORK. VERIFY EXISTING DUCT AND PIPING CONDITIONS PRIOR TO
BIDDING. NOTIFY ENGINEER OF ANY CONFLICTS WITH NEW WORK.
3. FIELD VERIFY THE AVAILABLE CLEARANCES FOR DUCTWORK AND PIPING BEFORE
FABRICATION. RISES AND DROPS MAY BE NECESSARY BECAUSE OF EXISTING FIELD
CONDITIONS.
4. EACH CONTRACTOR SHALL FIELD VERIFY ACCESSIBILITY TO THE AREA OF HIS/HER WORK
AND SHALL NOTIFY THE GENERAL CONTRACTOR PRIOR TO BIDDING IF OTHER UTILITIES ARE
REQUIRED TO BE REMOVED OR RELOCATED TO ALLOW ACCESS TO HIS/HER AREA OF
WORK.
5. EACH CONTRACTOR SHALL CUT AND PATCH ROOFS, WALLS AND FLOORS ASSOCIATED
WITH HIS WORK.
6. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND REPLACEMENT OF
CEILINGS, CEILING TILES, AND CEILING GRIDS ASSOCIATED WITH AREAS OF WORK BY ALL
CONTRACTORS. NOTIFY THE GENERAL CONTRACTOR OF AFFECTED AREAS PRIOR TO
BIDDING.
7. WHERE EXISTING MECHANICAL SYSTEMS ARE LOCATED IN AREAS THAT CONFLICT WITH
NEW EQUIPMENT, PIPING, OR DUCTWORK TO BE INSTALLED, EACH CONTRACTOR SHALL
EITHER ARRANGE NEW EQUIPMENT, PIPING, OR DUCTWORK IN SUCH A FASHION THAT IT
DOES NOT CONFLICT WITH EXISTING SYSTEMS, OR REWORK EXISTING MECHANICAL
SYSTEMS TO ALLOW FOR INSTALLATION OF NEW EQUIPMENT, PIPING, OR DUCTWORK.
8. PROVIDE TEMPORARY CONNECTIONS TO MAINTAIN EXISTING SYSTEMS IN SERVICE DURING
CONSTRUCTION. MAINTAIN ACCESS TO EXISTING MECHANICAL INSTALLATIONS THAT
REMAIN ACTIVE.
9. OBTAIN PERMISSION FROM OWNER BEFORE SHUTTING DOWN ANY SYSTEM FOR ANY
REASON. ALL SYSTEM SHUTDOWNS WILL REQUIRE 3 WEEKS NOTICE PRIOR TO THE
SHUTDOWN EVENT. MAINTAIN SERVICE TO ALL COMPONENTS THAT ARE TO REMAIN UNTIL
NEW SYSTEMS ARE INSTALLED.
10. MAINTAIN EXISTING SYSTEM IN SERVICE UNTIL NEW SYSTEM IS COMPLETE AND READY FOR
TIE IN AND SWITCHOVER. DRAIN SYSTEM ONLY TO MAKE SWITCHOVERS AND
CONNECTIONS. OBTAIN PERMISSION FROM OWNER BEFORE PARTIALLY OR COMPLETELY
DRAINING SYSTEM. MAKE CHANGEOVER TO NEW SYSTEMS WITH MINIMUM OUTAGE.
11. DISCONNECT AND REMOVE MECHANICAL DEVICES AND EQUIPMENT SERVING EQUIPMENT
THAT HAS BEEN REMOVED.
MECHANICAL PHASING NOTES:
THESE NOTES APPLY TO ALL MECHANICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED
TO, FIRE PROTECTION, PLUMBING, VENTILATION, PIPING AND TEMPERATURE CONTROL.
1. REFER TO ARCHITECTURAL DRAWINGS FOR GENERAL DESCRIPTION OF PHASES. REFER TO
ARCHITECT'S INSTRUCTIONS FOR MORE DETAILS, PHASING SCHEDULES AND FOR
CONCURRENT WORK. MECHANICAL, ELECTRICAL AND TECHNOLOGY DRAWINGS DEPICT
THE INTENT OF THE FINAL DESIGN. THE MECHANICAL, ELECTRICAL, AND TECHNOLOGY
DRAWINGS DO NOT DEPICT THE MEANS AND METHODS TO MEET THE REQUIREMENTS OF
THE PHASING CRITERIA.
2. REVIEW PROJECT PHASING PLANS TO COORDINATE DEMOLITION WORK, OUTAGES, ETC.
WITH AFFECTED ADJACENT AREAS.
3. PROVIDE AND INSTALL TEMPORARY DUCTWORK, PIPING, SHUTOFF VALVES, ETC. AS
NECESSARY TO KEEP ALL OCCUPIED SPACES OPERATIONAL THROUGHOUT ALL PHASES OF
THE PROJECT.
4. PHASE DEMOLITION WORK TO MINIMIZE DOWNTIME.
DEDUCT ALTERNATE NOTES:
THESE NOTES APPLY TO ALL MECHANICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED
TO FIRE PROTECTION, PLUMBING, VENTILATION, PIPING, AND TEMPERATURE CONTROL.
1. REFER TO ARCHITECTURAL PLANS AND SPECIFICATIONS FOR DEDUCT ALTERNATE INFORMATION.
CW
HW
HWC
C W
H W
CIRCULATING
PUMP CP-1
SIZE AND ROUTE BYPASS
PER MIXING VALVE
MANUFACTURER'S REQUIRED
PIPING METHOD.
3/4" TEST VALVE
VACUUM BREAKER.
WATTS MODEL 8A OR EQUAL
WITH HOSE THREAD AND CAP.
THERMOMETER IN WELL (0-200° F)
VACUUM RELIEF VALVE.
WATTS N36 OR EQUIVALENT
EXPANSION TANK
MIXING VALVE LOCATE BELOW TOP OF
WATER HEATER OR PROVIDE HEAT
TRAP WITH DEPTH AS REQUIRED BY
MIXING VALVE MANUFACTURER. VERIFY
EXACT PIPING AND BALANCING
REQUIREMENTS WITH MANUFACTURER.
BALANCING VALVE IF
REQUIRED BY MIXING
VALVE MANUFACTURER'S
PIPING METHOD.
DRAIN
A.S.M.E. PRESSURE AND
TEMPERATURE RELIEF VALVE
UNION (TYP.)
PIPE DIRECTLY OVER
FLOOR DRAIN.
HOUSEKEEPING PAD
WH-1
SET AT 140º
FIRE SEALANT
FIRE SEALANT
NOTE 2
NOTE 3
PENETRATING ITEM
NOTE 4
NOTE 3
NOTE 4
PENETRATING ITEM
NOTE 2
NOTE 3
RATED WALL
(CONSTRUCTION
VARIES)
RATED FLOOR
(CONSTRUCTION
VARIES)
NOTES:
1. THIS GENERAL DETAIL APPLIES TO ALL ITEMS PENETRATING FIRE RATED WALLS OR
FLOORS. THE INTENT IS TO MAINTAIN THE FIRE RATING AND TO ALLOW
LONGITUDINAL MOVEMENT. REFER TO SPECIFICATION SECTION 07 84 00 FOR
SELECTION OF THROUGH PENETRATION FIRE STOPPING.
2. SCHEDULE 5 PIPE SLEEVE EMBEDDED IN WALL OR FLOOR, OR SMOOTH CORE DRILL.
EACH CONTRACTOR FURNISHES SLEEVE TO G.C., COORDINATES SLEEVE LOCATIONS
AND DEBURS SLEEVE. G.C. BUILDS SLEEVE INTO WALL OR FLOOR ALLOWING NO GAP
AROUND SLEEVE. IF SLEEVE IS NOT PROVIDED WHEN WALL OR FLOOR IS BUILT,
CONTRACTOR SHALL INSTALL SLEEVE. SLEEVE SIZE SHALL ALLOW ANNULAR SPACE
REQUIRED BY THE SELECTED FIRE STOP SYSTEM.
3. INSTALL BACKING MATERIAL, SUCH AS MINERAL WOOL SAFING, AS REQUIRED FOR
FIRE STOP SYSTEM. INSTALL IN ACCORDANCE WITH FIRE STOP SYSTEM APPLICATION
LISTING. SECURE TO WALL OR FLOOR TO ALLOW LONGITUDINAL MOVEMENT OF
PENETRATING ITEM WITHOUT MOVEMENT OF FIRE BARRIER.
4. WATERTIGHT WELDED 1"x1" 20 GAUGE MINIMUM GALVANIZED SHEET METAL ANGLE
FRAME, BY CONTRACTOR IN EQUIPMENT ROOMS FOR WATER STOP. PLACE A BEAD
OF WATERPROOF SEALANT BETWEEN FLOOR AND BOTTOM OF ANGLE FRAME.
SECURE TO FLOOR WITH MASONRY ANCHORS IN CORNERS AND ON 12" MAXIMUM
CENTERS. MULTIPLE PENETRATING ITEMS MAY BE ENCLOSED IN ONE FRAME.
NOTES: 1) SANITARY RISER UP IN WALL TO FIXTURE SHALL BE A MINUMUM OF 2". 2) 1/2" CW AND HW APPLIES ONLY TO THE FINAL VERTICAL RISE-DROP TO EACH FIXTURE, BRANCH PIPING TO VERTICAL RISE-DROP SHALL BE A MINIMUM OF 3/4" UNLESS NOTED OTHERWISE. 3) SIZES SHOWN ARE MINIMUMS.
SIZES SHOWN ON THE DRAWING THAT ARE LARGER THAN THE SIZES LISTED IN THE SCHEDULE SHALL
DICTATE THE ROUGH-IN SIZE.
PLUMBING FIXTURE ROUGH-IN SCHEDULE
FIXTURE DESCRIPTION
DOMESTIC
CW
(NOTE 3)
DOMESTIC
HW
(NOTE 3)
SANITARY
(NOTE 3)
VENT
(NOTE 3) REMARKS
EXISTING ELECTRIC WATER
COOLER
1/2" - 1 1/2" 1 1/4" NOTE 1 & 2
FLOOR DRAIN/FLOOR SINK - - 2" 1 1/2" -
FLOOR DRAIN/FLOOR SINK - - 3" 1 1/2" -
FUTURE BREAK ROOM SINK 1/2" 1/2" 1 1/2" 1 1/2" NOTES 1 & 2
HOSE BIBB P-801 3/4" - - - -
LAVATORY P-408 1/2" 1/2" 1 1/4" 1 1/4" NOTE 1 & 2
SHOWER 1/2" 1/2" 2" 1 1/2" NOTE 2
WATER CLOSET P-115 1" - 4" 2" -
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID SET
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMP
321 4 5 6 7 8 9 10
ARCHITECT/ENGINEER OF RECORD
Calvin rchitects, P.C.L 3705 North 200th Street
Elkhorn, Nebraska 68022
Phone: 402.291.6941 POC:
AH. INZ
6910 Pacific St #310
Omaha, NE 68106
Phone: 402.553.0234 POC:
IMEG Corp.
2882 106th Street
Des Moines, Iowa
Phone: 515.334.4303
POC:
AMI Enviromental
8802 S 135th Street
Omaha, NE 68138
Phone: 402.397.5001
POC:
BID SET 07/17/2019
Dwg. of 73
C R e v it L o c a l F ile s \M
E P
T
.0
V
A M a ri o n
B
R e n o
C
S c o tt .R
.P rz y b y s z im e g c o rp .c o m
.r v t
/1
/2
:0
:2
P
M
15-P-001
PLUMBING COVER SHEET RENOVATE BUILDING 15
VAHCS MARION, IL
657A5-18-111
07/17/2019 IMEG IMEG
NO SCALE3
LAVATORY MOUNTING DETAIL
FLOOR DRAIN FD-V
FLOOR DRAIN FD-C
FLOOR DRAIN FD-D
MOP SINK P-502
FLOOR DRAIN FD-W
HOSE BIBB P-804
HOSE BIBB P-805
SHOWER P-702
3/4"
3/4"
3/4"
3/4"
4"
3"
3"
2"
1 1/2"
1 1/2"
NO SCALE1
MIXING VALVE (AT SOURCE) PIPING DETAIL
NO SCALE2
RATED FIRE BARRIER PENETRATION
OI+T
TOILET
PLUMBING SHOP
PROJECTS
SECTION
FILE
STORAGE
ELECTRIC
VAULT
MEN TOILET
TOILET
CHIEF ENGR.
WOMEN TOILET
ENGINEERING
CLERKS
MISC STORAGE
FACILITY
PLANNER
PROJECT
SUPERVISOR
ENERGY
MANAGER
CONFERENCE /
BREAKROOM
ASSIST
CHIEF
SHOWER
HAC
111A
105 105A
102A
109A 107A
104A
FD
4" V UP
LAV
WC
CO
4" V UP
WC
2"SAN
EWC
LAV
WC
4" V UP
4"SAN
LAV
WC
4"SAN
2"CW
REMOVE ABANDONED 2"CW AND
ASSOCIATED METER/CONDUIT.
4" ST
3/4" G
4" ST
SAWCUT FLOOR AS
NECESSARY TO REMOVE
EXISTING SANITARY PIPING.
SAWCUT FOR NEW
PLUMBING FIXTURE
SANITARY ROUTE.
SAWCUT FOR NEW
PLUMBING FIXTURE
SANITARY ROUTE.
SAWCUT FOR NEW
PLUMBING FIXTURE
SANITARY ROUTE.
SAWCUT FOR NEW
PLUMBING FIXTURE
SANITARY ROUTE.
A
B
1 2 3
REMOVE PIPING AS INDICATED UP
TO EDGE OF VAULT. FILL
EXISTING PIPING AND FLOOR
DRAIN WITH CONCRETE AND CAP.
PIPING TO BE ABANDONED.
PROVIDE TEMPORARY CONNECTION FROM EXISTING TO
NEW SANITARY PIPING TO KEEP EAST BATHROOMS
OPERATIONAL DURING PHASE 1. ONCE PHASE 2 IS
STARTED THEN PIPING UNDER VAULT CAN BE CUT,
CAPPED, AND FILLED AND REMAINING SECTION OF
FLOOR IN 101C CAN BE FILLED.
REMOVE 2"CW LINE BACK
INTO WALL AS FAR AS
POSSIBLE TO BE ABLE TO
MAKE A NEW CONNECTION.
FCO
FD
SAWCUT FOR NEW PLUMBING
FIXTURE SANITARY ROUTE.
4"SAN
FD
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID SET
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMP
321 4 5 6 7 8 9 10
ARCHITECT/ENGINEER OF RECORD
Calvin rchitects, P.C.L 3705 North 200th Street
Elkhorn, Nebraska 68022
Phone: 402.291.6941 POC:
AH. INZ
6910 Pacific St #310
Omaha, NE 68106
Phone: 402.553.0234 POC:
IMEG Corp.
2882 106th Street
Des Moines, Iowa
Phone: 515.334.4303
POC:
AMI Enviromental
8802 S 135th Street
Omaha, NE 68138
Phone: 402.397.5001
POC:
BID SET 07/17/2019
Dwg. of 73
C R e v it L o c a l F ile s \M
E P
T
.0
V
A M a ri o n
B
R e n o
C
S c o tt .R
.P rz y b y s z im e g c o rp .c o m
.r v t
/1
/2
:0
:2
P
M
15-PD100
FIRST FLOOR PLAN - PLUMBING
UNDERFLOOR DEMOLITION
RENOVATE BUILDING 15
VAHCS MARION, IL
657A5-18-111
07/17/2019 IMEG IMEG
N
O R HT
1/4" = 1'-0"1
FLOOR PLAN - PLUMBING UNDERFLOOR DEMOLITION
GENERAL SHEET NOTES:
1. EXISTING UNDERFLOOR PIPING SHOWN BASED
UPON SITE PLAN AND EXISTING FIXTURES.
CONTRACTOR TO VERIFY EXISTING SANITARY
ROUTING USING SCOPE OR OTHER METHODS
PRIOR TO DEMOLITION.
2. REFER TO 15-P-001 FOR MORE INFORMATION.
OI+T
TOILET
PLUMBING SHOP
PROJECTS
SECTION
FILE
STORAGE
ELECTRIC
VAULT
MEN TOILET
TOILET
CHIEF ENGR.
WOMEN TOILET
ENGINEERING
CLERKS
MISC STORAGE
FACILITY
PLANNER
PROJECT
SUPERVISOR
ENERGY
MANAGER
CONFERENCE /
BREAKROOM
ASSIST
CHIEF
SHOWER
HAC
111A
105 105A
102A
109A 107A
104A
M & O
SUPERV.
OI+T
TOILET
PLUMBING SHOP
PROJECTS
SECTION
FILE
STORAGE
ELECTRIC
VAULT
MEN TOILET
TOILET
CHIEF ENGR.
WOMEN TOILET
ENGINEERING
CLERKS
MISC STORAGE
FACILITY
PLANNER
PROJECT
SUPERVISOR
ENERGY
MANAGER
CONFERENCE /
BREAKROOM
ASSIST
CHIEF
SHOWER
HAC
111A
105 105A
102A
109A 107A
104A
A
1 2
B
FD-A
REMOVE PLUMBING FIXTURES
AND ALL BRACKETS, HANGERS,
ACCESSORIES, ETC. (TYP.)
REMOVE EXISTING WATER
HEATER , EXPANSION TANK
AND ALL BRACKETS, HANGERS,
CONTROLS, WIRING,
ACCESSORIES, ETC.
REMOVE AND STORE FOR RELOCATION EXISTING
ELECTRIC WATER COOLER AND ALL BRACKETS,
HANGERS, CONTROLS, WIRING, ACCESSORIES, ETC.
REFER TO 15-PL-101 FOR NEW LOCATION.
EWC
1/2"CA 1/2"CA
1/2"CA
3/4"CW
REMOVE EXISTING AIR
COMPRESSOR AND ALL WIRES,
CONTROLS, PIPING, VALVES,
BRACKETS, HANGERS,
ACCESSORIES, ETC.
TD-E
4"ST WITH TRANSITION
FOR DOWNSPOUT
CONNECTION BELOW
CONCRETE
P-801
4"ST WITH TRANSITION
FOR DOWNSPOUT
CONNECTION BELOW
CONCRETE
P-801
WH-E
ET-E
4"ST WITH TRANSITION FOR
DOWNSPOUT CONNECTION
BELOW CONCRETE
4" ST CLEANOUT
APPROXIMATELY 12" AFF.
EXISTING NATURAL GAS
PRESSURE REGULATOR,
METER AND VALVES WITH
BTU METER.
CO
2"SAN
4" SAN CO 12" AFF
2" SAN
CO
4"ST WITH TRANSITION FOR DOWNSPOUT
CONNECTION AT APPROXIMATELY 30" AFF.
CLEANOUT ON Y-FITTING AT
APPROXIMATELY 6" AFF
P-801
/2 "C
W /4
"H W
4" VTR
4" V
3/4"CW
/4
"H W
4" V
/2 "C
W
REMOVE EXISTING 2" CW LINE DOWN BELOW FINISHED
FLOOR. COORDINATE PIPING REMOVAL, SHUT DOWN,
AND TEMPORARY CONNECTIONS WITH OWNER. EAST
PORTION OF BUILDING TO REMAIN OCCUPIED DURING
FIRST PHASE OF CONSTRUCTION.
REMOVE PIPING AS
INDICATED AND PREPARE
FOR NEW CONNECTION.
REMOVE EXISTING HOSE BIBBS
AND ALL BRACKETS, HANGERS,
ACCESSORIES, ETC. (TYP.)
FILL EXISTING FLOOR DRAIN
WITH CONCRETE. REFER TO
UNDERFLOOR PLAN FOR
MORE INFORMATION.
REMOVE PORTION OF 2" GAS
LINE BETWEEN SHUT OFF
VALVE AND GROUND IN
VERTICAL. PREPARE FOR
NEW CONNECTION.
REMOVE EXISTING
2"V FROM MAIN UP
THROUGH ROOF.
FD
FCO
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID SET
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMP
321 4 5 6 7 8 9 10
ARCHITECT/ENGINEER OF RECORD
Calvin rchitects, P.C.L 3705 North 200th Street
Elkhorn, Nebraska 68022
Phone: 402.291.6941 POC:
AH. INZ
6910 Pacific St #310
Omaha, NE 68106
Phone: 402.553.0234 POC:
IMEG Corp.
2882 106th Street
Des Moines, Iowa
Phone: 515.334.4303
POC:
AMI Enviromental
8802 S 135th Street
Omaha, NE 68138
Phone: 402.397.5001
POC:
BID SET 07/17/2019
Dwg. of 73
C R e v it L o c a l F ile s \M
E P
T
.0
V
A M a ri o n
B
R e n o
C
S c o tt .R
.P rz y b y s z im e g c o rp .c o m
.r v t
/1
/2
:0
:3
P
M
15-PD101
FIRST FLOOR PLAN - PLUMBING
DEMOLITION
RENOVATE BUILDING 15
VAHCS MARION, IL
657A5-18-111
07/17/2019 IMEG IMEG
N
O R HT
1/4" = 1'-0"1
FLOOR PLAN - PLUMBING DEMOLITION
GENERAL SHEET NOTES:
1. REFER TO 15-P-001 FOR MORE INFORMATION.
REMOVE EXISTING 4" PLUMBING
VENTS THROUGH ROOF.
REMOVE EXISTING 4" PLUMBING
VENTS THROUGH ROOF.
A
B
1 2 3
REMOVE EXISTING 2" V.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID SET
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMP
321 4 5 6 7 8 9 10
ARCHITECT/ENGINEER OF RECORD
Calvin rchitects, P.C.L 3705 North 200th Street
Elkhorn, Nebraska 68022
Phone: 402.291.6941 POC:
AH. INZ
6910 Pacific St #310
Omaha, NE 68106
Phone: 402.553.0234 POC:
IMEG Corp.
2882 106th Street
Des Moines, Iowa
Phone: 515.334.4303
POC:
AMI Enviromental
8802 S 135th Street
Omaha, NE 68138
Phone: 402.397.5001
POC:
BID SET 07/17/2019
Dwg. of 73
C R e v it L o c a l F ile s \M
E P
T
.0
V
A M a ri o n
B
R e n o
C
S c o tt .R
.P rz y b y s z im e g c o rp .c o m
.r v t
/1
/2
:0
:3
P
M
15-PD102
ROOF PLAN - PLUMBING
DEMOLITION
RENOVATE BUILDING 15
VAHCS MARION, IL
657A5-18-111
07/17/2019 IMEG IMEG
N
O R HT
1/4" = 1'-0"1
ROOF PLAN - PLUMBING DEMOLITION
GENERAL SHEET NOTES:
A
1 2
99 SF
PROJECT
ENGINEER
SUPERVISOR
100 SF/
Not Enclosed
PLAN ROOM
200 SF/
203 SF
BREAK ROOM
319 SF
CONFERENCE
ROOM
300 SF/
41 SF
UNISEX STAFF
TLT
60 SF/
70 SF
UNISEX STAFF
TLT
80 SF/
102 SF
OI&T ROOM
101D
100 SF/
46 SF
HAC
60 SF/
27 SF
ALCOVE
101B
196 SF
MECHANICAL
101C
488 SF/
61 SF
STORAGE
60 SF/
102 SF
ASST. CHIEF
ENGINEER
100 SF/ 102 SF
CHIEF ENGINEER
100 SF/ 100 SF
FACILITY
PLANNER
100 SF/ 96 SF
ENERGY
MANAGER
100 SF/
60 SF
MENS TOILET
60 SF/ 59 SF
WOMENS TOILET
60 SF/
99 SF
M&O
SUPERVISOR
100 SF/
14 SF
CLOSET
96 SF
M&O
SUPERVISOR
100 SF/
105 SF
M&O
SUPERVISOR
100 SF/
103 SF
M&O
SUPERVISOR
100 SF/
154 SF
CORRIDOR
C01
56 SF
ADMIN OFFICE
ASST
56 SF/ 117 SF
CORRIDOR
C01A
128 SF
CORRIDOR
C01B
196 SF
ELECTRICAL
105A
488 SF/
124 SF
CORRIDOR
C02
63 SF
VESTIBULE
Not Enclosed
STEAM TUNNEL
Not Enclosed
PROJECT
ENGINEERS
WORKSTATIONS
121A
116 SF
PROJECT
ENGINEERS
EGRESS
121B
32 SF
CORRIDOR
C01C
9 SF
SHOWER
118A
16 SF
STORAGE
C01D
B
2"CW
4" ST
3/4" G
4" ST
SAWCUT FROM DEMOLITION
WORK SHOWN FOR
REFERENCE
SAWCUT FOR NEW
PLUMBING FIXTURE
SANITARY ROUTE.
SAWCUT FOR NEW
PLUMBING FIXTURE
SANITARY ROUTE.
SAWCUT FOR NEW
PLUMBING FIXTURE
SANITARY ROUTE.
SAWCUT FOR NEW
PLUMBING FIXTURE
SANITARY ROUTE.
FCO
PROVIDE NEW 4" SANITARY MAIN.
CONTRACTOR SHALL FIELD VERIFY EXISTING
SYSTEM INVERT ELEVATION CONNECTION
POINT AND SLOPE NEW PIPING AS REQUIRED
PER CODE.
2" VENT UP FOR MAIN
VENTING
FCO
2" VENT UP FOR
SANITARY MAIN
VENTING
4"SAN
PROVIDE 4" PERFORATED DRAIN TILE ALONG
PERIMETER OF BUILDING.AT ELEVATION EQUAL TO
EXISTING FOOTING APPROXIMATELY 30" BELOW
GRADE. COORDINATE ROUTING WITH EXISTING
UNDERGROUND UTILITIES.
CONTRACTOR SHALL FIELD
VERIFY ROUTING OF DRAIN TILE
AND COORDINATE WITH EXISTING
UNDERGROUND UTILITIES.
YCO
CO
PROVIDE NEW 4" SANITARY MAIN. CONTRACTOR
SHALL FIELD VERIFY EXISTING SYSTEM INVERT
ELEVATION CONNECTION POINT AND SLOPE
NEW PIPING AS REQUIRED PER CODE.
FCO
2" SAN UP
SK
WC
WC
2" V UP
2" V UP
LAV
LAV
FD
FD
2" V UP
FD
EWC
FD
FD
WC
WC
LAVLAV
2" V UP
2" V UP
2" CW UP
NC
3" STANDPIPE
MB
PROVIDE TEMPORARY CONNECTION FROM
EXISTING TO NEW SANITARY PIPING TO KEEP
EAST BATHROOMS OPERATIONAL DURING
PHASE 1. ONCE PHASE 2 IS STARTED THEN
PIPING UNDER VAULT CAN BE CUT, CAPPED,
AND FILLED AND REMAINING SECTION OF
FLOOR IN 101C CAN BE FILLED.
CONNECT NEW 2"CW TO EXISTING
IN WALL. ROUTE PIPE AS CLOSE
AS POSSIBLE TO EXTERIOR WALL
WITHOUT CRUSHING INSULATION
STARTING INVERT ELEVATION
APPROXIMATELY 98.83' WITH
FINISH FLOOR AT 100.00'
STARTING INVERT ELEVATION
APPROXIMATELY 98.50' WITH
FINISH FLOOR AT 100.00'
PROVIDE 24" DIAMETER MINIMUM SUMP
PIT WITH GASKETED COVER AND VENT.
REFER TO SUMP PUMP SPECIFICATIONS
FOR SIZING INFORMATION.
ENDING INVERT ELEVATION
APPROXIMATELY 97.72' WITH
FINISH FLOOR AT 100.00'
FD
2" V UP
4"SA
N
4"SAN
"S
A N
4"
SA
N
2"SAN
4"SAN
2"SAN
4"SAN
2" V
4"SAN
2"SAN
4"
SA
N
"S
A N
"S
A N
"S
A N
4"SAN
4"SAN 3"SAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID SET
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMP
321 4 5 6 7 8 9 10
ARCHITECT/ENGINEER OF RECORD
Calvin rchitects, P.C.L 3705 North 200th Street
Elkhorn, Nebraska 68022
Phone: 402.291.6941 POC:
AH. INZ
6910 Pacific St #310
Omaha, NE 68106
Phone: 402.553.0234 POC:
IMEG Corp.
2882 106th Street
Des Moines, Iowa
Phone: 515.334.4303
POC:
AMI Enviromental
8802 S 135th Street
Omaha, NE 68138
Phone: 402.397.5001
POC:
BID SET 07/17/2019
Dwg. of 73
C R e v it L o c a l F ile s \M
E P
T
.0
V
A M a ri o n
B
R e n o
C
S c o tt .R
.P rz y b y s z im e g c o rp .c o m
.r v t
/1
/2
:0
:3
P
M
15-PL100
FIRST FLOOR PLAN - PLUMBING
UNDERFLOOR
RENOVATE BUILDING 15
VAHCS MARION, IL
657A5-18-111
07/17/2019 IMEG IMEG
N
O R HT
1/4" = 1'-0"1
FLOOR PLAN - PLUMBING UNDERFLOOR
GENERAL SHEET NOTES:
0 SB 0 SB0 SB 0 SB 0 SB
S
B S
B S
B S
B S
B S
B
S
B S
B S
B S
B S
B S
B
SS SSSS SS SS
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
A
1 2
99 SF
PROJECT
ENGINEER
SUPERVISOR
100 SF/
Not Enclosed
PLAN ROOM
200 SF/
203 SF
BREAK ROOM
319 SF
CONFERENCE
ROOM
300 SF/
41 SF
UNISEX STAFF
TLT
60 SF/
70 SF
UNISEX STAFF
TLT
80 SF/
102 SF
OI&T ROOM
101D
100 SF/
46 SF
HAC
60 SF/
27 SF
ALCOVE
101B
196 SF
MECHANICAL
101C
488 SF/
61 SF
STORAGE
60 SF/ 102 SF
ASST. CHIEF
ENGINEER
100 SF/ 102 SF
CHIEF ENGINEER
100 SF/ 100 SF
FACILITY
PLANNER
100 SF/ 96 SF
ENERGY
MANAGER
100 SF/
60 SF
MENS TOILET
60 SF/ 59 SF
WOMENS TOILET
60 SF/ 99 SF
M&O
SUPERVISOR
100 SF/
14 SF
CLOSET
96 SF
M&O
SUPERVISOR
100 SF/ 105 SF
M&O
SUPERVISOR
100 SF/ 103 SF
M&O
SUPERVISOR
100 SF/
154 SF
CORRIDOR
C01
56 SF
ADMIN OFFICE
ASST
56 SF/
117 SF
CORRIDOR
C01A
128 SF
CORRIDOR
C01B
196 SF
ELECTRICAL
105A
488 SF/
124 SF
CORRIDOR
C02
63 SF
VESTIBULE
Not Enclosed
STEAM TUNNEL
Not Enclosed
PROJECT
ENGINEERS
WORKSTATIONS
121A
116 SF
PROJECT
ENGINEERS
EGRESS
121B
9 SF
SHOWER
118A
32 SF
CORRIDOR
C01C
16 SF
STORAGE
C01D
B
172 SF
ENG.
CLERK/TRANS.MGR
101A
173 SF
LOBBY
496 SF
PROJECT
ENGINEERS
WORKSTATIONS
56 SF/
3/4"CW
4"ST WITH TRANSITION
FOR DOWNSPOUT
CONNECTION BELOW
CONCRETE
4"ST WITH TRANSITION
FOR DOWNSPOUT
CONNECTION BELOW
CONCRETE
4"ST WITH TRANSITION
FOR DOWNSPOUT
CONNECTION BELOW
CONCRETE
4" ST CLEANOUT
APPROXIMATELY 12" AFF.
EXISTING NATURAL GAS
PRESSURE REGULATOR,
METER AND VALVES
WITH BTU METER.
CO
4"ST WITH TRANSITION FOR DOWNSPOUT
CONNECTION AT APPROXIMATELY 30" AFF.
CLEANOUT ON Y-FITTING AT
APPROXIMATELY 6" AFF
TD-E
CONNECT TO EXISTING 2" CW
LINE LOCATED WITHIN 12" OF
THE FINISHED FLOOR.
FCO-1 PROVIDE 5 GALLON EXPANSION
TANK FOR DOMESTIC HOT
WATER SYSTEM
50 GALLON
ELECTRIC WATER
HEATER (WH-1)
CIRCULATION PUMP
FOR DOMESTIC HOT
WATER SYSTEM (CP-1)
3" FD-V
PROVIDE WITH TRAP
PRIMER (TP-2)
HOSE BIBB MOUNTED AT
APPROXIMATELY 18"
ABOVE GRADE
SUMP PUMP FOR
DRAIN TILE SYSTEM
2" FD-C
PROVIDE WITH TRAP
PRIMER (TP-2)
2" FD-C
PROVIDE WITH TRAP
PRIMER (TP-2)
PROVIDE ROUGH IN
INCLUDING ANGLE STOPS
FOR FUTURE SINK AT
THIS LOCATION.
HOSE BIBB MOUNTED AT
APPROXIMATELY 18"
ABOVE GRADE
HOSE BIBB MOUNTED AT
APPROXIMATELY 18"
ABOVE GRADE
FCO-1
2"V DOWN, 4"VTR
2"V DOWN, 4"VTR
FCO-1
4" VTR
2" V
2" V UP, 2 SAN DN
2" V
2"CW
2" V
BFP-1
2" V
4" FD-D
PROVIDE WITH TRAP
PRIMER (TP-2)
2" V
2"V UP,
2"SAN DN
0.5 GPM
2"CW
1 1/2"HW
3/4"CW 2"CW
4" VTR
P-804
3/4"CW UP TO HOSE
BIBB ON ROOF
2"V UP, 2"SAN DOWN
YARD CLEANOUT
TERMINATE 3" STANDPIPE
APPROXIMATELY 36" AFF.
ROUTE 2" PD TO STANDPIPE
AND TERMINATE WITH AIR GAP.
PROVIDE SHUT OFF
VALVES IN VERTICAL
COORDINATE MOUNTING
LOCATION AND ACCESS
PANEL REQUIREMENTS.
(TYP.)
PROVIDE HEAT TRACE FOR
CW LINE FROM INSIDE
BUILDING 15 INTO BUILDING
TO THE SOUTH.
COORDINATE WITH
ELECTRICAL CONTRACTOR.
PROVIDE SHUT OFF VALVE AND
WATER HAMMER ARRESTOR
PRIOR TO PIPING ENTERING WALL.
1 1/2"HW
2"CW
"C
W
/2 "H
W
"C
W
2"CW
2"CW
1 1/2"HW
2"CW
2"CW
1 1/2"CW
1 1/2"HWC
P-801
P-408
P-115
P-408
P-115
CONNECT NEW 1" GAS
LINE ON 2" GAS LINE
BETWEEN SHUT OFF
VALVE AND GROUND IN
VERTICAL.
P-801
3" FD-W
P-502
SUMP PUMP PANEL.
COORDINATE
LOCATION WITH
ELECTRICAL.
P-115
P-408
P-408
P-115
P-801
INSTALL EXISTING
WATER COOLER AT THIS
LOCATION.
2"CW
PROVIDE MASTER
THERMOSTATIC MIXING
VALVE SET TO 110°F
PROVIDE P-702 SHOWER TRIM WITH
THERMOSTATIC AND PRESSURE
MIXING VALVE AND FD-C 2" FLOOR
DRAIN FOR SHOWER DRAINAGE.
2" V
2" V FROM SUMP
BASIN COVER
PROVIDE SHUT OFF VALVE
F…