Mabley Sidewalk Requirements - Per DOT Standards.docx
DOCX document 118 KB Posted
- Contract number
- 26-444DHS-DEVDI-P-98336
- Issued by
- Illinois
About this file
This document is a technical specification and requirements guide for sidewalk construction work in Portland, Oregon, outlining standards that must be met by contractors performing work for the City of Mabley under Department of Transportation (DOT) specifications.
The specification details the construction of 5-inch thick portland cement concrete sidewalks and accessibility ramps on prepared subgrades, with materials and methods requirements including a 4-inch compacted aggregate base, minimum 2-inch thick side forms, and broom-finished concrete surfaces. Concrete panels must be between 4 and 6 feet in length (typical 5-foot by 5-foot configuration) with proper jointing, expansion joints of specified thickness between sidewalks and structures, and ADA-compliant curb ramps with detectable warning surfaces of truncated domes. Materials specifications require IDOT State-approved PV/SI concrete mix and CA 6 or CA 10 gradation aggregate subbase material. The work requires completion of each phase before proceeding to the next phase unless otherwise approved by Mabley staff, with finishing work including membrane curing compound application, topsoil restoration, and lawn seed and fertilizer placement in disturbed areas. The specification permits flexibility in concrete spray cure types and lawn seed and fertilizer selections.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| BEP Utilization Plan v.26.1~2.pdf | ||
| DHS IFB Mabley Sidewalks-B-52497.docx | DOCX document | |
| invitation-for-bid-offer-to-the-state-of-illinois-B-52497.pdf | ||
| Sample.pdf | ||
| vendor-disclosure-formerly-forms-a-v26-2-7-22-2025~26.docx | DOCX document | |
| invitation-for-bid-vendor-instructions-and-requirements-B-52497.docx | DOCX document | |
| CO150~2.docx | DOCX document | |
| Notice of Award - Bid-52497_Signed.pdf | ||
| ipg-active-registered-vendor-disclosure-formerly-forms-b-v-26-1-8-26-2025-1~31.docx | DOCX document | |
| Phase Diagram.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Portland Cement Concrete Sidewalk 5” Description:
· This work shall consist of constructing 5 inch thick portland cement concrete sidewalk and sidewalk accessibility ramps on a prepared subgrade.
· The subgrade shall consist of 4 inches of aggregate and be compacted with a plate compactor before concrete placement.
· Side forms shall be a minimum of 2 inches thick (nominal dimension) lumber or steel of equal rigidity. They shall be held securely in place by stakes or braces, with the top edges true to line and grade.
· The subgrade shall be moistened just before the concrete is placed. The concrete shall be placed in successive batches for the entire width of the slab, struck off, consolidated with a hand vibrator, and finished to a true and even surface with floats and trowels.
· Steel trowels shall not be permitted.
· Concrete shall have a broom finish.
· Concrete shall not be placed on frozen ground.
· Sidewalk must be edged with a ¼ inch radius and must be jointed or saw cut to a depth of ¼ the depth of the sidewalk.
· No sidewalk panel shall be longer than 6ft nor less than 4ft. (Typical 5ft by 5ft panel)
· Expansion joints shall be ½ inch thick and shall be placed between the sidewalk and all structures.
· Curb ramps shall be constructed according to ADA standards.
· Detectable warnings shall consist of a surface of truncated domes meeting accessibility standards.
· Concrete shall be cured with a membrane curing compound after all finish work is complete.
· Topsoil shall be used to fill any disturbed areas needing touched up after formwork is removed.
· Lawn seed and fertilizer shall be placed in any disturbed areas.
Materials:
· Concrete used shall be an IDOT State approved PV/SI mix.
· Aggregate subbase material shall be CA 6 or CA 10 gradation.
· Any type of concrete spray cure shall be permitted.
· Any type of lawn seed and fertilizer shall be used.
Notes:
· Each Phase must be completed before the next Phase is started unless approved by Mabley staff.
Typical Sidewalk Section image1.png