Attachment5_Referenced_Documents.pdf
PDF 14 MB Posted
- Attached to
- Virginia-Class Hub Scoop Bar Fabrication
- Solicitation number
- N00167-19-R-0007
About this file
Referenced Documents
View the file
Other files
| File | Type | Posted |
|---|---|---|
| ExhibitARev1_CDRLs-A001-A007.pdf | ||
| N0016719R0007-0003.pdf | ||
| N0016719R0007-0003.pdf | ||
| ExhibitARev1_CDRLs-A001-A007.pdf | ||
| RFI_Responses.pdf | ||
| Attachment6_SCOOPVAL_Information.pdf | ||
| N0016719R0007-0002.pdf | ||
| N0016719R0007-0001.pdf | ||
| Attachment2_DD254.pdf | ||
| N0016719R0007.pdf | ||
| Attachment3_Past_Perform_Questionnaire.doc | DOC document | |
| Attachment4_Previous_Contracting_Efforts.doc | DOC document | |
| ExhibitA_CDRLs-A001-A007.pdf |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
For the best experience, open this PDF portfolio in
Acrobat X or Adobe Reader X, or later.
Get Adobe Reader Now!
http://www.adobe.com/go/reader
A 53711 245 8627737 D
SIZE CAGE CODE ESWBS NAVSEA DRAWING NO REV.
DEPARTMENT OF THE NAVY
NAVAL SEA SYSTEMS COMMAND
WASHINGTON NAVY YARD, D.C. 20376-5160
NAVY PROPULSOR SAND CAST NICKEL-
ALUMINUM-BRONZE SPECIFICATION
NORFOLK NAVAL SHIPYARD DET.
NAVAL FOUNDRY AND
PROPELLER CENTER
PHILADELPHIA, PA 19112
PREPARED
CHECKED
APPROVED FOR NAVSEA 05P3
SCALE: FULL SHEET 1 OF 8
K. JONES 1/27/15
N. BIRD 1/27/15
C. MADDEN 1/28/15
REVISIONS
SHEET REV DESCRIPTION DATE
APPROVED
A
CLARIFIED WELD PROCEDURE
EQUIVALENCY IN NOTE 401.
CLARIFIED MACHINE GOUGE WELD
CATEGORY IN NOTE 406.
CHANGED LOT TO APPLICABLE HEAT
IN NOTE 601
C. MADDEN
2/12/2016
6-7
B
UPDATED NOTE 406 TO CLARIFY
ABOUT SHIPYARDS
CLARIFIED NOTE 601
ADDED SUPPLEMENTAL
REQUIREMENTS
7/10/2017
3-4 C
UPDATED NOTE 302 MECHANICAL
REQUIREMENTS
UPDATED NOTE 303 REQUIREMENT,
FIGURES AND DIMENSIONS
11/02/2017
4-5
D
UPDATED NOTE 402 BASE METAL
REQUIREMENT AND ADDED NOTES
305, 403-405.
ADDED S4 & S5.
SEE DIGITAL
SIGNATURE
DIGITAL APPROVAL SIGNATURE
DISTRIBUTION STATEMENT A:
APPROVED FOR PUBLIC RELEASE. DISTRIBUTION IS UNLIMITED.
SCALE: FULL SHEET 2 OF 8
GENERAL NOTES
101. THE PURPOSE OF THIS DRAWING IS TO ESTABLISH REQUIREMENTS FOR NICKEL
ALUMINUM BRONZE SAND CASTINGS MADE OF UNS NO. C95800 ALLOY FOR USE IN
NAVY PROPULSOR APPLICATIONS. CASTINGS SHALL BE AS-CAST WITH NO TEMPER
ANNEAL. WELD REPAIRS SHALL ALSO NOT REQUIRE TEMPER ANNEAL.
102. MATERIAL FURNISHED UNDER THIS SPECIFICATION SHALL CONFORM TO THE
APPLICABLE REQUIREMENTS OF SECTIONS 9 TO 15 OF ASTM B824-11. WHERE THERE
IS CONFLICTING INFORMATION THIS SPECIFICATION TAKES PRECEDENCE OVER ASTM
B824-11.
103. UNLESS OTHERWISE SPECIFIED BY THE ORDERER THE UNIQUE HEAT
IDENTIFICATION NUMBER SHALL BE MARKED ON ALL CASTINGS.
CHEMICAL COMPOSITION
201. CHEMICAL COMPOSITION SHALL CONFORM TO THE REQUIREMENTS OF UNS NO.
C95800 LISTED IN TABLE 1 BELOW.
TABLE 1 - CHEMICAL REQUIREMENTS
CU AL FE* MN NI** SI PB SUM OF RESULTS
MIN. 79.0 8.5 3.5 0.8 4.0 99.5
MAX. 9.5 4.5 1.5 5.0 0.10 0.03
*IRON CONTENT SHALL NOT EXCEED THE NICKEL CONTENT
**NICKEL INCLUDES COBALT
202. THE COMPOSITION LIMITS DO NOT PRECLUDE THE PRESENCE OF OTHER
ELEMENTS. LIMITS MAY BE ESTABLISHED BY AGREEMENT BETWEEN MANUFACTURER
AND PURCHASER FOR THE UNNAMED ELEMENTS.
203. COPPER IS THE DIFFERENCE BETWEEN THE SUM OF RESULTS OF ALL ELEMENTS
DETERMINED AND 100%. WHEN ALL THE SPECIFICATION ELEMENTS ARE DETERMINED,
THE SUM OF RESULTS SHALL BE A MINIMUM OF 99.5%.
SCALE: FULL SHEET 3 OF 8
MECHANICAL PROPERTY REQUIREMENTS
301. THE MECHANICAL PROPERTIES SHALL BE DETERMINED FROM SEPARATELY CAST
TEST BAR CASTINGS.
302. MATERIAL FURNISHED UNDER THIS DRAWING SHALL CONFORM TO THE
MECHANICAL PROPERTIES STATED IN TABLE 2 SHOWN BELOW.
TABLE 2 - MECHANICAL REQUIREMENTS
TENSILE
STRENGTH
(KSI)
YIELD STRENGTH
0.5% EUL (KSI) ELONGATION (%)
MIN. 85 35 15
303. SEPARATELY CAST TEST BARS SHALL MEET THE PATTERN REQUIREMENTS AS
SHOWN IN FIGURES A AND B BELOW. THE MOLD MATERIAL SHALL BE SILICA SAND.
MINIMUM SAND THICKNESS AROUND THE MOLD CAVITY SHALL BE 1”. FIGURES A AND
B BELOW SHOW A SINGLE TEST BAR; MULTIPLE BARS MAY BE COMBINED IN A
SINGLE MOLD PROVIDED THE 1” MINIMUM SAND THICKNESS IS MET. THE ALLOWABLE
TOLERANCE ON ALL DIMENSIONS IS +/- 1/8”. TEST BAR DIMENSIONS SHALL
CONFORM TO FIGURE 8 OF ASTM E8/E8M FOR SMALL-SIZE SPECIMEN 3 WITH GAUGE
LENGTH FOUR TIMES THE DIAMETER (0.25” NOMINAL DIAMETER).
FIGURE A – TEST BAR PATTERN SIDE VIEW (SINGLE PATTERN)
SCALE: FULL SHEET 4 OF 8
304. ACCEPTANCE OR REJECTION SHALL BE BASED ON TENSILE STRENGTH, YIELD
STRENGTH, AND PERCENT ELONGATION. TENSILE STRENGTH AND YIELD STRENGTH
SHALL BE DETERMINED BY THE EXTENSION-UNDER-LOAD METHOD OF TEST METHODS
IN ASTM E8/E8M.
305. IN LIEU OF TEST BARS PER NOTE 303, STANDARD 0.5” NOMINAL DIAMETER
TEST BARS MAY BE POURED IAW ASTM B208, FIGURE 1 (A OR B).
CASTING REPAIR
401. ALL WELDING SHALL BE IN ACCORDANCE WITH S9074-AR-GIB-010A/278
EXCEPT AS MODIFIED BY THIS NOTE. ALL WELDERS AND WELD PROCEDURES SHALL
BE QUALIFIED IN ACCORDANCE WITH S9074-AQ-GIB-010/248. THIS SPECIFICATION
IS CHEMICALLY IDENTICAL TO MIL-B-24480A (BASE METAL GROUP S-36A PER
S9074-AR-GIB-010A/278). ANY WELD PROCEDURE QUALIFIED TO MIL-B-24480A MAY
BE USED FOR MATERIAL PRODUCED TO THIS SPECIFICATION.
402. SOUND BASE METAL IS DEFINED AS MEETING THE REQUIREMENTS OF MIL-STD-
2035A(SH), SECTION 7, CLASS 3, FINISHED MACHINE SURFACE CONDITION.
PARAGRAPHS 4.5 AND 7.5.4 AND TABLE IV DO NOT APPLY. LIQUID PENETRANT
INSPECTION (PT) SHALL BE IAW S9074-AS-GIB-010A/271.
403. PRIOR TO WELDING ALL EXCAVATIONS SHALL BE PT INSPECTED AND PREPARED
TO SOUND BASE METAL AS DEFINED IN NOTE 402.
FIGURE B – TEST BAR PATTERN END VIEW (SINGLE PATTERN)
SCALE: FULL SHEET 5 OF 8
404. UNLESS OTHERWISE SPECIFIED IN THE PART SPECIFIC DRAWING, COMPLETED
WELD REPAIRS SHALL BE PT INSPECTED AND MEET THE SOUND BASE METAL
CRITERIA AS DEFINED IN NOTE 402.
405. IN ADDITION TO THE REQUIREMENTS OF NOTE 404, WHEN MORE THAN TWO
LAYERS OF WELD ARE NECESSARY TO WELD BUILD-UP OR TO REPAIR AN
EXCAVATION, EVERY THIRD LAYER SHALL BE PT INSPECTED AND MEET THE SOUND
BASE METAL CRITERIA AS DEFINED IN NOTE 402.
406. NO PEENING IS ALLOWED ON WELD METAL NOR BASE CASTING.
407. ONLY WELD FILLER WIRE IAW MIL-CUNIAL OF MIL-E-23765/3A IS
PERMITTED.
408. WELD REPAIR DEPTH SHALL BE DETERMINED FROM THE DESIGN SURFACE.
PRIOR TO COMPLETION OF MACHINING, THE DIMENSIONAL LIMITS FOR EACH
CATEGORY (MINOR, NOMINAL AND SPECIAL IAW S9074-AR-GIB-010A/278 SECTION
13) SHALL BE INCREASED BY THE AMOUNT OF LOCAL EXCESS MATERIAL REMAINING
ON THE CASTING. MACHINING GOUGES IN THE CASTING SHALL BE TREATED AS WELD
REPAIRS AND NOT WELD BUILD-UPS (S9074-AR-GIB-010A/278 SECTION 13).
409. MINOR AND NOMINAL WELD REPAIRS AS DEFINED ABOVE MAY BE MADE AT ANY
TIME DURING THE MANUFACTURING PROCESS WITHOUT APPROVAL. SPECIAL WELD
REPAIRS AT PUBLIC SHIPYARDS SHALL BE APPROVED BY THE NAVSEA AUTHORIZED
REPRESENTATIVE FOR INDIVIDUAL REPAIRS OF PROPULSORS PER S9074-AR-GIB-
010A/278 PRIOR TO WELDING. SPECIAL WELD REPAIRS AT NON-PUBLIC SHIPYARDS
REQUIRE NAVSEA 05P3 APPROVAL PRIOR TO WELDING.
410. ALL WELD REPAIRS, INCLUDING MINOR WELD REPAIRS, SHALL BE RECORDED
AND INCLUDE THE FOLLOWING:
A. A SKETCH, DRAWING OR PICTURE SHOWING THE DIMENSIONS DEPTH AND
LOCATIONS
B. WELD REPAIR INSPECTION RESULTS
C. CASTING IDENTIFICATION NUMBER
D. WELD REPAIR PROCEDURE IDENTIFICATION NUMBER
E. WELDER IDENTIFICATION
F. INSPECTOR IDENTIFICATION
411. CASTINGS SHALL NOT BE IMPREGNATED.
SCALE: FULL SHEET 6 OF 8
QUALITY ASSURANCE
501. UNLESS OTHERWISE SPECIFIED, THE MANUFACTURER IS RESPONSIBLE FOR
PERFORMANCE OF ALL INSPECTIONS AND TEST REQUIREMENTS SPECIFIED. THE
MANUFACTURER MAY USE ITS OWN OR ANY OTHER SUITABLE FACILITIES FOR THE
PERFORMANCE OF THE INSPECTION AND TEST REQUIREMENTS UNLESS DISAPPROVED
BY THE PURCHASER AT THE TIME THE ORDER IS PLACED. THE PURCHASER SHALL
HAVE THE RIGHT TO PERFORM ANY OF THE INSPECTIONS OR TESTS SET FORTH WHEN
SUCH INSPECTION AND TESTS ARE DEEMED NECESSARY TO ENSURE THAT THE
MATERIAL CONFORMS TO PRESCRIBED REQUIREMENTS.
CERTIFICATION
601. THE PURCHASER SHALL BE FURNISHED CERTIFICATION THAT SAMPLES
REPRESENTING EACH APPLICABLE HEAT HAVE BEEN TESTED AND INSPECTED AS
DIRECTED IN THIS SPECIFICATION AND REQUIREMENTS HAVE BEEN MET. THIS
CERTIFICATION SHALL INCLUDE ACTUAL CHEMICAL AND MECHANICAL TEST RESULTS.
SCALE: FULL SHEET 7 OF 8
SUPPLEMENTARY REQUIREMENTS
THE FOLLOWING SUPPLEMENTARY REQUIREMENTS SHALL APPLY ONLY WHEN SPECIFIED BY THE
PURCHASER IN THE DRAWING OR CONTRACT.
S1. MOLD DESIGN DOCUMENTATION APPROVAL.
VENDOR SHALL SUBMIT TO NAVSEA 05P3 FOR NAVSEA 05P3 APPROVAL THE
FOLLOWING INFORMATION AT LEAST 30 DAYS PRIOR TO POURING THE CASTING:
1. DOCUMENTATION OF THE PLANNED MOLDING AND POURING OF THE CASTING IN
ACCORDANCE WITH LATEST REVISION OF NAVSEA DRAWING 810-7642133.
2. RESULTS OF CASTING SIMULATIONS OF THE PROPOSED MOLD DESIGN ALONG
WITH RATIONALE AS TO WHY THE CASTING SIMULATIONS REPRESENT THE
ACTUAL POUR IN ACCORDANCE WITH LATEST REVISION OF NAVSEA DRAWING
810-7642133.
VENDOR SHALL SUBMIT TO NAVSEA 05P3 THE FOLLOWING INFORMATION WITHIN 60
DAYS AFTER THE POUR IS COMPLETE:
1. DOCUMENTATION OF THE ACTUAL AS-BUILT MOLD AND ACTUAL POURING
CONDITIONS.
S2. MOLD DESIGN AND CASTING PROCESS APPROVAL
THE VENDOR SHALL PRESENT TO NAVSEA 05P3 FOR NAVSEA 05P3 APPROVAL PRIOR
TO MOLDING. THE PRESENTATION SHALL INCLUDE AT A MINIMUM:
1. THE MOLD DESIGN DOCUMENTATION LISTED IN S1 ABOVE AND THE
ENGINEERING RATIONALE WHICH SUPPORTS IT.
2. EVALUATION RESULTS OF SIMILAR SIZED CASTINGS RECENTLY COMPLETED
INCLUDING A COMPARISON OF THE ACTUAL CASTING QUALITY VS THE
PREDICTED CASTING QUALITY AND THE RATIONALE FOR CHANGES FROM PAST
PRACTICES.
SCALE: FULL SHEET 8 OF 8
S3. EXTRACTED MECHANICAL SAMPLES
MECHANICAL TEST SAMPLES SHALL BE TAKEN FROM THE LOCATION DESIGNATED ON
THE PART DRAWING (OR LOCATION SPECIFIED BY THE PURCHASER) AND MEET THE
FOLLOWING MINIMUM REQUIREMENTS:
TABLE 3 – EXTRACTED SAMPLE MECHANICAL REQUIREMENTS
TENSILE
STRENGTH
(KSI)
YIELD STRENGTH
0.5% EUL (KSI) ELONGATION (%)
MIN. 60 24 10
S4. SURFACE INSPECTION PRIOR TO FINAL MACHINING
PRIOR TO FINAL MACHINING, ALL SURFACES SHALL MEET PT REQUIREMENTS OF
SOUND BASE METAL PER NOTE 402. FIXTURING DATUMS MAY BE FINISH MACHINED
WITHOUT THIS PT INSPECTION PROVIDED THOSE SURFACES ARE PT INSPECTED TO
THE PART SPECIFIC DRAWING REQUIREMENTS PRIOR TO ANY OTHER MACHINING.
S5. FIRST ARTICLE INSPECTION
THE FIRST CASTING AFTER MOLD DESIGN APPROVAL SHALL UNDERGO DESTRUCTIVE
TESTING. A CUTTING PLAN SHALL BE REVIEWED AND APPROVED BY NAVSEA 05P3.
AT A MINIMUM THE CUTTING PLAN SHALL SPECIFY CUTS AT LOCATIONS WITH THE
HIGHEST PROCLIVITY OF SHRINKAGE BASED ON CASTING SIMULATION SOFTWARE
RESULTS AND AT MAJOR ATTACHMENT HOLE LOCATIONS. ALL CUT SURFACES SHALL
BE LIQUID PENETRANT INSPECTED AND EVALUATED IAW SOUND BASE METAL
REQUIREMENTS PER NOTE 402.
ONCE THE DESIGN IS APPROVED, ANY SIGNIFICANT MOLD DESIGN CHANGE (AS
DETERMINED BY NAVSEA 05P3) WILL REQUIRE A NEW DESTRUCTIVE FIRST ARTICLE
TEST. THE VENDOR MAY SUBMIT FOR NAVSEA 05P3 APPROVAL A JUSTIFICATION WHY
DESTRUCTIVE TESTING IS NOT REQUIRED. AN ALTERNATE PLAN SUCH AS SPLITTING
RISERS AND COMPARING TO SIMULATION RESULTS MAY ALSO BE SUBMITTED FOR
NAVSEA 05P3 APPROVAL.
2018-01-23T11:31:14-0500
WELLS.MEREDITH.I.1094673689
DISTRIBUTION STATEMENT A
APPROVED FOR PUBLIC RELEASE.
DISTRIBUTION IS UNLIMITED
Mike_K
MK sign
Text Box
12/20/11 cdh dpd gen
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
image1.png image2.png
COVER
CONTENTS
FIGURES
TABLES
File details come from the government source that posted it.