FCSI C206.pdf
PDF 564 KB Posted
- Attached to
- Fisk Chapel Site Improvements
- Solicitation number
- Not on record
- Issued by
- Monmouth County, New Jersey
About this file
This document is a detailed technical drawing (C206) by The Goldstein Partnership Architects for the Fisk Chapel Site Improvements project located at 38 Fisk Street in Fair Haven, New Jersey. The drawing specifically focuses on proposed parking lot details, featuring a comprehensive 3-rail fence section and elevation with precise measurements and construction specifications. The design includes detailed technical specifications for fence installation, including post spacing, footing dimensions, concrete strength requirements (4000 PSI), and fencing infill using Master Halco Prism 3D rectangular mesh.
The drawing provides extensive technical details for fence construction, including specific measurements such as 95" rail length, approximate rail weight of 73 lbs, and a 96" center-to-center post configuration. The fence footing is specified to be a minimum of 30 inches deep or extending to the frost line, with a 12-inch diameter concrete hole. The technical drawing is part of a larger project by Frank H. Lehr Associates (site & civil engineers), and includes contributions from multiple engineering disciplines, including mechanical, electrical, structural, and technology consultants, with the drawing dated 02/01/25 and created by Richard J. Adelsohn, a New Jersey Professional Engineer.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| ReferenceDrawingsComplete.pdf | ||
| FCSI C205.pdf | ||
| FCSI C208.pdf | ||
| FCSI C204.pdf | ||
| FCSI E-1.pdf | ||
| FCSI C207.pdf | ||
| FCSI C201.pdf | ||
| FCSI C202.pdf | ||
| FCSI C203.pdf | ||
| FCSI C209.pdf | ||
| FCSI Spec Book - Complete.pdf |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET OF
TH
E
G O
LD
ST
EI
N
P A
R
TN
ER
SH
IP
AR
C H
IT
EC
TS
VA
LL
EY
S
TR
EE
T, S U
IT
E
0, M
AP
LE
W
O O
D , N
J
O
FC
: 9
-7
-4
DRAWING NUMBER
THIS DRAWING IS
INCOMPLETE UNLESS
CONTRACT DOCUMENTS.
USED WITH ALL OTHER
C O
PY
R
IG
H
T
B
Y
TH
E G
O
LD
ST
EI
N P
AR
TN
ER
SH
IP
AL
L
R
IG
H
TS
R
ES
ER
VE
D
D
ES
IG
N
ED
: r ja C
KD
: R
JA
SC
AL
E:
A S
N O
TE
D
D
AT
E:
2/
/2
W W
W .G
O
LD
ST
EI
N -A
R C
H
IT
EC
TS
.C O
M
FI
SK
C H
A
PE
L
SI
TE
IM
PR
O
VE
M
EN
TS
B O
R O
U G
H O
F
FA
IR
H
A
VE
N
FR
A N
K H
. L
EH
R A
SS
O
C
IA
TE
S, SI
TE
C
IV
IL
E N
G
IN
EE
R
S
SO
U
TH
H
AR
R
IS
O N
S T.
E
AS
T O
R
AN
G E, N J
T:
(9
) 6
-2
F:
(9
) 6
-6
O M
D
EX
, I N
C
M
EC
H
AN
IC
AL
E
LE
C
TR
IC
AL
E
N G
IN
EE
R S
C
R O
SS
A
VE
. M
ID
LA
N D
P
AR
K, N
J
T:
(2
) 4
-0
F
1)
-0
A
LL
A N
K
LE
IN
, P
E.
ST
R U
C
TU
R
AL
E N
G
IN
EE
R
S
R
O U
TE
W
ES
T, M O
U N
TA
IN
SI
D
E, N
J
O
FC
: 9
-2
-8
LO
R
IN
G
C O
N
SU
LT
IN
G E
N G
IN
EE
R S, TE
C
H N
O
LO
G Y
C O
N
SU
LT
AN
TS
AL
EX
AN
D
ER
P
AR
K, S
U
IT
E
0, P
R
IN
C
ET
O N
, N J
T:
(6
) 7
-6
F:
(6
) 7
-6
RI
CH
AR
D J.
A
DE
LS
O
HN
, P
E, P
P, C
M E
F
IS
K
ST
R
EE
T
BL
O
C K
L O
T
FA
IR
H
AV
EN
, N
J
N J
PR
O
FE
SS
IO
N
AL
E
N G
IN
EE
R N
J
LI
C
EN
SE
N
O . G
E3
FH
LA
P
R O
J N
O . 9
6.
c
6.
dw g rja
/2
6/
:5
PM
PR
O
PO
SE
D
PA
R
KI
N G
L O
T D
ET
AI
LS
C206
95"5 1 /2"
5 3/4"
5 3 /4"
(4) #3
REBAR
2 1/4"
5 1 /2"
2 3 /4"
1 3 /8"
FOOTING
POST
3 RAIL FENCE SECTION 3 RAIL 8 FT. SPACING FENCE ELEVATION
95" RAIL APPROX WEIGHT 73 LBS.
FOOTING
RAIL SECTION
FOOTING
NATURAL GRADE
RAIL
POST
FOOTING
4000 PSI
CONC
POST
RAIL
2' 1'-
1/2
2'- 6"
4'
8'
2'- 6"
4'- 0 1
/4" 2'
6'- 3"
5 3/4"
1'- 0 1
/2" 5 3
/4" 9 1 /4" 5 3
/4" 9 1 /4" 5 3
/4" 2 3 /4"
1'
INFILL BETWEEN POSTS WITH MASTER HALCO PRISM 3D RECTANGULAR MESH
FENCING
STOP
FRONT VIEW
(90.5")
(7 2"
" M
IN
IM
UM
OR
T
O
FR
OS
T
LIN
E
(1 .6"
12" DIA
96" CENTER TO CENTER
HOLE
CONCRETE
C206
File details come from the government source that posted it. Updated .