SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

SECTION A - SOLICITATION/CONTRACT FORM

The following have been added by full text:

AMENDMENT 0001

The purpose of this amendment is to update drawing 616846 Rev "W" SEPCOR referenced in Section C “Statement of Work” of this Solicitation.

SECTION C - DESCRIPTIONS AND SPECIFICATIONS

The following have been modified:

STATEMENT OF WORK

The US Navy needs to modify all the Jet Blast Deflectors (JBDs) aboard all CVN’s to support the deployment of the Joint Strike Fighter. Due to increased exhaust plume temperatures and velocities created by the F-35C Joint Strike Fighter (JSF) a hardware change to modify the JBDs saltwater cooling capacity. Cooling improvements will be created by adding Sideplate Cooled (SPC) JBD panels in locations that currently use non-SPC modules. In addition to increase the cooling capacity of SPC panels the JBD Manifolds will modify water distribution orifice configuration to stay within the limitation of ship’s seawater supply system. This contract also contains currently deployed JBD parts that may need to be replaced in order to get the JBDs up to full operating capacity.

Manufacture of SPC and NON-SPC panels shall be in accordance with the drawings listed below in the following two tables and approved Technical Data Requirements (TDRs) 16-19017 and 16-19018.

Table 1 SPC – 626145-6, -7, -8

420149
420674
514912
515646
523314
626143
MPR1222
420222
421280
514913
518309
616846
626144
MPR1223
420223
422439
514945
522571
617156
626145
420468
427429
514948
522663
617296
MPR1057
420480
514761
514969
522699
626129
MPR1221

The following drawings and revisions are provided from TDR-16-19018 for SPC panels:

626145-6, -7, -8 REVISION F ---

(CAI)

420149-5 REVISION J ---

(NONE)

420222-1 REVISION E ---

(NONE)

420223-1 REVISION E ---

(NONE)

420468-1 REVISION G ---

THRU -3

(NONE)

420480-1 REVISION G ---

(NONE)

420674-4 THRU -6 REVISION M DISREGARD “QUALITY ASSURANCE REQUIREMENT” ON DRAWING.

(NONE)

421280-1-0206REVISION B---
-1-0222

(NONE)

422439-5REVISION NREPLACE THE “PROCURING ACTIVITY TAKE NOTE” ON DRAWING WITH
(CAI)THE FOLLOWING UPDATED NOTE:
PROCURING ACTIVITY TAKE NOTE:
TO ENSURE PROCURING ACTIVITY HAS THE LATEST DRAWING REVISIONS, SPECIFICATIONS AND QUALITY ASSURANCE REQUIREMENTS, A TECH-NICAL DATA REQUIREMENTS (TDR) REQUEST IS REQUIRED PRIOR TO PROCUREMENT. THE REQUEST FOR TDR SHALL BE FORWARDED VIA EMAIL TO TDRREI@NAVY.MIL. THE TDR WILL BE PROCESSED IN A MAXIMUM OF THIRTY (30) DAYS.

427429-1 REVISION A IN NOTE 1, ASTM A269/A269M (SUPERSEDING “ASTM A269”).

(NONE)

IN NOTE 3, ASTM A967/A967M (SUPERSEDING “ASTM A967”).

514761-1 REVISION E ---

(NONE)

514912-1 REVISION J IN “ASSOCIATED DOCUMENTS” BLOCK, DISREGARD ASME B46.1.

(NONE)

DISREGARD NOTE 1, IN LIEU THEREOF THE FOLLOWING SHALL APPLY:
REMOVE BURRS AND BREAK ALL SHARP EDGES .015 MAX.
514912-1(CONT’D)DISREGARD NOTE 7, IN LIEU THEREOF THE FOLLOWING SHALL APPLY:
(NONE)WELDS SHALL BE 100% MAGNETIC PARTICLE INSPECTED IN ACCORDANCE WITH ASTM E1444/E1444M, PERFORMED BY BOTH CIRCULAR AND LONGITUDINAL METHOD. THE WET PROCESS SHALL BE USED. WELDS SHALL MEET THE CLASS 1 REQUIREMENTS OF MIL-STD-2035. BASE METAL SHALL MEET THE REQUIREMENTS OF MIL-STD-2035. THE ROOT AND FINAL PASS WELDS ARE BOTH TO BE INSPECTED.

IN TABLE 1, IN NEXT ASSEMBLY COLUMN, FOR -1 ASSEMBLY, ADD 617018 (SUPERSEDING “617953”).

514913-1 REVISION G ---

(NONE)

514945-3L/-3R REVISION R ---

(NONE)

514948-1 REVISION K ---

(NONE)

514969-3 REVISION R ---

(NONE)

515646-1, -3REVISION KIN “ASSOCIATED DOCUMENTS” BLOCK, DISREGARD ASME B46.1 AND
(NONE)ASME Y14.100.

DISREGARD NOTE 3, IN LIEU THEREOF THE FOLLOWING SHALL APPLY:

EACH FINISHED PART SHALL BE 100% PENETRANT INSPECTED IN ACCORDANCE WITH ASTM E1417/E1417M, TYPE I, METHOD A, SENSITIVITY LEVEL 2. PARTS MUST MEET THE REQUIREMENTS OF MIL-STD-2035, EXCEPT NO INDICATIONS GREATER THAN .062 INCH ARE ACCEPTABLE.

IN NOTE 5, NAWC CAGE CODE-PART NUMBER (SUPERSEDING “NAWC PART
NUMBER”).

IN NOTE 7, NAWC CAGE CODE-PART NO. AND CONTRACT NO. (SUPERSEDING “NAWC PART NO.”) AND ADD: IF PART IS SUPPLIED AS PART OF AN ASSEMBLY, IDENTIFICATION IS NOT REQUIRED.

IN NOTE 9, SAE AS8879 (SUPERSEDING “MIL-S-8879”).

518309-17, -18 REVISION AE ---

(CAI)

522571-1 REVISION E IN “ASSOCIATED DOCUMENTS” BLOCK, DISREGARD ASME Y14.100.

(NONE)

IN NOTE 5, ADD: INCLUDING NAWC CAGE CODE-PART NUMBER AND CONTRACT NUMBER.

522663-1-250, -1-312,REVISION AADD AS NOTE 6: SURFACE ROUGHNESS IN MICRO INCHES SHALL BE IN-
-1-406, -1-438,-1-500,TERPRETED IN ACCORDANCE WITH ASME B46.1.

-1-781, -1-688, -1-469, -1-375, -1-531, -1-1000

(NONE)

522699-7REVISION CDISREGARD NOTE 5, IN LIEU THEREOF THE FOLLOWING SHALL APPLY:
(NONE)FOR .750 OUTSIDE DIAMETER AND LARGER, ETCH NAWC CAGE CODE-PART NUMBER AND CONTRACT NUMBER IN LOCATION INDICATED IN ACCORDANCE WITH MIL-STD-130. FOR OTHERS BAG AND TAG WITH SAME INFORMATION. IF PART IS SUPPLIED AS PART OF AN ASSEMBLY, IDENTIFICATION IS NOT REQUIRED.

ADD AS NOTE 8: SURFACE ROUGHNESS IN MICRO INCHES SHALL BE INTERPRETED IN ACCORDANCE WITH ASME B46.1.

523314-1REVISION BREALIGN NUMBERS COLUMN IN NOTE FIELD 1, THROUGH 4. AND REMOVE
(NONE)5. FROM DRAWING.

616846-44, 144 REVISION W ---

(NONE)

617156-6REVISION YADD AS NOTE 14: SURFACE ROUGHNESS IN MICRO INCHES SHALL BE IN-
(CAI)TERPRETED IN ACCORDANCE WITH ASME B46.1.
REPLACE THE “PROCURING ACTIVITY TAKE NOTE” ON DRAWING WITH
THE FOLLOWING UPDATED NOTE:
PROCURING ACTIVITY TAKE NOTE:
TO ENSURE PROCURING ACTIVITY HAS THE LATEST DRAWING REVISIONS, SPECIFICATIONS AND QUALITY ASSURANCE REQUIREMENTS, A TECH-NICAL DATA REQUIREMENTS (TDR) REQUEST IS REQUIRED PRIOR TO PROCUREMENT. THE REQUEST FOR TDR SHALL BE FORWARDED VIA EMAIL TO TDRREI@NAVY.MIL. THE TDR WILL BE PROCESSED IN A MAXIMUM OF THIRTY (30) DAYS.

617296-1, -6 REVISION H _ _ _ _ _ _ _

(NONE)

626129-5, -6 REVISION R ---

(CAI)

626143-1REVISION FREPLACE THE “PROCURING ACTIVITY TAKE NOTE” ON DRAWING WITH
(CAI)THE FOLLOWING UPDATED NOTE:
PROCURING ACTIVITY TAKE NOTE:
TO ENSURE PROCURING ACTIVITY HAS THE LATEST DRAWING REVISIONS, SPECIFICATIONS AND QUALITY ASSURANCE REQUIREMENTS, A TECH-NICAL DATA REQUIREMENTS (TDR) REQUEST IS REQUIRED PRIOR TO PROCUREMENT. THE REQUEST FOR TDR SHALL BE FORWARDED VIA EMAIL TO TDRREI@NAVY.MIL. THE TDR WILL BE PROCESSED IN A MAXIMUM OF THIRTY (30) DAYS.

626144-1, -2 REVISION C IN NOTE 2, ADD IN ACCORDANCE WITH MIL-STD-130. IN ZONE C10, DIAMETER OF COUNTERBORE SHOULD BE 1.25 INCH VICE 1.00 INCH.

(NONE)

MILITARY STANDARDS:

MS51831 REVISION G _ _ _ _ _ _ _

MS51832 REVISION D _ _ _ _ _ _ _

MS51835 REVISION B _ _ _ _ _ _ _

NATIONAL AEROSPACE STANDARDS:

NAS1149 REVISION 6 _ _ _ _ _ _ _

NAS3106 REVISION 4 _ _ _ _ _ _ _

NASM970 REVISION 2 _ _ _ _ _ _ _

NASM17830 REVISION 1 _ _ _ _ _ _ _

NASM20995 REVISION 1 _ _ _ _ _ _ _

NASM21045 REVISION 3 _ _ _ _ _ _ _

NASM21250 REVISION 2 _ _ _ _ _ _ _

NASM33540 REVISION 3 _ _ _ _ _ _ _

NASM39086 REVISION 1 _ _ _ _ _ _ _

NASM51029 REVISION 2 _ _ _ _ _ _ _

NASM51975 REVISION 4 _ _ _ _ _ _ _

NOTE 1:WHERE NAVAL AIR ENGINEERING CENTER MATERIAL AND PROCESS
REQUIREMENTS (MPR’S) ARE REFERENCED, THE MPR’S SHALL PREVAIL OVER ANY OTHER SPECIFICATIONS CITED. THE FOLLOWING IS A LIST OF MPR’S THAT ARE REQUIRED AND APPLY:

MPR 1057 REVISION A

MPR 1221 REVISION R

WHERE MPR 1221 IS REFERENCED, THE FOLLOWING CHANGES SHALL
APPLY:
SHEET 1:
PARA. 2:
MIL-DTL-5541 (SUPERSEDING “MIL-C-5541”).
MIL-PRF-23236 (SUPERSEDING “MIL-P-23236”).
AND IN SPECIFICATION TITLE, COATING SYSTEMS FOR SHIP STRUCTURES (SUPERSEDING “PAINT COATING SYSTEMS, FUEL AND SALT WATER BALLAST TANKS”).
FOR MIL-PRF-24635, IN SPECIFICATION TITLE, COATING SYSTEMS WEATHER RESISTANT EXTERIOR USE (SUPERSEDING “ENAMEL, SILICONE ALKYD COPOLYMER”).
MIL-DTL-53022 (SUPERSEDING “MIL-P-53022”).
SHEET 2:
PARA. 3.6.3
MIL-DTL-5541 (SUPERSEDING “MIL-C-5541”).
SHEET 3:
PARA. 3.7:
MIL-DTL-53022 (SUPERSEDING “MIL-P-53022”).
NOTE 1:SHEET 5 THROUGH SHEET 11:
(CONT’D)TABLE: EPOXY PAINT SYSTEM
MIL-DTL-53022 (SUPERSEDING “MIL-P-53022”).
SHEET 6:
FOR FINISH NUMBER 30, MIL-PRF-23236 (SUPERSEDING “MIL-P-23236, TYPE I, CLASS 1”).

MPR 1222 REVISION NONE

WHERE MPR 1222 IS REFERENCED THE FOLLOWING CHANGES SHALL APPLY:

SHEET 2:
PARA. 5.A:
TT-P-28 (SUPERSEDING “METCOSEAL SA”) AND DISREGARD “THINNER SHALL BE METCOSEAL ST-1 OR EQUIVALENT”.
PARA. 5.b:
DISREGARD “BY THOROUGHLY WASHING WITH ST-1 THINNER”.

MPR 1223 REVISION B

WHERE MPR 1223 IS REFERENCED, THE FOLLOWING CHANGES SHALL APPLY:

SHEET 1:
PARA. 3.1:
A-A-59316, TYPE IV, GRADE A (SUPERSEDING “MIL-A-21380, TYPE IV”).
PARA. 3.2:
SAE J1993 (SUPERSEDING “MIL-S-851”).
PARA. 3.3:
A-A-59316, TYPE I, GRADE A (SUPERSEDING “MIL-A-21380, TYPE I”).

NOTE 2: WHERE NAVSEA TECHNICAL PUBLICATIONS ARE LISTED ON DRAWINGS, THE FOLLOWING SHALL APPLY:

FOR NAVSEA T9074-AS-GIB-010/271 “REQUIREMENTS FOR NON DESTRUCTIVE TESTING METHODS”, IS HEREBY MODIFIED TO ADD THE FOLLOWING NOTE:

PARA. 1.5.1 “ AUTHORIZED REPRESENTATIVE” IS HEREBY MODIFIED TO ADD THE FOLLOWING PARAGRAPH: IN ADDITION TO ESTABLISHED NAVAIR TECHNICAL WARRANT HOLDERS, NAVAIR 4.3.4 IS AN AUTHORIZED REPRESENTATIVE SPECIFICALLY AUTHORIZED TO APPROVE EQUIPMENT, MATERIAL OR PROCEDURES WITHIN THE SCOPE OF THIS DOCUMENT FOR THIS ITEM.

FOR NAVSEA S9074-AR-GIB-010/278 “REQUIREMENTS FOR FABRICATION WELDING AND INSPECTION AND CASTING INSPECTION AND REPAIR FOR MACHINERY, PIPING AND PRESSURE VESSELS”, IS HEREBY MODIFIED TO ADD THE FOLLOWING NOTE:

PARA. 3.3.1.4: “AUTHORIZED REPRESENTATIVE” IS HEREBY MODIFIED TO ADD THE FOLLOWING PARAGRAPH: IN ADDITION TO ESTABLISHED NAVAIR TECHNICAL WARRANT HOLDERS, NAVAIR 4.3.4 IS AN AUTHORIZED REPRESENTATIVE SPECIFICALLY AUTHORIZED TO APPROVE EQUIPMENT, MATERIAL OR PROCEDURES WITHIN THE SCOPE OF THIS DOCUMENT FOR THIS ITEM.

NOTE 3: WHERE REFERENCED ON DRAWINGS, THE FOLLOWING NOTES SHALL APPLY:

ASME Y14.100 (SUPERSEDING “MIL-STD-100”).

NOTE 4: UNLESS OTHERWISE SPECIFIED, IDENTIFY IN ACCORDANCE WITH MIL-STD-130, INCLUDING NAWC CAGE CODE-PART NUMBER AND CONTRACT NUMBER.

NOTE 5:SECTION 326 OF THE 1993 DEFENSE AUTHORIZATION ACT PLACES
RESTRICTIONS ON THE USE OF CLASS I OZONE DEPLETING SUBSTANCES (ODS). UNTIL SUCH TIME AS THESE CLASS I ODS'S ARE ELIMINATED FROM MILITARY DRAWINGS AND SPECIFICATIONS (INCLUDING SECOND TIER, I.E., THOSE SPECIFICATIONS LISTED IN THE SPECIFICATIONS LISTED ON THE DRAWINGS), THE FOLLOWING SHALL APPLY:

1. THE CONTRACTOR SHALL USE A GOVERNMENT APPROVED NON-OZONE DEPLETING SUBSTANCE.

2. IF A GOVERNMENT APPROVED NON-OZONE DEPLETING SUBSTANCE IS UNKNOWN/UNAVAILABLE, THE CONTRACTOR SHALL CONTACT 4.3.4.1 AT NAWCAD LAKEHURST FOR AN ACCEPTABLE SUBSTITUTE, AN ALTERNATE PROCESS OR A WAIVER OF THE REQUIREMENT.

Table 2 NON-SPC – 617018-24

420149
420480
514761
514948
522571
617018
MPR1057
420222
420674
514912
514969
522663
617156
MPR1221
420223
421280
514913
515646
522699
617296
MPR1222
420468
422439
514945
518309
616846
626129
MPR1223

The following drawings and revisions are provided from TDR-16-19017 for NON-SPC panels:

617018-24 REVISION AH ---

(CAI)

420149-5 REVISION J ---

(NONE)

420222-1 REVISION E ---

(NONE)

420223-1 REVISION E ---

(NONE)

420468-1 REVISION G ---

-2 -3

(NONE)

420480-1 REVISION G ---

(NONE)

420674-4 REVISION M DISREGARD “QUALITY ASSURANCE REQUIREMENTS” NOTE ON DRAWING.

-5

(NONE)

421280-1-0206 REVISION B ---

-1-0222

(NONE)

422439-5 REVISION N _ _ _ _ _ _ _

(CAI)

514761-1 REVISION E ---

(NONE)

514912-1 REVISION J IN “ASSOCIATED DOCUMENTS” BLOCK, DISREGARD ASME B46.1.

(NONE)

DISREGARD NOTE 1, IN LIEU THEREOF THE FOLLOWING SHALL APPLY: REMOVE BURRS AND BREAK ALL SHARP EDGES .015 MAX.

DISREGARD NOTE 7, IN LIEU THEREOF THE FOLLOWING SHALL APPLY: WELDS SHALL BE 100% MAGNETIC PARTICLE INSPECTED IN ACCORDANCE WITH ASTM E1444/E1444M PERFORMED BY BOTH CIRCULAR AND LONGITUDINAL METHOD. THE WET PROCESS SHALL BE USED. WELDS SHALL MEET THE CLASS 1 REQUIREMENTS OF MIL-STD-2035. BASE METAL SHALL MEET THE REQUIREMENTS OF MIL-STD-2035. THE ROOT AND FINAL PASS WELDS ARE BOTH TO BE INSPECTED.

IN TABLE 1, IN NEXT ASSEMBLY COLUMN, FOR -1 ASSEMBLY, ADD 617018 (SUPERSEDING “617953”).

514913-1 REVISION G ---

(NONE)

514945-3L/R REVISION R ---

(NONE)

514948-1 REVISION K ---

(NONE)

514969-3 REVISION R ---

(NONE)

515646-1REVISION KIN “ASSOCIATED DOCUMENTS” BLOCK, DISREGARD ASME B46.1 AND
(NONE)ASME Y14.100.

DISREGARD NOTE 3, IN LIEU THEREOF THE FOLLOWING SHALL APPLY:

EACH FINISHED PART SHALL BE 100% PENETRANT INSPECTED IN AC-CORDANCE WITH ASTM E1417/E1417M TYPE I, METHOD A, SENSITIVITY LEVEL 2. PARTS MUST MEET THE REQUIREMENTS OF MIL-STD-2035, EXCEPT NO INDICATIONS GREATER THAN .062 INCH ARE ACCEPTABLE.

IN NOTE 5, NAWC CAGE CODE-PART NUMBER (SUPERSEDING “NAWC PART NUMBER”).

IN NOTE 7, NAWC CAGE CODE-PART NO. AND CONTRACT NO. (SUPERSEDING “NAWC PART NO.”) AND ADD: IF PART IS SUPPLIED AS PART OF AN ASSEMBLY, IDENTIFICATION IS NOT REQUIRED.

IN NOTE 9, SAE AS8879 (SUPERSEDING “MIL-S-8879”).

518309-17 REVISION AE ---

(CAI)

522571-1 REVISION E IN “ASSOCIATED DOCUMENTS” BLOCK, DISREGARD ASME Y14.100.

((NONE)

IN NOTE 5, ADD: INCLUDING NAWC CAGE CODE-PART NUMBER AND CONTRACT NUMBER.

522663-1-312REVISION AADD AS NOTE 6: SURFACE ROUGHNESS IN MICRO INCHES SHALL BE
-1-250INTERPRETED IN ACCORDANCE WITH ASME B46.1.

(NONE)

522699-7REVISION CDISREGARD NOTE 5, IN LIEU THEREOF THE FOLLOWING SHALL APPLY:
(NONE)FOR .750 OUTSIDE DIAMETER AND LARGER, ETCH NAWC CAGE CODE-PART NUMBER AND CONTRACT NUMBER IN LOCATION INDICATED IN ACCORDANCE WITH MIL-STD-130. FOR OTHERS BAG AND TAG WITH SAME INFORMATION. IF PART IS SUPPLIED AS PART OF AN ASSEMBLY, IDENTIFICATION IS NOT REQUIRED.
ADD AS NOTE 8: SURFACE ROUGHNESS IN MICRO INCHES SHALL BE
INTERPRETED IN ACCORDANCE WITH ASME B46.1.

616846-144 REVISION W ---

(NONE)

617156-6REVISION YADD AS NOTE 14: SURFACE ROUGHNESS IN MICRO INCHES SHALL BE IN-
(CAI)TERPRETED IN ACCORDANCE WITH ASME B46.1.
REPLACE THE “PROCURING ACTIVITY TAKE NOTE” ON DRAWING WITH
THE FOLLOWING UPDATED NOTE:
PROCURING ACTIVITY TAKE NOTE:
TO ENSURE PROCURING ACTIVITY HAS THE LATEST DRAWING REVISIONS, SPECIFICATIONS AND QUALITY ASSURANCE REQUIREMENTS, A TECH-NICAL DATA REQUIREMENTS (TDR) REQUEST IS REQUIRED PRIOR TO PROCUREMENT. THE REQUEST FOR TDR SHALL BE FORWARDED VIA EMAIL TO TDRREI@NAVY.MIL. THE TDR WILL BE PROCESSED IN A MAXIMUM OF THIRTY (30) DAYS.

617296-1 REVISION H

-6

(NONE)

626129-1 REVISION R _ _ _ _ _ _ _

-2

(CAI)

MILITARY STANDARDS:

MS51831 REVISION G _ _ _ _ _ _ _

MS51832 REVISION D _ _ _ _ _ _ _

MS51835 REVISION B _ _ _ _ _ _ _

NATIONAL AEROSPACE STANDARDS:

NAS1149 REVISION 6 _ _ _ _ _ _ _

NAS1351 REVISION 11 _ _ _ _ _ _ _

NAS3106 REVISION 4 _ _ _ _ _ _ _

NASM970 REVISION 2 _ _ _ _ _ _ _

NASM15795 REVISION 2 _ _ _ _ _ _ _

NASM17830 REVISION 1 _ _ _ _ _ _ _

NASM20995 REVISION 1 _ _ _ _ _ _ _

NASM21045 REVISION 3 _ _ _ _ _ _ _

NASM21250 REVISION 2 _ _ _ _ _ _ _

NASM33540 REVISION 2 _ _ _ _ _ _ _

NASM39086 REVISION 1 _ _ _ _ _ _ _

NASM51029 REVISION 2 _ _ _ _ _ _ _

NASM51975 REVISION 4 _ _ _ _ _ _ _

NOTE 1:WHERE NAVAL AIR ENGINEERING CENTER MATERIAL AND PROCESS
REQUIREMENTS (MPR'S) ARE REFERENCED, THE MPR'S SHALL PREVAIL OVER ANY OTHER SPECIFICATIONS CITED. THE FOLLOWING IS A LIST OF MPR'S THAT ARE REQUIRED AND APPLY:

MPR 1057 REVISON A

MPR 1221 REVISON R

WHERE MPR 1221 IS REFERENCED, THE FOLLOWING CHANGES SHALL
APPLY:
SHEET 1:
PARA. 2:
MIL-DTL-5541 (SUPERSEDING “MIL-C-5541”).
MIL-PRF-23236 (SUPERSEDING “MIL-P-23236”).
AND IN SPECIFICATION TITLE, COATING SYSTEMS FOR SHIP STRUCTURES (SUPERSEDING “PAINT COATING SYSTEMS, FUEL AND SALT WATER BALLAST TANKS”).
NOTE 1FOR MIL-PRF-24635, IN SPECIFICATION TITLE, COATING SYSTEMS
(CONT’D)WEATHER RESISTANT EXTERIOR USE (SUPERSEDING “ENAMEL, SILICONE ALKYD COPOLYMER”).
MIL-DTL-53022 (SUPERSEDING “MIL-P-53022”).
SHEET 2:
PARA. 3.6.3
MIL-DTL-5541 (SUPERSEDING "MIL-C-5541").
SHEET 3:
PARA. 3.7:
MIL-DTL-53022 (SUPERSEDING “MIL-P-53022”).
SHEET 5 THROUGH SHEET 11:
TABLE: EPOXY PAINT SYSTEM
MIL-DTL-53022 (SUPERSEDING “MIL-P-53022”).
SHEET 6:
FOR FINISH NUMBER 30, MIL-PRF-23236 (SUPERSEDING “MIL-P-23236, TYPE I, CLASS 1”).

MPR 1222 REVISION NONE

WHERE MPR 1222 IS REFERENCE THE FOLLOWING CHANGES SHALL APPY

SHEET 2:
PARA. 5.a:
TT-P-28 (SUPERSEDING "METCOSEAL SA") AND DISREGARD "THINNER SHALL BE METCOSEAL ST-1 OR EQUIVALENT”.
PARA. 5.b:
DISREGARD “BY THOROUGHLY WASHING WITH ST-1 THINNER”.

MPR 1223 REVISION B

WHERE MPR 1223 IS REFERENCED, THE FOLLOWING CHANGES SHALL
APPLY:
SHEET 1:
PARA. 3.1:
A-A-59316, TYPE IV, GRADE A (SUPERSEDING "MIL-A-21380, TYPE IV").
PARA. 3.2:
SAE J1993 (SUPERSEDING "MIL-S-851").
PARA. 3.3:
A-A-59316, TYPE I, GRADE A (SUPERSEDING "MIL-A-21380, TYPE I").

NOTE 2: WHERE NAVSEA TECHNICAL PUBLICATIONS ARE LISTED ON DRAWINGS, THE FOLLOWING SHALL APPLY:

FOR NAVSEA T9074-AS-GIB-010/271 “REQUIREMENTS FOR NON DESTRUCTIVE TESTING METHODS”, IS HEREBY MODIFIED TO ADD THE FOLLOWING NOTE:

NOTE 2:PARA. 1.5.1 “AUTHORIZED REPRESENTATIVE” IS HEREBY MODIFIED TO
(CONT’D)ADD THE FOLLOWING PARAGRAPH: IN ADDITION TO ESTABLISHED NAVAIR TECHNICAL WARRANT HOLDERS, NAVAIR 4.3.4 IS AN AUTHORIZED REPRESENTATIVE SPECIFICALLY AUTHORIZED TO APPROVE EQUIPMENT, MATERIAL OR PROCEDURES WITHIN THE SCOPE OF THIS DOCUMENT FOR THIS ITEM.

FOR NAVSEA S9074-AR-GIB-010/278 “REQUIREMENTS FOR FABRICATION WELDING AND INSPECTION AND CASTING INSPECTION AND REPAIR FOR MACHINERY, PIPING AND PRESSURE VESSELS”, IS HEREBY MODIFIED TO ADD THE FOLLOWING NOTE:

PARA. 3.3.1.4: “AUTHORIZED REPRESENTATIVE” IS HEREBY MODIFIED TO ADD THE FOLLOWING PARAGRAPH: IN ADDITION TO ESTABLISHED NAVAIR TECHNICAL WARRANT HOLDERS, NAVAIR 4.3.4 IS AN AUTHORIZED REPRESENTATIVE SPECIFICALLY AUTHORIZED TO APPROVE EQUIPMENT, MATERIAL OR PROCEDURES WITHIN THE SCOPE OF THIS DOCUMENT FOR THIS ITEM.

NOTE 3:WHERE REFERENCED ON DRAWINGS, THE FOLLOWING NOTES SHALL
APPLY:

ASME Y14.100 (SUPERSEDING “MIL-STD-100”).

NOTE 4: UNLESS OTHERWISE SPECIFIED, IDENTIFY IN ACCORDANCE WITH MIL-STD-130, INCLUDING NAWC CAGE CODE-PART NUMBER AND CONTRACT NUMBER.

NOTE 5:SECTION 326 OF THE 1993 DEFENSE AUTHORIZATION ACT PLACES
RESTRICTIONS ON THE USE OF CLASS I OZONE DEPLETING SUBSTANCES (ODS). UNTIL SUCH TIME AS THESE CLASS I ODS'S ARE ELIMINATED FROM MILITARY DRAWINGS AND SPECIFICATIONS (INCLUDING SECOND TIER, I.E., THOSE SPECIFICATIONS LISTED IN THE SPECIFICATIONS LISTED ON THE DRAWINGS), THE FOLLOWING SHALL APPLY:

1. THE CONTRACTOR SHALL USE A GOVERNMENT APPROVED NON-OZONE DEPLETING SUBSTANCE.

2. IF A GOVERNMENT APPROVED NON-OZONE DEPLETING SUBSTANCE IS UNKNOWN/UNAVAILABLE, THE CONTRACTOR SHALL CONTACT 4.3.4.1 AT NAWCAD LAKEHURST FOR AN ACCEPTABLE SUBSTITUTE, AN ALTERNATE PROCESS OR A WAIVER OF THE REQUIREMENT.

(End of Summary of Changes) image1.wmf