4.7.2020 RFI Clarification.docx

DOCX document 13 KB Posted

Attached to
PRESSURE VESSEL
Solicitation number
FA9101-20-Q-0026
Issued by

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

4.7.2020- RFI Clarification

The RFQ package has been reviewed and noticed that the vessel does not have a manway. Per the ASME code, if the pressure vessel does not have the corrosion allowance, it can be built without a Manway; however, your design includes corrosion allowance and therefore, a Manway is necessary per the ASME code.

· Answer- A Manway is not needed.

File details come from the government source that posted it. Updated .