17-PFC024_James_Hall_Str_Repairs_Drawings_22.pdf
PDF 265 KB Posted
- Solicitation number
- HSCG83-17-B-PFC024
About this file
USCG Reference Drawing T-6862-AD
View the file
Other files
Show 40 more
Latest 50 of 74 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GRAPHIC SCALE
ENLARGED TYP. PANEL LAYOUT
DETAIL SECTION
DETAIL
DETAIL
DETAIL
DETAIL
AutoCAD SHX Text 4"x4"x "x4" CLIP ANGLE 38"x4" CLIP ANGLE ANCHORED WITH " EXPANSION 12" EXPANSION ANCHORS. (2) ANGLES AT THE BASE AND TOP OF EACH PANEL.
AutoCAD SHX Text
SEALANT WITH BACKER ROD
AutoCAD SHX Text 1"x3" DENSE NEOPRENE RUBBER GASKET (DENSITY 80) SET IN ADHESIVE.
AutoCAD SHX Text
PRE-CAST CONCRETE PANEL AS SPECIFIED
AutoCAD SHX Text
PRE-CAST CONCRETE PANEL AS SPECIFIED
AutoCAD SHX Text 4"x4"x "x4" CLIP ANGLE 38"x4" CLIP ANGLE ANCHORED WITH " EXPANSION 12" EXPANSION ANCHORS. (2) ANGLES AT THE BASE AND TOP OF EACH PANEL.
AutoCAD SHX Text
SEALANT WITH BACKER ROD
AutoCAD SHX Text 1"x3" DENSE NEOPRENE RUBBER GASKET (DENSITY 80) SET IN ADHESIVE.
AutoCAD SHX Text
SECOND FLOOR: 10'-0"
AutoCAD SHX Text
FIRST FLOOR: 0'-0"
AutoCAD SHX Text
EXISTING FLOOR SLAB TO REMAIN
AutoCAD SHX Text
NEW FLOOR SLAB SEE STRUCTURAL
AutoCAD SHX Text
QUARRY TILE AS SCHEDULED
AutoCAD SHX Text
MORTAR BED
AutoCAD SHX Text 4"x4"x "x4" CLIP ANGLE 38"x4" CLIP ANGLE ANCHORED WITH " EXPANSION 12" EXPANSION ANCHORS. (2) ANGLES AT THE BASE AND TOP OF EACH PANEL. MAINTAIN MINIMUM 3" SPACING FROM EDGE OF PANEL TO CENTER OF ANCHOR.
AutoCAD SHX Text 4"x4"x "x4" CLIP ANGLE 38"x4" CLIP ANGLE ANCHORED WITH " EXPANSION 12" EXPANSION ANCHORS. (2) ANGLES AT THE BASE AND TOP OF EACH PANEL. MAINTAIN MINIMUM 3" SPACING FROM EDGE OF PANEL TO CENTER OF ANCHOR.
AutoCAD SHX Text
PRE-CAST CONCRETE PANEL AS SPECIFIED
AutoCAD SHX Text
SEALANT
AutoCAD SHX Text
SEALANT
AutoCAD SHX Text
PRE-CAST CONCRETE PANEL AS SPECIFIED
AutoCAD SHX Text
"L" CASING BEAD
AutoCAD SHX Text
ALUMINUM GLAZED FRAME AS SCHEDULED
AutoCAD SHX Text 4"x4"x "x4" CLIP ANGLE 38"x4" CLIP ANGLE ANCHORED WITH " EXPANSION 12" EXPANSION ANCHORS. (2) ANGLES AT THE BASE AND TOP OF EACH PANEL.
AutoCAD SHX Text
58" IMPACT RESISTANT GYPSUM BOARD
AutoCAD SHX Text
ALUMINUM GLAZED FRAME AS SCHEDULED
AutoCAD SHX Text
PORCELAIN TILE
AutoCAD SHX Text
3 " 24GA. STUD @ 16" O.C.58" 24GA. STUD @ 16" O.C.
AutoCAD SHX Text
PRE-CAST CONCRETE PANEL AS SPECIFIED
AutoCAD SHX Text
(2) 3 " 24GA. WITH 58" 24GA. WITH (2) 3 " 24 GA. CHANNEL. 1316" 24 GA. CHANNEL.
AutoCAD SHX Text
SOUND BATT INSULATION
AutoCAD SHX Text
SECOND FLOOR: 10'-0"
AutoCAD SHX Text
FIRST FLOOR: 0'-0"
AutoCAD SHX Text
INTERIOR
AutoCAD SHX Text
EXTERIOR
AutoCAD SHX Text 4"x4"x "x4" CLIP ANGLE 38"x4" CLIP ANGLE ANCHORED WITH " EXPANSION 12" EXPANSION ANCHORS. (2) ANGLES AT THE BASE AND TOP OF EACH PANEL.
AutoCAD SHX Text PRE-CAST CONCRETE PANEL WITH EXPOSED AGGREGATE AT EXTERIOR FACE AND POLISHED AT ALL INTERIOR FACES
AutoCAD SHX Text
EXISTING COLUMN
AutoCAD SHX Text
EXISTING COLUMN
AutoCAD SHX Text
ALUMINUM GLAZED FRAME AS SCHEDULED
AutoCAD SHX Text PRE-CAST CONCRETE PANEL WITH EXPOSED AGGREGATE AT EXTERIOR FACE AND POLISHED AT ALL INTERIOR FACES
AutoCAD SHX Text 4"x4"x "x4" CLIP ANGLE 38"x4" CLIP ANGLE ANCHORED WITH " EXPANSION 12" EXPANSION ANCHORS. (2) ANGLES AT THE BASE AND TOP OF EACH PANEL.
AutoCAD SHX Text 4"x4"x "x4" CLIP ANGLE 38"x4" CLIP ANGLE ANCHORED WITH " EXPANSION 12" EXPANSION ANCHORS. (2) ANGLES AT THE BASE AND TOP OF EACH PANEL.
AutoCAD SHX Text
AutoCAD SHX Text A401
AutoCAD SHX Text
AutoCAD SHX Text A401
AutoCAD SHX Text
AutoCAD SHX Text A401
AutoCAD SHX Text
AutoCAD SHX Text A401
AutoCAD SHX Text
PRECAST PANEL FINISH SCHEDULE
AutoCAD SHX Text "A"
AutoCAD SHX Text
SIDE OF PANEL WITH EXPOSED AGGREGATE
AutoCAD SHX Text "B"
AutoCAD SHX Text
SIDE OF PANEL TO BE POLISHED CONCRETE
AutoCAD SHX Text "A"
AutoCAD SHX Text "A"
AutoCAD SHX Text "A"
AutoCAD SHX Text "A"
AutoCAD SHX Text "A"
AutoCAD SHX Text "B"
AutoCAD SHX Text "A"
AutoCAD SHX Text "B"
AutoCAD SHX Text "B"
AutoCAD SHX Text "B"
AutoCAD SHX Text "B"
AutoCAD SHX Text "B"
AutoCAD SHX Text
TYPICAL PANEL REINFORCING
AutoCAD SHX Text 4x4x2.9x2.9 WIRE MESH MINIMUM " COVER.34" COVER.
AutoCAD SHX Text
CARBON PINS @ 12" O.C. EACH WAY
AutoCAD SHX Text
12" CHAMFER TYP.
AutoCAD SHX Text
AutoCAD SHX Text A401
AutoCAD SHX Text
CAPE MAY
AutoCAD SHX Text
TRAINING CENTER
AutoCAD SHX Text
U. S. COAST GUARD
AutoCAD SHX Text
USCG, TRACEN CAPE MAY
AutoCAD SHX Text
1 MUNRO AVE.
AutoCAD SHX Text
CAPE MAY, NJ 08204-5092
AutoCAD SHX Text
CMS-1476
AutoCAD SHX Text
JLF
AutoCAD SHX Text
FEJ
AutoCAD SHX Text
1:1 PS
AutoCAD SHX Text
JLF
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text
REH
AutoCAD SHX Text
BUILDING 258
AutoCAD SHX Text
TRACEN
AutoCAD SHX Text
PRECAST PANEL DETAILS
AutoCAD SHX Text
ARCHITECTURAL
AutoCAD SHX Text
NEW JERSEY
AutoCAD SHX Text
STRUCTURAL REPAIRS TO JAMES HALL
AutoCAD SHX Text
CAPE MAY
AutoCAD SHX Text 4376510
AutoCAD SHX Text
T-6862-AD
AutoCAD SHX Text A401
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text R
AutoCAD SHX Text D
AutoCAD SHX Text G
AutoCAD SHX Text U
AutoCAD SHX Text A
AutoCAD SHX Text O
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text
CONSULTANTS
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text
REVIEWED BY:
AutoCAD SHX Text
PROJECT ENG.
AutoCAD SHX Text
APPROVING OFFICER
AutoCAD SHX Text
PROJECT NUMBER
AutoCAD SHX Text
DISCIPLINE/SHT NO
AutoCAD SHX Text
REVIEWED BY:
AutoCAD SHX Text
BRANCH CHIEF
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
EDITED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
A/E PROJECT NO:
AutoCAD SHX Text
CAD FILE NAME:
AutoCAD SHX Text
SHEET TITLE
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
PLOT SCALE:
AutoCAD SHX Text
MARK
AutoCAD SHX Text
ISSUE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1/2"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text A401
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1/2"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text A401
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1-1/2"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text A401
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1-1/2"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text A401
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1-1/2"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text A401
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1-1/2"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text A401
AutoCAD SHX Text
SCALE: 1 1/2"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 1'
AutoCAD SHX Text 2'
AutoCAD SHX Text 4'
AutoCAD SHX Text
SCALE: 1/2"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text 1'
AutoCAD SHX Text 2'
AutoCAD SHX Text 8'
RJCaruso SAM Proj No for Const
RJCaruso CMS Stamp
File details come from the government source that posted it. Updated .