About this file

This document is a detailed technical drawing (C206) by The Goldstein Partnership Architects for the Fisk Chapel Site Improvements project located at 38 Fisk Street in Fair Haven, New Jersey. The drawing specifically focuses on proposed parking lot details, featuring a comprehensive 3-rail fence section and elevation with precise measurements and construction specifications. The design includes detailed technical specifications for fence installation, including post spacing, footing dimensions, concrete strength requirements (4000 PSI), and fencing infill using Master Halco Prism 3D rectangular mesh.

The drawing provides extensive technical details for fence construction, including specific measurements such as 95" rail length, approximate rail weight of 73 lbs, and a 96" center-to-center post configuration. The fence footing is specified to be a minimum of 30 inches deep or extending to the frost line, with a 12-inch diameter concrete hole. The technical drawing is part of a larger project by Frank H. Lehr Associates (site & civil engineers), and includes contributions from multiple engineering disciplines, including mechanical, electrical, structural, and technology consultants, with the drawing dated 02/01/25 and created by Richard J. Adelsohn, a New Jersey Professional Engineer.

View the file

Other files

File Type Posted
ReferenceDrawingsComplete.pdf PDF
FCSI C205.pdf PDF
FCSI C208.pdf PDF
FCSI C204.pdf PDF
FCSI E-1.pdf PDF
FCSI C207.pdf PDF
FCSI C201.pdf PDF
FCSI C202.pdf PDF
FCSI C203.pdf PDF
FCSI C209.pdf PDF
FCSI Spec Book - Complete.pdf PDF
Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHEET OF

TH

E

G O

LD

ST

EI

N

P A

R

TN

ER

SH

IP

AR

C H

IT

EC

TS

VA

LL

EY

S

TR

EE

T, S U

IT

E

0, M

AP

LE

W

O O

D , N

J

O

FC

: 9

-7

-4

DRAWING NUMBER

THIS DRAWING IS

INCOMPLETE UNLESS

CONTRACT DOCUMENTS.

USED WITH ALL OTHER

C O

PY

R

IG

H

T

B

Y

TH

E G

O

LD

ST

EI

N P

AR

TN

ER

SH

IP

AL

L

R

IG

H

TS

R

ES

ER

VE

D

D

ES

IG

N

ED

: r ja C

KD

: R

JA

SC

AL

E:

A S

N O

TE

D

D

AT

E:

2/

/2

W W

W .G

O

LD

ST

EI

N -A

R C

H

IT

EC

TS

.C O

M

FI

SK

C H

A

PE

L

SI

TE

IM

PR

O

VE

M

EN

TS

B O

R O

U G

H O

F

FA

IR

H

A

VE

N

FR

A N

K H

. L

EH

R A

SS

O

C

IA

TE

S, SI

TE

C

IV

IL

E N

G

IN

EE

R

S

SO

U

TH

H

AR

R

IS

O N

S T.

E

AS

T O

R

AN

G E, N J

T:

(9

) 6

-2

F:

(9

) 6

-6

O M

D

EX

, I N

C

M

EC

H

AN

IC

AL

E

LE

C

TR

IC

AL

E

N G

IN

EE

R S

C

R O

SS

A

VE

. M

ID

LA

N D

P

AR

K, N

J

T:

(2

) 4

-0

F

1)

-0

A

LL

A N

K

LE

IN

, P

E.

ST

R U

C

TU

R

AL

E N

G

IN

EE

R

S

R

O U

TE

W

ES

T, M O

U N

TA

IN

SI

D

E, N

J

O

FC

: 9

-2

-8

LO

R

IN

G

C O

N

SU

LT

IN

G E

N G

IN

EE

R S, TE

C

H N

O

LO

G Y

C O

N

SU

LT

AN

TS

AL

EX

AN

D

ER

P

AR

K, S

U

IT

E

0, P

R

IN

C

ET

O N

, N J

T:

(6

) 7

-6

F:

(6

) 7

-6

RI

CH

AR

D J.

A

DE

LS

O

HN

, P

E, P

P, C

M E

F

IS

K

ST

R

EE

T

BL

O

C K

L O

T

FA

IR

H

AV

EN

, N

J

N J

PR

O

FE

SS

IO

N

AL

E

N G

IN

EE

R N

J

LI

C

EN

SE

N

O . G

E3

FH

LA

P

R O

J N

O . 9

6.

c

6.

dw g rja

/2

6/

:5

PM

PR

O

PO

SE

D

PA

R

KI

N G

L O

T D

ET

AI

LS

C206

95"5 1 /2"

5 3/4"

5 3 /4"

(4) #3

REBAR

2 1/4"

5 1 /2"

2 3 /4"

1 3 /8"

FOOTING

POST

3 RAIL FENCE SECTION 3 RAIL 8 FT. SPACING FENCE ELEVATION

95" RAIL APPROX WEIGHT 73 LBS.

FOOTING

RAIL SECTION

FOOTING

NATURAL GRADE

RAIL

POST

FOOTING

4000 PSI

CONC

POST

RAIL

2' 1'-

1/2

2'- 6"

4'

8'

2'- 6"

4'- 0 1

/4" 2'

6'- 3"

5 3/4"

1'- 0 1

/2" 5 3

/4" 9 1 /4" 5 3

/4" 9 1 /4" 5 3

/4" 2 3 /4"

1'

INFILL BETWEEN POSTS WITH MASTER HALCO PRISM 3D RECTANGULAR MESH

FENCING

STOP

FRONT VIEW

(90.5")

(7 2"

" M

IN

IM

UM

OR

T

O

FR

OS

T

LIN

E

(1 .6"

12" DIA

96" CENTER TO CENTER

HOLE

CONCRETE

C206

File details come from the government source that posted it. Updated .