17-PFC024_James_Hall_Str_Repairs_Drawings_43.pdf
PDF 351 KB Posted
- Solicitation number
- HSCG83-17-B-PFC024
About this file
USCG Reference Drawings T-6883-MD
View the file
Other files
Show 40 more
Latest 50 of 74 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEMOLITION KEYED NOTES
DEMOLITION PLAN
KEY PLAN
GRAPHIC SCALE
PLAN
/2 4/
AutoCAD SHX Text
1. EXISTING SANITARY LINE THAT DROPS FROM FLOORS EXISTING SANITARY LINE THAT DROPS FROM FLOORS ABOVE IS TO REMAIN OPERATIONAL DURING THE PROJECT EXCEPT FOR THE SHORT DURATION WHEN THE BELOW-FLOOR SECTION OF THIS SS LINE IS BEING REPLACED WITH NEW. DURING SLAB DEMOLITION, TEMPORARILY SUPPORT LINE FROM BELOW AND PROTECT LINE FROM DAMAGE. 2. REMOVE ALL EXISTING PLUMBING FIXTURES, FIXTURE REMOVE ALL EXISTING PLUMBING FIXTURES, FIXTURE CARRIERS, FAUCETS, FLUSH VALVES, SHOWER HEADS, FLOOR DRAINS, AND SHOWER DRAINS. REMOVE ASSOCIATED VENT PIPING TO ABOVE CEILING. CAP EACH FOR RECONNECTION. 3. EXISTING 4" ROOF DRAIN LINE THAT DROPS FROM EXISTING 4" ROOF DRAIN LINE THAT DROPS FROM ABOVE AT THIS LOCATION IS TO REMAIN OPERATIONAL DURING THE PROJECT. DURING SLAB DEMOLITION, TEMPORARILY SUPPORT LINE FROM BELOW AND PROTECT LINE FROM DAMAGE. 4. REMOVE, CLEAN, AND STORE FOR REINSTALLATION REMOVE, CLEAN, AND STORE FOR REINSTALLATION EXISTING STAINLESS STEEL COUNTER AND LAVATORIES. FAUCETS WILL BE REPLACED WITH NEW. 5. REMOVE, CLEAN, AND STORE FOR REINSTALLATION REMOVE, CLEAN, AND STORE FOR REINSTALLATION EXISTING STAINLESS STEEL WATER TROUGH AND TAP WATER DISPENSERS (5X).
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 3/16" = 1'-0"
AutoCAD SHX Text
2"SS
AutoCAD SHX Text
2"SS
AutoCAD SHX Text
4"SS
AutoCAD SHX Text
4"SS DOWN FROM ABOVE
AutoCAD SHX Text
4"SS
AutoCAD SHX Text
4"SS
AutoCAD SHX Text
5"SS
AutoCAD SHX Text
6"SS
AutoCAD SHX Text
4"SS DOWN FROM ABOVE
AutoCAD SHX Text
2"SS
AutoCAD SHX Text
5"SS
AutoCAD SHX Text
4"SS DOWN FROM ABOVE
AutoCAD SHX Text
3"SS DOWN FROM ABOVE
AutoCAD SHX Text
4"SS OVERHEAD
AutoCAD SHX Text
4"SS
AutoCAD SHX Text
4"SS
AutoCAD SHX Text
4"SS
AutoCAD SHX Text
5"SS
AutoCAD SHX Text
5"SS
AutoCAD SHX Text
3"SS
AutoCAD SHX Text
4"SS
AutoCAD SHX Text
4"SS
AutoCAD SHX Text
4"SS
AutoCAD SHX Text
4"SS
AutoCAD SHX Text
4"SS
AutoCAD SHX Text
4"SS
AutoCAD SHX Text
2"SS
AutoCAD SHX Text
2"SS
AutoCAD SHX Text
2"SS
AutoCAD SHX Text
2"SS
AutoCAD SHX Text
5"SS
AutoCAD SHX Text
FD
AutoCAD SHX Text
FD
AutoCAD SHX Text
SD
AutoCAD SHX Text
SD
AutoCAD SHX Text
SD
AutoCAD SHX Text
SD
AutoCAD SHX Text
SD
AutoCAD SHX Text
WC'S
AutoCAD SHX Text
LAV'S
AutoCAD SHX Text
LAV'S
AutoCAD SHX Text
UR'S
AutoCAD SHX Text
SERV SINK
AutoCAD SHX Text
LAV
AutoCAD SHX Text
WC
AutoCAD SHX Text
LAV
AutoCAD SHX Text
LAV
AutoCAD SHX Text
EWC
AutoCAD SHX Text
UR
AutoCAD SHX Text
WC
AutoCAD SHX Text
WC
AutoCAD SHX Text
WC
AutoCAD SHX Text
WC
AutoCAD SHX Text
UR
AutoCAD SHX Text
WC'S
AutoCAD SHX Text
LAV'S
AutoCAD SHX Text
LAV'S
AutoCAD SHX Text
UR'S
AutoCAD SHX Text
SERV SINK
AutoCAD SHX Text
2"V UP TO ABOVE
AutoCAD SHX Text
3"V UP TO ABOVE
AutoCAD SHX Text
4"SS DOWN FROM ABOVE
AutoCAD SHX Text
2"V UP TO ABOVE
AutoCAD SHX Text
4"SS DOWN FROM ABOVE
AutoCAD SHX Text
3"V UP TO ABOVE
AutoCAD SHX Text
3"SS DOWN FROM ABOVE
AutoCAD SHX Text
3"V UP TO ABOVE
AutoCAD SHX Text
4"SS DOWN FROM ABOVE
AutoCAD SHX Text
2"V UP TO ABOVE
AutoCAD SHX Text
2"V UP TO ABOVE
AutoCAD SHX Text
4"SS DOWN FROM ABOVE
AutoCAD SHX Text
4"SS DOWN FROM ABOVE
AutoCAD SHX Text
4"V UP FROM BELOW TO ABOVE
AutoCAD SHX Text
DF
AutoCAD SHX Text
DF
AutoCAD SHX Text
EWC
AutoCAD SHX Text
BFS
AutoCAD SHX Text
COND DRAIN DOWN FROM ABOVE
AutoCAD SHX Text
FCU COND DRAIN ACROSS FLOOR
AutoCAD SHX Text
4"SS DROPS AT WALL
AutoCAD SHX Text
SS LINES FROM DF'S ARE ABOVE FLOOR
AutoCAD SHX Text FROM THIS POINT, ALL UPSTREAM SS PIPE THAT IS BELOW THE FIRST FLOOR SLAB IS BEING REPLACED UNDER THIS PROJECT. REPLACEMENT WILL REQUIRE SEQUENCING AND COORDINATION WITH USER TO ISOLATE AND MINIMIZE OPERATIONAL DOWNTIME OF UPPER FLOOR PLUMBING FACILITIES.
AutoCAD SHX Text
EXISTING 6" SS TO REMAIN
AutoCAD SHX Text
AutoCAD SHX Text
MECH RM
AutoCAD SHX Text
AutoCAD SHX Text
MECHANICAL ROOM
AutoCAD SHX Text
AutoCAD SHX Text
HALL
AutoCAD SHX Text
AutoCAD SHX Text
HALL
AutoCAD SHX Text
AutoCAD SHX Text
HALL
AutoCAD SHX Text
AutoCAD SHX Text
HALL
AutoCAD SHX Text
AutoCAD SHX Text
MECHANICAL ROOM
AutoCAD SHX Text
EXISTING PIT
AutoCAD SHX Text
CAPE MAY
AutoCAD SHX Text
TRAINING CENTER
AutoCAD SHX Text
U. S. COAST GUARD
AutoCAD SHX Text
USCG, TRACEN CAPE MAY
AutoCAD SHX Text
1 MUNRO AVE.
AutoCAD SHX Text
CAPE MAY, NJ 08204-5092
AutoCAD SHX Text
CMS-1476
AutoCAD SHX Text
JAB
AutoCAD SHX Text
WDP
AutoCAD SHX Text
1:1 PS
AutoCAD SHX Text
JAB
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text
WDP
AutoCAD SHX Text
BUILDING 258
AutoCAD SHX Text
TRACEN
AutoCAD SHX Text
DEMOLITION PLAN - WASTE
AutoCAD SHX Text
PLUMBING
AutoCAD SHX Text
NEW JERSEY
AutoCAD SHX Text
STRUCTURAL REPAIRS TO JAMES HALL
AutoCAD SHX Text
CAPE MAY
AutoCAD SHX Text 4376510
AutoCAD SHX Text
T-6883-MD
AutoCAD SHX Text
PD101
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text R
AutoCAD SHX Text D
AutoCAD SHX Text G
AutoCAD SHX Text U
AutoCAD SHX Text A
AutoCAD SHX Text O
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text 16'
AutoCAD SHX Text
SCALE: 3/16"= 1'-0"
AutoCAD SHX Text 2'
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text
CONSULTANTS
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text
REVIEWED BY:
AutoCAD SHX Text
PROJECT ENG.
AutoCAD SHX Text
APPROVING OFFICER
AutoCAD SHX Text
PROJECT NUMBER
AutoCAD SHX Text
DISCIPLINE/SHT NO
AutoCAD SHX Text
REVIEWED BY:
AutoCAD SHX Text
BRANCH CHIEF
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
EDITED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
A/E PROJECT NO:
AutoCAD SHX Text
CAD FILE NAME:
AutoCAD SHX Text
SHEET TITLE
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
PLOT SCALE:
AutoCAD SHX Text
MARK
AutoCAD SHX Text
ISSUE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REGISTERED
AutoCAD SHX Text
ENGINEER
AutoCAD SHX Text
PROFESSIONAL
AutoCAD SHX Text
ARKANSAS
AutoCAD SHX Text E
AutoCAD SHX Text
NO. 5838
AutoCAD SHX Text W
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text L
AutoCAD SHX Text D.
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text Y
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text M
RJCaruso SAM Proj No for Const
RJCaruso CMS Stamp
File details come from the government source that posted it. Updated .