17-PFC024_James_Hall_Str_Repairs_Drawings_37.pdf
PDF 330 KB Posted
- Solicitation number
- HSCG83-17-B-PFC024
About this file
USCG Reference Drawing T-6877-MD
View the file
Other files
Show 40 more
Latest 50 of 74 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEMOLITION PLAN
KEY PLAN
GRAPHIC SCALE
PLAN
DEMOLITION KEYED NOTES
/2 4/
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 3/16" = 1'-0"
AutoCAD SHX Text
1. EXISTING FCU TO BE REPLACED WITH NEW FTR IN EXISTING FCU TO BE REPLACED WITH NEW FTR IN THIS PROJECT. PRIOR TO DEMOLITION OF FIRST FLOOR SLAB AND WALLS, REMOVE EXISTING FCU. REMOVE PIPING TO ABOVE CEILING AND INSTALL NEW SHUTOFF VALVES ON EXISTING LINES ABOVE CEILING. TEMPORARILY CAP VALVES TO PREVENT DEBRIS ENTRY. 2. EXISTING FTR TO BE REPLACED IN THIS PROJECT. EXISTING FTR TO BE REPLACED IN THIS PROJECT. PRIOR TO DEMOLITION OF FIRST FLOOR SLAB AND WALLS, REMOVE EXISTING FTR. REMOVE PIPING TO ABOVE CEILING AND INSTALL NEW SHUTOFF VALVES ON EXISTING LINES ABOVE CEILING. TEMPORARILY CAP VALVES TO PREVENT DEBRIS ENTRY. 3. AFTER NEW HHW PUMPS ARE OPERATIONAL, REMOVE AFTER NEW HHW PUMPS ARE OPERATIONAL, REMOVE EXISTING 3" WATER LINES THAT DROP TO HEADER LOCATED BELOW PUMPS. REMOVE HEADER. 4. EXISTING DX FAN COIL TO BE TEMPORARILY EXISTING DX FAN COIL TO BE TEMPORARILY REMOVED AND REINSTALLED LATER IN PROJECT AFTER NEW FLOOR AND WALLS ARE IN PLACE. REMOVE ASSOCIATED REFRIGERANT PIPING AND CONDENSATE PIPING AND CAP, PROTECTING PIPE AS NEEDED FOR DEMOLITION OF OTHER TRADES. 5. REMOVE, CLEAN, REPAINT AND STORE EXISTING REMOVE, CLEAN, REPAINT AND STORE EXISTING EXHAUST INTAKE LOUVER. REMOVE DUCTWORK BACK TO ALLOW FOR WALL REMOVAL. INSTALL FILTER MEDIA OVER OPEN DUCT INTAKES DURING DEMOLITION TO MINIMIZE INTAKE OF PARTICULATES. 6. REMOVE, CLEAN, REPAINT AND STORE EXISTING REMOVE, CLEAN, REPAINT AND STORE EXISTING EXHAUST INTAKE GRILLE. INSTALL FILTER MEDIA OVER OPEN DUCT INTAKES DURING DEMOLITION TO MINIMIZE INTAKE OF PARTICULATES. 7. NOTE THAT CUTTING IN OF NEW ISOLATION VALVES NOTE THAT CUTTING IN OF NEW ISOLATION VALVES AND INSTALLATION OF NEW HHW PUMPS AND PIPING SHOULD ALL BE ACCOMPLISHED IN THE FIRST PHASE SO AS TO ALLOW FOR REMOVAL OF THE EXISTING PUMPS PRIOR TO REMOVAL OF THE SLAB. 8. EXISTING V/D UNIT TO BE REMOVED, STORED AND EXISTING V/D UNIT TO BE REMOVED, STORED AND REINSTALLED UNDER THIS PROJECT. DURING DEMOLITION OF FIRST FLOOR SLAB AND WALLS, REMOVE EXISTING V/D. DUCTWORK TO REMAIN EXCEPT AS REQUIRED TO FACILITATE REMOVAL AND REINSTALLATION OF WALLS AND FLOOR. REMOVE GLYCOL CHILLED WATER PIPING AND HEATING HOT WATER PIPING TO ABOVE CEILING. PERMANENTLY CAP GLYCOL CHILLED WATER PIPES. INSTALL NEW SHUTOFF VALVES ABOVE CEILING ON HEATING HOT WATER PIPING. TEMPORARILY CAP VALVES AND COIL CONNECTIONS TO PREVENT DEBRIS ENTRY UNTIL RECONNECTION.
AutoCAD SHX Text
EXISTING DT PUMPS TO BE REMOVED ONCE NEW PUMPS ARE OPERATIONAL
AutoCAD SHX Text
EXISTING SHOT FEEDER TO BE RELOCATED
AutoCAD SHX Text
PANEL TO BE RELOCATED. SEE M-401
AutoCAD SHX Text PANEL TO BE REINSTALLED IN THIS LOCATION AFTER NEW WALLS ARE CONSTRUCTED. SEE M-401
AutoCAD SHX Text EXISTING OVERHEAD DOMESTIC WATER CIRC PUMP AND SYSTEM PIPING IN THIS AREA TO REMAIN AS IS
AutoCAD SHX Text
OVERHEAD VALVING IN THIS AREA IS TO REMAIN
AutoCAD SHX Text
EQUIPMENT PAD (FORMERLY CH-2)
AutoCAD SHX Text
EQUIPMENT PAD (FORMERLY CH-1)
AutoCAD SHX Text
AutoCAD SHX Text
MECHANICAL ROOM
AutoCAD SHX Text
AutoCAD SHX Text
MECHANICAL ROOM
AutoCAD SHX Text
AutoCAD SHX Text
MECH. ROOM
AutoCAD SHX Text
AutoCAD SHX Text
HALL
AutoCAD SHX Text
AutoCAD SHX Text
HALL
AutoCAD SHX Text
AutoCAD SHX Text
HALL
AutoCAD SHX Text
AutoCAD SHX Text
HALL
AutoCAD SHX Text
EXISTING PIT
AutoCAD SHX Text REMOVE GLYCOL CHILLED WATER PUMPS, SHOT FEEDER, GLYCOL CHILLED WATER PIPING, AND GLYCOL EXPANSION TANKS IN THIS AREA OF MECH RM 112. THESE ITEMS WERE ABANDONED IN PLACE UNDER A SEPARATE CONTRACT
AutoCAD SHX Text
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text 16'
AutoCAD SHX Text
SCALE: 3/16"= 1'-0"
AutoCAD SHX Text 2'
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
CAPE MAY
AutoCAD SHX Text
TRAINING CENTER
AutoCAD SHX Text
U. S. COAST GUARD
AutoCAD SHX Text
USCG, TRACEN CAPE MAY
AutoCAD SHX Text
1 MUNRO AVE.
AutoCAD SHX Text
CAPE MAY, NJ 08204-5092
AutoCAD SHX Text
CMS-1476
AutoCAD SHX Text
JAB
AutoCAD SHX Text
WDP
AutoCAD SHX Text
1:1 PS
AutoCAD SHX Text
JAB
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text
WDP
AutoCAD SHX Text
BUILDING 258
AutoCAD SHX Text
TRACEN
AutoCAD SHX Text
DEMOLITION PLAN
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
NEW JERSEY
AutoCAD SHX Text
STRUCTURAL REPAIRS TO JAMES HALL
AutoCAD SHX Text
CAPE MAY
AutoCAD SHX Text 4376510
AutoCAD SHX Text
T-6877-MD
AutoCAD SHX Text
MD101
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text
CONSULTANTS
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text
REVIEWED BY:
AutoCAD SHX Text
PROJECT ENG.
AutoCAD SHX Text
APPROVING OFFICER
AutoCAD SHX Text
PROJECT NUMBER
AutoCAD SHX Text
DISCIPLINE/SHT NO
AutoCAD SHX Text
REVIEWED BY:
AutoCAD SHX Text
BRANCH CHIEF
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
EDITED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
A/E PROJECT NO:
AutoCAD SHX Text
CAD FILE NAME:
AutoCAD SHX Text
SHEET TITLE
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
PLOT SCALE:
AutoCAD SHX Text
MARK
AutoCAD SHX Text
ISSUE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text R
AutoCAD SHX Text D
AutoCAD SHX Text G
AutoCAD SHX Text U
AutoCAD SHX Text A
AutoCAD SHX Text O
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text
REGISTERED
AutoCAD SHX Text
ENGINEER
AutoCAD SHX Text
PROFESSIONAL
AutoCAD SHX Text
ARKANSAS
AutoCAD SHX Text E
AutoCAD SHX Text
NO. 5838
AutoCAD SHX Text W
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text L
AutoCAD SHX Text D.
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text Y
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text M
RJCaruso SAM Proj No for Const
RJCaruso CMS Stamp
File details come from the government source that posted it. Updated .