J_-_2_Category_A_Item_Revised.xlsx
XLSX spreadsheet 30 KB Posted
- Attached to
- USNS GRASP ROH/DD Federal contract opportunity
- Solicitation number
- N3220518R4555
About this file
J-2
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment.docx | DOCX document | |
| Q&A__6_Answer.docx | DOCX document | |
| Extension_Request_Answer.docx | DOCX document | |
| QA__5_Answers.docx | DOCX document | |
| J-3_Category_B_Item_Revised.xlsx | XLSX spreadsheet | |
| Amendment_3.docx | DOCX document | |
| QA__4_Answers.docx | DOCX document | |
| Amendment_0002.docx | DOCX document | |
| Q&A__2_Answer.rtf | RTF text file | |
| QA__3_Answer.doc.rtf | RTF text file | |
| Q&A__1_PPE_Answer.rtf | RTF text file | |
| Amendment0001.docx | DOCX document | |
| J-Attachments.zip | ZIP file | |
| J&A_Redacted.pdf | ||
| N3220518R4555_SOLICITATION.docx | DOCX document | |
| SYNOPSIS_N3220518R4555.docx | DOCX document |
Show all 16
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Cat A Items
| CATEGORY “A” ITEMS | ||||||||||||
| GENERAL REQUIREMENT | PRIME Contractor | SUB Contractor | Govt Mandated Tech Rep / Sub | OTHER COSTS | TOTAL PRICE | |||||||
| ITEM NO. | TITLE CAT A ITEM | PRIME L/H | LABOR PRICE | MATERIAL PRICE | SUB L/H | LABOR PRICE | MATERIAL PRICE | Price | TOTAL LABOR HOURS | TOTAL MATERIAL | ||
| CATEGORY "A" | ||||||||||||
| 000 | GENERAL REQUIREMENTS | |||||||||||
| 001 | Intent, Scope, General Conditions and Definitions | NSP | ||||||||||
| 002 | Technical Representative Rev 08Nov17 | NSP | ||||||||||
| 003 | Approach Berth and Moorings Rev 08Nov17 | NSP | ||||||||||
| 004 | Testing and Quality Assurance Rev 08Nov17 | NSP | ||||||||||
| 005 | Electrical Safety Procedure Requirements | NSP | ||||||||||
| 006 | Heavy Weather Plan | NSP | ||||||||||
| 007 | Cold Weather Plan | NSP | ||||||||||
| 024 | Physical Security at Private Contractor's Facility | NSP | ||||||||||
| 010 | Furnish Office for OMT Rev May16 | - 0 | $ - 0 | $0 | ||||||||
| 011 | Furnish General Services | - 0 | $ - 0 | $0 | ||||||||
| 012 | Telephone Services | - 0 | $ - 0 | $0 | ||||||||
| 013 | Project Planning and Production Status Monitoring | - 0 | $ - 0 | $0 | ||||||||
| 014 | Weight and Moment Report | - 0 | $ - 0 | $0 | ||||||||
| 015 | Integrated Logistics and GFM Support Requirements | - 0 | $ - 0 | $0 | ||||||||
| 016 | Fire Protection and Ship's Safety Program Rev 28Se | - 0 | $ - 0 | $0 | ||||||||
| 017 | Handling Ship Stores | - 0 | $ - 0 | $0 | ||||||||
| 018 | Delivery and Redelivery, REV MAY16 | - 0 | $ - 0 | $0 | ||||||||
| 019 | Shipboard Access Rev Aug15 | - 0 | $ - 0 | $0 | ||||||||
| 020 | Gas Free Certificates | - 0 | $ - 0 | $0 | ||||||||
| 021 | Tank Inspection and Gas Free | - 0 | $ - 0 | $0 | ||||||||
| 022 | Machinery Space Turn-Over,Dock Trials and Sea Tria | - 0 | $ - 0 | $0 | ||||||||
| 023 | Hazardous Waste Disposal Rev May16 | - 0 | $ - 0 | $0 | ||||||||
| 100 | HULL STRUCTURES | |||||||||||
| 101 | Ballast Tank Survey and Repair | - 0 | $ - 0 | $0 | ||||||||
| 102 | AMR & FGR Preservation | - 0 | $ - 0 | $0 | ||||||||
| 103 | CHT Tank Preservation and System Maintenance | - 0 | $ - 0 | $0 | ||||||||
| 104 | Potable Water Tank Repair and Preservation | - 0 | $ - 0 | $0 | ||||||||
| 105 | WTD and Scuttle Renewal | - 0 | $ - 0 | $0 | ||||||||
| 106 | Steel Renewal | - 0 | $ - 0 | $0 | ||||||||
| 107 | Main Mast Steel Renewal | - 0 | $ - 0 | $0 | ||||||||
| 200 | MAIN PROPULSION | |||||||||||
| 201 | Engine and Generator Repairs | - 0 | $ - 0 | $0 | ||||||||
| 202 | Main Reduction Gear Thurst Bearing Maintenance | - 0 | $ - 0 | $0 | ||||||||
| 203 | Rebuild CPP Pump | - 0 | $ - 0 | $0 | ||||||||
| 300 | ELECTRICAL | |||||||||||
| 301 | Tank Level Indicator Repair and Calibration | - 0 | $ - 0 | $0 | ||||||||
| 302 | Automation System Service and Repair | - 0 | $ - 0 | $0 | ||||||||
| 303 | Generator Cleaning (2SGA) | - 0 | $ - 0 | $0 | ||||||||
| 304 | MCT Installation and Grooming | - 0 | $ - 0 | $0 | ||||||||
| 305 | Switchboard Cleaning | - 0 | $ - 0 | $0 | ||||||||
| 306 | Circuit Breaker Inspection and Servicing | - 0 | $ - 0 | $0 | ||||||||
| 400 | COMMUNICATION AND NAVIGATION | |||||||||||
| 401 | Navigational Radar Annual Grooming | - 0 | $ - 0 | $0 | ||||||||
| 402 | Gyro System Maintenance | - 0 | $ - 0 | $0 | ||||||||
| 403 | ECDIS Annual Servicing | - 0 | $ - 0 | $0 | ||||||||
| 404 | SVDR Replacement | - 0 | $ - 0 | $0 | ||||||||
| 405 | Radio Communications Equipment Annual Recertification | - 0 | $ - 0 | $0 | ||||||||
| 406 | DTS Servicing | - 0 | $ - 0 | $0 | ||||||||
| 407 | Communications Preventative Maintenance | - 0 | $ - 0 | $0 | ||||||||
| 408 | Wind Bird Calibration | - 0 | $ - 0 | $0 | ||||||||
| 500 | AUXILIARY MACHINERY | |||||||||||
| 501 | 40 Ton Boom Maintenance and Testing | - 0 | $ - 0 | $0 | ||||||||
| 502 | Appleton Crane Inspection and Repair | - 0 | $ - 0 | $0 | ||||||||
| 503 | RHIB Davit Overhaul | - 0 | $ - 0 | $0 | ||||||||
| 505 | Firefighting System Certification | - 0 | $ - 0 | $0 | ||||||||
| 506 | Work Boat Davit Repair | - 0 | $ - 0 | $0 | ||||||||
| 507 | Piping Renewal | - 0 | $ - 0 | $0 | ||||||||
| 508 | Replace 1 & 3 AUX Fire Pumps | - 0 | $ - 0 | $0 | ||||||||
| 509 | Potable Water Manifold Replacement | - 0 | $ - 0 | $0 | ||||||||
| 510 | No. 3 AC & No. 2 Refrigeration Plant Servicing | - 0 | $ - 0 | $0 | ||||||||
| 511 | Norman Pin Replacement | - 0 | $ - 0 | $0 | ||||||||
| 512 | OWS and Oil Content Monitor Annual | - 0 | $ - 0 | $0 | ||||||||
| 600 | HABITABILITY | |||||||||||
| 601 | RHIB Service and Repairs | - 0 | $ - 0 | $0 | ||||||||
| 602 | Deck Repairs/HAB Maintenance | - 0 | $ - 0 | $0 | ||||||||
| 603 | Liferaft Inspection | - 0 | $ - 0 | $0 | ||||||||
| 605 | SCBA Annual Recertification | - 0 | $ - 0 | $0 | ||||||||
| 800 | HEATING, VENTILATION, AND AIR CONDITIONING | |||||||||||
| 802 | Vent Plenum Preservation | - 0 | $ - 0 | $0 | ||||||||
| 803 | Ventilation Renewal | - 0 | $ - 0 | $0 | ||||||||
| 804 | Radio Rom Stand Alne A/C | - 0 | $ - 0 | $0 | ||||||||
| 900 | DRY DOCKING | |||||||||||
| 901 | Dry Docking and Undocking | - 0 | $ - 0 | $0 | ||||||||
| 902 | Propulsion Shaft Repairs | - 0 | $ - 0 | $0 | ||||||||
| 903 | Bow Thruster Overhaul | - 0 | $ - 0 | $0 | ||||||||
| 904 | Rudder Inspection | - 0 | $ - 0 | $0 | ||||||||
| 905 | UT Gauging | - 0 | $ - 0 | $0 | ||||||||
| 906 | Seachest Grating Removal and Anode Replacement | - 0 | $ - 0 | $0 | ||||||||
| 907 | Cathodic Protection System | - 0 | $ - 0 | $0 | ||||||||
| 908 | Underwater Hull Blast and Coat | - 0 | $ - 0 | $0 | ||||||||
| 909 | Propulsion System Inspection and Maintenance | - 0 | $ - 0 | $0 | ||||||||
| 910 | Underwater Shell Plating Renewal | - 0 | $ - 0 | $0 | ||||||||
| 911 | Shaft Seal Refurbishment | - 0 | $ - 0 | $0 | ||||||||
| TOTAL CAT "A" | $0.00 |
| USNS MERCY | CONTRACTOR PRICE BREAKDOWN |
| &"Arial,Bold"CATEGORY "A" ITEMS | N3220518R4551 |
ATTACHMENT J-2
File details come from the government source that posted it.