South Bend-Equip-Inventory 3-2012.pdf
PDF 979 KB Posted
- Attached to
- Operations & Mechanical Maintenance Services Federal contract opportunity
- Solicitation number
- GS05P12SID0056
About this file
South Bend Inventory
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| EC10E1142 - Hammond Courthouse Final O M | — | |
| Hammond Drawings.pdf | ||
| Hammond CH Equipment.pdf | ||
| Hammond TENANT Equipment.pdf | ||
| Hammond TENANT Equipment1.pdf | ||
| Atrium Beam Detectors.pdf | ||
| South Bend HVAC Schedules.pdf | ||
| South Bend Inv. Tenant Equipment.pdf | ||
| AMD 002.pdf | ||
| Hammond Inv.pdf | ||
| Cooling Tower.xlsx | XLSX spreadsheet | |
| SIGN-IN SHEET.pdf | ||
| AMD 001.pdf | ||
| Indiana O M.pdf |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BUILDING IN0096ZZ
EQUIPMENT INVENTORY LIST Robert A. Grant Federal Courthouse, South Bend, IN.
FIELD OFFICE DATE 4/27/2009 PREPARED BY
Northwest Indiana
PM EQUIPMENT
GUIDE NUMBER LOCATION DESCRIPTION AND REMARKS
NUMBER
A-3 A-3-1 Thru-out Bldg Humidification System, Steam mfg. Trane, 110 lbs/hr
A-3-2 Thru-out Bldg Humidification System, Steam mfg. Trane, 110 lbs/hr
A-3-3 Thru-out Bldg Humidification System, Steam mfg. Trane, 110 lbs/hr
A-3-4 Thru-out Bldg Humidification System, Steam mfg. Trane, 110 lbs/hr
A-4 A-4-1 Boiler room Air Compressor w/Tank, Mfg Quince, 5HP, 208V
A-4-2 Boiler room Air Compressor w/Tank, Mfg Quince, 5HP, 208V
A-6 A-6-1 2nd Floor Air Conditioning Package Unit,5 ton, Mfg. Carrier, Judges Chambers - 1989
A-6-2 3rd Floor Air Conditioning Package Unit,5 ton, Mfg. Carrier, Judges Chambers - 1989
A-6-3 Room 238 Air Conditioning Package Unit,3 ton, Mfg. Liebert, Computer rm. - 1991
A-6-4 2nd Floor Air Conditioning Package Unit,2 ton, Mfg. Oceanaire, U.S. Attorney - 2002
A-9 A-9-1 Roof Air Cooled Condenser 3.5 ton 1/3 HP Mfg. Trane, Motor 230V
A-9-2 Roof Air Cooled Condenser 5 ton 1.5 HP Mfg. Trane, Motor 230V
A-9-3 & 4 Roof Air Cooled Condenser 5 ton 2 HP Mfg. Carrier
A-9-5 & 6 Room 238 Air Cooled Condenser 3 ton 1/3 HP Mfg. Liebert, Motor 230V
A-11 A-11-1 Penthouse Air Handler, Mfg. Carrier, 20,000 CFM
A-11-2 Roof MC Room Air Handler, Mfg. Carrier, 3,000 CFM
A-11-3 3rd Floor Air Handler, Mfg. Carrier, 12,000 CFM
A-11-4 2nd Floor Air Handler, Mfg. Carrier, 16,000 CFM
A-11-5 Room 238 Air Handler, Mfg. Carrier, 3,000 CFM
A-11-6 2nd Floor Air Handler, Mfg. Carrier, 3,000 CFM
Jim Morrison
A-11-6 2nd Floor Air Handler, Mfg. Carrier, 3,000 CFM
A-11-7 1st Floor Air Handler, Mfg. Carrier, 15265 CFM
A-11-8 1st Floor CT Air Handler, Mfg. Carrier, 3,000 CFM
A-11-9 & 10 Basement Air Handler, Mfg. Carrier, 7,000 CFM
B-2 B-1-1 & 2 Boiler Room Boiler, Gas Fired, 15 HP, Mfg. LES, 15 psi, Steam
B-3 B-3-1 & 2 Boiler Room Burner, Gas, Mfg. Gordon Platt, 2520 MBTUH
C-3 C-3-1 Roof Coils,Heating, Trane, BWH 1789-43309 added in 1989
C-3-2 2nd Floor MC Coils, Heating, 2652 sq ft, Mfg. Trane, BWH 760P00A1 added in 1989
C-3-3 Room 238 Coils, Heating, 2298 sq ft, Mfg. Trane, BWH 748A100A1 added in 1989
C-5 C-5-1 3rd Floor Auto Pneumatic Mixing Box - 60" x 24"
C-5-2 2nd Floor Auto Pneumatic Mixing Box - 480" x 38"
C-5-3 1st Floor Auto Pneumatic Mixing Box - 60" x 30"
C-5-4 1stFloor CT Auto Pneumatic Mixing Box - 40" x 20"
C-6 C-6-1 thru 147 Thru-out Bldg Controls, Central System, Mfg. Johnson 147 Controls
C-7 C-7-1 to 4 Boiler room Vacuum pumps, Mfg. Bell and Gossett, 3 HP, P-411
C-8 C-8-1 & 2 Boiler room Central Control panel, Electric Mfg. G.E.
C-8-3 & 4 Roof Central Control panel, Electric Mfg. Dunham-Bush
C-9 C-9-1 Roof Air Cooling Tower, Mfg. Trane, 155 Tons
D-1 D-1-1 Dock Overhead Power Door, Mfg. Overhead Door Company
D-3 D-3-1 to 18 Roof 18 Roof Drains
D-4 D-4-1 to 18 1st Floor Doors Main Entrance, Bronze, Mfg. Keicher Metal Arts
D-6 D-6-1 to 13 Dr. & Garage Areaway and Driveway Drains
E-17 E-17-1 to 23 Thru-out Bldg Expansion Joints in Piping 2 inch
E-19 E-19-1 to 176 Thru-out Bldg Emergency Lights, Battery, 2 Lamp, 4 ft
New outer doors 12/2008
FIELD OFFICE DATE 4/27/2009 PREPARED BY
Northwest Indiana
PM EQUIPMENT
GUIDE NUMBER LOCATION DESCRIPTION AND REMARKS
NUMBER
E-26 E-26-1 Roof LV Molded Case Breaker, ITE NEMA 3R 600V 1200 AMP
E-27 E-27-1 & 2 Basement LV Power Circuit Breaker, ITE 3 Phase 120/208V - 1200 Amp
E-27-3 &4 Basement LV Power Circuit Breaker, ITE 3 Phase 120/208V - 800 Amp
E-27-5 & 9 Basement LV Power Circuit Breaker, ITE 3 Phase 120/208V - 400 Amp
E-27-10 to 26 Basement LV Power Circuit Breaker, ITE 3 Phase 120/208V - 200 Amp
E-27-27 to 30 Basement LV Power Circuit Breaker, ITE 3 Phase 120/208V - 175 Amp
E-27-31 to 40 Basement LV Power Circuit Breaker, ITE 3 Phase 120/208V - 100 Amp
E-27-41 & 42 Basement LV Power Circuit Breaker, ITE 3 Phase 120/208V - 225 Amp
E-28 E-28-1 Roof ITE Motor Starter, 460V, 50HP
E-30 E-30-1 & 2 Basement Main Switchboard, 2 Cubicles, Mfg. G.E., 4000 Amp, 120/208V
E-30-3 Basement Main Switchboard, 1 Cubicle, Mfg. ITE., 1200 Amp, 120V
E-30-4 Basement Main Switchboard, 1 Cubicle, Mfg. ITE., 800 Amp, 120/208V
E-30-5 Basement Main Switchboard, 1 Cubicle, Mfg. G.E., 400 Amp, 120/208V
E-30-6 Basement Main Switchboard, 1 Cubicle, Mfg. Powerlite, 600 Amp, 250V
E-34 E-34-1 to 9 Basement Disconnects, 3 Phase, Mfg. Square D, 480V, 600 Amp
Basement
E-34-10 to 18 Thru-out Bldg Disconnects, 3 Phase, Mfg. Square D, 120/208V, 100 Amp
E-34-19 to 25 Thru-out Bldg Disconnects, 3 Phase, Mfg. Square D, 120/208V, 60 Amp
E-34-26 to 35 Thru-out Bldg Disconnects, 3 Phase, Mfg. Square D, 120/208V, 30 Amp
E-35 E-35-1 to 27 Thru-out Bldg Motor Control Center, Mfg. Johnson, Size 2, 3 Phase
F-8 F-8-1 to 18 Thru-out Bldg Fire Hose Cabinet
F-9 F-9-1 to 19 Thru-out Bldg Fire Department Hose Connections, 1-1/2" Standpipe Outlet
F-10 F-10-1 North Center Fire Department Pumper Connections, 2-1/2" Siamese
F-11 F-11-1 to 22 Thru-out Bldg Fire Doors, Stairwell and Exit ways
Transfer Switch & panel installed 5/2009
Jim Morrison
F-11 F-11-1 to 22 Thru-out Bldg Fire Doors, Stairwell and Exit ways
F-1 F-1-1 Basement Alarm Check Valve, 80 PSI, 6 inch
F-4 F-1-1 & 2 Basement Fire Control Valve, 6 inch, Wet System
F-1 F-1-1 Basement Alarm Check Valve, 80 PSI, 6 inch
F-1 F-1-1 Basement Alarm Check Valve, 80 PSI, 6 inch
F-14-14 to 19 Thru-out Bldg Automatic Fire Detection or Alarm Devices, Heat Detectors
F-17 F-17-1 to 27 Thru-out Bldg Fire Alarm Boxes, Manual Pull, Mfg. Edwards, Coded
F-20 F-20-1 to 34 Basement Sprinkler Heads - Sprinkler Area 34,000 Sq. Ft. 3/4 of Basement
F-22 F-22-1 to 30 Thru-out Bldg Fire Extinguisher Stored Pressure w/Gauge 10 lbs.
F-24 F-24-1 to 30 Thru-out Bldg Fire Extinguisher Stored Pressure w/Gauge 10 lbs.
F-25 F-25-1 to 30 Thru-out Bldg Fire Extinguisher Stored Pressure w/Gauge 10 lbs.
F-27 F-27-1 & 2 1st Floor Fan Centrifugal, Exhaust, Mfg. Trane, 75 CFM, 1/8 HP
F-27-3 Roof East Fan Centrifugal, Exhaust, Mfg. Trane, 75 CFM, 1/6 HP
F-27-4 Roof S/E Fan Centrifugal, Exhaust, Mfg. Trane, 150 CFM, 1/3 HP
F-27-5 Roof N/W Fan Centrifugal, Exhaust, Mfg. Trane, 150 CFM, 1/4 HP
F-27-6 Roof East Fan Centrifugal, Exhaust, Mfg. Trane, 250 CFM, 1/3 HP
F-27-7 Dock Center Fan Centrifugal, Exhaust, Mfg. Trane, 300 CFM, 1/2 HP
F-27-8 Roof Fan Centrifugal, Exhaust, Mfg. Trane, 415 CFM, 1/2 HP
F-27-9 1st Floor Fan Centrifugal, Exhaust, Mfg. Trane, 570 CFM, 1/4 HP
F-27-10 2nd Floor Fan Centrifugal, Exhaust, Mfg. Trane, 1970 CFM, 3/4 HP
F-27-11 Penthouse Fan Centrifugal, Exhaust, Mfg. Trane, 2000 CFM, 1/2 HP
F-27-12 1 Court Fan Centrifugal, Return, Mfg. Trane, 3000 CFM, 5 HP
F-27-13 Penthouse Fan Centrifugal, Exhaust, Mfg. Trane, 7000 CFM, 5 HP
F-27-14 3rd Floor Fan Centrifugal, Return, Mfg. Trane, 10640 CFM, 5 HP
F-27-15 2nd Floor Fan Centrifugal, Return, Mfg. Trane, 13935 CFM, 10 HP
F-27-16 1st Floor Fan Centrifugal, Return, Mfg. Trane, 14550 CFM, 10 HP
BUILDING IN0096ZZ
replaced with new system replaced with new system
The above (in yellow) fire detection & supperssion equipment was replaced by new equipment listed on the last 8 pages of this inventory replaced with new system replaced with new system replaced with new system replaced with new system replaced with new system
FIELD OFFICE DATE 4/27/2009 PREPARED BY
Northwest Indiana
PM EQUIPMENT
GUIDE NUMBER LOCATION DESCRIPTION AND REMARKS
NUMBER
F-27 F-27-17 Mezzanine Fan Centrifugal, Return, Mfg. Trane, 14550 CFM, 10 HP
F-27-18 Penthouse Fan Centrifugal, Return, Mfg. Trane, 570 CFM
F-27-19 Roof Fan Centrifugal, Return, Mfg. Trane, 570 CFM
F-32 F-32-1 to 12 !st & Mezz Filter Throwaway - 20" x 25" x 2"
F-32-1 to 15 1st & Mezz Filter Throwaway - 20" x 20" x 2"
F-32-1 to 12 2nd Floor Filter Throwaway - 20" x 20" x 2"
F-32-1 to 8 2nd Floor Filter Throwaway - 20" x 25" x 2"
F-32-1 to 15 3rd Floor Filter Throwaway - 20" x 20" x 2"
F-32-1 to 3 3rd Floor Filter Throwaway - 20" x 25" x 2"
F-32-1 to 6 1st Court Filter Throwaway - 20" x 25" x 2"
F-32-1 to 14 Penthouse Filter Throwaway - 20" x 16" x 2"
F-34 F-34-1 to 176 Thru-out Bldg Flourescent Lighting, 48"- 2 Tube, Louver
F-34-1 to 220 Thru-out Bldg Flourescent Lighting, 48"- 1 Tube, Diffuser
F-34-1 to 841 Thru-out Bldg Flourescent Lighting, 48"- 2 Tube, Diffuser
F-34-1 to 60 1st Floor Flourescent Lighting, 24" x 24" - 2 Lamp
F-35 F-35-1 to 176 Thru-out Bldg Flourescent Lighting, 48"- 2 Tube, Louver
F-35-1 to 220 Thru-out Bldg Flourescent Lighting, 48"- 1 Tube, Diffuser
F-35-1 to 841 Thru-out Bldg Flourescent Lighting, 48"- 2 Tube, Diffuser
F-35-1 to 60 1st Floor Flourescent Lighting, 24" x 24" - 2 Lamp
H-2 H-2-1 Boiler Room Hot Water Heater, Gas, Mfg. State, 80 Gallons
L-2 L-2-1 Dock Entrance American Lift, 1500 lb. Capacity removed Front Entrance
Upper 2nd floor
L-2-2 Dock Entrance Handicap Lift removed L-3 L-3-1 to 32 Thru-out Bldg Mercury Decorative Fixtures, 15'
Wheelchair lift
Wheelchair lift added added
Jim Morrison
L-3 L-3-1 to 32 Thru-out Bldg Mercury Decorative Fixtures, 15'
L-4 L-4-1 to 11 Dock High Pressure Sodium, 14' above ground
M-3 M-3-1 to 23 Thru-out Bldg Motors, 1 to 7.5 HP, Mfg. Gold
M-3-1 to 11 Thru-out Bldg Motors, 7.5 to 50 HP, Mfg. US
M-3-1 Roof Motors over 50 HP, Mfg. US
P-4 P-4-1 & 2 3rd Floor Chill Water Pumps, 15 HP, 310 GPM
P-4-1 & 2 Boiler Room Boiler Feed Pumps, 1.5 HP
R-1 R-1-1 to 421 Thru-out Bldg Radiators, Two Pipe System
R-2 R-2-1 Roof Roof Inspection, 27000 Sq. Ft.
R-5 R-5-1 Penthouse Reciprocal Type Chillers, Mfg. Carrier, 15 Tons, 10 HP
R-5-2 Roof Centrifugal Chiller, Mfg. Trane, 155 Tons, 7.5 HP
T-8 T-8-1 to 23 Basement 2" End of the Line Traps, Low Pressure
U-1 U-1-1 & 2 Stairwell Unit Heaters, Steam, 250 CFM, 1.5 HP
V-3 V-3-1 to 7 Thru-out Bldg 2" Regulating Valves, Chilled Water
V-5 V-5-1 to 25 Thru-out Bldg Main Line and Critical Valves
V-5-1 to 50 Thru-out Bldg Valves over 2"
V-5-1 to 18 Boiler Room 7" Critical Valve, Steam
V-5-1 & 2 Boiler Room 5" Critical Valve, Steam
V-5-1 to 5 Boiler Room 3" Critical Valve, Steam
V-5-1 to 5 Boiler Room 2" Critical Valve, Steam
V-5-1 to 4 Pump Room 4" Critical Valve, Water
V-6 V-6-1 to 3 Boiler Room Pneumatic valves, 4", 5", & 8"
V-6-1 & 2 Boiler Room Pneumatic 5" Steam valve, Zone Control
W-3 W-3-1 Boiler Room Water Softner, Mfg. Bruner, 40 Gallon Tank
Boiler Room
BUILDING IN0096ZZ
installed 5/2009Gas fired elec. Standby generator
FIELD OFFICE DATE 4/27/2009 PREPARED BY
Northwest Indiana Jim Morrison
Fire Detection & Alarm Equipment
FIELD OFFICE DATE 4/27/2009 PREPARED BY
Northwest Indiana Jim Morrison
Fire Sprinkler Equipment