JLM Ground to 9th floor life safety drawings.pdf
PDF 7 MB Posted
- Attached to
- H141--HVAC Fire Damper Testing Services Federal contract opportunity
- Solicitation number
- 36C25625Q1473
About this file
These documents are Life Safety floor plans for the J.L. McClellan VA Medical Center located in Little Rock, Arkansas, detailing a comprehensive fire and safety documentation for a multi-story medical facility (Building 1). The floor plans comprehensively illustrate the building's nine floors, each with distinct occupancy types ranging from Business (Ground Floor), Mixed Occupancy (First and Second Floors), Healthcare Occupancy (Third through Sixth Floors), and Industrial Occupancy (Eighth and Ninth Floors).
The plans include detailed color-coded partition legends indicating fire barriers, smoke zone barriers, and hazardous room enclosures, with specific annotations referencing NFPA (National Fire Protection Association) codes and standards. Each floor plan features a suite description table documenting room numbers, names, sizes, occupancy types, and exit numbers, along with smoke zone charts breaking down square footage and occupancy classifications. The documentation is meticulously prepared by Systech Fire Protection LLC and includes comprehensive life safety considerations such as fire sprinkler systems, alarm systems, corridor classifications, and strategic compartmentalization to support emergency evacuation and containment protocols.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25625Q1473 0001.docx | DOCX document | |
| LRVA Medical-Center---Dampers 6 year.xlsx | XLSX spreadsheet | |
| North Little Rock ground to 4th floor life safety drawings.pdf | ||
| Wage Determination 15-5117.txt | TXT text file | |
| NLR-Bldg--170---Dampers 6 year.xlsx | XLSX spreadsheet | |
| 36C25625Q1473.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WALL:
DUCTS:
PENETRATIONS:
DOORS*:
WALL:
DUCTS:
DOORS:
WALL:
DUCTS:
PENETRATIONS:
DOORS:
WALL:
DUCTS:
DOORS:
2-HOUR FIRE BARRIER
THIS APPLIES TO OCCUPANCY SEPARATION WALLS, HORIZONTAL EXITS, AND STAIRWELLS OF
4 OR MORE STORIES.
2-HOUR FIRE AND SMOKE ZONE BARRIER
THIS APPLIES TO OCCUPANCY SEPARATION WALLS, HORIZONTAL EXITS, AND
STAIRWELLS OF 4 OR MORE STORIES. THIS COMBINATION WALL IS WHERE A PORTION
OF THE 2-HOUR RATED WALL IS ALSO PART OF THE SMOKE WALL.
1-HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)
THIS APPLIES TO 1-HOUR FIRE RATED OCCUPANCY SEPERATIONS, HAZARDOUS ROOM
ENCLOSURES AND STAIRWELLS 3 STORIES OR LESS.
SMOKE ZONE BARRIER
SUBSTANTIAL WALLS AND DOORS TO DIVIDE EACH FLOOR INTO COMPARTMENTS FOR
DEFEND IN PLACE EMERGENCY OPERATIONS. IF THE SMOKE ZONE BARRIER WALL IS
OF MASONRY, GYPSUM BOARD, OR METAL LATH AND PLASTER CONSTRUCTION, AND
THE BARRIER WAS CONSTRUCTED POST 1948, THE SMOKE ZONE BARRIER WALLS ARE
REQUIRED TO BE OF 1 HOUR FIRE RESISTANCE RATING. (NFPA 101, 18.3.2.7.5) SMOKE
ZONE BARRIER WALLS OF WOOD LATH AND PLASTER CONSTRUCTION ARE PERMITTED
TO BE OF A 12 HOUR FIRE RESISTANCE RATING (NFPA 101, 19.3.7.3)
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
(COLOR #5)
(COLOR #4)
(COLOR #1)
(COLOR #230)
(COLOR #3)
NOTE: ALL CODE REFERENCES ARE PER THE 2021 EDITION OF NFPA 101 LIFE SAFETY CODE AND THE OTHER APPLICABLE CODES.
DOORS: DOORS THAT ARE NOT PART OF A RATED WALL:
1. NON-LABELED FRAME (NFPA 101 18.3.6.3.1, 19.3.6.3 & 19.3.6.3.3)
2. NON-RATED DOORS PERMITTED IF SPRINKLERED (NFPA 101
18.3.6.3.1, 19.3.6.3.2(2))
3. 20-MINUTE OR SOLID WOOD CORE DOOR IF NOT SPRINKLERED (NFPA 101 19.3.6.3.1) 1 3 4" THICK.
4. POSITIVE LATCHING EXCEPT TOILETS, SHOWER AND SINK
CLOSETS (NFPA 101 18.3.6.3.6 & 19.3.6.3.6)
5. SELF-CLOSING NOT REQUIRED (NFPA 101 19.3.6.3.11)
6. NO MAXIMUM GAP (NFPA 101 18.3.6.3.1 & 19.3.6.3.3)
7. MAXIMUM 1" UNDERCUT (NFPA 101 18.3.6.3.1 & 19.3.6.3.4)
8. UNLIMITED HEIGHT PROTECTIVE PLATE (NFPA 101 18/19.3.6.3.12)
9. TRANSFER GRILLS NOT PERMITTED EXCEPT TOILETS,
SHOWER AND SINK CLOSETS (NFPA 101 18/19.3.6.4)
10. SWING IN ANY DIRECTION
11. SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY (NFPA 105 5.2.1.1)
(COLOR #30)
NON-RATED SMOKE ZONE PARTITION
FORMER DECOMMISSIONED SMOKE BARRIER RETAINED AS FIRE ALARM/SPRINKLER
ZONE. BUILDING OCCUPANTS PERMITTED TO DEFEND IN PLACE UNTIL DIRECTED BY
THE FIRE DEPARTMENT PER SECTION 16.7.4.3 OF NFPA 99-2021 EDITION AND PRIVATE
MODE AUDIBLE REQUIREMENTS OF SECTION 16.7.4.3 OF NFPA 72-2019 EDITION.
WALL:
DUCTS:
PENETRATIONS:
DOORS:
HEALTH CARE OCCUPANCY CORRIDORS
IF THE SMOKE COMPARTMENT IS SPRINKLERED, THE WALL SHALL FORM A BARRIER TO LIMIT THE TRANSFER OF SMOKE. THE WALL HAS NO REQUIRED FIRE RESISTANCE RATING AND MAY TERMINATE AT A CEILING CONSTRUCTED
TO LIMIT TRANSFER OF SMOKE.
IF THE SMOKE COMPARTMENT IS NOT SPRINKLERED, THE WALL SHALL BE CONTINUOUS FROM THE FLOOR TO THE UNDERSIDE OF THE FLOOR OR ROOF DECK ABOVE. CORRIDOR WALL SHALL HAVE A MINIMUM 1/2 HOUR FIRE RESISTANCE RATING. DOORS ARE MANUALLY CLOSED IN AN EMERGENCY NFPA 101 19.3.6.2 AND 18.3.6.2
PENETRATIONS:
WALL EXTENDS FROM FLOOR TO DECK ABOVE.
ALL DUCT PENETRATIONS ARE PROTECTED BY FIRE DAMPERS.
ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP
MATERIALS FOR PROTECTING 2-HOUR WALL ASSEMBLIES. WALL
PENETRATIONS ARE REQUIRED TO BE FILLED ON BOTH SIDES OF THE
WALL. FLOOR PENETRATIONS ARE ONLY REQUIRED TO BE FILLED ON
THE TOP OF THE FLOOR.
ALL DOORS REQUIRE THE FOLLOWING:
1. LABELED FRAMES (NFPA 80 4.2.1)
2. LABELED 1 1/2 HOUR DOOR (NFPA 80 4.3.1)
3. MAXIMUM 100 SQ. IN. WINDOW (NFPA 80 TABLE 4.4.5)-LIMITED TO
MAX AREA LISTED.
4. POSITIVE LATCHING (NFPA 80 6.4.1.4)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)
6. COORDINATING DEVICES REQUIRED (NFPA 80 6.4.1.2.1)
7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7.3)
8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)
9. MAXIMUM 16" PROTECTIVE PLATE (NFPA 80 6.4.5.1)
10. SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101 18/19.2.2.2).
11. PERIODIC INSPECTION AND TESTING SHALL BE PERFORMED AT
LEAST ANNUALLY (NFPA 80 5.2.4.1)
* 2 HOUR DOOR REQUIRED FOR STAIRWELLS 4 OR MORE STORIES
(NFPA 101 7.1.3.2.1)(3).
WALL:
DUCTS:
PENETRATIONS:
DOORS:
WALL EXTENDS FROM FLOOR TO DECK ABOVE.
ALL DUCT PENETRATIONS ARE PROTECTED BY COMBINATION FIRE AND
SMOKE DAMPERS. SMOKE DAMPERS ARE NOT REQUIRED WHERE
ADJACENT SMOKE COMPARTMENTS ARE PROTECTED BY QUICK
RESPONSE SPRINKLERS THROUGHOUT EACH COMPARTMENT.
ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP
MATERIALS FOR PROTECTING 2-HOUR WALL ASSEMBLIES. WALL
PENETRATIONS ARE REQUIRED TO BE FILLED ON BOTH SIDES OF THE
WALL. FLOOR PENETRATIONS ARE ONLY REQUIRED TO BE FILLED ON
THE TOP OF THE FLOOR.
ALL DOORS REQUIRE THE FOLLOWING:
1. LABELED FRAMES (NFPA 80 4.2.1)
2. LABELED 1 1/2 HOUR DOOR (NFPA 80 4.3.1)
3. MAXIMUM 100 SQ. IN. WINDOW (NFPA 80 4.4.5)
4. POSITIVE LATCHING (NFPA 80 6.4.1.4)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)
6. COORDINATING DEVICES REQUIRED (NFPA 80 6.4.1.2.1)
7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7.3)
8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)
9. MAXIMUM 16" PROTECTIVE PLATE (NFPA 80 6.4.5.1)
10. SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101 18/19.2.2.2).
11. PERIODIC INSPECTION AND TESTING SHALL BE PERFORMED AT
LEAST ANNUALLY (NFPA 80 5.2.4.1)
WALL EXTENDS FROM FLOOR TO DECK ABOVE.
STEEL DUCT PENETRATIONS NOT REQUIRED TO BE PROTECTED BY FIRE
DAMPERS.
ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR
PROTECTING 1-HOUR WALL ASSEMBLIES. WALL PENETRATIONS ARE REQUIRED
TO BE FILLED ON BOTH SIDES OF THE WALL. FLOOR PENETRATIONS ARE ONLY
REQUIRED TO BE FILLED ON THE TOP OF THE FLOOR.
ALL DOORS REQUIRE THE FOLLOWING:
1. LABELED FRAMES (NFPA 80 4.2.1)
2. LABELED 3/4 OR 1-HOUR DOOR (NFPA 80 4.3.1)*
3. MAXIMUM 100 SQ. IN. WINDOW (NFPA 80 TABLE 4.4.5)
4. POSITIVE LATCHING (NFPA 80 6.4.1.4)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)
6. COORDINATING DEVICES REQUIRED (NFPA 80 6.4.1.2.1)
7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7.3)
8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)
9. MAXIMUM 16" PROTECTIVE PLATE (NFPA 80 6.4.5.1)
10.SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101 18/19.2.2.2).
11.PERIODIC INSPECTION AND TESTING SHALL BE PERFORMED AT LEAST
ANNUALLY (NFPA 80 5.2.4.1)
* 1-HOUR DOORS ARE REQUIRED IN STAIRWELLS THAT ARE 3 STORIES OR
LESS. (NFPA101 7.1.3.2.1)(1)
WALL EXTENDS FROM FLOOR TO DECK ABOVE.
ALL DUCT PENETRATIONS ARE PROTECTED BY SMOKE DAMPERS. SMOKE
DAMPERS ARE NOT REQUIRED WHERE ADJACENT SMOKE COMPARTMENTS ARE
PROTECTED BY QUICK RESPONSE SPRINKLERS THROUGHOUT EACH
COMPARTMENT.
ALL PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR
PROTECTING 1-HOUR FIRE AND SMOKE WALL ASSEMBLIES. PENETRATIONS ARE
TO BE FILLED ON BOTH SIDES OF THE WALL.
ALL DOORS FOR SMOKE BARRIERS REQUIRE THE FOLLOWING:
1. NON-LABELED FRAME (NFPA 101 18.3.7.6)
2. 20 MINUTE OR SOLID WOOD CORE (NFPA 101 18.3.7.6) 1 3 4" THICK.
3. MAXIMUM SIZE LISTED WINDOW (NFPA 80 TABLES 4.4.5)
4. POSITIVE LATCHING NOT REQUIRED (NFPA 101 18.3.7.8)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 18.3.7.8)
6. MAXIMUM 1/8" GAP (NFPA 101 18.3.7.6.)
7. MAXIMUM 3/4" UNDERCUT (NFPA 101 8.5.4)
8. UNLIMITED IN HEIGHT PROTECTIVE PLATE (NFPA 101 18.3.7.6/19.3.7.6.1
9. SWING IN DIRECTION OPPOSITE OF EACH OTHER (NFPA 101 18.3.7.6)
10.SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY (NFPA 105
5.2.1.1)
IF THE HAZARDOUS ROOM HAS A SUSPENDED CEILING CONSTRUCTED TO LIMIT
TRANSFER OF SMOKE, THE WALL HAS NO FIRE RESISTANCE RATING AND MAY
TERMINATE AT THE CEILING. IF THE ROOM DOES NOT HAVE A SUSPENDED
CEILING, THE WALL HAS NO FIRE RESISTANCE RATING AND SHALL EXTEND TO
THE DECK ABOVE.
STEEL DUCT PENETRATIONS ARE NOT REQUIRED TO BE PROTECTED BY FIRE
DAMPERS OR SMOKE DAMPERS.
SEALED WITH NON-FIRE-RATED MATERIALS TO BE RESISTIVE. USE OF LISTED
FIRESTOP MATERIALS IS NOT REQUIRED.
EXISTING HAZARDOUS ROOMS:
1. NON-LABELED FRAME (NFPA 101 19.3.7.9)
2. 20 MINUTE OR SOLID WOOD CORE (NFPA 101 19.3.7.6) 1 3 4" THICK.
3. MAXIMUM 1296 SQ. IN. WINDOW (NFPA 101 19.3.6.3.17)
4. POSITIVE LATCHING NOT REQUIRED (NFPA 101 19.3.6.3.5)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 19.3.2.1.3)
6. MAXIMUM 1/8" GAP (NFPA 101 19.3.6.3.1)
7. MAXIMUM 1" UNDERCUT (NFPA 101 19.3.6.3.4)
8. MAXIMUM 48" PROTECTIVE PLATE (NFPA 101 19.3.2.1.2)
9. SWING IN ANY DIRECTION
10.SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY (NFPA
105 5.2.1.1)
PENETRATIONS:
WALL EXTENDS FROM FLOOR TO SUSPENDED CEILING OR DECK ABOVE.
NO MINIMUM REQUIREMENTS.
NO MINIMUM REQUIREMENTS FOR WALL PENETRATIONS ABOVE A SUSPENDED
CEILING. PENETRATIONS BELOW A SUSPENDED CEILING OR DECK SEALED
WITH NON-FIRE-RATED MATERIALS TO BE SMOKE RESISTIVE.
NON-FIRE-RATED DOORS AND FRAMES SELF CLOSING OR AUTOMATIC CLOSING
IN AN EMERGENCY.
(COLOR #30)
EW
FAAP
FACP
FIRE EXTINGUISHER
EXIT SIGN
EMERGENCY LIGHT
FIRE ALARM STATION
FIRE ALARM CONTROL PANEL
FIRE ALARM ANNUNCIATOR PANEL
AUTOMATED EXTERNAL DEFIBRILLATOR
F
AED
EYEWASH STATION
SPRINKLER SYSTEM RISER
SH SHOWER STATION
EVACUATION CHAIREVC
FIRE HOSE VALVEFHV
SYMBOLS LIST
SUITE DESIGNATION
(COLOR #2)
HEALTHCARE AREA OPEN TO CORRIDOR WITH 24
7 SUPERVISION - NO SMOKE
DETECTION REQUIRED.
(COLOR #3)
HEALTHCARE AREA OPEN TO CORRIDOR - SMOKE DETECTION PROVIDED.
(COLOR #2)
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE
(COLOR #230)
(COLOR #4)
FIRE/SMOKE BARRIER
DESCRIPTION AND SYMBOLS LIST
X-01
LIFE SAFETY
SITE NAME/ADDRESS
REVISIONS: NUMBER DATE
ENGINEERS
Approved: Project Director Location
Issue Date
Drawing Title Project Title
Building Number
Drawing Number
Dwg.
Project Number
139 Old Creek Road Palos Park, IL 60464 and 12200 Bunya Lane Ruther Glen, VA 22546 Tel: 703-477-5928 Email: dale.wheeler@systechfire.com Checked By
DRW / JSW
Drawn By
TCG07/12/2023 of 13
J.L. McCLELLAN VAMC
STATEMENT OF CONDITIONS
DOCUMENTATION
LITTLE ROCK, ARKANSAS
Dept. of Veterans Affairs Medical Center 4300 W. 7th Street Little Rock, Arkansas 72205
APPLICABLE CODES AND STANDARDS:
1. THE ORIGINAL BUILDING WAS BUILT IN 1982 AND DESIGNED TO THE UNIFORM BUILDING CODE 1979
EDITION.
2. THE JOINT COMMISION HAS ADOPTED THE NATIONAL FIRE CODES PUBLISHED BY THE NATIONAL FIRE
PROTECTION ASSOCIATION. LIFE SAFETY REQUIREMENTS ARE SPECIFICALLY ADDRESSED IN THE 2012
EDITION OF NFPA 101, LIFE SAFETY CODE.
3. ALL NEW CONSTRUCTION OR BUILDING RENOVATIONS ARE REQUIRED TO COMPLY WITH THE 2012 EDITION OF NFPA 101 OR IT'S REFERENCED STANDARDS. EXISTING BUILDING CONDITIONS ARE REQUIRED TO COMPLY WITH THE APPLICABLE CODES OR STANDARDS AT THE TIME OF BUILDING DESIGN AND THE APPLICABLE PROVISIONS FOR EXISTING BUILDINGS IN CURRENT EDITIONS OF APPLICABLE
CODES AND STANDARDS.
4. OTHER NFPA CODES AND STANDARDS:
A. NFPA 10 - PORTABLE FIRE EXTINGUISHERS, 2010 EDITION.
B. NFPA 13 - SPRINKLER SYSTEMS, 2010 EDITION.
C. NFPA 14 - STANDPIPE SYSTEMS, 2010 EDITION.
D. NFPA 20 - FIRE PUMPS, 2019 EDITION
E. NFPA 70 - NATIONAL ELECTRIC CODE, 2011 EDITION.
F. NFPA 72 - NATIONAL FIRE ALARM CODE, 2010 EDITION.
G. NFPA 75 - ELECTRONIC COMPUTER EQUIPMENT, 2017 EDITION.
H. NFPA 80 - FIRE DOORS, 2010 EDITION.
I. NFPA 90A&B - HEATING AND AIR CONDITIONING SYSTEMS, 2012 EDITION.
J. NFPA 96 - COMMERCIAL COOKING EQUIPMENT, 2011 EDITION.
K. NFPA 99 - HEALTH CARE FACILITIES CODE, 2012 EDITION.
L. NFPA 105 - SMOKE DOORS, 2010 EDITION.
M. NFPA 110 - EMERGENCY POWER SYSTEMS, 2010 EDITION.
N. NFPA 241 - CONSTITUTION AND DEMOLITION, 2009 EDITION.
FIRE SPRINKLER SYSTEM:
1. THE COMBINATION STANDPIPE AND FIRE SPRINKLER SYSTEM WAS DESIGNED TO NFPA 13 AND NFPA 14.
2. QUICK RESPONSE TYPE SPRINKLERS ARE INSTALLED THROUGHOUT MOST OF THE BUILDING. STANDARD RESPONSE TYPE SPRINKLERS ARE INSTALLED IN THE ELEVATOR MACHINE ROOMS (NFPA 13- 3.6.4.8).
3. SPRINKLERS WERE INSTALLED IN LIGHT HAZARD AREAS INCLUDING; CORRIDORS, OFFICES, PATIENT CARE AND PATIENT SLEEPING ROOMS AT LIGHT HAZARD 0.10 GPM/1500 SQ. FT. DENSITY. MAXIMUM PROTECTION
AREA OF 225 SQ. FT. (NFPA 13- TABLE 11.2.3.1.2).
4. SPRINKLERS WERE INSTALLED IN ORDINARY HAZARD GROUP I AREAS INCLUDING; LABORATORIES (WITHOUT FLAMMABLE LIQUIDS), MECHANICAL EQUIPMENT ROOMS, ELECTRICAL SWITCH GEAR ROOMS, REPAIR
SHOPS AND STORAGE ROOMS UNDER 250 SQ. FT. AT A 0.15 GPM/1500 SQ. FT. DENSITY. MAXIMUM PROTECTION AREA OF 150 SQ. FT. (NFPA 13- TABLE 11.2.3.1.2).
5. SPRINKLERS WERE INSTALLED IN ORDINARY HAZARD GROUP II AREAS INCLUDING GENERAL STORAGE ROOMS OVER 250 SQ. FT. AND LABORATORIES (WITH THE USE OF FLAMMABLE LIQUIDS) AT A 0.20 GPM/1500 SQ.
FT. DENSITY.
6. MAXIMUM DISTANCE FROM SPRINKLERS TO WALLS FOR STANDARD SPRAY SPRINKLERS SHALL NOT EXCEED 7'-6" (NFPA 13-8.6.3.2.1). MAXIMUM DISTANCE FROM SPRINKLERS TO WALLS FOR STANDARD SPRAY
SPRINKLERS IN SMALL ROOMS (800 SQ. FT. MAXIMUM) SHALL NOT EXCEED 9' FROM ANY SINGLE WALL (NFPA 13-8.6.3.2.4).
7. SPRINKLERS SHALL BE INSTALLED UNDER FIXED OBSTRUCTIONS (I.E. DUCTWORK) OVER 4' WIDE (NFPA 13- 8.10.6.3.2). THE WIDTH OF DUCT INSULATION NOT A FACTOR FOR SPRINKLERS INSTALLED PRIOR TO THE
2013 EDITION ON NFPA 13. SPRINKLERS NOT REQUIRED UNDER NON COMBUSTIBLE OBSTRUCTIONS OVER 4' WIDE WHERE THE BOTTOM OF THE OBSTRUCTION IS A MAXIMUM 24" ABOVE THE FLOOR (NFPA 13- 8.5.5.3.1).
8. SPRINKLERS SHALL BE INSTALLED A MAXIMUM 12" BELOW A CEILING OR FLOOR/ROOF DECK (NFPA 13- 8.6.4.1.1.1) OR A MAXIMUM 22" BELOW A FLOOR/ROOF DECK WITH STRUCTURAL MEMBER OBSTRUCTIONS (NFPA 13- 8.6.4.1.2).
9. SHELVING ON A WALL OR SHELVING AGAINST A WALL INCLUDING STORAGE THEREON SHALL BE PERMITTED TO EXTEND WITHIN THE 18" SPRINKLERS CLEARANCE BELOW CEILING SPRINKLER DEFLECTORS (NFPA 13- 8.5.6.1).
10. WHERE THE 18" CLEARANCE BETWEEN SPRINKLERS AND SHELVING STORAGE CANNOT BE MAINTAINED, SPRINKLERS SHALL BE INSTALLED IN EVERY AISLE (NFPA 13- 8.15.9(2)).
11. CEILING MOUNTED OBSTRUCTIONS (I.E. PATIENT LIFT TRACKS) WITHIN THE 18" SPRINKLER DISCHARGE CLEARANCE ARE PERMITTED PER NFPA 13 TABLE 8.6.5.1.2 AND FIGURE 8.6.5.1.2(a).
12. FLOOR MOUNTED OBSTRUCTIONS (I.E. ROOM DIVIDERS OR SHELVING) WITHIN THE 18" SPRINKLER DISCHARGE CLEARANCE ARE PERMITTED PER NFPA 13 TABLE 8.6.5.2.2 AND FIGURE 8.6.5.2.2.
SUITES:
1. SUITES ARE UTILIZED TO ILLUSTRATE AREAS WITH THE SAME FUNCTION, USE OF HALLWAYS OR
AISLES AND TO DEFINE THE END OF PUBLIC EXIT CORRIDORS. NO EXIT SIGNS OUTSIDE OF THE
SUITE MAY DIRECT OCCUPANTS INTO A SUITE TO REACH AN EXIT.
2. HEALTH CARE OCCUPANCY SUITES ARE REGULATED BY FUNCTION AND SIZE.
3. HEALTH CARE OCCUPANCY PATIENT SLEEPING SUITES:
A. SINGLE EXIT SUITE - 1,000 SQ. FT. (NFPA 101 -19.2.5.7.2.2)
B. MULTI EXIT SUITE - 5,000 SQ. FT. (NFPA 101 - 19.2.5.7.2.3.A)
C. MULTI EXIT SUITE WITH STANDARD RESPONSE SPRINKLERS OR COMPLETE SMOKE DETECTION
- 7,500 SQ. FT. (NFPA 101 - 19.2.5.7.2.3.B)
D. MULTI EXIT SUITE WITH DIRECT VISUAL SUPERVISION, QUICK RESPONSE SPRINKLERS AND
COMPLETE SMOKE DETECTION - 10,000 SQ. FT. (NFPA 101 - 19.2.5.7.2.3.C)
4. PATIENT CARE NON - SLEEPING SUITES:
A. SINGLE EXIT SUITE - 2,500 SQ. FT. (NFPA 101 - 19.2.5.7.3.1.B)
B. MULTI EXIT SUITE - 10,000 SQ. FT. (NFPA 101 - 19.2.5.7.3.3)
5. HEALTH CARE OCCUPANCY NON - PATIENT - CARE SUITES FOLLOW THE TRAVEL DISTANCE
REQUIREMENTS AS LISTED IN TABLE A.7.6 OF NFPA 101.
6. SUITES IN OTHER OCCUPANCIES ARE NOT REGULATED IN SIZE BUT STILL FOLLOW THE TRAVEL
DISTANCE REQUIREMENTS AS LISTED IN TABLE A.7.6 OF NFPA 101.
FIRE ALARM SYSTEM:
1. THE FIRE ALARM SYSTEM WAS DESIGNED TO OLDER EDITION OF NFPA 72,
NATIONAL FIRE ALARM CODE.
2. PRIVATE MODE BUILDING OCCUPANT NOTIFICATION IS INSTALLED PER
SECTIONS 19.3.4.3.1 AND 9.6.3.6.3 OF NFPA 101-2012 EDITION.
3. PRIVATE MODE AUDIBLE DEVICES (SPEAKERS) ARE INSTALLED IN
CORRIDORS AND LARGER ROOMS OR SUITES PER SECTION 18.4.4.1 OF
NFPA 72- 2010 EDITION.
4. PRIVATE MODE VISIBLE DEVICES (STROBES) ARE INSTALLED AT
REDUCED QUANTITY AND SPACING PER SECTION 18.6 OF THE NFPA 72-
2010 EDITION.
5. STROBE CIRCUITS ARE REQUIRED TO BE SYNCHRONIZED IN
ACCORDANCE WITH SECTION 18.5.4.3.2(3) OF NFPA 72-2010 EDITION.
6. TYPICAL SMOKE DETECTORS HAVE A 21 FT. RADIUS OF COVERAGE AREA
(NFPA 72- 17.7.3.2.3.1)
7. SMOKE DETECTORS THAT ARE CONNECTED TO THE BUILDING FIRE
ALARM SYSTEM AND LOCATED ON BOTH SIDES OF SMOKE/FIRE DOORS
MAY BE SPACED AT MAXIMUM 21' RADIUS FOR DOOR RELEASE SERVICE
(NFPA 72- 17.7.5.6.1) SMOKE DETECTORS NOT CONNECTED TO THE
BUILDING FIRE ALARM SYSTEM AND USED EXCLUSIVELY FOR SMOKE/FIRE
DOOR RELEASE SHALL BE LOCATED AND SPACED PER NFPA 72- 17.7.5.6.
8. CEILINGS WITH BEAM DEPTHS OF LESS THAN 10% OF CEILING HEIGHT
SHALL BE CONSIDERED A SMOOTH CEILING FOR SMOKE DETECTOR
COVERAGE. CEILINGS WITH BEAM DEPTHS GREATER THAN 10% OF
CEILING HEIGHT SHALL HAVE REDUCED SMOKE DETECTOR SPACING
COVERAGE (NFPA 72- 17.7.3.2.4.2).
9. SMOKE DETECTORS SHALL BE LOCATED ON THE CEILINGS THE BOTTOM
OF BEAMS OR MAXIMUM 12" DOWN FROM THE CEILING TO TOP OF THE
DETECTOR (NFPA 72- 17.7.3.2.1).
10. SMOKE DETECTORS SHALL NOT BE LOCATED DIRECTLY IN THE AIR
STREAM OF SUPPLY AIR REGISTERS (NFPA 72- 17.7.6.3.2).
OCCUPANCY TABLE
Building No. Floor Health Care Ambulatory Health Care Business Industrial Dormitory Total 1 9 0 0 0 14,152 0 14,152
1 8 0 0 0 15,945 0 15,945
1 7 0 0 71,945 0 0 71,945
1 6 71,943 0 0 0 0 71,943
1 5 37,325 34,606 0 0 0 71,931
1 4 71,926 0 0 0 0 71,926
1 3 0 0 0 110,226 0 110,226
1 2 79,344 66,264 0 0 0 145,608
1 1 92,036 73,216 0 0 0 165,252
1 Ground 0 0 151,508 15,341 0 166,849
TOTAL 352,574 174,086 223,453 155,664 0 905,777
CODE SUMMARY AND
OCCUPANCY TABLE
X-02
LIFE SAFETY
SITE NAME/ADDRESS
REVISIONS: NUMBER DATE
ENGINEERS
Approved: Project Director Location
Issue Date
Drawing Title Project Title
Building Number
Drawing Number
Dwg.
Project Number
139 Old Creek Road Palos Park, IL 60464 and 12200 Bunya Lane Ruther Glen, VA 22546 Tel: 703-477-5928 Email: dale.wheeler@systechfire.com Checked By
DRW / JSW
Drawn By
TCG07/12/2023 of 13
J.L. McCLELLAN VAMC
STATEMENT OF CONDITIONS
DOCUMENTATION
LITTLE ROCK, ARKANSAS
Dept. of Veterans Affairs Medical Center 4300 W. 7th Street Little Rock, Arkansas 72205
GB172-JLM
STORAGE
GB171-JLM
SURGERY
GB174-JLM
SURGERY
GB173-JLM
OFFICE
GB177-JLM
SHOWER/DRESSING
GB178-JLM
RESTROOM
GB176-JLM
CLEAN CAGE STORAGE
GB191-JLM
COMP. ROOM
GB190A-JLM
WALK-IN REF.
GB190-JLM
NECROPSY
GB179-JLM
QUAR. WARD
GB166-JLM
STORAGE
CG17-JLM
CORRIDOR
GB170-JLM
SCRUB
GB168-JLM
STORAGE
GB162-JLM
WOMEN'S BR
GB156-JLM
LOUNGE
GB160-JLM
VEST.
GB161-JLM
LOCKERS
GB158-JLM
MEN'S LCKR106
GB159-JLM
MEN'S BR
GB152-JLM
STORAGE
GB154-JLM
STORAGE
C G
-J
LM
C
O R
R
ID
O R
GB153-JLM
ANIMAL WARD
GB151-JLM
ANIMAL WARD
GB192-JLM
CAGE SANITIZING
GB150-JLM
ANIMAL WARD
GB149-JLM
ANIMAL WARD
GB148-JLM
ANIMAL WARD
GB146-JLM
ANIMAL WARD
GB155-JLM
JANITOR
C G
-J
LM
C
O R
R
ID
O R
CG16-JLM
CORRIDOR
GB157-JLM
VEST.
GB163-JLM
FREEZER/STOR.
GB164-JLM
PROCED. LAB.
GB165-JLM
STORAGE
GB167-JLM
STORAGE
GB180-JLM
QUAR. WARD
C G
-J
LM
C
O R
R
ID
O R
GB144A-JLM
WALK-IN REF.
GB181-JLM
AIRLOCK
CG19-JLM
CORRIDOR
GB195-JLM
STORAGE
GB193-JLM
STORAGE
GB196-JLM
STORAGE
GB194-JLM
RECEIVING RM
GB186-JLM
QUAR. WARD
GB185-JLM
QUAR. WARD
CG14-JLM
CORRIDOR
GB147-JLM
ANIMAL WARD
GB145-JLM
ANIMAL WARD
GB116-JLM
JANITOR
GB117-JLM
NPHRLGY LAB. 2
GB118-JLM
BIOMED. LAB.
GB112-JLM
GRNTLGY RSRCH LAB. 5
GB106-JLM
LABORATORY
CG9C-JLM
CORRIDOR
GB108-JLM
TELEPHONE
GB109-JLM
COMP. ROOM
GB110-JLM
ELECTRIC
GC104-JLM
BIOMED. LAB.430
CG21-JLM
CORRIDOR
GC105-JLM
RESEARCH LABORATORY
GC126-JLM
JANITOR 317
CG9B-JLM
CORRIDOR
GB107-JLM
SIGNAL
GB119-JLM
NEPHROLOGY LAB. 3
CG11-JLM
CORRIDOR
GB120-JLM
LABORATORY
GB127-JLM
OFFICE
GB128-JLM
OFFICE
GB130-JLM
MYCOBACTERIOLOGY LAB.
GB133-JLM
TELEPHONE
GB132-JLM
SIGNAL
GB134-JLM
ELECTRIC
GB122-JLM
LABORATORY
GB123-JLM
STORAGE
GE106-JLM
WOMEN'S RR
GB121-JLM
OFFICE
GB114-JLM
STORAGE
CG8-JLM
CORRIDOR
GB100-JLM
LABORATORY
GC100-JLM
LABORATORY
GC102-JLM
CENTRIFUGE
CG9A-JLM
CORRIDOR
GC125-JLM
RESEARCH OFFICE
GC117-JLM
VESTIBULE
GC120-JLM
MEN'S RR
GC118-JLM
LOUNGE
GC108-JLM
COMP. ROOM
C G
-J
LM
C
O R
R
ID
O R
GC115-JLM
JANITOR
GC101-JLM
LABORATORY
GE102-JLM
POLICE STORAGE
GE101-JLM
POLICE STORAGE
GE104-JLM
WOMEN'S LOUNGE
GE105-JLM
WOMEN'S LOCKERS
GC110-JLM
DARK ROOM
CG23-JLM
CORRIDOR
GC107-JLM
DARK ROOM
GC111-JLM
STOR. RM B
GB139-JLM
CONFERENCE ROOM
CG38C-JLM
VESTIBULE
GB143A-JLM
GE111-JLM
MEN'S RESTROOM
GE123-JLM
ELECTRIC
GE108-JLM
JANITOR
GE109-JLM
CART WASH
GD129-JLM
ENERGY PLANT
GD133-JLM
ENERGY PLANT
GD132-JLM
MEN'S RR45
GD131-JLM
MEN'S LOCKER
GD117-JLM
PHARMACY STORAGE
GD116-JLM
LOCKSMITH
GD116A-JLM
CLOSET
GD114A-JLM
PAINT ROOM
GD114B-JLM
CARPENTRY SHOP
CG36-JLM
CORRIDOR
GD114F-JLM
PLUMBING SHOP
GD114G-JLM
EQUIPMENT REPAIR SHOP
GD114H-JLM
EQUIPMENT REPAIR SHOP
C G
A-
JL
M
C O
R R
ID
O
R
GC156-JLM
RESEARCH OFFICE
GC155-JLM
SURGICAL BIOCHEMICAL LABORATORY
CG29-JLM
CORRIDOR
GC154-JLM
STORAGE
GC109-JLM
CULTURE ROOM
GC112-JLM
MICROTOME ROOM B
GC134-JLM
STOR. ROOM A
CG25-JLM
CORRIDOR
GC131-JLM
ELECTRON MICROSCOPY
GC130-JLM
LEAD TECH. OFFICE
GC135-JLM
HEMATOPOIESIS LABORATORY
C G
-J
LM
C
O R
R
ID
O R
CG26-JLM
CORRIDOR
GC140-JLM
SIGNAL
GC139-JLM
TELEPHONE
GC138-JLM
ELECTRIC
GC141-JLM
MECH. ROOM
GC142-JLM
OFFICE
GC170-JLM
DIETETIC SPVSR OFFICE
GC171-JLM
CLOSET
CG32-JLM
CORRIDOR
GC172-JLM
OFFICE
GC174-JLM
JANITOR
GC176-JLM
MEN'S RR183
GC175-JLM
MEN'S LOCKER
GC173-JLM
DISHWASHING
GA104-JLM
BATHROOM
GA109-JLM
EMS STORAGE
GE100B-JLM
OFFICE
GE100A-JLM
OFFICE
GE100D-JLM
STORAGE
CG37B-JLM
CORRIDOR
GA101-JLM
SOILED LINEN
CG5-JLM
SERVICE ELEV. LOBBY
CG2-JLM
CORRIDOR
GA103A-JLM
VESTIBULE
GA103-JLM
LOUNGE
GC168-JLM
TRAY CART STORAGE
GA102-JLM
SPVSR BLDG MNGMNT
CG3-JLM
CORRIDOR
GA105-JLM
ELECTRIC
GA107-JLM
TELEPHONE
CG3A-JLM
CORRIDOR
GA106-JLM
SIGNAL
GC167-JLM
DIETETIC SERVICES
GC144-JLM
SPVSR OFFICE
GC129-JLM
RSRCH OFFICE
GC143-JLM
HEMATOLOGY
GC141A-JLM
WALK-IN REF.
CG27-JLM
CORRIDOR
CG28-JLM
CORRIDOR
GC148-JLM
OFFICE
GC137-JLM
RSRCH OFFICE
GC147-JLM
RADIATION BIOPHYSICS
GC149-JLM
ONCOLOGY LABORATORY
GC151-JLM
COMP. ROOM
GC145-JLM
STORAGE
GR2-JLM
WALK-IN REF.
GR3-JLM
WALK-IN FREEZER
CG30-JLM
CORRIDOR
GC162-JLM
NON-FOOD STORAGE
GC164-JLM
SOAP STORAGE
GC163-JLM
JANITOR
GC165-JLM
FOOD STORAGE
GC166-JLM
POT WASHING
GC189A-JLM
PHARMACY SERVICE
GA108-JLM
TRASH
CG4-JLM
CORRIDOR
GC190-JLM
VAULT
GE113B-JLM
OFFICE
GE113C-JLM
OFFICE
CG34-JLM
CORRIDOR
GC196-JLM
TELEPHONE EQUIPMENT
GC194-JLM
RESTROOM
GC193-JLM
CLOSET
GR1-JLM
WALK-IN REF.
GC161-JLM
SOILED UTILITY
GC160-JLM
RECEIVING
CG31A-JLM
CORRIDOR
GC177-JLM
JANITOR
GC184-JLM
DRUG INFO. LIB.
GC195-JLM
LOCKERS
GC183-JLM
MEN'S BR
GC182-JLM
MEN'S LOCKER
GD105-JLM
OFFICE
GD104-JLM
ELEC.
STORAGE
GD111-JLM
TELEPHONE
GD110-JLM
SIGNAL
GD112-JLM
ELECTRIC
GD113-JLM
SECRETARY1165
GD114D-JLM
BIOMEDICAL REPAIR SHOP
GC181-JLM
WOMEN'S BR
CG35-JLM
CORRIDOR
GC180-JLM
WOMEN'S LOCKER
GC158-JLM
LABORATORY
C G
-J
LM
C
O R
R
ID
O R
GC159-JLM
OFFICE
GC157-JLM
VASCULAR RESEARCH
GD101-JLM
DATA HEAD END
GE113-JLM
CLEAN/STERILE STORAGE
CG40-JLM
CORRIDOR
GE120-JLM
RESTROOM
GE114-JLM
JANITOR
GE122-JLM
VESTIBULE
GE121-JLM
PLUMBING
GE116-JLM
PRIMARY SWITCHGEAR
GE115-JLM
FAN ROOM & PLUMBING
CG39-JLM
CORRIDOR
GD136-JLM
CLEAN LINEN713
GD125-JLM
SPD STORAGE/ESS SUPPLY
CG37-JLM
CORRIDOR
GD126-JLM
SIGNAL
GD127-JLM
TELEPHONE
GD128-JLM
ELECTRIC
CG37A-JLM
CORRIDOR
GC191-JLM
MECH. RM
GD114E-JLM
ELECTRICAL SHOP
GC169-JLM
DIETETIC'S
CG7-JLM
CORRIDOR
GB105A-JLM
SECRETARY
GB105C-JLM
RSRCH OFFICE
GB125-JLM
STORAGE
GC189-JLM
PHARMACY SERVICE
GE107A-JLM
SPD TRAINING ROOM
GE107-JLM
SOILED, RECEIVING
& DECON AREA
GC197-JLM
TELEPHONE EQUIPMENT
GE101A-JLM
MEN'S RR
SG2-JLM
STAIR 2
C
C
SG1-JLM
STAIR 1
CG36A-JLM
CORRIDOR
SG9-JLM
STAIR 9
C C
C C
C
CC
C C
SG5-JLM
STAIR 5
SG7-JLM
STAIR 7
SG3-JLM
STAIR 3
SG8-JLM
STAIR 8
SG4-JLM
STAIR 4
C
C C C
C
C C C
CC
C
GB126A-JLM
STERILIZER
GB111-JLM
WALK-IN REF.
GB123A-JLM
STORAGE
GB154A-JLM
DARK ROOM
GC132-JLM
WALK-IN REF.
GD114-JLM
STORAGE
GA104A-JLM
DRSSNG/SHOWER
GD138-JLM
ELEV. SHAFT
GD139-JLM
POWER ROOM
GD140-JLM
CONTROL ROOM
GE126-JLM
STORAGE
GD130A-JLM
HALL
CG10-JLM
CORRIDOR
CG9D-JLM
CORRIDOR
CG38A-JLM
CORRIDOR
CG36B-JLM
CORRIDOR
CG38-JLM
CORRIDOR
CG38B-JLM
CORRIDOR
CG10A-JLM
CORRIDOR
CG10B-JLM
CORRIDOR
CG12-JLM
CORRIDOR
CG12B-JLM
CORRIDOR
95 C G
A-
JL
M
C O
R R
ID
O
R
CG33-JLM
CORRIDOR
CG32A-JLM
CORRIDOR
SUB H
2000 KVA
1000 KVA
SUB D
SUB C
1000 KVA
SUB B
1500 KVA
SOLN.
STOR. (*NIC)
PASS THRU
REFRIGERATOR
GEM MODEL WP-NT-3D
SOLN.
STOR.
3 - DOOR FREEZER
(NIC)
* NOT TO SCALE
(CARBON DIOXIDE)
GAS MANIFOLD
COMPRESSED
ROOF
LADDER
ACCESS
FD
GF104-JLM
LAB #6
GF105-JLM
LAB #5
GF106-JLM
LAB #4
GF107-JLM
LAB #3
GF111-JLM
OFFICE #1
GF112-JLM
OFFICE #2
GF113-JLM
OFFICE #3
GF114-JLM
LAB #2
GF115-JLM
LAB #1
GF116-JLM
TOILET
GF123-JLM
BL-3 LAB #1
GF122-JLM
BL-3 LAB #2 80
GF117-JLM
COLD ROOM
GF118-JLM
FREEZER
GF119-JLM
WARM RM
GF110-JLM
TISSUE CULTURE LAB #2
GF125-JLM
TISSUE CULTURE LAB #1
GF108-JLM
CLEAN SUPPORT LAB
GF135-JLM
HAC
GF102-JLM
MEN
GF103-JLM
WOMEN
GF101-JLM
LOUNGE
GF133-JLM
OFFICE #8
GF132-JLM
OFFICE #7
GF134-JLM
RECEPTION
GF128-JLM
RECEPTION
GF131-JLM
OFFICE #6
GF130-JLM
OFFICE #5
GF129-JLM
OFFICE #4
GF127-JLM
LAB #8
GF126-JLM
LAB #7
GF138-JLM
COMM
GF140-JLM
ELEC
GF137-JLM
STORAGE
GF139-JLM
MECHANICAL ROOM
GF142-JLM
HAZARDOUS STORAGE
GF141-JLM
HAZARDOUS STORAGE
GF136-JLM
MECH
GF124-JLM
DIRTY SUPPORT LAB
GF124A-JLM
CYLINDER STORAGE
GF121-JLM
ANTE
GF120-JLM
DARK ROOM
CG45-JLM
CORRIDOR
CG46-JLM
CORRIDOR
CG43-JLM
CORRIDOR
CG42-JLM
CORRIDOR
CG41-JLM
CORRIDOR
C G
-J
LM
C
O R
R
ID
O R
DOOR
No. 23
No. 21A
DOOR
No. 20
DOOR
No. 19
DOOR
No. 18
DOOR
No. 17
DOOR
No. 16
DOOR
No. 15
DOOR
No. 14
DOOR
No. 13
DOOR
No. 12
DOOR
No. 11
DOOR
No. 10
DOOR
No. 09
DOOR
No. 08
DOOR
No. 07
DOOR
No. 06
DOOR
No. 05
DOOR
No. 04
DOOR
CRU-1
CONC.
PAD
GF143-JLM
MECHANICAL ROOM
SG10-JLM
STAIR 10
CG47-JLM
CORRIDOR
GF144-JLM
R.O. ROOM
No. 25
DOOR
No. 26
DOOR
GE107B-JLM
DECON ANTE
GE112A-JLM
STER. EQ. ACCESS
EX
EX
EX
EX
EX
EX
EX
EX
EX
EP
EP
EP
EP
OPEN DOCK
EX
EP
EX
EX
CG45A-JLM
VESTIBULE
K Type
EX
A
FZ
GC-1
FZ
GC-2
FZ
GC-2
FZ
GD-1
FZ
GC-3
FZ
GC-4
FZ
GC-1
FZ
GB-1
FZ
GF
FZ
GB-2
FZ
GE-2
FZ
GE-2
FZ
GE-1
FZ
GD-2
SPECIAL PURPOSE
INDUSTRIAL OCCUPANCY
BUSINESS
OCCUPANCY
K
C H
AS
E
ELEV. S-4
STAFF ONLY
ELEV. S-5
STAFF ONLY
ELEV. S-3
RESTRICTED
USE
ELEV. S-2
STAFF ONLY
ELEV. S-1
STAFF ONLY
ELEV.
P-4
P-5
ELEV.
ELEV.
P-3
ELEV.
P-2
ELEV.
P-1
GD135-JLM
INCINERATOR
ROOM
GD130-JLM
BOILER PLANT
OFFICE
GD119-JLM GAS
STORAGE
GD103-JLM
WAREHOUSE
GD118-JLM EMERG.
OXYGEN MANIFOLD ROOM
GD123-JLM
ELECTRICAL
POWER ROOM
GD102-JLM
CLEAN STORAGE
GD120-JLM
CHIEF SPD
OFFICE
GD121-JLM
SPD OFFICE
ADMINISTRATION 493
GD122-JLM
SPD EQUIPMENT
STORAGE ISSUE
GD124-JLM
ACETIC ACID ROOM
GD137-JLM
SOILED
UTILITY
GE125-JLM
MECH. ROOM/
STORAGE
GE119-JLM
CART LIFT &
MACH. ROOM
GE118-JLM
BUDGET ANALYST
NX EQUIP. SECTION164
GE110-JLM
WOMEN'S
RESTROOM
GB143-JLM
BUDGET
ANALYST
GB136-JLM
MYCOBACTERIOLOGY
LABORATORY
GB135-JLM
PLMNRY
MYCOBCTRLGY LAB.
GB131-JLM
CHEMICAL
BIOPHYSICS LAB.124
GB137-JLM
RESEARCH
OFFICE
GB126-JLM
MYCOBACTERIOLOGY
LAB.
GB129-JLM
MYCOBACTERIOLOGY
LAB.
GB125A-JLM
MYCOBCTRLGY
LAB. CLEAN RM
GB189-JLM
VET. MED.
OFFICER
GB187-JLM
SPVSR VET.
MED. UNIT
GB105-JLM
GRECC RESEARCH
OFFICE
GC106-JLM
VASCULAR SURGERY
RESEARCH
GC124-JLM
REAP ENDCRNLGY
LAB.
GB102-JLM
RSRCH
OFFICE
GE100C-JLM
ENVIRONMENTAL
SRVCS
CG1-JLM
PUBLIC
ELEV. LOBBY
GA110-JLM
EMS
STORAGE
GB124-JLM
NEPHROLOGY
LABORATORY 1
GB141-JLM
BIOMED.
RSRCH
GB142-JLM
MED RSRCH
ADMN
GB138-JLM
MED RESEARCH
ADMIN
GB140-JLM
MED RESEARCH
ADMIN
GF100-JLM
CONFERENCE
ROOM
GF109-JLM
ULTRA
FREEZER RM
GB175-JLM
POST-OP
WARD
GB169-JLM
SURGICAL
WRKRM/SUPPLY
GB184-JLM
DGNSTC/TRTMNT
WARD
GC103-JLM
CHEMISTRY
LABORATORY
GC123-JLM
REAP ENDOCRINOLGY
LABORATORY
GC122-JLM
RESEARCH
OFFICE
GC121-JLM
CELL RESEARCH
LABORATORY
GC116-JLM
REAP ENDOCRINOLOGY
LAB.
GB101-JLM
GASTROENTEROLOGY
LAB.
GB103-JLM
GERIATRICS
LABORATORY
GB115-JLM
GERONTOLOGY
RSRCH LAB. 7
GB104A-JLM
GRNTLGY
RESEARCH LAB. 2
GB104-JLM
GERONTOLOGY
RESEARCH LAB. 7
GB113-JLM
GRNTLGY
RESEARCH LAB. 6
GB105D-JLM
RSRCH
OFFICE
GB105E-JLM
RSRCH
OFFICE
GB105B-JLM
RSRCH
OFFICE
GC114-JLM
ELECTRON
MICROSCOPY
FINISH ROOM
GC113-JLM
ELECTRON
MICROSCOPY PREP.
ROOM
GC133-JLM
MICROTOME
ROOM A
GC128-JLM
HEMATOPOIESIS
LABORATORY
GC136-JLM
GRNTLGCL
ENDCRNLGY LAB.
GC146-JLM
INFECT. DISEASE
LAB. PLMNRY
GC152-JLM MED.
RSRCH DEPT.
CORE EQUIP.
GC150-JLM
ONCOLOGY
LABORATORY B
GC188-JLM
CENTRAL RECEIVING/
STORAGE & ORDERING
GC178-JLM
INVENTORY
FORMULARY
MNGMNT OFFICE
GC192-JLM
PHARMACY
CONF. RM.
GC187-JLM
CLINICAL OA
& ED COORD.
GC185-JLM
RESIDENT'S
OFFICE
GC153-JLM
ANESTHESIOLOGY
RESEARCH LAB.
GD114C-JLM
BIOMEDICAL
REPAIR SHOP
GD107-JLM
BIOMED. ENG.
SPRVSR
GD108-JLM
BIOMEDICAL
SPRVSR
GD109-JLM
BREAK/
CONFERENCE
ROOM
GD106-JLM
BIOMEDICAL
OFFICE
GE113BA-JLM
SPRVSR MSD
SECTION
GE112-JLM
PREPARATION,
ASSEMBLY & STERILIZATION
GB144-JLM
FEED/BED
STOR.
GB182-JLM
INFECT.
DISEASE WARD
GB188-JLM
EDITORIAL
ASSIST.
GB183-JLM
INFECT.
DISEASE
GC127-JLM
GLASSWARE
WASHING & STER.
GD134-JLM
EMERGENCY
GENERATORS
GE117-JLM
PRIMARY
TRANSFORMER
GE124-JLM
ENTRY/
STORAGE
SITE NAME/ADDRESS
REVISIONS: NUMBER DATE
ENGINEERS
Approved: Project Director Location
Issue Date
LITTLE ROCK, ARKANSAS
07/12/2023
Drawing Title Project Title
Building Number
Drawing Number
Dwg. of 13
Project Number
139 Old Creek Road Palos Park, IL 60464 and 12200 Bunya Lane Ruther Glen, VA 22546 Tel: 703-477-5928 Email: dale.wheeler@systechfire.com Checked By
DRW / JSW
Drawn By
TCG
Dept. of Veterans Affairs Medical Center 4300 W. 7th Street Little Rock, Arkansas 72205
J.L. McCLELLAN VAMC
STATEMENT OF CONDITIONS
DOCUMENTATION
PARTITION LEGEND
2 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE ZONE BARRIER
SMOKE ZONE BARRIER
1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
SYMBOLS LIST
HORIZONTAL EXIT PASSAGEWAY
EXIT
EXIT PASSAGEWAY
LINEN CHUTE
TRASH CHUTE
EP
TC
EX
HE
AREA OPEN TO CORRIDOR WITH SMOKE DETECTION
AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED
SUITE DESIGNATION
1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
SPRINKLER / FIRE SMOKE ZONE
NON-RATED SMOKE PARTITION
LC
GROUND FLOOR
BUILDING 1
LIFE SAFETY
N FULLY SPRINKLERED
BUSINESS OCCUPANCY
GROUND FLOOR
BUILDING 1
GAS STG. ROOM OVER 3000 CU. FT OF COMB. GAS MECH VENT. &
ELECT. PROTECTION PROVIDED AS REGULATED BY SECT. 5.1.3.3 OF
NFPA 99
KEY NOTES:
A
SUITE DESCRIPTIONS
SUITE NUMBER SUITE NAME SUITE SIZE TYPE OF SUITE
9,292 Sq. Ft.
EXIT NUMBER
31 NON PATIENT CAREENGINEERING SHOPS SUITE
LS-0G
EKG
HOLTER ROOM
1C107B
COUNTER
H O
O D
COUNTER
IPLI
PANEL
COUNTER
C O
U N
TE
R
LOCKER/CAB.
DDC
(ABOVE) COMPUTER EQUIPMENT
POWER
MODULE
IXPO
OPENING IN WALL ABOVE
METAL COVER OVER WALL
CHASE FOR CABLES
POWER
FILTERS
EQUIP.
ON FLOOR
LIEBERT
CRU
COMP.
EQUIP.MRI MAIN
DISC. CONTROL
ED
G
E O
F C
O M
PU
TE
R F
LO
O
R
WATER
FOUNTAIN
X- R
AY
R
EA
D
ER
X-
R
AY
R
EA
D
ER
LO
C
KE
R
S
LC
KRS METAL COVER
OVER WALL CHASE
FOR CABLES
E.
J.
LO
C
KE
R
S
SHELVES
E.
J.
COUNTER
LASER
IMAGER
MRI
EDGE OF
REMOVABLE
FLOOR
MOP
SINK
FU
R
R D
O W
N
CHASE
FOUNTAIN
DISCS.
AIR COMP.
ON METAL
FIRE
PIPE
WORK STATION
CHASE
COUNTER
COUNTER
CO
WORK
STATIO
N
WORK
STATIO
N
COUNTER
ST
AT
IO
N
ST
AT
IO
N
COUNTER
W O
R K
W O
R K
COUNTER
ST
AT
IO
N
ST
AT
IO
N
COUNTER
W O
R K
W O
R K
CO
COUNTER
WORK
STATION
WORK
STATION
CHASE
WORK
STATION
STATION
WORK
WORK
STATION
C O
U N
TE
R
C O
U N
TE
R
WORK
STATION
STATIO
N
COUNTER
WORKCOUNTER
WORK
STATIO
N
WORK
STATIO
N
WORK
WORK
C O
U N
TE
R
STATION
STATION
CO
W O
R
K STATIO
N
R
EC
EP
TI
O N
IS
T
W
IN
D O
W
C O
U N
TE
R
CO
ANNUNCIATOR
PANEL
C H
AS
E
C O
U N
TE
R
C O
U N
TE
R
CO
C O
U N
TE
R
COUNTER
W O
R K
ST
AT
IO
N
COUNTER
W O
R K
ST
AT
IO
N
R
EC
EP
TI
O N
IS
T
W
IN
D O
W
CHASE
COUNTER
PANEL IL8
CHASE
FORMER
TRANS-
PANEL
IEL4
PANEL
IEH4
CHASE
SLIDING
WINDOW
W O
R K
ST
AT
IO
N
SIGNAL
CHASE
FIRE
ALARM
CAB.ACCESS
PANEL J-BOX
EQUIP.
WATER
FOUNTAIN
TELE.
EQUIP.
TRANS-
FORMER
PANEL
1H8
C O
U N
TE
R
COUNTER
UP
DOWN
FIRE
PIPES
EQUIP.
FIREFIGHTER
EMERGENCY
TELEPHONE
CONTROL
CENTER
HANDRAIL
(TYP)
C O
U N
TE
R
C O
U N
TE
R
C O
U N
TE
R
WORK
STATION
WORK
STATION
WORK
STATION
COUNTER
WORK
STATION
WATER
SINK
MOP
FRAME
C H
AS
E
CHASE
HOLDER
SPECIMEN
COUNTER
SINK
MOP
C H
AS
E
P-4
ELEV.
ELEV.
P-5
ELEV.
P-1
PA
Y
PH
O
N
ES
ELEV.
P-2
ELEV.
P-3
CO
CO
STAFF ONLY
ELEV. S-5
STAFF ONLY
ELEV. S-4
STAFF ONLY
ELEV. S-1
FOUNTAIN
WATER
STAFF ONLY
ELEV. S-2
RESTRICTED
ELEV. S-3
USE
TRASH
CHUTE
ATM
LINEN
CHUTE
COUNTER
CHASE
CO
WALL
HEATER
ANNUNCIATOR
PANEL
CHASE
C O
U N
TE
R
COUNTERCOUNTER COUNTER COUNTER COUNTER
WORK STATION
SH
EL
VE
S
WORK STATION
W O
R K
ST
AT
IO
N
SH
EL
VE
S
SH
EL
VE
S
SH
EL
VE
S
SH
EL
VE
S
TELE.
EQUIP.
TRANS-
FRMRS
WORK STATION
CO
CHASE
SLIDING
DOORS
PIPES
UP
DOWN
IRON
GATE
FIRE
SLIDING
DOORS
SHOWER
STEP
OVER
BENCH FD
C H
AS
E
C H
AS
E
OVERHEAD
CANOPY
COUNTER
DUMB
WAITER
W O
R K
ST
AT
IO
N
W O
R K
ST
AT
IO
N
W O
R K
ST
AT
IO
N
SH
EL
VE
S
SHELVES
SHELVES
SHELVES
C O
U N
TE
R
COUNTER
C O
U N
TE
R
CO
COUNTER
WORK STATION
LO
C
KE
R
S
FIRE
CAB.
SIGNAL
EQUIPMENT
CO
UP
DOWN
FIRE
PIPES
CHASE
CHASE
W O
R K
ST
AT
IO
N
CHASE
SLIDING
DOORS
CHASE
CO
C H
AS
E
ACCESS
PANEL
TELE.
EQUIP. J-BOX
POWER
CAB.
WATER
VALVE
CAB.
EXIT
WATER
FOUNTAIN
C H
AS
E
C O
U N
TE
R
C H
AS
E
DISC.
PANEL
IH3
COUNTER
PANEL
IPLI
CAB.
PANEL
1EL2PANEL
IL3
SINK
MOP
FURRDOWN
FIRE
PIPES
UP
DOWN
UP
ACCESS
PANEL
PANEL
IEH2
C H
AS
E
H O
O D
COUNTER
PANEL
1CL1
CO
COUNTER
CO
CONTROL
EQUIP.
FIRE
CAB.
SIGNAL
EQUIP.
TELE.
PANEL
IPL2
FD
SLIDING
DOORS
PANEL
IPL3
UNLABELED
PANEL
CHASE
C O
U N
TE
R
C O
U N
TE
R
COUNTER
C O
U N
TE
R
C O
U N
TE
R
STATION
COUNTER
WORK
WORK
STATION
WORK
STATION
COUNTER
COUNTER
WORK
STATION
WORK
STATION
STATION
WORK
C O
U N
TE
R
UP
FIRE
PIPES
DOWN
COUNTER
FOOD SERVICE
COUNTER
W O
R K
COUNTER
ST
AT
IO
N
WORK
STATION
W O
R K
ST
AT
IO
N
C O
U N
TE
R
FOOD SERVICE COUNTER
FD
BREAKERS
FIRE SUPPRESION
CABINET
FD
PANEL
IH9
PANEL
IQL4
J-BOX
FIRE
PANEL
COUNTER
PANEL
IHK
COUNTER
RESET
PANELS
GARBAGE
DISPOSALDISC.
C H
AS
E PANEL
IL9
PANEL
IDH3
DISCS.
FD
CO
FIRE N
TRANS-
FORMERS
FD
FD
EXTNGSHER
WALL
4'-6"
FD FD
TALL
DRY
CHEMICAL
HOLE
IN WALL
FO
O
D S
ER
VI
C E
C O
U N
TE
R
FD
FD
FD
CONTROLS
DISHWASHER
FD
CO
FO
O
D S
ER
VI
C E
C O
U N
TE
R
FD
FLOORSLEEVE
CO
FD
FD UP
DOWN
FIRE
PIPES
CO
FD FD
VE
N
T H
O O
D
FO
O
D S
ER
VI
C E
C O
U N
TE
R
FD FD
CO
FD
DISPLAY/REGISTER
PANEL
BREAKER
MOP SINK
BE
N
C H
CO
DISPLAY/REGISTER
CLST
ACCESS
PANEL
DUMB
WAITER
C O
N
VE
YO
R
DUMB
WAITER
C H
AS
E
PANEL
BREAKER
PANEL
TRANSFORMERS
IH6
C
LO
SE
T
C H
AS
E
C H
AS
E
SINK
MOP
STAIR
#3
CO
CO
XFRMRS
PANEL
PANEL 1L11
SIGNAL
EQUIP.
PANEL
PANEL IDHI
ALARM
PANEL
PANEL
ILIO
PANEL
1EL1
PANEL
IEH1
ILI
IHI
FIRE
CAB. TELE.
EQUIP.
PIPES
C H
AS
E
FIRE
DOWN
COUNTER
CONTROL IQLI
BREAKER
PANELS
BREAKER
PANELS
CONTROL
PANEL
CHASE BE
N
C H
BREAKER
PANELS
BREAKER
BENCH BREAKER
PANELS
SINK
MOP
BREAKER
PANELS
UNLABELED
PANEL
FD
BREAKER
PANEL
PANEL
DEVELOPER
TANKFIXER
TANK
FD FD
BE
N
C H
BREAKER
PANELS
WATER
FOUNTAIN
BE
N
C H
CHASE BE
N
C H
BREAKER
PANELS
CAB.
BREAKER
PANEL
TRANSFORMER
DISC.
ROTOR
CONTROL
UNIT
DOORS
FI
LE
S
PANEL
1QHX
CNTRL
PNL
PANEL
1LX1
CONNCECTION
HAZARD
INDICATOR
BREAKER
PANEL
C H
AS
E
COUNTER
FIRE
VALVE
HAZARD
INDICATOR
PANEL
C O
U N
TE
R
C H
AS
E
BN
C
H
PANEL
PANEL
VALVE
BOX
BREAKER
PANELS
X-RAY
C H
AS
E
ACCORDIAN
BREAKERCO
PANEL
PANEL
IH2
C O
U N
TE
R
ATS
J-BOX
DISC.
PANEL
IQHI
PANEL
IHXI
TRANS-
FRMRS
FIRE
CAB.
ELEC.
PANEL
C H
AS
E
PILOT
LIGHT
CONTROL
PANEL
FIRE
PIPES
UP
DOWN
TELE.
EQUIP. CHASE
C O
U N
TE
R
M C
C -4
CURB AROUND
ABOVE
EF-35
FI
LE
S
FI
LE
S
PLENUM
EF-36
INTAKE
SPIGOT
EF-37
BELT
GUARD
DUCTS
CONCRETE
EF-38
ELEC.
MOTOR
PADS
CONC.
DISC.
COUNTER
READER
X-RAY
CAB.
CONTROL
METAL STEPS
UP TO ROOF
UP
C O
U N
TE
R
WALL
HEATER
COUNTER
GYP. WALL
ORIGINAL
CONCRETE
X-RAY
READER
BLOCK
LEDGE
READER
X-RAY
COUNTER
BREAKER
PANEL
J-BOX
SIGNAL
PANEL
FIRE
IH7
LTNG
CNTCTR
CAB.
PANEL
IH7A
PANEL
EQUIP.
TELE. IL7A
PANEL
CONTROL
PANEL
TRANS.
PANEL
IL7
1B117-JLM
EXAM ROOM
1B115-JLM
OFFICE/
EXAM 123
1B118-JLM
OFFICE/EXAM
1B120-JLM
OFFICE/EXAM
1B122-JLM
EXAM ROOM
1B124-JLM
EXAM ROOM
1B125-JLM
EXAM ROOM
1B126-JLM
EXAM ROOM
1B127-JLM
EXAM ROOM
1B128-JLM
OFFICE/EXAM
1B133-JLM
EXAM ROOM
1B134-JLM
OFFICE/EXAM
1B136-JLM
STAFF
BREAKROOM
1B137-JLM
PUBLIC RR
1B139-JLM
TELE. CL.
1B140-JLM
CONSULT/
EXAM
1B138-JLM
SIGNAL CL.
1B173A-JLM
CANTEEN STORAGE
1B141-JLM
CONSULT/
EXAM
1B135-JLM
EXAM ROOM
1B132-JLM
EXAM
1B131-JLM
NURSE
STATION
1B130-JLM
EXAM
1B129-JLM
EXAM
1B123-JLM
CLEAN UTILITY
1B121-JLM
OFFICE/EXAM
1B175-JLM
DRESSING ROOM
1B119-JLM
OFFICE/EXAM
1B116-JLM
SOILED UTILITY
1B114-JLM
EXAM ROOM
1B172-JLM
WAITING ROOM
1B113-JLM
EXAM ROOM
1B108-JLM
EXAM ROOM
1B112-JLM
EXAM
1B111-JLM
EXAM
1B110-JLM
NURSE STN
1B109-JLM
EXAM
1B107-JLM
EXAM ROOM
1B104-JLM
EXAM ROOM
1B142-JLM
NURSE MGR
OFFICE
1B146-JLM
RESTROOM
1B145-JLM
EXAM ROOM
1B143-JLM
PROCEDURE
ROOM
1B144-JLM
RESTROOM
1B147-JLM
OFFICE/EXAM
1B148-JLM
EXAM ROOM
1B150-JLM
EXAM
1B151-JLM
EXAM
84 1B
2-
JL
M M
ED
. R
O O
M
1B153-JLM
MAS OFFICE 86
1B161-JLM
OFFICE
1B168-JLM
ELECTRIC
1B163-JLM
PUBLIC RR
1B162-JLM
EXAM
1B164-JLM
EXAM ROOM
1B165-JLM
EXAM
1B156A-JLM
RESTROOM
1B100-JLM
MEN'S RR
1B101-JLM
WOMEN'S RR
1B105-JLM
OFFICE/EXAM
1B106-JLM
EXAM ROOM
1B155-JLM
EXAM ROOM
1B154-JLM
NURSE'S STATION
1B157-JLM
OFFICE/EXAM
1B160A-JLM
ALCOVE
1B167-JLM
MULTIPURPOSE
ROOM
1B166-JLM
EXAM ROOM
1B156-JLM
WAITING ROOM
1B160-JLM
CHECK OUT DESK
1B159-JLM
RESTROOM
C13-JLM
CORRIDOR
1C140-JLM
TREATMENT
1C139-JLM
AUDIOLOGIST
1C137-JLM
SPEECH
PATHOLOGIST
1C136-JLM
OFFICE
C146-JLM
CORRIDOR
1C134-JLM
CLERK
1C135-JLM
CHIEF AUDIOLOGY,
SPEECH PATH.
1C133-JLM
CORRIDOR
1C138-JLM
WAITING ROOM 156
C148-JLM
CORRIDOR
C149-JLM
CORRIDOR
1C142-JLM
INSTRUMENT
CALIBRATION
1C146-JLM
ELECTRIC
1C145-JLM
SIGNAL
1C144-JLM
TELEPHONE
C145-JLM
CORRIDOR
1C147B-JLM
AURAL REHAB.208
1C147A-JLM
ENG. & HEARING
AID FITTING
1C147-JLM
HEAR AID
FITTING ROOM
C147-JLM
CORRIDOR
1A101-JLM
LABORATORY SVC.
C15-JLM
CORRIDOR
C14-JLM
SOUTH (RED) ATRIUM
1B177-JLM
DINING AREA
1B174-JLM
OFFICE
1B173-JLM
CANTEEN STORAGE
1E213A-JLM
RADIOLOGIST
1E214-JLM
READING
ROOM
1E158-JLM
OFFICES AND
COMPUTERS
1E132-JLM
SUPERVISOR
OFFICE
C182-JLM
CORRIDOR
1E213-JLM
PACS OFFICE
1E212-JLM
READING ROOM
1E216-JLM
STORAGE
1E217-JLM
OFFICE
1E218-JLM
RADIOLOGY
STAFF OFFICE
1E219-JLM
RADIOLOGY
STAFF OFFICE
C188-JLM
CORRIDOR 118
1E220-JLM
RADIOLOGY
STAFF OFFICE
1E223-JLM
COPY ROOM
1E224-JLM
ADMINISTRATIVE
OFFICER
1E225-JLM
CHIEF RADIOLOGY
1E122-JLM
MRI PATIENT
WAITING
1E129-JLM
MRI DRESSING RM
C138-JLM
CORRIDOR
1E100D-JLM
EXAM ROOM
1E100B-JLM
WAITING ROOM
1E100F-JLM
EXAM ROOM
1E100G-JLM
EXAM ROOM
1E100H-JLM
EXAM ROOM
1E100J-JLM
EXAM ROOM
1E100K-JLM
EXAM ROOM
1E100E-JLM
EXAM ROOM
1E100L-JLM
EXAM ROOM
1E101-JLM
EXAM ROOM
1E118-JLM
LOUNGE
1E119-JLM
ADMIN. OFFICER
1E120-JLM
OFFICE
1E115-JLM
ASSOC. CHIEF OF
STAFF AMBUL. CARE
1E116-JLM
RESTROOM
1E128-JLM
MRI PATIENT
RR
C191-JLM
CORRIDOR
1E127-JLM
MRI DRESSING
RM
1E126-JLM
MRI PATIENT
HOLDING
1E125-JLM
MRI EQUIPMENT
1E124-JLM
MRI RECPNT 2
1E130-JLM
STORAGE
1E
3-
JL
M
EX
AM
R
O O
M
1E114-JLM
EXAM ROOM
1E113-JLM
PROCEDURE ROOM
1E112-JLM
TELEPHONE
1E111-JLM
SIGNAL
1E100N-JLM
EXAM ROOM
1E100O-JLM
EXAM ROOM
1E100P-JLM
EXAM ROOM
1E100Q-JLM
EXAM ROOM
1E100R-JLM
CLINIC STAFF
1E117-JLM
BIO HAZ
1E100-JLM
EXAM
ROOM
C18-JLM
CORRIDOR
C110-JLM
CORRIDOR
1A103-JLM
OFFICE
1A104-JLM
WHEELCHAIR
COORD.
1A105-JLM
JANITOR
C116-JLM
CORRIDOR
1A107-JLM
MEN'S RR
1A102-JLM
STORAGE
C123-JLM
SERVICE
ELEVATOR
LOBBY
1B158-JLM
EXAM ROOM
1C141-JLM
AUDIOLOGIST
1D103-JLM
OFFICE
1D102-JLM
PHARMACY
SPRVSR
OFFICE
1D100-JLM
PHARMACY
1D101-JLM
STORAGE
1D100A-JLM
KITCHEN/
LOCKERS
1D106-JLM
ER 17
1D108-JLM
ER 16
1D110-JLM
ER 15
1D112-JLM
ER 14
1D114-JLM
ER 13
1D115-JLM
EQUIP.
STORAGE
1D104-JLM
NARCOTICS
VAULT
1D100C-JLM
PRESCRIPTION
RECEIVING
1D116-JLM
ELECTRIC
1D117-JLM
ADMISSION
1D122-JLM
WAITING AREA
1D124A-JLM
WOMEN'S RR
1D123A-JLM
MEN'S RR
1D128-JLM
SOILED
UTILITY
1D129-JLM
ER
PHYSICIAN
C168-JLM
CORRIDOR
1D125-JLM
ER CLEAN
SUPPLY
1D126-JLM
MED ROOM
1D132-JLM
LIFE SUPPORT
1D135-JLM
EQUIP. STORAGE
1D134-JLM
WOMEN'S RR
1D137-JLM
HC PAT TOIL
1D113-JLM
EXAM
1D111-JLM
TREATMENT
1D136-JLM
TREATMENT
1D138-JLM
ER LOUNGE
1D139-JLM
RESTROOM
1D141-JLM
TELEPHONE
C167-JLM
CORRIDOR
1D140A-JLM
OFFICE
1D147-JLM
NURSE STATION
1D146-JLM
EXPRESS
ADMISSIONS
C165-JLM
CORRIDOR
1D107-JLM
OFFICE
CHASE
1D105-JLM
EXAM ROOM
1D142-JLM
SIGNAL
1D140B-JLM
OFFICE
1D140C-JLM
OFFICE
1A116-JLM
SIGNAL
1A115-JLM
TELEPHONE
1A114-JLM
CANTEEN SERVICE
ADMINISTRATION
1A117-JLM
LOBBY95
1A118-JLM
CREDIT UNION
1A119-JLM
LOAN OFFICER
1A120-JLM
OFFICE
1A111-JLM
LINEN ROOM
1A110-JLM
TRASH
C122-JLM
CORRIDOR
1A112-JLM
CLEAN SUPPLY
PROCESSING & DISTRIB.
C124-JLM
CORRIDOR
1A113-JLM
ELECTRIC
1E146-JLM
DRESSING ROOM
1E147-JLM
RESTROOM
1E145-JLM
DRESSING ROOM
1E142-JLM
DRESSING ROOM
C178-JLM
CORRIDOR
1E104-JLM
WOMEN'S RR
1E103-JLM
JANITOR
1E106-JLM
VSO DAV
OFFICE
1E110-JLM
ELECTRIC
1E105-JLM
EYE CLINIC
RECEPTION
1E109-JLM
EYE CL.
OFFICE
1E121-JLM
OFFICE
1E136-JLM
MEN'S RR
1E137-JLM
STORAGE
1E107-JLM
VSO STATE
OFFICE
1E108-JLM
EYE CL. WAITING RM.
1E222-JLM
QA COORDI'TOR
C180-JLM
CORRIDOR
1E215-JLM
EQUIPMENT
STORAGE
1E204-JLM
FLOUROSCOPIC
ROOM 9
1E200-JLM
ULTRASOUND
WORKROOM
C
6-
JL
M C
O R
R
ID
O R
1E202-JLM
ULTRASOUND
ROOM 2
1E200A-JLM
CLEAN SUPPLY
1E154-JLM
CLEAN LINEN
1E201-JLM
ULTRASOUND
ROOM 1
1E147A-JLM
RADIOLOGY DRESSING AREA
1E148-JLM
RESTROOM
1E149-JLM
EQUIP. STORAGE
1E203-JLM
GENERAL PURPOSE
X-RAY ROOM 10
1A109-JLM
MEN'S RR
1A108-JLM
WOMEN'S RR
C121-JLM
STRETCHER
WAITING AREA
1E150-JLM
VESTIBULE
1E151-JLM
ULTRASOUND
ROOM 3
1E155-JLM
RESTROOM
1E
0-
JL
M
PT
. C O
N
SU
LT
1E
3-
JL
M W
O M
EN
'S
R R
1E193A-JLM
WOMEN'S
LOCKER
1E199-JLM
H.A.C.
1E193B-JLM
VESTIBULE
1E194B-JLM
VESTIBULE
1E194A-JLM
MEN'S LOCKER
1E194-JLM
MEN'S RR
1E191-JLM
XRAY 1
C125-JLM
RETAIL DISPLAY AREA
1E185-JLM
OFFICE
C184-JLM
CORRIDOR
1E180-JLM
RESTROOM
1E192-JLM
XRAY 2
1E195-JLM
XRAY 3
1E197-JLM
CT SCANNER
ROOM
1E196-JLM
XRAY 4
1E179-JLM
RESTROOM
1E177A-JLM
VESTIBULE
1E178-JLM
CLEAN SUPPLY
1E161-JLM
ELECTRIC
1E163-JLM
SIGNAL
1E166-JLM
RESTROOM
1E165-JLM
CT ULTRASOUND
WAITING
1E172-JLM
CT CONTROL
ROOM
1E198-JLM
CT SCANNER
ROOM
1E173-JLM
CT CONTROL ROOM65 1E
6-
JL
M
M
EC
H
AN
IC
AL
1E189-JLM
CLOSET
C120-JLM
CORRIDOR
1D184-JLM
EXAM
1D143-JLM
EQUIP.
STOR.
1D144-JLM
RAD.
RECEPT.
1D145-JLM
RAD. WAITING
1D182-JLM
WAITING
1D183-JLM
SECRETARY
C177-JLM
CORRIDOR
1E169-JLM
CT 3 SUITE 261
1E167-JLM
CT. PT. PREP.
1D171-JLM
READING ROOM
1D175-JLM
SIGNAL
1D174-JLM
TELEPHONE
1D165-JLM
CONFERENCE
1D167-JLM
PHYSICIAN
1D168-JLM
MSA
C
1-
JL
M C
O R
R
ID
O R
1D181-JLM
PATIENT RR
1D150-JLM
JANITOR
1D149-JLM
WAITING ROOM
1D148-JLM
OFFICE
1D152-JLM
ASSIST. CHIEF
HEALTH INFO.
SECT.
1D151-JLM
RELEASE OF
INFORMATION
1D153-JLM
CHIEF HEALTH
INFO. SECT.
1D180-JLM
RADIONUCLIDE
STORAGE
/HOT LAB
1D179-JLM
SPECT
LABORATORY
/EXAM
C173-JLM
CORRIDOR
1D162-JLM
STAFF RR
1D158-JLM
STRESS
LAB/EXAM
1D159-JLM
EXAM
1D161-JLM
PATIENT RR
1D160A-JLM
RADIOACTIVE
WSTE STOR.
1D160-JLM
LABORATORY
1D163-JLM
BREAK ROOM
1D164-JLM
RADIATION
1E301-JLM
MRI CONTROL
ROOM
1E304-JLM
STORAGE
1E305-JLM
MRI HAC
1E303-JLM
STORAGE
1E302-JLM
PREP. HOLDING
1E306-JLM
CONTROL
ROOM
1E310-JLM
MRI READING
AREA
C190-JLM
CORRIDOR257
C189-JLM
CORRIDOR
1E309-JLM
RESTROOM
1E300-JLM
MAGNET ROOM
1E308-JLM
MRI COMP./MECH.
C O
U N
TE
R
C O
U N
TE
R COUNTER
1E162-JLM
FAN ROOM
1B100A-JLM
MEN'S RR
1B144A-JLM
JANITOR
1B102A-JLM
WOMEN'S RR
1D120-JLM
WORK ROOM
TUBE
STATION
1D178-JLM
IMAGING
ELEV.
BREAKER
PANEL
S12-JLM
STAIR 2
PANEL
CONTROL
S14-JLM
STAIR 4
1B153A-JLM
VENDING
STOR.
1B152A-JLM
VENDING STORAGE
1B157A-JLM
VENDING AREA
1B156B-JLM
SIGNAL
1B155A-JLM
TELEPHONE
1B151A-JLM
MECH. ROOM
1B150A-JLM
JANITOR
1B
5A -J
LM
C
AN
TE
EN
S
R
VC
S
FO
O
D S
TO
R
1B161A-JLM
KITCHEN
1B154A-JLM
ELECTRIC
1B159A-JLM
FOOD SERVICE
1B166A-JLM
STORAGE
1B176-JLM
RETAIL SHOP
1B158A-JLM
CONFERENCE & DINING
C179-JLM
CORRIDOR
C185-JLM
CORRIDOR
C175-JLM
CORRIDOR
C174-JLM
CORRIDOR
S19-JLM
STAIR 9
C168A-JLM
VESTIBULE
C126-JLM
CORRIDOR
C
CC
C
C
C
C
S15-JLM
STAIR 5
92.5
S16-JLM
STAIR 6
S17-JLM
STAIR 7
S13-JLM
STAIR 3
S18-JLM
STAIR 8
S11-JLM
STAIR 1
ICE
MACHINE
WALK-IN
REFRIG.
WALK-IN
FREEZER
1D100B-JLM
PRESCRIPTION
INTAKE
1D129A-JLM
BATHROOM
1D159B-JLM
STORAGE
1D159A-JLM
EQUIP.
STORAGE
1E125A-JLM
STORAGE
1E148A-JLM
RADIOLOGY
NURSE'S STATION
1E221-JLM
RADIOLOGY
STAFF OFFICE
1B136A-JLM
STAFF
RESTROOM
1B140A-JLM
EXAM ROOM
C114A-JLM
VESTIBULE
C11-JLM
VESTIBULE
C12-JLM
VESTIBULE
C117-JLM
CORRIDOR
S1S5-JLM
STAIR S-5
C169-JLM
CORRIDOR
C170-JLM
CORRIDOR
C172-JLM
CORRIDOR
C178A-JLM
CORRIDOR
C130-JLM
CORRIDOR
C129-JLM
CORRIDOR
C128-JLM
CORRIDOR
C127-JLM
CORRIDOR
C127A-JLM
CORRIDOR
C131-JLM
CORRIDOR
C132-JLM
CORRIDOR
C133-JLM
CORRIDOR
C134-JLM
CORRIDOR
C135-JLM
CORRIDOR
C137-JLM
CORRIDOR
C136-JLM
CORRIDOR
C136A-JLM
CORRIDOR
C140-JLM
CORRIDOR
1D140D-JLM
OFFICE118
C167A-JLM
CORRIDOR
COUNTER
COUNTER
WORK
STATION
TRAP
FILTER/
COUNTER
STATION
WORK
WORK STATION
UPPER EXTREMITIES
FURRDOWNFURRDOWN
DESKTOP DESKTOP102
1B160B-JLM
EXAM
1B102-JLM
BREAK ROOM
1B103-JLM
ORTHO CAST
ROOM
1A121-JLM
STAFF OFFICE
1A123-JLM
LOUNGE
1A124-JLM
RECEPTION
1A125-JLM
STAFF OFFICE
1A126-JLM
STAFF OFFICE
1A127-JLM
STAFF OFFICE
1A128-JLM
STAFF OFFICE
C125A-JLM
CORRIDOR
C
5B -J
LM
C
O R
R
ID
O R
C125C-JLM
CORRIDOR
C125D-JLM
CORRIDOR
C180A
VSO WAITING.
1E100A-JLM
EXAM
ROOM
1E100C-JLM
STORAGE
C178B-JLM
CORRIDOR
1C142A-JLM
ACCOUSTICAL
ENCLOSURE
1C142B-JLM
ACCOUSTICAL
ENCLOSURE
1C142C-JLM
ACCOUSTICAL
ENCLOSURE
1C142D-JLM
ACCOUSTICAL
ENCLOSURE
1C142E-JLM
ACCOUSTICAL
ENCLOSURE
1C142F-JLM
ACCOUSTICAL
ENCLOSURE
PRNT
CABINETS
GAS MONITOR
G
AS
M O
N
IT
O R
G
AS
M O
N
IT
O R
WARMER
LO
C
KE
R
S
LO
C
KE
R
S
GAS MONITOR
G
AS
M O
N
IT
O R
GAS MONITOR
CONTROLS
LIGHT
COUNTER
COUNTER
CONTROLS
LIGHT
G
AS
M O
N
IT
O R
GAS MONITOR
FD
FD
GAS MONITORGAS MONITOR
PANEL
1QL5
PANEL
1QH3
PANEL
MAIN
1L13
PANEL
1H10
PANEL
1CL2
XFRMR
FD
TROLLEY
HOIST
ABOVE
HOIST
TRACK
ABOVE
GAS MONITOR
SLIDING WINDOW
SL
ID
IN
G
W
IN
D O
W
SLIDING WINDOW
CHASE
ROLL-UP
SCREEN
ABOVE
C O
U N
TE
R
C O
U N
TE
R
1CL2
PANEL
DISC.
CONTROLS
SIEMENS
PANEL
1QL2
PANEL
1QH2
1PL4
PANEL
PANEL
1H5
1L5
PANEL
CAB.
CONTROL
C O
U N
TE
R
1D131A-JLM
ELEC ROOM
1D127B-JLM
ER 2 117
1D127C-JLM
ER 3
1D127D-JLM
ER 4
1D127E-JLM
ER 5
1D127F-JLM
ER 6
1D127G-JLM
ER 7
1D130-JLM
STAFF LOCKER
1D127A-JLM
ER 1
1D118A-JLM
TRIAGE A
1D118B-JLM
TRIAGE B
1D127H-JLM
ER 8
1D127J-JLM
ER 9
1D127K-JLM
ER 10
BRICK LEDGE
8'-0"x6'-5" OVERHEAD DOOR
8'- 0"x
6'- 3"
OVERHEAD D
OOR
1D127-JLM
NURSE'S STATION
CANOPY
SUPPORT
SUPPORT
CANOPY
POWERS
CONTROLS
XFRMR
1L13/
1QL5
1D120A-JLM
AOD/PATIENT
EXPEDITOR
C165A-JLM
NURSE'S STATION
C166-JLM
CORRIDOR
1D133-JLM
DECON
SHOWERS
BUST
C O
FF
EE
S H
O P
TRASH CONTAINER
UNDER COUNTER
1A134-JLM
CANTEEN
STORAGE
1A135-JLM
COFFEE SHOP
1B165B-JLM
CANTEEN SVC
OFFICE
FO
O
D S
ER
VI
C E
C O
U N
TE
R
FO
O
D S
ER
VI
C E
SH
EL
VE
S
DOOR
No. 1
DOOR
No. 2
No. 3
DOOR
No. 22
DOOR
No. 24
DOOR
SHAFT
C-3
SW-1
SHAFT
C-1
SHAFT
1E226-JLM
RADIOLOGY
SECRETARY
C188A-JLM
CORRIDOR130
1E133A-JLM
RADIOLOGY
STAFF
1E133B-JLM
RADIOLOGY
STAFF
C188B-JLM
CORRIDOR
C188C-JLM
CORRIDOR
C
AB
IN
ET
TV
RF Window
C
AB
IN
ET
S
RAMP UP
COUNTER
1D146A-JLM
RECPT OFFICE
1D146B-JLM
EXAM RM
1D146C-JLM
OFFICE/EXAM
1D146D-JLM
HC TOIL
1D146E-JLM
PHYSN OFFICE
1D146F-JLM
CLERICAL
Cased Opening
PASS-THRU
WINDOW
GAS MONITORGAS MONITOR GAS MONITOR
G
AS M
O N
ITO
R
G
AS M
O N
ITO
R
G
AS M
O N
ITO
R
1D147B-JLM
CLEAN
LINEN
1D147C-JLM
ER 23
1D147D-JLM
ER 22
1D147E-JLM
ER 21 76
1D147F-JLM
MED RM
1D147G-JLM
ER 20
1D147H-JLM
ER 19
1D147J-JLM
SOIL UTIL
1D147K-JLM
ER 18
OPENING
CASED
JOINT
EXPANSION
BUS
POWER
EQUIP.
ELEV.
CAB.
CONTROL
DISCS.
CO
CO
SHOWER
TRANS-
FORMER
FORMER
TRANS-
SEC. 1
PANEL
1FCL11FCL1
PANEL
SEC. 2
1FCL2
PANEL
SEC. 1SEC. 2
PANEL
1FCL2
PANEL
1FNH1
1FEQL1
PANEL
COUNTER
SHOWER
CO
COUNTER
FLOOR
EDGE OF
DN
STATION
TUBE
VALVES
WATER
CO
C O
U N
TE
R
COUNTER
CO
CO
COUNTER
COUNTER
FIRE
ROOF
ACCESS
LADDER
MEDGAS
PANEL
TYP.
MEDGAS
PANEL
TYP.
CONDUITS
IN FLOOR
PIPE
PIPE
GAS
LO
C
KE
R
S
LOCKERS
LO
C
KE
R
S
ELEVATOR
1F119-JLM
ICU
1F120-JLM
ICU
1F121-JLM
ICU
1F122-JLM
ICU
1F123-JLM
ICU
1F124-JLM
ICU
1F125-JLM
ICU
1F126-JLM
ICU
1F127-JLM
ICU
1F128-JLM
ICU
1F129-JLM
ICU
1F130-JLM
SHOWER
1F131-JLM
ANTE
1F132-JLM
ISOLATION ICU
1F133-JLM
EXAM82
1F134-JLM
CONSULT
1F104-JLM
COMM
ROOM
1F103-JLM
EQUIPMENT
STORAGE
1F101-JLM
ELEVATOR
EQUIPMENT
1F100-JLM
EQUIP.
STORAGE
C192-JLM
CORRIDOR
C193-JLM
CORRIDOR
1F102-JLM
WAITING
1F105-JLM
VESTIBULE
1F107-JLM
TOILET
1F106-JLM
SHOWER
1F108-JLM
RESPIRATORY
1F109-JLM
JANITOR
1F136-JLM
RESIDENT
DIRECTOR
1F135-JLM
PHYSICIAN
OFFICE
1F150-JLM
SHOWER
1F149-JLM
HALL
1F148-JLM
ON-CALL
1F147-JLM
ON-CALL
1F146-JLM
SOILED
UTILITY
1F145-JLM
CLEAN
UTILITY
1F152-JLM
NURSE'S
STATION
C194-JLM
CORRIDOR
1F157-JLM
MED ROOM
1F158-JLM
NOURISHMENT
1F156-JLM
WORKROOM/
HOUSE STAFF
1F155-JLM
CONFERENCE
1F151-JLM
HALL
1F144A-JLM
CLEAN LINEN
1F144-JLM
CONFERENCE
1F143-JLM
TOILET
1F142-JLM
TOILET
1F139-JLM
CLEAN
SUPPLY
1F138-JLM
ELEC ROOM
1E133F-170
RADIOLOGY
STAFF
1E133G-170
RADIOLOGY
STAFF
1E133H-170
RADIOLOGY STAFF
S110-JLM
STAIR 10
1B176A-JLM
RETAIL REFRIG.
1E148B-JLM
PANOREX EXAM
SPECIAL PROCEDURE ROOM
1E184A-JLM
VESTIBULE
Sliding Glass Door
C O
U N
TER
C
O U
N
TER
C O
U N
TER
CAPPNCAPMCCAPQT
C119-JLM
NORTH ATRIUM
85 1A
6-
JL
M
SC
H
ED
U
LE
D
AD
M
IS
SI
O
N S
CAPPNCAPMCCAPQTCAPDH
CAPTG
CAPPNCAPMCCAPQTCAPDH
CAPTG
CAPPNCAPMCCAPQTCAPDH
CAPTG
CAPDH
CAPTG
CAPPNCAPMCCAPQTCAPDH
C
APTG
88 1A
7-
JL
M
PR
O G
R
AM
AS
SI
ST
CAPDH
CAPQT
CAPPNCAPMC
CAPQT
CAPQTCAPDH
CAPTG
CAPPNCAPMCCAPQT
CAPTG
1A141-JLM
RAD. PT.
HOLDING
1A140-JLM
RAD. DR.
#4
RAD. PT.
#2
RAD. PT.
CAPPNCAPMCCAPDH CAPTG
CAPPNCAPMCCAPQTCAPDH
CAPTG
CAPPNCAPMCCAPDH
C
AP
TG
1A139-JLM
RAD. WAITING
#1
RAD. PT.
#3
RAD. PT.
1D183A-JLM
WORKSTATION
SHELVING
MED ROOM
1E102-JLM
OFFICE
EQUIPMENT STORAGE
ISOLATION ICU
1F-111
ICU
1F-114
ICU
1F-115
ICU
1F-116
OFFICE
1F-110
SWHR
1F-112
ANTE
1F-113
NURSE STATION
1F-141
CORRIDOR
C1-94
1F-117
1F-118
SOILED
UTIL
1F-137
NOUR
1F-154
CLEAN
UTIL
1F-140
MED
1F-153
ICU
ICU
C O
U N
TE
R
COUNTER
COUNTER
CONDUITS
IN FLOOR
C114B-JLM
VESTIBULE
C170A-JLM
CORRIDOR
C168B-JLM
VESTIBULE
S19A-JLM
STAIR 9
1B159B-JLM
SERVING LINE
C110A-JLM
STORAGE
1D133A-JLM
DECON
SHOWERS
1D133B-JLM
EMERG SHWR
1D133C-JLM
EMERG SHWR
1D133D-JLM
EMERG SHWR
1D133E-JLM
EMERG SHWR
1R1-JLM
1R1A-JLM
C180A-JLM
CORRIDOR
AP-04
F.E.
C116
CORRIDOR
WP-2, WP-3
WP-2, WP-3
C151
CORRIDOR
1C165
DERM.
PHOTOTHERAPY
1C163
DERM.TLT
1C164
DERM.
PROCEDURE
C156
CORRIDOR
C154
CORRIDOR
1C157
MED GAS
STG.1C161
DERM.
HAC
1C174
DERM.
SLD UTIL.
1C169
STOR.
1C166
DERM.
EXAM
1C170
1C180
NURSE
1C178
HEAD
NURSE
1D121B
ARMORY
1D
1E C
O R
R
ID
O R
1D121F
INTERVIEW
OFFICE
1D121A
EVIDENCE
1D121C
HOLDING
CELL
1C176
DERM.
CLN UTIL.
C113
CORRIDOR N.I.S
1C182
SHARED
WAITING
C150
CORRIDOR
C112
LOBBY
1C162
DERM.
EXAM
1C159
DERM.
EXAM DERM.
EXAM
1C160
DERM.
EXAM
1C172
DERM.
LAB
1C167
STAFF
LOUNGE/
LOCKER
ROOM
1C168
DERM.
EXAM
C155
CORRIDOR
1D121D
DISPATCH
1D121
SECURITY
DN
UP
EKG
WAITING
1C107
EKG
PROCEDURE
ROOM 2
1C107C
HAC
1C121SLD. UTIL.
1C125
ENT EXAM
& TRTMNT
1C129
STF TLT
1C190
CORRIDOR
C144A
GMA
1C133
AGENT
CASHIER
1C104
ENT EXAM
& TRTMNT
1C189
ENT EXAM
& TRTMNT
1C186
NURSE
PROC/APN.
OFFICE
1C181
ENT
PROCEDURE
1C185
OFFICE
1C183
CBO
OFFICE
1C105
CORRIDOR
C12
PUBLIC
ELEVATOR
LOBBY
C19
1C104B STF. TLT
1C107D
EKG
PROCEDURE
ROOM 1
1C107A
ENT EXAM
& TRTMNT
1C124
STOR.
1C126
STF TLT
1C104A
ENT EXAM
& TRTMNT
1C128
NURSE
C143A
CORRIDOR
C139
VS
SUPPLY
RM
1C116
CHECK-IN
1C132
ENT
PROCEDURE
1C187
ENT EXAM
& TRTMNT
1C123
VS OFFICE
1C119
VS OFFICE
1C117
VOL. SERV
SLEEP RM
1C118
VS
LOUNGE
1C115
V. Services Hallway C177
CLN. UTIL.
1C127
1C131E
1C131D 1C131
1C131B 1C131C1C131F
PERC
OFFICE
1C130C
PATIENT
ED.
RESOURCE
CENTER
1C130B
PERC
OFFICE
1C130A
CORRIDOR
C143
1C188
COFFEE
SHOP
1A135
1C131
1C130C
CORRIDOR
C136
CORRIDOR
C137
1B173A
CORRIDOR
C15
W P-
2, W
P-
CORRIDOR
1C184
1C155
1C216
1C215-JLM
STORAGE
C162-JLM
CORRIDOR
1C214 1C203
C159-JLM
CORRIDOR
1C200
1C202 1C195-JLM
WOMEN'S RR
1C194-JLM
MEN'S RR
1C199-JLM
RECEPTIONIST
1C201
1C212
1C209-JLM
EMS STORAGE
C160-JLM
CORRIDOR
Lisa 1C206
1C208Patient Rep Lee McFadden
1C192-JLM
ESCORT
1C152-JLM
CLERICAL
1C153-JLM
NUTRITION
CLINIC
1C151D-JLM
SOCIAL
WORKER
1C151C-JLM
INVENTORY
1C151A-JLM
SOCIAL
WORKER
1C150-JLM
SUPERVISOR
1C232-JLM
ELIGIBILITY
CTR.
1C151B-JLM
PHARMACIST 303
1C149-JLM
ADMISSIONS
1C211
1C213
1C151G-JLM
SOCIAL
WORKER
1C151F-JLM
SOCIAL
WORKER
1C151E-JLM
PHARMACIST
1C198-JLM
JANITOR
1C228-JLM
WAITING
1K196-JLM
1C204
1C221
1C205
1C217
1C218
1C219-JLM
1C220-JLM
1C222-JLM
1C223-JLM
C163-JLM
CORRIDOR
1C224-JLM 92
1C225-JLM
1C227-JLM
RECEPTIONIST
1C229-JLM
1C230-JLM
SECURITY
OFFICE
1C231-JLM
C151-JLM
CORRIDOR
C161-JLM
CORRIDOR
C153-JLM
CORRIDOR
Red Coat Storage
1E135D
C176-JLM
CORRIDOR
1E177F
1E177E
1E177D
1E177A
1E177H
1Z109
1Z106
1Z108
1E177G
1D170 1E184
1D167
1Z101B
1E182
1E177B
1Z103
1E177C
1E1781E179
1E157A
1E143
1E2121E213
1E134C
1E133D
1E134E
1E134D
1E169
1E135A
1E160
1E135E
1E135B 1E135C
1E134A
1E134B
1E157C
1E158A
CONFERENCE ROOM
C187-JLM
CORRIDOR
1E134A-JLM
VESTIBULE
1E141A-JLM
VESTIBULE
1E144-JLM
RESTROOM
1E144A-JLM
VESTIBULE
EX
IT
C
1D170-JLM
RADIATION
SAFETY
OFFICE
B
A
A
A
AMBULATORY HEALTH
CARE OCCUPANCY
FULLY SPRINKLERED
STANDARD RESPONSE
AMBULATORY HEALTH CARE
OCCUPANCY
FULLY SPRINKLERED
STANDARD RESPONSE
HEALTH CARE OCCUPANCY
FULLY SPRINKLERED
STANDARD RESPONSE
EX
EX
EX
EX
HEALTH CARE OCCUPANCY
FULLY SPRINKLERED
STANDARD RESPONSE
SZ
1E-2
SZ
1E-1
SZ
1D-2
SZ
1D-1
SZ
1C-1
SZ
1C-2
K
D
OFFICE
WAITING
1C143
OFFICE/EXAM
SLIDING
DOOR
1C129
ROOF
SZ
1A-1 SZ
1A-2
C
C
1A122-JLM
SZ
1E-2
SZ
1B-2
SZ
1B-2
SZ
1B-1
SZ
1E-1
SZ
1D-1
SZ
1A-3
1C158-JLM
ELECTRICAL
1C159-JLM
IT
SAFETY
OFFICE
LOUNGE / QC SCHEDULER
QUALITYGEN RAD SUPER MANAGEMENT
CONF
MAMMO
ULTRASOUND
RECEPTION
TOILET
READING
WAITING
TOILET
STEREO BIOPSY MAMMO
CORR
DRESS DRESS
DRESS
ULTRASOUND
TRANSFRMRS
1D176-JLM
ELECTRIC
1D177-JLM
EXAM
UP TO
OVERHEAD
WALKWAY
1D166-JLM
NURSE
MANAGER
1D131-JLM
CLEAN LINEN
1E205-JLM
FLOUROSCOPIC
ROOM 8
1E206-JLM
BARIUM PREP.
1E207-JLM
FLOUROSCOPIC
ROOM 7
FLOUROSCOPIC
READNG
TECH WORK
C
1-
JL
M C
O R
R
ID
O R
1E133E-JLM
RADIOLOGY
STAFF
1E307-JLM
MRI SCAN ROOM
1E181-JLM
INSTRUMENT
STORAGE
1E164-JLM
TELEPHONE
C183-JLM
CORRIDOR
1E168-JLM
CT 3 CONTROL
ROOM
1B149-JLM
RESTROOM
1A106-JLM
WOMEN'S RR
1E177-JLM
SPECIAL
PROCEDURE
ROOM
1B149A-JLM
CANTEEN
STOR.
1E186-JLM
RESTROOM
1E133C-JLM
RADIOLOGY
STAFF
UNDER CONSTRUCTION
SITE NAME/ADDRESS
REVISIONS: NUMBER DATE
ENGINEERS
Approved: Project Director Location
Issue Date
LITTLE ROCK, ARKANSAS
07/12/2023
Drawing Title Project Title
Building Number
Drawing Number
Dwg. of 13
Project Number
139 Old Creek Road Palos Park, IL 60464 and 12200 Bunya Lane Ruther Glen, VA 22546 Tel: 703-477-5928 Email: dale.wheeler@systechfire.com Checked By
DRW / JSW
Drawn By
TCG
Dept. of Veterans Affairs Medical Center 4300 W. 7th Street Little Rock, Arkansas 72205
J.L. McCLELLAN VAMC
STATEMENT OF CONDITIONS
DOCUMENTATION
PARTITION LEGEND
2 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE ZONE BARRIER
SMOKE ZONE BARRIER
1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
SYMBOLS LIST
HORIZONTAL EXIT PASSAGEWAY
EXIT
EXIT PASSAGEWAY
LINEN CHUTE
TRASH CHUTE
EP
TC
EX
HE
AREA OPEN TO CORRIDOR WITH SMOKE DETECTION
AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED
SUITE DESIGNATION
1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
SPRINKLER / FIRE SMOKE ZONE
NON-RATED…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .