SOW_15-5G3_C1.pdf
PDF 163 KB Posted
- Solicitation number
- HQ0727-15-R-0017
- Issued by
-
Defense Microelectronics Activity
About this file
Statement of Work
View the file
Other files
| File | Type | Posted |
|---|---|---|
| HQ0727-15-R-0017_-_Amendment_2.doc | DOC document | |
| Fire Extinguisher | — | |
| Hallway right.JPG | JPG image | |
| Hallway left with Door to be relocated.JPG | JPG image | |
| Door Straight towards Main Hallway.JPG | JPG image | |
| Door from hallway to be widened.JPG | JPG image | |
| Questions_and_Answers.docx | DOCX document | |
| HQ0727-15-R-0017_-_Amendment_1.pdf | ||
| SOW_15-5G3 Attachment_Work_Permits_5M15G301.pdf | ||
| HQ0727-15-R-0017.pdf | ||
| Evaluation_Criteria_5M15G301.pdf |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF WORK (SOW)
DMEA 15-5G3
9 June 2015 Project Engineer/Contract Officer Representative: David Elliott, DMEA/MECA, (916) 231-1629
1.0 SCOPE:
1.1 TITLE: Fire door and Bi-fold Door Replacement (Enlargement)
1.2 APPLICABILITY: DMEA Fire door/Bi-fold door
1.3 BACKGROUND:
1.4 PURPOSE: The purpose of this SOW is to replace/Enlarge Fire door & Replace bi-fold door with security access control system
2.0 REFERENCE GOVERNMENT PROVIDED RESOURCES:
2.1 GOVERNMENT DOCUMENTS:
Document No. Date Title UFC 3-600-01 1 Mar 2013 Fire Protection Engineering for Facilities Requirements (Change 3) https://www.wbdg.org/ccb/DOD/UFC/ufc_3_600_01.pdf UFGS-01 57 April 2006 Environments Protection Requirements http://www.wbdg.org/ccb/DOD/UFGS/UFGS%2001%2057%2020.00%2 010.pdf
UFGS-01 35 August
Governmental Safety Requirements (Change 2) http://www.wbdg.org/ccb/DOD/UFGS/UFGS%2001%2035%2026.pdf
3.0 REQUIREMENTS:
3.1 TASK REQUIREMENTS: The contractor shall perform the requirements as outlined below:
1. Fire door
a. Remove existing fire door and replace with widest double door fire door that will work in given space
i. Cut concrete wall
ii. Relocate electrical work
b. New fire door hardware must match existing DMEA door hardware
i. Von Duprin 99L Rim Exit Devices with Lever Trim, brushed stainless/nickel to match the access control system (Section 3.2.3)
ii. Hes Electronic Door Strikes that include an open/close sensor (HES model number HES 9500-606-LBM).
iii. HES strikes need to be wired to the nearest DMEA Access Control System panel with minimum 18 gage wiring.
1. Badge proximity card access to either door
a. Compliant with Avigilon access control system and HID 0008P proximity cards
iv. BEST IC cores.
c. New fire door will be held continuously open with magnets that release when fire and gas alarms activate
d. At least one of the two doors on the fire door must meet Americans with Disabilities Act (ADA) compliancy. If, due to space constraints only one of the two doors meets ADA compliance standards, the ADA-compliant door will be located on the west side of hallway https://www.wbdg.org/ccb/DOD/UFC/ufc_3_600_01.pdf http://www.wbdg.org/ccb/DOD/UFGS/UFGS%2001%2057%2020.00%2010.pdf http://www.wbdg.org/ccb/DOD/UFGS/UFGS%2001%2057%2020.00%2010.pdf http://www.wbdg.org/ccb/DOD/UFGS/UFGS%2001%2035%2026.pdf
e. Both doors must have panic/emergency hardware
f. Both doors must be compliant with UFC 3-600-01
g. Fire doors must have the fire rating label affixed (not painted over or missing) on the door
h. Fire door and frame will be painted with PTC – Frame Tan PPG 6-1510 Semi-gloss to match current DMEA fire doors and frames
2) Access Control System
a. Two lanes
i. West side of hallway lane ADA compliant
ii. East side of hallway lane minimal opening width of 26”
b. Badge proximity card access compliant with Avigilon access control system and HID 0008P proximity cards
c. No badge - Free out
d. Minimum barrier speed of operation < 1 second
e. Minimum 1 person per second throughput - Typical through put of 40 people per minute
f. Required casing (pedestals) to be in brushed stainless steel finish or brushed nickel finish
g. Required top of pedestals to be in brushed stainless steel finish or brushed nickel finish
h. Required card readers to be located on the front of the unit near the top
i. Required retracting or swinging glass barriers
j. Maximum retracting or swinging glass barrier height from ground of 42” with a minimum of 33” height from ground
k. Maximum height from the ground to the bottom of the retracting/swinging glass barrier will be no greater than 12”
l. Maximum pedestal height of 42”
m. Access system must be capable of controlling traffic flow while maximizing throughput.
n. Barriers stay open while additional authorized people walk through - even if they are walking in the opposite direction.
o. Access system must accurately differentiate between body mass and small objects (i.e. umbrellas, shoulder bags, etc.)
p. Must have at least 8 safety beams designed to stop the barriers from moving in the event that any of the beams are broken.
q. Must have a fire alarm input that allows for unimpeded emergency egress. Units must be configured to fail safe in the event of power fail.
iii. Must have at least a minimum of 24 beam IR detection matrix to provide tailgate detection and deterrence
1. Capable of detecting tailgaters at a minimum distance of 5mm behind authorized users
r. Pedestals required to be UL 2593 compliant
s. Pedestal niches to be minimalized as much as possible while maintaining compliance with the manufactures pedestal required installation guidelines
t. Pedestals located in niches required to be flush with hallway 126 walls
u. Pedestals to protrude into Hallway 107 the minimum distance possible while maintaining fire doors being propped open and not interfering
3) All work conducted on this contract that disrupts flow of DMEA personnel through hallway shall be conducted outside of normal business hours for DMEA (6am-6pm
Monday-Friday). In accordance with section 4.3 work restrictions, background checks must be completed prior to ANY work being conducted on site. The contractor shall assist the COR in completing DMEA form(s), if needed, covering areas such as hot work, odorous work, electrical work, and/or confined space.
4) The contractor shall test and certify that fire doors close upon fire/gas alarm activation and access control system fails to safe in event of power failure.
5) The contractor shall dispose/remove from site all parts, trash, and debris at the completion of work, and shall thoroughly clean the work area before leaving the site.
Representation of requirement
Figure 1
Figure 2
Recommended: Fastlane 150 or 400 model
Hallway 107
Hallway 126
3.2 Employee Attire, Identification and Safety Equipment: The contractor personnel shall wear appropriate attire and safety equipment for the work to be performed. The contractor personnel shall be neat in appearance and fully clothed (shirts, blouses, trousers, overalls or coveralls). Clothing shall be worn during the execution of their duties under this SOW.
3.3 Conflict of Interest: The contractor shall not employ any person who is an employee of the US Government if employing that person would create a conflict of interest. The contractor shall not employ any person who is an employee of the Defense Microelectronics Activity, McClellan either military or civilian, unless such person seeks and receives approval of DMEA Staff Counsel.
3.4 Code Compliance: The contractor shall abide by the most current State of California building codes for all work, including National Electrical Code and National Fire Protection Association (NFPA) standards. DMEA will inform the contractor of any work accomplished under this SOW found by DMEA, or DMEA third party certified professional inspectors, that do not meet code within 12 months following completion. DMEA will hire a professional engineering firm to conduct code compliance visits as part of an annual safety inspection. Code compliance issues shall be reviewed by the contractor’s service manager and corrected promptly at no additional cost to DMEA. Code compliance shall be checked against codes in place at the time of installation. COR acceptance of the work does not relieve the contractor of the contractor’s responsibility for code compliance.
3.5 Work Restrictions: The contractor shall abide to the following requirements listed below:
1) As a DoD facility, all contractor on-site personnel must be US citizens.
2) The DMEA facility is access controlled. All contractor personnel are required to pass a background check in advance of working at the site. The contractor shall submit background check release forms and badge requests forms for all personnel expected to work on this project at least 2 weeks prior to contract start. The on-site contractor personnel shall be issued a badge each day while on site and shall return their badges to DMEA security personnel at the end of the day or when leaving the site. Any contractor personnel showing up at DMEA without a pre-arranged badge request and background check shall not be allowed to access the DMEA facility. For security and facility access purposes, the contractor shall assign specific technicians to the DMEA work.
a) Badge Request Required Information
i) Name(s) of individuals
ii) Company
iii) Phone number
iv) Job Title
v) U.S. Citizen (Required)
b) Background Check
i) NCIC Criminal Background Check and a Terrorism Screening Database Check
- Time/Date setup with DMEA security for involved party (i.e. Maintenance personnel) to arrive for fingerprints – Valid Government Issued ID and/or passport required
3) All work under this SOW shall be coordinated with a member of the DMEA Facility Team and/or Security Team (Facility Engineer, COR, Facility Technicians, Security Professionals) to keep the DMEA Facility/Security Team aware of contractor activities. Space in the back lots of Building 1 & 2 is very tight; therefore, the contractor shall not park in the back lots at any time. Parking in the central lot is available (54th Street)
3.6 Safety: The contractor shall perform the safety requirements listed below:
1) The contractor shall provide and use safety cones/signs alerting DMEA personnel when work is being performed. The contractor shall not leave any electrical boxes open and unattended and shall use safety cones and signs when hazards are present.
2) Damage to Finishes and Property: Building finishes or government or private property soiled or damaged due to the contractor's operations shall be cleaned, repaired, replaced, or restored to condition not less than that existing immediately prior to the damage and without cost to the Government. Repeated damage to Government or private property shall, at the discretion of DMEA, be reason for default action under the terms of the contract.
3) Cleanup: All contractor supplies, equipment, and tools shall be kept out of traffic lanes or other areas where they might be a safety hazard except when their use is absolutely essential for the performance of the repairs being made, and the area is properly coned off to reduce the hazard. The contractor shall dispose of all parts, trash, and debris at the completion of work, and shall thoroughly clean the work area before leaving the site.
3.7 Proposal Requirements: The contractor shall provide the following items below:
a. Provide a copy of the California Contractors license/license number.
b. Provide a cost breakdown for materials and labor.
c. Provide a schedule/timeline for completion of the work.