Cooling Tower.xlsx

XLSX spreadsheet 347 KB Posted

Attached to
Operations & Mechanical Maintenance Services Federal contract opportunity
Solicitation number
GS05P12SID0056
Issued by
General Services Administration Public Buildings Service

About this file

Hammond Cooling Tower

View the file

Other files for this federal contract opportunity

Other files attached to Operations & Mechanical Maintenance Services, newest first.
File Type Posted
Hammond Drawings.pdf PDF
Hammond CH Equipment.pdf PDF
EC10E1142 - Hammond Courthouse Final O M —
Hammond TENANT Equipment.pdf PDF
Hammond TENANT Equipment1.pdf PDF
Atrium Beam Detectors.pdf PDF
South Bend HVAC Schedules.pdf PDF
South Bend Inv. Tenant Equipment.pdf PDF
AMD 002.pdf PDF
Hammond Inv.pdf PDF
South Bend-Equip-Inventory 3-2012.pdf PDF
SIGN-IN SHEET.pdf PDF
AMD 001.pdf PDF
Indiana O M.pdf PDF
Show all 14

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

Sheet6

Sheet5

Sheet4

Sheet12CoolingTowers

Spec Section 15711 & 15545COOLING TOWERS
TAGLOCATIONMFR.ELECTRIC
CT-1ACOOLING TOWER 1ARoof (North)
CT-1BCOOLING TOWER 1BRoof (North)
CT-1CCOOLING TOWER 1CRoof (North)
BALTIMORE AIRCOIL460v/3ph
TYPE: INDUCED DRAFTSERIES 3000
MIN TOTAL L/S: 127.6
MIN EWT CENT: 35.75
MIN LWT CENT: 29.44
AMB WBT CENT: 25.55
MAX PD MM H20: 12.2
STAINLESS STEEL BASIN WITH REMOTE SUMP, 10' - 2" HIGH.
VIBRATION ISOLATION/DEFLECTION, MM: TYPE B / 100
CELLS: 3
FANS: 3: 15hp, 3ph, 60 hz, 460volt
KW OF EACH FAN: 11.18
TOTAL OPERATING WEIGHT KG: 27,240
HOH Chemical water treatmentAutorol 490CTC Microprocessor control panel
1" Autotrol turbine flow sensorHOH SC-10S ByPass feeder
LMI A151-82S Chemical pump
HOH 2020 Injection AssemblyHOH C-452 Liquid Cooling water treatment
HOH BromiCide-T Solid Biocide
HOH A-315 Liquid Biocide
The below ARRA work was completed in 2010

tenantAC

HAMMOND SUPPLEMENTAL TENANT AC UNITS
Type/size of A/C unitModel NumberArea ServedLocation of condensing UnitPanelboard Location of AC Power
Liebert split unit -1 tonMMD14W2POEOOU.S.A server roomceiling(water cooled)1st floor NW Elec. Closet
Liebert slit unit -2 tonMMD24EP00DOU.S.M.S. command roomTop of SAHU DuctLL SE Elec. Closet
Sanyo split unit -2 tonC2432AProbation server roomTop of AHU-1 DuctLL NE Elec. Closet
MovinCool self contained - 2 tonOffice Pro 24U.S.D.C. server roomCeiling of U.S.D.C. Server2nd floor Elec. Closet

Existing 5" Tube

Stock

Added 5" Tube

Stock

Brock Construction

925 Highland Ave.

Thornton, IL 60476

23840 W Industrial Dr. S

Plainfield IL, 60585

(815) 609-0250

Hammond Federal Courthouse ARRA Project # RIN000241

Proposed CoolingTower

Layout

Drawing- B.Newell

Approval- B. Kirwan

Kirwan Job# 18659

Date March 15, 2010 tower.vsd

Page-1 image1.emf