P09 Drawing Bid Set 21-04-21 2 of 7.pdf

PDF 12 MB Posted

Attached to
Z2DA--P/N 657A5-18-111, RENOVATE BUILDING 15
Solicitation number
36C25522R0046_1
Issued by

About this file

This document provides details on a federal contract opportunity to renovate Building 15. The solicitation number is 36C25522R0046_1 to renovate Building 15 under Project #657A-18-111. The opportunity is being offered by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 15. Interested parties are invited to submit bids to renovate the building in accordance with the drawings and specifications outlined in the P09 Drawing Bid Set file also referenced in the document. The renovation work is required to be completed under the terms specified in the solicitation.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SEALANT

EXISTING STUCCO

ROOFING MATERIAL TO OVERLAP

SCUPPER SHEET METAL

SEE MANUFACTURER'S SPECIFICATIONS

REFINISH EXIST CONDUCTOR HEAD;

REPLACE IF DAMAGED BEYOND REPAIR -

MATCH EXIST IF NEEDED

REPLACE SCUPPER WITH AN

IDENTICAL MODEL IN SIZE SHAPE, AND MATERIAL

TAPER INSULATION TO

SCUPPER OPENING

EXISTING CONCRETE ROOF DECK

EXIST STEEL TRUSS

EXIST DOWNSPOUT -

REFINISH;

REPLACE IF DAMAGED BEYOND REPAIR -

MATCH EXIST IF NEEDED

15-AE502

F8

TYP

2X BLOCKING (TYP)

PREFINISHED SHEET

METAL COPING

1/2" TREATED PLYWD.

CONT. CLEAT W/ SEALANT

DEFS OVER EXISTING STUCCO

WRAP ROOF MEMBRANE OVER

PARAPET / BLOCKING

1 1/2"

1'-0 1/4"

5/

8"

1/

2"

3/ 4"

VARIED FAILED

CONNECTIONS

-SEE DETAILS BELOW

EXISTING STRUCTURE

LADDER CAGE

EXISTING STUCCO

2X BLOCKING (TYP)

PREFINISHED SHEET

METAL COPING

EXIST CONCRETE ROOF DECK

FIBER CANT

STRIP

5/8" FIBERGLASS-FACED

GYPSUM COVER BOARD

3-PLY COLD-APPLIED SBS

MODIFIED BITUMEN

ROOFING SYSTEM

DEFS OVER

EXIST STUCCO

R-30 MIN. POLYISO

ROOF INSULATION

1/2" TREATED PLYWD.

CONT. CLEAT

W/ SEALANT

1/

2"

3/ 4"

1'-0 1/4"

1 1/2"

WRAP ROOF MEMBRANE OVER

PARAPET / BLOCKING

5/

8"

CONT CLEAT W/ SEALANT

3/8" DIA. SSTL HEX BOLT

NEOPRENE WASHER

LOCK WASHER

SSTL NUT

REPOSITIONED LADDER

CAGE STRAP

BENT ALUMINUM STRAP

-MATCH ALL DIMENSIONS

WITH LADDER CAGE AT

BLDG. 16

3/8" DIA. SSTL HEX BOLT

NEOPRENE WASHER

LOCK WASHER

SSTL NUT

3/4" 1 3/8"

REPOSITIONED STRAP

AL LADDER

ATTACHED AL STRAP

AL L-3X3X1/4" X 2H

SCUPPER OPENING-

MATCH EXIST OPENING

FRAME

ROOF LINE BEYOND

REFINISH/REUSE EXIST

COLLECTOR HEAD;

IF DETERMINED TO BE

DAMAGED BEYOND REPAIR,

MATCH PROFILE AND

DIMENSIONS OF EXISTING

CONDUCTOR HEAD

REFINISH/REUSE EXIST

DOWNSPOUT; IF

DETERMINED TO BE

DAMAGED BEYOND

REPAIR, MATCH EXISTING

DOWN SPOUT IN

PROFILE,

DIMENSIONS, AND

MATERIALS WITH

EXISTING

ROOFING MATERIAL TO OVERLAP

SCUPPER SHEET METAL

SEE MANUFACTURER'S

SPECIFICATIONS

LOCKED & SOLDERED

JOINT-SEAM

TYP.

TAPER INSULATION TO

SCUPPER

INSTALLED WITH BEADS

OF SEALANT

BEHIND FLASHING

INSTALLED WITH BEADS

OF SEALANT

BEHIND FLASHING

FASTENER

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMP

321 4 5 6 7 8 9 10

ARCHITECT/ENGINEER OF RECORD

Calvin rchitects, P.C.L 3705 North 200th Street

Elkhorn, Nebraska 68022

Phone: 402.291.6941 POC:

AH. INZ

6910 Pacific St #310

Omaha, NE 68106

Phone: 402.553.0234 POC:

IMEG Corp.

2882 106th Street

Des Moines, Iowa

Phone: 515.334.4303

POC:

AMI Enviromental

8802 S 135th Street

Omaha, NE 68138

Phone: 402.397.5001

POC:

BID SET

07/17/2019

Dwg. Of

C

L H

D C

\H o m e \a ta s t\

R

-2

B U

IL

D

IN

G

A lt e rn a te a ta s t.

rv t

/1

/2

:0

:4

P

M

15-AE502

ARCHITECTURAL DETAILS - ROOF

& LADDER

RENOVATE BUILDING 15

VAHCS MARION, IL

657A5-18-111

7/17/2019 AHT KRK/TJF

24 73

BID SET

INTACT CONNECTIONS

SHEARED CONNECTIONS -

REPAIR PER DETAILS

DAMAGED

LADDER CAGE

INTACT CONNECTIONS

INTACT CONNECTIONS

INTACT CONNECTIONS

USE SIMILAR

DIMENSIONS FOR

BRACKETS AT BLDG. 15

SCALE: 1 1/2" = 1'-0"

D8

PARAPET DETAIL - AT SCUPPER

SCALE: 1" = 1'-0"

A4

ROOF LADDER REPAIR DETAIL

SCALE: 1 1/2" = 1'-0"

B8

PARAPET DETAIL

NEIGHBORING

BUILDING 16

LADDER CAGE

DAMAGED

LADDER CAGE

DAMAGED

LADDER CAGE

SHEARED

CONNECTIONS -

REPAIR PER

DETAILS

DAMAGED

LADDER CAGE

SCALE: 3" = 1'-0"

C4

LADDER CAGE REPAIR DETAIL - FLAT STRAP

SCALE: 3" = 1'-0"

B4

LADDER CAGE REPAIR DETAIL-ANGLE

NEIGHBORING

BUILDING 16

LADDER CAGE

SCALE: 1 1/2" = 1'-0"

C6

ROOF - SCUPPER ELEVATION

F1

LADDER CAGE EXIST. COND-OVERALL

N.T.S. F4

EXIST LADDER CAGE - BLDG. 15

N.T.S.

C1

LADDER CAGE EXIST. COND-TOP

N.T.S.

F6

EXIST LADDER CAGE - BLDG. 16

N.T.S.

E6

EXIST LADDER CAGE - BLDG. 16

N.T.S.

E4

LADDER CAGE EXIST. COND.

N.T.S.

B6

TYP. SCUPPER - EXIST COND.

N.T.S.

EXIST OPENING FRAME/COVER -

FABRICATE NEW TO MATCH EXIST

EXIST COLLECTOR HEAD -

REPAIR/RESTORE AND REINSTALL;

IF DAMAGED BEYOND REPAIR,

REPLACE AND MATCH EXISTING

EXIST DOWNSPOUT

TO REPAIR/RESTORE/REINSTALL;

IF DAMAGED BEYOND REPAIR,

REPLACE AND MATCH EXISTING

D5

15-AE502

C4

15-AE502

B4

15-AE502

C4

15-AE502

B4

15-AE502

B4

C4

C4

15-AE502

FABRICATE AT LOCATIONS TO

MAKE SIMILAR TO BLDG. 16

SCALE: 3" = 1'-0"

F8

ROOF SCUPPER DETAIL

Revisions: Date:

EXISTING LADDER SECURITY

COVER TO REMAIN

Sheets
X-001 - COVER SHEET & INDEX OF DRAWINGS
G-001 - GENERAL NOTES, ABBREVIATIONS & SYMBOLS
G-002 - WALL TYPES & PARTITION DETAILS
15-GI101 - LIFE SAFETY & CODE REVIEW PLAN
15-GI102 - LIFE SAFETY & CODE REVIEW
15-AD101 - FLOOR PLAN - DEMOLITION
15-AD102 - REFLECTED CEILING PLAN - DEMOLITION
15-AD103 - ROOF PLANS - DEMOLITION & RENOVATION
15-AE101 - FLOOR PLAN - RENOVATION
15-AE501 - ARCHITECTURAL DETAILS
15-AE502 - ARCHITECTURAL DETAILS - ROOF & LADDER
15-AE503 - INTERIOR DETAILS
15-AE901 - INTERIOR ELEVATIONS
15-AE902 - INTERIOR ELEVATIONS
15-AC101 - REFLECTED CEILING PLAN & DETAILS - RENOVATION
15-AF101 - FINISH & SIGNAGE PLAN - RENOVATION
15-QE101 - FURNITURE & EQUIPMENT PLAN - RENOVATION
X-001 Rev 21-05-25 Sig Block.pdf
Sheets
15-AC101 - REFLECTED CEILING PLAN & DETAILS - RENOVATION
15-AD101 - FLOOR PLAN - DEMOLITION
15-AD102 - REFLECTED CEILING PLAN - DEMOLITION
15-AD103 - ROOF PLANS - DEMOLITION & RENOVATION
15-AE101 - FLOOR PLAN - RENOVATION
15-AE501 - ARCHITECTURAL DETAILS
15-AE502 - ARCHITECTURAL DETAILS - ROOF & LADDER
15-AE503 - INTERIOR DETAILS
15-AE901 - INTERIOR ELEVATIONS
15-AE902 - INTERIOR ELEVATIONS
15-AF101 - FINISH & SIGNAGE PLAN - RENOVATION
15-GI101 - LIFE SAFETY & CODE REVIEW PLAN
15-GI102 - LIFE SAFETY & CODE REVIEW
15-QE101 - FURNITURE & EQUIPMENT PLAN - RENOVATION
G-001 - GENERAL NOTES, ABBREVIATIONS & SYMBOLS
G-002 - WALL TYPES & PARTITION DETAILS
X-001 - COVER SHEET & INDEX OF DRAWINGS

File details come from the government source that posted it. Updated .