HIG 1st Floor.pdf

PDF 346 KB Posted

Attached to
Student Life Housekeeping Services
Solicitation number
64-830
Issued by
Buncombe County, North Carolina

About this file

This file is a floor plan layout document for the first floor of the Highsmith building at UNC Asheville, related to the university's RFP 64-830 for Student Life Housekeeping Services. The layout depicts the spatial configuration of approximately 2,075 square feet across the first floor, identifying 129 numbered rooms and spaces including offices, meeting rooms, restrooms, storage areas, break rooms, and common areas such as a bookstore, café, lounge, and game room. The plan indicates the locations of three stairwells (A, C, E, and F) and an elevator to facilitate access and movement throughout the floor. This architectural documentation serves as a reference for understanding the physical scope of the Student Life areas subject to the housekeeping and porter services contract, which is due for proposal submission on August 3, 2026.

The floor plan provides essential spatial context for contractors bidding on the housekeeping services, as it delineates the specific areas requiring daily cleaning, maintenance, and porter duties. Understanding the layout, room types, and total square footage is critical for contractors to accurately assess labor requirements, develop cleaning schedules, and prepare competitive pricing proposals. The detailed room inventory—including high-traffic areas such as the café, bookstore, and common spaces, along with support facilities—enables bidders to determine material and equipment needs and establish realistic performance timelines for the completion of assigned housekeeping tasks across the four designated Student Life areas on campus.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

UP

UP

E X

TE

R

IO

R

IN

TE

R

IO

R

2075.5

SAIL OFFICE

726 SF

TRANSITION &

PARENT

PROGRAM

757 SF

VETERANS

136 SF

OFFICE

117A

117 SF

OFFICE

117B

159 SF

OFFICE

118A

CAFE

100.003

MAILROOM

Room 104D

CONCESSIONS

108A

Stair C

LOUNGE

100.006

ROOM

MEETING

CORRIDOR

100.002

MEETING

MEETING

OFFICE

101A

BOOKSTORE

SAFE

101F

STORE

MANAGER

101E

UNIV.

BOOKSTORE

105A

OFFICE

MANAGER

101D

FITTING

101C

ELECTRICAL

103A

MECHANICAL

ENTRY

ROOM

102A

TOILET

104B

MECH.

104C

BREAK

104A

CORRIDOR

EVENT

110A

TOILET

110B

ROOM

110C

STORAGE

ROOM

111E

STORAGE

111D

JAN

111C

TOILET

111B

VESTIBULE

115B

MGR

111F

STORAGE

110G

BULK MAILING

SUPERVISOR

115F SECURITY

115C ROOM

115D

TOILET

114E

CLERK

115G

ROOM

111A

MULTIPURPOSE

ROOM

100.005

ROOM

100.004

ROOM

MEN RR

WOMEN RR

STORAGE

JAN

GROTTO

STORAGE

STORAGE

114A

Room

ROOM

102B

ROOM

102C

ROOM

100.001

MAILROOM

STAIR

E

ELEVATOR

OFFICE

116 B

Room

Jan 115A

GAME ROOM

SUPPORT

(ROOM UNDER

STAIRS)

OFFICE

OFFICE

116A

OFFICE

OFFICE

Stair F

Stair A

HIGHSMITH

NOT TO SCALE

PLAN NORTH

First Floor

Sheets and Views
HIG 1st Floor-Layout

File details come from the government source that posted it. Updated .