MQ-011.pdf

PDF 257 KB Posted

Attached to
Expand and Upgrade Building 42 for Laboratory
Solicitation number
36C25520R0073-0007
Issued by

About this file

This document contains mechanical drawings and details for the expansion and upgrade of Building 42 at the Marion, Illinois VA Medical Center to accommodate new laboratory facilities. Key specifications include the installation of new chilled water circulation pumps and hot water convertors to service variable air volume AHUs supplying both heating and cooling for the building. The mechanical systems shown are designed to control temperature, humidity and air flow throughout the building while meeting medical gas detection, smoke detection and fire alarm requirements. The related federal contract opportunity is a solicitation from the Department of Veterans Affairs for design and construction services for the Expand and Upgrade Building 42 for Laboratory project at the Marion VA Medical Center, with responses due under Solicitation Number 36C25520R0073-0007.

View the file

Other files

File Type Posted
MC-101.pdf PDF
36C25520R0073 0007.docx DOCX document
FINAL QUESTIONS AND ANSWERS 657-502.docx DOCX document
MQ-008.pdf PDF
MQ-009.pdf PDF
233600 - Air Terminal Units R1.doc DOC document
074213.23 SF - METAL COMPOSITE MATERIAL WALL PANELS.doc DOC document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BUILDING CHILLED WATER:

HOT WATER CIRCULATING PUMP (HWP-1)

HOT WATER CONVERTOR (HE-1)

BUILDING HEATING SYSTEM:

VOLUME REHEAT SYSTEMS:

VARIABLE AIR

AHU-1

SUPPLY FAN

RETURN FAN

SUPPLY AIR

RETURN AIR

MIXED AIR

PREHEAT COIL

COOLING COIL

PRE-FILTER

AFTER FILTER

DAMPERS (RET/MIXED AIR)

OUTSIDE AIR

HUMIDITY SENSORS

CHILLED WATER LOOP

SPACE TEMPERATURE:

TERMINAL BOXES SYSTEM AHU-1 (SEE NOTE 2)

HOT WATER CIRCULATING PUMP (HWP-2)

M

ED

IC

AL

G

AS

ES

LE

AK

D

ET

EC

TI

O N

SM

O

KE

D

ET

EC

TI

O

N/

FI

RE

A

LA

RM

PU

M

P

FA

IL

UR

E

VA

CU

UM

IN

-H g

LOCATION:SERVICE:

DESCRIPTION

VETERANS AFFAIRS

DA

M

PE

R

PO

SI

TI

O

N

SU

PP

LY

A

IR

T

EM

PE

RA

TU

RE

CONTROL POINTS

RU

N

TI

M

E M

AI

NT

EN

AN

CE

CH

IL

L.

W

TR

. P

L' T

O

PT

IM

IZ

O .A

. D

AM

PE

R

PO

SI

TI

O

N

VA

R.

S

PE

ED

D

RI

VE

M O

D.

RE

T.

A

IR

H

UM

ID

IT

Y

RH

DI

FF

. P

RE

SS

. F

T-

HD

DI

FF

. P

RE

SS

. I

N.

W

T' R.

DI

SC

HA

RG

E

AI

R

TE

M P.

ST

AT

IC

P

RE

SS

. I N.

W T'

R

IN

LE

T

PR

ES

S.

P

SI

G

IN

LE

T

TE

M P.

D

EG

. F

LO

W

L

EV

EL

O N-

O

FF

DA

M

PE

R-

O

PE

N/

CL

O

SE

D

CO

NT

RO

L

VA

LV

E

CO

NT

RO

L

DA

M

PE

R

W

AT

ER

T

EM

P.

D

EG

. F

AI

R

TE

M

P.

D

EG

. F

O N-

O

FF

CONTROL

DIGITAL ANALOG

CONTROL

MONITORING POINTS

DIGITAL STATUS

FR

EE

ZE

ST

AT

HI

G

H

LE

VE

L

ANALOG STATUS

O

UT

LE

T

TE

M

P.

D

EG

. F

O

UT

LE

T

PR

ES

S.

P

SI

G

FL

O

W , G

PM

CF

M

A

IR

F

LO

W

RE

TU

RN

A

IR

T

EM

P.

O

UT

SI

DE

A

IR

T

EM

P.

CO

O

L.

C

O

IL

V

AL

VE

P

O

SI

TI

O

N

PR

E-

HE

AT

C O

IL

V

AL

VE

P O

S.

O .A

. A

IR

H

UM

ID

IT

Y

RH

DI

SC

H.

A

IR

H

UM

ID

IT

Y

RH

SP

AC

E

TE

M P.

D

EG

. F

SP

AC

E

HU

M

ID

IT

Y

RH

PO

W

ER

K

W

ECC ALARM INDICATION OUTPUTS

FR

EE

ZE

ST

AT

FA

N

FA

IL

UR

E

FI

LT

ER

H

IG

H

LI

M

IT

HI

G

H

TE

M

PE

RA

TU

RE

LO

W

T

EM

PE

RA

TU

RE

HI

G

H

HU

M

ID

IT

Y

LO

W

H

UM

ID

IT

Y

HI

G

H

PR

ES

SU

RE

LO

W

P

RE

SS

UR

E

HI

G

H

LE

VE

L

LO

W

L

EV

EL

RU

N

TI

M

E

SOFTWARE PROGRAMS

EC

O

NO

M

IZ

ER

C O

NT

RO

L

TI

M

E

SC

HE

DU

LI

NG

O

PT

IM

UM

S

TA

RT

/S

TO

P

EV

EN

T

PR

O G

RA

M

RE

SE

T

AU

TO

M

AT

IC

R

ES

TA

RT

G

RA

PH

IC

S

POINTS LIST SCHEDULE FOR ENGINEERING CONTROL CENTER (ECC)

SM

O

KE

D

ET

EC

TI

O

N

AI

R

VO

LU

M E

CO

NT

RO

L

PR

ES

SU

RE

MEDICAL CENTER

MARION,

ILLINOIS

MEZZANINE

NOTES: 1. SIGNAL VIA UNIT-MOUNTED PITOT TUBE. SEE DETAIL.

2. SEE PLANS FOR T'STAT AND TERMINAL UNIT LOCATIONS.

SYSTEM POINT

HUMIDIFIER, STEAM

AHU-2

SUPPLY FAN

RETURN FAN

SUPPLY AIR

RETURN AIR

MIXED AIR

PREHEAT COIL

COOLING COIL

PRE-FILTER

AFTER FILTER

HEAT WHEEL

OUTSIDE AIR

HUMIDITY SENSORS

HUMIDIFIER, STEAM

HEPA FILTER

BT

U/

TE

M P/

PR

ES

S/ M

ET

ER

EF-1

EF-2

EF-3

AC-1 AND AC-2

Drawing Title Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date CONSULTANTS: ARCHITECT/ENGINEERS:

42-AdditionApproved: Associate Director

Approved: Chief of Staff

Approved: Chief Engineer

Approved: Infection Control

Approved: Safety Officer

Approved: Chief, Police & Security o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

1 Memorial Dr. STE 1800 Saint Louis, MO 63102 Tel

Fax

314.621.4343 314.621.0261

220 N College Ave Indianapolis, IN 46202 Tel

Fax

317.464.9090 317.464.9393

Office of Facilities

ManagementMcComas Engineers 1717 E 116th Street Carmel, IN 46032 Tel

Fax

317.580.0402 317.582.0766

Structural Asaturian Eaton & Assoc.

1440 Old West Main Carbondale, IL 62901 Tel

Fax

618.529.3414 618.529.3423

Civil John A Jurgiel & Assoc.

123 N. Main Street St. Charles, MO 63301 Tel

Fax

636.757.3060 636.757.3064

Industrial Hygenist Holcomb Foundation 393 Wood Road Carbondale, IL 62901 Tel

Fax

618.529.5262 618.457.8991

Geotechnical

SHEET UPDATED PER ADDENDUM 08-06-20

ENGINEER

S

T

A

T

E

O

F

I

L

L

N

O

I

S

E

R

A

W

L

U

O

B E

D

A

W

L

R

A

E

I

062-044274

REGISTERED

PROFESSIONAL

Expand & Upgrade Building 42 for Laboratory

657-502

Marion, IL

11-07-2019

Bid Document

DH BZ

MECHANICAL DETAILS

MQ-011

Sheets and Views
Layout1

File details come from the government source that posted it. Updated .