17-PFC024_James_Hall_Str_Repairs_Drawings_42.pdf
PDF 406 KB Posted
- Solicitation number
- HSCG83-17-B-PFC024
About this file
USCG Reference Drawings T-6882-MD
View the file
Other files
Show 40 more
Latest 50 of 74 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ABBREVIATIONS PLUMBING LEGENDGENERAL NOTES
/2 4/
AutoCAD SHX Text GENERAL NOTES 1. ALL WORK (MATERIALS, EQUIPMENT, DEVICES, COMPONENTS, ALL WORK (MATERIALS, EQUIPMENT, DEVICES, COMPONENTS, SYSTEMS, SUPPORTS, ETC.) MUST COMPLY WITH THE REQUIREMENTS OF ALL CODES, CODE AMENDMENTS, AND ORDINANCES AS USED, ADOPTED AND/OR ENFORCED BY THE LOCAL JURISDICTION, COUNTY AND STATE IN WHICH THE PROJECT IS LOCATED. WHERE INSPECTIONS ARE REQUIRED BY COR, WORK MUST NOT BE CONCEALED UNTIL INSPECTIONS AND TESTS ARE COMPLETED AND ACCEPTED. REFER TO SPECIFICATIONS FOR APPLICABLE CODES. 2. ALL WORK IS TO BE FABRICATED AND/OR ERECTED USING ALL WORK IS TO BE FABRICATED AND/OR ERECTED USING CONTRACTOR'S FIELD MEASUREMENTS FOR PROPER COORDINATION WITH WORK OF OTHER TRADES. 3. ALL CONTRACT DOCUMENTS ARE DIAGRAMMATIC AND ALL CONTRACT DOCUMENTS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENTS OR GEOMETRICAL RELATIONSHIPS OF THE WORK. THEY ARE NOT INTENDED TO SPECIFY OR SHOW EVERY OFFSET, SEQUENCE, DEVICE, OPTION, FITTING, OR COMPONENT. DO NOT SCALE DRAWINGS FOR FABRICATION PURPOSES. 4. INFORMATION AND COMPONENTS SHOWN ON DIAGRAMS OR INFORMATION AND COMPONENTS SHOWN ON DIAGRAMS OR DETAILS, BUT NOT SHOWN ON PLANS, AND VICE VERSA, MUST BE PROVIDED AS IF EXPRESSLY REQUIRED BY BOTH. 5. EXCEPT WHERE INDICATED OTHERWISE, THE NOTATION OR EXCEPT WHERE INDICATED OTHERWISE, THE NOTATION OR DESCRIPTION OF ANY ITEM IN THE CONTRACT DOCUMENTS CARRIES WITH IT THE INSTRUCTION TO FURNISH AND INSTALL THE ITEM, WHETHER OR NOT THIS INSTRUCTION IS EXPLICITLY STATED. 6. ALL WORK IS TO BE INSTALLED SO AS TO MAINTAIN ALL WORK IS TO BE INSTALLED SO AS TO MAINTAIN ANY "UL" ASSEMBLY RATINGS, FIRE RATINGS OR SMOKE BARRIER CAPABILITIES OF WALLS, PARTITIONS, FLOORS AND ROOF. REFER TO ARCHITECTURAL DRAWINGS FOR “UL” ASSEMBLIES AND RATED PARTITIONS. SEAL UL” ASSEMBLIES AND RATED PARTITIONS. SEAL ASSEMBLIES AND RATED PARTITIONS. SEAL AROUND AND PLACE UL RATED FIRE-STOP MATERIAL AT ANY PENETRATION OR DISTURBANCE OF SUCH ASSEMBLIES. COORDINATE W/ARCHITECTURAL PLANS AND GC. 7. COORDINATE PLACEMENT OF ALL WORK WITH OTHER COORDINATE PLACEMENT OF ALL WORK WITH OTHER TRADES. DO NOT LOCATE, POSITION OR INSTALL ANY WORK IN SUCH A WAY THAT SYSTEM COMPONENTS OR ACCESS DOORS WILL BE INACCESSIBLE, UNUSABLE OR UN-MAINTAINABLE AFTER CONSTRUCTION IS COMPLETED. 8. GRAVITY DRAINAGE SYSTEMS HAVE PRIORITY WITH REGARD GRAVITY DRAINAGE SYSTEMS HAVE PRIORITY WITH REGARD TO ROUTING. COORDINATE INSTALLATION OF WORK SO AS NOT TO INHIBIT THE INSTALLATION OR REQUIRED SLOPES FOR GRAVITY DRAINAGE SYSTEMS. 9. ALL WORK IS TO BE SUPPORTED FROM STRUCTURE ABOVE, ALL WORK IS TO BE SUPPORTED FROM STRUCTURE ABOVE, FROM WALLS, OR FROM THE FLOOR UNLESS OTHERWISE INDICATED. DO NOT USE THE INSTALLED WORK OF OTHER TRADES FOR SUPPORT OR BRACING. 10. REPLACE OR REPAIR ALL ARCHITECTURAL FEATURES OR ANY REPLACE OR REPAIR ALL ARCHITECTURAL FEATURES OR ANY OTHER WORK REMOVED OR DAMAGED DURING THE COURSE OF THE WORK. REPAIR OR REPLACEMENT MUST, AS A MINIMUM, EQUAL ORIGINAL CONDITION. 11. ALL LOW VOLTAGE WIRING FOR CONTROLS, ETC. SHALL BE ALL LOW VOLTAGE WIRING FOR CONTROLS, ETC. SHALL BE INSTALLED IN CONDUIT. MATERIALS AND INSTALLATION MUST COMPLY WITH NEC, NFPA, STATE AND LOCAL CODES AND ORDINANCES. 12. ALL MECHANICAL RELATED PIPES THAT PASS THRU ALL MECHANICAL RELATED PIPES THAT PASS THRU CONCRETE, MASONRY, METAL OR WOOD CONSTRUCTION (WALLS, FLOORS, ETC.) ARE TO BE PROVIDED WITH METAL SLEEVES OR THIMBLES. SLEEVES AND THIMBLES SHALL BE AT LEAST 3/8 INCH LARGER THAN THE OUTSIDE DIAMETER OF THE PIPING PLUS INSULATION. INSTALL FIRE STOP MATERIAL WHERE PENETRATIONS OCCUR AT FIRED RATED PARTITIONS, OTHERWISE, CAULK BETWEEN SLEEVE AND PIPE WITH FLEXIBLE CAULKING MATERIAL (RATED FOR SURFACE TEMPERATURE OF PIPE OR INSULATION) TO ALLOW MOVEMENT OF PIPE. 13. IF IT BECOMES NECESSARY DURING DEMOLITION TO IF IT BECOMES NECESSARY DURING DEMOLITION TO TEMPORARILY REMOVE ANY EXISTING WORK NOT SPECIFICALLY NOTED TO BE REMOVED OR RELOCATED (THEREBY IMPLYING THAT THEY ARE TO BE LEFT FOR FUTURE USE), THE CONTRACTOR MUST REINSTALL SAID WORK TO FULLY OPERABLE CONDITION IN THEIR ORIGINAL LOCATIONS. 14. ANY EXISTING WORK DESIGNATED TO BE REUSED WHICH IS ANY EXISTING WORK DESIGNATED TO BE REUSED WHICH IS FOUND TO BE DAMAGED OR NON-OPERABLE MUST BE BROUGHT TO THE ATTENTION OF THE COR IMMEDIATELY. INSPECT THE EXISTING SYSTEM AND NOTIFY THE COR OF ANY UNUSUAL, DAMAGED, OR NON-OPERATING CONDITIONS APPLICABLE TO THE EXISTING SYSTEM BEFORE PROCEEDING WITH RELATED WORK. 15. MAINTAIN MARKED AS-BUILTS THAT INDICATE FINAL ROUTING MAINTAIN MARKED AS-BUILTS THAT INDICATE FINAL ROUTING OF ALL VALVES, BELOW GRADE PIPING, ETC. 16. REFER TO ARCHITECTURAL SHEETS FOR LOCATIONS OF ANY REFER TO ARCHITECTURAL SHEETS FOR LOCATIONS OF ANY RATED WALLS. SEAL ALL NEW PENETRATIONS THRU RATED WALLS WITH FIRESTOP. 17. ALL CW, HW AND HWR PIPES ARE TO BE EXTERNALLY ALL CW, HW AND HWR PIPES ARE TO BE EXTERNALLY INSULATED UNLESS OTHERWISE INDICATED. 18. IF DRAWINGS AND SPECIFICATION DISAGREE OR HAVE IF DRAWINGS AND SPECIFICATION DISAGREE OR HAVE CONFLICTING INFORMATION OR REQUIREMENTS, CONTACT THE CONTRACTING OFFICER AND COR FOR CLARIFICATION. 19. CONTRACTOR TO LABEL ALL NEW AND EXISTING PLUMBING CONTRACTOR TO LABEL ALL NEW AND EXISTING PLUMBING AND MECHANICAL PIPING.
AutoCAD SHX Text AFF ABOVE FINISHED FLOOR ABOVE FINISHED FLOOR BAL BALANCE or BALANCING BALANCE or BALANCING BFS BOTTLE FILL STATION BOTTLE FILL STATION CD CONDENSATE DRAIN CONDENSATE DRAIN CKT CIRCUIT CIRCUIT CLG CEILING or COOLING CEILING or COOLING COR CONTRACTING OFFICER'S REPRESENTATIVE CONTRACTING OFFICER'S REPRESENTATIVE CW DOMESTIC (POTABLE) COLD WATER DOMESTIC (POTABLE) COLD WATER Cx COMMISSIONING COMMISSIONING CxA COMMISSIONING AGENT COMMISSIONING AGENT D DRAIN DRAIN DEG DEGREE(S) DEGREE(S) DF DRINKING FOUNTAIN DRINKING FOUNTAIN DIA., Ø DIAMETER DIAMETER DISC DISCONNECT DISCONNECT DOAS DEDICATED OUTSIDE AIR SYSTEM DEDICATED OUTSIDE AIR SYSTEM DT DETERGENT DETERGENT EWC ELECTRIC WATER COOLER ELECTRIC WATER COOLER EXIST EXISTING EXISTING FD FLOOR DRAIN FLOOR DRAIN FLEX FLEXIBLE FLEXIBLE FLR FLOOR FLOOR FT FOOT, FEET FOOT, FEET GC GENERAL CONTRACTOR GENERAL CONTRACTOR GPM GALLONS PER MINUTE GALLONS PER MINUTE HB HOSE BIB HOSE BIB HDR HEADER HEADER HVY HEAVY HEAVY HW DOMESTIC (POTABLE) HOT WATER DOMESTIC (POTABLE) HOT WATER HWR DOMESTIC HOT WATER RECIRC DOMESTIC HOT WATER RECIRC INTRLK INTERLOCK INTERLOCK ISO ISOLATION ISOLATION LB POUNDS WEIGHT POUNDS WEIGHT LTG LIGHTING LIGHTING MAT'L MATERIAL MATERIAL MAX MAXIMUM MAXIMUM MBH 1000'S OF BTU'S PER HOUR 1000'S OF BTU'S PER HOUR MFR MANUFACTURER MANUFACTURER MIN MINIMUM MINIMUM N/A NOT APPLICABLE NOT APPLICABLE NFWH NON FREEZE WALL HYDRANT NON FREEZE WALL HYDRANT NTS NOT TO SCALE NOT TO SCALE OVRLD OVERLOAD OVERLOAD PLMG PLUMBING PLUMBING PSI POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH QTY QUANTITY QUANTITY REPL REPLACED REPLACED RPZ REDUCED PRESSURE ZONE ASSEMBLY REDUCED PRESSURE ZONE ASSEMBLY REQD REQUIRED REQUIRED SD SHOWER DRAIN SHOWER DRAIN SERV SERVICE SERVICE SH SHOWER HEAD SHOWER HEAD SS SANITARY SEWER OR STAINLESS STEEL SANITARY SEWER OR STAINLESS STEEL SOV SHUT OFF VALVE SHUT OFF VALVE TBD TO BE DETERMINED TO BE DETERMINED T&P TEMPERATURE & PRESSURE TEMPERATURE & PRESSURE UL UNDERWRITERS LABORATORIES UNDERWRITERS LABORATORIES UR URINAL URINAL V VENT VENT VA VALVE VALVE VERT VERTICAL VERTICAL VFY VERIFY VERIFY VTR VENT THRU ROOF VENT THRU ROOF W WIDTH WIDTH W/ WITH WITH WC WATER CLOSET WATER CLOSET WH WATER HEATER WATER HEATER W/O WITHOUT WITHOUT WPD WATER PRESSURE DROP WATER PRESSURE DROP #X MULTIPLE WHERE # INDICATES QTY MULTIPLE WHERE # INDICATES QTY NOTE: CONTACT COR PRIOR TO BID REGARDING CONTACT COR PRIOR TO BID REGARDING CLARIFICATIONS NEEDED OR REGARDING UNDEFINED ABBREVIATIONS. NOT ALL ABBREVIATIONS LISTED ARE APPLICABLE TO THIS PROJECT.
AutoCAD SHX Text
PIPE TURN - UP
AutoCAD SHX Text
PIPE TURN - DOWN
AutoCAD SHX Text
PIPE TEE
AutoCAD SHX Text
EXISTING TO BE REMOVED
AutoCAD SHX Text
EXISTING TO REMAIN
AutoCAD SHX Text
NEW PLUMBING ITEM
AutoCAD SHX Text
MANUAL VALVE
AutoCAD SHX Text
CONNECT TO EXISTING
AutoCAD SHX Text
FLOOR DRAIN - SQUARE TOP
AutoCAD SHX Text FLOOR DRAIN or CLEANOUT (AS NOTED)
AutoCAD SHX Text
SHOWER DRAIN - SQUARE TOP
AutoCAD SHX Text
SHOWER HEAD
AutoCAD SHX Text
LAVATORY - COUNTER MOUNT
AutoCAD SHX Text
WATER CLOSET
AutoCAD SHX Text
URINAL
AutoCAD SHX Text
LAVATORY - WALL MOUNT
AutoCAD SHX Text
CAPE MAY
AutoCAD SHX Text
TRAINING CENTER
AutoCAD SHX Text
U. S. COAST GUARD
AutoCAD SHX Text
USCG, TRACEN CAPE MAY
AutoCAD SHX Text
1 MUNRO AVE.
AutoCAD SHX Text
CAPE MAY, NJ 08204-5092
AutoCAD SHX Text
CMS-1476
AutoCAD SHX Text
JAB
AutoCAD SHX Text
WDP
AutoCAD SHX Text
1:1 PS
AutoCAD SHX Text
JAB
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text
WDP
AutoCAD SHX Text
BUILDING 258
AutoCAD SHX Text
TRACEN
AutoCAD SHX Text
NOTES, LEGEND & ABBREV.
AutoCAD SHX Text
PLUMBING
AutoCAD SHX Text
NEW JERSEY
AutoCAD SHX Text
STRUCTURAL REPAIRS TO JAMES HALL
AutoCAD SHX Text
CAPE MAY
AutoCAD SHX Text 4376510
AutoCAD SHX Text
T-6882-MD
AutoCAD SHX Text P001
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text
CONSULTANTS
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text
REVIEWED BY:
AutoCAD SHX Text
PROJECT ENG.
AutoCAD SHX Text
APPROVING OFFICER
AutoCAD SHX Text
PROJECT NUMBER
AutoCAD SHX Text
DISCIPLINE/SHT NO
AutoCAD SHX Text
REVIEWED BY:
AutoCAD SHX Text
BRANCH CHIEF
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
EDITED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
A/E PROJECT NO:
AutoCAD SHX Text
CAD FILE NAME:
AutoCAD SHX Text
SHEET TITLE
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
PLOT SCALE:
AutoCAD SHX Text
MARK
AutoCAD SHX Text
ISSUE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text R
AutoCAD SHX Text D
AutoCAD SHX Text G
AutoCAD SHX Text U
AutoCAD SHX Text A
AutoCAD SHX Text O
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text
REGISTERED
AutoCAD SHX Text
ENGINEER
AutoCAD SHX Text
PROFESSIONAL
AutoCAD SHX Text
ARKANSAS
AutoCAD SHX Text E
AutoCAD SHX Text
NO. 5838
AutoCAD SHX Text W
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text L
AutoCAD SHX Text D.
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text Y
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text M
RJCaruso SAM Proj No for Const
RJCaruso CMS Stamp
File details come from the government source that posted it. Updated .