Hammond Drawings.pdf

PDF 25 MB Posted

Attached to
Operations & Mechanical Maintenance Services Federal contract opportunity
Solicitation number
GS05P12SID0056
Issued by
General Services Administration Public Buildings Service

About this file

Hammond Drawings

View the file

Other files for this federal contract opportunity

Other files attached to Operations & Mechanical Maintenance Services, newest first.
File Type Posted
EC10E1142 - Hammond Courthouse Final O M —
Hammond CH Equipment.pdf PDF
Hammond TENANT Equipment.pdf PDF
Hammond TENANT Equipment1.pdf PDF
Atrium Beam Detectors.pdf PDF
South Bend HVAC Schedules.pdf PDF
South Bend Inv. Tenant Equipment.pdf PDF
AMD 002.pdf PDF
Hammond Inv.pdf PDF
Cooling Tower.xlsx XLSX spreadsheet
South Bend-Equip-Inventory 3-2012.pdf PDF
SIGN-IN SHEET.pdf PDF
AMD 001.pdf PDF
Indiana O M.pdf PDF
Show all 14

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

58 59

56 57

54 55 60 61

49 50 51 52 53

44 45 46 47

40 41

36 37

34 35

27 28

2 3

4 5

6 7

8 9

10 11

12 13 14 15

16 17 18 19

20 21 22 23

24 25

26 27

28 29

30 31

32 33

34 35

36 37

38 39

40 41

42 43

44 45

46 47

48 49

50 51

52 53

54 55

3 4

5 6

7 8

151617 18192021

282930

313233

343536

373839

464748

545556

891112

131415

161718

22 23 24

25 26 27

29 30

35 36

42 43 44 45 48

58 60

61 63

LMH-2-2

EcoSystem Loop #3 (55 Ballast Addresses)

LMH-2-2

EcoSystem Loop #2 (64 Ballast Addresses)

LMH-2-2

EcoSystem Loop #1 (63 Ballast Addresses)

LMH-2-2

EcoSystem Loop #4 (59 Ballast Addresses)

LMH-2-2

EcoSystem Loop #5 (52 Ballast Addresses)

2526272829303132

2 3 4

5 6

7 8

9 10

17 18

35 34

37 36

45 44

47 46

49 48

51 50

53 52

55 54

1 2 3 4 5 6 7

45 46

43 44

20 21

16 13 12

15 14

25 24

27 26

29 28

31 30

33 32

35 34

37 36

5 4

23 22 43 44 45

39 40

41 42

47 48

49 50

51 52

53 54

55 56 57

58 59 60

1 2 3 4 5 6 7

8 9 10 11 12 13 14

15 16 17 18 19 20 21

22 23 24 25 26

27 28 29 30 31

43444546

51 52

54 55 56

58 59

62 63

LMH-2-1

EcoSystem Loop #1

(63 Ballast Addresses)

LMH-2-1

EcoSystem Loop #2

(60 Ballast Addresses)

LMH-2-1

EcoSystem Loop #3

(58 Ballast Addresses)

LMH-2-1

EcoSystem Loop #5

(51 Ballast Addresses)

LMH-2-1

EcoSystem Loop #4 (48 Ballast Addresses)

N.I.C.

2 5

11 14

18 21

26 29

32 35

XPJ

XPJ XPJ

XPJ

XPJ XPJ

XPJ 51

59 60

Project Number:

Drawn By:

Drawing Revision:

Drawing Date:

Sheet:

Lutron Electronics Co., Inc.

7200 Suter Road | Coopersburg, PA 18036 | USA

(610) 282-3800 | fax: (610) 282-1146

US Court House

Hammond, IN

88732

KSK/BAH

3ELL1

5/20/11

Floor 2

QUANTUM

ECOSYSTEM LOOP LAYOUT

NOTE TO CONTRACTOR:

LUTRON WILL PROGRAM THE QUANTUM

SYSTEM PER THESE LOOP LAYOUTS. IF

THE SYSTEM CANNOT BE WIRED AS

SHOWN, PLEASE CONTACT LUTRON.

ECOSYSTEM LOOP CONTROLS / MODULES

EcoSystem ballast / module address number.

All ballast / modules to be wired back to the lighting management hub (LMH-X-X) noted on the loop layout.

Lutron Part: C5-XPJ-16A: EcoSystem Switching Power Module for Non-Dim Loads.

Allows integration of any load type into the EcoSystem Bus for up to 16A of load. Loads controlled through this module will not be dimmed.

Lutron Part: C5-BMJ-16A: EcoSystemTM Dimming Power Module for 3-wire Lutron Dimming Ballasts.

Allows integration of any Lutron Eco-10, Hi-Lume and compact SE ballasts into the EcoSystem Loop for up to 16A of load.

Lutron Part: EC-DIR-WH: Daylight Sensor.

This daylight sensor is designed specifically to work with Lutron's EcoSystemTM ballasts and modules to implement daylight harvesting. Requires 4 #22 AWG wires.

Lutron Part: LOS-CDT-XXXX-WH: Dual Technology Ceiling Mount Sensor. Wire to the closest EcoSystem ballast / module in the same room without the use of a power pack. Requires 3 #22 AWG wires.

THIS DRAWING IS NOT TO BE USED FOR GENERAL BUILDING WIRING

PURPOSES. ITS INTENT IS TO DISPLAY THE QUANTUM SYSTEM

COMPONENTS AND ECOSYSTEM PARTS ONLY. All EcoSystem ballast and modules should be wired to the loop that is shown. This is required for Lutron database programming purposes.

Placement of the XPJ, BMJ and BMF modules are show for illustrative purposes only and can be placed anywhere within the rooms/loops.

LUTRON LAYOUT IS BASED UPON:

Drawing By: WMA Consulting Engineers, Ltd.

Sheet No: E-3.02 Dated: 2/16/10

XPJ

BMJ

Drawing Not To Scale

**IMPORTANT NOTE REGARDING SENSOR PLACEMENT**

THE OCCUPANCY SENSORS & DAYLIGHT SENSORS ON THIS

ECOSYSTEM LOOP LAYOUT WERE NOT PLACED BY LUTRON. THIS

ECOSYSTEM LOOP LAYOUT ONLY SHOWS THE CONNECTION OF

THE SENSORS TO THE APPROPRIATE ECOSYSTEM COMPONENT.

THE ACTUAL LOCATIONS OF THE SENSORS SHOULD BE

DETERMINED BY FOLLOWING THE LUTRON SPECIFICATION SHEETS

AND THE INSTALLATION INSTRUCTIONS.

LMH-2-2

EcoSystem Loop #7

(45 Ballast Addresses)

LMH-2-1

Ecosystem Loop #7 (45 Ballast Addresses)

LMH-1-1

Ecosystem Loop #4 (35 Ballast Addresses)

LMH-1-1-3

Ecosystem Loop #1 (40 Ballast Addresses)

LMH-1-1-2

Ecosystem Loop #2 (40 Ballast Addresses)

LMH-1-1

Ecosystem Loop #5 (42 Ballast Addresses)

5 6

7 89101112

13 14

1516171819

26 27 28 29 30

31 32 33

11 12

13 14

24 25 26

27 28 29

33 34

37 38 39

A

B C

B

A

D

E

F

G

H iGF E

13 14

16 17

181920

21 22 23

24 25 26

32 33 34

35 36

373839

DL

P E

N D

/C O

V E

CA-1

TO LHM

CA-1

B

C DL

A B C

D

E

F G

H

A

BH

PEND/

COVE

G

DL

E

1 2

7 8

9101112

17 18 19 20 21

2223242526

36 37 38 39

Project Number:

Drawn By:

Drawing Revision:

Drawing Date:

Sheet:

Lutron Electronics Co., Inc.

7200 Suter Road | Coopersburg, PA 18036 | USA

(610) 282-3800 | fax: (610) 282-1146

US Court House Hammond, IN

88732

KSK/SPK

4ELL1

06/07/11

Atrium & Fourth Floor North

QUANTUM

ECOSYSTEM LOOP LAYOUT

THIS DRAWING IS NOT TO BE USED FOR GENERAL BUILDING WIRING

PURPOSES. ITS INTENT IS TO DISPLAY THE QUANTUM SYSTEM

COMPONENTS AND ECOSYSTEM PARTS ONLY. All EcoSystem ballast and modules should be wired to the loop that is shown. This is required for Lutron database programming purposes.

Placement of the XPJ, BMJ and BMF modules are show for illustrative purposes only and can be placed anywhere within the rooms/loops.

LUTRON LAYOUT IS BASED UPON:

Drawing By: WMA Consulting Engineers Sheet No: E-3.04 Dated: 2/16/10

Drawing Not To Scale

**IMPORTANT NOTE REGARDING SENSOR PLACEMENT**

THE OCCUPANCY SENSORS & DAYLIGHT SENSORS ON THIS

ECOSYSTEM LOOP LAYOUT WERE NOT PLACED BY LUTRON. THIS

ECOSYSTEM LOOP LAYOUT ONLY SHOWS THE CONNECTION OF

THE SENSORS TO THE APPROPRIATE ECOSYSTEM COMPONENT.

THE ACTUAL LOCATIONS OF THE SENSORS SHOULD BE

DETERMINED BY FOLLOWING THE LUTRON SPECIFICATION SHEETS

AND THE INSTALLATION INSTRUCTIONS.

NOTE TO CONTRACTOR:

LUTRON WILL PROGRAM THE QUANTUM

SYSTEM PER THESE LOOP LAYOUTS. IF

THE SYSTEM CANNOT BE WIRED AS

SHOWN, PLEASE CONTACT LUTRON.

ECOSYSTEM LOOP CONTROLS / MODULES

EcoSystem ballast / module address number.

All ballast / modules to be wired back to the lighting management hub (LMH-X-X) noted on the loop layout.

Lutron Part: C5-XPJ-16A: EcoSystem Switching Power Module for Non-Dim Loads.

Allows integration of any load type into the EcoSystem Bus for up to 16A of load. Loads controlled through this module will not be dimmed.

Lutron Part: C5-BMJ-16A: EcoSystemTM Dimming Power Module for 3-wire Lutron Dimming Ballasts.

Allows integration of any Lutron Eco-10, Hi-Lume and compact SE ballasts into the EcoSystem Loop for up to 16A of load.

Lutron Part: EC-DIR-WH: Daylight Sensor.

This daylight sensor is designed specifically to work with Lutron's EcoSystemTM ballasts and modules to implement daylight harvesting. Requires 4 #22 AWG wires.

Lutron Part: LOS-CDT-XXXX-WH: Dual Technology Ceiling Mount Sensor. Wire to the closest EcoSystem ballast / module in the same room without the use of a power pack. Requires 3 #22 AWG wires.

XPJ

BMJ

TAG LOCATION SERVICE HP VOLTS PH HZ MANUFACTURER REMARKS

VFD-5.1 LEVEL 5 MECHANICAL COOLING TOWER 15 480 3 60 EATON CUTLER-HAMMER 1,2,3,4

VFD-5.2 LEVEL 5 MECHANICAL COOLING TOWER 15 480 3 60 EATON CUTLER-HAMMER 1,2,3,4

VFD-5.3 LEVEL 5 MECHANICAL COOLING TOWER 15 480 3 60 EATON CUTLER-HAMMER 1,2,3,4

VFD-LL.1 LOWER LEVEL MECH RM CHW PUMP P-1 15 480 3 60 EATON CUTLER-HAMMER 2,3,4

VFD-LL.4 LOWER LEVEL MECH RM CHW PUMP P-4 15 480 3 60 EATON CUTLER-HAMMER 2,3,4

VFD-LL.6 LOWER LEVEL MECH RM CHW PUMP P-6 15 480 3 60 EATON CUTLER-HAMMER 2,3,4

VFD-LL.7 LOWER LEVEL MECH RM CHW PUMP P-7 15 480 3 60 EATON CUTLER-HAMMER 2,3,4

REMARKS:

1. VFD WITH BYPASS FURNISHED BY COOLING TOWER MANUFACTURER

2. FURNISHED BY DIVISION 23 AND INSTALLED BY DIVISION 26.

3. COORDINATE EXACT LOCATION FOR NEW VFD IN FIELD. MAINTAIN MANUFACTURER'S RECOMMENDED CLEARANCES.

4. TEMPERATURE CONTROL CONTRACTOR SHALL EXTEND EXISTING EMS TO PROVIDE HARD-WIRED INTERFACE FOR

START-STOP, MODULATION, ALARM AND STATUS

VARIABLE FREQUENCY DRIVE SCHEDULE (VFD)

58 59

56 57

54 55 60 61

49 50 51 52 53

44 45 46 47

40 41

36 37

34 35

27 28

2 3

4 5

6 7

8 9

10 11

12 13 14 15

16 17 18 19

20 21 22 23

24 25

26 27

28 29

30 31

32 33

34 35

36 37

38 39

40 41

42 43

44 45

46 47

48 49

50 51

52 53

54 55

3 4

5 6

7 8

151617 18192021

282930

313233

343536

373839

464748

545556

891112

131415

161718

22 23 24

25 26 27

29 30

35 36

42 43 44 45 48

58 60

61 63

LMH-2-2

EcoSystem Loop #3 (55 Ballast Addresses)

LMH-2-2

EcoSystem Loop #2 (64 Ballast Addresses)

LMH-2-2

EcoSystem Loop #1 (63 Ballast Addresses)

LMH-2-2

EcoSystem Loop #4 (59 Ballast Addresses)

LMH-2-2

EcoSystem Loop #5 (52 Ballast Addresses)

2526272829303132

2 3 4

5 6

7 8

9 10

17 18

35 34

37 36

45 44

47 46

49 48

51 50

53 52

55 54

1 2 3 4 5 6 7

45 46

43 44

20 21

16 13 12

15 14

25 24

27 26

29 28

31 30

33 32

35 34

37 36

5 4

23 22 43 44 45

39 40

41 42

47 48

49 50

51 52

53 54

55 56 57

58 59 60

1 2 3 4 5 6 7

8 9 10 11 12 13 14

15 16 17 18 19 20 21

22 23 24 25 26

27 28 29 30 31

43444546

51 52

54 55 56

58 59

62 63

LMH-2-1

EcoSystem Loop #1

(63 Ballast Addresses)

LMH-2-1

EcoSystem Loop #2

(60 Ballast Addresses)

LMH-2-1

EcoSystem Loop #3

(58 Ballast Addresses)

LMH-2-1

EcoSystem Loop #5

(51 Ballast Addresses)

LMH-2-1

EcoSystem Loop #4 (48 Ballast Addresses)

N.I.C.

2 5

11 14

18 21

26 29

32 35

XPJ

XPJ XPJ

XPJ

XPJ XPJ

XPJ 51

59 60

Project Number:

Drawn By:

Drawing Revision:

Drawing Date:

Sheet:

Lutron Electronics Co., Inc.

7200 Suter Road | Coopersburg, PA 18036 | USA

(610) 282-3800 | fax: (610) 282-1146

US Court House

Hammond, IN

88732

KSK/BAH

3ELL1

5/20/11

Floor 2

QUANTUM

ECOSYSTEM LOOP LAYOUT

NOTE TO CONTRACTOR:

LUTRON WILL PROGRAM THE QUANTUM

SYSTEM PER THESE LOOP LAYOUTS. IF

THE SYSTEM CANNOT BE WIRED AS

SHOWN, PLEASE CONTACT LUTRON.

ECOSYSTEM LOOP CONTROLS / MODULES

EcoSystem ballast / module address number.

All ballast / modules to be wired back to the lighting management hub (LMH-X-X) noted on the loop layout.

Lutron Part: C5-XPJ-16A: EcoSystem Switching Power Module for Non-Dim Loads.

Allows integration of any load type into the EcoSystem Bus for up to 16A of load. Loads controlled through this module will not be dimmed.

Lutron Part: C5-BMJ-16A: EcoSystemTM Dimming Power Module for 3-wire Lutron Dimming Ballasts.

Allows integration of any Lutron Eco-10, Hi-Lume and compact SE ballasts into the EcoSystem Loop for up to 16A of load.

Lutron Part: EC-DIR-WH: Daylight Sensor.

This daylight sensor is designed specifically to work with Lutron's EcoSystemTM ballasts and modules to implement daylight harvesting. Requires 4 #22 AWG wires.

Lutron Part: LOS-CDT-XXXX-WH: Dual Technology Ceiling Mount Sensor. Wire to the closest EcoSystem ballast / module in the same room without the use of a power pack. Requires 3 #22 AWG wires.

THIS DRAWING IS NOT TO BE USED FOR GENERAL BUILDING WIRING

PURPOSES. ITS INTENT IS TO DISPLAY THE QUANTUM SYSTEM

COMPONENTS AND ECOSYSTEM PARTS ONLY. All EcoSystem ballast and modules should be wired to the loop that is shown. This is required for Lutron database programming purposes.

Placement of the XPJ, BMJ and BMF modules are show for illustrative purposes only and can be placed anywhere within the rooms/loops.

LUTRON LAYOUT IS BASED UPON:

Drawing By: WMA Consulting Engineers, Ltd.

Sheet No: E-3.02 Dated: 2/16/10

XPJ

BMJ

Drawing Not To Scale

**IMPORTANT NOTE REGARDING SENSOR PLACEMENT**

THE OCCUPANCY SENSORS & DAYLIGHT SENSORS ON THIS

ECOSYSTEM LOOP LAYOUT WERE NOT PLACED BY LUTRON. THIS

ECOSYSTEM LOOP LAYOUT ONLY SHOWS THE CONNECTION OF

THE SENSORS TO THE APPROPRIATE ECOSYSTEM COMPONENT.

THE ACTUAL LOCATIONS OF THE SENSORS SHOULD BE

DETERMINED BY FOLLOWING THE LUTRON SPECIFICATION SHEETS

AND THE INSTALLATION INSTRUCTIONS.

(45 Ballast Addresses)

LMH-2-1

Ecosystem Loop #7 (45 Ballast Addresses)

LMH-1-1

Ecosystem Loop #4 (35 Ballast Addresses)

LMH-1-1-3

Ecosystem Loop #1 (40 Ballast Addresses)

LMH-1-1-2

Ecosystem Loop #2 (40 Ballast Addresses)

LMH-1-1

Ecosystem Loop #5 (42 Ballast Addresses)

5 6

7 89101112

13 14

1516171819

26 27 28 29 30

31 32 33

11 12

13 14

24 25 26

27 28 29

33 34

37 38 39

A

B C

B

A

D

E

F

G

H iGF E

13 14

16 17

181920

21 22 23

24 25 26

32 33 34

35 36

373839

DL

P E

N D

/C O

V E

CA-1

TO LHM

CA-1

B

C DL

A B C

D

E

F G

H

A

BH

PEND/

COVE

G

DL

E

1 2

7 8

9101112

17 18 19 20 21

2223242526

36 37 38 39

Project Number:

Drawn By:

Drawing Revision:

Drawing Date:

Sheet:

Lutron Electronics Co., Inc.

7200 Suter Road | Coopersburg, PA 18036 | USA

(610) 282-3800 | fax: (610) 282-1146

US Court House Hammond, IN

88732

KSK/SPK

4ELL1

06/07/11

Atrium & Fourth Floor North

QUANTUM

ECOSYSTEM LOOP LAYOUT

THIS DRAWING IS NOT TO BE USED FOR GENERAL BUILDING WIRING

PURPOSES. ITS INTENT IS TO DISPLAY THE QUANTUM SYSTEM

COMPONENTS AND ECOSYSTEM PARTS ONLY. All EcoSystem ballast and modules should be wired to the loop that is shown. This is required for Lutron database programming purposes.

Placement of the XPJ, BMJ and BMF modules are show for illustrative purposes only and can be placed anywhere within the rooms/loops.

LUTRON LAYOUT IS BASED UPON:

Drawing By: WMA Consulting Engineers Sheet No: E-3.04 Dated: 2/16/10

Drawing Not To Scale

**IMPORTANT NOTE REGARDING SENSOR PLACEMENT**

THE OCCUPANCY SENSORS & DAYLIGHT SENSORS ON THIS

ECOSYSTEM LOOP LAYOUT WERE NOT PLACED BY LUTRON. THIS

ECOSYSTEM LOOP LAYOUT ONLY SHOWS THE CONNECTION OF

THE SENSORS TO THE APPROPRIATE ECOSYSTEM COMPONENT.

THE ACTUAL LOCATIONS OF THE SENSORS SHOULD BE

DETERMINED BY FOLLOWING THE LUTRON SPECIFICATION SHEETS

AND THE INSTALLATION INSTRUCTIONS.

NOTE TO CONTRACTOR:

LUTRON WILL PROGRAM THE QUANTUM

SYSTEM PER THESE LOOP LAYOUTS. IF

THE SYSTEM CANNOT BE WIRED AS

SHOWN, PLEASE CONTACT LUTRON.

ECOSYSTEM LOOP CONTROLS / MODULES

EcoSystem ballast / module address number.

All ballast / modules to be wired back to the lighting management hub (LMH-X-X) noted on the loop layout.

Lutron Part: C5-XPJ-16A: EcoSystem Switching Power Module for Non-Dim Loads.

Allows integration of any load type into the EcoSystem Bus for up to 16A of load. Loads controlled through this module will not be dimmed.

Lutron Part: C5-BMJ-16A: EcoSystemTM Dimming Power Module for 3-wire Lutron Dimming Ballasts.

Allows integration of any Lutron Eco-10, Hi-Lume and compact SE ballasts into the EcoSystem Loop for up to 16A of load.

Lutron Part: EC-DIR-WH: Daylight Sensor.

This daylight sensor is designed specifically to work with Lutron's EcoSystemTM ballasts and modules to implement daylight harvesting. Requires 4 #22 AWG wires.

Lutron Part: LOS-CDT-XXXX-WH: Dual Technology Ceiling Mount Sensor. Wire to the closest EcoSystem ballast / module in the same room without the use of a power pack. Requires 3 #22 AWG wires.

(45 Ballast Addresses)

LMH-2-1

Ecosystem Loop #7 (45 Ballast Addresses)

Project Number:

Drawn By:

Drawing Revision:

Drawing Date:

Sheet:

Lutron Electronics Co., Inc.

7200 Suter Road | Coopersburg, PA 18036 | USA

(610) 282-3800 | fax: (610) 282-1146

US Court House Hammond, IN

88732

KSK

2ELL1

11/18/10

Atrium

QUANTUM

ECOSYSTEM LOOP LAYOUT

THIS DRAWING IS NOT TO BE USED FOR GENERAL BUILDING WIRING

PURPOSES. ITS INTENT IS TO DISPLAY THE QUANTUM SYSTEM

COMPONENTS AND ECOSYSTEM PARTS ONLY. All EcoSystem ballast and modules should be wired to the loop that is shown. This is required for Lutron database programming purposes.

Placement of the XPJ, BMJ and BMF modules are show for illustrative purposes only and can be placed anywhere within the rooms/loops.

LUTRON LAYOUT IS BASED UPON:

Drawing By: WMA Consulting Engineers Sheet No: E-3.04 Dated: 2/16/10

Drawing Not To Scale

**IMPORTANT NOTE REGARDING SENSOR PLACEMENT**

THE OCCUPANCY SENSORS & DAYLIGHT SENSORS ON THIS

ECOSYSTEM LOOP LAYOUT WERE NOT PLACED BY LUTRON. THIS

ECOSYSTEM LOOP LAYOUT ONLY SHOWS THE CONNECTION OF

THE SENSORS TO THE APPROPRIATE ECOSYSTEM COMPONENT.

THE ACTUAL LOCATIONS OF THE SENSORS SHOULD BE

DETERMINED BY FOLLOWING THE LUTRON SPECIFICATION SHEETS

AND THE INSTALLATION INSTRUCTIONS.

NOTE TO CONTRACTOR:

LUTRON WILL PROGRAM THE QUANTUM

SYSTEM PER THESE LOOP LAYOUTS. IF

THE SYSTEM CANNOT BE WIRED AS

SHOWN, PLEASE CONTACT LUTRON.

ECOSYSTEM LOOP CONTROLS / MODULES

EcoSystem ballast / module address number.

All ballast / modules to be wired back to the lighting management hub (LMH-X-X) noted on the loop layout.

Lutron Part: C5-XPJ-16A: EcoSystem Switching Power Module for Non-Dim Loads.

Allows integration of any load type into the EcoSystem Bus for up to 16A of load. Loads controlled through this module will not be dimmed.

Lutron Part: C5-BMJ-16A: EcoSystemTM Dimming Power Module for 3-wire Lutron Dimming Ballasts.

Allows integration of any Lutron Eco-10, Hi-Lume and compact SE ballasts into the EcoSystem Loop for up to 16A of load.

Lutron Part: EC-DIR-WH: Daylight Sensor.

This daylight sensor is designed specifically to work with Lutron's EcoSystemTM ballasts and modules to implement daylight harvesting. Requires 4 #22 AWG wires.

Lutron Part: LOS-CDT-XXXX-WH: Dual Technology Ceiling Mount Sensor. Wire to the closest EcoSystem ballast / module in the same room without the use of a power pack. Requires 3 #22 AWG wires.

(45 Ballast Addresses)

LMH-2-1

Ecosystem Loop #7 (45 Ballast Addresses)

Project Number:

Drawn By:

Drawing Revision:

Drawing Date:

Sheet:

Lutron Electronics Co., Inc.

7200 Suter Road | Coopersburg, PA 18036 | USA

(610) 282-3800 | fax: (610) 282-1146

US Court House Hammond, IN

88732

KSK

2ELL1

11/18/10

Atrium

QUANTUM

ECOSYSTEM LOOP LAYOUT

THIS DRAWING IS NOT TO BE USED FOR GENERAL BUILDING WIRING

PURPOSES. ITS INTENT IS TO DISPLAY THE QUANTUM SYSTEM

COMPONENTS AND ECOSYSTEM PARTS ONLY. All EcoSystem ballast and modules should be wired to the loop that is shown. This is required for Lutron database programming purposes.

Placement of the XPJ, BMJ and BMF modules are show for illustrative purposes only and can be placed anywhere within the rooms/loops.

LUTRON LAYOUT IS BASED UPON:

Drawing By: WMA Consulting Engineers Sheet No: E-3.04 Dated: 2/16/10

Drawing Not To Scale

**IMPORTANT NOTE REGARDING SENSOR PLACEMENT**

THE OCCUPANCY SENSORS & DAYLIGHT SENSORS ON THIS

ECOSYSTEM LOOP LAYOUT WERE NOT PLACED BY LUTRON. THIS

ECOSYSTEM LOOP LAYOUT ONLY SHOWS THE CONNECTION OF

THE SENSORS TO THE APPROPRIATE ECOSYSTEM COMPONENT.

THE ACTUAL LOCATIONS OF THE SENSORS SHOULD BE

DETERMINED BY FOLLOWING THE LUTRON SPECIFICATION SHEETS

AND THE INSTALLATION INSTRUCTIONS.

NOTE TO CONTRACTOR:

LUTRON WILL PROGRAM THE QUANTUM

SYSTEM PER THESE LOOP LAYOUTS. IF

THE SYSTEM CANNOT BE WIRED AS

SHOWN, PLEASE CONTACT LUTRON.

ECOSYSTEM LOOP CONTROLS / MODULES

EcoSystem ballast / module address number.

All ballast / modules to be wired back to the lighting management hub (LMH-X-X) noted on the loop layout.

Lutron Part: C5-XPJ-16A: EcoSystem Switching Power Module for Non-Dim Loads.

Allows integration of any load type into the EcoSystem Bus for up to 16A of load. Loads controlled through this module will not be dimmed.

Lutron Part: C5-BMJ-16A: EcoSystemTM Dimming Power Module for 3-wire Lutron Dimming Ballasts.

Allows integration of any Lutron Eco-10, Hi-Lume and compact SE ballasts into the EcoSystem Loop for up to 16A of load.

Lutron Part: EC-DIR-WH: Daylight Sensor.

This daylight sensor is designed specifically to work with Lutron's EcoSystemTM ballasts and modules to implement daylight harvesting. Requires 4 #22 AWG wires.

Lutron Part: LOS-CDT-XXXX-WH: Dual Technology Ceiling Mount Sensor. Wire to the closest EcoSystem ballast / module in the same room without the use of a power pack. Requires 3 #22 AWG wires.

TAG LOCATION SERVICE HP VOLTS PH HZ MANUFACTURER REMARKS

VFD-5.1 LEVEL 5 MECHANICAL COOLING TOWER 15 480 3 60 EATON CUTLER-HAMMER 1,2,3,4

VFD-5.2 LEVEL 5 MECHANICAL COOLING TOWER 15 480 3 60 EATON CUTLER-HAMMER 1,2,3,4

VFD-5.3 LEVEL 5 MECHANICAL COOLING TOWER 15 480 3 60 EATON CUTLER-HAMMER 1,2,3,4

VFD-LL.1 LOWER LEVEL MECH RM CHW PUMP P-1 15 480 3 60 EATON CUTLER-HAMMER 2,3,4

VFD-LL.4 LOWER LEVEL MECH RM CHW PUMP P-4 15 480 3 60 EATON CUTLER-HAMMER 2,3,4

VFD-LL.6 LOWER LEVEL MECH RM CHW PUMP P-6 15 480 3 60 EATON CUTLER-HAMMER 2,3,4

VFD-LL.7 LOWER LEVEL MECH RM CHW PUMP P-7 15 480 3 60 EATON CUTLER-HAMMER 2,3,4

REMARKS:

1. VFD WITH BYPASS FURNISHED BY COOLING TOWER MANUFACTURER

2. FURNISHED BY DIVISION 23 AND INSTALLED BY DIVISION 26.

3. COORDINATE EXACT LOCATION FOR NEW VFD IN FIELD. MAINTAIN MANUFACTURER'S RECOMMENDED CLEARANCES.

4. TEMPERATURE CONTROL CONTRACTOR SHALL EXTEND EXISTING EMS TO PROVIDE HARD-WIRED INTERFACE FOR

START-STOP, MODULATION, ALARM AND STATUS

VARIABLE FREQUENCY DRIVE SCHEDULE (VFD)

Insert from: "As-Built Consolidated.pdf"
IN0300ZZ-RIN00241-Cover
IN0300ZZ-RIN00241-G-001
IN0300ZZ-RIN00241-G-002
IN0300ZZ-RIN00241-AS-001
IN0300ZZ-RIN00241-A-100
IN0300ZZ-RIN00241-A-101
IN0300ZZ-RIN00241-A-104
IN0300ZZ-RIN00241-A-107
IN0300ZZ-RIN00241-A-109
IN0300ZZ-RIN00241-A-200
IN0300ZZ-RIN00241-A-203
IN0300ZZ-RIN00241-A-205
IN0300ZZ-RIN00241-M-000
IN0300ZZ-RIN00241-M-100
IN0300ZZ-RIN00241-M-100A
IN0300ZZ-RIN00241-M-105
IN0300ZZ-RIN00241-M-106
IN0300ZZ-RIN00241-E-000
IN0300ZZ-RIN00241-E-001
IN0300ZZ-RIN00241-E-002
IN0300ZZ-RIN00241-E-003
IN0300ZZ-RIN00241-E-200
IN0300ZZ-RIN00241-E-205
IN0300ZZ-RIN00241-E-206
IN0300ZZ-RIN00241-E-302
2nd Floor Loop
IN0300ZZ-RIN00241-E-304
4th Floor Loop
Atruim Loop